首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Tennis stroke mechanics have attracted considerable biomechanical analysis, yet current filtering practice may lead to erroneous reporting of data near the impact of racket and ball. This research had three aims: (1) to identify the best method of estimating the displacement and velocity of the racket at impact during the tennis serve, (2) to demonstrate the effect of different methods on upper limb kinematics and kinetics and (3) to report the effect of increased noise on the most appropriate treatment method. The tennis serves of one tennis player, fit with upper limb and racket retro-reflective markers, were captured with a Vicon motion analysis system recording at 500 Hz. The raw racket tip marker displacement and velocity were used as criterion data to compare three different endpoint treatments and two different filters. The 2nd-order polynomial proved to be the least erroneous extrapolation technique and the quintic spline filter was the most appropriate filter. The previously performed "smoothing through impact" method, using a quintic spline filter, underestimated the racket velocity (9.1%) at the time of impact. The polynomial extrapolation method remained effective when noise was added to the marker trajectories.  相似文献   

2.
Biomechanical models are in use to estimate parameters such as contact forces and stability at various joints. In one class of these models, surface electromyography (EMG) is used to address the problem of mechanical indeterminacy such that individual muscle activation patterns are accounted for. Unfortunately, because of the stochastical properties of EMG signals, EMG based estimates of muscle force suffer from substantial estimation errors. Recent studies have shown that improvements in muscle force estimation can be achieved through adequate EMG processing, specifically whitening and high-pass (HP) filtering of the signals. The aim of this paper is to determine the effect of such processing on outcomes of a biomechanical model of the lumbosacral joint and surrounding musculature. Goodness of fit of estimated muscle moments to net moments and also estimated joint stability significantly increased with increasing cut-off frequencies in HP filtering, whereas no effect on joint contact forces was found. Whitening resulted in moment estimations comparable to those obtained from optimal HP filtering with cut-off frequencies over 250 Hz. Moreover, compared to HP filtering, whitening led to a further increase in estimated joint-stability. Based on theoretical models and on our experimental results, we hypothesize that the processing leads to an increase in pick-up area. This then would explain the improvements from a better balance between deep and superficial motor unit contributions to the signal.  相似文献   

3.
Motion capture systems currently used in biomechanical analysis introduce systematic measurement errors that appear in the form of noise in recorded displacement signals. The noise is unacceptably amplified when differentiating displacements to obtain velocities and accelerations. To avoid this phenomenon, it is necessary to smooth the displacement signal prior to differentiation in order to eliminate the noise introduced by the experimental system. The use of singular spectrum analysis (SSA) is presented in this paper as an alternative to traditional digital filtering methods. SSA is a novel non-parametric technique based on principles of multivariate statistics. The original time series is decomposed into a number of additive time series, each of which can be easily identified as being part of the modulated signal, or as being part of the random noise. Several examples that demonstrate the superiority of this technique over other methods used in biomechanical analysis are presented in this paper.  相似文献   

4.
 In many applications of signal processing, especially in communications and biomedicine, preprocessing is necessary to remove noise from data recorded by multiple sensors. Typically, each sensor or electrode measures the noisy mixture of original source signals. In this paper a noise reduction technique using independent component analysis (ICA) and subspace filtering is presented. In this approach we apply subspace filtering not to the observed raw data but to a demixed version of these data obtained by ICA. Finite impulse response filters are employed whose vectors are parameters estimated based on signal subspace extraction. ICA allows us to filter independent components. After the noise is removed we reconstruct the enhanced independent components to obtain clean original signals; i.e., we project the data to sensor level. Simulations as well as real application results for EEG-signal noise elimination are included to show the validity and effectiveness of the proposed approach. Received: 6 November 2000 / Accepted in revised form: 12 November 2001  相似文献   

5.
‘Endpoint error’ describes the erratic behavior at the beginning and end of the computed acceleration data which is commonly observed after smoothing and differentiating raw displacement data. To evaluate endpoint error produced by four popular smoothing and differentiating techniques, Lanshammar's (1982, J. Biomechanics 15, 99–105) modification of the Pezzack et al. (1977, J. Biomechanics, 10, 377–382) raw angular displacement data set was truncated at three different locations corresponding to the major peaks in the criterion acceleration curve. Also, for each data subset, three padding conditions were applied. Each data subset was smoothed and differentiated using the Butterworth digital filter, cubic spline, quintic spline, and Fourier series to obtain acceleration values. RMS residual errors were calculated between the computed and criterion accelerations in the endpoint regions. Although no method completely eliminated endpoint error, the results demonstrated clear superiority of the quintic spline over the other three methods in producing accurate acceleration values close to the endpoints of the modified Pezzack et al. (1977) data set. In fact, the quintic spline performed best with non-padded data (cumulative error=48.0 rad s−2). Conversely, when applied to non-padded data, the Butterworth digital filter produced wildly deviating values beginning more than the 10 points from the terminal data point (cumulative error=226.6 rad s−2). Each of the four methods performed better when applied to data subsets padded by linear extrapolation (average cumulative error=68.8 rad s−2) than when applied to analogous subsets padded by reflection (average cumulative error=86.1 rad s−2).  相似文献   

6.
Heart rate variability (HRV) is an important and useful index to assess the responses of the autonomic nervous system (ANS). HRV analysis is performed using electrocardiography (ECG) or photoplethysmography (PPG) signals which are typically subject to noise and trends. Therefore, the elimination of these undesired conditions is very important to achieve reliable ANS activation results. The purpose of this study was to analyze and compare the effects of preprocessing on the spectral analysis of HRV signals obtained from PPG waveform. Preprocessing consists of two stages: filtering and detrending. The performance of linear Butterworth filter is compared with nonlinear weighted Myriad filter. After filtering, two different approaches, one based on least squares fitting and another on smoothness priors, were used to remove trends from the HRV signal. The results of two filtering and detrending methods were compared for spectral analysis accomplished using periodogram, Welch's periodogram and Burg's method. The performance of these methods is presented graphically and the importance of preprocessing clarified by comparing the results. Although both filters have almost the same performance in the results, the smoothness prior detrending approach was found more successful in removing trends that usually appear in the low frequency bands of PPG signals. In conclusion, the results showed that trends in PPG signals are altered during spectral analysis and must be removed prior to HRV analysis.  相似文献   

7.
Inverse dynamics is a standard tool in biomechanics, which requires low-pass filtering of external force and kinematic signals. Unmatched filtering procedures are reported to affect joint moment amplitudes in high impact movements, like landing or cutting, but are also common in the analysis of distance running. We analyzed the effects of cut-off frequencies in 94 rearfoot runners at a speed of 3.5 m/s. Additionally, we investigated whether the evaluation of footwear interventions is affected by the choice of cut-off frequencies. We performed 3D inverse dynamics for the hip, knee and ankle joints using different low-pass filter cut-off frequency combinations for a recursive fourth-order Butterworth filter. We observed fluctuations of joint moment curves in the first half of stance, which were most pronounced for the most unmatched cut-off frequency combination (kinematics: 10 Hz; ground reaction forces (GRFs): 100 Hz) and for more proximal joints. Peak sagittal plane hip joint moments were altered by 94% on average. We observed a change in the ranking of subjects based on joint moment amplitude. We found significant (p < 0.001) footwear by cut-off frequency combination interaction effects for most peak joint moments. These findings highlight the importance of cut-off frequency choice in the analysis of joint moments and the assessment of footwear interventions in distance running. Based on our results, we propose to use matched cut-off frequencies around 20 Hz in order to avoid large artificial fluctuations in joint moment curves while at the same time avoiding a severe removal of physiological high-frequency signal content from the GRF signals.  相似文献   

8.
Adaptive filter model of the cerebellum   总被引:1,自引:0,他引:1  
The Marr-Albus model of the cerebellum has been reformulated with linear system analysis. This adaptive linear filter model of the cerebellum performs a filtering action of a phase lead-lag compensator with learning capability, and will give an account for the phenomena which have been termed cerebellar compensation. It is postulated that a Golgi cell may act as a phase lag element; for example, as a leaky integrator with time constant about several seconds. Under this assumption, a mossy fiber-granule cell-Golgi cell input network functions as a phase lead-lag compensator. Output signals from Golgi-granule cell systems, namely, parallel fiber signals, are gathered together through variable synaptic connections to form a Purkinje cell output. From a general theory of adaptive linear filters, learning principles for these modifiable connections are derived. By these learning principles, a Purkinje cell output converges to the desired response to minimize the mean square error of the performance. In a more general sense, a Purkinje cell acquires a filtering function on the basis of multiple pairs of input signals and corresponding desired output signals. The mode of convergence of the output signal is described when the input signal is sinusoidal.  相似文献   

9.
海拔梯度上青海云杉径向生长与气候关系稳定性研究   总被引:2,自引:0,他引:2  
以祁连山北坡海拔2 700m(分布下限)、3 000m(中部)和3 300m(分布上限)的青海云杉为研究对象,采用长短两种不同步长的样条函数去趋势对1952~1980年和1981~2009年两个时段青海云杉径向生长与气候的关系进行对比分析,以揭示青海云杉年轮中包含的不同频率生长趋势与气候之间的关系及其在海拔梯度上的差异,探讨海拔梯度上气候变化对树木径向生长的影响。结果显示:(1)随着海拔升高,限制青海云杉径向生长的气候因子从降水转变为温度,不同时期的限制因子也发生变化。(2)在海拔2 700m处,上一年12月份平均温度与青海云杉生长的关系发生了分异,小步长的样条函数得到的年表中保留了较多降水信号;海拔3 000m处青海云杉径向生长与上年9月份降水量、平均温度表现出显著正相关关系;海拔3 300m处青海云杉生长与当年夏季降水量呈显著正相关关系,而在后一时段相关关系不显著,与当年春季、夏季的平均温度相关关系不稳定,大步长的样条函数得到的年表中表现出温度与生长关系的分异,且不同海拔青海云杉径向生长的降水量制约趋势变得明显。研究表明,祁连山北坡青海云杉与气候的关系在海拔梯度上存在差异,其对气候变化的响应也存在差异,水分的限制作用随着温度的逐年升高逐渐突出;采用不同步长的样条函数去趋势可以在年表中保留不同的气候信息,从而对分异现象分析结果产生影响,选择合理步长的样条函数进行去趋势才能得到合理准确的分析结果。  相似文献   

10.
Erer KS 《Journal of biomechanics》2007,40(13):2934-2943
The Butterworth lowpass filter is a conventional tool that has been commonly used in gait analysis applications. Its operation mainly depends on the selection of the cut-off frequency, which must be done based on the condition of the raw signal assuming that it is stationary. This tool is unable to deal with nonstationary signals especially if impact is involved. In this paper, a modified version of the Butterworth filter that can handle nonstationary signals is presented. The new filter has a variable cut-off frequency distribution defined for each data point, which is determined by local signal characteristics. Because of its adaptive nature, it is possible for the filter to accommodate changes in the frequency content of the signal.  相似文献   

11.
The K+ (86Rb+) uptake and the growth of intact wheat seedlings ( Triticum aestivum L. cv. GK Szeged) grown in 0.5 m M CaCl2 solution and of seedlings grown on wet filter paper in Petri dishes were compared under different experimental conditions. Aeroponic (AP) and hydroponic (HP) conditions brought about striking differences in the growth of the roots, whereas the shoot growth was not influenced. The dry weight of the roots was higher for the AP plants than for the HP plants. The AP grown seedlings exhibit a low rate of K+ uptake, which seems to be a passive process. The effect of 2, 4–dinitrophenol (2, 4–DNP) clearly shows the absence of an active component of the K+ uptake in roots grown in air with a high relative humidity. In plants grown under AP conditions the effect of Ca2+ on the K+ uptake is unfavourable, i.e. there is an inhibition (negative Viets effect). Results relating to the effect of 2,4–DNP suggest that the "negative Viets effect" is a feature of the passive K+ uptake. The data suggest that the AP growth conditions play a very important role in the induction and/or development of the ion transport system(s), which becomes impaired under the AP conditions.  相似文献   

12.
Du C  Pan Y  MacGowan GA  Koretsky AP 《Cell calcium》2004,35(2):141-153
A strategy has been developed for the removal of motion artifact and noise in calcium-dependent fluorescence transients from the perfused mouse heart using frequency filtering. An analytical model indicates that the spectral removal of motion artifacts is independent of the phase shift of the motion waveform in the frequency domain, and thus to the time shift (or delay) of motion in the time domain. This is based on the "shift theorem" of Fourier analysis, which avoids erroneous correction of motion artifact when using the motion signal obtained using reflectance from the heart. Several major steps are adopted to implement this model for elimination of motion as well as detection noise from the fluorescence transient signals from the calcium-sensitive probe Rhod-2. These include (1) extracting the fluorescence calcium transient signal from the raw data by using power spectrum density (PSD) in the frequency domain by subtracting the motion recorded using the reflectance of excitation light, (2) digitally filtering out the random noise using multiple bandpass filters centralized at harmonic frequencies of the transients, and (3) extracting high frequency noise with a Gaussian Kernel filter method. The processed signal of transients acquired with excessive motion artifact is comparable to transients acquired with minimal motion obtained by immobilizing the heart against the detection window, demonstrating the usefulness of this technique.  相似文献   

13.
Trunk electromyographic signals (EMG) are often contaminated with heart muscle electrical activity (ECG) due to the proximity of the collection sites to the heart and the volume conduction characteristics of the ECG through the torso. Few studies have quantified ECG removal techniques relative to an uncontaminated EMG signal (gold standard or criterion measure), or made direct comparisons between different methods for a given set of data. Understanding the impacts of both untreated contaminated EMG and ECG elimination techniques on the amplitude and frequency parameters is vital given the widespread use of EMG. The purpose of this study was to evaluate four groups of current and commonly used techniques for the removal of ECG contamination from EMG signals. ECG recordings at two intensity levels (rest and 50% maximum predicted heart rate) were superimposed on 11 uncontaminated biceps brachii EMG signals (rest, 7 isometric and 3 isoinertial levels). The 23 removal methods used were high pass digital filtering (finite impulse response (FIR) using a Hamming window, and fourth-order Butterworth (BW) filter) at five cutoff frequencies (20, 30, 40, 50, and 60 Hz), template techniques (template subtraction and an amplitude gating template), combinations of the subtraction template and high pass digital filtering, and a frequency subtraction/signal reconstruction method. For muscle activation levels between 10% and 25% of maximum voluntary contraction, the template subtraction and BW filter with a 30 Hz cutoff were the two best methods for maximal ECG removal with minimal EMG distortion. The BW filter with a 30 Hz cutoff provided the optimal balance between ease of implementation, time investment, and performance across all contractions and heart rate levels for the EMG levels evaluated in this study.  相似文献   

14.
The pneumotachometer is currently the most accepted device to measure tidal breathing, however, it requires the use of a mouthpiece and thus alteration of spontaneous ventilation is implied. Respiratory inductive plethysmography (RIP), which includes two belts, one thoracic and one abdominal, is able to determine spontaneous tidal breathing without the use of a facemask or mouthpiece, however, there are a number of as yet unresolved issues. In this study we aimed to describe and validate a new RIP method, relying on a combination of thoracic RIP and nasal pressure signals taking into account that exercise-induced body movements can easily contaminate RIP thoracic signals by generating tissue motion artifacts. A custom-made time domain algorithm that relies on the elimination of low amplitude artifacts was applied to the raw thoracic RIP signal. Determining this tidal ventilation allowed comparisons between the RIP signal and simultaneously-recorded airflow signals from a calibrated pneumotachometer (PT). We assessed 206 comparisons from 30 volunteers who were asked to breathe spontaneously at rest and during walking on the spot. Comparisons between RIP signals processed by our algorithm and PT showed highly significant correlations for tidal volume (Vt), inspiratory (Ti) and expiratory times (Te). Moreover, bias calculated using the Bland and Altman method were reasonably low for Vt and Ti (0.04 L and 0.02 s, respectively), and acceptable for Te (<0.1 s) and the intercept from regression relationships (0.01 L, 0.06 s, 0.17 s respectively). The Ti/Ttot and Vt/Ti ratios obtained with the two methods were also statistically correlated. We conclude that our methodology (filtering by our algorithm and calibrating with our calibration procedure) for thoracic RIP renders this technique sufficiently accurate to evaluate tidal ventilation variation at rest and during mild to moderate physical activity.  相似文献   

15.
The surface electromyographic (sEMG) signal that originates in the muscle is inevitably contaminated by various noise signals or artifacts that originate at the skin-electrode interface, in the electronics that amplifies the signals, and in external sources. Modern technology is substantially immune to some of these noises, but not to the baseline noise and the movement artifact noise. These noise sources have frequency spectra that contaminate the low-frequency part of the sEMG frequency spectrum. There are many factors which must be taken into consideration when determining the appropriate filter specifications to remove these artifacts; they include the muscle tested and type of contraction, the sensor configuration, and specific noise source. The band-pass determination is always a compromise between (a) reducing noise and artifact contamination, and (b) preserving the desired information from the sEMG signal. This study was designed to investigate the effects of mechanical perturbations and noise that are typically encountered during sEMG recordings in clinical and related applications. The analysis established the relationship between the attenuation rates of the movement artifact and the sEMG signal as a function of the filter band pass. When this relationship is combined with other considerations related to the informational content of the signal, the signal distortion of filters, and the kinds of artifacts evaluated in this study, a Butterworth filter with a corner frequency of 20 Hz and a slope of 12 dB/oct is recommended for general use. The results of this study are relevant to biomechanical and clinical applications where the measurements of body dynamics and kinematics may include artifact sources.  相似文献   

16.
Biomechanical signals are represented in the time-frequency domain using the Wigner distribution function. Filtering of this representation for the case of a non-stationary displacement signal with impact is studied. Smoothed displacement data are then double differentiated and compared with references accelerometer data. It is shown that this technique is able to remove noise from these signals in a better way than conventional filtering techniques currently used in biomechanics.  相似文献   

17.
In biomechanical joint-motion analyses, the continuous motion to be studied is often approximated by a sequence of finite displacements, and the Finite Helical Axis (FHA) or "screw axis" for each displacement is estimated from position measurements on a number of anatomical or artificial landmarks. When FHA parameters are directly determined from raw (noisy) displacement data, both the position and the direction of the FHA are ill-determined, in particular when the sequential displacement steps are small. This implies, that under certain conditions, the continuous pathways of joint motions cannot be adequately described. The purpose of the present experimental study is to investigate the applicability of smoothing (or filtering) techniques, in those cases where FHA parameters are ill-determined. Two different quintic-spline smoothing methods were used to analyze the motion data obtained with Roentgenstereophotogrammetry in two experiments. One concerning carpal motions in a wrist-joint specimen, and one relative to a kinematic laboratory model, in which the axis positions are a priori known. The smoothed and non-smoothed FHA parameter errors were compared. The influences of the number of samples and the size of the sampling interval (displacement step) were investigated, as were the effects of equidistant and nonequidistant sampling conditions and noise invariance.  相似文献   

18.

Background

Haematuria has been traditionally considered as a benign hallmark of some glomerular diseases; however new studies show that haematuria may decrease renal function.

Objective

To determine the influence of haematuria on the rate of chronic kidney disease (CKD) progression in 71 proteinuric patients with advanced CKD (baseline eGFR <30 mL/min) during 12 months of follow-up.

Results

The mean rate of decline in eGFR was higher in patients with both haematuria and proteinuria (haemoproteinuria, HP, n=31) than in patients with proteinuria alone (P patients, n=40) (-3.8±8.9 vs 0.9±9.5 mL/min/1.73m2/year, p<0.05, respectively). The deleterious effect of haematuria on rate of decline in eGFR was observed in patients <65 years (-6.8±9.9 (HP) vs. 0.1±11.7 (P) mL/min/1.73m2/year, p<0.05), but not in patients >65 years (-1.2±6.8 (HP) vs. 1.5±7.7 (P) mL/min/1.73m2/year). Furthermore, the harmful effect of haematuria on eGFR slope was found patients with proteinuria >0.5 g/24 h (-5.8±6.4 (HP) vs. -1.37± 7.9 (P) mL/min/1.73m2/year, p<0.05), whereas no significant differences were found in patients with proteinuria < 0.5 g/24 h (-0.62±7.4 (HP) vs. 3.4±11.1 (P) mL/min/1.73m2/year). Multivariate analysis reported that presence of haematuria was significantly and independently associated with eGFR deterioration after adjusting for traditional risk factors, including age, serum phosphate, mean proteinuria and mean serum PTH (β=-4.316, p=0.025).

Conclusions

The presence of haematuria is closely associated with a faster decrease in renal function in advanced proteinuric CKD patients, especially in younger CKD patients with high proteinuria levels; therefore this high risk subgroup of patients would benefit of intensive medical surveillance and treatment.  相似文献   

19.
Nogueira J  Caputi ÁA 《PloS one》2011,6(7):e22159
Segmenting self- from allo-generated signals is crucial for active sensory processing. We report a dynamic filter used by South American pulse electric fish to distinguish active electro-sensory signals carried by their own electric discharges from other concomitant electrical stimuli (i.e. communication signals). The filter has a sensory component, consisting of an onset type central electro-sensory neuron, and a motor component, consisting of a change in the fish's discharge rate when allo-generated electrical events occur in temporal proximity to the fish's own discharge. We investigated the sensory component of the filter by in vitro mimicking synaptic inputs occurring during behavioral responses to allo-generated interfering signals. We found that active control of the discharge enhances self-generated over allo-generated responses by forcing allo-generated signals into a central refractory period. This hypothesis was confirmed by field potential recordings in freely discharging fish. Similar sensory-motor mechanisms may also contribute to signal segmentation in other sensory systems.  相似文献   

20.
Signals can be analyzed in either the time or frequency domain. In the time domain, the analysis consists of manipulating and measuring one or more characteristics of the signal that may vary with time. One can, for instance, rectify a signal, filter it, calculate its mean value, display the histogram of its amplitude, and so forth. Frequency analysis is less well understood because it requires a lengthy mathematical treatment most easily done by computer. However, it gives exclusive information on a signal. For instance, when the frequency content of a signal is known, it is easy to specify which characteristics an amplifier must have in order to amplify the signal without distortion, or to set the cutoff frequencies of filters to eliminate noise. Also, in many circumstances, frequency spectra are more easily interpreted than the original raw data. Such is the case with the EMG where the random aspect of the signal makes some form of processing (i.e., rectification, filtering, etc.) necessary, but not always as meaningful as we would like. Thus we present here the principal characteristics of frequency analysis, and discuss its usefulness in analyzing EMG signals and its application to biofeedback, clinical practice, and research.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号