首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Although bioacoustics is increasingly used to study species and environments for their monitoring and conservation, detecting calls produced by species of interest is prohibitively time consuming when done manually. Here we compared four methods for detecting and identifying roar-barks of maned wolves (Chrysocyon brachyurus) within long sound recordings: (1) a manual method, (2) an automated detector method using Raven Pro 1.4, (3) an automated detector method using XBAT and (4) a mixed method using XBAT's detector followed by manual verification. Recordings were done using a song meter installed at the Serra da Canastra National Park (Minas Gerais, Brazil). For each method we evaluated the following variables in a 24-h recording: (1) total time required analysing files, (2) number of false positives identified and (3) number of true positives identified compared to total number of target sounds. Automated methods required less time to analyse the recordings (77–93 min) when compared to manual method (189 min), but consistently presented more false positives and were less efficient in identifying true positives (manual = 91.89%, Raven = 32.43% and XBAT = 84.86%). Adding a manual verification after XBAT detection dramatically increased efficiency in identifying target sounds (XBAT+manual = 100% true positives). Manual verification of XBAT detections seems to be the best way out of the proposed methods to collect target sound data for studies where large amounts of audio data need to be analysed in a reasonable time (111 min, 58.73% of the time required to find calls manually).  相似文献   

2.
Implementation of the on-chip immunoassay for α-fetoprotein (AFP)-L3% was achieved using a fully automated microfluidic instrument platform that will prepare the chip and run the assay with a total assay time of less than 10 min. Reagent/sample mixing, concentration, and reaction in microfluidic channels occur by the electrokinetic analyte transport assay (EATA) technique, enabling the integration of all assay steps on-chip. The determination of AFP-L3%, a biomarker for hepatocellular carcinoma, was achieved by the presence of Lens culinaris agglutinin in the separation channel, causing separation of the fucosylated isoform, AFP-L3, from the nonfucosylated AFP-L1 by lectin affinity electrophoresis. Laser-induced-fluorescence (LIF) detection was used to quantitate the labeled immunocomplexes. The limit of detection (LOD) was 0.1 ng/ml AFP, and assay precision of less than 2% coefficient of variation (CV) was obtained for quantitation from 24 to 922 ng/ml total AFP in spiked serum samples. Assay precision of less than 3% CV was obtained for AFP-L3% measurements from 8.5 to 81%. Furthermore, good correlation of test results for 68 patient serum samples with a commercially available reference method (LiBASys assay for AFP-L3%) was obtained, with r= 0.981 and slope = 1.03.  相似文献   

3.
ABSTRACT Point counts are the most frequently used technique for sampling bird populations and communities, but have well‐known limitations such as inter‐ and intraobserver errors and limited availability of expert field observers. The use of acoustic recordings to survey birds offers solutions to these limitations. We designed a Soundscape Recording System (SRS) that combines a four‐channel, discrete microphone system with a quadraphonic playback system for surveying bird communities. We compared the effectiveness of SRS and point counts for estimating species abundance, richness, and composition of riparian breeding birds in California by comparing data collected simultaneously using both methods. We used the temporal‐removal method to estimate individual bird detection probabilities and species abundances using the program MARK. Akaike's Information Criterion provided strong evidence that detection probabilities differed between the two survey methods and among the 10 most common species. The probability of detecting birds was higher when listening to SRS recordings in the laboratory than during the field survey. Additionally, SRS data demonstrated a better fit to the temporal‐removal model assumptions and yielded more reliable estimates of detection probability and abundance than point‐count data. Our results demonstrate how the perceptual constraints of observers can affect temporal detection patterns during point counts and thus influence abundance estimates derived from time‐of‐detection approaches. We used a closed‐population capture–recapture approach to calculate jackknife estimates of species richness and average species detection probabilities for SRS and point counts using the program CAPTURE. SRS and point counts had similar species richness and detection probabilities. However, the methods differed in the composition of species detected based on Jaccard's similarity index. Most individuals (83%) detected during point counts vocalized at least once during the survey period and were available for detection using a purely acoustic technique, such as SRS. SRS provides an effective method for surveying bird communities, particularly when most species are detected by sound. SRS can eliminate or minimize observer biases, produce permanent records of surveys, and resolve problems associated with the limited availability of expert field observers.  相似文献   

4.
The formerly endangered Kirtland's warbler (Setophaga kirtlandii) is among a growing number of conservation-reliant species that depend on active management to avoid reverting to endangered status. Because the Kirtland's warbler is a habitat specialist of young, even-aged jack pine (Pinus banksiana), managers of the recovery effort stressed creating new jack pine stands and monitoring numbers of singing males through an annual census using single visits to individual stands. Kirtland's warbler will occupy and breed in red pine (P. resinosa), but red pine has not been surveyed for Kirtland's warblers in the annual population census. Furthermore, the current monitoring approach cannot determine their species detection probability or individual detection probability, which is essential to evaluate both red pine use and the accuracy of the census. From 2016–2018 we estimated density and detection probabilities in jack pine and red pine stands through repeated visits to a limited number of stands rather than single visits to many stands. Estimates of species detection probability indicated that ≥1 male Kirtland's warbler would be detected on most sites when any were present, but individual detection probabilities were less and varied by stand type, indicating that single visits to sites would underestimate numbers and that accurate estimation of detection probability was important for estimation of density in different stand types. We offer quantitative estimates of detection probabilities for determination of Kirtland's warbler population size in jack pine versus red pine stands in the same areas and breeding seasons. Managers of Kirtland's warblers should incorporate detection probabilities into population surveys to achieve more accurate estimates of population size.  相似文献   

5.
'Reverse-phase' protein lysate microarray (RPA) assays use micro-scale, cell lysate dot blots that are printed to a substrate, followed by quantitative immunochemical protein detection, known to be particularly effective across many samples. Large-scale sample collection is a labor-intensive and time-consuming process; the information yielded from RPA assays, however, provides unique opportunities to experimentally interpret theoretical protein networks quantitatively. When specific antibodies are used, RPA can generate 1,000 times more data points using 10,000 times less sample volume than an ordinary western blot, enabling researchers to monitor quantitative proteomic responses for various time-scale and input-dose gradients simultaneously. Hence, the RPA system can be an excellent method for experimental validation of theoretical protein network models. Besides the initial screening of primary antibodies, collection of several hundreds of sample lysates from 1- to 8-h periods can be completed in approximately 10 d; subsequent RPA printing and signal detection steps require an additional 2-3 d.  相似文献   

6.
We have developed a sensitive and inexpensive opto-fluidic ring resonator (OFRR) biosensor using phage as a receptor for analyte detection. Phages have distinct advantages over antibodies as biosensor receptors. First, affinity selection from large libraries of random peptides displayed on phage provides a generic method of discovering receptors for detecting a wide range of analytes with high specificity and sensitivity. Second, phage production can be less complicated and less expensive than antibody production. Third, phages withstand harsh environments, reducing the environmental limitations and enabling regeneration of the biosensor surface. In this work, filamentous phage R5C2, displaying peptides that bind streptavidin specifically, was employed as a model receptor to demonstrate the feasibility of a phage-based OFRR biosensor. The experimental detection limit was approximately 100pM streptavidin and the K(d(apparent)) is 25pM. Specificity was verified using the RAP 5 phage, which is not specific to streptavidin, as the negative control. Sensing surface regeneration results show that the phage maintained functionality after surface regeneration, which greatly improves the sensors' reusability. The phage-based OFRR biosensor will become a promising platform for universal biomolecule detection with high sensitivity, low cost, and good reusability.  相似文献   

7.
Allan Guan  Yi Wang 《Biofouling》2013,29(8):925-934
Abstract

Biological contamination of surfaces in industry and healthcare is an important vector of disease transmission. Current assays for detecting surface-adherent contamination require extraction of biological soil. However, physical inaccessibility or poor solubility may limit recovery. Here, how the o-phthalaldehyde (OPA) protein assay can be modified to measure residual protein (modeled with bovine serum albumin) or biofilm on a surface without extraction is described. The assay limit of detection (LOD) for protein was 1.6 µg cm?2. The detection threshold for Staphylococcus epidermis biofilm was 117 µg cm?2. The clinical utility of the method was demonstrated for measurements taken from clinically used endoscopes. Since this method is more sensitive than extraction-based testing, clinical results should not be compared with conventional benchmarks. By enabling direct detection and quantification of soils in complex or hard-to-reach areas, this method has potential to improve the margin of safety in medical and industrial cleaning processes.  相似文献   

8.
Aims: This study evaluates dialysis filtration and a range of PCR detection methods for identification and quantification of human adenoviruses in a range of environmental waters. Methods and Results: Adenovirus was concentrated from large volumes (50–200 l) of environmental and potable water by hollow fibre microfiltration using commercial dialysis filters. By this method, an acceptable recovery of a seeded control bacteriophage MS2 from seawater (median 95·5%, range 36–98%, n = 5), stream water (median 84·7%, range 23–94%, n = 5) and storm water (median 59·5%, range 6·3–112%, n = 5) was achieved. Adenovirus detection using integrated cell culture PCR (ICC‐PCR), direct PCR, nested PCR, real‐time quantitative PCR (qPCR) and adenovirus group F‐specific direct PCR was tested with PCR products sequenced for confirmation. Adenovirus was routinely detected from all water types by most methods, with ICC‐PCR more sensitive than direct‐nested PCR or qPCR. Group F adenovirus dominated in wastewater samples but was detected very infrequently in environmental waters. Conclusions and Implications: Human adenoviruses (HAdv) proved relatively common in environmental and potable waters when assessed using an efficient concentration method and sensitive detection method. ICC‐PCR proved most sensitive, could be used semiquantitatively and demonstrated virus infectivity but was time consuming and expensive. qPCR provided quantitative results but was c. ten‐fold less sensitive than the best methods.  相似文献   

9.
ABSTRACT.   Although offering many benefits over manual recording and survey techniques for avian field studies, automated sound recording systems produce large datasets that must be carefully examined to locate sounds of interest. We compared two methods for locating target sounds in continuous sound recordings: (1) a manual method using computer software to provide a visual representation of the recording as a sound spectrogram and (2) an automated method using sound analysis software preprogrammed to identify specific target sounds. For both methods, we examined the time required to process a 24-h recording, scanning accuracy, and scanning comprehensiveness using four different target sounds of Pileated Woodpeckers ( Dryocopus pileatus ), Pale-billed Woodpeckers ( Campephilus guatemalensis ), and putative Ivory-billed Woodpeckers ( Campehilus principalis ). We collected recordings from the bottomland forests of Florida and the Neotropical dry forests of Costa Rica, and compared manual versus automated cross-correlation scanning techniques. The automated scanning method required less time to process sound recordings, but made more false positive identifications and was less comprehensive than the manual method, identifying significantly fewer target sounds. Although the automated scanning method offers a fast and economic alternative to traditional manual efforts, our results indicate that manual scanning is best for studies requiring an accurate account of temporal patterns in call frequency and for those involving birds with low vocalization rates.  相似文献   

10.
Millions of Americans contract food poisoning or are affected by microbial pathogens each year. Rapid, sensitive detection of dilute levels of pathogens in foods, produce, water, and biomanufacturing process samples is key to consumer protection; however, current enrichment methods require as much as a full day to enrich viable bacterial pathogens to detectable levels. Our lab previously demonstrated the ability to concentrate and detect dilute levels of pathogens, within 8 hr, from various food matrices using microfiltration in our continuous cell concentration device (i.e., C3D) with one or two filter modules. This short communication describes the design, materials and construction, layout, and operational characteristics of a four filter module multiplexed system based on a four channel device. Benefits are a 2× greater sample capacity than an equivalent duplex system (achieving the same time to result of less than 8 hr from sample preparation to detection), simpler operation, and a footprint enabling operation inside a biosafety cabinet instead of requiring a BSL-2 room. Flow rate variability through four channels fit within an operational envelope of ±3%; flow rates are reproducible from one run to the next thus ensuring relatively simple, concurrent processing of samples.  相似文献   

11.
Controlling the course of the Coronavirus Disease 2019 (COVID-19) pandemic will require widespread deployment of consistent and accurate diagnostic testing of the novel Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2). Ideally, tests should detect a minimum viral load, be minimally invasive, and provide a rapid and simple readout. Current Food and Drug Administration (FDA)-approved RT-qPCR–based standard diagnostic approaches require invasive nasopharyngeal swabs and involve laboratory-based analyses that can delay results. Recently, a loop-mediated isothermal nucleic acid amplification (LAMP) test that utilizes colorimetric readout received FDA approval. This approach utilizes a pH indicator dye to detect drop in pH from nucleotide hydrolysis during nucleic acid amplification. This method has only been approved for use with RNA extracted from clinical specimens collected via nasopharyngeal swabs. In this study, we developed a quantitative LAMP-based strategy to detect SARS-CoV-2 RNA in saliva. Our detection system distinguished positive from negative sample types using a handheld instrument that monitors optical changes throughout the LAMP reaction. We used this system in a streamlined LAMP testing protocol that could be completed in less than 2 h to directly detect inactivated SARS-CoV-2 in minimally processed saliva that bypassed RNA extraction, with a limit of detection (LOD) of 50 genomes/reaction. The quantitative method correctly detected virus in 100% of contrived clinical samples spiked with inactivated SARS-CoV-2 at either 1× (50 genomes/reaction) or 2× (100 genomes/reaction) of the LOD. Importantly, the quantitative method was based on dynamic optical changes during the reaction and was able to correctly classify samples that were misclassified by endpoint observation of color.  相似文献   

12.
Glyphosate, the most used herbicide in the world, has a residue problem that cannot be ignored. However, glyphosate itself does not have fluorescence emission and lacks the conditions for fluorescence detection. In this work, a rapid and selective fluorescence detection method of glyphosate was designed by an ‘on–off–on’ fluorescent switch based on a luminous covalent organic framework (L-COF). Only the fixed concentration of Fe3+ as an intermediate could trigger the fluorescent switch and no incubation step was required. The proposed method showed good accuracy with a correlation coefficient of 0.9978. The method's limits of detection and quantitation were 0.88 and 2.93 μmol/L, which were lower than the maximum allowable residue limits in some regulations. Environmental water samples and tomatoes were selected as actual samples to verify the application in a complex matrix. A satisfactory mean recovery from 87% to 106% was gained. Furthermore, Fe3+ could induce fluorescence quenching of L-COF through the photo-induced electron transfer (PET) effect, while the addition of glyphosate could block the PET effect to achieve detection. These results demonstrated the proposed method had abilities to detect glyphosate and broaden the application of L-COF.  相似文献   

13.
The aim of this study was to develop a methodology to rapidly detect viable Mycobacterium avium subsp. paratuberculosis (MAP) in clinical blood samples. MAP cells spiked into commercially available blood were recovered using optimised peptide-mediated magnetic separation (PMMS) and detected using a phage-based method, and the identity of the cells detected confirmed using nested-PCR amplification of MAP signature sequences (IS900). The limit of detection was determined to be 10 MAP cells per ml of blood and was used to detect MAP present in clinical bovine blood samples. Using the PMMS-phage method there was no difference when detecting MAP from whole blood or from isolated buffy coat. MAP was detected in animals that were milk-ELISA positive (15 animals) by PMMS-phage and no MAP was detected in blood samples from an accredited Johne's disease free herd (5 animals). In a set of samples from one herd (10 animals) that came from animals with variable milk ELISA status, the PMMS-phage results agreed with the positive milk-ELISA results in all but one case. These results show that the PMMS-phage method can detect MAP present in naturally infected blood. Total assay time is 48 h and, unlike PCR-based detection tests, only viable cells are detected. A rapid method for detecting MAP in blood could further the understanding of disseminated infection in animals with Johne's disease.  相似文献   

14.
A generic method for the detection of covalent adducts to the cysteine-34 residue of human serum albumin (HSA) has been developed, based on an on-line combination of immunoaffinity chromatography for selective sample pre-treatment, solution phase digestion, liquid chromatography and tandem mass spectrometry. Selective anti-HSA antibodies immobilized on agarose were used for sample pre-concentration and purification of albumin from the chemically produced alkylated HSA. After elution, HSA and HSA adducts are mixed with pronase and directed to a reaction capillary kept at a digestion temperature of 70 degrees C. The digestion products were trapped on-line on a C18 SPE cartridge. The peptides were separated on a reversed-phase column using a gradient of organic modifier and subsequently detected using tandem mass spectrometry. Modified albumin samples consisted of synthetically alkylated HSA by the reactive metabolite of acetaminophen, N-acetyl-p-benzoquinoneimine (NAPQI), and using the alkylating agent 1-chloro-2,4-dinitrobenzene (CDNB) as reference. The resulting mixture of alkylated versus non-modified albumin has been applied to the on-line system, and alkylation of HSA is revealed by the detection of the modified marker tetra-peptide glutamine-cysteine-proline-phenylalanine (QCPF) adducts NAPQI-QCPF and CDNB-QCPF. Detection of alkylated species was enabled by the use of data comparison algorithms to distinguish between unmodified and modified HSA samples. The in-solution digestion proved to be a useful tool for enabling fast (less than 2 min) and reproducible on-line digestion of HSA. A detection limit of 1.5 micromol/L of modified HSA could be obtained by applying 10 microL of NAPQI-HSA sample.  相似文献   

15.
This article reports a simple electrochemical approach for the detection of multiple proteins (thrombin and lysozyme) using Dabcyl-labeled aptamer modified metal nanoparticles (DLAPs). DLAPs were immobilized on β-cyclodextrins (β-CDs) modified electrode by means of host–guest self-assembly. During the time of detection, the aptamers' structure will change due to the specific binding with corresponding proteins that forced DLAPs far away from the electrode that had been modified by β-CDs. Thus, the capture of target proteins onto DLAPs was translated via the electrochemical current signal offered by metal nanoparticles. Linearity of the aptasensor for quantitative measurements was demonstrated. Determinations of proteins in human real serum samples were also performed to demonstrate detection in real clinical samples.  相似文献   

16.
Rhodamine B (RB) is a popular bait-marking tool in wildlife research, although its use has required many assumptions about marking reliability. These assumptions have limited dosage ranges and detection methods in research applications. Identification of alternate detection methods, hair types, and dosage rates could create new opportunities for RB use and potentially reduce adverse effects on target animals. We examined the relationship between hair types, dosage rate, and detection method for RB applications using black rats (Rattus rattus) in laboratory settings. We gave study animals varying doses of RB, and examined vibrissae and guard hairs for the detection of RB bands using ambient light, ultraviolet (UV) light, and fluorescence microscopy techniques. Fluorescence microscopy detected more RB marked hairs than UV light or ambient light. Fluorescence microscopy was more sensitive to RB dose rate detection; with receiver operating characteristic curves suggesting that the minimum dose rates at which RB intake can be correctly detected are 3.9 and 33 mg/kg for vibrissae and guard hairs, respectively. Guard hair RB detection was less reliable under ambient light and UV lamps, but equally detectable as vibrissae under fluorescence microscopy. Our results confirmed the interrelationship between dosage and detection methods in the efficacy of bait markers. We demonstrated that guard hairs can be a reliable hair type for the detection of RB. This application is less invasive than sampling animal tissues to detect bait uptake. © 2012 The Wildlife Society.  相似文献   

17.
We compared the effectiveness and cost of distribution surveys using livetrapping to those using detection dog-handler teams for a cryptic rodent (Franklin's ground squirrel [Poliocitellus franklinii]). We livetrapped at 62 sites in Illinois, Indiana, Iowa, Missouri, and Wisconsin for Franklin's ground squirrels in 2007–2009 and surveyed 40 of those sites using detection dogs in 2009. Independent surveys of a site by 2 dog-handler teams took <1 hr and yielded detection rates comparable to 2 daily livetrapping surveys (detection rate = 83–84%). However, false presences are a potential problem when detection dogs are trained to scent of a species that leaves little visual sign to confirm its presence. Surveys by 2 dog-handler teams cost >2 daily livetrapping surveys conducted by 2 technicians but more and larger sites can be surveyed by dog-handler teams in a shorter time. For surveys covering large spatial scales or when time is a limiting factor, number of false presences, and study costs can be reduced by employing a 2-stage survey protocol in which livetrapping is conducted only at sites where detection dog surveys indicate presence. We conclude a 2-stage strategy could be used effectively in large-scale surveys for a variety of rare and cryptic species. © 2011 The Wildlife Society.  相似文献   

18.
Aims:  The aim of this study is to develop an RT-PCR assay combined with immunomagnetic beads (IMS/RT-PCR) coating monoclonal antibody (Mab) for separation and detection of norovirus (genogroup II) in faecal samples. We furthermore compare its detection limits with IMS/RT-PCR using polyclonal antibody (Pab) and the TRIzol extraction method followed by RT-PCR (TRIzol-RT-PCR).
Methods and Results:  Mab-coated beads and Pab-coated beads were added to a series of tenfold dilutions of faecal extract containing norovirus in 1 ml PBS. After incubation and collection, the RNA was released by heating from virus separated by beads. The tenfold dilutions of faecal were also extracted with TRIzol reagent. The RNA was used as the template for RT-PCR detection (primers: JV12–JV13). IMS/RT-PCR using Mab showed an endpoint in the 10−7 dilution and was 102 times more sensitive than IMS/RT-PCR using Pab and was at least 103 times more sensitive than TRIzol-RT-PCR method.
Conclusions:  IMS/RT-PCR using Mab proved to be a more sensitive method of noroviruses (NVs) detection than IMS/RT-PCR using Pab and the TRIzol-RT-PCR method.
Significance and Impact of the Study:  This is the first study to detect NVs with IMS/RT-PCR using Mab, and could serve as a model for future assays when broadly reactive NVs-specific Mabs are developed.  相似文献   

19.
In this article we report a new biosensor‐based method that is more sensitive and rapid than the current approach for detecting mycoplasma in cell culture samples. Piezoelectric‐excited millimeter‐sized cantilever (PEMC) sensors respond to mass change via resonant frequency change. They are sensitive at femtogram level and can be used directly in liquid for label‐free detection. Common cell culture contaminant, Acholeplasma laidlawii was detected in both buffer and cell culture medium. Two different sources (positive control from a commercial kit and ATCC 23206) were analyzed using antibody‐immobilized PEMC sensor. Resonant frequency decrease caused by binding of A. laidlawii was monitored in real‐time using an impedance analyzer. Positive detection was confirmed by a second antibody binding. The limit of detection (LOD) was lower than 103 CFU/mL in cell culture medium using PEMC sensor while parallel ELISA assays showed LOD as 107 CFU/mL. This study shows that PEMC sensor can be used for sensitive and rapid mycoplasma detection in cell culture samples. Biotechnol. Bioeng. 2010;105: 1069–1077. © 2009 Wiley Periodicals, Inc.  相似文献   

20.
【目的】探讨、优化基于环介导等温扩增技术(LAMP)快速检测常规食品中感染性痢疾志贺氏菌的方法。【方法】在NCBI数据库中搜索获取志贺氏菌的特异性基因高度保守区,设计3对LAMP反应引物,建立、优化该LAMP可视化检测方法,并评价其特异性、灵敏度,同时与PCR检测方法和传统检测方法对比,进行结果统计分析。【结果】5株志贺氏菌标准菌株样品均检测为阳性,11株非志贺氏菌标准菌株样品均检测为阴性,无交叉反应。最低检验限为1.6×101 CFU/反应(或1.6×101 CFU/m L),且经比较,LAMP检测灵敏度比PCR检测高出1个数量级。通过对161份实际样品和人工污染样品进行检测,LAMP检测与传统方法检测结果具有较高的一致性。【结论】LAMP具有检测过程快速简便、检测结果稳定、可靠的特点,适用于对常规食品中感染性痢疾志贺氏菌的高效、快速检测需求。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号