首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A high-performance liquid chromatographic (HPLC) method with electrochemical detection and solid-phase extraction (SPE) using cartridges of weak cation-exchange capacity as the primary retention mechanism is described for the separation and determination of methylnaltrexone (MNTX) in small clinical samples of plasma or urine. The procedure was performed using a Phenomenex Prodigy ODS-2, 5 microm, 150x3.2 mm analytical column and 50 mM potassium acetate buffer, with 11% methanol as organic modifier at pH* 4.5 at a flow-rate of 0.5 ml/min. The detection potential was 700 mV. The six-point standard calibration curves were linear over three consecutive days in the range from 2 to 100 ng/ml. The average goodness of fit (r) was 0.9993. The lower limit of detection (LOD) and limit of quantification (LOQ) were found to be 2.0 and 5.0 ng/ml, respectively. At the LOQ, the coefficient of variation for the entire method was 8.0% and the accuracy was 10.0% (n = 10). Recovery of the drug from plasma was in the region of 94%. The method was applied to a pharmacokinetics study of methylnaltrexone after subcutaneous administration and in numerous assays of analytes in blood plasma and urine. The pharmacokinetics parameters for a single dose of 0.1 or 0.3 mg/kg in plasma were C(max) = 110 (+/-55) and 287 (+/-101) ng/ml and t(max) = 16.7 (+/-10.8) and 20.0 (+/-9.5) min, respectively. The method is simple, yet sensitive for the detection and determination of methylnaltrexone in biological samples at the level of the physiological response.  相似文献   

2.
Aplidine (dehydrodidemnin B) is a new marine-derived depsipeptide with a powerful cytotoxic activity, which is under early clinical investigation in Europe and in the US. In order to investigate the pharmacokinetic properties of this novel drug, an HPLC–tandem mass spectrometry method was developed for the determination of aplidine in biological samples. Didemnin B, a hydroxy analogue, was used as internal standard. After protein precipitation with acetonitrile and extraction with chloroform, aplidine was chromatographed with a RP octadecylsilica column using a water–acetonitrile linear gradient in the presence of formic acid at the flow-rate of 500 μl/min. The method was linear over a 5–100 ng/ml range (LOD=0.5 ng/ml) in plasma and over a 1.25–125 ng/ml range (LOD=0.2 ng/ml) in urine with precision and accuracy below 14.0%. The intra- and inter-day precision and accuracy were below 12.5%. The extraction procedure recoveries for aplidine and didemnin B were 69% and 68%, respectively in plasma and 91% and 87%, respectively in urine. Differences in linearity, LOQ, LOD and recoveries between plasma and urine samples seem to be matrix-dependent. The applicability of the method was tested by measuring aplidine in rat plasma and urine after intravenous treatment.  相似文献   

3.
An analytical method for the determination of letrozole (CGS 20 267) in plasma and of letrozole and its metabolite, CGP 44 645, in urine is described. Automated liquid-solid extraction of compounds from plasma and urine was performed on disposable 100-mg C8 columns using the ASPEC system. The separation was achieved on an ODS Hypersil C18 column using acetonitrile-phosphate buffer, pH 7, as the mobile phase at a flow-rate of 1.5 ml/min. A fluorescence detector was used for the quantitation. The excitation and emission wavelengths were 230 and 295 nm, respectively. The limits of quantitation (LOQ) of letrozole in plasma and in urine were 1.40 nmol/l (0.4 ng/ml) and 2.80 nmol/l, respectively. The respective mean recoveries and coefficient of variation (C.V.) were 96.5% (9.8%) in plasma and 104% (7.7%) in urine. The LOQ of CGP 44 645 in urine was 8.54 nmol/l (2 ng/ml). The mean recovery was 108% (6.3%). The compounds were well separated from co-extracted endogenous components and no interferences were observed at the retention times of compounds. The sensitivity of this method for letrozole in plasma should be sufficient for kinetic studies in humans with single doses of 0.5 mg and possibly less.  相似文献   

4.
Olanzapine is a commonly used atypical antipsychotic medication for which therapeutic drug monitoring has been proposed as clinically useful. A sensitive method was developed for the determination of olanzapine concentrations in plasma and urine by high-performance liquid chromatography with low-wavelength ultraviolet absorption detection (214 nm). A single-step liquid–liquid extraction procedure using heptane-iso-amyl alcohol (97.5:2.5 v/v) was employed to recover olanzapine and the internal standard (a 2-ethylated olanzapine derivative) from the biological matrices which were adjusted to pH 10 with 1 M carbonate buffer. Detector response was linear from 1–5000 ng (r2>0.98). The limit of detection of the assay (signal:noise=3:1) and the lower limit of quantitation were 0.75 ng and 1 ng/ml of olanzapine, respectively. Interday variation for olanzapine 50 ng/ml in plasma and urine was 5.2% and 7.1% (n=5), respectively, and 9.5 and 12.3% at 1 ng/ml (n=5). Intraday variation for olanzapine 50 ng/ml in plasma and urine was 8.1% and 9.6% (n=15), respectively, and 14.2 and 17.1% at 1 ng/ml (n=15). The recoveries of olanzapine (50 ng/ml) and the internal standard were 83±6 and 92±6% in plasma, respectively, and 79±7 and 89±7% in urine, respectively. Accuracy was 96% and 93% at 50 and 1 ng/ml, respectively. The applicability of the assay was demonstrated by determining plasma concentrations of olanzapine in a healthy male volunteer for 48 h following a single oral dose of 5 mg olanzapine. This method is suitable for studying olanzapine disposition in single or multiple-dose pharmacokinetic studies.  相似文献   

5.
An efficient method for the determination of atenolol in human plasma and urine was developed and validated. α-Hydroxymetoprolol, a compound with a similar polarity to atenolol, was used as the internal standard in the present high-performance liquid chromatographic analysis with fluorescence detection. The assay was validated for the concentration range of 2 to 5000 ng/ml in plasma and 1 to 20 μg.ml in urine. For both plasma and urine, the lower limit of detection was 1 ng/ml. The intra-day and inter-day variabilities for plasma samples at 40 and 900 ng/ml, and urine samples at 9.5 μg/ml were <3% (n=5).  相似文献   

6.
A sensitive and selective liquid chromatographic procedure using fluorimetric detection was developed to quantify dextromethorphan (DTM), 3-methoxymorphinan (3MM), dextrorphan (DT), 3-hydroxymorphinan (3OH) and two internal standards, codeine (COD) and ethylmorphine (ETM), in urine. Precision and accuracy of the assay were determined over a concentration range of 5–3200 ng/ml urine for DTM, 5–400 ng/ml urine for 3MM, 400–40 000 ng/ml urine for DT and 200–16 000 ng/ml urine for 3OH, by assaying freshly prepared calibration standards and replicates of six quality control (QC) samples on separate days. All of the inter-day and intra-day coefficients of variation (C.V.s) were less than 20% except for a low QC for 3MM. The inter-day and intra-day accuracies were less than 20% for the low QCs, less than 15% for the medium QCs and less than 12% for the high QCs, for all compounds. The limit of quantification (LOQ) was 2 ng/ml urine for DTM and 3MM, 250 ng/ml urine for DT, and 100 ng/ml urine for 3OH. Absolute recovery was 76% for DTM, 74% for 3MM, 77% for DT, 46% for 3OH, 73% for ETM, and 57% for COD. The frequency distribution of the CYP2D6 metabolic ratio (DTM/DT) illustrated a bimodal distribution whereas, the CYP3A metabolic ratio (DTM/3MM) exhibited a unimodal distribution in overnight urine samples of volunteers who ingested 30 mg dextromethorphan hydrobromide. The CYP2D6 metabolic ratio significantly correlated with 3MM/3OH (r=0.82) and DTM/3OH (r=0.95) but did not correlate with the CYP3A metabolic ratio (r=0.27).  相似文献   

7.
A high-performance liquid chromatographic method for the measurement of bumetamide in plasma and urine is described. Following precipitation of proteins with acetonitrile, bumetanide was extracted from plasma or urine on a 1-ml bonded-phase C18 column and eluted with acetonitrile. Piretanide dissolved in methanol was used as the internal standard. A C18 Radial Pak column and fluorescence detection (excitation wavelength 228 nm; emission wavelength 418 nm) were used. The mobile phase consisted of methanol—water—glacial acetic acid (66:34:1, v/v) delivered isocratically at a flow-rate of 1.2 ml/min. The lower limit of detection for this method was 5 ng/ml using 0.2 ml of plasma or urine. Nafcillin, but not other semi-synthetic penicillins, was the only commonly used drug that interfered with this assay. No interference from endogenous compounds was detected. For plasma, the inter-assay coefficients of variation of the method were 7.6 and 4.4% for samples containing 10 and 250 ng/ml bumetanide, respectively. The inter-assay coefficients of variation for urine samples containing 10 and 2000 ng/ml were 8.1 and 5.7%, respectively. The calibration curve was linear over the range 5–2000 ng/ml.  相似文献   

8.
We have established a highly sensitive high-performance liquid chromatographic method for the determination of an anticancer drug, UCN-01, in human plasma or urine. Using a fluorescence detector set at an excitation wavelength of 310 nm and emission monitored at 410 nm, there was a good linearity for UCN-01 in human plasma (r=0.999) or urine (r=0.999) at concentrations ranging from 0.2 to 100 ng/ml or 1 to 400 ng/ml, respectively. For intra-day assay, in plasma samples, the precision and accuracy were 1.8% to 5.6% and −10.0% to 5.2%, respectively. For inter-day assay, the precision and accuracy were 2.0% to 18.2% and 2.4% to 10.0%, respectively. In urine samples, the intra- and inter-day precision and accuracy were within 3.9% and ±2.7%, respectively. The lower limit of quantification (LLOQ) was set at 0.2 ng/ml in plasma and 1 ng/ml in urine. UCN-01 in plasma samples was stable up to two weeks at −80°C and also up to four weeks in urine samples. This method could be very useful for studying the human pharmacokinetics of UCN-01.  相似文献   

9.
A rapid, reliable and specific reversed-phase high-performance liquid chromatographic procedure is described for the determination of diphenylpyraline hydrochloride at nanogram concentrations in plasma and urine. After extraction of the drug with n-pentane-2-propanol (50:1) from alkalinized samples, the organic extract was evaporated to dryness, reconstituted with methanol and chromatographed using a 5-μm Asahipak ODP-50 C18 column with UV detection at 254 nm. The elution time for diphenylpyraline was 7.9 min. The overall recovery of diphenylpyraline from spiked plasma and urine samples at concentrations ranging from 53 to 740 ng/ml were 94.65% and 92.29%, respectively. Linearity and precision data for plasma and urine standards after extraction were acceptable. The limit of detection was 15 ng/ml for both plasma and urine samples at 0.002 AUFS.  相似文献   

10.
A sensitive high-performance liquid chromatographic (HPLC) method with ultraviolet absorption detection (292 nm) was developed and validated for the determination of the new phosphodiesterase V inhibitor, DA-8159 (DA), in human plasma and urine. A single step liquid-liquid extraction procedure using ethyl ether was performed to recover DA and the internal standard (sildenafil citrate) from 1.0 ml of biological matrices combined with 200 microl of 0.1M sodium carbonate buffer. A Capcell Pak C18 UG120 column (150 mm x 4.6 mm I.D., 5 microm) was used as a stationary phase and the mobile phase consisted of 30% acetonitrile and 70% 20mM potassium phosphate buffer (pH 4.5) at a flow rate of 1.0 ml/min. The lower limit for quantification was 5 ng/ml for plasma and 10 ng/ml for urine samples. Within- and between-run accuracy and precision were < or =15 and < or =10%, respectively, in both plasma and urine samples. The recovery of DA from human plasma and urine was greater than 70%. Separate stability studies showed that DA is stable under the conditions of analysis. This validated assay was used for the pharmacokinetic analysis of DA during a phase I, rising dose study.  相似文献   

11.
A reversed-phase liquid chromatography method involving pre-column derivatisation with fluorescein isothiocyanate (FITC, isomer I) for determination of tobramycin in urine samples after inhalation has been developed. FITC reacts with the primary amino groups of tobramycin and other aminoglycosides under mild conditions to form a highly fluorescent and stable derivative. The chromatographic separation was carried out on a Phenomenex Luna C(18) column at ambient temperature using a constant flow rate of 1 ml/min and mobile phase of acetonitrile-methanol-glacial acetic acid-water (420:60:5:515, v/v/v/v). The tobramycin-FITC derivative was monitored by fluorescent detection at an excitation wavelength 490 nm and emission wavelength 518 nm. The linearity of response for tobramycin was demonstrated at 11 different concentrations of tobramycin extracted from spiked urine, ranging from 0.25 to 20 microg/ml. Tobramycin and neomycin were extracted from spiked urine by a solid phase extraction clean-up procedure on a carboxypropyl-bonded phase (CBA) weak cation-exchange cartridge, and the relative recovery was >99% (n=5). The limit of detection (LOD) and limit of quantitation (LOQ) in urine were 70 and 250 ng/ml, respectively. The method had an accuracy of <0.2%, and intra-day and inter-day precision (in term of %coefficient of variation) were <4.89% and 8.25%, respectively. This assay was used for urinary pharmacokinetic studies to identify the relative lung deposition of tobramycin post-inhalation of tobramycin inhaled solution 300 mg/5 ml (TOBI) by different nebuliser systems.  相似文献   

12.
Concentrations of mono(2-ethylhexyl)phthalate (MEHP), and di(2-ethylhexyl)phthalate (DEHP), in serum of healthy volunteers were determined by high performance liquid chromatography (HPLC) with tandem mass spectrometry (LC/MS/MS). The serum was extracted with acetone, followed by hexane extraction under acidic conditions, and then applied to the LC/MS/MS. Recoveries of 20 ng/ml of MEHP and DEHP were 101+/-5.7 (n=6) and 102+/-6.5% (n=6), respectively. The limits of quantification (LOQ) of MEHP and DEHP in the method were 5.0 and 14.0 ng/ml, respectively. The concentration of MEHP in the serum was at or less than the LOQ. The concentration of DEHP in the serum was less than the LOQ. Contaminations of MEHP and DEHP from experimental reagents, apparatus and air during the procedure were less than the LOQ and were estimated to be <1.0 and 2.2+/-0.6 ng/ml, respectively. After subtraction of the contamination, the net concentrations of MEHP and DEHP in the serum were estimated at or <5 and <2 ng/ml, respectively. To decrease contamination by DEHP, the cleanup steps and the apparatus and solvent usage were minimized in the sample preparation procedures. The high selectivity of LC/MS/MS is the key for obtaining reliable experimental data from in the matrix-rich analytical samples and for maintaining a low level contamination of MEHP and DEHP in this experimental system. This method would be a useful tool for the detection of MEHP and DEHP in serum.  相似文献   

13.
Caffeic acid phenethyl ester (CAPE) is one of the most bioactive compounds of propolis, a resinous substance collected and elaborated by honeybees. A new liquid chromatography-electrospray ionisation tandem mass spectrometric method was developed and validated for its determination in rat plasma and urine, using taxifolin as internal standard. After sample preparation by liquid/liquid extraction with ethyl acetate, chromatographic separations were carried out with an ODS-RP column using a binary mobile phase gradient of acetonitrile in water. Detection was performed using a turboionspray source operated in negative ion mode and by multiple reaction monitoring. The method was validated, showing good selectivity, sensitivity (LOD = 1 ng/ml), linearity (5-1000 ng/ml; r > or = 0.9968), intra- and inter-batch precision and accuracy (< or =14.5%), and recoveries (94-106%) in both plasma and urine. Stability assays have shown that CAPE is rapidly hydrolysed by plasmatic esterases, which are however inhibited by sodium fluoride. The method was applied to the determination of CAPE levels in rat plasma and urine after oral administration, showing that CAPE is rapidly absorbed and excreted in urine both as unmodified molecule and as glucuronide conjugate.  相似文献   

14.
Sensitive and specific high-performance liquid chromatographic methods with fluorescence detection are described for the determination of the metabolites of mox sylyte (4-(2-dimethylaminoethoxy)-5-isopropyl-2-methylphenyl acetate) in human plasma and urine. Deacetylmoxisylyte glucuroconjugate (DAM-G) was hydrolysed enzymatically using β-glucuronidase and quantified as the difference between the DAM concentrations determined after and before hydrolysis. The two sulphate derivatives (deacetylmoxisy;yte sulphoconjugate, DAM-S and monomethyldeacetylmoxisylyte sulphoconjugate, MDAM-S), were analysed without prior hydrolysis. Their extraction from plasma and urine, as well as that of DAM from plasma, involved the use of C18 cartridges adapted on a Benchmate workstation. DAM in urine was quantified after liquid-liquid extraction. The two methods were validated for specificity, linearity, intra- and inter-day precision and accuracy. Precision was generally ≤15% and accuracy ≤12%. In plasma, the limits of quantification were 2.5 ng/ml for DAM and 2.8 ng/ml for the two sulphates; in urine, they were 40 ng/ml for DAM and 200 ng/ml for the sulphates. These methods were used for pharmacokinetic studies in healthy subjects.  相似文献   

15.
A reliable and sensitive method was developed for determination of thymol in human plasma by automated headspace solid-phase microextraction (SPME). After enzymatic cleavage of thymol sulfate thymol was extracted by a 65 microm polydimethylsiloxane-divinylbenzene crimped fiber (Supelco) after addition of sodium chloride and phosphoric acid (85%). Desorption of the fiber was performed in the injection port of a gas chromatograph at 220 degrees C (HP 5890; 50 m x 0.2 mm I.D., 0.2 microm HP Innowax capillary column; flame ionization detection). Fibers were used repeatedly up to 40 analysis. The recovery was 5% after 35 min of extraction. The calibration curve was linear in the range of 8.1-203.5 ng ml(-1) with a limit of quantitation (LOQ) of 8.1 ng ml(-1). The within-day and between-day precision and accuracy were < or = 20% at the LOQ and <15% at higher concentrations according to international guidelines for validation of bioanalytical methods. After administration of a thymol-containing herbal extract only thymol sulfate, no free thymol, could be detected in human plasma, thus analysis of thymol was after enzymatic cleavage of thymol sulfate. It is concluded that the newly developed automated method can be used in clinical trials on bioavailability and pharmacokinetics of thymol-containing herbal medicinal products.  相似文献   

16.
A sensitive and selective high-performance liquid chromatographic (HPLC) method was developed for the determination of pramipexole in human plasma and urine. Plasma/urine is made alkaline before pramipexole and BHT-920 (internal standard) are extracted by ethyl ether and back-extracted with a solution that contains heptanesulfonic acid. Separation is achieved by ion-pair chromatography on a Zorbax Rx C8 column with electrochemical detection at 0.6 V for plasma and ultraviolet detection at 286 nm for urine. The retention times of pramipexole and internal standard are approximately 14.4 and 10.7 min, respectively. The assay is linear in concentration ranges of 50 to 15 000 pg/ml (plasma) and 10 to 10 000 ng/ml (urine). The correlation coefficients are greater than 0.9992 for all curves. For the plasma method, the analysis of pooled quality controls (300, 3000, and 10 000 pg/ml) demonstrates excellent precision with relative standard deviations (R.S.D.) (n=18) of 1.1%, 2.3%, and 6.8%, respectively. For the urine method, quality control pools prepared at 30, 300, and 3000 ng/ml had R.S.D. values (n=18) of 2.9%, 1.7%, and 3.0%, respectively. The plasma and urine controls were stable for more than nine and three months, respectively. The mean recoveries for pramipexole and internal standard from plasma were 97.7% and 98.2%, respectively. The mean recoveries for pramipexole and internal standard from urine were 89.8% and 95.1%, respectively. The method is accurate with all intra-day (n=6) and overall (n=18) mean values for the quality control samples being less than 6.4 and 5.8% from theoretical for plasma and urine, respectively.  相似文献   

17.
A method is proposed for the determination of nicotine and cotinine in human urine, plasma and saliva. Nicotine and cotinine were extracted from alkalinized sample with ethyl ether and concentrated to minimum volume with nitrogen stream. The volatility of nicotine was prevented by the addition of acetic acid to the organic solvent during evaporation. Peak shapes and quantitation of nicotine and cotinine are excellent, with linear calibration curves over a wide range of 1-10,000 ng/ml. The detection limits of nicotine and cotinine are 0.2 ng/ml in urine and 1.0 ng/ml in plasma and saliva. The intra-day precision of nicotine and cotinine in all samples was <5% relative standard deviation (RSD). Urine, plasma and saliva samples of 303 non-smoking and 41 smoking volunteers from a girl's high school in Korea were quantified by the described procedure. As a result, the concentrations of nicotine and cotinine in plasma ranged from 6 to 498 ng/ml and 4 to 96 ng/ml. Otherwise, those of nicotine and cotinine in saliva ranged from 0 to 207 ng/ml and 0 to 42 ng/ml, and those of nicotine and cotinine in urine ranged from 0 to 1,590 ng/ml and 0 to 2,986 ng/ml, respectively. We found that the concentration of cotinine in plasma was successfully predicted from the salivary cotinine concentration by the equation y=2.31x+4.76 (x=the concentration of cotinine in saliva, y=the concentration of cotinine in plasma). The results show that through the accurate determination of cotinine in saliva, the risk of ETS-exposed human can be predicted.  相似文献   

18.
A sensitive capillary electrophoretic method for the determination of carvedilol enantiomers in 100 μl of human plasma has been developed and validated. Carvedilol and the internal standard carazolol are isolated from plasma samples by liquid–liquid extraction using diethylether. A sensitive and selective detection is provided by helium–cadmium laser-induced fluorescence. The total analysis time is 17.5 min, about 30 min are needed for the sample preparation. The linearity of the assay ranges from 1.56 to 50 ng/ml per carvedilol enantiomer. The limits of quantification (LOQ) for the carvedilol enantiomers in 100 μl of human plasma are 1.56 ng/ml. The inter-day accuracy for R-carvedilol is between 95.8 and 103% (104% at LOQ) and for S-carvedilol between 97.1 and 103% (107% at LOQ); the inter-day precision values are between 3.81 and 8.64% (10.9% at LOQ) and between 5.47 and 7.86% (7.91% at LOQ) for R- and S-carvedilol, respectively. The small sample volume needed is especially advantageous for the application in clinical studies in pediatric patients. As an application of the assay concentration/time profiles of the carvedilol enantiomers in a 5-year-old patient receiving a test dose of 0.09 mg/kg carvedilol are reported.  相似文献   

19.
Methods for the measurement of penicillin concentration in bovine plasma, kidney and urine were developed and validated. Detection was based on liquid chromatography/tandem mass spectrometry (LC/MS/MS). Phenethecillin was used as an internal standard. Plasma was extracted with acetonitrile using a method with a calculated limit of quantitation (LOQ) of 12 ng/mL. Kidney samples were homogenized in water and acetonitrile, then cleaned up on C18-bonded silica SPE cartridges. The LOQ of this procedure was 10 ng/g. Urine samples were diluted, filtered, and analyzed directly. The LOQ of this procedure was 63 ng/mL. The overall accuracy for plasma was 103% with coefficient of variation (CV) of 3%; for kidney, 96% and 11%, respectively, and for urine, 98% and 4%, respectively. These methods were applied to the analysis of plasma, urine, and kidney biopsy samples taken from standing animals that had been dosed with penicillin.  相似文献   

20.
An HPLC system using solid-phase extraction and HPLC with UV detection has been validated in order to determine tramadol and o-desmethyltramadol (M1) concentrations in human plasma. The method developed was selective and linear for concentrations ranging from 50 to 3500 ng/ml (tramadol) and 50 to 500 ng/ml (M1) with mean recoveries of 94.36±12.53% and 93.52±7.88%, respectively. Limit of quantitation (LOQ) was 50 ng/ml. For tramadol, the intra-day accuracy ranged from 95.48 to 114.64% and the inter-day accuracy, 97.21 to 103.24%. Good precision (0.51 and 18.32% for intra- and inter-day, respectively) was obtained at LOQ. The system has been applied to determine tramadol concentrations in human plasma samples for a pharmacokinetic study.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号