首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
A sensitive, selective and reproducible reversed-phase high-performance liquid chromatographic method is described for the quantification of sotalol in human serum and urine. Sotalol and the internal standard, atenolol, were extracted from alkalinized serum and urine (pH 9.0) into 1-butanol—chloroform (20:60, v/v). The organic phase was evaporated, and to the residue was added 0.1 M sulphuric acid (serum analysis) or mobile phase (urie analysis). The mobile phase consisted of 0.01 M phosphate buffer (pH 3.2) and acetonitrile (20:80, v/v) containing 3 mM n-octylsodium sulphate. The flow-rate was 1.5 ml/min. The retention times of atenolol and sotalol were 7 and 10 min, respectively. Ultraviolet detection at 226 nm made it possible to achieve a detection limit of 0.03 μmol/l.  相似文献   

3.
A selective and sensitive method for the determination of gentamicin in plasma and urine by high-performance liquid chromatography has been developed. Following deproteinization, the gentamicin is reacted with fluorescamine to produce a fluorescent derivative. This reaction mixture is directly chromatographed on a cation-exchange column using as mobile phase acetonitrile—phosphoric acid (7:3). The gentamicin components elute as a single peak. Using 0.1 ml of plasma, quantitation of gentamicin concentrations as low as 1 mg/l are possible. Possible interference from other aminoglycosides and antibiotics is discussed.  相似文献   

4.
A high-performance liquid chromatographic (HPLC) method with ultraviolet detection for the determination of quinine in rat biological fluids is described. Due to its selectivity and sensitivity, the proposed method can be used in the case of such rat biological fluids as cerebrospinal fluid (CSF) and perilymph for which the accessible volumes are limited to 100 μl and 10 μl, respectively. Consequently, the assay method has been applied to the measurements of quinine concentration in rat plasma, CSF and perilymph samples.  相似文献   

5.
Methocarbamol enantiomers in rat and human plasma were quantified using a stereospecific high-performance liquid chromatographic method. Racemic methocarbamol and internal standard, (R)-(−)-flecainide, were isolated from plasma by a single-step extraction with ethyl acetate. After derivatization with the enantiomerically pure reagent (S)-(+)-1-(1-naphthyl)ethyl isocyanate, methocarbamol diastereomers and the (R)-flecainide derivative were separated on a normal-phase silica column with a mobile phase consisting of hexane—isopropanol (95:5, v/v) at a flow-rate of 1.6 ml/min. Ultraviolet detection was carried out at a wavelength of 280 nm. The resolution factor between the diastereomers was 2.1 (α = 1.24). An excellent linearity was observed between the methocarbamol diastereomers/internal standard derivative peak-area ratios and plasma concentrations, and the intra- and inter-day coefficients of variation were always <9.8%. The lowest quantifiable concentration was 0.5 μg/ml for each enantiomer (coefficients of variation of 9.8 and 8.8% for (S)- and (R)-methocarbamol, respectively), while the limit of detection (signal-to-noise ratio 3:1) was approximately 10 ng/ml. The assay was used to study the pharmacokinetics of methocarbamol enantiomers in a rat following intravenous administration of a 120 mg/kg dose of racemic methocarbamol and to evaluate plasma and urine concentrations in a human volunteer after oral administration of a 1000-mg dose of the racemate. The method is suitable for stereoselective pharmacokinetic studies in humans as well as in animal models.  相似文献   

6.
A rapid and selective reversed-phase high-performance liquid chromatographic method for the simultaneous determination of hypoxanthine and xanthine in biological fluids was developed. The identification of hypoxanthine and xanthine was confirmed by xanthine oxidase reaction. This method was applied to the investigation of purine metabolism in subjects with xanthine oxidase deficiency or gout. Hypoxanthine concentrations three to ten times higher than those determined in plasma were found in erythrocyte samples from normal subjects and from patients with xanthine oxidase deficiency or hyperuricemia under allopurinol therapy.  相似文献   

7.
The four stereoisomers of the combined α- and β-adrenoceptor antagonist labetalol were separated and quantified at therapeutic concentrations by normal-phase high-pressure liquid chromatography using a chiral stationary phase and fluorescence detection. Drug in plasma or urine was recovered by solid-phase extraction with 83±5% efficiency. Limits of detection from biological samples (3 ml) were between 1.5–1.8 ng ml−1. Intra-day and inter-day variation at 25 ng ml−1 were ≤2.7% and ≤5.80% respectively for all stereoisomers. The assay was applied to an examination of the disposition of labetalol stereoisomers after a single oral dose of racemate to a human volunteer. Labetalol appears to undergo enantioselective metabolism leading to relatively low plasma concentrations of the pharmacologically active enantiomers.  相似文献   

8.
9.
A rapid, sensitive, and specific high-performance liquid chromatographic method is described for the quantitative analysis of sulfinpyrazone and its sulfone and p-hydroxy metabolites in plasma and urine. The method uses two different procedures for sample preparation: (1) a rapid and convenient procedure using a single extraction with 1-chlorobutane and subsequent back-extraction into sodium hydroxide solution for the analysis of sulfinpyrazone and its sulfone metabolite, and (2) a more time consuming procedure using triple extraction with ethylene dichloride, a buffer wash, and back extraction into the base for the additional analysis of the p-hydroxy metabolite. The lower limit of sensitivity for sulfinpyrazone is 50 ng/ml. Concentrations of sulfinpyrazone between 0.05 to 0.1 and 50 μg/ml were measured with an average coefficient of variation of 3.9%, ranging from 1.5 to 6.1%.  相似文献   

10.
11.
A selective and sensitive reversed-phase liquid chromatographic method for the analysis of thiopurine bases, nucleosides and nucleotides in biological samples was developed. A simple and rapid sample treatment procedure using perchloric acid deproteinization with dithiothreitol for the analysis of thiopurine bases and nucleosides is presented. The addition of dithiothreitol during sample collection and treatment improves recoveries. This procedure also allows the determination of thiopurine nucleotides by hydrolysis to their free bases after heating of the perchloric acid extract. The method was applied to the analysis of thiopurine metabolites in plasma and erythrocytes from lung-transplant patients under azathioprine therapy.  相似文献   

12.
A high-performance liquid chromatographic method has been developed for the analysis of the novel antiparasitic agent, licochalcone A (Lica), and three of its glucuronic acid conjugates in plasma and urine. The high-performance liquid chromatography assay was performed using gradient elution and UV detection at 360 nm. The proposed technique is selective, reliable and sensitive. The limits of quantification for Lica are 0.2 μg/ml in plasma and 0.14 μg/ml in urine, 1.2 μg/ml for the 4′-glucuronide in plasma and 1.4 μg/ml in urine, and 2.0 μg/ml for the 4-glucuronide in plasma and 3.2 μg/ml in urine. The reproducibility of the analytical method according to the statistical coefficients is 7% or below. The accuracy of the method is good, that is, the relative error is below 10%. The stability of Lica and its glucuronides in urine and plasma samples has been assessed during storage in the autosampler and freezer. The applicability of the assay for determining Lica and its intact glucuronide conjugates in biological fluids was shown using a single dose study in rat.  相似文献   

13.
The basic principle of derivatization of a hydrazide moiety with an aldehyde as applied in the method developed by Lacroix et al. [J. Chromatogr., 307 (1984) 137–144] for the quantitation of isoniazid and acetylisoniazid was imppoved by modification, standardization and extension to allow quantitation of hydrazine in patient samples. It could be shown that 40 μl of 1% methanonic cinnamaldehyde per 200 μl of deproteinized analysate gave maximal chromophoric isoniazid-cinnamaldehyde conjugate, read at 340 nm. The hydrolytic loss of isoniazid, crucial to the quantitation of acetylisoniazid, could be compensated for by introduction of an appropriate set of calibration curves. Although the method described here allows quantitation of monoacetylhydrazie and diacetylhydrazine, in addition to hydrazine, in mono-spiked samples, the method cannot be used for the quantitation of the acetylated metabolites of hydrazine in patient samples because of a lack of specificity. Linear calibration curves in the range 1–25 μg/ml for isoniazid and acetylisoniazid, 10–400 ng/ml for hydrazine and 50–1000 ng/ml for mono-acetylhydrazine and diacetylhydrazine, could be constructed; analyte recoveries approaching 100% could be achieved in all instances.  相似文献   

14.
1069C85 is a novel tubulin binder developed to circumvent the resistance associated with the Vinca alkaloids. Cytotoxic activity has been demonstrated in vitro against a variety of tumour cell lines, including a variant of the P388 leukaemia with acquired resistance to vincristine. A phase I clinical trial is planned and an assay suitable for preclinical and clinical pharmacokinetics has been developed. A high-performance liquid chromatographic (HPLC) assay is described which allows measurement of 1069C85 in plasma, urine, and tissue samples. The method uses reversed-phase chromatography with isocratic elution and detection by fluorescence at 406 nm following excitation at 340 nm. The assay is specific, sensitive (limit of sensitivity 0.25 ng/ml) and reproducible (coefficient of variation <5%). The method has been used to study the pharmacokinetics of 1069C85 in Balb C mice following a single oral dose of 1 mg/kg. The maximum plasma concentration was reached 15 min after administration and subsequent elimination was slow with a half life of 6.5 ± 2.2 h. The drug remained detectable in plasma, at 1 ± 0.5 ng/ml, 24 h after this dose. This assay will be used to determine the pharmacokinetic profile of 1069C85 in mice and in a forthcoming phase I clinical trial.  相似文献   

15.
A sensitive and selective high-performance liquid-chromatographic assay for ibuprofen and its major metabolites in biological fluids is described. To ensure good chromatographic separation the drug and metabolites were run on a gradient elution system and detected with a variable wavelength detector set at 220 nm. A second, more rapid, isocratic system is also described for the detection of only ibuprofen.  相似文献   

16.
High-performance liquid chromatographic assay for cefepime in serum   总被引:6,自引:0,他引:6  
A simple, rapid, specific and sensitive high-performance liquid chromatographic method was developed for the determination of cefepime 1-[[6R, 7R)-7-[2-(2-amino-4-thiazolyl)glyoxylamido]-2-carboxy-8-oxo-5-thia-1-azabicyclo-[4.2.0] oct-2-en-3-yl]methyl]-1-methylpyrrolidinium hydroxide, inner salt, 72-(Z)-(O-methyloxime) in human serum. Separation was achieved on a reversed-phase Ultrasphere XL-ODS column (75×4.6 mm I.D.). The mobile phase was 7% acetonitrile in 20 mM ammonium acetate (pH 4). Cefepime eluted in the range of 1.8–2.2 min. Detection was by UV absorbance at 254 nm. The lower limit of quantitation of cefepime in plasma was 0.5 μg/ml. The average absolute recovery was 106.2±2.1%. The linear range was from 0.1 to 50 μg/ml, with a correlation coefficient greater than 0.999. The within-day C.V.s for human samples were 4.9 and 2.3% for 1 and 50 μg/ml, respectively. The between-day C.V.s for human serum samples were 14.5, 7.4 and 6.7 for 1, 25 and 50 μg/ml, respectively. Cefepime was found to be unstable in serum at room temperature. For delayed assay, samples must be stored at −80°C.  相似文献   

17.
High-performance liquid chromatographic procedures have been developed for the measurement of meropenem in serum. The separation was performed on an Ultrasphere XL-ODS analytical column (75×4.6 mm I.D.). The mobile phase consisted of 10.53 mmol/l ammonium acetate-acetonitrile (95:5, v/v) (pH 4). The UV detection was at 298 nm. The quantitation limit both in serum and water was 0.25 μg/ml. The method was validated in serum and aqueous solution over the concentration range 0.25–50 μg/ml. The extraction recovery from serum spiked with meropenem was 99.7±3.4%. The intra- and inter-assay coefficients of variation were below 6%. Stored at −80°C for three months at various concentrations in serum and in aqueous solution, meropenem did not reveal any appreciable degradation. After 24 h, it was also stable at 4°C in serum, aqueous solution and supernatant of extraction but not at room temperature. The stability of the drug was also confirmed in serum after repeated freezing-thawing cycles at −80°C on four consecutive days.  相似文献   

18.
This paper describes a simple, rapid and reproducible high-performance liquid chromatographic method (HPLC) with ultraviolet absorbance detection for the analysis of melphalan in plasma. The HPLC column was an Ultrasphere ODS (5 μm) and the eluent was composed of methanol, purified water and acetic acid (49.5:49.5:1, v/v). The detection was performed at 261 nm. The method involved a simple treatment of the samples with methanol. The propylparaben was used as internnal standard. Linear detection response was obtained for concentrations ranging from 50 to 2500 ng/ml. Recovery from plasma proved to be more than 90%. Precision, expressed as C.V., was in the 0.5 to 9% range. Accuracy ranged from 95 to 102%. This method was used to determine the pharmacokinetic parameters of melphalan following high-dose (140 mg/m2) intravenous administration in patients with advanced malignancies undergoing peripheral blood hematopoietic progenitor-cell transplantation.  相似文献   

19.
A sensitive assay for pilocarpine in biological fluids has been developed involving HPLC of a fluorescent derivative of 4-bromomethyl-7-methoxycoumarin. Pilosine as internal standard was added before the derivatisation step. The fluorescent derivatives were well resolved and separated from excess reagent and endogeneous compounds on a cyanopropyl silica column. The detection limit of pilocarpine in biological fluids was 1.0 ng/ml and the assay was linear up to a concentration of 150 ng/ml. The assay was applied to a preliminary study of pilocarpine disposition in man after a single oral dose. This is the first report of pilocarpine excretion into saliva.  相似文献   

20.
A completely automated high-performance liquid chromatographic system is described for the determination of the phenolic anaesthetic propofol. The method is based on pre-column extraction in a closed system allowing direct injection of biological samples without any sample pretreatment. The assay is sensitive (limit of quantification is 5 ng/ml serum), reliable (the variability within a series is 2%) and rapid (results are available after 6 min).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号