1.
A nonparametric probability estimator, having a uniform kernel, is utilized to obtain the joint probability density function of BOD and DO along the stretch of a stream when the velocity is distance dependent. The stochastic model is used to obtain probabilistic confidence bounds for BOD and DO. An example and computations are presented which illustrate the usefulness of the model.  相似文献   

2.
A practical method for predicting the dissolved oxygen (DO) profile in a stream receiving biodegradable waste is presented. In this method the BOD (accumulated O2 uptake) curve is obtained using an open jug technique. The accumulated O2 uptake curve thus developed is employed in numerical integration with the physical reaeration data for the receiving stream to predict the DO profile in the stream. In the present study, the method was examined using 10-liter open jar reactors to obtain the O2 uptake curves, and the receiving stream was a 670-liter simulated stream apparatus which has been employed in previous studies on stream reaeration. The method was found to provide a fairly good prediction of the actual dissolved oxygen profile observed in the receiving stream. The effect of the reaeration constant, K2 )agitation effect(, on the kinetics of O2 uptake was also investigated and it was found that increased agitation (higher K2 value) caused some increase in the accumulated oxygen uptake (BOD) curve with most of the increase coming after the so-called “plateau” area in the O2 uptake curve, i.e., in the general case, after the low point along the DO sag curve.  相似文献   

3.
Microenvironmental studies regarding plant oxygen release in a wastewater environment are important to understand the principles of constructed wetlands for wastewater treatment. pH, oxidation reduction potential (ORP), and dissolved oxygen (DO) microprofiles for the lateral and main roots of the bulrush (Scirpus validus) in a vertical flow constructed wetland fed with municipal wastewater were measured using microelectrode techniques. pH was found to be low (6.91-6.98) near the lateral root surface, indicating possible nitrification or H(+) extrusion. The ORP at the lateral root surface was between +250 and +317 mV and gradually reached the bulk solution ORP (+14 to -54 mV) at a radial distance of approximately 4,750 microm. DO values at the lateral root surface varied from 0.64-2.04 mg L(-1) as bulk biochemical oxygen demand (BOD) changed from 24 to 1,267 mg L(-1). DO at the lateral root surface and the thickness of the oxygen layer around the root marginally increased with an increase in bulk BOD, while ORP at the lateral and main root surface decreased. pH and DO values did not change near the main root and had the bulk solution values. The results of this study provide insights into root-induced microenvironments and would be helpful for the quantification of the total amount of oxygen contributed by plants in constructed wetlands.  相似文献   

4.
The biochemical oxygen demand (BOD) determination was studied using a novel flow injection analysis (FIA) system with encapsulated Saccharomyces cerevisiae cells and an oxygen electrode and was compared with conventional 5-day BOD tests. S. cerevisiae cells were packed in a calcium alginate capsule at a dry cell weight of 250 g/l of capsule core. The level of dissolved oxygen (DO) was reduced due to the enhanced respiratory activity of the microbial cells when the injected nutrient passed through the bioreactor. The decrease in DO (ΔDO) was intensified with the amount of microbial cells packed in the bioreactor. However, the specific ΔDO decreased as the amount of cells loaded in the bioreactor increased. The ΔDO value was dependent on the pH and temperature of the mobile phase and reached its maximum value at 35°C and pH 7–8. Also, ΔDO became larger at longer response times as the flow rate of the mobile phase decreased. The measurement of ΔDO was repeated more than six times consecutively using a 20-ppm standard glucose and glutamic acid solution, which confirmed the reproducibility with a standard deviation of 0.95%. A strong linear correlation between ΔDO and BOD was also observed. The 5-day BOD values of actual water and wastewater samples were in accordance with the BOD values obtained by this FIA method using encapsulated S. cerevisiae cells. Unlike the cell-immobilized bead system, there was no contamination of the bioreactor resulting from any leak of yeast cells from the sensor capsules during BOD measurements.  相似文献   

5.
The performance of an activated sludge wastewater treatment process consisting of an aeration tank and a secondary settler has been studied. A tanks-in-series model with backflow was used for mathematical modeling of the activated sludge wastewater treatment process. Non-linear algebraic equations obtained from the material balances of MLSS (mixed liquor suspended solids or activated sludge), BOD (biological oxygen demand) and DO (dissolved oxygen) for the aeration tank and the settler and from the behavior of the settler were solved simultaneously using the modified Newton-Raphson technique. The concentration profiles of MLSS, BOD and DO in the aeration tank were obtained. The simulation results were examined from the viewpoints of mixing in the aeration tank and flow in the secondary settling tank. The relationships between the overall performance of the activated sludge process and the operating and design parameters such as hydraulic residence time, influent BOD, recycle ratio and waste sludge ratio were obtained.  相似文献   

6.
A biochemical oxygen demand (BOD) sensor has been developed, which is based on an immobilized mixed culture of microorganisms combined with a dissolved oxygen (DO) optical fiber. The sensing film for BOD measurement consists of an organically-modified silicate (ORMOSIL) film embedded with tri(4,7-diphenyl-1,10-phenanthroline) ruthenium(II) perchlorate and three kinds of seawater microorganisms immobilized on a polyvinyl alcohol sol-gel matrix. The BOD measurements were carried out in the kinetic mode inside a light-proof cell and with constant temperature. Measurements were taken for 3 min followed by 10 min recovery time in 10 mg/L glucose/glutamate (GGA) BOD standard solution, and the range of determination was from 0.2 to 40 mg/L GGA. The effects of temperature, pH and sodium chloride concentration on the BOD sensing films were studied. BOD values estimated by this optical BOD sensing film correlate well with those determined by the conventional BOD5 method for seawater samples.  相似文献   

7.
层次分析法对南水北调中线水源区的水质评价   总被引:16,自引:0,他引:16  
层次分析法(AHP)是一种多指标多因素综合评价法,其理论内容深刻而表现形式简单,包括递阶层次结构模型、判断矩阵的建立及其求值、一致性检验和综合指数计算等运算过程.在南水北调中线水源区3个采样点进行了2a的水体浮游植物和9项理化指标的检测,并应用层次分析法通过季节4因素和6项理化指标对水质进行综合评价.结果表明:层次分析综合指数PI在3采样点有差异并且变化灵敏,渠首 (陶岔S1 ) PI=0.5697,水质属于污染;库心 (小太平洋S2 ) PI=0.3619,水质属于尚清洁;丹江入库上游 (大石桥S3 ), PI=0.7755,水质属于中污染;AHP分析结果与实际基本相符.根据结果分析认为:层次分析法做为综合评价法对水质评价有重要性,值得推广应用;丹江口水库是重要的水资源,但目前水质状况并不理想,因此做好水源区的长期生态监测,加强理论和技术研究,改善水质,极为重要.  相似文献   

8.
生物传感器快速测定BOD的研究   总被引:13,自引:0,他引:13  
生化需氧量(biochemicaloxygendemand,BOD)是一种表征水体有机污染程度的综合指标,广泛应用于水体监测和废水处理厂的运行控制。由于BOD的标准测定方法需时5天,不能及时地反映水质状况和反馈处理信息,因此快速测定BOD的方法和仪器化研究近年来得到广泛的重视。利用生物传感器测定BOD是一种有效地快速测定废水中可生化降解有机物的方法。介绍生物传感器的工作原理及其生物敏感材料,讨论BOD传感器的性能参数以及BOD快速测定值(BODst)与标准BOD5值的一致性问题。对现阶段市场上常见的几种BOD快速测定仪进行简单的介绍,并对它们的性能进行比较 。  相似文献   

9.
The aim of this study was to investigate the treatment efficiency of passive vertical-flow wetland filters containing different macrophytes (Phragmites and/or Typha) and granular media with different adsorption capacities. Gravel, sand, granular activated carbon, charcoal and Filtralite (light expanded clay) were used as filter media. Different concentrations of lead and copper sulfate were added to polluted urban stream inflow water to simulate pretreated mine wastewater. The relationships between growth media, microbial and plant communities as well as the reduction of predominantly lead, copper and five-day biochemical oxygen demand (BOD5) were investigated. An analysis of variance showed that concentration reductions (mg l(-1)) of lead, copper and BOD5 were significantly similar for the six experimental wetlands. Microbial diversity was low due to metal pollution and similar for all filters. There appears to be no additional benefit in using adsorption media and macrophytes to enhance biomass performance during the first 10 months of operation.  相似文献   

10.
A simple, efficient and cost-effective method for municipal wastewater treatment is examined in this paper. The municipal wastewater is treated using an upflow anaerobic sludge bed (UASB) reactor followed by flash aeration (FA) as the post-treatment, without implementing aerobic biological processes. The UASB reactor was operated without recycle, at hydraulic retention time (HRT) of 8 h and achieved consistent removal of BOD, COD and TSS of 60-70% for more than 12 months. The effect of FA on UASB effluent post-treatment was studied at different HRT (15, 30 and 60 min) and dissolved oxygen (DO) concentrations (low DO = 1-2 mg/L and high DO = 5-6 mg/L). The optimum conditions for BOD, COD and sulfide removal were 30-60 min HRT and high DO concentration inside the FA tank. The final effluent after clarification was characterized by BOD and COD values of 28-35 and 50-58 mg/L, respectively. Sulfides were removed by more than 80%, but the fecal coliform only by ~2 log. The UASB followed by FA is a simple and efficient process for municipal wastewater treatment, except for fecal coliform, enabling water and nutrients recycling to agriculture.  相似文献   

11.
A novel algorithm for predicting BOD(5) from the dissolved oxygen (DO) concentration after a relatively short incubation period is presented and evaluated experimentally. Test runs on synthetic and experimentally derived raw data suggest that BOD(5) can be predicted to within 15% ca. 36 h. The method can be improved by filtering out, via a digital filter, noise from the raw data. The suggested algorithm does not require elaborate computations or large data storage and can therefore be implemented on a low-cost microcomputer for fast on-line determination of BOD(5).  相似文献   

12.
A mediator-less microbial fuel cell was optimized in terms of various operating conditions. Current generation was dependent on several factors such as pH, resistance, electrolyte used, and dissolved oxygen concentration in the cathode compartment. The highest current was generated at pH 7. Under the operating conditions, the resistance was the rate-determining factor at over 500 omega. With resistance lower than 500 omega, proton transfer and dissolved oxygen (DO) supply limited the cathode reaction. A high strength buffer reduced the proton limitation to some extent. The DO concentration was around 6 mg l(-1) at the DO limited condition. The fact that oxygen limitation was observed at high DO concentration is believed to be due to the poor oxygen reducing activity of the electrode used, graphite. The current showed linear relationship with the fuel added at low concentration, and the electronic charge was well correlated with substrate concentration from up to 400 mg l(-1) of COD(cr). The microbial fuel cell might be used as a biochemical oxygen demand (BOD) sensor.  相似文献   

13.
A computer-controlled biochemical oxygen demand (BOD) analyzer has been developed for fast estimation of biochemical oxygen demand (BODst) automatically with the purpose of on-line monitoring of a process for conversion of biomass under field conditions. The instrument was tested by on-line monitoring of the connecting stream between two stages of a two-stage anaerobic process in laboratory scale. In the first stage, hydrolysis of sugar beet leaves and its conversion into volatile fatty acids and other low molecular weight substrates took place. The effluent from the first reactor was used as a feed stream to the second stage, i.e. an anaerobic contact reactor. The feed stream was sampled intermittently, diluted and analyzed by the BOD analyzer automatically in order to estimate the organic loading rate to the reactor. The results from this study demonstrated that the BOD analyzer could be a stand-alone and promising sensor device for rapid on-line monitoring of easily biodegradable organic substances in biological treatment processes.  相似文献   

14.
Woody debris (CWD) is an important habitat component in northern Gulf of Mexico coastal plain streams, where low gradients and low flows allow accumulation of CWD and promote low dissolved oxygen (DO) concentrations. We tested the influences of CWD and DO on stream macroinvertebrates experimentally by placing two surface area CWD treatments each in three concentrations of ambient DO in two streams in Louisiana, USA, with macroinvertebrates collected from ambient woody debris used as a control. We also sampled macroinvertebrates in benthic and woody debris habitats in three streams twice yearly over 2 years to examine the applicability of the experimental results. Total abundance, richness (generic), and Shannon–Wiener diversity were all higher in lower DO conditions during the experiment, and total abundance was higher in the larger CWD treatment. Stream sampling corroborated the relationship between higher diversity and low DO in both benthic and woody debris habitats, but the relationship between richness and low DO only was supported in benthic habitats. Few taxa correlated with DO or CWD in the experiment (5 of 21 taxa) or stream survey (2 of 54 taxa). Whereas most taxa were uncorrelated with experimentally manipulated and in-stream measured variables, we suggest these taxa respond as generalists to stream habitat and physicochemistry. Based on this experiment and stream sampling, we believe the majority of macroinvertebrates in these streams are tolerant of seasonally low DO conditions.  相似文献   

15.
太湖流域河流水质状况对景观背景的响应   总被引:6,自引:0,他引:6  
周文  刘茂松  徐驰  何舸  王磊  杨雪姣 《生态学报》2012,32(16):5043-5053
为探索流域水质对景观背景的响应,以太湖流域为研究对象,在0.5—24 km共9个尺度上运用冗余分析研究了土地利用、河网密度、降水量、地形等景观背景因子与河流水化学指标的关系。结果表明:2006—2010年太湖流域河流水质状况总体较差,但整体有逐渐改善的趋势,超标水质指标主要包括总磷(TP)、氨氮(AN)、生化需氧量(BOD)、化学需氧量(COD)和溶解氧(DO),上游地区主要表现为林区和平原水网区的差异,下游地区主要表现为河段上下游间的差异。河流水质受到多种景观背景因子的综合影响,并表现出尺度依赖性和区位差异性。AN、TP、DO在流域上游与聚落用地正相关,在下游则与耕地、河网密度正相关。COD、BOD在流域上游主要与自然湿地负相关,与人工湿地正相关,在下游则与坡度负相关,与河网密度正相关。总方差贡献率在上下游表现出一致的尺度依赖特征,均在较小(0.5—1 km)和较大(16 km)两个尺度上具有较高的解释能力。自然湿地和坡度,河网密度和耕地分别为上游、下游地区在较小和较大尺度上解释能力最高的景观因子。  相似文献   

16.
As a result of its wide usage in the production of polycarbonate plastics and epoxy resins, bisphenol A (BPA) is commonly detected in wastewaters. Recently, BPA became a major concern because its adverse effects as an endocrine disruptor. In this work, the biodegradation kinetics of BPA and its metabolic intermediates 4-hydroxyacetophenone (4HAP), 4-hydroxybenzaldehyde (4HB) and 4-hydroxybenzoic acid (4HBA) by BPA-acclimated activated sludge was studied using manometric respirometry (BOD) tests. For all the tested compounds, BOD curves exhibited two phases. In the first one, a fast increase of the oxygen consumption (OC) due to the active oxidation of the substrate was obtained. Then, when the substrate was exhausted, the endogenous respiration produced a slower increase of OC. A standard Monod-model with biomass growth was used to represent the OC profiles as a function of time. For all the tested compounds, a good agreement between the proposed model and the experimental data was obtained. According to their biodegradation rates, the tested compounds can be ordered as follows: BPA < 4HAP ? 4HB < 4HBA. Because the oxidation rate of BPA by BPA-acclimated activated sludge limits the rate of the whole biodegradation pathway, the accumulation of metabolic intermediates 4HAP, 4HB, and 4HBA would be negligible. To calculate the dissolved oxygen (DO) concentration (C) during the BOD tests, the oxygen transfer coefficient (kLa) of the BOD bottles was obtained using the sulfite method. Finally, a simple procedure to calculate the minimum DO concentration (Cmin) based on BOD data was developed. Calculation results demonstrated that under the tested conditions, C values were high enough as not to be the limiting substrate for the microbial growth.  相似文献   

17.
The biochemical oxygen demand (BOD) value is still a key parameter that can determine the level of organics, particularly the content of biodegradable organics in water. In this work, the effects of sample dilution, which should be done inevitably to get appropriate dissolved oxygen (DO) depletion, on the measurement of 5-day BOD (BOD5), was investigated with and without seeding using natural and synthetic water. The dilution effects were also evaluated for water samples taken in different seasons such as summer and winter because water temperature can cause a change in the types of microbial species, thus leading to different oxygen depletion profiles during BOD testing. The predation phenomenon between microbial cells was found to be dependent on the inorganic nutrients and carbon sources, showing a change in cell populations according to cell size after 5-day incubation. The dilution of water samples for BOD determination was linked to changes in the environment for microbial growth such as nutrition. The predation phenomenon between microbial cells was more important with less dilution. BOD5 increased with the specific amount of inorganic nutrient per microbial mass when the natural water was diluted. When seeding was done for synthetic water samples, the seed volume also affected BOD due to the rate of organic uptake by microbes. BOD5 increased with the specific bacterial population per organic source supplied at the beginning of BOD measurement. For more accurate BOD measurements, specific guidelines on dilution should be established.  相似文献   

18.
The subsurface riparian zone was examined as an ecotone with two interfaces. Inland is a terrestrial boundary, where transport of water and dissolved solutes is toward the channel and controlled by watershed hydrology. Streamside is an aquatic boundary, where exchange of surface water and dissolved solutes is bi-directional and flux is strongly influenced by channel hydraulics. Streamside, bi-directional exchange of water was qualitatively defined using biologically conservative tracers in a third order stream. In several experiments, penetration of surface water extended 18 m inland. Travel time of water from the channel to bankside sediments was highly variable. Subsurface chemical gradients were indirectly related to the travel time. Sites with long travel times tended to be low in nitrate and DO (dissolved oxygen) but high in ammonium and DOC (dissolved organic carbon). Sites with short travel times tended to be high in nitrate and DO but low in ammonium and DOC. Ammonium concentration of interstitial water also was influenced by sorption-desorption processes that involved clay minerals in hyporheic sediments. Denitrification potential in subsurface sediments increased with distance from the channel, and was limited by nitrate at inland sites and by DO in the channel sediments. Conversely, nitrification potential decreased with distance from the channel, and was limited by DO at inland sites and by ammonium at channel locations. Advection of water and dissolved oxygen away from the channel resulted in an oxidized subsurface habitat equivalent to that previously defined as the hyporheic zone. The hyporheic zone is viewed as stream habitat because of its high proportion of surface water and the occurrence of channel organisms. Beyond the channel's hydrologic exchange zone, interstitial water is often chemically reduced. Interstitial water that has not previously entered the channel, groundwater, is viewed as a terrestrial component of the riparian ecotone. Thus, surface water habitats may extend under riparian vegetation, and terrestrial groundwater habitats may be found beneath the stream channel.  相似文献   

19.
Gymnotiform electric fish assemblage structure is strongly correlated to dissolved oxygen (DO) availability, which exhibits considerable heterogeneity among Amazonian aquatic systems. DO is known to influence the respiratory morphology of gymnotiform fishes, and yet species-level variation among congeners endemic to alternative DO regimes has not been examined. We describe the DO environment experienced by four congeneric species of gymnotiforms (Brachyhypopomus) and correlate this to quantitative variation in a suite of gill metrics. Whitewater floodplain lakes flanking nutrient-rich whitewater rivers are seasonally hypoxic, exhibiting oxygen concentrations close to 0 mg/l from late April until September. In contrast, DO levels in blackwater floodplain lakes and in terra firme forest stream habitats remain high throughout the year. Two common species of Brachyhypopomus restricted to periodically anoxic whitewater floodplain exhibited a substantially greater gill size than two common species restricted to the perpetually well-oxygenated waters of blackwater floodplain lakes and terra firme stream systems. Discriminant Function Analysis (DFA) based on gill metrics separated the species that live in seasonally anoxic whitewater floodplain species from those that live in perpetually-well oxygenated habitats. Our observations suggest a history of adaptive divergence in the gill morphology of Brachyhypopomus associated with oxygen availability.  相似文献   

20.
【目的】松花江流域是中国最早的工业基地之一,其水生态环境遭到严重破坏,环境保护工作面临巨大挑战。开展松花江流域水质评价及典型生物类群多样性状况调查,可为松花江流域生态系统的保护和修复提供依据。【方法】于2016年7月调查整个松花江流域近岸的大型底栖动物群落组成和测定水质理化指标,开展其水质理化特征评价和生物指数评价,并探讨底栖动物群落分布与水环境因子间的关系。【结果】理化指标评价结果显示,南源松花江水质状况最差,处于中度污染;北源松花江处于轻度污染;梧桐河水质最好,处于良好状态。松花江流域3个河段的底栖动物群落结构存在空间差异性。另外,梧桐河的物种多样性最高,北源松花江次之,南源松花江最低。溶解氧和营养元素K的浓度是驱动底栖动物群落组成发生显著性差异的主要环境因子。生物指数评价结果显示,3个河段水质均处于轻度污染状态。【结论】松花江流域水质处于轻度到中度污染状态。有机污染是松花江流域面临的主要水质环境问题,对松花江流域底栖动物群落结构产生了显著影响。因此,控制有机质的输入是维持松花江流域水生态系统平衡的重要举措之一。  相似文献   