首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The enantiomers of the antiinflammatory drug Etodolac were separated without derivatization on Chiralcel OD and Pirkle (R)-DNBPG columns. Enantiomeric purity can be determined in less than 10 min. Optimization of separation was evaluated using various concentrations of 2-propanol (doped with TFA) in hexane as the mobile phase. © 1993 Wiley-Liss, Inc.  相似文献   

2.
Cellulose triphenylcarbamate derivatives have been used as stationary phases for resolution of the enantiomers of the β-blockers propranolol and bupranolol by TLC. The derivatives examined were: cellulose trisphenylacarbamate (1), cellulose tris(2,3-dichlorophenyl carbamate) (2), cellulose tris(2,4-dichlorophenyl carbamate) (3), cellulose tris(2,6-dichlorophenyl carbamate) (4), cellulose tris (2,3-dimethylphenyl carbamate) (5), cellulose tris(3,4-dichlorophenyl carbamate) (6), cellulose tris(3,5-dichlorophenyl carbamate) (7), and cellulose tris(3,5-dimethylphenyl carbamate) (8). A variety of mobile phases were used to achieve useful separations and the effects of solvent polarity are also discussed. The best resolution of rac-propranolol was obtained on CSP 8 (RfR = 0.26, RfS = 0.06, α = 4.33) in mobile phase hexane:propan-2-ol (80:20 v/v). The best resolution of rac-bupranolol was obtained on CSP 5 (RfR = 0.29, RfS = 0.09, α = 3.22) in mobile phase hexane:propan-2-ol (80:20 v/v). These results demonstrated the potential of cellulose triphenylcarbamates as chiral stationary phases in TLC and indicate that this is potentially a useful method for the direct, simple, and rapid (within 30 min) resolution of racemates in the analytical control of enantiomeric purity. Physical aspects such as problems in cracking of the CSP, adhesion to plate, and interference of spot detection due to triphenylcarbamate chromphores are also discussed, along with the method employed to overcome them. Chirality 9:139–144, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

3.
This paper describes the enantiorecognition of (±)nicotine and (±)nornicotine by high-performance liquid chromatography using two derivatized cellulose chiral stationary phases (CSPs) operated in the normal phase mode. It was found that different substituents linked to the cellulose backbone significantly influence the chiral selectivity of the derivatized CSP. The results showed that, in general, the tris(4-methylbenzoyl) cellulose CSP (Chiralcel OJ) surpasses tris(3,5-dimethylphenyl carbamoyl) cellulose CSP (Chiralcel OD). On the former column, the resolution (±)nicotine and (±)nornicotine enantiomers depended largely on mobile phase compositions. For the separation of the nicotine enantiomers, the addition of trifluoroacetic acid to a 95:5 hexane/alcohol mobile phase greatly improved the enantioresolution, probably due to enhanced hydrogen bonding interactions between the protonated analytes and the CSP. For (±)nornicotine separation, a reduction in the concentration of alcohol in the mobile phase was more effective than the addition of trifluoroacetic acid. Possible solute-mobile phase-stationary phase interactions are discussed to explain how different additives in the mobile phase and different substituents on the cellulose glucose units of the CSPs affect the separation of both pairs of enantiomers. Chirality 10:364–369, 1998. Published 1998 Wiley-Liss, Inc.
  • 1 This article is a US Government work and, as such, is in the public domain in the United States of America.
  •   相似文献   

    4.
    Caccamese S  Bianca S  Carter GT 《Chirality》2009,21(6):569-577
    A direct liquid chromatographic enantioselective separation of venlafaxine and 11 analogs was obtained in the normal phase mode using Chiralpak AD. For some compounds, a comparison between the enantioseparation using coated and immobilized amylose tris(3,5-dimethylphenylcarbamate) chiral stationary phases (Chiralpak AD and Chiralpak IA, respectively) was made. The best separations were achieved on Chiralpak AD with ethanol as alcoholic modifier in a mobile phase made basic by DEA addition: separation factor ranges between 2.08 and 1.15 and resolution factor between 7.0 and 1.0. Using the same CSP and 2-propanol doped with TFA as acidic modifier, 10 compounds were enantioseparated with separation factor ranging between 1.40 and 1.04 and resolution factor between 3.1 and 0.3. The use of ethanol as alcoholic modifier also has the advantage of better solubility of the compounds in the mobile phase. The nature of the substituent (electron donating or withdrawing) affects in general the separation factor. A memory effect that involves a long equilibration time of the CSP is present when switching from an acidic mobile phase to a basic one.  相似文献   

    5.
    Kim BH  Lee SU  Kim KT  Lee JY  Choi NH  Han YK  Ok JH 《Chirality》2003,15(3):276-283
    Enantiomeric separation of pyrethroic acid methyl and ethyl esters was examined on cellulose-based chiral stationary phases (CSPs): chiralcel OD (cellulose tris(3,5-dimethylphenyl carbamate)) and chiralcel OF (cellulose tris(4-chlorophenyl carbamate)). The good resolution of pyrethroic acid esters was achieved on chiralcel OD and OF. Separation factors ranged from 1.19-5.12 for Chiralcel OD and 1.00-1.59 for chiralcel OF. Hexane/2-propanol (100:0.15, v/v %) was used as the eluent. The resolution capability of CSPs was greater chiralcel OD than chiralcel OF in the case of the pyrethroic acid esters. The flow rate was 0.8 ml/min and detection was set at 230 nm. The results of the chromatographic data and molecular mechanics suggest that steric effect was a major factor in the enantioseparation. Furthermore, the hydrogen bond between analytes and CSP played an important role in the chiral recognition.  相似文献   

    6.
    A comparison of the enantiomeric resolution of (+/-)-threo-methylphenidate (MPH) (Ritalin) was achieved on different polysaccharide based chiral stationary phases. The mobile phase used was hexane-ethanol-methanol-trifluoroacetic acid (480:9.75:9.75:0.5, v/v/v/v). Benzoic acid and phenol were used as the mobile phase additives for the enantiomeric resolution of MPH on Chiralcel OB column only. The alpha values for the resolved enantiomers were 1.34, 1.29, 1.30, and 1.24 on Chiralpak AD, Chiralcel OD, Chiralcel OB (containing 0.2 mM benzoic acid in mobile phase), and Chiralcel OB (containing 0.2 mM phenol in mobile phase) columns, respectively. The R(s) values were 1.82, 1.53, 1.19, and 1.10 on Chiralpak AD, Chiralcel OD, Chiralcel OB (containing 0.2 mM benzoic acid in mobile phase), and Chiralcel OB (containing 0.2 mM phenol in mobile phase), respectively. The role of benzoic acid and phenol as mobile phase additives is discussed.  相似文献   

    7.
    The enantiomers of various 1-(alpha-aminobenzyl)-2-naphthol and 1-(aminoalkyl)-2-naphthol analogs were separated on cellulose-tris-3,5-dimethylphenyl carbamate-based chiral stationary phases (Chiralcel OD-H and Chiralcel OD-RH), using n-hexane/2-propanol/diethylamine or phosphate buffer/organic modifier mobile phases. The 3,5-dimethylphenyl carbamoylated cellulose columns were effective in both normal and rev ersed-phase modes. The effects of the mobile phase composition, the pH, the buffer concentration, and the structures of the substituents on the 2-naphthol on the enantioseparations were studied. The absolute configuration and elution sequence were determined for 1-(1-amino-2-methylpropyl)-2-naphthol: the elution sequence was S < R.  相似文献   

    8.
    Patti A  Pedotti S  Sanfilippo C 《Chirality》2007,19(5):344-351
    The direct HPLC enantiomeric separation of several ferrocenylalcohols on the commercially available Chiralcel OD and Chiralcel OJ columns has been evaluated in normal-phase mode. Almost all the compounds were resolved on one or both chiral stationary phases (CSPs) with separation factor (alpha) ranging from 1.06 to 2.88 while the resolution (R(s)) varied from 0.63 to 12.70 In the separation of the alpha-ferrocenylalcohols 1a-e and the phenyl analogues 2a-e, which were all resolved except 1c, a similar trend in the retention behavior for the two series of alcohols was evidenced and the selectivity was roughly complementary on the two investigated CSP. For three ferrocenylacohols, chosen as model compounds, the influence of the mobile phase composition and temperature on the enantioseparation were investigated and additional information on the chiral recognition mechanism were deduced from the chromatographic behavior of their acetylderivatives.  相似文献   

    9.
    The direct HPLC separation of eight inherently chiral atropisomeric calix[4]arenes has been achieved using Chiralcel OD phase. A rationale is given for the variation of the enantioselectivity as a function of the O-alkyl or O-aryl groups. In closely related structures hydrogen bond formation between the free hydroxyl of the analyte and the chiral phase plays an important role in the chiral recognition process. © 1993 Wiley-Liss, Inc.  相似文献   

    10.
    Chiral chromatography on cellulose tris(3,5-dimethylphenyl carbamate) (Chiralcel OD) and cellulose tribenzoate (Chiralcel OB) coated stationary phases has been successfully used for the optical resolution of rac-(thio)glycidyl esters (acetate, propionate, butyrate). Glycidyl esters could sufficiently be resolved on the OD column whereas for the thio analogues baseline resolution is obtained on CSP OB using hexane/2-propanol mobile phases. The separation factor (α) and resolution (RS) depend on column temperature, eluent composition, and flow rate, respectively. Best results were obtained for the butyrates and at low temperatures in general. © 1993 Wiley-Liss, Inc.  相似文献   

    11.
    3,5‐Dinitrobenzoyl chloride was previously used for the preparation of (R)‐phenylglycinol‐ and (S)‐leucinol‐derived chiral stationary phases. In this study, 3,5‐bis(trifluoromethyl)benzoyl chloride, 2‐furoyl chloride, 2‐theonyl chloride, 10,11‐dihydro‐5H‐dibenzo[b,f]azepine‐5‐carbonyl chloride, diphenylcarbamoyl chloride, and 1‐adamantanecarbonyl chloride were used to prepare six new phenylglycinol‐derived chiral stationary phases (CSPs) and five new leucinol‐derived CSPs. Using these 11 CSPs, chiral separation of nine π‐acidic amino acid derivatives and five π‐basic compounds was performed, and the separation results were compared. An adamantyl‐derived CSP showed good separation. Chirality 28:276–281, 2016. © 2016 Wiley Periodicals, Inc.  相似文献   

    12.
    A direct, isocratic, and simple reversed-phase HPLC method was described for the separation of enantiomers of the proton pump inhibitor, rac-pantoprazole (PAN) using cellulose-based chiral stationary phases (Chiralcel OD-R and Chiralcel OJ-R). Some structurally related chiral benzimidazole sulfoxides, rac-omeprazole (OME) and raclansoprazole (LAN), were also studied. Chiralcel OJ-R was successful in the resolution of enantiomers of rac-PAN and rac-OME, while Chiralcel OD-R was most suitable for resolving the enantiomers of rac-LAN. Highest enantioselectivity to rac-PAN and rac-OME was achieved on Chiralcel OJ-R by using acetonitrile as an organic modifier, whereas methanol afforded better resolution of rac-LAN on Chiralcel OD-R than acetonitrile. Increases in buffer concentration and column temperature decreased retention and did not improve the resolution of the enantiomers on both columns. Using a mixture of 50 mM sodium perchlorate solution and acetonitrile as a mobile phase at a flow rate of 0.5 ml/min, maximum separation factors of 1.26 and 1.13 were obtained for the enantiomers of rac-PAN and rac-OME using a Chiralcel OJ-R column, while maximum separation factor of 1.16 was obtained for the enantiomers of rac-LAN using a Chiralcel OD-R column. © 1995 Wiley-Liss, Inc.  相似文献   

    13.
    Gas chromatographic study on chiral separation of PCBs was performed in a series of capillary columns coated with 0.1-μm film of modified cyclodextrin (CD) stationary phases. The preparation of columns included the investigation into the effect of the content of cyclodextrin derivative in polysiloxane, the type of polysiloxane and temperature of analysis on the quality of separation and retention of atropisomers of 15 selected PCB congeners. The separation properties towards PCBs of stationary phase heptakis(2,3-di-O-methyl-6-O-tert-butyl-dimethylsilyl)-β-CD dissolved in SE-30, SE-54, and OV-1701, were compared with those of 6-monokis-octamethylene-permethyl-β-CD anchored to polydimethylsiloxane polymer (ChirasilDex column, Chrompack, Middelburg, The Netherlands) and octakis(2,6-di-O-methyl-3-O-pentyl)-γ-CD in OV-1701 (MEGA, Legnano (MI), Italy). The correctness of quantitative enantiomer ratio determination was assesed by splitless analysis of PCBs reference solutions in concentration of 1.25–125 ng/ml (PCBs 45 and 91) and 2.5–250 ng/ml (PCB 95) (the PCB congeners are numbered according to IUPAC). Chirality 10:540–547, 1998. © 1998 Wiley-Liss, Inc.  相似文献   

    14.
    Three fungicidal triazolyl alcohols (triadimenol, hexaconazole, and cis/trans‐1‐4‐chlorophenyl‐2‐1H‐1,2,4‐triazol‐1‐yl‐cycloheptanol) were completely separated into enantiomers by chiral HPLC using polysaccharide‐based chiral stationary phases. A better separation was achieved on cellulose and amylose carbamate phases compared with a cellulose ester phase. Peak shapes were almost symmetrical except for two cases, where tailing of the first eluted enantiomer and unusual symmetric peak broadening were observed. The effect of eluents on enantioseparation was also investigated. Chirality 11:195–200, 1999. © 1999 Wiley‐Liss, Inc.  相似文献   

    15.
    A β-cyclodextrin bonded stationary phase was employed for the enantioresolution of propranolol and several analogues in conjunction with various polar organic mobile phases. The effects of structural alterations in the non-polar regions of the analytes were found to exert profound changes upon chiral resolution and capacity values, indicating that features which cannot hydrogen-bond with the cyclodextrin molecule still play an important role in this chiral recognition process. This was linked to a repulsive steric effect facilitating the necessary conditions for chiral resolution. The degree of ionization of the analytes and the type and concentration of organic modifier used were also seen to influence the analytes1 enantio-selectivity and capacity values. © 1996 Wiley-Liss, Inc.  相似文献   

    16.
    In the present study 21 different chiral aminotetralins were used to investigate the mechanism behind their enantiomeric resolution (Rs) on a commercially available high-performance liquid chromatography (HPLC) cellulose tris-3,5-dimethylcarbamate stationary phase. The differences in the chemical structures of the aminotetralins used were never directly located on the chiral carbon. Their chromatographic behavior was studied for two eluent compositions at six different temperatures. Hydrogen bonding and π? π interactions are two possible solute–chiral stationary phase (CSP) interactions. Differences between the enantiomers in their spatial arrangement of positions involved in solute–CSP interactions were the major forces behind enantiomeric separation. Lowering the temperature increased the Rs for the aminotetralins having π-electrons not directly bonded to that part of the molecule where the hydrogen bonding with the CSP is located. Primary amines and secondary amines, with a sufficiently short N-alkyl substituent, showed a decrease of Rs with lower temperatures, all other aminotetralins yielding an increase of Rs with lower temperatures. © 1992 Wiley-Liss, Inc.  相似文献   

    17.
    The direct enantiomeric separation of 32 racemic 2-amidotetralins on the commercially available tris-(3,5-dimethylphenylcarbamate) derivative of cellulose, coated on silica gel (Chiralcel OD), is presented. To date, the selection of a column for the chiral separation of a racemic mixture is done empirically. Studying the impact of small changes in the chemical structure of a series of amidotetralins on the separation behavior may help to give an insight in the chiral recognition mechanism. The amidotetralins differed structurally in three of their substituents, which were never directly located on the chiral carbon atom. The enantiomers of 24 out of 32 amidotetralins could be resolved with a resolution >1.5. Hydrogen bonding and π-π interactions are supposed to be the major analyte-chiral stationary phase (CSP) interactions. However, the spatial arrangement of the enantiomers may play an important role too. Increasing the bulkiness of the acyl substituent led to an increase in the resolution (RS), whereas a more bulky substituent on the aromatic ring resulted in a very low resolution. The introduction of a chlorine atom into the acyl substituent additionally increased the resolving power. Chirality 8:574–578, 1996. © 1997 Wiley-Liss, Inc.  相似文献   

    18.
    The direct HPLC enantioseparation of Mianserin and a series of aptazepine derivatives is accomplished on polysaccharide-based chiral stationary phases (CSPs). The resolutions are performed on the coated-type Chiralcel OD and Chiralpak AD CSPs and on the first commercially available immobilized-type Chiralpak IA CSP, in normal-phase and polar-organic modes. The complete separation of enantiomers of all racemates investigated was successfully achieved under at least one of CSP/eluent combinations employed. Pure alcohols such ethanol or 2-propanol, with a fixed percentage of DEA added, serve as valuable alternatives to the more common n-hexane-based normal-phase eluents in resolution of Mianserin on the AD CSP. In order to study the chiroptical properties of aptazepine derivatives, chromatographic resolutions are carried out at semipreparative scale using Chiralpak AD and Chiralpak IA as CSPs. Nonconventional dichloromethane-based eluents have permitted to expand the chiral resolving ability of the immobilized Chiralpak IA CSP and to perform mg-scale enantioseparations with an analytical-size column. Assignment of the absolute configuration of the separated enantiomers is empirically established by comparing their chiroptical data with those of structurally related Mianserin.  相似文献   

    19.
    The enantiomers of mandelic acid and its analogs have been chromatographically separated on a chiral stationary phase (CSP) derived from 4‐(3,5‐dinitrobenzamido) tetrahydrophenanthrene. The rationale of separations of these compounds is discussed with respect to the method development for determining enantiomeric purity and possibility of obtaining enantiomerically pure materials by high‐pressure liquid chromatography. The relationship of analyte structure to the extent of enantiomeric separation has been examined and separation factors (α) are presented for various groups of structurally related compounds. Chiral recognition models have been suggested to account for the observed separations. These models provide mechanistic insights into the chiral recognition process. Chirality 2010. © 2009 Wiley‐Liss, Inc.  相似文献   

    20.
    The chromatographic parameters for 12 structurally related compounds in the 4a-methyl-2,3,4,4a-tetrahydro-1H-fluorene and 4a-methyl-1,2,3,4,4a,9a-hexahydro-fluoren-9-one series are reported on CTA-I and Chiralcel OJ chiral stationary phases. Arrangement of the k' values according to configurationally related enantiomer series (Class I and Class II) and not according to the actual order of elution, allows the treatment of the data by linear correlation with structure and substituent effect. A detailed analysis of the capacity factor variation with respect to the structural changes shows clearly that the framework and substitution effects do not result in the same response on the two cellulose ester chiral stationary phases. More interestingly, it emerges that chiral discimination may be attributed to certain areas of the molecule, these areas being different in the interaction within CTA-I and Chiralcel OJ. Furthermore, our analysis points out the relevance of attempting to develop quantitative relationships for configurationally related series of enantiomers (in our case Class I and Class II), the main effort being devoted to the understanding of the capacity factor variation in each class rather than of the α values, which are derived entities. Chirality 10:522–527, 1998. © 1998 Wiley-Liss, Inc.  相似文献   

    设为首页 | 免责声明 | 关于勤云 | 加入收藏

    Copyright©北京勤云科技发展有限公司  京ICP备09084417号