首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 531 毫秒
1.
Background Two novel approaches to implanting a central venous catheter port in non‐human primates (NHPs) using peripheral insertion are presented and compared. Methods Sixty vascular access port (VAP) implants were attempted in 52 NHPs by saphenous vein puncture (n = 20) or saphenous vein cutdown (n = 40). Results Fifty eight procedures were successful. Eighteen of 20 VAPs were successfully placed using saphenous vein puncture, and 40 of 40 using saphenous vein cutdown. There were no significant differences between procedures. Mean implantation times were similar between groups. At explant or study endpoint, all 58 VAPs were patent. Conclusions Vascular access port implantation by saphenous vein puncture or saphenous vein cutdown is safe and effective in NHPs. It is less invasive than conventional procedures, has fewer complications, provides outstanding patency, and reduces surgery time. Furthermore, it allows for cooperative in‐homecage VAP use, minimizing handling stress. We recommend these refined methods for long‐term vascular access in NHPs.  相似文献   

2.
BACKGROUND: Totally implantable venous access devices are widely used for infusion of chemotherapy or parenteral nutrition. Device associated complications include technical operative problems, infections, paravasal infusions and catheter or punction chamber dislocation. CASE PRESENTATION: We present the case of a 49-year-old patient with the rare complication of a intrapulmonal catheter dislocation of a totally implantable venous access system. Treosulfane for chemotherapy of metastatic breast cancer was infused via the catheter causing instant coughing and dyspnoea which lead to the diagnosis of catheter dislocation. The intrapulmonal part of the catheter was removed under thoracoscopic control without further complications. CONCLUSION: Intrapulmonal catheter dislocation is a rare complication of a totally implantable venous access device which can not be avoided by any prophylactic measures. Therefore, the infusion system should be tested before each use and each new symptom, even when not obviously related to the catheter should be carefully documented and evaluated by expert physicians to avoid severe catheter-associated complications.  相似文献   

3.
The vascularization of the telencephalic choroid plexus of the sterlet Acipenser ruthenus, a ganoid fish, was examined by vascular corrosion casting and by light and transmission electron microscopy. The arterial supply is from the dorsal mesencephalic artery via: 1) the ventral choroidal arteries (left and right); 2) the dorsal choroidal arteries (left and right); 3) the caudal choroidal arteries (left and right); 4) the ventral arteries of the dorsal sac; and, from the olfactory arteries, via 5) the rostral choroidal arteries. The venous drainage is mainly through a single main choroidal vein that can take various courses either directly to the anterior cardinal vein or via the middle cerebral vein to the anterior cardinal vein. To a lesser extent, the plexus is drained via the lateral telencephalic veins and the ventral vein of the dorsal sac to the middle cerebral vein. By angioarchitecture and form, the plexus can be subdivided into five distinct parts: the surface network, the median folds, the large lateral folds, the small lateral folds, and the area common to the bottom of the dorsal sac and the telencephalic plexus. Diameters of terminal vessels as measured from vascular corrosion casts and from paraplast, semithin, and ultrathin sections were never less than 10 micron. It is suggested that the different areas in one plexus may have different functions with respect to secretion and absorption of cerebrospinal fluid.  相似文献   

4.
Implantation of resynchronization implantable cardioverter defibrillator was performed in a patient with persistent left superior vena cava. A dual coil defibrillation lead was inserted in the right ventricle apex via a small innominate vein. Left ventricular and atrial leads were implanted through persistent left superior vena cava. Left ventricular lead was easily implanted into the postero lateral vein. Pacing thresholds and sensing values were excellent and remained stable at 18 months follow-up.Presence of persistent left superior vena cava generally makes transvenous lead implantation difficult. However when a favorable coronary sinus anatomy is also present, it may facilitate left ventricular lead positioning in the coronary sinus branches.  相似文献   

5.

Background

Right internal jugular vein (IJV) is a preferred access route for tunneled (cuffed) dialysis catheters (TDCs), and both right external jugular vein (EJV) and left IJV are alternative routes for patients in case the right IJV isn’t available for TDC placement. This retrospective study aimed to determine if a disparity exists between the two alternative routes in hemodialysis patients in terms of outcomes of TDCs.

Methods

49 hemodialysis patients who required TDCs through right EJV (n = 21) or left IJV (n = 28) as long-term vascular access were included in this study. The primary end point was cumulative catheter patency. Secondary end points include primary catheter patency, proportion of patients that never required urokinase and incidence of catheter-related bloodstream infections (CRBSI).

Results

A total of 20,870 catheter-days were evaluated and the median was 384 (interquartile range, 262–605) catheter-days. Fewer catheters were removed in the right EJV group than in the left IJV group (P = 0.007). Mean cumulative catheter patency was higher in the right EJV group compared with the left IJV group (P = 0.031). There was no significant difference between the two groups in the incidence of CRBSI, primary catheter patency or proportion of patients that never required urokinase use. Total indwell time of antecedent catheters was identified as an independent risk factor for cumulative catheter patency by Cox regression hazards test with an HR of 2.212 (95% CI, 1.363–3.588; p = 0.001).

Conclusions

Right EJV might be superior to left IJV as an alternative insertion route for TDC placement in hemodialysis patients whose right IJVs are unavailable.  相似文献   

6.
A 52-year-old woman suffering from breast cancer had a port-a-cath implanted to administer chemotherapy. A port-a-cath (a portmanteau of portal and catheter) consists of a reservoir compartment (the portal) which has a silicone bubble for needle insertion (the septum) mounted to the catheter. Six and a half months after implantation, she complained of palpitations. An ECG showed sinus rhythm with premature atrial complexes. An X-ray showed dislocation of the distal tip of the catheter with migration into the right atrium (RA) and right ventricle (RV).  相似文献   

7.
Ablation of cavotricuspid isthmus flutter and atrial tachycardia in a complex substrate has never been reported using remote navigation via superior approach. Venous access was obtained via right internal jugular for ablation and left subclavian for duodecapolar catheter placement into the coronary sinus. In a posttransplant patient presenting with both regular and irregular tachycardia, both cavotricuspid isthmus flutter in the donor and atrial tachycardia in the recipient was mapped using a two catheter approach. Successful ablation of typical atrial flutter and anastomotic block was achieved. This is the first report of successful ablation of cavotricuspid isthmus flutter and posttransplant atrial tachycardia using magnetic navigation via superior approach. Using only two catheters, this approach is logical and feasible in complex substrates with interrupted inferior venous access.  相似文献   

8.
A 70-year-old woman with symptomatic Mobitz type II atrioventricular block underwent implantation of a dual-chamber pacemaker 11 years ago. The leads were inserted through a percutaneous puncture of the right subclavian vein, using standard techniques. Both leads were passive fixation leads. Due to battery failure and end of life criteria, the pulse generator (PG) had been routinely replaced six years previously. Predischarge pacemaker control revealed normal pacing, sensing thresholds and impedance for both leads. Because of a syncopal attack subsequent to lead fractures, most likely secondary to right subclavian crush syndrome (SCS) of both leads, she underwent a double lead re-implantation one year after PG replacement by access via left subclavian vein puncture.After a symptom-free period of few years she was re-analysed because of palpitations, dizziness, angina pectoris and tiredness. Pulmonary embolisation and myocardial perfusion defects were detected utilising scintigraphic techniques. Chest X-ray revealed the crushed atrial lead dislocated from the right subclavian region and lodged into the right ventricle towards the inferior septum. Because she was symptomatic, a retrieval technique was applied and the crushed atrial lead was pulled back from the right ventricle and securely fixed to its former position. On maintenance medical treatment, she remains well.  相似文献   

9.
Background: Pulmonary vein isolation (PVI) is an established treatment for atrial fibrillation (AF). During PVI an electrical conduction block between pulmonary vein (PV) and left atrium (LA) is created. This conduction block prevents AF, which is triggered by irregular electric activity originating from the PV. However, transmural atrial lesions are required which can be challenging. Re-conduction and AF recurrence occur in 20 - 40% of the cases. Robotic catheter systems aim to improve catheter steerability. Here, a procedure with a new remote catheter system (RCS), is presented. Objective of this article is to show feasibility of robotic AF ablation with a novel system. Materials and Methods: After interatrial trans-septal puncture is performed using a long sheath and needle under fluoroscopic guidance. The needle is removed and a guide wire is placed in the left superior PV. Then an ablation catheter is positioned in the LA, using the sheath and wire as guide to the LA. LA angiography is performed over the sheath. A circular mapping catheter is positioned via the long sheath into the LA and a three-dimensional (3-D) anatomical reconstruction of the LA is performed. The handle of the ablation catheter is positioned in the robotic arm of the Amigo system and the ablation procedure begins. During the ablation procedure, the operator manipulates the ablation catheter via the robotic arm with the use of a remote control. The ablation is performed by creating point-by-point lesions around the left and right PV ostia. Contact force is measured at the catheter tip to provide feedback of catheter-tissue contact. Conduction block is confirmed by recording the PV potentials on the circular mapping catheter and by pacing maneuvers. The operator stays out of the radiationfield during ablation. Conclusion: The novel catheter system allows ablation with high stability on low operator fluoroscopy exposure.  相似文献   

10.
Cell delivery via the retrograde coronary route boasts less vessel embolism, myocardial injury, and arrhythmogenicity when compared with those via antegrade coronary administration or myocardial injection. However, conventional insertion into the coronary sinus and consequent bleeding complication prevent its application in small animals. To overcome the complication of bleeding, we described a modified coronary retroinfusion technique via the jugular vein route in rats with myocardial infarction (MI). A flexible wire with a bent end was inserted into the left internal jugular vein and advanced slowly along the left superior vena cava. Under direct vision, the wire was run into the left cardiac vein by rotating the wire and changing the position of its tip. A fine tube was then advanced along the wire to the left cardiac vein. This modified technique showed less lethal hemorrhage than the conventional technique. Retroinfusion via transjugular catheter enabled efficient fluid or cell dissemination to the majority areas of the free wall of the left ventricle, covering the infarcted anterior wall. In conclusion, transjugular cardiac vein catheterization may make retrocoronary infusion a more safe and practical route for delivering cell, drug, and gene therapy into the infarcted myocardium of rats.  相似文献   

11.
A nonhuman primate model comprising adult male rhesus monkeys (Macaca mulatta) with chronically indwelling subcutaneous central venous access devices provides a unique opportunity to determine plasma pharmacokinetics of new drugs such as anticancer and anti- retroviral agents. The central venous access we use is a low-profile, single-septum, titanium port that is attached to a radiopaque, indwelling catheter; the catheter is implanted in an internal jugular vein. A common complication following placement of the venous access device was migration of the catheter tip. We therefore modified the standard procedure by cutting the silicone catheter and introducing the rigid connector to secure the catheter to the vessel at the insertion site (approximately 9 to 13 cm from the distal end of the catheter). Prior to the use of the connector, three of five catheters migrated within 4 weeks after placement. In contrast, all 13 internal jugular catheters with connectors have remained patent without migration of the catheter tip. Therefore, incorporation of the catheter connector appears to have eliminated the problem of catheter migration.  相似文献   

12.
A 69-year-old woman with palpitations was referred to our hospital for a second session of atrial fibrillation (AF) catheter ablation. She had a history of AF ablation including pulmonary vein (PV) isolation and persistent left superior vena cava (PLSVC) isolation. Electrophysiologic studies showed the veno-atrial connections that had recovered. After PV isolation was performed, AF was induced by atrial premature contraction (APC) from the PLSVC, and AF storm occurred. During PLSVC isolation, AF was not induced by APC from the PLSVC. PLSVC isolation continued during sinus rhythm. The elimination of the PLSVC potential was difficult to confirm because of the far-field potential of the left ventricle. Then, we performed right ventricular pacing. The remaining PLSVC potential was identified. After that, the PLSVC isolation was successful during right ventricular pacing. Complications were not observed. The patient had no recurrence of AF thereafter.  相似文献   

13.
A summary of the work in synchronous assisted circulation undertaken at the Tufts-New England Medical Center Hospitals for the past year is presented.Counterpulsation, introduced in 1958, reduces myocardial oxygen consumption and increases coronary flow. It was applied to seven patients with terminal cardiogenic shock: one patient survived and three showed temporary improvement.The synchronous external assist makes possible control of the blood volume distribution, increases the cardiac output and decreases the pressure work of the left ventricle. The procedure does not require cannulation of the vascular system and is atraumatic.The same concept has been applied to the right ventricle using synchronous respiration.An “in-series” subcutaneously exteriorized prosthetic left ventricle, capable of long-term left ventricular assist, is under development. The device can atrialize the left ventricle. It requires no intracorporeal source of energy.This program offers hope for the development of effective temporary and long-term circulatory-assist procedures.  相似文献   

14.
A 46-year-old Brugada syndrome patient underwent insertion of a dual-chamber implantable cardioverter- defibrillator (ICD), revealing a left-sided superior vena cava (SVC), (figure 1), running, characteristically, left from the sternum and flowing into the great cardiac vein. Following this course, the atrial lead was placed in the right atrium (RA) (figure 2, arrow, note dorsal position). The ventricular lead was inserted through the connecting anonymous vein between left and right SVC (figure 1, double arrow), into the right SVC and right ventricle (RV). The presence of a left superior vena cava results from the persistence of the embryonic left anterior cardinal vein. This anomaly is present in approximately 0.5% of the general population and in 3 to 5% of persons with other congenital heart defects, as established by autopsy.  相似文献   

15.
Transvenous endocardial pacing through classical implantation of a pace/sensing lead in the right ventricle is strictly contraindicated in patients with a mechanical tricuspid valve. Usually permanent pacing is achieved by an epimyocardial surgical approach. We hereby describe the implantation of a single site left ventricle pacing lead in the anterior interventricular vein in a 60 year-old woman with symptomatic bradycardia, permanent atrial fibrillation, and mechanical tricuspid valve. The described use of left ventricle pacing through a coronary vein lead, in a patient with favorable venous anatomy, provided (through a minimal invasive approach) effective with a low and stable threshold.  相似文献   

16.
Although rabbit ear vessels are readily accessible, the veins can collapse and thrombose after multiple venipunctures, and the artery may undergo vasospasm when repeatedly catheterized. Twenty-two male and female New Zealand White rabbits were cannulated with the catheter tip located in the jugular vein. The mean life of the port was noted to be approximately 3.5 months, with ranges of 3 days to 10 months. With proper maintenance and care, vascular access ports are a useful alternative to multiple venipuncture for long-term studies, thereby sparing marginal and central vessels and minimizing stress to both animals and investigators.  相似文献   

17.
Diabetes mellitus is associated with a high incidence and poor prognosis of cardiovascular disease. The aim of the present study was to examine the effect of relatively short-term (5 weeks) Type I diabetes on the left ventricle, the right ventricle and the vessel (vein) on the left ventricle of the myocardium at molecular level by FTIR (Fourier-transform infrared) microspectroscopy. The rats were categorized into two groups: control group (for the left ventricle myocardium, n=8; for the right ventricle myocardium, n=9; for the vein, n=9) and streptozotocin-induced diabetic group (for the left ventricle myocardium, n=7; for the right ventricle myocardium, n=9; for the vein, n=8). Two adjacent cross-sections of 9 microm thickness were taken from the ventricles of the hearts in two groups of rats by using a cryotome. The first sections were used for FTIR microspectroscopy measurements. The second serial sections were stained by haematoxylin/eosin for comparative purposes. Diabetes caused an increase in the content of lipids, an alteration in protein profile with a decrease in alpha-helix and an increase in beta-sheet structure as well as an increase in glycogen and glycolipid contents in both ventricles and the vein. Additionally, the collagen content was found to be increased in the vein of the diabetic group. The present study demonstrated that diabetes-induced alterations in the rat heart can be detected by correlating the IR spectral changes with biochemical profiles in detail. The present study for the first time demonstrated the diabetes-induced alterations at molecular level in both ventricle myocardia and the veins in relatively short-term diabetes.  相似文献   

18.
Cardiac tumors are rarely observed. The incidence of primary cardiac tumors in autopsy series ranges from 0.0017% to 0.19%. Surgical resection is the main therapy for the majority of the cardiac tumors. Surgical treatment of these tumors carries an operative mortality rate of 3% or less. In this article, we present our experience with a female patient, who had a right sided atrial tumor mimicking a myxoma. Port access surgery was performed through a small right sided "key-hole" working port in the fourth intercostal space. Extracorporeal circulation was conducted by femoro-femoral bypass and a kinetic assisted venous drainage system. Although, the safety and efficacy of port access approach have been well documented for resection of left atrial tumors in some series, use of this technique for right atrial tumor resection can be detrimental.  相似文献   

19.
The goal of the present study was to develop a competitive PCR assay to measure changes in the expression of endothelial nitric oxide synthase (eNOS) mRNA levels throughout the canine vascular tree. A partial sequence of canine eNOS cDNA (1.86 kb), inducible NOS (1.95 kb), and neuronal NOS (1.16 kb) was cultured from canine aortic endothelial cells, LPS-treated canine splenic vein endothelial cells, and from canine left ventricle, respectively. Competitor eNOS cDNA (eNOS-C) was constructed via recombinant PCR. Thus, with the use of a standard curve competitive PCR with eNOS-C, the amount of eNOS mRNA in 500 ng of total RNA was greatest in the circumflex > right coronary artery > left anterior descending coronary artery > aorta. The isolation of coronary microvessels from the left ventricle was associated with an enrichment of endothelial cell markers such as eNOS, von Willebrand factor, and caveolin-1, an observation supported by the detection of up to 15-fold higher levels of eNOS mRNA in coronary microvessels relative to the larger arteries. The ability to quantify changes in eNOS mRNA levels throughout the canine vasculature should provide greater insight into the molecular mechanisms of how this gene is regulated in physiological and pathophysiological states.  相似文献   

20.
Structural and functional changes of pulmonary circulation related to pathophysiology of pulmonary arterial hypertension (PAH) remain to be fully elucidated. Angiographic visualization in in vivo animals provided a powerful tool for assessing the major indexes associated with the pathogenesis of PAH. In this study, we have exploited the full potential of synchrotron radiation (SR) microangiography to show the ability to visualize pulmonary hemodynamics in a closed-chest mouse. Male adult mice were anesthetized and cannulated with a customized 24-gauge catheter into the right ventricle via the jugular vein for administering iodine contrast agent. The microangiography was performed on the left lung. We measured dynamic changes in vessel diameter in response to acetylcholine (ACh) and acute exposure to hypoxic gas (10% O(2)). Moreover, the pulmonary transit time was estimated by the time of contrast agent circulating. We were able to visualize the pulmonary arteries from the left pulmonary artery (LPA) to the third generation of branching (inner diameter <100 μm). ACh and acute hypoxia induced vascular responses chiefly in the second and third branching vessels rather than the LPA and the first branching vessels. The transit time was only 0.83 s. These results demonstrate the effectiveness of SR for visualizing the pulmonary circulation in a closed-chest mouse. Future studies using SR microangiography on specific gene-targeted knockout and transgenic mice will provide new insights into the pathophysiology of pulmonary dysfunction and functional adaptation to survive in hypoxic condition.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号