共查询到20条相似文献,搜索用时 184 毫秒
1.
In a study of in vitro and in vivo metabolism of L-3,4-dihydroxyphenylalanine (L-Dopa), two methods of high-performance liquid chromatography (HPLC) were used to separate the m- and p-O-methylated products. A reversed-phase column and an aqueous mobile phase by gradient elution were used; the elute was analyzed electrochemically with a single amperometric and dual coulometric electrode. The L-Dopa and its O-methylated products could be detected individually in the enzymatic methylation of rat liver homogenate and in patients with Parkinson's disease. Meta/para ratios of O-methylation are easily obtained by this method. 相似文献
2.
Lina Long Douglas R. McCabe M. Eileen Dolan 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1999,731(2):128
A highly sensitive and selective method for determining 8-oxoguanine in plasma and urine was developed by high-performance liquid chromatography with electrochemical detection. The compound was separated by gradient elution on a C18 reversed-phase column with a mobile phase of acetonitrile and 0.1 M sodium acetate, pH 5.2. 8-Hydroxy-2′-deoxyguanosine was used as internal standard. 8-Oxoguanine was detected electrochemically by setting the potential to +300 mV vs. Pd reference. The sensitivity of the assay was 22 ng/ml with a signal-to-noise ratio of 7:1. The within-day relative standard deviations for 8-oxoguanine quality control samples with concentrations of 3340, 1340 and 84 ng/ml were 3.6, 4.3 and 5.7% for plasma, and 4.1, 4.6 and 6.2% for urine, respectively. The day-to-day relative standard deviations for the same samples were 3.8, 6.8 and 7.1% for plasma, and 3.9, 7.0 and 7.9% for urine, respectively. The method is designed to study the pharmacokinetics and metabolic fate of O6-benzylguanine in a phase I clinical trial. Previously, O6-benzyl-8-oxoguanine was identified as the primary metabolite of O6-benzylguanine in humans. We now demonstrate that 8-oxoguanine is a further metabolite of O6-benzylguanine. 相似文献
3.
Tatsuo Nakahara Makoto Hirano Takashi Matsumoto Toshihide Kuroki Yoshinori Tatebayashi Tetsuyuki Tsutsumi Kouji Nishiyama Hiroaki Ooboshi Kaoru Nakamura Hiroshi Yao Akio Shiraishi Michinori Waki Hideyuki Uchimura 《Neurochemical research》1990,15(6):609-611
DNA and RNA contents in 20 brain regions or nuclei of the rat were determined by a highly sensitive method using high-performance liquid chromatography with electrochemical detection. The high DNA and RNA contents were found in the hypothalamic nuclei, especially the median eminence-arcuate nucleus. These results may be available for the preparation of nucleic acids as the regional control. 相似文献
4.
The tripeptide glutathione (gamma-glutamylcysteinylglycine; GSH) is the predominant low molecular mass thiol in cells. The function of GSH is of considerable interest, with the molecule being implicated in numerous cellular processes in addition to being a major cellular antioxidant. The enzyme glutamate-cysteine ligase (GCL) is the rate-limiting step in GSH synthesis. The GCL assay described here is based on high-performance liquid chromatography and exploits the electrochemically active nature of gamma-glutamylcysteine (gamma-GC), the product of GCL activity. This method allows for the direct detection of gamma-GC rather than relying on derivatization of the molecule or linked assays. The sensitivity of the assay is sufficient to allow for the measurement of GCL activity in cultured cells. The specific activity of GCL in rat primary culture astrocytes was 9.7 +/- 1.7 nmol gamma-GC synthesized/min/mg protein. 相似文献
5.
Io Matsunaga Hideki Hakamata Kazuhiro Sadohara Kosuke Kakiuchi Fumiyo Kusu 《Analytical biochemistry》2009,393(2):222-228
A simple method for the determination of oxysterols was developed by semi-micro high-performance liquid chromatography with electrochemical detection (semi-micro HPLC–ECD). Semi-micro HPLC–ECD was established using a C30 microbore column, acetonitrile containing 50 mmol/L LiClO4 as a mobile phase, and an applied potential at +2.8 V versus Ag/AgCl. The current peak height was linearly related to the amount of sterol injected from 12.5 to 250 pmol (r > 0.999) with a relative standard deviation (RSD) of less than 2.9% (n = 6). This method was applied to the determination of seven oxysterols in oxidatively modified low-density lipoprotein (Ox–LDL). Oxysterols were determined with a recovery of more than 78.0% and an RSD of less than 2.9% (n = 6) except for 7-ketocholesterol. 7-Ketocholesterol was determined as a sum of intact 7-ketocholesterol and its degradation product on saponification, cholesta-3,5-dien-7-one, with a recovery of 98.0% and an RSD of 2.5% (n = 6). From these results, the current method enabled the simultaneous determination of seven oxysterols without any derivatization, providing a useful tool for the assessment of oxysterol contents in Ox–LDL. 相似文献
6.
Pia Lautala Ismo Ulmanen Jyrki Taskinen 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1999,736(1-2)
A new chromatographic catechol O-methyltransferase (COMT) assay based on S-adenosyl-
-[methyl-14C]methionine and on-line radioactivity detection was developed. With minor modifications in the mobile phase composition the methylation velocities for 30 structurally diverse compounds including simple catechols, neurotransmitters, catecholestrogens and catecholic drugs could be measured using human and rat recombinant soluble COMT. The enzymes showed very similar substrate selectivities. The radiochemical method was validated using 3,4-dihydroxybenzoic acid as a model substrate and it was shown that accurate and reproducible methylation velocity values could be achieved for both of the catecholic hydroxyls. The method proved to be suited for determining the enzyme kinetic parameters and can probably be further used for gathering enzyme kinetic data on differentially substituted catechols in order to construct proper structure-activity relationships for COMT. 相似文献
7.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1995,672(1):73-80
Low-molecular-mass thiols, such as glutathione (GSH), and their associated disulfides are ubiquitous in nature, and based upon the many known functions of these compounds, their identification and accurate measurement is essential. Our objectives were to develop a simple method for the simultaneous measurement of thiols and disulfides in biological samples using HPLC with dual electrochemical detection (HPLC-DED). Particular emphasis was placed on the applicability to a wide variety of important GSH-related thiols and disulfides, including γ-Glu-Cys, Cys-Gly, their disulfides, and the mixed disulfide of glutathione and cysteine (CSSG), validation on different types of biological samples, maintenance of chromatographic resolution and reproducibility with routine and extended use, and enhancement of assay sensitivity. To this end, optimal HPLC conditions including mobile phase, column, and electrode polishing procedures were established and the method was applied to, and validated on a variety of biological samples. This improved methodology should prove to be a useful tool in studies on the metabolism of GSH and other thiols and disulfides and their role in cellular homeostasis and disease processes. 相似文献
8.
A method for the determination of cholecystokinins in biological material, based on high-pressure liquid chromatography with direct electrochemical detection (HPLC-EC), is described. Using this method, the levels of cholecystokinin tetrapeptide and octapeptide sulfate in rat brain cortex, hippocampus, striatum, and brain stem were measured and found to be comparable to those reported using radioimmunoassay methods. We show that HPLC-EC is sensitive enough to accurately determine neuropeptides in brain tissue without prior derivatization and is therefore, due to its simplicity, an attractive alternative to existing methods. 相似文献
9.
An improved high-performance liquid chromatographic method with electrochemical detection (HPLC-EC) for the simultaneous determination of 3-methoxy-4-hydroxyphenylglycol (MHPG), 5-hydroxyindoleacetic acid (5-HIAA), and homovanillic acid (HVA) in cerebrospinal fluid (CSF) of humans and nonhuman primates is described. Quantitation is based on the use of an internal standard, 5-fluoro-HVA. Sample preparation consists of mixing an aliquot of CSF with a solution of the internal standard followed by ultrafiltration. The precision of the method is high, with within-run and between-run coefficients of variation of 2-6% and less than 10%, respectively, in the concentration ranges of the metabolites encountered in human lumbar CSF. Accuracy was tested by comparing the present HPLC method with specific gas chromatographic-mass spectrometric (GS-MS) assays for MHPG and HVA and a GC-MS-validated HPLC assay for 5-HIAA: the correlations obtained were 0.968 for MHPG, 0.989 for 5-HIAA, and 0.999 for HVA, with no systematic bias between the methods. The use of ascorbate as a preserving agent for monoamine metabolites in CSF was not found to be necessary when proper care was exercised in sample handling and storage. The analysis of samples with up to 2% ascorbic acid was possible as well, but MHPG had to be assayed separately using an extraction procedure and an alternative internal standard, 3-ethoxy-4-hydroxyphenylglycol. 相似文献
10.
Wun-Chang Ko Jen-Yen Yang Chi-Ming Chen 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1996,685(2):1975
An HPLC assay is described for the determination of Z-butylidenephthalide (Z-Bdph) in plasma. Plasma samples were cleaned up by extraction with 2% chloroform in n-hexane. Z-Bdph was separated on a normal-phase silica column with a mobile phase of chloroform-n-hexane (1:1). The limit of quantitation with UV detection at 254 nm for Z-Bdph in plasma was 0.01 μg/ml. The recovery of Z-Bdph by organic solvent extraction of plasma was 99.5%. The intra-day and inter-day coefficients of variation and relative errors for Z-Bdph determination in plasma were both less than 10%. The present method was applied to pharmacokinetic studies of Z-Bdph in plasma after intravenous administration to rabbits. 相似文献
11.
Zhimeng Zhu Gia Klironomos Andre Vachereau Len Neirinck David W. Goodman 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1999,724(2):640
The first method using high-performance liquid chromatography (HPLC) has been developed for the determination of trans-resveratrol in human plasma. The method involves a liquid–liquid extraction followed by reversed-phase HPLC with UV detection. The detection limit of trans-resveratrol in human plasma was 5.0 ng/ml. Standard curves are linear over the concentration range of 5.0–5000.0 ng/ml. Intra-assay variability ranged from 1.9 to 3.7% and inter-assay variability ranged from 2.5 to 4.0% at the concentration range of 15.0–4000.0 ng/ml. 相似文献
12.
Elena D. Katz 《Molecular biotechnology》1996,6(1):79-86
This work describes the application of the fully automated high-performance liquid chromatographic system to the analysis
of PCR-amplified products. Efficient separations of both DNA restriction fragments and PCR products were performed using an
anion-exchange DEAE-NPR column, packed with 2.5-μm nonporous particles. The automated HPLC method was employed for the separation,
quantitation, and purification of PCR products in less than 10 min in a single step. 相似文献
13.
14.
Emson C. Nyoni Balvant R. Sitaram David A. Taylor 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1996,679(1-2)
Δ9-Tetrahydrocannabinol (Δ9-THC) is the major psychoactive component of cannabis. To assist in investigating the mechanism(s) of action of Δ9-THC, a convenient method for determining its levels in brain tissue is required. We now describe a method for determining nanogram quantities of Δ9-THC in rat brain tissue. The method employs solvent extraction with methanol-hexane-ethyl acetate, followed by analysis using liquid chromatography with electrochemical detection. Overall recoveries were greater than 80%. The relationship between the peak-height ratio for processed standards extracted in the presence of tissue (Δ9-THC/internal standard) and the amount of Δ9-THC added was shown to be linear within the range of concentrations examined. Quantitative measurements of Δ9-THC in different brain regions following the intravenous administration of Δ9-THC are presented as examples of the applications of this method. 相似文献
15.
16.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1997,694(1):185-191
A sensitive method has been developed for the determination of hydroxyurea in plasma and peritoneal fluid using reversed-phase high-performance liquid chromatography (HPLC) with electrochemical detection. Plasma or peritoneal fluid samples were treated with acetonitrile to precipitate proteins then injected to the HPLC. A C18 analytical column was used to separate hydroxyurea from interfering substances in the biological matrix. The mobile phase, consisting of 0.2 M sodium perchlorate–methanol (95:5, v/v) adjusted to pH 5.0, was delivered isocratically at a flow-rate of 1 ml/min and hydroxyurea was detected using a glassy-carbon electrode operating at an applied potential of +800 mV. Hydroxyurea eluted with a retention time of 3 min. The cycle time for analysis is short and the assay precision is acceptable (C.V. plasma=1.4–3.9%, C.V. peritoneal fluid=2.1–9.7%). The method has been validated and is linear from 25 to 400 ng/ml in plasma and 5 to 30 ng/ml in peritoneal fluid. The method has been shown to be applicable for pharmacokinetic studies. 相似文献
17.
Michael Brunnenberg Hiltrud Lindenblatt Euphrosyne Gouzoulis-Mayfrank Karl-Artur Kovar 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1998,719(1-2)
A HPLC method has been developed for the analogue of Ecstasy MDE and its major metabolites N-ethyl-4-hydroxy-3-methoxyamphetamine (HME) and 3,4-methylenedioxyamphetamine (MDA) in human plasma. In the course of our investigations we found that the methylenedioxyamphetamines and HME exhibit fluorescence at 322 nm. Therefore the detection could be carried out with a fluorescence (FL) detector. Solid-phase extraction was used for sample preparation and yielded high recovery rates greater than 95%. The limit of quantitation for MDE and its metabolites in the extracts was between 1.5 and 8.9 ng/ml and the method standard deviations were less than 5%. This sensitive, rapid and reliable analytical method has been used successfully in the quantitation of the substances in plasma samples obtained from 14 volunteers in two clinical studies after p.o. administration of 100 to 140 mg MDE*HCl. The maximum plasma concentrations were 235–465 ng/ml (MDE), 67–673 ng/ml (HME) and 7–33 ng/ml (MDA), respectively. Pharmacokinetic parameters have been investigated using the plasma concentration curves. 相似文献
18.
Panayotis A. Siskos Maria-Helen E. Spyridaki 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1999,724(2):346
A simple, rapid and sensitive reversed-phase ion-pair high-performance liquid chromatographic method for the determination of N-acetylneuraminic acid and 2-deoxy-2,3-dehydro-N-acetylneuraminic acid in biological fluids is described. Determination of N-acetylneuraminic acid released by acidic hydrolysis, in serum, urine and saliva, and 2-deoxy-2,3-dehydro-N-acetylneuraminic acid in urine, without hydrolysis, was accomplished by injecting the sample without derivatization, into the chromatograph. Measurements were carried out isocratically within 6 min using a C18 column and a mobile phase of aqueous solution of triisopropanolamine, as ion-pair reagent, 60 mM, pH 3.5 at room temperature with UV absorbance detection. The present method is reported for the first time for the determination of sialic acids in biological fluids. Recoveries in serum, urine and saliva ranged from 90 to 102% and the limits of detection were 60 nM and 20 nM for the two sialic acids, respectively. The method has been applied to normal and pathological sera from patients with breast, stomach, colon, ovarian and cervix cancers, to normal urine and urine from patient with sialuria and to normal saliva. 相似文献
19.
R. Di Giovannandrea L. Diana M. Fiori E. Ferretti G. Foglietta R. Caronna G. Severini 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2001,751(2)
We have developed a high-performance liquid chromatographic–UV–Vis–diode-array detection (HPLC–DAD) method for the determination of ethyl-p-hydroxybenzoate, a hydrolytic degradation product of the synthetic protease inhibitor, gabexate-mesilate ethyl-p-(6-guanidinohexanoyloxy) benzoate methanesulfonate (GM) (FOY) in sow pancreatic juice. Methyl-p-hydroxybenzoate (I) was used as the internal standard. The pancreatic juice was deproteinised by acetonitrile and the analytes were chromatographed on a reversed-phase C18 LC column using the gradient elution method. The mobile phase consisted of a solution of 0.017 M orthophosphoric acid and another solution of acetonitrile–water (80:20, v/v). The wavelength of detection was 237 nm. The limit of quantification of the method was 0.20 μM at a 9:1 signal-to-noise ratio. The overall intra- and inter-day accuracy (relative error, RE) ranged from 14.2 to 8.3% and from 13.3 to 9.8, respectively. The overall intra- and inter-day precision (relative standard deviation, RSD) ranged from 7.6 to 2.62% and from 6.7 to 3.1%, respectively. The method proved to be sensitive, specific, accurate and precise and was successfully used to determine the ethyl-p-hydroxybenzoate (II) in sow pancreatic juice. 相似文献
20.
L Bianchi M.A Colivicchi L Della Corte M Valoti G.P Sgaragli P Bechi 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1997,694(2):607
The antioxidants, 2-tert.-butyl-4-methoxyphenol (BHA) and its oxidative peroxidation product 2,2′-dihydroxy-3,3′-di-tert.-butyl-5,5′-dimethoxybiphenyl (di-BHA), 3,5-di-tert.-butyl-4-hydroxytoluene (BHT) and propyl gallate, were measured in plasma and tissue homogenates by HPLC and electrochemical detection, with a sensitivity down to 0.2 (BHA), 0.1 (di-BHA), 0.4 (BHT) and 1 (propyl gallate) ng ml−1 of plasma or tissue homogenate. The data demonstrate that in man, at the current level of exposure to dietary antioxidants, significant amounts of BHA, BHT and propyl gallate are accumulated in the omentum. Furthermore, they provide the first evidence that the peroxidase-catalysed oxidation of BHA is operative in man. 相似文献