首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
AIMS: The aims of the present study were to: (i) analyse a group of antimicrobial agents and to select the most active against test microbial strains; (ii) test the effect of the antimicrobial treatment on air filters in order to reduce microbial colonization. METHODS AND RESULTS: Different kinds of antimicrobial agents were analysed to assess their compatibility with the production process of air filter media. The minimal inhibitory concentration for each antimicrobial agent was determined against a defined list of microbial strains, and an antimicrobial activity assay of filter prototypes was developed to determine the most active agent among the compatible antimicrobials. Then, the most active was chosen and added directly to the filter during the production process. The microbial colonization of treated and untreated filter media was assessed at different working times for different incubation times by stereomicroscope and scanning electron microscope analysis. Some of the antimicrobial agents analysed were more active against microbial test strains and compatible with the production process of the filter media. Filter sections analysis of treated filter media showed a significantly lower microbial colonization than those untreated, a reduction of species both in density and varieties and of the presence of bacteria and fungal hyphae with reproductive structures. CONCLUSIONS: This study demonstrated the ability of antimicrobial treatments to inhibit the growth of micro-organisms in filter media and subsequently to increase indoor air quality (IAQ), highlighting the value of adding antimicrobials to filter media. SIGNIFICANCE AND IMPACT OF THE STUDY: To make a contribution to solving the problem of microbial contamination of air filters, by demonstrating the efficacy of incorporating antimicrobial agents in the filter media to improve IAQ and health.  相似文献   

2.
A mineral coating develops on the filter grain surface when groundwater is treated via rapid sand filtration in drinking water production. The coating changes the physical and chemical properties of the filter material, but little is known about its effect on the activity, colonization, diversity, and abundance of microbiota. This study reveals that a mineral coating can positively affect the colonization and activity of microbial communities in rapid sand filters. To understand this effect, we investigated the abundance, spatial distribution, colonization, and diversity of all and of nitrifying prokaryotes in filter material with various degrees of mineral coating. We also examined the physical and chemical characteristics of the mineral coating. The amount of mineral coating correlated positively with the internal porosity, the packed bulk density, and the biologically available surface area of the filter material. The volumetric NH4+ removal rate also increased with the degree of mineral coating. Consistently, bacterial 16S rRNA and amoA abundances positively correlated with increased mineral coating levels. Microbial colonization could be visualized mainly within the outer periphery (60.6 ± 35.6 μm) of the mineral coating, which had a thickness of up to 600 ± 51 μm. Environmental scanning electron microscopic (E-SEM) observations suggested an extracellular polymeric substance-rich matrix and submicron-sized bacterial cells. Nitrifier diversity profiles were similar irrespective of the degree of mineral coating, as indicated by pyrosequencing analysis. Overall, our results demonstrate that mineral coating positively affects microbial colonization and activity in rapid sand filters, most likely due to increased volumetric cell abundances facilitated by the large surface area of internal mineral porosity accessible for microbial colonization.  相似文献   

3.
Summary New and used cellulosic air filters for HVAC systems including those treated with antimicrobials were suspended in vessels with a range of relative humidities (55–99%) and containing non-sterile potting soil which stimulates fungal growth. Most filters yielded fungi prior to suspension in the chambers but only two of 14 nontreated filters demonstrated fungal colonization following use in HVAC systems. Filters treated with antimicrobials, particularly a phosphated amine complex, demonstrated markedly less fungal colonization than nontreated filters. In comparison with nontreated cellulosic filters, fungal colonization of antimicrobial-treated cellulosic filters was selective and delayed.  相似文献   

4.
Aims: To assess the effectiveness of iodine-treated biocidal filter media against bacterial spore aerosols. Methods and Results: Bacillus subtilis spores were aerosolized and introduced into a filtration system. Both treated and untreated filters exhibited high viable removal efficiency (>99·996%) with negligible variation in pressure drop during the entire experiment. The viability of collected spores on the filter was investigated by enumeration of spores extracted from the filter by vortexing. At room temperature and low relative humidity (RH), the survival fraction of the treated filter was significantly lower than that of the untreated filter (P-value < 0·05). Meanwhile, at room temperature and high RH and at high temperature and high RH, the survival fractions on the treated medium were statistically the same as the untreated control at room temperature and low RH. Conclusions: Both treated and untreated filters achieved excellent viable removal efficiency for spores. The pressure drop of the treated filter was not affected by the iodine treatment. The viability of collected bacterial spores was decreased because of the exertion of iodine disinfectant. Significance and Impact of the Study: The evaluation demonstrates that the iodine-treated filter is a viable medium for respiratory protection against infectious spore aerosols. The results warrant further evaluation of smaller biological agents, which exhibit higher penetration.  相似文献   

5.
AIMS: The effect of copper on the degradation by soil micro-organisms of phenanthrene, a polycyclic aromatic hydrocarbon, was investigated. METHODS AND RESULTS: Inert nylon filters were incubated in the soil for 28 days at 25 degrees C. Each filter was inoculated with a soil suspension, phenanthrene (400 ppm), copper (0, 70, 700 or 7000 ppm) and nitrogen/phosphorus sources. The filters were assessed for phenanthrene degradation, microbial respiration and colonization. Phenanthrene degradation proceeded even at toxic copper levels (700/7000 ppm), indicating the presence of phenanthrene-degrading, copper-resistant and/or -tolerant microbes. However, copper at these high levels reduced microbial activity (CO2 evolution). CONCLUSION: High levels of copper caused an incomplete mineralization of phenanthrene and possible accumulation of its metabolites. SIGNIFICANCE AND IMPACT OF THE STUDY: The presence of heavy metals in soils could seriously affect the bioremediation of PAH-polluted environments.  相似文献   

6.
The Upjohn Company uses filtration to remove microorganisms and particulates from air and other gases which may come in contact with sterile products. To validate the microbial retentivity of these filters, they were challenged with an aerosol of Bacillus subtilis var niger spores. An aerosol challenge was used because it more closely simulated the use for which these filters were designed. The test apparatus was constructed of autoclavable components using a jet-type nebulizer and heated air mixing tube. Characterization of the aerosol particle size distribution with a particle size analyzer demonstrated that 80% of the particles had a diameter of x 3.0 times;m and that the particles had a mean mass diameter of 1.9 times;m with a geometric standard deviation of 1.8 times;m. Studies conducted with aerosols of Bacillus subtilis var niger spores demonstrated that the test apparatus could recover ca. 50% of the spores that were aerosolized. Hydrophobic filters from various manufactures were challenged with an aerosol of at least 10(8) spores of Bacillus subtilis. All filters tested could retain at least 10(9) spores when physical integrity of the filter was verfield.  相似文献   

7.
In tomato soilless culture, slow filtration allows one to control the development of diseases caused by pathogenic microorganisms. During the disinfecting process, microbial elimination is ensured by mechanical and biological factors. In this study, system efficacy was enhanced further to a biological activation of filter by inoculating the pozzolana grains contained in the filtering unit with 5 selected bacteria. Three strains identified as Pseudomonas putida and 2 as Bacillus cereus came from a filter whose high efficiency to eliminate pathogens has been proven over years. These 5 bacteria displayed either a plant growth promoting activity (P. putida strains) or antagonistic properties (B. cereus strains). Over the first months following their introduction in the filter, the bacterial colonisation of pozzolana grains was particularly high as compared to the one observed in the control filter. Conversely to Bacillus spp. populations, Pseudomonas spp. ones remained abundant throughout the whole cultural season. The biological activation of filter unit very significantly enhanced fungal elimination with respect to the one displayed by the control filter. Indeed, the 6-month period needed by the control filter to reach its best efficacy against Fusarium oxysporum was shortened for the bacteria-amended filter; in addition, a high efficacy filtration was got as soon as the first month. Fast colonization of pozzolana grains by selected bacteria and their subsequent interaction with F. oxysporum are likely responsible for filter efficiency. Our results suggest that Pseudomonas spp. act by competition for nutrients, and Bacillus spp. by antibiosis and (or) direct parasitism. Elimination of other fungal pathogens, i.e., Pythium spp., seems to differ from that of Fusarium since both filters demonstrated a high efficacy at the experiment start. Pythium spp. elimination appears to mainly rely on physical factors. It is worth noting that a certain percentage of the 5 pozzolana-inoculated bacteria failed to colonise the filter unit and were, thus, driven to the plants by the nutrient solution. Their contribution to the establishment of a beneficial microbial community in the rhizosphere is discussed.  相似文献   

8.
Exposure to bioaerosols causes various adverse health effects including infectious and respiratory diseases, and hypersensitivity. Controlling exposure to bioaerosols is important for disease control and prevention. In this study, we evaluated the efficacies of various functional filters coated with antimicrobial chemicals in deactivating representative microorganisms on filters or as bioaerosols. Tested functional filters were coated with different chemicals that included (i) Ginkgo and sumac, (ii) Ag-apatite and guanidine phosphate, (iii) SiO2, ZnO, and Al2O3, and (iv) zeolite. To evaluate the filters, we used a model ventilation system (1) to evaluate the removal efficiency of bacteria (Escherichia coli and Legionella pneumophila), bacterial spores (Bacillus subtilis spore), and viruses (MS2 bacteriophage) on various functional filters, and (2) to characterize the removal efficiency of these bioaerosols. All experiments were performed at a constant temperature of 25 degrees C and humidity of 50%. Most bacteria (excluding B. subtilis) rapidly decreased on the functional filter. Therefore, we confirmed that functional filters have antimicrobial effects. Additionally, we evaluated the removal efficiency of various bioaerosols by these filters. We used a six-jet collision nebulizer to generate microbial aerosols and introduced it into the environmental chamber. We then measured the removal efficiency of functional filters with and without a medium-efficiency filter. Most bioaerosol concentrations did not significantly decrease by the functional filter only but decreased by a combination of functional and medium-efficiency filter. In conclusion, functional filters could facilitate biological removal of various bioaerosols, but physical removal of these by functional was minimal. Proper use of chemical-coated filter materials could reduce exposure to these agents.  相似文献   

9.
To reliably determine intracellular metabolite concentrations in microorganisms, accurate sampling and sample inactivation strategies are crucial. Here, we present a method for automated fast filtration and on‐filter quenching of microbial samples to overcome metabolite leakage induced by cold shock and significantly reduce the sampling and treatment time compared to manual filtration methods. The whole process of sampling, sample filtration, filter wash, and quenching of the filter with liquid nitrogen was finished in less than 6–15 s, depending on the experimental setup. By integration into an automated fast sampling device, we compared our method to the conventional methanol quenching method and showed that intracellular amino acid contents in Escherichia coli were significantly increased (≥75%) with our fast filtration and on‐filter quenching method. Furthermore, we investigated different filter types for the fast filtration and the efficiency of metabolite extraction from cells held on filters. Additionally, we found that the fast filtration behaves considerably different during exponential and nonexponential growth, probably due to variations of cell morphologies. Overall, we demonstrated that the automation of the fast filtration method significantly reduces the time for filtration and quenching and hence enlarge the number of metabolites that can be quantified with this leakage‐free sampling method.  相似文献   

10.
Viral filtration is a critical step in the purification of biologics and in the monitoring of microbiological water quality. Viral filters are also essential protection elements against airborne viral particles. The present review first focuses on cellulose-based filter media currently used for size-exclusion and/or adsorptive filtration of viruses from biopharmaceutical and environmental water samples. Data from spiking studies quantifying the viral filtration performance of cellulosic filters are detailed, i.e., first, the virus reduction capacity of regenerated cellulose hollow fiber filters in the manufacturing process of blood products and, second, the efficiency of virus recovery/concentration from water samples by the viradel (virus adsorption–elution) method using charge modified, electropositive cellulosic filters or conventional electronegative cellulose ester microfilters. Viral analysis of field water samples by the viradel technique is also surveyed. This review then describes cellulose-based filter media used in individual protection equipment against airborne viral pathogens, presenting innovative filtration media with virucidal properties. Some pros and cons of cellulosic viral filters and perspectives for cellulose-based materials in viral filtration are underlined in the review.  相似文献   

11.
Robust filtering techniques capable of efficiently removing particulates and biological agents from water or air suffer from plugging, poor rejuvenation, low permeance, and high backpressure. Operational characteristics of pressure-driven separations are in part controlled by the membrane pore size, charge of particulates, transmembrane pressure and the requirement for sufficient water flux to overcome fouling. With long term use filters decline in permeance due to filter-cake plugging of pores, fouling, or filter deterioration. Though metallic filter tube development at ORNL has focused almost exclusively on gas separations, a small study examined the applicability of these membranes for tangential filtering of aqueous suspensions of bacterial-sized particles. A mixture of fluorescent polystyrene microspheres ranging in size from 0.5 to 6 microm in diameter simulated microorganisms in filtration studies. Compared to a commercial filter, the ORNL 0.6 microm filter averaged approximately 10-fold greater filtration efficiency of the small particles, several-fold greater permeance after considerable use and it returned to approximately 85% of the initial flow upon backflushing versus 30% for the commercial filter. After filtering several liters of the particle-containing suspension, the ORNL composite filter still exhibited greater than 50% of its initial permeance while the commercial filter had decreased to less than 20%. When considering a greater filtration efficiency, greater permeance per unit mass, greater percentage of rejuvenation upon backflushing (up to 3-fold), and likely greater performance with extended use, the ORNL 0.6 microm filters can potentially outperform the commercial filter by factors of 100-1,000 fold.  相似文献   

12.
A membrane filtration/bioluminescence system was developed for the differentiation and quantitation of mixed populations of microorganisms. Samples containing microorganisms were filtered through two membrane filters of descending pore size. The microorganisms retained on the filter contain ATP that can be extracted and measured on the filter via the firefly luciferase-luciferin bioluminescence assay. Results, obtained in less than 20 min, show a good correlation (r greater than or equal to 0.95) between the light produced and the number of organisms in the sample. Using these techniques, Escherichia coli can be separated from yeast or mold and measured in samples containing both microorganisms. When lysostaphin is used to selectively lyse Staphylococci on the filter, the specific quantification of these bacteria among other microorganisms can also be accomplished. The filtration/bioluminescence technique offers the potential of being a rapid and sensitive method to differentiate and detect microorganisms, by selective sizing or lysing, in a variety of samples.  相似文献   

13.
Wang Z  Banks C 《Biodegradation》2006,17(5):415-422
The research examines the potential for bio-clogging in filter packs containing fine sand of the type typically used in extraction wells for pumping leachates containing fine particulate matter, such as cement kiln dust (CKD). Three filter media with different particle sizes were used: 1.7–4.75, 0.35–1.0, and 0.235–0.45 mm. Each sand filter was tested using a leachate recirculating column reactor with a free drainage layer, on top of which was placed the filtration medium which was kept saturated and at a positive hydrostatic head by a 2-l reservoir of leachate. The leachate was collected from a landfill site that had been used for the co-disposal of municipal solid waste (MSW) and CKD. The leachate used was filtered by passing through a Whatman GFA filter paper before being added to the reactors in order to eliminate as far as possible the non-biological clogging which might have resulted from the introduction of particulate matter in the form of CKD. The filters and a control experiment were run under anaerobic conditions at 35 °C. The bio-clogging potential was observed by taking differential manometer readings from manometers located in the drainage and reservoir sections of the reactor. No clogging was detected using the coarser of the filter media, but there was some clogging when a finer filter medium was used. Head space gas analysis indicated that methanogenic activity was inhibited and analysis of the liquid phase indicated that the microbial process responsible for removal of chemical oxygen demand (COD) was principally one of sulphate reduction.  相似文献   

14.
In this study we have assessed the capacity of five fungal and two bacterial species to biodegrade glass fiber acrylic composite filters which are utilized in air conditioners. The strains used were Trichoderma harzianum (2 strains), Trichoderma koningii, Penicillium spp., Aspergillus niger, Pseudomonas aeruginosa and Pseudomonas fluorescens. Pre-sterilized filters were incubated in solid or liquid media at 30 °C for 21 days. Biodegradability was monitored by evaluating microbial colonization, increase in biomass and weight loss of filters coupons. Among the species under investigation, the two strains of T. harzianum (MYA198 and BCC5828) showed the best biodegradability performance and were used to analyse total carbon and esterase activity. Our results clearly indicate that cells grown in the presence of shredded filters display a hydrolytic activity and lead to a consistent removal of the organic portion of the tested filters. This study suggests that a solid state fermentation process in suitable bioreactors based on T. harzianum species could be a suitable approach to acrylic composite filter biodegradation.  相似文献   

15.
The effect of different membrane filters on the bioactivity of tomato root exudates was tested in an in vitro assay addressing the germination of microconidia of the soil-borne fungus Fusarium oxysporum f. sp. lycopersici . Membrane filtration of unsterile root exudates with filters of different membrane materials and filter brands resulted in an increased microconidia germination. This effect varied depending on the used membrane filter but was lacking when sterile root exudates were used. The alteration of the bioactivity of unsterile root exudates therefore seems to be due to the presence of microbial contaminants. The varying effects of different filter brands may be due to their differential potential of retaining inhibitory compounds. When working with root exudates, such effects of membrane filtration have to be taken into account.  相似文献   

16.
Anodic aluminum oxide (AAO) filters have high porosity and can be manufactured with a pore size that is small enough to quantitatively capture viruses. These properties make the filters potentially useful for harvesting total microbial communities from water samples for molecular analyses, but their performance for nucleic acid extraction has not been systematically or quantitatively evaluated. In this study, we characterized the flux of water through commercially produced nanoporous (0.02 μm) AAO filters (Anotop; Whatman) and used isolates (a virus, a bacterium, and a protist) and natural seawater samples to test variables that we expected would influence the efficiency with which nucleic acids are recovered from the filters. Extraction chemistry had a significant effect on DNA yield, and back flushing the filters during extraction was found to improve yields of high-molecular-weight DNA. Using the back-flush protocol, the mass of DNA recovered from microorganisms collected on AAO filters was ≥100% of that extracted from pellets of cells and viruses and 94% ± 9% of that obtained by direct extraction of a liquid bacterial culture. The latter is a minimum estimate of the relative recovery of microbial DNA, since liquid cultures include dissolved nucleic acids that are retained inefficiently by the filter. In conclusion, we demonstrate that nucleic acids can be extracted from microorganisms on AAO filters with an efficiency similar to that achievable by direct extraction of microbes in suspension or in pellets. These filters are therefore a convenient means by which to harvest total microbial communities from multiple aqueous samples in parallel for subsequent molecular analyses.  相似文献   

17.
To detect low levels of microorganisms in environmental samples by using polymerase chain reaction (PCR)-gene probe detection, samples were concentrated by filtration. Fluoropore (Millipore Corp.) filters were compatible with PCR DNA amplification, whereas various other filters including nitrocellulose and cellulose acetate filters inhibited PCR amplification. By concentrating cells on Fluoropore filters and releasing the DNA by freeze-thaw cycling, PCR DNA amplification could be performed without removing the filter. Concentration with Fluoropore FHLP and FGLP filters permitted the detection of single cells of microorganisms in 100-ml samples by PCR-gene probes.  相似文献   

18.
To detect low levels of microorganisms in environmental samples by using polymerase chain reaction (PCR)-gene probe detection, samples were concentrated by filtration. Fluoropore (Millipore Corp.) filters were compatible with PCR DNA amplification, whereas various other filters including nitrocellulose and cellulose acetate filters inhibited PCR amplification. By concentrating cells on Fluoropore filters and releasing the DNA by freeze-thaw cycling, PCR DNA amplification could be performed without removing the filter. Concentration with Fluoropore FHLP and FGLP filters permitted the detection of single cells of microorganisms in 100-ml samples by PCR-gene probes.  相似文献   

19.
A mathematical model for the leukocyte filtration process   总被引:1,自引:0,他引:1  
Leukocyte filters are applied clinically to remove leukocytes from blood. In order to optimize leukocyte filters, a mathematical model to describe the leukocyte filtration process was developed by modification of a general theoretical model for depth filtration. The model presented here can be used to predict the time-dependent leukocyte filtration as a function of cell-cell interaction in the filter, filter efficiency, filter capacity, filter dimensions, and leukocyte concentration in the suspension applied to the filter. The results of different leukocyte filtration experiments previously reported in the literature could be well described by the present model. (c) 1995 John Wiley & Sons, Inc.  相似文献   

20.
BACKGROUND: Contamination of blood products by white blood cells leads to a risk of transmission of infectious agents, particularly abnormal prion protein, the probable causative agent of new-variant Creutzfeldt-Jakob disease. Blood product filtration could reduce this risk, but the filtration systems might generate potentially infectious membrane fragments. We developed an original flow cytometric method that allows the detection and quantification of membrane fragments in filtered products and the evaluation of the quantity of destroyed cells. METHODS: This method has four technical requirements: cytofluorometric acquisition of forward scatter parameters on a log scale, use of a fluorescent aliphatic reporter molecule (PKH26-GL) to identify membrane fragments, quantification with fluorescent beads, and the drawing up of a standard curve on the basis of cells destroyed by freezing/thawing to generate cell debris (i.e., quantity of membrane fragments measured versus quantity of destroyed cells). RESULTS AND CONCLUSIONS: This original method can be used to test new filtration devices and it allows optimization of the filtration process or comparison of different filtration systems. We tested the method with three commercial white cell removal filters. We demonstrated that it is possible to evaluate the filter quality, particularly the likelihood of fragment removal during the filtration process.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号