1.
We examined the effect of an electric field strength gradient on DNA sequencing efficiency using capillary array electrophoresis. Several types of gradients were applied to DNA sequencing and tested in terms of read length and accuracy. Our original method improved the accuracy of DNA sequencing for longer fragments at high temperature.  相似文献   

2.
Nucleoprotein particles (B2), isolated following digestion of calf thymus chromatin with micrococcal nuclease, are resolved on a non-chelating Bio-Gel A-5m column. B2 protein electrophoresis showed the presence of several H1 species and several nonhistone proteins but was depleted in core histones. DNA electrophoresis demonstrated that native B2 DNA has a length of about 46 base pairs. On DNA sequencing gels, the length distribution of denatured B2 DNA ranged from 12 to 35 bases with a weighted average chain length of about 26 bases. Depletion of a 20 base band in B2 DNA suggested specific protection of internucleosomal DNA sites during the nuclease digestion.  相似文献   

3.
Free-solution conjugate electrophoresis (FSCE) is a method of DNA sequencing that eliminates the need for viscous polymer solutions by tethering a carefully designed, mobility modifying "drag-tag" to each DNA molecule to achieve size-based separations of DNA. The most successful drag-tags to date are genetically engineered, highly repetitive polypeptides ("protein polymers") that are designed to be large, water-soluble, and completely monodisperse. Positively charged arginines were deliberately introduced at regular intervals into the amino acid sequence to increase the hydrodynamic drag without increasing drag-tag length. Additionally, a one-step purification method that combines affinity chromatography and on-column tag cleavage was devised to achieve the required drag-tag monodispersity. Sequencing with a read length of approximately 180 bases was successfully achieved with a known sequence in free-solution electrophoresis using one of these positively charged drag-tags. This preliminary result is expected to lead to further progress in FSCE sequencing with ~400 bases read length possible when more "highly" positively charged protein polymers of larger size are generated with the intein system.  相似文献   

4.
Purification of microbial DNA from soil is challenging due to the co-extraction of humic acids and associated phenolic compounds that inhibit subsequent cloning, amplification or sequencing. Removal of these contaminants is critical for the success of metagenomic library construction and high-throughput sequencing of extracted DNA. Using three different composite soil samples, we compared a novel DNA purification technique using nonlinear electrophoresis on the synchronous coefficient of drag alteration (SCODA) instrument with alternate purification methods such as direct current (DC) agarose gel electrophoresis followed by gel filtration or anion exchange chromatography, Wizard DNA Clean-Up System, and the PowerSoil DNA Isolation kit. Both nonlinear and DC electrophoresis were effective at retrieving high-molecular weight DNA with high purity, suitable for construction of large-insert libraries. The PowerSoil DNA Isolation kit and the nonlinear electrophoresis had high recovery of high purity DNA suitable for sequencing purposes. All methods demonstrated high consistency in the bacterial community profiles generated from the DNA extracts. Nonlinear electrophoresis using the SCODA instrument was the ideal methodology for the preparation of soil DNA samples suitable for both high-throughput sequencing and large-insert cloning applications.  相似文献   

5.
辣椒疫霉(Phytophthora copsici)毒素的产生是由一个不完全显性基因所控制,通过RAPD/BSA分析证明,用OPW12扩增得到一条约1300bp的RAPD标记带,该带与辣椒疫霉产毒共分离。纯化回收OPW12 1300DNA,共转化感受态E.coli DH5a,筛选出3个白色阳性克隆,序列分析发现该标记DNA为1291bp。这一标记DNA序列的阐明为进一分析产毒遗传机理提供了新的信息。  相似文献   

6.
辣椒疫霉(Phytophthora copsici)毒素的产生是由一个不完全显性基因所控制,通过RAPD/BSA分析证明,用OPW12扩增得到一条约1300bp的RAPD标记带,该带与辣椒疫霉产毒共分离。纯化回收OPW12 1300DNA,共转化感受态E.coli DH5a,筛选出3个白色阳性克隆,序列分析发现该标记DNA为1291bp。这一标记DNA序列的阐明为进一分析产毒遗传机理提供了新的信息。  相似文献   

7.
Next-generation sequencing of environmental samples can be challenging because of the variable DNA quantity and quality in these samples. High quality DNA libraries are needed for optimal results from next-generation sequencing. Environmental samples such as water may have low quality and quantities of DNA as well as contaminants that co-precipitate with DNA. The mechanical and enzymatic processes involved in extraction and library preparation may further damage the DNA. Gel size selection enables purification and recovery of DNA fragments of a defined size for sequencing applications. Nevertheless, this task is one of the most time-consuming steps in the DNA library preparation workflow. The protocol described here enables complete automation of agarose gel loading, electrophoretic analysis, and recovery of targeted DNA fragments. In this study, we describe a high-throughput approach to prepare high quality DNA libraries from freshwater samples that can be applied also to other environmental samples. We used an indirect approach to concentrate bacterial cells from environmental freshwater samples; DNA was extracted using a commercially available DNA extraction kit, and DNA libraries were prepared using a commercial transposon-based protocol. DNA fragments of 500 to 800 bp were gel size selected using Ranger Technology, an automated electrophoresis workstation. Sequencing of the size-selected DNA libraries demonstrated significant improvements to read length and quality of the sequencing reads.  相似文献   

8.
We are investigating approaches to increase DNA sequencing quality. Since a majorfactor in sequence generation is the cost of reagents and sample preparations, we have developed and optimized methods to sequence directly plasmid DNA isolated from alkaline lysis preparations. These methods remove the costly PCR and post-sequencing purification steps but can result in low sequence quality when using standard resuspension protocols on some sequencing platforms. This work outlines a simple, robust, and inexpensive resuspension protocol for DNA sequencing to correct this shortcoming. Resuspending the sequenced products in agarose before electrophoresis results in a substantial and reproducible increase in sequence quality and read length over resuspension in deionized water and has allowed us to use the aforementioned sample preparation methods to cut considerably the overall sequencing costs without sacrificing sequence quality. We demonstrate that resuspension of unpurified sequence products generated from template DNA isolated by a modified alkaline lysis technique in low concentrations of agarose yields a 384% improvement in sequence quality compared to resuspension in deionized water. Utilizing this protocol, we have produced more than 74,000 high-quality, long-read-length sequences from plasmid DNA template on the MegaBACET 1000 platform.  相似文献   

9.
Mass-spectrometry DNA sequencing   总被引:1,自引:0,他引:1  
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been explored widely for DNA sequencing. Compared to gel electrophoresis based sequencing systems, mass spectrometry produces very high resolution of sequencing fragments, rapid separation on microsecond time scales, and completely eliminates compressions associated with gel-based systems. While most of the research efforts have focused on using mass spectrometers to analyze the DNA products from Sanger sequencing or enzymatic digestion reactions, the read lengths attainable are currently insufficient for large-scale de novo sequencing. The advantage of mass-spectrometry sequencing is that one can unambiguously identify frameshift mutations and heterozygous mutations making it an ideal choice for resequencing projects. In these applications, DNA sequencing fragments that are the same length but with different base compositions are generated, which are challenging to consistently distinguish in gel-based sequencing systems. In contrast, MALDI-TOF MS produces mass spectra of these DNA sequencing fragments with nearly digital resolution, allowing accurate determination of the mixed bases. For these reasons mass spectrometry based sequencing has mainly been focused on the detection of frameshift mutations and single nucleotide polymorphisms (SNPs). More recently, assays have been developed to indirectly sequence DNA by first converting it into RNA. These assays take advantage of the increased resolution and detection ability of MALDI-TOF MS for RNA.  相似文献   

10.
目的:建立甲基营养菌MP681基因组文库,用于鸟枪法测序。方法:提取MP681基因组DNA,经超声随机片段化及T4 DNA聚合酶末端修平处理后,与经SmaⅠ酶切、小牛肠碱性磷酸酶(CIP)去磷酸化处理的pUC19载体连接,电击转化大肠杆菌DH5α感受态,并通过末端双向测序对文库质量进行评价。结果:分别构建了2~4 kb和4~6 kb基因组文库,电泳结果显示插入片段长度与预期符合,文库库容均在10万以上。结论:构建了插入片段大小和库容符合要求的甲基营养菌MP681全基因组鸟枪法2~4 kb、4~6 kb测序文库。  相似文献   

11.
发展中的DNA测序技术赵晓娟刘金毅综述蔡有余琦祖和*审校(中国医学科学院中国协和医科大学实验动物研究所北京)DNA序列分析是基因工程和分子生物学领域最重要的技术之一,是了解基因结构和功能的基础。“人类基因组计划”(humangenomeproject)的实施,有力地推动了高速DNA测序技术的发展。除经典的测序方法在技术环节上的不断改进外,近年来发展了一些全新的DNA测序方法,如毛细管凝胶电泳...  相似文献   

12.
DNA sequencing with direct blotting electrophoresis.   总被引:10,自引:0,他引:10       下载免费PDF全文
S Beck  F M Pohl 《The EMBO journal》1984,3(12):2905-2909
A method for transferring the DNA molecules of sequencing reaction mixtures onto an immobilizing matrix during electrophoresis has been developed. A blotting membrane moves with constant speed across the end of a very short, denaturing gel and collects the molecules according to size. A constant distance between bands for molecules differing in length by one nucleotide is obtained over a large range (approximately 600 nucleotides with a 5% gel), simplifying the determination of DNA sequences considerably. Reliable sequences of 500 nucleotides can be read and sequence features up to greater than 1000 nucleotides are revealed in a single experiment. The sequencing of a potential Z-DNA-forming fragment from Escherichia coli DNA is given as an example and possible further developments are discussed.  相似文献   

13.
Xu Y  Bruch RC  Soper SA 《BioTechniques》2000,28(5):904-8, 910, 912
Solid-phase micro-reactors have been prepared in glass capillaries for DNA sequencing applications using slab gel electrophoresis, which consisted of a fused silica capillary (i.d. = 100 microns; o.d. = 365 microns; length = 15 cm; volume = 1.2 microL) that contained a covalently bound biotin molecule. With the addition of streptavidin to the capillary, an anchoring site was produced for the tethering of biotinylated DNA sequencing templates to the wall of the capillary. Using a four-lane, single dye primer chemistry sequencing strategy, the individual tracts were prepared in the capillaries using cycle sequencing (20 thermal cycles) on a PCR-generated lambda-bacteriophage template (about 1000 bp). The dye label in this case was a fluorescent tag that displayed emission properties in the near-IR and could be processed on an automated sequencer. The read length was found to be 589 bases, which was determined primarily by the fractionating power of the gel. It was also found that the tethering system was very stable to typical cycle sequencing conditions, with the amount of tethered DNA lost amounting to 40% after 120 thermal cycles. The ability to use dye terminator chemistry was also investigated by using a near-IR dye-labeled terminator (ddGTP). It was found that the quality of the ladder that was generated was comparable to that obtained in a conventional sample preparation format. However, ethanol precipitation was required before gel loading to remove excess terminator.  相似文献   

14.
An integrated system with a nano-reactor for cycle-sequencing reaction coupled to on-line purification and capillary gel electrophoresis has been demonstrated. Fifty nanoliters of reagent solution, which includes dye-labeled terminators, polymerase, BSA and template, was aspirated and mixed with the template inside the nano-reactor followed by cycle-sequencing reaction. The reaction products were then purified by a size-exclusion chromatographic column operated at 50°C followed by room temperature on-line injection of the DNA fragments into a capillary for gel electrophoresis. Over 450 bases of DNA can be separated and identified. As little as 25 nl reagent solution can be used for the cycle-sequencing reaction with a slightly shorter read length. Significant savings on reagent cost is achieved because the remaining stock solution can be reused without contamination. The steps of cycle sequencing, on-line purification, injection, DNA separation, capillary regeneration, gel-filling and fluidic manipulation were performed with complete automation. This system can be readily multiplexed for high-throughput DNA sequencing or PCR analysis directly from templates or even biological materials.  相似文献   

15.
A method is described that allows the sequencing of polymerase chain reaction (PCR) products containing CACA repeats. The method was tested using a DNA polymorphism that exists at the 3' end of the dystrophin gene. This polymorphism consists of a variation in the length of a CACA dinucleotide repeat. Four alleles from a total of 16 individuals were sequenced at this locus after the DNA sequence had been amplified by the PCR. Five examples of each of the common alleles were sequenced. For each allele all five sequences were the same. The only example of a rare allele was also sequenced. The PCR products of DNA sequences containing dinucleotide repeats consist of a number of bands differing by 2 bp below the most intense main band. Previously, direct sequencing of the PCR products lead to ambiguities and smearing at and above the CACA repeat. In this paper, the main PCR band was cut out of a sequencing gel and directly sequenced to give a clear DNA sequence. Our results indicate that for a particular allele, all individuals had exactly the same DNA sequence. This implies that with the appropriate choice of oligonucleotide primers, polymorphisms could be detected without electrophoresis.  相似文献   

16.
Optimal reconstruction of a sequence from its probes.   总被引:4,自引:0,他引:4  
An important combinatorial problem, motivated by DNA sequencing in molecular biology, is the reconstruction of a sequence over a small finite alphabet from the collection of its probes (the sequence spectrum), obtained by sliding a fixed sampling pattern over the sequence. Such construction is required for Sequencing-by-Hybridization (SBH), a novel DNA sequencing technique based on an array (SBH chip) of short nucleotide sequences (probes). Once the sequence spectrum is biochemically obtained, a combinatorial method is used to reconstruct the DNA sequence from its spectrum. Since technology limits the number of probes on the SBH chip, a challenging combinatorial question is the design of a smallest set of probes that can sequence an arbitrary DNA string of a given length. We present in this work a novel probe design, crucially based on the use of universal bases [bases that bind to any nucleotide (Loakes and Brown, 1994)] that drastically improves the performance of the SBH process and asymptotically approaches the information-theoretic bound up to a constant factor. Furthermore, the sequencing algorithm we propose is substantially simpler than the Eulerian path method used in previous solutions of this problem.  相似文献   

17.
Modern genetic analyses rely on efficient genotyping of single-nucleotide polymorphisms (SNP) or insertion/deletion length polymorphisms (InDel) in genomes. Methods available to genotype these polymorphisms include sequencing, cleaved amplified polymorphic sequence, high-resolution DNA melting, and microarray analyses, which are all rather tedious or expensive to set up for daily use. Here, we report a simplified label-free CELI endonuclease (CELI)-based protocol that enables us to detect both SNPs and InDels for fragment lengths between 500 and 6 kb. PCR-amplified target DNA fragments were annealed, cleaved by CELI, and analyzed either cost-effectively by agarose gel electrophoresis or automatically by capillary electrophoresis. The optimal amplification sizes, potential blind ends, and the maximum pooling capacities were examined for both electrophoresis protocols. We believe that the CELI-based genotyping protocol can be used in the detection of mutations, marker-assisted breeding, map-based cloning, and genome-wide association studies.  相似文献   

18.
We report a capillary-based DNA sequencing read length of 100 bases in 16 min using end-labeled free-solution conjugate electrophoresis (FSCE) with a monodisperse poly-N-substituted glycine (polypeptoid) as a synthetic drag-tag. FSCE enabled rapid separation of single-stranded (ss) DNA sequencing fragments with single-base resolution without the need for a viscous DNA separation matrix. Protein-based drag-tags previously used for FSCE sequencing, for example, streptavidin, are heterogeneous in molar mass (polydisperse); the resultant band-broadening can make it difficult to obtain the single-base resolution necessary for DNA sequencing. In this study, we synthesized and HPLC-purified a 70mer poly-N-(methoxyethyl)glycine (NMEG) drag-tag with a molar mass of - 11 kDa. The NMEG monomers that comprise this peptoid drag-tag are interesting for bioanalytical applications, because the methoxyethyl side chain's chemical structure is reminiscent of the basic monomer unit of polyethylene glycol, a highly biocompatible commercially available polymer, which, however, is not available in monodisperse preparation at an - 11 kDa molar mass. This is the first report of ssDNA separation and of four-color, base-by-base DNA sequencing by FSCE through the use of a chemically synthesized drag-tag. These results show that high-molar mass, chemically synthesized drag-tags based on the polyNMEG structure, if obtained in monodisperse preparation, would serve as ideal drag-tags and could help FSCE reach the commercially relevant read lengths of 100 bases or more.  相似文献   

19.
Macrostructure of the tomato telomeres.   总被引:23,自引:3,他引:20  
The macrostructure of the tomato telomeres has been investigated by in situ hybridization, genomic sequencing, and pulsed-field gel electrophoresis. In situ hybridizations with a cloned telomeric sequence from Arabidopsis thaliana indicated that the telomeric repeat of tomato cross-hybridizes with that of Arabidopsis and is located at all telomeres. Bal31 digestion kinetics confirmed that the tomato telomeric repeat represents the outermost DNA sequence of each tomato chromosome. Genomic sequencing of enriched tomato telomeric sequences, using primers derived from the Arabidopsis sequence, revealed that the consensus sequence of the tomato telomeric repeat is TT(T/A)AGGG compared with the Arabidopsis consensus sequence of TTTAGGG. Furthermore, as shown by pulsed-field gel electrophoresis, the telomeric repeat of tomato is separated by not more than a few hundred kilobases from a previously described 162-base pair satellite DNA repeat of tomato (TGR I) at 20 of the 24 telomeres. Together, these sequences are found in the heterochromatic terminal knob observed in pachytene chromosomes. Therefore, these two repeats determine the structure of 20 of the 24 tomato chromosome ends over approximately 2% of the total chromosome length.  相似文献   

20.
D Chen  H R Harke    N J Dovichi 《Nucleic acids research》1992,20(18):4873-4880
We report a modification to the peak-height encoded DNA sequencing technique of Tabor and Richardson. As in the original protocol, the sequencing reaction uses modified T7 polymerase with manganese rather than magnesium to produce very uniform incorporation of each dideoxynucleoside. To improve sequencing accuracy, two fluorescently labeled primers are employed in separate sequencing reactions. As an example, one sequencing reaction uses a FAM-labeled primer with dideoxyadenosine triphosphate and dideoxycytosine triphosphate; the concentrations of ddATP and ddCTP are adjusted to produce a 2:1 variation in the relative intensity of fragments. The second sequencing reaction uses a TAMRA labeled primer with dideoxythymidine triphosphate and dideoxyguanidine triphosphate; the concentrations of ddTTP and ddGTP are adjusted to produce a 2:1 variation in relative intensity of fragments. The pooled reaction products are separated by capillary gel electrophoresis and identified by one of three different detector systems. Use of a 2:1 peak height ratio typically produces a sequencing accuracy of 97.5% for the first 350 bases; a 3:1 peak height ratio improves accuracy to 99.5% for the first 400 bases. For these experiments, capillary electrophoresis is performed at an electric field of 200 V/cm; two to three hours are required to separate sequencing fragments up to 400 nucleotides in length.  相似文献   