首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
PurposePancreatic tumor treatment dose distribution variations associated with supine and prone patient positioning were evaluated.MethodsA total of 33 patients with pancreatic tumors who underwent CT in the supine and prone positions were analyzed retrospectively. Gross tumor volume (GTV), planning target volume (PTV), and organs at risk (OARs) (duodenum and stomach) were contoured. The prescribed dose of 55.2 Gy (RBE) was planned from four beam angles (0°, 90°, 180°, and 270°). Patient collimator and compensating boli were designed for each field. Dose distributions were calculated for each field in the supine and prone positions. To improve dose distribution, patient positioning was selected from supine or prone for each beam field.ResultsCompared with conventional beam angle and patient positioning, D2cc of 1st-2nd portion of duodenum (D1-D2), 3rd-4th portion of duodenum (D3-D4), and stomach could be reduced to a maximum of 6.4 Gy (RBE), 3.5 Gy (RBE), and 4.5 Gy (RBE) by selection of patient positioning. V10 of D1-D2, D3-D4, and stomach could be reduced to a maximum of 7.2 cc, 11.3 cc, and 11.5 cc, respectively. D95 of GTV and PTV were improved to a maximum of 6.9% and 3.7% of the prescribed dose, respectively.ConclusionsOptimization of patient positioning for each beam angle in treatment planning has the potential to reduce OARs dose maintaining tumor dose in pancreatic treatment.  相似文献   

2.
We investigated the dose differences between robust optimization-based treatment planning (4DRO) and range-adapted internal target volume (rITV). We used 4DCT dataset of 20 lung cancer and 20 liver cancer patients, respectively, who had been treated with respiratory-gated carbon-ion pencil beam scanning therapy. 4DRO and rITV plans were created with the same clinical target volume (CTV) and organs at risk (OAR) contours. Four-dimensional dose distribution was calculated using deformable image registration. Dose metrics (e.g. D95, V20) were analyzed. Statistical significance was assessed by the Wilcoxon signed-rank test. For the lung cases, the mean CTV-D95 value for the rITV plan (=98.5%) was same as that for the 4DRO plan (=98.5%, P = 0.106), while the mean D95 value for the CTV + setup margin contour for the rITV plan (=98.2%) was higher than that for the 4DRO plan (95.2%, P < 0.001). For the liver cases, the mean CTV-D95 value for the rITV plan (=98.1%) was slightly lower than that for the 4DRO plan (=98.5%, P < 0.01), while the mean D95 value for the CTV + setup margin contour for the rITV plan (=98.0%) was higher than that for the 4DRO plan (94.1%, P < 0.001). For the doses to the organs at risk (OARs), the ipsilateral lung-V20/liver-V20 values for the rITV plan (=10.1%/19.7%) was significantly higher than that for the 4DRO plan (=8.6%/17.6, P < 0.001). Although the target coverage for 4DRO plan may be worse than that for rITV plan in the presence of the setup error, the 4DRO plan can improve OAR dose while preserving acceptable target dose coverage.  相似文献   

3.
ObjectivesTo investigate the dosimetric effect of air gaps under bolus on skin dose for left-sided post-mastectomy radiotherapy with loco regional involvement.MethodsEight patients were planned retrospectively with volume modulated arc therapy (VMAT) and conventional static Field-in-Field (FinF) methods. Three different setups were applied for the 5-mm bolus over the chest wall having 0, 5 or 10 mm air gap under the bolus. The dose calculation was performed using Monte Carlo (MC) simulation. In addition, Analytic Anisotropic Algorithm (AAA) was used to demonstrate the differences observed in clinical setting.ResultsThe investigated air gaps under the bolus had minimal effect on surface dose for FinF plans (relative difference ≤ 2.6%), whereas for VMAT plans the surface dose decreased 13.6% when compared to the case with no air gap. In both FinF and VMAT, the largest differences between AAA and MC were seen at the surface where AAA underestimated the dose by 1.5 Gy (p < 0.05) on average; while the dose in the target volume excluding the surface was relatively similar being on average 0.3 Gy (p > 0.05) larger with AAA than with MC calculations.ConclusionsThe surface dose was significantly lower with VMAT technique than with FinF technique. Possible air gaps under the bolus reduced the surface dose significantly further for VMAT but not for FinF treatments, which may have clinical impact on recurrence rate. AAA was shown to underestimate the surface dose when compared to MC calculation.  相似文献   

4.
BackgroundPrevious epidemiology studies reported that heavy metal/metalloid exposure is associated with the impairment of semen quality. However, it is still not clear whether the in vitro fertilization (IVF)/intracytoplasmic sperm injection (ICSI) treatment outcome will be affected after the heavy metal/metalloid exposure of the male partners.MethodsA prospective cohort study with a 2-year followed-up was conducted in a tertiary IVF center. A total of 111 couples undergoing IVF/ICSI treatment were initially recruited from November 2015 to November 2016. Male blood concentrations of heavy metal/metalloid including Ca, Cr, Mn, Fe, Ni, Cu, Zn, As, Se, Mo, Cd, Hg, and Pb were measured by inductively coupled plasma mass spectrometry, and the lab and pregnancy outcome data were followed up. The associations between male blood heavy metal/metalloid concentration and the clinical outcomes were analyzed by Poisson regression analysis.ResultsOur results showed that none of the heavy metal/metalloid of male partners we investigated are significantly associated with the oocyte fertilization and good embryo (P ≥ 0.05); however, antral follicle count (AFC) was a protective factor for the oocyte fertilization (RR: 1.07, 95 % CI: 1.04–1.10). The blood Fe concentration of the male partner was positively associated (P < 0.05) with pregnancy in the first fresh cycle (RR:170.93, 95 % CI: 4.13–7082.04), cumulative pregnancy (RR: 23.61, 95 % CI: 3.25–171.64) and cumulative live birth (RR: 36.42, 95 % CI: 1.21–1092.54). In the first frozen embryo cycles, pregnancy was significantly associated (P < 0.05) with the blood Mn (RR: 0.01, 95 % CI:0.00–0.11) and Se concentration (RR: 0.01, 95 % CI:8.25 E-5–0.47) and female age (RR: 0.86, 95 % CI:0.75–0.99); live birth was significantly associated (P < 0.05) with the blood Mn concentration (RR: 0.00, 95 % CI: 1.14E-7–0.51).ConclusionsOur results suggested that the higher male blood Fe concentration was positively associated with pregnancy in the fresh embryo transfer cycle, cumulative pregnancy, and cumulative live birth, whereas the higher male blood Mn and Se concentration were associated with lower chance of pregnancy and live birth in the frozen embryo transfer cycle. However, the underline mechanism of this finding still needs further investigation.  相似文献   

5.
PurposeTo assess the dosimetric impact of a patient positioning device for prone breast radiotherapy and assess the accuracy of a treatment planning system (TPS) in predicting this impact.MethodsBeam attenuation and build-up dose perturbations, quantified by ionization chamber and radiochromic film dosimetry, were evaluated for 3 components of the patient positioning device: the carbon fiber baseplate, the support cushions and the support wedge for the contralateral breast. Dose calculations were performed using the XVMC dose engine implemented in the Monaco TPS. All components were included during planning CT acquisition.ResultsBeam attenuation amounted to 7.57% (6 MV) and 5.33% (15 MV) for beams obliquely intersecting the couchtop–baseplate combination. Beams traversing large sections of the support wedge were attenuated by 12.28% (6 MV) and 9.37% (15 MV). For the support cushion foam, beam attenuation remained limited to 0.11% (6 MV) and 0.08% (15 MV) per centimeter thickness. A substantial loss of dose build-up was detected when irradiating through any of the investigated components. TPS dose calculations accurately predicted beam attenuation by the baseplate and support wedge. A manual density overwrite was needed to model attenuation by the support cushion foam. TPS dose calculations in build-up regions differed considerably from measurements for both open beams and beams traversing the device components.ConclusionsIrradiating through the components of the positioning device resulted in a considerable degradation of skin sparing. Inclusion of the device components in the treatment planning CT allowed to accurately model the most important attenuation effect, but failed to accurately predict build-up doses.  相似文献   

6.
7.
PurposeWe performed the first investigations, via measurements and Monte Carlo simulations on phantoms, of the feasibility of a new technique for synchrotron radiation rotational radiotherapy for breast cancer (SR3T).MethodsA Monte Carlo (MC) code based on Geant4 toolkit was developed in order to simulate the irradiation with the SR3T technique and to evaluate the skin sparing effect in terms of centre-to-periphery dose ratio at different energies in the range 60–175 keV. Preliminary measurements were performed at the Australian Synchrotron facility. Radial dose profiles in a 14-cm diameter polyethylene phantom were measured with a 100-mm pencil ionization chamber for different beam sizes and compared with the results of MC simulations. Finally, the dose painting feasibility was demonstrated with measurements with EBT3 radiochromic films in a phantom and collimating the SR beam at 1.5 cm in the horizontal direction.ResultsMC simulations showed that the SR3T technique assures a tumour-to-skin absorbed dose ratio from about 7:1 (at 60 keV photon energy) to about 10:1 (at 175 keV), sufficient for skin sparing during radiotherapy. The comparison between the results of MC simulations and measurements showed an agreement within 5%. Two off-centre foci were irradiated shifting the rotation centre in the horizontal direction.ConclusionsThe SR3T technique permits to obtain different dose distributions in the target with multiple rotations and can be guided via synchrotron radiation breast computed tomography imaging, in propagation based phase-contrast conditions. Use of contrast agents like iodinated solutions or gold nanoparticles for dose enhancement (DE-SR3T) is foreseen and will be investigated in future work.  相似文献   

8.
PurposeTo implement a daily CBCT based dose accumulation technique in order to assess ideal robust optimization (RO) parameters for IMPT treatment of prostate cancer.MethodsTen prostate cancer patients previously treated with VMAT and having daily CBCT were included. First, RO-IMPT plans were created with ± 3 mm and ± 5 mm patient setup and ± 3% proton range uncertainties, respectively. Second, the planning CT (pCT) was deformably registered to the CBCT to create a synthetic CT (sCT). Both daily and weekly sampling strategies were employed to determine optimal dose accumulation frequency. Doses were recalculated on sCTs for both ± 3 mm/±3% and ± 5 mm/±3% uncertainties and were accumulated back to the pCT. Accumulated doses generated from ± 3 mm/±3% and ± 5 mm/±3% RO-IMPT plans were evaluated using the clinical dose volume constraints for CTV, bladder, and rectum.ResultsDaily accumulated dose based on both ± 3mm/±3% and ±5 mm/±3% uncertainties for RO-IMPT plans resulted in satisfactory CTV coverage (RO-IMPT3mm/3% CTVV95 = 99.01 ± 0.87% vs. RO-IMPT5mm/3% CTVV95 = 99.81 ± 0.2%, P = 0.002). However, the accumulated dose based on ± 3 mm/3% RO-IMPT plans consistently provided greater OAR sparing than ±5 mm/±3% RO-IMPT plans (RO-IMPT3mm/3% rectumV65Gy = 2.93 ± 2.39% vs. RO-IMPT5mm/3% rectumV65Gy = 4.38 ± 3%, P < 0.01; RO-IMPT3mm/3% bladderV65Gy = 5.2 ± 7.12% vs. RO-IMPT5mm/3% bladderV65Gy = 7.12 ± 9.59%, P < 0.01). The gamma analysis showed high dosimetric agreement between weekly and daily accumulated dose distributions.ConclusionsThis study demonstrated that for RO-IMPT optimization, ±3mm/±3% uncertainty is sufficient to create plans that meet desired CTV coverage while achieving superior sparing to OARs when compared with ± 5 mm/±3% uncertainty. Furthermore, weekly dose accumulation can accurately estimate the overall dose delivered to prostate cancer patients.  相似文献   

9.
IntroductionThis study assessed the influence of High (H, 4.13%), Medium (M, 2.0%) and Low (L, 0.1%) doses of menthol on temperature perception and regulation, compared to a Placebo Condition (P).MethodSixteen participants underwent the aforementioned conditions on four separate days. During each test participants rested supine (Environmental conditions: 30 °C, 50% rh) for 30-min before 40 mL of L, M, H or P gel was applied to the anterior upper body, then rested 30-min thereafter. Primary measures included thermal sensation (TS), thermal comfort (TC), irritation (IRR), rectal temperature (Tre), and skin temperature (chest, forearm, thigh, calf), and EMG (trapezius, pectoralis major, sternocleidomastoid). The area under the curve (AUC) from minute 30 to 60 was compared between conditions using relevant non/parametric tests (alpha level = 0.05).ResultsA cooling trend in Tre was observed following Placebo gel application, but this significantly (p < 0.05) reversed into a heat storage response in M and H. Both TS and TC significantly differed by condition (p < 0.001) in a dose-dependent manner, with L, M, and H doses eliciting significantly cooler sensations and more discomfort than P (p < 0.05). Irritation significantly differed by condition (p < 0.01) in a dose-dependent manner, with L and M eliciting significantly greater irritation than P (p < 0.01). No other differences were observed.ConclusionsMenthol exerts perceptual and thermoregulatory effects independent of skin temperature. A menthol dose-dependent perceptual cooling effect was evident with possible saturation at the moderate dose. A dose-dependent alteration in deep body temperature was also evident.  相似文献   

10.
AimTo investigate the impact of Acuros XB (AXB) algorithm in the deep-inspiration breath-hold (DIBH) technique used for treatment of left sided breast cancer.BackgroundAXB may estimate better lung toxicities and treatment outcome in DIBH.Materials and MethodsTreatment plans were computed using the field-in-field technique for a 6 MV beam in two respiratory phases - free breathing (FB) and DIBH. The AXB-calculations were performed under identical beam setup and the same numbers of monitor units as used for AAA-calculation.ResultsMean Hounsfield units (HU), mass density (g/cc) and relative electron density were -782.1 ± 24.8 and -883.5 ± 24.9; 0.196 ± 0.025 and 0.083 ± 0.032; 0.218 ± 0.025 and 0.117 ± 0.025 for the lung in the FB and DIBH respiratory phase, respectively. For a similar target coverage (p > 0.05) in the DIBH respiratory phase between the AXB and AAA algorithm, there was a slight increase in organ at risk (OAR) dose for AXB in comparison to AAA, except for mean dose to the ipsilateral lung. AAA predicts higher mean dose to the ipsilateral lung and lesser V20Gy for the ipsilateral and common lung in comparison to AXB. The differences in mean dose to the ipsilateral lung were 0.87 ± 2.66 % (p > 0.05) in FB, and 1.01 ± 1.07% (p < 0.05) in DIBH, in V20Gy the differences were 1.76 ± 0.83% and 1.71 ± 0.82% in FB (p < 0.05), 3.34 ± 1.15 % and 3.24 ± 1.17 % in DIBH (p < 0.05), for the ipsilateral and common lung, respectively.ConclusionFor a similar target volume coverage, there were important differences between the AXB and AAA algorithm for low-density inhomogeneity medium present in the DIBH respiratory phase for left sided breast cancer patients. DIBH treatment in conjunction with AXB may result in better estimation of lung toxicities and treatment outcome.  相似文献   

11.
Acute respiratory distress syndrome is characterized by alterations in the ventilation-perfusion ratio. Present techniques for studying regional pulmonary perfusion are difficult to apply in the critically ill. Electron-beam computed tomography was used to study the effects of prone positioning on regional pulmonary perfusion in six healthy subjects. Contrast-enhanced sections were obtained sequentially in the supine, prone, and (original) supine positions at full inspiration. Regions of interest were placed along the nondependent to dependent axis and relative perfusion calculated. When corrected for the redistribution of lung parenchyma, a gravitational gradient of pulmonary perfusion existed in both supine and prone positions. The distribution of perfusion between the supine or prone positions did not differ, but data analysis using smaller regions of interest demonstrated marked heterogeneity of perfusion between anatomically adjacent regions of lung. The distribution of lung parenchyma was more uniform in the prone position. Gravity was estimated to be responsible for 22-34% of perfusion heterogeneity in the supine and 27-41% in the prone positions. These data support the hypothesis that factors other than gravity may be at least as important in determining the distribution of pulmonary perfusion in humans. The influence of nongravitational factors may not be detectable if techniques that sample large tissue volumes are employed.  相似文献   

12.
13.
PurposeA novel variable cycle-based respiratory guidance method was proposed to synchronize the patterns between patients’ breathing and the magnetic excitation of synchrotron under the mode of full-energy depth scanning beam delivery, in order to improve the treatment precision and efficiency for carbon ion therapy.MethodsAudio-visual biofeedback system with variable cycle-based respiratory guidance method was developed. We enrolled 6 healthy volunteers and a simulation study of the fixed cycle-based and variable cycle-based respiratory guidance with three treatment fractions was performed. A total of 72 breathing curves were collected for 4D dose calculations with three 4DCT datasets of lung tumor cases. Target dose coverage (D95: the percent dose covering 95% of the target), dose homogeneity (D5-D95), and treatment time were analyzed. The Wilcoxon signed-rank test was used for statistical difference analysis, and p < 0.05 was considered significant.ResultsWith the variable cycle-based respiratory guidance method, the breath hold phase of breathing curve could be synchronized with the synchrotron flat-top phase over time. The dose homogeneity was improved by factors of 1.94–2.92 compared to the fixed cycle-based respiratory guidance maneuvers alone or in combination with gating technique. Moreover, the treatment efficiency increased by 11–23%, depending on the duty cycle settings of the gating window.ConclusionsThe proposed variable cycle-based respiratory guidance method could improve both the treatment efficiency and precision under the mode of the full-energy depth scanning beam delivery for synchrotron-based carbon ion therapy.  相似文献   

14.
PurposeTo investigate the clinical significance of introducing model based dose calculation algorithms (MBDCAs) as an alternative to TG-43 in 192Ir interstitial breast brachytherapy.Materials and methodsA 57 patient cohort was used in a retrospective comparison between TG-43 based dosimetry data exported from a treatment planning system and Monte Carlo (MC) dosimetry performed using MCNP v. 6.1 with plan and anatomy information in DICOM-RT format. Comparison was performed for the target, ipsilateral lung, heart, skin, breast and ribs, using dose distributions, dose-volume histograms (DVH) and plan quality indices clinically used for plan evaluation, as well as radiobiological parameters.ResultsTG-43 overestimation of target DVH parameters is statistically significant but small (less than 2% for the target coverage indices and 4% for homogeneity indices, on average). Significant dose differences (>5%) were observed close to the skin and at relatively large distances from the implant leading to a TG-43 dose overestimation for the organs at risk. These differences correspond to low dose regions (<50% of the prescribed dose), being less than 2% of the prescribed dose. Detected dosimetric differences did not induce clinically significant differences in calculated tumor control probabilities (mean absolute difference <0.2%) and normal tissue complication probabilities.ConclusionWhile TG-43 shows a statistically significant overestimation of most indices used for plan evaluation, differences are small and therefore not clinically significant. Improved MBDCA dosimetry could be important for re-irradiation, technique inter-comparison and/or the assessment of secondary cancer induction risk, where accurate dosimetry in the whole patient anatomy is of the essence.  相似文献   

15.
PurposeA novel position-sensitive mega-size polycarbonate (MSPC) dosimeter is introduced. It provides photoneutron (PN) dose equivalent matrix of positions in and out of a beam of a high energy X-ray medical accelerator under a single exposure.MethodsA novel position-sensitive MSPC dosimeter was developed and applied. It has an effective etched area of 50 × 50 cm2, as used in this study, processed in a mega-size electrochemical etching chamber to amplify PN-induced-recoil tracks to a point viewed by the unaided eyes. Using such dosimeters, PN dose equivalents, dose equivalent profiles and isodose equivalent distribution of positions in and out of beams for different X-ray doses and field sizes were determined in a Siemens ONCOR Linac.ResultsThe PN dose equivalent at each position versus X-ray dose was linear up to 20 Gy studied. As the field size increased, the PN dose equivalent in the beam was also increased but it remained constant at positions out of the beam up to 20 cm away from the beam edge. The jaws and MLCs due to material differences and locations relative to the target produce different PN contributions.ConclusionsThe MSPC dosimeter introduced in this study is a perfect candidate for PN dosimetry with unique characteristics such as simplicity, efficiency, dose equivalent response, large size, flexibility to be bent, resembling the patient’s skin, highly position-sensitive with high spatial resolution, highly insensitive to X-rays, continuity in measurements and need to a single dosimeter to obtain PN dose equivalent matrix data under a single X-ray exposure.  相似文献   

16.
PurposeTo evaluate the impact of thermoplastic mask immobilization in the setup reproducibility and delivered dose for Helical Tomotherapy (HT) of the breast/chest wall.Methods16 patients treated with Accuray Hi-Art HT for breast-cancer were considered. Patients were positioned supine with arms extended above the head using Civco Wing Board (WB) system. In 50% of patients an Orfit thermoplastic mask was added in order to improve immobilization.Before each treatment fraction a megavoltage CT (MVCT) scan was taken and registered to the planning CT by experienced medical staff. The impact of thermoplastic mask was investigated analysing MVCT shift-roll data and MVCT dose distribution using Planned Adaptive software.ResultsIn the analysed cases, the addition of thermoplastic mask had minor impact on the lateral, longitudinal and roll data distribution. Variance of vertical shifts was significantly reduced in the WB + Orfit group. Van Herk's margins were not affected by addition of thermoplastic immobilization.In both groups, target coverage (V95) and maximum dose (D1) were almost identical to planned values. D1 of organs at risk were not significantly different in the two groups.ConclusionsAnalysis of shift-roll data shows no improvement in the group of patients immobilized with the addition of thermoplastic mask. Van Herk's margin is quite large (7–10 mm) in both groups evidencing the need to perform daily setup correction. The adapted dose distribution complies well with the planned one, showing that if MVCT is used before each treatment fraction, a 3 mm margin (setup component) for CTVs expansion could be adequate.  相似文献   

17.
PurposeTo evaluate the respiratory motion influence on the tridimensional (3D) dose delivery to breast-shaped phantoms using conformal radiotherapy (3D-RT), Field-in Field (FiF), and IMRT planning techniques.MethodsThis study used breast-shaped phantoms filled with MAGIC-f gel dosimeter to simulate the breast, and an oscillation platform to simulate the respiratory motion. The platform allowed motion in the anterior-posterior direction with oscillation amplitudes of 0.34 cm, 0.88 cm, and 1.22 cm. CT images of the static phantom were used for the 3D-RT, FiF, and IMRT treatment planning. Five phantoms were prepared and irradiated for each planning technique evaluated. Phantom 1 was irradiated static, phantoms 2–4 were irradiated moving with the three different motion amplitudes, and phantom 5 was used as a reference. The 3D dose distributions were obtained by relaxometry of magnetic resonance imaging, and the respiratory motion influence in the doses distribution was accessed by gamma evaluations (3%/3mm/15% threshold) comparing the measurements of the phantoms irradiated under movement with the static ones.ResultsThe mean gamma approvals for three oscillatory amplitudes were 96.44%, 93.23%, and 91.65%; 98.42%, 95.66%, and 94.31%; and 94.49%, 93.51%, and 86.62% respectively for 3D-RT, FiF and IMRT treatments. A gamma results profile per slice along the phantom showed that for FiF and IMRT irradiations, most of the failures occurred in the central region of the phantom.ConclusionsBy increasing the respiratory motion movement, the dose distribution variations for the three planning techniques were more pronounced, being the FiF technique variations the smallest one.  相似文献   

18.
PurposeTo perform a comprehensive dosimetric and clinical evaluation of the new Pinnacle Personalized automated planning system for complex head-and-neck treatments.MethodsFifteen consecutive head-neck patients were enrolled. Radiotherapy was prescribed using VMAT with simultaneous integrated boost strategy. Personalized planning integrates the Feasibility engine able to supply an “a priori” DVH prediction of the achievability of planning goals. Comparison between clinically accepted manually-generated (MP) and automated (AP) plans was performed using dose-volume histograms and a blinded clinical evaluation by two radiation oncologists. Planning time between MP and AP was compared. Dose accuracy was validated using the PTW Octavius-4D phantom together with the 1500 2D-array.ResultsFor similar targets coverage, AP plans reported less irradiation of healthy tissue, with significant dose reduction for spinal cord, brainstem and parotids. On average, the mean dose to parotids and maximal doses to spinal cord and brainstem were reduced by 13–15% (p < 0.001), 9% (p < 0.001) and 16% (p < 0.001), respectively. The integral dose was reduced by 16% (p < 0.001). The dose conformity for the three PTVs was significantly higher with AP plans (p < 0.001). The two oncologists chose AP plans in more than 80% of cases. Overall planning times were reduced to <30 min for automated optimization. All AP plans passed the 3%/2 mm γ-analysis by more than 95%.ConclusionComplex head-neck plans created using Personalized automated engine provided an overall increase of plan quality, in terms of dose conformity and sparing of normal tissues. The Feasibility module allowed OARs dose sparing well beyond the clinical objectives.  相似文献   

19.
PurposeThis study aims to investigate the use of machine learning models for delivery error prediction in proton pencil beam scanning (PBS) delivery.MethodsA dataset of planned and delivered PBS spot parameters was generated from a set of 20 prostate patient treatments. Planned spot parameters (spot position, MU and energy) were extracted from the treatment planning system (TPS) for each beam. Delivered spot parameters were extracted from irradiation log-files for each beam delivery following treatment. The dataset was used as a training dataset for three machine learning models which were trained to predict delivered spot parameters based on planned parameters. K-fold cross validation was employed for hyper-parameter tuning and model selection where the mean absolute error (MAE) was used as the model evaluation metric. The model with lowest MAE was then selected to generate a predicted dose distribution for a test prostate patient within a commercial TPS.ResultsAnalysis of the spot position delivery error between planned and delivered values resulted in standard deviations of 0.39 mm and 0.44 mm for x and y spot positions respectively. Prediction error standard deviation values of spot positions using the selected model were 0.22 mm and 0.11 mm for x and y spot positions respectively. Finally, a three-way comparison of dose distributions and DVH values for select OARs indicates that the random-forest-predicted dose distribution within the test prostate patient was in closer agreement to the delivered dose distribution than the planned distribution.ConclusionsPBS delivery error can be accurately predicted using machine learning techniques.  相似文献   

20.
BackgroundThe prevalence of nonalcoholic fatty liver disease (NAFLD) in Saudi Arabia is predicted to exceed 30% by 2030. NAFLD leads to liver fibrosis, thus increasing morbidity and health care burden. Obesity and diabetes have been strongly associated with NAFLD in different cities in Saudi Arabia.ObjectivesTherefore, we aim to determine the prevalence rate of NAFLD and specific risk factors for NAFLD among patients of tertiary care hospital of Taif city.Material and methodsWe retrospectively analyzed the medical records of patients for two years, between Feb 2017 and Feb 2019, (n = 100) referred to the hepatology clinic at King Abdulaziz Specialist Hospital in Taif. The diagnosis of NAFLD was based on the radiology report for patients who were aged >20 years old. Other parameters including fasting blood glucose (FBG), platelets count, alanine transaminase (ALT), aspartate transaminase (AST) and total bilirubin were statistically analyzed.ResultsWe found that 40% (P < 0.05) of all patients had NAFLD. The results revealed that a significantly high number of patients with NAFLD have high FBG levels (75%, P < 0.0001) and total bilirubin (P < 0.05). Meanwhile, platelet count was significantly reduced in patients with NAFLD (P < 0.05).ConclusionNAFLD can be a serious health problem in the Taif region. In addition, high FBG is a significant specific risk factor for NAFLD. Health care providers should pay more attention to limiting the prevalence of NAFLD and its risk factors.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号