首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
BACKGROUND: The functional characteristics of the bovine mesenteric postnodal lymphatics are well-described. However there are no reports of pumping characteristics of the bovine mesenteric prenodal lymphatics. We propose that the prenodal lymphatics have adapted to the local conditions of lymph flow and are functioning differently than the postnodal vessels. METHODS AND RESULTS: To evaluate pumping in bovine prenodal mesenteric lymphatics, we observed their contractility in response to the changes in transmural pressure and imposed flow. Lymphatics (diameter approximately 460 microm) were isolated, cannulated, and pressurized. Lymphatic diameters were traced from video records; the lymphatic tone index, contraction amplitude and frequency, lymphatic pump indices were calculated. Increasing transmural pressure from 3 to 6 cm H2O produced a strong inotropic response, but did not induce a significant chronotropic response. Pumping reached its maximum at transmural pressures 6-9 cm H2O and was not significantly depressed up to 15 cm H2O, whereas pumping in postnodal lymphatics is typically depressed at transmural pressures higher than 10 cm H2O. Bovine prenodal mesenteric lymphatics also demonstrated very low sensitivity to the increases in imposed flow. CONCLUSIONS: We concluded that the functional heterogeneity exists on the intraregional levels in lymphatic nets.  相似文献   

2.
The purpose of this study was to test the hypothesis that endotoxin administration to sheep results in host-derived lymph-borne factors that modulate lymphatic pumping activity. To achieve this, two sheep were used for each experiment. In the test animal, a segment of intestinal lymphatic was isolated from all lymph input and provided with lymph from a reservoir. Pumping activity was initiated with a fixed transmural pressure applied to the test vessel, and the only input to this duct was provided by lymph from an indwelling catheter in a second donor sheep. The intravenous administration of endotoxin to the donor animals (33 micrograms/kg) generally resulted in increased pumping in the test vessels over the 1st h, but this was followed by reductions in pumping until flow stopped in all preparations. In control experiments (no endotoxin administered) pumping was unaffected. Further investigation revealed that these activities were relatively unstable and, in the case of the inhibitory material, appeared to act by decreasing the sensitivity of the vessel to changes in transmural pressure, because flow could be reestablished in the test vessels by elevating transmural pressures above the level originally chosen for the experiment. Endotoxin itself had no direct effect on sheep lymphatics in vivo or on bovine lymphatic vessels in vitro. However, the appearance of erythrocyte hemolysate (erythrolysate) in lymph was regularly observed after endotoxin infusion, and we demonstrated that erythrolysate (diluted to contain 10(-5) M hemoglobin) was a potent inhibitor of lymphatic pumping in vivo and in vitro.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

3.
The lymphatic system is an open-ended network of vessels that run in parallel to the blood circulation system. These vessels are present in almost all of the tissues of the body to remove excess fluid. Similar to blood vessels, lymphatic vessels are found in branched arrangements. Due to the complexity of experiments on lymphatic networks and the difficulty to control the important functional parameters in these setups, computational modeling becomes an effective and essential means of understanding lymphatic network pumping dynamics. Here we aimed to determine the effect of pumping coordination in branched network structures on the regulation of lymph flow. Lymphatic vessel networks were created by building upon our previous lumped-parameter model of lymphangions in series. In our network model, each vessel is itself divided into multiple lymphangions by lymphatic valves that help maintain forward flow. Vessel junctions are modeled by equating the pressures and balancing mass flows. Our results demonstrated that a 1.5 s rest-period between contractions optimizes the flow rate. A time delay between contractions of lymphangions at the junction of branches provided an advantage over synchronous pumping, but additional time delays within individual vessels only increased the flow rate for adverse pressure differences greater than 10.5 cmH2O. Additionally, we quantified the pumping capability of the system under increasing levels of steady transmural pressure and outflow pressure for different network sizes. We observed that peak flow rates normally occurred under transmural pressures between 2 to 4 cmH2O (for multiple pressure differences and network sizes). Networks with 10 lymphangions per vessel had the highest pumping capability under a wide range of adverse pressure differences. For favorable pressure differences, pumping was more efficient with fewer lymphangions. These findings are valuable for translating experimental measurements from the single lymphangion level to tissue and organ scales.  相似文献   

4.

The lymphatics maintain fluid balance by returning interstitial fluid to veins via contraction/compression of vessel segments with check valves. Disruption of lymphatic pumping can result in a condition called lymphedema with interstitial fluid accumulation. Lymphedema treatments are often ineffective, which is partially attributable to insufficient understanding of specialized lymphatic muscle lining the vessels. This muscle exhibits cardiac-like phasic contractions and smooth muscle-like tonic contractions to generate and regulate flow. To understand the relationship between this sub-cellular contractile machinery and organ-level pumping, we have developed a multiscale computational model of phasic and tonic contractions in lymphatic muscle and coupled it to a lymphangion pumping model. Our model uses the sliding filament model (Huxley in Prog Biophys Biophys Chem 7:255–318, 1957) and its adaptation for smooth muscle (Mijailovich in Biophys J 79(5):2667–2681, 2000). Multiple structural arrangements of contractile components and viscoelastic elements were trialed but only one provided physiologic results. We then coupled this model with our previous lumped parameter model of the lymphangion to relate results to experiments. We show that the model produces similar pressure, diameter, and flow tracings to experiments on rat mesenteric lymphatics. This model provides the first estimates of lymphatic muscle contraction energetics and the ability to assess the potential effects of sub-cellular level phenomena such as calcium oscillations on lymphangion outflow. The maximum efficiency value predicted (40%) is at the upper end of estimates for other muscle types. Spontaneous calcium oscillations during diastole were found to increase outflow up to approximately 50% in the range of frequencies and amplitudes tested.

  相似文献   

5.
Numerous studies on metabolic syndrome (MetSyn), a cluster of metabolic abnormalities, have demonstrated its profound impact on cardiovascular and blood microvascular health; however, the effects of MetSyn on lymphatic function are not well understood. We hypothesized that MetSyn would modulate lymphatic muscle activity and alter muscularized lymphatic function similar to the impairment of blood vessel function associated with MetSyn, particularly given the direct proximity of the lymphatics to the chronically inflamed adipose depots. To test this hypothesis, rats were placed on a high-fructose diet (60%) for 7 wk, and their progression to MetSyn was assessed through serum insulin and triglyceride levels in addition to the expression of metabolic and inflammatory genes in the liver. Mesenteric lymphatic vessels were isolated and subjected to different transmural pressures while lymphatic pumping and contractile parameters were evaluated. Lymphatics from MetSyn rats had significant negative chronotropic effects at all pressures that effectively reduced the intrinsic flow-generating capacity of these vessels by ~50%. Furthermore, lymphatics were remodeled to a significantly smaller diameter in the animals with MetSyn. Wire myograph experiments demonstrated that permeabilized lymphatics from the MetSyn group exhibited a significant decrease in force generation and were less sensitive to Ca(2+), although there were no significant changes in lymphatic muscle cell coverage or morphology. Thus, our data provide the first evidence that MetSyn induces a remodeling of collecting lymphatics, thereby effectively reducing their potential load capabilities and impairing the intrinsic contractility required for proper lymph flow.  相似文献   

6.
Lymphatic vessels exhibit rhythmical contractility in vivo and in vitro and this activity appears ti regulate lymph flow. A technique for measuring the cicurlar muscle contractions of isolated bovine mesenteric lymphatic vessel segments has been devised and utilized to study the pharmacological properties of these vessels. Non-contracting lympahtic vessels can be induced to contract rhythmically with a variety of mediators, the most potent being a stable PGH2 analogue (compound U46619), and the leukotrienes B4, C4 and D4 (threshold concentrations in the nanomolar range). Prostagladin F, noradrenaline, serotonin and histamine also elicited rhythmical activity but much higher concentrations were required. PGE2 and PGE1 were potent inhibitors of spontaneous contractions or those induced with U46619. In keeping with the diverse pharmacological effects of the metabolites of arachidonic acid, the addition of arachidonate to an isolated lymphatic vessel generated both stimulatory and inhibitory activities.It is concluded that arachidonic acid products (produced in the lymphatic vessel or entering the vessel in lymph draining the tissues) regulate lymph flow through their effects on lymphatic smooth muscle.  相似文献   

7.
The aim of this investigation was to achieve the first step toward a comprehensive model of the lymphatic system. A numerical model has been constructed of a lymphatic vessel, consisting of a short series chain of contractile segments (lymphangions) and of intersegmental valves. The changing diameter of a segment governs the difference between the flows through inlet and outlet valves and is itself governed by a balance between transmural pressure and passive and active wall properties. The compliance of segments is maximal at intermediate diameters and decreases when the segments are subject to greatly positive or negative transmural pressure. Fluid flow is the result of time-varying active contraction causing diameter to reduce and is limited by segmental viscous and valvular resistance. The valves effect a smooth transition from low forward-flow resistance to high backflow resistance. Contraction occurs sequentially in successive lymphangions in the forward-flow direction. The behavior of chains of one to five lymphangions was investigated by means of pump function curves, with variation of valve opening parameters, maximum contractility, lymphangion size gradation, number of lymphangions, and phase delay between adjacent lymphangion contractions. The model was reasonably robust numerically, with mean flow-rate generally reducing as adverse pressure was increased. Sequential contraction was found to be much more efficient than synchronized contraction. At the highest adverse pressures, pumping failed by one of two mechanisms, depending on parameter settings: either mean leakback flow exceeded forward pumping or contraction failed to open the lymphangion outlet valve. Maximum pressure and maximum flow-rate were both sensitive to the contractile state; maximum pressure was also determined by the number of lymphangions in series. Maximum flow-rate was highly sensitive to the transmural pressure experienced by the most upstream lymphangions, suggesting that many feeding lymphatics would be needed to supply one downstream lymphangion chain pumping at optimal transmural pressure.  相似文献   

8.
During spaceflight the normal head-to-foot hydrostatic pressure gradients are eliminated and body fluids shift toward the head, resulting in a diminished fluid volume in the legs and an increased fluid volume in the head, neck, and upper extremities. Lymphatic function is important in the maintenance of normal tissue fluid volume, but it is not clear how microgravity influences lymphatic pumping. We performed a detailed evaluation of the influence of simulated microgravity on lymphatic diameter, wall thickness, elastance, tone, and other measures of phasic contractility in isolated lymphatics. Head-down tail suspension (HDT) rats were used to simulate the effects of microgravity. Animals were exposed to HDT for 2 wk, after which data were collected and compared with the control non-HDT group. Lymphatics from four regional lymphatic beds (thoracic duct, cervical, mesenteric, and femoral lymphatics) were isolated, cannulated, and pressurized. Input and output pressures were adjusted to apply a range of transmural pressures and flows to the lymphatics. Simulated microgravity caused a potent inhibition of pressure/stretch-stimulated pumping in all four groups of lymphatics. The greatest inhibition was found in cervical lymphatics. These findings presumably are correlated to the cephalic fluid shifts that occur in HDT rats as well as those observed during spaceflight. Flow-dependent pump inhibition was increased after HDT, especially in the thoracic duct. Mesenteric lymphatics were less strongly influenced by HDT, which may support the idea that lymph hydrodynamic conditions in the mesenteric lymphatic during HDT are not dramatically altered.  相似文献   

9.
The lymphatic system comprises a series of elements, lymphangions, separated by valves and possessed of active, contractile walls to pump interstitial fluid from its collection in the terminal lymphatics back to the main circulation. Despite its importance, there is a dearth of information on the fluid dynamics of the lymphatic system. In this article, we describe linked experimental and computational work aimed at elucidating the biomechanical properties of the individual lymphangions. We measure the static and dynamic mechanical properties of excised bovine collecting lymphatics and develop a one-dimensional computational model of the coupled fluid flow/wall motion. The computational model is able to reproduce the pumping behavior of the real vessel using a simple contraction function producing fast contraction pulses traveling in the retrograde direction to the flow.  相似文献   

10.
Substance P (SP) is a neuropeptide associated with sensory innervation of lymphoid tissue and a suspected modulator of lymphatic function in inflammation. Only a few studies have examined the effects of SP on lymphatic contraction, and it is not clear to what extent SP acts directly on the lymphatic muscle and/or endothelium or indirectly through changes in intraluminal filling pressure secondary to increases in capillary permeability/filtration. We tested the effects of SP on the spontaneous contractions of rat isolated mesenteric lymphatic vessels under isometric and isobaric conditions, hypothesizing that low concentrations would stimulate lymphatic pumping by enhancing lymphatic muscle contraction in a manner complementary to the effect of increased preload. Under isometric conditions, SP (10 nM) dramatically enhanced lymphatic chronotropy and inotropy. Unlike guinea pig lymphatics, SP actions were not blocked by cyclooxygenase or PLA(2) inhibition. In the absence of SP, ramp increases in isometric preload resulted in x approximately 1.6 increases in contraction amplitude (Amp) and x approximately 1.7 increases in frequency (Freq). SP increased Freq by x approximately 2.4, Amp by x approximately 1.9, and the Amp-Freq product (AFP) by x approximately 3.5. Under isobaric conditions, the pressure elevation from 0.5 to 10 cmH(2)O in the absence of SP decreased Amp by x approximately 0.6 and increased Freq by x approximately 1.8. SP caused a modest increase in Amp, a robust increase in Freq at all pressures, and shifted the AFP-pressure relationship upward and leftward. Therefore, SP has substantial positive inotropic and chronotropic effects on rat lymphatic muscle, improving pump efficiency independent of the effects of preload and broadening of the working range of the lymphatic pump.  相似文献   

11.
We studied the effects of the thromboxane analog, U46619, infused into the left anterior descending (LAD) artery of intact dogs before and after producing endothelial denudation of the mid portion of the LAD. Proximal artery cross-sectional area (CSA) decreased by 47% with 0.1 microgram/min infusion of U46619 with intact and denuded endothelium, while resting CSA reduced spontaneously following denudation. Coronary resistance vessels demonstrated a marked constrictor response to U46619 with a rise in resistance and a fall in flow and myocardial O2 consumption. U46619 produces significant narrowing of proximal epicardial coronary arteries as well as resistance coronary vessels. This effect could cause ischemia in patients with moderate coronary atherosclerosis.  相似文献   

12.
The role of lymphatic vessels is to transport fluid, soluble molecules, and immune cells to the draining lymph nodes. Here, we analyze how the aging process affects the functionality of the lymphatic collectors and the dynamics of lymph flow. Ultrastructural, biochemical, and proteomic analysis indicates a loss of matrix proteins, and smooth muscle cells in aged collectors resulting in a decrease in contraction frequency, systolic lymph flow velocity, and pumping activity, as measured in vivo in lymphatic collectors. Functionally, this impairment also translated into a reduced ability for in vivo bacterial transport as determined by time‐lapse microscopy. Ultrastructural and proteomic analysis also indicates a decrease in the thickness of the endothelial cell glycocalyx and loss of gap junction proteins in aged lymph collectors. Redox proteomic analysis mapped an aging‐related increase in the glycation and carboxylation of lymphatic's endothelial cell and matrix proteins. Functionally, these modifications translate into apparent hyperpermeability of the lymphatics with pathogen escaping from the collectors into the surrounding tissue and a decreased ability to control tissue fluid homeostasis. Altogether, our data provide a mechanistic analysis of how the anatomical and biochemical changes, occurring in aged lymphatic vessels, compromise lymph flow, tissue fluid homeostasis, and pathogen transport.  相似文献   

13.
The mechanism for interstitial fluid uptake into the lymphatics remains speculative and unresolved. A system of intralymphatic valves exists that prevents reflow along the length of the lymphatic channels. However, these valves are not sufficient to provide unidirectional flow at the level of the initial lymphatics. We investigate here the hypothesis that initial lymphatics have a second, separate valve system that permits fluid to enter from the interstitium into the initial lymph channels but prevents escape back out into the tissue. The transport of fluorescent microspheres (0.31 microm) across endothelium of initial lymphatics in rat cremaster muscle was investigated with micropipette manipulation techniques. The results indicate that microspheres can readily pass from the interstitium across the endothelium into the lumen of the initial lymphatics. Once inside the lymphatic lumen, the microspheres cannot be forced out of the lumen even after elevation of the lymphatic pressure by outflow obstruction. Reaspiration of the microspheres inside the lymphatic lumen with a micropipette is blocked by the lymphatic endothelium. This blockade exists whether the aspiration is carried out at the microsphere entry site or anywhere along the initial lymphatics. Nevertheless, puncture of the initial lymphatic endothelium with the micropipette leads to rapid aspiration of intralymphatic microspheres. Investigation of lymphatic endothelial sections fixed during lymph pumping shows open interendothelial junctions not found in resting initial lymphatics. These results suggest that initial lymphatics have a (primary) valve system at the level of the endothelium. In conjunction with the classical (secondary) intralymphatic valves, the primary valves provide the mechanism that facilitates the unidirectional flow during periodic compression and expansion of initial lymphatics.  相似文献   

14.
Human femoral, internal mammary, and gastroepiploic arteries and saphenous veins are used as bypass grafts for coronary surgery or for reconstruction in arterial occlusive disease. We have characterized the contractile responses of these vessels to various agents that are liberated during cardiac or vascular surgery. In organ baths, U46619 (a stable thromboxane A2 mimetic), norepinephrine, endothelin-1, angiotensin II, and KCl caused concentration-dependent contractions in all vessels tested. Leukotriene C4 did not induce any contraction in the arteries, whereas a contraction was obtained in the saphenous vein rings. U46619 induced the most powerful contraction in all vessels tested. The pD2 values for each agent did not differ among the different vessels. When responses were expressed as a percentage of KCl-induced contraction, the contraction of endothelin-1 (151+/-5%) and leukotriene C4 (43+/-5%) was more significant on saphenous veins than on arteries. In conclusion, thromboxane A2 appears to be the most potent endogenous constricting agent on different human vascular beds. Our second finding is that saphenous veins are more sensitive to contract to leukotriene C4 and endothelin-1 than arteries. These properties may influence early and (or) long-term vein graft patency.  相似文献   

15.
Johnston M 《Lymphatic research and biology》2003,1(1):41-4; discussion 45
Despite the fact that the central nervous system parenchyma does not contain lymphatics, extracranial lymphatic vessels play a very important role in volumetric cerebrospinal fluid (CSF) transport. The most important extracranial location at which lymphatics gain access to CSF is in the nasal submucosa after CSF convects through the cribriform plate. At relatively low intracranial pressures (ICPs), the majority of cranial CSF absorption occurs through this pathway. Global CSF transport parameters in the late gestation fetus and adult sheep are very similar, even though significant numbers of arachnoid projections seem to exist only in the adult. Therefore, extracranial lymphatic vessels play an important role in CSF transport before birth and may represent the primary mechanism for CSF absorption in the neonate. Based on these considerations, hydrocephalus may involve reduced CSF transport to, or into extracranial lymphatic absorption sites.  相似文献   

16.
The passive and active length-tension relationships of isolated rat mesenteric lymphatics ( approximately 150 microm ID), and adjacent small arteries ( approximately 240 microm) and veins ( approximately 275 microm) were compared under isometric conditions using a wire myograph. About 60% of the lymphatic vessels developed spontaneous contractions in physiological saline solution at nominal preload. To maximally activate smooth muscle, 145 mM K(+) + 5 x 10(-5) M norepinephrine was used for arteries, and 145 mM K(+) + 1 x 10(-6) M substance P was used for lymphatics and veins. In response, arteries exhibited monotonic force development to a plateau level, whereas lymphatics and veins showed biphasic force development, consisting of a transient force peak followed by partial relaxation to a plateau over approximately 5 min. The passive and the active length-tension curves were similar in shape among all three vessels. However, the maximal active tension of arteries (3.4 +/- 0.42 mN/mm) was significantly greater than peak active tension (0.59 +/- 0.04 mN/mm) or plateau tension (0.20 +/- 0.04 mN/mm) in small veins and greater than peak active tension (0.34 +/- 0.02 mN/mm) or plateau tension (0.21 +/- 0.02 mN/mm) in lymphatics. Maximal active medial wall stress was similar between lymphatics and veins but was approximately fivefold higher in small arteries. For lymphatics, the pressure calculated from the optimal preload was significantly higher than that found previously in isobaric studies of isolated lymphatics, suggesting the capacity to operate at higher than normal pressures for increased responsiveness. Our results represent the first mechanical comparisons of arterial, venous, and lymphatic vessels in the same vasculature.  相似文献   

17.
Embedded into the wall of collecting lymphatic vessels and trunks, the lymphatic smooth muscles are cardinal to the functions of the lymphatic system. Their intrinsic contractile property--the intrinsic lymph pump--through rhythmical and phasic contractions of the vessels, represents the principal mechanism by which lymph flow is generated. Through changes in tonic constrictions, lymphatic smooth muscles also modulate lymph flow resistance. Lymphatic smooth muscles are sensitive to physical and chemical stimuli, mediating changes in their activity and modulating lymphatic drainage. Because lymphatic smooth muscles play such an important role in fluid transport, their dysfunction may be a component of many inflammatory disease states. This review presents recent findings on the physiology and cellular biology of lymphatic smooth muscles and discusses the importance of these cells for the function of the lymphatic system in physiological and pathophysiological situations.  相似文献   

18.
U46619双向调节系膜细胞DNA合成的研究   总被引:1,自引:0,他引:1  
Mene用血清或佛波醇肉豆寇乙酸(PMA)预失活化系膜细胞的PKC,可抑制U46619所致的IP合成及细胞内Ca~(2 )的升高,提示PKC预先活化后,可对再次活化PLC-PKC的物质起负反馈抑制作用。血清中含有血液凝固时血小板释放的血小板源性生长因子(PDGF),可活化PLC及PKC,可能对U46619的作用起负反馈抑制,使U46619促增殖作用丧失。第三,TXA_2可能直接或间接刺激前列腺素(PG)E_2或PGI_2的合成,而后两者有抑制细胞增殖的作用。不论何种机制参与,U46619这种抑制作用在病理上可能有积极意义:在正常状态下,体内肾小球系膜细胞为静息状态,肾小球合成的PG及TX极少,当肾小球产生炎症时,肾小球白细胞及血小板浸润增多,合成的PG、TX及PDGF增多,这时TX的升高可能有抑制PDGF所致细胞增殖的作用。 摘要 本实验用[~3H]TdR掺入法测定TXA_2类似物U46619对大鼠系膜细胞DNA合成的调节作用,测定系膜细胞合成的DAG及1,4,5-IP_3量,用PKC抑制剂Calphostin C预处理系膜细胞,观察其对U46619促增殖作用的影响。结果表明,U46619促进生长停滞的系膜细胞的DNA合成及IP_3的生成。本文首次证实U46619也促进DAG的生成并发现PKC抑制剂可抑制U46619的促增殖作用,提示U46619使生长停滞的系膜细胞的PLC活化,促进IP及DAG生成,进而激活PKC,促进系膜细胞DNA合成  相似文献   

19.
The chick chorioallantoic membrane (CAM) subserves gas exchange in the developing embryo and shell-less culture affords a unique opportunity for direct observations over time of individual blood vessels to pharmacologic interventions. We tested a number of lipids including prostaglandins PGE(1&2) for vascular effects and signaling in the CAM. Application of PGE(1&2) induced a decrease in the diameter of large blood vessels and a concentration-dependent, localized, reversible loss of blood flow through small vessels. The loss of flow was also mimicked by misoprostol, an agonist for 3 of 4 known PGE receptors, EP(2-4), and by U46619, a thromboxane mimetic. Selective receptor antagonists for EP(3) and thromboxane each partially blocked the response. This is a first report of the effects of prostaglandins on vasoreactivity in the CAM. Our model allows the unique ability to examine simultaneous responses of large and small vessels in real time and in vivo.  相似文献   

20.
Active (intrinsic) lymphatic pumping may be an important factor determining lymph flow from the lungs. Unfortunately, in most experiments, it is very difficult to determine the influence of active pumping vs. passive factors on lymph flow. However, 1) the pumping activity (stroke volume and frequency) of isolated lymphatic segments varies nonlinearly with transmural pressure, and 2) the lung lymph flow from awake sheep varies nonlinearly with lymphatic outflow pressure. Accordingly, if lymphatic pumping significantly influences lung lymph flow, then it should be possible to describe the sheep lung lymph flow vs. outflow pressure data with the pumping activity data. To test this, we used published lymphatic pumping activity data to develop a mathematical model of the lymphatic pump for a segment of lymphatic vessel. Flow vs. outflow pressure relationships obtained from simulations with this model were very similar to the data from sheep. Our results indicate that both passive factors and active lymphatic pumping contribute to lymph flow, and our model may allow investigators to distinguish the effects of active pumping vs. passive factors in the regulation of lymph flow.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号