首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The flameless atomic absorption method described here is a simple, rapid, accurate microtechnique for determining zinc in aqueous solutions, serum, or urine. It requires no sample pretreatment, only 1.0 μl of sample per determination, no correction for viscosity differences between sample and standard solutions, and is not subject to ionic or organic interference. The average recovery of added zinc in serum is 97.5% and in urine is 97.6%. The values obtained for serum (mean ± SD: 94.6 ± 11.0 μAg/100 ml; N = 25) and urine (range: sol600–1000 μg24 hr; N = 4) are comparable to the values reported in the literature. The coefficient of variation was less than 5.0% in all cases. The qualitative concentration limit was 0.009 μg100 ml. The techniques and instrumentation described are also applicable to a number of trace minerals of common interest.  相似文献   

2.
Pituitary dwarfism (hGHD) is known to be associated with trace element deficiency, which causes improper functioning of the involved endocrine system. Previously, we reported on the head hair concentrations of zinc, copper, manganese, and iron from a total of 418 normal subjects (154 male and 264 female). In this report, we analyzed the head hair concentrations of the same four trace metals of 103 hGHD children (60 male and 43 female) under treatment with human growth hormone (hGH). These subjects ranged in age from 5 to 18 yr. The results were compared with 338 agematched normal subjects (120 male and 218 female). Both male and female hGHD showed approx 1.7 times higher zinc concentrations than normal subjects. Cheruvanky et al. reported a similar trend but with a slightly lower difference between hGHD and normal subjects. The average copper content in the hair of both male and female subjects also showed higher values for the hGHD than for the normal subjects, a trend similar to the values reported by Teraoka et al. In the case of manganese, the concentrations in hair of the hGHD were approx 50% of the values in the normal subjects. Head hair concentrations of iron in the hGHD were commensurate with the normal subjects. Because the content of trace elements in hair varies with the age of subjects, as a control, we investigated the head hair concentration of zinc from 20 healthy girls ranging in age from 10 to 18 yr. The average zinc concentration decreased from 10 to 12 yr, but no clear relation to age was observed from 13 yr and older. These trends were similar to our previous report. The zinc concentration in hair and body weight gain over a year was negatively correlated. The age variation in the content of zinc, copper, manganese, and iron in hair was measured comparing hGHD with the normal subjects in various ages. Concerning the zinc-level variation of hGHD and normal subjects, there were conspicuous differences between hGHD and normal subjects. For copper, the variations in concentration with age were similar to zinc. Regarding the age variations for manganese, hGHD had lower concentrations in hair compared to the normal subjects throughout adolescence (11–18 yr). We have studied the effects between the hair and these trace element concentrations in hGHD before and after hGH administration. These results suggest that hGH affects the metabolism of these trace elements.  相似文献   

3.
4.
5.
The authors present a simple and rapid method for assaying ultrafilterable copper (Cu UF) and albumin-bound copper (Cu ALB). It is based on the ultrafiltration of serum in the presence of ethylenediaminetetraacetic acid (EDTA), used to prevent adsorption on the membranes. EDTA at 0.4 g/L has no effect on the equilibrium of serum copper vectors and enables Cu UF to be assayed by flameless atomic absorption. EDTA at 2 g/L, is used to assay total exchangeable copper (CU EXC) (ultrafilterable+albumin-bound). The evaluation criteria of the method are furnished, as are the normal values in healthy subjects: 14.6 μg/L for Cu UF and 87 μg/L for Cu EXC. Finally, the usefulness of the methods described here for the diagnosis of Wilson's and Menkes' disease was demonstrated.  相似文献   

6.
A simple and reliable method is described which combines ultrafiltration technique with atomic absorption spectrophotometry to determine the Zn fractions in human blood plasma and seminal plasma. Ultrafiltrable, loosely bound, and firmly bound Zn can be measured using this method in the presence or absence of ethylene-diaminetetraacetic acid (EDTA). The YMT membranes for the ultrafiltration must be rinsed thoroughly before use. In contrast to Zn in blood plasma, a large part of Zn in the seminal plasma was found to be ultrafiltrabe. This method can be applied to study the physiologically active part of Zn in body fluids related to various disease states.  相似文献   

7.
Summary A method is described by which the Na+ and K+ content in 0.5 mm sections of single roots of Hordeum distichon L. and Atriplex hortensis L. can be determined by use of flameless atomic absorption spectroscopy. By this method the longitudinal profiles of K+ and Na+ along low salt roots and roots which had been equilibrated with or grown in K+-free 1 mM Na+-solution were determined. The profiles reveal that high K+/Na+ ratios in the cytoplasm are maintained also in K+-free solutions. In solutions containing 1 mM Na+ a high K+/Na+ selectivity was found to be dependent on sufficient aeration. From the ion profiles the cytoplasmic (110 mM) and vacuolar (20 mM) K+ concentration in low salt barley roots—values which are unobtainable by compartmental analysis—could be estimated.  相似文献   

8.
9.
10.
The flameless atomic absorption procedure for determination of minute amount of mercury has been adapted for measuring thiol-groups in native and denatured proteins. The excess ofp-hydroxymercuribenzoate is removed by gel filtration after its reaction with the protein. The protein-p-hydroxymercuribenzoate complex is digested and the mercury is determined in an atomic absorption spectrophotometer. The sensitivity of the method allows measurement of 0.05 μg protein-bound mercury with the equipment used, but can be further increased. Results are presented for five different proteins.  相似文献   

11.
Flameless atomic absorption was used for direct measurements of calcium in microgram amounts of dried biological material. Sufficient analytical precision was reached with a commercial instrument complemented with a device allowing proper control of the heating of the graphite tube furnace. A comparison of different organs in the mouse revealed particularly high concentrations of calcium in the pancreatic islets. β cell-rich pancreatic islets from obob mice contained 60 mmol of calcium/kg dry weight. This value was reduced by 20 mmol during 120 min of washing in physiological saline. There was less calcium in the endocrine and exocrine parts of the directly excised pancreas than in samples incubated in Krebs-Ringer bicarbonate buffer. Islets microdissected from genetically diabetic mice were similar to those from nondiabetic controls with regard to the contents of both readily mobilizable and slowly exchangeable calcium.  相似文献   

12.
13.
14.
15.
Methods for the complete characterization of liposomes prepared by ether-injection are described in detail. The validity of atomic absorption spectrophotometry Ior measuring markers of trapped volume was checked by comparative determinations of markers with established optical spectrophotometrical methods. The favorable results usingl atomic absorption spectrophotometry to quantitate the marker Mn2+ are of particular relevance as manganese ion is also the paramagnetic probe in n.m.r, measurements of water permeability of lipo-somes; our results indicate that in such measurements no other marker need be incorporated.  相似文献   

16.
Human plasma, digested in a screw-capped Teflon vial for 1 h at 130 degrees C in concentrated nitric acid, is assayed for zinc by atomic absorption spectrophotometry using a single-slot, 10-cm burner and air/acetylene flame. The assay is linear to 10.00 mg Zn/liter, recovery averages 100.9%, and inter- and intraassay coefficients of variation are 5.9 and 1.9%. With this method, there is no burner clogging or adjustment necessary for sample viscosity. Sodium chloride does not interfere with the assay. The linear regression data of the standard curve for milligrams of Zn per liter (x) and milliabsorbance units (y) is y = 40x + 0.001.  相似文献   

17.
Atomic absorption spectroscopy was used for measuring the zinc content, in ppb (μg/1), of brain tissue. A new method for determining the correction factor of atomic absorption interference is described. Measurements of the zinc content of twenty-four regions of adult human brains showed the maximum zinc content in resistent sector and endplate of the Amnion's horn, corroborating the histochemical data. The distribution of zinc in other regions was relatively uniform, but white matter showed lower values than gray matter. The zinc content of seventeen regions of human newborn brains was below that in adult brains, for all regions. The blood content of brain tissue contributed only insignificantly to its zinc content.  相似文献   

18.
A method for the measurement of manganese in biological materials using long-path atomic absorption spectroscopy is described. Interference due to anions and cations is eliminated by performing the measurements in threequarter-saturated oxine (8-hydroxyquinoline). It is simple to perform and is sensitive over the range of 0.05–1.0 μg/ml. It does not require prior extraction with organic solvents or the use of the method of additions. The overall precision is excellent. The accuracy has been established using National Burean of Standards certified standards and by comparison with an emission spectrographic method.  相似文献   

19.
20.
An assay for cadmium in whole blood and urine using deuterium background-correction electrothermal atomic absorption spectroscopy (D(2)-ETAAS) was developed. Cadmium (in a 1- to 2-ml sample) was bound to 15 mg anion-exchange resin, interfering ions were removed in a 2-ml Bio-Spin column, and cadmium was extracted into 100 microl 1M nitric acid for analysis. Cadmium in the sample extract was concentrated 7-fold for blood and 10-fold for urine over the starting material. These steps produced cadmium atomic absorption traces with high signal to background ratios and allowed analysis against aqueous standards. At approximately 0.1 ng Cd/ml, mean intra- and interassay coefficients of variation were 11-12%. Cadmium recovery for 0.1 to 0.6 ng added cadmium was 107+/-4% for blood and 94+/-4% for urine (mean+/-SE, n=3). The mean detection limit (mean + 3 x SD of blank) was 0.008 ng/ml for blood and 0.003 ng/ml for urine. Samples from "unexposed" animals including humans ranged from 0.051+/-0.000 to 0.229+/-0.035 ng/ml. Values were approximately 10-fold lower than those obtained by the method of Stoeppler and Brandt using Zeeman background-correction ETAAS. This new high-sensitivity, low-volume assay will be useful for epidemiological studies, even those involving children, and will provide a means to help determine the contribution of cadmium to disease incidence in the general population.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏