首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
MOTIVATION: Comparing tandem mass spectra (MSMS) against a known dataset of protein sequences is a common method for identifying unknown proteins; however, the processing of MSMS by current software often limits certain applications, including comprehensive coverage of post-translational modifications, non-specific searches and real-time searches to allow result-dependent instrument control. This problem deserves attention as new mass spectrometers provide the ability for higher throughput and as known protein datasets rapidly grow in size. New software algorithms need to be devised in order to address the performance issues of conventional MSMS protein dataset-based protein identification. METHODS: This paper describes a novel algorithm based on converting a collection of monoisotopic, centroided spectra to a new data structure, named 'peptide finite state machine' (PFSM), which may be used to rapidly search a known dataset of protein sequences, regardless of the number of spectra searched or the number of potential modifications examined. The algorithm is verified using a set of commercially available tryptic digest protein standards analyzed using an ABI 4700 MALDI TOFTOF mass spectrometer, and a free, open source PFSM implementation. It is illustrated that a PFSM can accurately search large collections of spectra against large datasets of protein sequences (e.g. NCBI nr) using a regular desktop PC; however, this paper only details the method for identifying peptide and subsequently protein candidates from a dataset of known protein sequences. The concept of using a PFSM as a peptide pre-screening technique for MSMS-based search engines is validated by using PFSM with Mascot and XTandem. AVAILABILITY: Complete source code, documentation and examples for the reference PFSM implementation are freely available at the Proteome Commons, http://www.proteomecommons.org and source code may be used both commercially and non-commercially as long as the original authors are credited for their work.  相似文献   

2.
Chemical cross-linking combined with mass spectrometry provides a powerful method for identifying protein-protein interactions and probing the structure of protein complexes. A number of strategies have been reported that take advantage of the high sensitivity and high resolution of modern mass spectrometers. Approaches typically include synthesis of novel cross-linking compounds, and/or isotopic labeling of the cross-linking reagent and/or protein, and label-free methods. We report Xlink-Identifier, a comprehensive data analysis platform that has been developed to support label-free analyses. It can identify interpeptide, intrapeptide, and deadend cross-links as well as underivatized peptides. The software streamlines data preprocessing, peptide scoring, and visualization and provides an overall data analysis strategy for studying protein-protein interactions and protein structure using mass spectrometry. The software has been evaluated using a custom synthesized cross-linking reagent that features an enrichment tag. Xlink-Identifier offers the potential to perform large-scale identifications of protein-protein interactions using tandem mass spectrometry.  相似文献   

3.
Whole-cell protein quantification using MS has proven to be a challenging task. Detection efficiency varies significantly from peptide to peptide, molecular identities are not evident a priori, and peptides are dispersed unevenly throughout the multidimensional data space. To overcome these challenges we developed an open-source software package, MapQuant, to quantify comprehensively organic species detected in large MS datasets. MapQuant treats an LC/MS experiment as an image and utilizes standard image processing techniques to perform noise filtering, watershed segmentation, peak finding, peak fitting, peak clustering, charge-state determination and carbon-content estimation. MapQuant reports abundance values that respond linearly with the amount of sample analyzed on both low- and high-resolution instruments (over a 1000-fold dynamic range). Background noise added to a sample, either as a medium-complexity peptide mixture or as a high-complexity trypsinized proteome, exerts negligible effects on the abundance values reported by MapQuant and with coefficients of variance comparable to other methods. Finally, MapQuant's ability to define accurate mass and retention time features of isotopic clusters on a high-resolution mass spectrometer can increase protein sequence coverage by assigning sequence identities to observed isotopic clusters without corresponding MS/MS data.  相似文献   

4.
Although generating large amounts of proteomic data using tandem mass spectrometry has become routine, there is currently no single set of comprehensive tools for the rigorous analysis of tandem mass spectrometry results given the large variety of possible experimental aims. Currently available applications are typically designed for displaying proteins and posttranslational modifications from the point of view of the mass spectrometrist and are not versatile enough to allow investigators to develop biological models of protein function, protein structure, or cell state. In addition, storage and dissemination of mass spectrometry-based proteomic data are problems facing the scientific community. To address these issues, we have developed a relational database model that efficiently stores and manages large amounts of tandem mass spectrometry results. We have developed an integrated suite of multifunctional analysis software for interpreting, comparing, and displaying these results. Our system, Bioinformatic Graphical Comparative Analysis Tools (BIGCAT), allows sophisticated analysis of tandem mass spectrometry results in a biologically intuitive format and provides a solution to many data storage and dissemination issues.  相似文献   

5.
Using the definitions of protein folds encoded in a text string, a dynamic programming algorithm was devised to compare these and identify their largest common substructure and calculate the distance (in terms of the number of edit operations) that this lay from each structure. This provided a metric on which the folds were clustered into a 'phylogenetic' tree. This construction differs from previous automatic structure clustering algorithms as it has explicit representation of the structures at 'ancestral' branching nodes, even when these have no corresponding known structure. The resulting tree was compared with that compiled by an 'expert' in the field and while there was broad agreement, differences were found that resulted from differing degrees of emphasis being placed on the types of operations that can be used to transform structures. Some concluding speculations on the relationship of such trees to the evolutionary history and folding of the proteins are advanced.  相似文献   

6.
New mass spectrometry techniques, such as electrospray ionization (ESI), allow the study of large biomolecules and peptide mixtures. The data produced are complex and interpretation can be a long and tedious process. A new suite of data-processing software is described which allows many of these operations to be carried out in a rapid, automated way. Software is described for the deconvolution of the spectra of multiply charged ions, for both pure compounds and mixtures. The rapid peptide mapping of protein digests from h.p.l.c.-m.s. data and peptide sequence confirmation from multiple-stage (MS)-m.s. data using tandem quadrupole m.s. are also described. In addition preliminary results are presented on first principle sequencing of unknown peptides from MS-m.s. experiments.  相似文献   

7.
Peptide identification via tandem mass spectrometry sequence database searching is a key method in the array of tools available to the proteomics researcher. The ability to rapidly and sensitively acquire tandem mass spectrometry data and perform peptide and protein identifications has become a commonly used proteomics analysis technique because of advances in both instrumentation and software. Although many different tandem mass spectrometry database search tools are currently available from both academic and commercial sources, these algorithms share similar core elements while maintaining distinctive features. This review revisits the mechanism of sequence database searching and discusses how various parameter settings impact the underlying search.  相似文献   

8.
9.
The iTRAQ labeling method combined with shotgun proteomic techniques represents a new dimension in multiplexed quantitation for relative protein expression measurement in different cell states. To expedite the analysis of vast amounts of spectral data, we present a fully automated software package, called Multi-Q, for multiplexed iTRAQ-based quantitation in protein profiling. Multi-Q is designed as a generic platform that can accommodate various input data formats from search engines and mass spectrometer manufacturers. To calculate peptide ratios, the software automatically processes iTRAQ's signature peaks, including peak detection, background subtraction, isotope correction, and normalization to remove systematic errors. Furthermore, Multi-Q allows users to define their own data-filtering thresholds based on semiempirical values or statistical models so that the computed results of fold changes in peptide ratios are statistically significant. This feature facilitates the use of Multi-Q with various instrument types with different dynamic ranges, which is an important aspect of iTRAQ analysis. The performance of Multi-Q is evaluated with a mixture of 10 standard proteins and human Jurkat T cells. The results are consistent with expected protein ratios and thus demonstrate the high accuracy, full automation, and high-throughput capability of Multi-Q as a large-scale quantitation proteomics tool. These features allow rapid interpretation of output from large proteomic datasets without the need for manual validation. Executable Multi-Q files are available on Windows platform at http://ms.iis.sinica.edu.tw/Multi-Q/.  相似文献   

10.

Background

In a single proteomic project, tandem mass spectrometers can produce hundreds of millions of tandem mass spectra. However, majority of tandem mass spectra are of poor quality, it wastes time to search them for peptides. Therefore, the quality assessment (before database search) is very useful in the pipeline of protein identification via tandem mass spectra, especially on the reduction of searching time and the decrease of false identifications. Most existing methods for quality assessment are supervised machine learning methods based on a number of features which describe the quality of tandem mass spectra. These methods need the training datasets with knowing the quality of all spectra, which are usually unavailable for the new datasets.

Results

This study proposes an unsupervised machine learning method for quality assessment of tandem mass spectra without any training dataset. This proposed method estimates the conditional probabilities of spectra being high quality from the quality assessments based on individual features. The probabilities are estimated through a constraint optimization problem. An efficient algorithm is developed to solve the constraint optimization problem and is proved to be convergent. Experimental results on two datasets illustrate that if we search only tandem spectra with the high quality determined by the proposed method, we can save about 56 % and 62% of database searching time while losing only a small amount of high-quality spectra.

Conclusions

Results indicate that the proposed method has a good performance for the quality assessment of tandem mass spectra and the way we estimate the conditional probabilities is effective.
  相似文献   

11.
Increasing numbers of large proteomic datasets are becoming available. As attempts are made to interpret these datasets and integrate them with other forms of genomic data, researchers are becoming more aware of the importance of data quality with respect to protein identification. We present three simple and universal metrics that describe different aspects of the quality of protein identifications by peptide mass fingerprinting. Hit ratio gives an indication of the signal-to-noise ratio in a mass spectrum, mass coverage measures the amount of protein sequence matched, and excess of limit-digested peptides reflects the completeness of the digestion that precedes the peptide mass fingerprinting. Receiver-operating characteristic plots show that the novel metric, excess of limit-digested peptides, can discriminate between correct and random matches more accurately than search score when validating the results from a state-of-the-art protein identification software system (Mascot) especially when combined with the two other metrics, hit ratio and mass coverage. Recommendations are made regarding the use of the metrics when reporting protein identification experiments.  相似文献   

12.

Background  

Hydrogen/deuterium exchange mass spectrometry (H/DX-MS) experiments implemented to characterize protein interaction and protein folding generate large quantities of data. Organizing, processing and visualizing data requires an automated solution, particularly when accommodating new tandem mass spectrometry modes for H/DX measurement. We sought to develop software that offers flexibility in defining workflows so as to support exploratory treatments of H/DX-MS data, with a particular focus on the analysis of very large protein systems and the mining of tandem mass spectrometry data.  相似文献   

13.
Relative and absolute intensity-based protein quantification across cell lines, tissue atlases and tumour datasets is increasingly available in public datasets. These atlases enable researchers to explore fundamental biological questions, such as protein existence, expression location, quantity and correlation with RNA expression. Most studies provide MS1 feature-based label-free quantitative (LFQ) datasets; however, growing numbers of isobaric tandem mass tags (TMT) datasets remain unexplored. Here, we compare traditional intensity-based absolute quantification (iBAQ) proteome abundance ranking to an analogous method using reporter ion proteome abundance ranking with data from an experiment where LFQ and TMT were measured on the same samples. This new TMT method substitutes reporter ion intensities for MS1 feature intensities in the iBAQ framework. Additionally, we compared LFQ-iBAQ values to TMT-iBAQ values from two independent large-scale tissue atlas datasets (one LFQ and one TMT) using robust bottom-up proteomic identification, normalisation and quantitation workflows.  相似文献   

14.
SUMMARY: The accurate mass and time (AMT) tag approach is used for analysis of large scale experiments by combining information generated over multiple datasets and instrument types. The VIPER software package is one of the key components of the data processing pipeline and implements automated algorithms to discover LC-MS features, align and match these LC-MS features to a database of peptides previously identified in LC-MS/MS analyses, and identify and quantify pairs of isotopically labeled peptides. AVAILABILITY: VIPER may be downloaded free of charge at http://ncrr.pnl.gov/software/  相似文献   

15.
MOTIVATION: Application of mass spectrometry in proteomics is a breakthrough in high-throughput analyses. Early applications have focused on protein expression profiles to differentiate among various types of tissue samples (e.g. normal versus tumor). Here our goal is to use mass spectra to differentiate bacterial species using whole-organism samples. The raw spectra are similar to spectra of tissue samples, raising some of the same statistical issues (e.g. non-uniform baselines and higher noise associated with higher baseline), but are substantially noisier. As a result, new preprocessing procedures are required before these spectra can be used for statistical classification. RESULTS: In this study, we introduce novel preprocessing steps that can be used with any mass spectra. These comprise a standardization step and a denoising step. The noise level for each spectrum is determined using only data from that spectrum. Only spectral features that exceed a threshold defined by the noise level are subsequently used for classification. Using this approach, we trained the Random Forest program to classify 240 mass spectra into four bacterial types. The method resulted in zero prediction errors in the training samples and in two test datasets having 240 and 300 spectra, respectively.  相似文献   

16.
MOTIVATION: In proteomics, reverse database searching is used to control the false match frequency for tandem mass spectrum/peptide sequence matches, but reversal creates sequences devoid of patterns that usually challenge database-search software. RESULTS: We designed an unsupervised pattern recognition algorithm for detecting patterns with various lengths from large sequence datasets. The patterns found in a protein sequence database were used to create decoy databases using a Monte Carlo sampling algorithm. Searching these decoy databases led to the prediction of false positive rates for spectrum/peptide sequence matches. We show examples where this method, independent of instrumentation, database-search software and samples, provides better estimation of false positive identification rates than a prevailing reverse database searching method. The pattern detection algorithm can also be used to analyze sequences for other purposes in biology or cryptology. AVAILABILITY: On request from the authors. SUPPLEMENTARY INFORMATION: http://bioinformatics.psb.ugent.be/.  相似文献   

17.
Lipid rafts were prepared according to standard protocols from Jurkat T cells stimulated via T cell receptor/CD28 cross-linking and from control (unstimulated) cells. Co-isolating proteins from the control and stimulated cell preparations were labeled with isotopically normal (d0) and heavy (d8) versions of the same isotope-coded affinity tag (ICAT) reagent, respectively. Samples were combined, proteolyzed, and resultant peptides fractionated via cation exchange chromatography. Cysteine-containing (ICAT-labeled) peptides were recovered via the biotin tag component of the ICAT reagents by avidin-affinity chromatography. On-line micro-capillary liquid chromatography tandem mass spectrometry was performed on both avidin-affinity (ICAT-labeled) and flow-through (unlabeled) fractions. Initial peptide sequence identification was by searching recorded tandem mass spectrometry spectra against a human sequence data base using SEQUEST software. New statistical data modeling algorithms were then applied to the SEQUEST search results. These allowed for discrimination between likely "correct" and "incorrect" peptide assignments, and from these the inferred proteins that they collectively represented, by calculating estimated probabilities that each peptide assignment and subsequent protein identification was a member of the "correct" population. For convenience, the resultant lists of peptide sequences assigned and the proteins to which they corresponded were filtered at an arbitrarily set cut-off of 0.5 (i.e. 50% likely to be "correct") and above and compiled into two separate datasets. In total, these data sets contained 7667 individual peptide identifications, which represented 2669 unique peptide sequences, corresponding to 685 proteins and related protein groups.  相似文献   

18.
Computational approaches for predicting protein-protein interfaces are extremely useful for understanding and modelling the quaternary structure of protein assemblies. In particular, partner-specific binding site prediction methods allow delineating the specific residues that compose the interface of protein complexes. In recent years, new machine learning and other algorithmic approaches have been proposed to solve this problem. However, little effort has been made in finding better training datasets to improve the performance of these methods. With the aim of vindicating the importance of the training set compilation procedure, in this work we present BIPSPI+, a new version of our original server trained on carefully curated datasets that outperforms our original predictor. We show how prediction performance can be improved by selecting specific datasets that better describe particular types of protein interactions and interfaces (e.g. homo/hetero). In addition, our upgraded web server offers a new set of functionalities such as the sequence-structure prediction mode, hetero- or homo-complex specialization and the guided docking tool that allows to compute 3D quaternary structure poses using the predicted interfaces. BIPSPI+ is freely available at https://bipspi.cnb.csic.es.  相似文献   

19.
BACKGROUND: HDX mass spectrometry is a powerful platform to probe protein structure dynamics during ligand binding, protein folding, enzyme catalysis, and such. HDX mass spectrometry analysis derives the protein structure dynamics based on the mass increase of a protein of which the backbone protons exchanged with solvent deuterium. Coupled with enzyme digestion and MS/MS analysis, HDX mass spectrometry can be used to study the regional dynamics of protein based on the m/z value or percentage of deuterium incorporation for the digested peptides in the HDX experiments. Various software packages have been developed to analyze HDX mass spectrometry data. Despite the progresses, proper and explicit statistical treatment is still lacking in most of the current HDX mass spectrometry software. In order to address this issue, we have developed the HDXanalyzer for the statistical analysis of HDX mass spectrometry data using R, Python, and RPY2. IMPLEMENTATION AND RESULTS: HDXanalyzer package contains three major modules, the data processing module, the statistical analysis module, and the user interface. RPY2 is employed to enable the connection of these three components, where the data processing module is implemented using Python and the statistical analysis module is implemented with R. RPY2 creates a low-level interface for R and allows the effective integration of statistical module for data processing. The data processing module generates the centroid for the peptides in form of m/z value, and the differences of centroids between the peptides derived from apo and ligand-bound protein allow us to evaluate whether the regions have significant changes in structure dynamics or not. Another option of the software is to calculate the deuterium incorporation rate for the comparison. The two types of statistical analyses are Paired Student's t-test and the linear combination of the intercept for multiple regression and ANCOVA model. The user interface is implemented with wxpython to facilitate the data visualization in graphs and the statistical analysis output presentation. In order to evaluate the software, a previously published xylanase HDX mass spectrometry analysis dataset is processed and presented. The results from the different statistical analysis methods are compared and shown to be similar. The statistical analysis results are overlaid with the three dimensional structure of the protein to highlight the regional structure dynamics changes in the xylanase enzyme. CONCLUSION: Statistical analysis provides crucial evaluation of whether a protein region is significantly protected or unprotected during the HDX mass spectrometry studies. Although there are several other available software programs to process HDX experimental data, HDXanalyzer is the first software program to offer multiple statistical methods to evaluate the changes in protein structure dynamics based on HDX mass spectrometry analysis. Moreover, the statistical analysis can be carried out for both m/z value and deuterium incorporation rate. In addition, the software package can be used for the data generated from a wide range of mass spectrometry instruments.  相似文献   

20.
Protein and peptide mass analysis and amino acid sequencing by mass spectrometry is widely used for identification and annotation of post-translational modifications (PTMs) in proteins. Modification-specific mass increments, neutral losses or diagnostic fragment ions in peptide mass spectra provide direct evidence for the presence of post-translational modifications, such as phosphorylation, acetylation, methylation or glycosylation. However, the commonly used database search engines are not always practical for exhaustive searches for multiple modifications and concomitant missed proteolytic cleavage sites in large-scale proteomic datasets, since the search space is dramatically expanded. We present a formal definition of the problem of searching databases with tandem mass spectra of peptides that are partially (sub-stoichiometrically) modified. In addition, an improved search algorithm and peptide scoring scheme that includes modification specific ion information from MS/MS spectra was implemented and tested using the Virtual Expert Mass Spectrometrist (VEMS) software. A set of 2825 peptide MS/MS spectra were searched with 16 variable modifications and 6 missed cleavages. The scoring scheme returned a large set of post-translationally modified peptides including precise information on modification type and position. The scoring scheme was able to extract and distinguish the near-isobaric modifications of trimethylation and acetylation of lysine residues based on the presence and absence of diagnostic neutral losses and immonium ions. In addition, the VEMS software contains a range of new features for analysis of mass spectrometry data obtained in large-scale proteomic experiments. Windows binaries are available at http://www.yass.sdu.dk/.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号