首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
PurposeTo present an overview of the status of medical physics in radiotherapy in China, including facilities and devices, occupation, education, research, etc.Materials and methodsThe information about medical physics in clinics was obtained from the 9-th nationwide survey conducted by the China Society for Radiation Oncology in 2019. The data of medical physics in education and research was collected from the publications of the official and professional organizations.ResultsBy 2019, there were 1463 hospitals or institutes registered to practice radiotherapy and the number of accelerators per million population was 1.5. There were 4172 medical physicists working in clinics of radiation oncology. The ratio between the numbers of radiation oncologists and medical physicists is 3.51. Approximately, 95% of medical physicists have an undergraduate or graduate degrees in nuclear physics and biomedical engineering. 86% of medical physicists have certificates issued by the Chinese Society of Medical Physics. There has been a fast growth of publications by authors from mainland of China in the top international medical physics and radiotherapy journals since 2018.ConclusionsDemand for medical physicists in radiotherapy increased quickly in the past decade. The distribution of radiotherapy facilities in China became more balanced. High quality continuing education and training programs for medical physicists are deficient in most areas. The role of medical physicists in the clinic has not been clearly defined and their contributions have not been fully recognized by the community.  相似文献   

2.
AimIn this study, an accuracy survey of intensity-modulated radiation therapy (IMRT) and volumetric arc radiation therapy (VMAT) implementation in radiotherapy centers in Thailand was conducted.BackgroundIt is well recognized that there is a need for radiotherapy centers to evaluate the accuracy levels of their current practices, and use the related information to identify opportunities for future development.Materials and methodsAn end-to-end test using a CIRS thorax phantom was carried out at 8 participating centers. Based on each center's protocol for simulation and planning, linac-based IMRT or VMAT plans were generated following the IAEA (CRP E24017) guidelines. Point doses in the region of PTVs and OARs were obtained from 5 ionization chamber readings and the dose distribution from the radiochromic films. The global gamma indices of the measurement doses and the treatment planning system calculation doses were compared.ResultsThe large majority of the RT centers (6/8) fulfilled the dosimetric goals, with the measured and calculated doses at the specification points agreeing within ±3% for PTV and ±5% for OARS. At 2 centers, TPS underestimated the lung doses by about 6% and spinal cord doses by 8%. The mean percentage gamma pass rates for the 8 centers were 98.29 ± 0.67% (for the 3%/3 mm criterion) and 96.72 ± 0.84% (for the 2%/2 mm criterion).ConclusionsThe 8 participating RT centers achieved a satisfactory quality level of IMRT/VMAT clinical implementation.  相似文献   

3.
AimTo evaluate the resources and techniques used in the irradiation of patients with breast cancer after lumpectomy or mastectomy and the status of implementation of new techniques and therapeutic schedules in our country.BackgroundThe demand for cancer care has increased among the Spanish population, as long as cancer treatment innovations have proliferated. Radiation therapy in breast cancer has evolved exponentially in recent years with the implementation of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, image guided radiotherapy and hypofractionation.Material and MethodsAn original survey questionnaire was sent to institutions participating in the SEOR-Mama group (GEORM). In total, the standards of practice in 969 patients with breast cancer after surgery were evaluated.ResultsThe response rate was 70% (28/40 centers). In 98.5% of cases 3D conformal treatment was used. All the institutions employed CT-based planning treatment. Boost was performed in 56.4% of patients: electrons in 59.8%, photons in 23.7% and HDR brachytherapy in 8.8%. Fractionation was standard in 93.1% of patients. Supine position was the most frequent. Only 3 centers used prone position. The common organs of risk delimited were: homolateral lung (80.8%) and heart (80.8%). In 84% histograms were used. An 80.8% of the centers used isocentric technique. In 62.5% asymmetric fields were employed. CTV was delimited in 46.2%, PTV in 65% and both in 38.5%. A 65% of the centers checked with portal films. IMRT and hypofractionation were used in 1% and in 5.5% respectively.ConclusionIn most of centers, 3D conformal treatment and CT-based planning treatment were used. IMRT and hypofractionation are currently poorly implemented in Spain.  相似文献   

4.
Background and purposeThe Medical Physics Division of the Portuguese Physics Society (DFM_SPF) in collaboration with the IAEA, carried out a national auditing project in radiotherapy, between September 2011 and April 2012. The objective of this audit was to ensure the optimal usage of treatment planning systems. The national results are presented in this paper.Material and methodsThe audit methodology simulated all steps of external beam radiotherapy workflow, from image acquisition to treatment planning and dose delivery. A thorax CIRS phantom lend by IAEA was used in 8 planning test-cases for photon beams corresponding to 15 measuring points (33 point dose results, including individual fields in multi-field test cases and 5 sum results) in different phantom materials covering a set of typical clinical delivery techniques in 3D Conformal Radiotherapy.ResultsAll 24 radiotherapy centers in Portugal have participated. 50 photon beams with energies 4–18 MV have been audited using 25 linear accelerators and 32 calculation algorithms.In general a very good consistency was observed for the same type of algorithm in all centres and for each beam quality.ConclusionsThe overall results confirmed that the national status of TPS calculations and dose delivery for 3D conformal radiotherapy is generally acceptable with no major causes for concern. This project contributed to the strengthening of the cooperation between the centres and professionals, paving the way to further national collaborations.  相似文献   

5.
PurposeThe aim of this study was to measure the occupational exposure using active personal dosimeters (APD) in the PET/CT department at different stages of the operation chain i.e. radiopharmaceutical arrival, activity preparation, dispensing, injection, patient positioning, discharge and compare the radiation exposure doses received using two automatic injection/infusion systems. This paper also reflects optimization processes that were performed to reduce occupational exposure.MethodsMeasured APD data were analysed for medical physicists, radiology technologists and administrative staff from 2014 till 2018. For dispensing and injecting 18F-FDG, the automatic infusion/injection system IRIDE (Comecer, Italy) or the automatic fractionator ALTHEA (Comecer, Italy) with wireless injection system WIS (Comecer, Italy) were used. Radiation exposure optimization methods were applied during the data collection period (installation of the transport port, patient management, APD alarm threshold and etc.).ResultsRadiology technologists who perform injection procedures, regardless of the automatic infusion system, received the highest radiation exposure dose. The average doses to the radiology technologists per one study were 1.72 ± 0.33 μSv and 1.16 ± 0.11 μSv with ALTHEA/WIS and IRIDE system, respectively. The average dose for accompanying the patient to the PET/CT scanner and scan procedure was 0.52 ± 0.07 μSv. For the medical physicists, the average dose was 0.29 ± 0.09 µSv. The measured dose for administrative staff was 0.30 ± 0.15 μSv.ConclusionsOccupational exposure can be effectively optimized by different means including staff monitoring with APD, implementation of radiation safety culture and the usage of automatic infusion systems.  相似文献   

6.
PurposeIn this article we report on the results of a survey of physics plan review practices conducted by the Cancer Care Ontario Communities of Practice and the variations in practice between and within centers.MethodsThe medical physicists at each center worked together to complete the survey and submit a single response for that center. A 4-point Likert scale, used to report the variation in practice at each center, was quantified into two parameters: “Intra-center variation”, the distribution of responses within the center, and “Variation between centers”, the difference between the center’s response and the provincial mean. These metrics were correlated with center characteristics to identify factors that impacted on variations in practice.ResultsBolus and heterogeneity correction were the only two items checked by all physicists in all centers. In more than half of the centers, image registration and DVH binning are not likely checked by physics. A significant difference in the variation between centers is observed for centers that used a single vendor’s products. Centers that used an official checklist indicated higher levels and a wider range of Intra-center variation. Higher workload did not affect the variation in checking patterns between physicists in the same center.ConclusionsThe effect of a center’s resources on their checking practice suggest that local environment and workflow be accounted for when implementing TG275 guidelines. The observation that standardized checklists did not reduce checking variability point to the importance of following the checklist development guidelines in MPPG4 to avoid ineffective checklists.  相似文献   

7.
AimDescribe the results of the first national census of radiotherapy in Mexico in order to make a situational diagnosis of radiotherapy availability, offer more accurate information to radiation oncologists, and promote an adequate scientific based investment for the country.BackgroundAccording to the Organisation for Economic Co-operation and Development (OECD), the density of radiotherapy (RT) machines per million habitants in Mexico is approximately 1.7−1.8. Other international organizations such as DIRAC-IAEA report 1.15 per million habitants. National organizations collect data indirectly and previous surveys had a low accrual rate (32.5%). Therefore, a precise census is required.Material and methodsThe Mexican Radiation Oncology Certification Board (CMRO for its acronym in Spanish) conducted a nationwide census from January through November 2019. Gathered information was combined with CMRO database for sociodemographic information and human resources.ResultsThe study included 103 RT centers [95.1% answered the survey], with a median of 2 centers by state (ranging from 0 in Tlaxcala to 20 in Mexico City) and with a report of only 1 center in 11 states (34.4%). Fifty-six (54.3%) of the centers are public. Fourteen centers (13.6%) have residency-training programs. The total number of RT machines is 162 [141 clinical and linear accelerators (87%) and 21 radionuclide units (13%)] with a median of 3 machines by state (0 in Tlaxcala to 46 in Mexico City) and with ≤3 machines in 18 states (56.25%). The overall calculated density of RT machines per million habitants is 1.32, varying from 0 in Tlaxcala to 5.16 in Mexico City. The density of linear and clinical accelerators per million population is 1.19. The total number of brachytherapy units is 66, with a median of 1 center with brachytherapy unit per state and 29 states with ≤3 centers with a brachytherapy unit (90.6%). Thirty-seven brachytherapy units (56.1%) have automated afterload high-dose rate. The overall rate of brachytherapy units per million inhabitants is 0.55, varying from 0 in 5 states (15.6%), 0.1-0.49 in 8 states (25%), 0.5–0.99 in 13 states (40.6%), 1–1.49 in 5 states (15.6%) and 1.5–1.99 in Mexico City (3.1%). The Mexican CMRO has 368 radiation oncologists certified (99 women and 269 men), of whom only 346 remain as an active part of Mexico's workforce.ConclusionsThis is the first time the CMRO conducts a national census for a radiotherapy diagnostic situation in Mexico. The country currently holds a density of clinical and linear accelerators of 1.19 per million habitants. Brachytherapy density is 0.55 devices per million habitants, and 57% of radiotherapy centers have brachytherapy units.  相似文献   

8.
PurposeESTRO-EFOMP intend to update the core curriculum (CC) for education and training of medical physicists in radiotherapy in line with the European Commission (EC) guidelines on Medical Physics Experts (MPE), the CanMEDS methodology and recent developments in radiotherapy. As input, a survey of the current structure of radiotherapy MPE national training schemes (NTS) in Europe was carried out.MethodsA 35-question survey was sent to all European medical physics national societies (NS) with a focus on existence of an NTS, its format and duration, required entry-level education, and financial support for trainees.ResultsTwenty-six of 36 NS responded. Twenty had an NTS. Minimum required pre-training education varied from BSc in physics or related sciences (5/2) to MSc in medical physics, physics or related sciences (6/5/2) with 50–210 ECTS in fundamental physics and mathematics. The training period varied from 1 to 5 years (median 3 years with 50% dedicated to radiotherapy). The ratio of time spent on university lectures versus hospital training was most commonly 25%/75%. In 14 of 20 countries with an NTS, a research project was mandatory. Residents were paid in 17 of 20 countries. The recognition was mostly obtained by examination. Medical physics is recognised as a healthcare profession in 19 of 26 countries.ConclusionsThe NTS entrance level, duration and curriculum showed significant variations. This survey serves to inform the design of the updated CC to define a realistic minimum training level for safe and effective practice aiming at further harmonization in line with EC guidelines.  相似文献   

9.
BackgroundBreast cancer is the most frequent cancer in women in France. Its management has evolved considerably in recent years with a focus on reducing iatrogenic toxicity. The radiotherapy indications are validated in multidisciplinary consultation meetings; however, questions remain outstanding, particularly regarding hypofractionated radiotherapy, partial breast irradiation, and irradiation of the internal mammary chain and axillary lymph node area.Materials and methodsAn online survey was sent to 47 heads of radiotherapy departments in France. The survey consisted of 22 questions concerning indications for irradiation of the supraclavicular, internal mammary and axillary lymph node areas; irradiation techniques and modalities; prescribed doses; and fractionation.ResultsTwenty-four out of 47 centers responded (response rate of 51%). This survey demonstrated a wide variation in the prescribed dose regimen, monoisocentric radiotherapy, and indications of irradiation of the lymph node areas.ConclusionThis survey provides insight into the current radiotherapy practice for breast cancer in France. It shows the need to standardize practices.  相似文献   

10.
PurposeThe present work aims to guide the physicist in order to start automated planning for the VMAT treatment of glioblastoma multiforme (GBM) by giving a recipe that was set up and tested during a long-term (two years) evaluation.MethodsAn automatic technique in AutoPlanning module of the Pinnacle3 (Philips Medical Systems, Fitchburg, WI) treatment planning system was created and validated by comparing dose distributions of automatic plans (APs) and manual plans (MPs) and by performing a blind AP-MP comparison on a cohort of 20 patients. Automatic technique was then applied to 145 patients and failures were recorded i.e. the number of times for which dose distributions produced by the automatic module were not suitable for treatment.ResultsEach of the 20 APs considered in the validation step was clinically acceptable and proved to be better (15 cases) or equal (5 cases) respect to MPs. A statistically significant improvement in brain stem, optic pathways, cochleae, pituitary gland and scalp sparing was observed for APs, while no statistically significant differences were recorded in target coverage or plan parameters. For only 5 cases out of the 145 plans the operator intervention was needed in order to obtain a clinical acceptable plan, while for the remaining 140 plans the automatic created solution was suitable.ConclusionsA straightforward automatic procedure has been created and tested in our clinic. The AutoPlanning technique proposed represents a reliable tool to improve treatment planning efficiency and the recipe, here presented, could be simply imported to every radiotherapy center.  相似文献   

11.

Background and purpose

To evaluate the current status of radiotherapy facilities, staffing, and equipment, treatment and patients in Poland for the years 2005–2011 following implementation of the National Cancer Programme.

Methods

A survey was sent to the radiotherapy centres in Poland to collect data on available equipment, staffing, and treatments in the years 2005–2011.

Results

In 2011, 76,000 patients were treated with radiotherapy at 32 centres vs. 63,000 patients at 23 centres in 2005. Number of patients increased by 21%. In 2011, there were 453 radiation oncologists – specialists (1 in 168 patients), 325 medical physicists (1 in 215 patients), and 883 radiotherapy technicians (1 in 86 patients) vs. 320, 188, and 652, respectively, in 2005. The number of linear accelerators increased by 60%, from 70 units in 2005 to 112 in 2011. The current linac/patient ratio in Poland is 1 linac per 678 patients. Waiting times from diagnosis to the start of treatment has decreased.

Conclusion

Compared to 2005, there are more treatment facilities, more and better equipment (linacs), and more cancer care specialists. There are still large differences between the 16 Polish provinces in terms of equipment availability and ease of access to treatment. However, radiotherapy services in Poland have improved dramatically since the year 2005.  相似文献   

12.
13.
BackgroundUnbiased analysis of the impact of adaptive radiotherapy (ART) is necessary to evaluate dosimetric benefit and optimize clinics’ workflows. The aim of the study was to assess the need for adaptive radiotherapy (ART) in head and neck (H&N) cancer patients using an automatic planning tool in a retrospective planning study.Materials and methodsThirty H&N patients treated with adaptive radiotherapy were analysed. Patients had a CT scan for treatment planning and a verification CT during treatment according to the clinic’s protocol. Considering these images, three plans were retrospectively generated using the iCycle tool to simulate the scenarios with and without adaptation: 1) the optimized plan based on the planning CT; 2) the optimized plan based on the verification CT (ART-plan); 3) the plan obtained by considering treatment plan 1 re-calculated in the verification CT (non-ART plan). The dosimetric endpoints for both target volumes and OAR were compared between scenarios 2 and 3 and the SPIDERplan used to evaluate plan quality.ResultsThe most significant impact of ART was found for the PTVs, which demonstrated decreased D98% in the non-ART plan. A general increase in the dose was observed for the OAR but only the spinal cord showed a statistical significance. The SPIDERplan analysis indicated an overall loss of plan quality in the absence of ART.ConclusionThese results confirm the advantages of ART in H&N patients, especially for the coverage of target volumes. The usage of an automatic planning tool reduces planner-induced bias in the results, guaranteeing that the observed changes derive from the application of ART.  相似文献   

14.
BackgroundThere is a continuous and dynamic discussion on artificial intelligence (AI) in present-day society. AI is expected to impact on healthcare processes and could contribute to a more sustainable use of resources allocated to healthcare in the future. The aim for this work was to establish a foundation for a Swedish perspective on the potential effect of AI on the medical physics profession.Materials and methodsWe designed a survey to gauge viewpoints regarding AI in the Swedish medical physics community. Based on the survey results and present-day situation in Sweden, a SWOT analysis was performed on the implications of AI for the medical physics profession.ResultsOut of 411 survey recipients, 163 responded (40%). The Swedish medical physicists with a professional license believed (90%) that AI would change the practice of medical physics but did not foresee (81%) that AI would pose a risk to their practice and career. The respondents were largely positive to the inclusion of AI in educational programmes. According to self-assessment, the respondents’ knowledge of and workplace preparedness for AI was generally low.ConclusionsFrom the survey and SWOT analysis we conclude that AI will change the medical physics profession and that there are opportunities for the profession associated with the adoption of AI in healthcare. To overcome the weakness of limited AI knowledge, potentially threatening the role of medical physicists, and build upon the strong position in Swedish healthcare, medical physics education and training should include learning objectives on AI.  相似文献   

15.
BackgroundThe aim of the study was to identify strategies adopted by radiotherapy centres in low- and middle-income countries (LMICs) to mitigate the effects of COVID-19. Studies summarising COVID-19 mitigation strategies designed and implemented by radiotherapy centres in LMICs to avoid delays, deferrments and interruptions of radiotherapy services are lacking.Materials and methodsA systematic review was conducted and reported in accordance with the preferred reporting items for systematic review and meta-analysis guideline. Ovid Embase, Ovid MEDLINE and CINAHL were searched for peer-reviewed articles that reported measures adopted by radiotherapy centres in LMICs to reduce the risk of COVID-19. Information on different strategies were extracted from the included studies and textual narrative synthesis was conducted.ResultsOf 60 articles retrieved, eleven were included. Majority of the studies were conducted in China. Ten of the included studies employed a qualitative design. Four themes were identified: preparing and equipping staff; reinforcing infection prevention and control policies; strengthening coordination and communication; and maintaining physical distancing. Studies reported that radiotherapy centres had: formed COVID-19 response multidisciplinary team; maximised the use of telehealth; adjusted the layout of waiting areas; divided staff into teams; dedicated a room for isolating suspected cases; and adopted triage systems.ConclusionsLocal adaptation of established global strategies coupled with timely development of guidelines, flexibility and innovation have allowed radiotherapy leaders to continue to deliver radiotherapy services to cancer patients in LMICs during the COVID-19 crisis. Robust data collection must be encouraged in LMICs to provide an evidence-based knowledge for use in the event of another pandemic.  相似文献   

16.

Aim

This survey is performed to learn about the structure of radiotherapy in México.

Background

Radiation oncology practice is increasing because of the higher incidence of cancer. There is no published data about radiotherapy in México.

Materials and methods

A questionnaire was sent to the 83 registered centers in the database of the Mexican regulatory agency. One out of the 32 states has no radiotherapy. 27 centers from 14 states provided their answers.

Results

829 patients are treated annually with any radiotherapy modality in each center. Two centers have one cobalt machine, 7 have a cobalt and a linac and 10 have more than one linac. Five centers use 2D planning systems, 22 use 3D; 9, conventional simulators; 22, CT based simulation, and 1 center has no simulation. Most of the centers verify beams with films, electronic portal image devices and cone beam CTs are also used. Intensity modulated and image guided radiotherapy are performed in 5 states. Breast, prostate, cervix, lung, rectum and head and neck cancer are the six most common locations. There are 45 public and 38 private centers, 2 dedicated to children. Two gamma knife units, 5 Novalis systems, 1 tomotherapy and 2 cyberknife machines are working. All centers have at least one radiation oncologist, one physicist and one radiotherapist.

Conclusions

Definitive conclusions cannot be drawn from this limited feedback due to a low participation of centers. This survey about radiotherapy in Mexico shows the heterogeneity of equipment as well as medical and technical staff in the whole country.  相似文献   

17.
BackgroundThe aim is to find out how many radiation oncology centres treat biliary duct carcinoma (BDC), what treatments they offer and whether they would be interested in developing prospective trials.Materials and methodsA questionnaire was posted to all 220 Italian Radiation Oncology Centres. The survey consisted of 31 eligibility questions in a combination of multiple and forced choice formats addressing the following parameters: characteristics of the centre, numbers of BDC patients treated, treatment options, radiotherapy parameters (target definition, schedule, technique, dose constraints) and interest in developing future randomized trials.ResultsNo major differences emerged in BDC management, whatever the site, and whether it was resectable or not. Discrepancies in routine clinical practice were, however, observed with lack of agreement on expansion margins, dose constraints and treatment schedules for the stereotactic technique and palliative treatments.ConclusionsThe present survey attempted to fill the gaps in the role of radiotherapy in patients with BDC. Since lack of prospective randomized studies and disease rarity have mitigated against an evidence-based approach, patients with BDC should be enrolled in prospective studies. The above-mentioned results should also emphasize the need to combine analysis of treatment results from all Italian centres in order to create predictive models.  相似文献   

18.
《Médecine Nucléaire》2017,41(2):55-63
AimThe aim of this study was to assess lung scintigraphy practices in France for the diagnosis of acute pulmonary embolism, especially regarding the proportion of centers using single photon emission computed tomography (SPECT) rather than planar ventilation/perfusion (V/Q) imaging.Materials and methodsAn online survey composed of simple multiple-choice questions was distributed to the 210 french nuclear medicine departments in April and May 2014. The survey covered image acquisition, interpretation criteria for SPECT and planar images, and use of pseudoplanar images and radiopharmaceuticals. Departments were initially solicited by 2 sets of e-mails. They were subsequently contacted by phone. A single response per department was consolidated.ResultsTwo hundred nine responses were collected (participation rate: 99.5%). Sixty-seven percent of french centers indicated use of V/Q SPECT in routine practice. The first intention acquisition protocol was SPECT/CT in 34%, SPECT in 26% and V/Q planar in 34%. The most commonly used criteria for SPECT interpretation were those of the EANM (63%). Criteria used for planar interpretation were heterogeneous (EANM criteria, 39%; no standardized criteria, 28%; PIOPED, 23%). Eighty-three percent of centers used 99mTc aerosol and 17% 81mKr.ConclusionThis survey shows that SPECT has largely replaced planar imaging for PE diagnosis with lung scintigraphy. Acquisition protocols and interpretation criteria are inconsistent (especially for planar imaging).  相似文献   

19.
PurposeAutomated treatment planning is a new frontier in radiotherapy. The Auto-Planning module of the Pinnacle3 treatment planning system (TPS) was evaluated for liver stereotactic body radiation therapy treatments.MethodsTen cases were included in the study. Six plans were generated for each case by four medical physics experts. The first two planned with Pinnacle TPS, both with manual module (MP) and Auto-Planning one (AP). The other two physicists generated two plans with Monaco TPS (VM). Treatment plan comparisons were then carried on the various dosimetric parameters of target and organs at risk, monitor units, number of segments, plan complexity metrics and human resource planning time. The user dependency of Auto-Planning was also tested and the plans were evaluated by a trained physician.ResultsStatistically significant differences (Anova test) were observed for spinal cord doses, plan average beam irregularity, number of segments, monitor units and human planning time. The Fisher-Hayter test applied to these parameters showed significant statistical differences between AP e MP for spinal cord doses and human planning time; between MP and VM for monitor units, number of segments and plan irregularity; for all those between AP and VM. The two plans created by different planners with AP were similar to each other.ConclusionsThe plans created with Auto-Planning were comparable to the manually generated plans. The time saved in planning enables the planner to commit more resources to more complex cases. The independence of the planner enables to standardize plan quality.  相似文献   

20.
PurposeExternal dosimetry audits give confidence in the safe and accurate delivery of radiotherapy. The RTTQA group have performed an on-site audit programme for trial recruiting centres, who have recently implemented static or rotational IMRT, and those with major changes to planning or delivery systems.MethodsMeasurements of reference beam output were performed by the host centre, and by the auditor using independent equipment. Verification of clinical plans was performed using the ArcCheck helical diode array.ResultsA total of 54 measurement sessions were performed between May 2014 and June 2016 at 28 UK institutions, reflecting the different combinations of planning and delivery systems used at each institution. Average ratio of measured output between auditor and host was 1.002 ± 0.006. Average point dose agreement for clinical plans was −0.3 ± 1.8%. Average (and 95% lower confidence intervals) of gamma pass rates at 2%/2 mm, 3%/2 mm and 3%/3 mm respectively were: 92% (80%), 96% (90%) and 98% (94%). Moderately significant differences were seen between fixed gantry angle and rotational IMRT, and between combination of planning systems and linac manufacturer, but not between anatomical treatment site or beam energy.ConclusionAn external audit programme has been implemented for universal and efficient credentialing of IMRT treatments in clinical trials. Good agreement was found between measured and expected doses, with few outliers, leading to a simple table of optimal and mandatory tolerances for approval of dosimetry audit results. Feedback was given to some centres leading to improved clinical practice.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号