首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An HPLC method for the simultaneous determination of both caffeine and theophyllie in human plasma is described, using a reversed-phase chromatography column, heated by a thermostatic oven at 35°C, with UV detection and isocratic elution. The linearity and reproducibility of the method are verified. For the two drugs, the limit of detection is 0.1 μg ml−1. This analytical method is rapid and reliable and allows routine controls of therapeutic levels of theophylline and caffeine, especially in premature infants where the volume of plasma samples is very small.  相似文献   

2.
Determination of

A simple, rapid and sensitive two column-switching high-performance liquid chromatographic (HPLC) method with ultraviolet detection at 210 nm has been developed for the determination of

(AY4166, I) and its seven metabolites in human plasma and urine. Measurements of I and its metabolites were carried out by two column-switching HPLC, because metabolites were classified into two groups according to their retention times. After purification of plasma samples using solid-phase extraction and direct dilution of urinary samples, I and each metabolite were injected into HPLC. The calibration graphs for plasma and urinary samples were linear in the ranges 0.1 to 10 μg ml−1 and 0.5 to 50 μg ml−1, respectively. Recoveries of I and its seven metabolites were over 88% by the standard addition method and the relative standard deviations of I and its metabolites were 1–6%.  相似文献   

3.
An HPLC method has been developed and validated for the determination of spironolactone, 7 alpha-thiomethylspirolactone and canrenone in paediatric plasma samples. The method utilises 200 microl of plasma and sample preparation involves protein precipitation followed by Solid Phase Extraction (SPE). Determination of standard curves of peak height ratio (PHR) against concentration was performed by weighted least squares linear regression using a weighting factor of 1/concentration2. The developed method was found to be linear over concentration ranges of 30-1000 ng/ml for spironolactone and 25-1000 ng/ml for 7 alpha-thiomethylspirolactone and canrenone. The lower limit of quantification for spironolactone, 7 alpha-thiomethylspirolactone and canrenone were calculated as 28, 20 and 25 ng/ml, respectively. The method was shown to be applicable to the determination of spironolactone, 7 alpha-thiomethylspirolactone and canrenone in paediatric plasma samples and also plasma from healthy human volunteers.  相似文献   

4.
The bioavailability of oral and intravenous cimetidine and ranitidine was studied in patients with compensated liver cirrhosis. Single doses of 200 and 400 mg cimetidine were used for both administration routes, while ranitidine was administered in doses of 150 mg orally or 50 mg i.v. Plasma concentrations and urinary recovery were determined by the HPLC method. The pharmacokinetics of both of these drugs in the cirrhotic patients did not differ from those found in normal subjects. The two doses of cimetidine given i.v. gave rise to the same plasma concentrations, while after oral administration, 400 mg produced higher plasma concentrations than 200 mg. As to the pharmacokinetic parameters, neither cimetidine nor ranitidine administered i.v. offered any further advantages compared to the oral route. The urinary recovery of both cimetidine and ranitidine was higher after intravenous than after oral administration. It is concluded therefore that the pharmacokinetics of cimetidine and ranitidine is not altered in compensated liver cirrhosis.  相似文献   

5.
A method for the simultaneous determination of cefotaxime (CTX) and desacetylcefotaxime (DES) in plasma was developed, using acetonitrile protein precipitation and high-performance liquid chromatography (HPLC) with UV-detection at 285 nm. Desacetylcefotaxime was also analysed after conversion in highly acidic medium to its lactone form (DES-lactone). The chromatographic separation was performed on a C18 Aqua column. The lower limit of quantitation was 1 microg/ml for CTX and 0.5 microg/ml for DES and DES-lactone, using 25 microl of plasma samples. The linearity of the calibration curves was satisfactory as indicated by correlation coefficients of > or =0.990. The within-day and between-day precisions were <12% (n = 18) for the two products and the accuracy was between 88 and 101%. The developed HPLC method was applied for CTX and DES determination in plasma samples of critically ill patients after continuous intravenous infusion of CTX.  相似文献   

6.
Indomethacin and mefenamic acid are widely used clinically as non-steroidal anti-inflammatory agents. Both drugs have also been found effective to produce closure of patent ductus arteriosus in premature neonates. A simple, rapid, sensitive and reliable HPLC method is described for the determination of indomethacin and mefenamic acid in human plasma. As these drugs are not applied together, the compounds are alternately used as analyte and internal standard. Plasma was deproteinized with acetonitrile, the supernatant fraction was evaporated to dryness and the resulting residue was reconstituted in the mobile phase and injected into the HPLC system. The chromatographic separation was performed on a C18 column (250 × 4.6 mm I.D.) using 10 mM phosphoric acid—acetonitrile (40:60, v/v) as the mobile phase and both drugs were detected at 280 nm. The calibration graphs were linear with a correlation coefficient (r) of 0.999 or better from 0.1 to 10 μg/ml and the detection limits were 0.06 μg/ml for indomethacin and 0.08 μg/ml for mefenamic acid, for 50μl plasma samples. The method was not interfered with by other plasma components and has been found particularly useful for paediatric use. The within-day precision and accuracy of the method were evaluated for three concentrations in spiked plasma samples. The coefficients of variation were less than 5% and the accuracy was nearly 100% for both drugs.  相似文献   

7.
We established a high-performance liquid chromatography (HPLC) method for the simultaneous determination of the camptothecin (CPT) derivative, irinotecan hydrochloride (CPT-11) and its metabolites, 7-ethyl-10-hydroxycamptothecin (SN-38) and SN-38 glucuronide (SN-38G) in rat plasma with a fully automated on-line solid-phase extraction system, PROSPEKT. Plasma samples were pretreated with 0.146 M H3PO4 to inactivate carboxylesterase and β-glucuronidase in rat plasma, and added with the internal standard solution (0.146 M H3PO4 containing 1 μg/ml CPT) and then analyzed. The method was validated for CPT-11 (5 to 25 000 ng/ml), SN-38 (5 to 2500 ng/ml) and SN-38G (2.5 to 500 ng/ml). This method enabled the determination of many samples within a relatively short time with easy sample preparation. It also had four advantages compared with conventional determination methods, i.e. automation of a complicated sample preparation, time-saving by the simultaneous determination of three compounds, the direct determination of SN-38G, and the small amount of plasma required for the determination.  相似文献   

8.
This paper reports the MEPS-HPLC-DAD method for the simultaneous determination of 12 azole drugs (bifonazole, butoconazole, clotrimazole, econazole, itraconazole, ketoconazole, miconazole, posaconazole, ravuconazole, terconazole, tioconazole and voriconazole) administered to treat different systemic and topical fungal infections, in biological samples. Azole drugs separation was performed in 36?min. The analytical method was validated in the ranges as follows: 0.02–5?μg mL?1 for ravuconazole; 0.2–5?μg mL?1 for terconazole; 0.05–5?μg mL?1 for the other compounds. Human plasma and urine were used as biological samples during the analysis, while benzyl-4-hydroxybenzoate was used as an internal standard. The precision (RSD%) and trueness (Bias%) values fulfill with International Guidelines requirements. To the best of our knowledge, this is the first HPLC-DAD procedure coupled to MEPS, which provides the simultaneous analysis of 12 azole drugs, available in the market, in human plasma and urine. Moreover, the method was successfully applied for the quantitative determination of two model drugs (itraconazole and miconazole) after oral administration in real samples.  相似文献   

9.
A method for the simultaneous direct determination of salicylate (SA), its labile, reactive metabolite, salicyl acyl glucuronide (SAG), and two other major metabolites, salicyluric acid and gentisic acid in plasma and urine is described. Isocratic reversed-phase high performance liquid chromatography (HPLC) employed a 15-cm C18 column using methanol-acetonitrile-25 mM acetic acid as the mobile phase, resulting in HPLC analysis time of less than 20 min. Ultraviolet detection at 310 nm permitted analysis of SAG in plasma, but did not provide sensitivity for measurement of salicyl phenol glucuronide. Plasma or urine samples are stabilized immediately upon collection by adjustment of pH to 3–4 to prevent degradation of the labile acyl glucuronide metabolite. Plasma is then deproteinated with acetonitrile, dried and reconstituted for injection, whereas urine samples are simply diluted prior to injection on HPLC. m-Hydroxybenzoic acid served as the internal standard. Recoveries from plasma were greater than 85% for all four compounds over a range of 0.2–20 μg/ml and linearity was observed from 0.1–200 μg/ml and 5–2000 μg/ml for SA in plasma and urine, respectively. The method was validated to 0.2 μg/ml, thus allowing accurate measurement of SA, and three major metabolites in plasma and urine of subjects and small animals administered salicylates. The method is unique by allowing quantitation of reactive SAG in plasma at levels well below 1% that of the parent compound, SA, as is observed in patients administered salicylates.  相似文献   

10.
Methadone and buprenorphine are two of the drugs most frequently used for abstinence from illicit opioids and in the treatment of pain. A sensitive and selective high-performance liquid chromatographic method with diode array detection for the simultaneous determination of methadone, buprenorphine and norbuprenorphine has been developed. Separation of the three analytes was obtained by using a reversed-phase column (C8, 250mmx4.6mm i.d., 5microm) and a mobile phase composed of 40% phosphate buffer containing triethylamine, 50% methanol and 10% acetonitrile (final apparent pH 6.0). Loxapine was used as the internal standard. An accurate pre-treatment procedure of biological samples was developed, using solid-phase extraction with C8 cartridges (100mg, 1mL) and needing small amounts of plasma or urine (300microL). The calibration curves were linear over a working range of 10.0-1500.0ng/mL for methadone and of 5.0-500.0ng/mL for buprenorphine and norbuprenorphine in both matrices. The limit of quantitation (LOQ) and the limit of detection (LOD) were 1.0 and 0.4ng/mL for methadone and 0.5 and 0.2ng/mL for both buprenorphine and norbuprenorphine, respectively. The method was successfully applied to the analysis of plasma and urine samples from patients undergoing treatment with these drugs. Precision and accuracy results were satisfactory and no interference from endogenous or exogenous compounds was found. The method is suitable for the simultaneous determination of methadone and buprenorphine in human plasma and urine for therapeutic drug monitoring purposes.  相似文献   

11.
An improved high-performance liquid chromatographic (HPLC) method utilizing solid-phase extraction (SPE) and midbore chromatography was developed for the determination of ranitidine in human plasma. A mobile phase of 20 mM K2HPO4-acetonitrile-triethylamine (87.9:12.0:0.1, v/v) pH 6.0 was used with a phenyl analytical column and ultraviolet detection (UV). The method demonstrated linearity from 25 to 1000 ng/ml in 500 μl of plasma with a detection limit of 10 ng/ml. The method was utilized in a pharmacokinetic study evaluating the effects of pancreatico-biliary secretions on ranitidine absorption.  相似文献   

12.
Ranitidine and its main metabolites, ranitidine N-oxide and ranitidine S-oxide, were determined in plasma and urine after separation using reversed-phase liquid chromatography. The mobile phase consisted of an initial isocratic step with 7:93 (v/v) acetonitrile–7.5 mM phosphate buffer (pH 6) for 8 min, followed by a linear gradient up to a 25:75 (v/v) mixture over 1 min. Detection was carried out by a post-column fluorimetric derivatization based on the reaction of the drugs with sodium hypochlorite, giving rise to primary amines that reacted with o-phthalaldehyde and 2-mercaptoethanol to form highly fluorescent products. The calibration graphs, based on peak area, were linear in the range 0.1–4 μg/ml for all drugs. The detection limits were 30, 41 and 32 ng/ml (8.6, 12.5 and 9.1 pmol) for ranitidine S-oxide, ranitidine N-oxide and ranitidine, respectively. Chromatographic profiles obtained for plasma and urine samples showed no interference from endogenous compounds.  相似文献   

13.
Reversed-phase HPLC procedures were developed for the determination of tolcapone (Ro 40-7592) and its metabolites Ro 40-7591, Ro 61-1448, and Ro 47-1669 in plasma and in urine samples. One of the procedures for plasma involved the determination of tolcapone and its metabolite Ro 40-7591 and the other, the determination of the two other metabolites. The urine assay enabled the simultaneous determination of tolcapone and all metabolites in one run. Sample preparation in plasma involved protein precipitation with acetonitrile. Urine was simply diluted. The compounds of interest were monitored in the UV at 270 nm. The limits of quantification were 0.05 μg/ml for each compound (plasma assay) and 0.2 μg/ml for the urine assay. The mean inter-assay precisions (C.V.) were ≤6% (plasma assay) and ≤8% (urine assay). The procedures were successfully applied to the sample analysis of animal pharmacokinetic (rat, dog, mouse, rabbit and cynomolgus monkey) and clinical pharmacology studies.  相似文献   

14.
A validated, simple and universal HPLC-UV method for the determination of cimetidine, famotidine, nizatidine and ranitidine in human urine is presented. This is the first single HPLC method reported for the analysis of all four H(2) antagonists in human biological samples. This method was also utilized for the analysis of ranitidine and its metabolites in human urine. All calibration curves showed good linear regression (r(2)>0.9960) within test ranges. The method showed good precision and accuracy with overall intra- and inter-day variations of 0.2-13.6% and 0.2-12.1%, respectively. Separation of ranitidine and its metabolites using this assay provided significantly improved resolution, precision and accuracy compared to previously reported methods. The assay was successfully applied to a human volunteer study using ranitidine as the model compound.  相似文献   

15.
A method is described for the qualiitative and quantitative determination of phenylbutazone and oxyphenbutazone in horse urine and plasma samples viewing antidoping control. A horse was administered intravenously with 3 g of phenylbutazone. For the qualitative determination, a screening by HPLC was performed after acidic extraction of the urine samples and the confirmation process was realized by GC-MS. Using the proposed method it was possible to detect phenylbutazone and oxyphenbutazone in urine for up to 48 and 120 h, respectively. For the quantitation of these drugs the plasma was deproteinized with acetonitrile and 20 gml were injected directly into the HPLC system equipped with a UV detector and LiChrospher RP-18 column. The mobile phase used was 0.01 M acetic acid in methanol (45:55, v/v). The limit of detection was 0.5 μg/ml for phenylbutazone and oxyphenbutazone and the limit of quantitation was 1.0 μg/ml for both drugs. Using the proposed method it was possible to quantify phenylbutazone up to 30 h and oxyphenbutazone up to 39 h after administration.  相似文献   

16.
A sensitive high-performance liquid chromatographic method for determination of ranitidine (RAN) in rabbit plasma is described. The method is based on liquid-liquid extraction, labeling with dansyl chloride and monitoring with fluorescence detector at 338nm (ex)/523nm (em). Plasma samples were extracted with diethyl ether alkalinized with 1M sodium hydroxide. Ephedrine HCl (EPH-HCl) was used as internal standard. Both, RAN and EPH were completely derivatized after heating at 60 degrees C for 10min in sodium bicarbonate solution (pH 9.5). The derivatized samples were analyzed by HPLC using Agilent Zorbax Extended C18 column (150mmx4.6mm i.d.) and mobile phase consists of 48% acetonitrile and 52% sodium acetate solution (0.02M, pH 4.6). The linearity of the method was in the range of 0.025-10microg/ml. The limits of detection (LOD) and quantification (LOQ) were 7.5+/-0.18 and 22.5+/-0.12ng/ml, respectively. Ranitidine recovery was 97.5+/-1.1% (n=6; R.S.D.=1.8%). The method was applied on plasma collected from rabbits at different time intervals after oral administration of 5mg/kg ranitidine HCl.  相似文献   

17.
A simple and sensitive column-switching HPLC method has been developed for the simultaneous determination of NK-104 (HMG–CoA reductase inhibitor) and its lactone in human and dog plasma. Plasma sample was extracted with methyl tert-butyl ether and then the extract was subjected to methylation with diazomethane to prevent the mutual conversion between NK-104 and its lactone. The extract was injected into the column-switching HPLC system. The calibration curves of NK-104 and NK-104 lactone were linear over the ranges 0.5 to 100 ng/ml for human plasma samples and 0.5 to 500 ng/ml for dog plasma, respectively. The intra-day and inter-day C.V. values of these analytes were less than 13.3%. The intra-day and inter-day accuracies of these analytes were between −14.0 and 6.5%. The proposed method has been applied to plasma samples obtained after oral administration of a single 2 mg dose of NK-104 to volunteers.  相似文献   

18.
A new HPLC method for the simultaneous determination of celecoxib, carboxycelecoxib and hydroxycelecoxib in human plasma samples has been developed. Following a solid-phase extraction procedure, the samples were separated by gradient reversed-phase HLPC (C(18)) and quantified using UV detection at 254 nm. The method was linear over the concentration range 10-500 ng/ml. The intra-assay variability for the three analytes ranged from 4.0 to 12.6% and the inter-assay variability from 4.9 to 14.2%. The achieved limits of quantitation (LOQ) of 10 ng/ml for each analyte allowed the determination of the pharmacokinetic parameters of the analytes after administration of 100 mg celecoxib.  相似文献   

19.
Increased oxidative stress has emerged as a potential mechanism implicated in the pathogenesis, progression and cell dysfunction associated with many diseases including diabetes. In routine clinical practice, the estimation of the degree of oxidative damage and antioxidant status, even in paediatric patients, by appropriate techniques appears to be of interest. The aim of this study was to reliably identify patients with increased oxidant stress and/or reduced antioxidant defence mechanisms with a small blood sample and verify the applicability to the study of diabetic children (DC) at clinical onset of the disease. In 1-ml blood samples from 30 DC and 34 controls, techniques for accurately measuring malondialdehyde (MDA) concentrations in plasma and erythrocytes (using HPLC analysis with fluorometric detection), total radical antioxidant potential (TRAP) and blood plasma oxidizability were adapted and validated. Plasma alpha-tocopherol (HPLC), uric acid and sulfhydryl (SH) groups were also determined. At clinical onset of diabetes a significant reduction in plasma TRAP values (P<0.01) was observed in DC compared with controls. Similarly, a significant fall in individual antioxidant levels (alpha-tocopherol/total lipids, uric acid and protein SH) was noted in plasma of DC. Highly significant increases were found in both plasma and erythrocyte MDA levels in DC (p-MDA:1.7+/-0.2 microM; er-MDA: 7.2+/-0.7 nmol/g Hb) compared with controls (p-MDA:0.86+/-0.09 microM; P<0.0003; er-MDA:3.8+/-0.2 nmol/g Hb, P<0.0001). Plasma MDA and triglyceride levels correlated directly only in DC (P<0.001). Whole plasma oxidizability was significantly higher in DC than in controls (P<0.0001) and this parameter correlated significantly with plasma cholesterol and triglyceride concentrations (P<0.0001). The micromethods adapted and applied to the simultaneous detection of lipid peroxidation products and antioxidant status permit accurate and reliable assessment of the oxidative stress process in small plasma samples. Our results clearly show systemic peroxidative damage associated with insufficient defence mechanisms against ROS to be already present at clinical onset of type 1 diabetes mellitus in children and adolescents.  相似文献   

20.
A reversed-phase high-performance liquid chromatographic assay for the simultaneous determination of phenytoin and fosphenytoin, a prodrug for phenytoin, in human plasma and plasma ultrafiltrate is described. For plasma, the method involves simple extraction of drugs with diethyl ether and evaporation of solvent, followed by injection of the reconstituted sample onto a reversed-phase C18 column. Plasma ultrafiltrate is injected directly into the HPLC column. Compounds are eluted using an ion-pair mobile phase containing 20% acetonitrile. The eluent is monitored by UV absorbance at 210 nm. The fosphenytoin standard curves are linear in the concentration range 0.4 to 400 μg/ml for plasma and 0.03 to 80 μg/ml for ultrafiltrate. Phenytoin standard curves are linear from 0.08 to 40 μg/ml for plasma and from 0.02 to 5.0 μg/ml for ultrafiltrate. No interferences with the assay procedure were found in drug-free blank plasma or plasma ultrafiltrate. Relative standard deviation for replicate plasma or ultrafiltrate samples was less than 5% at concentrations above the limit of quantitation for both within- and between-run calculations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号