首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A previously healthy 63-year-old woman with multiple risk factors for coronary artery disease was referred to the outpatient clinic with a three-month history of atypical chest pain. At physical examination no abnormalities could be detected and the ECG was completely normal. At transthoracic echocardiography and transoesophageal echocardiography a mass, 1 cm in diameter and attached to the right coronary cusp of the aortic valve, was detected. The mass had the echocardiographic appearance of a nonhomogeneous, round, dense, mobile structure, typical features of a fibroelastoma (figure 1). On dipyridamole-thallium scintigraphy, no coronary insufficiency could be demonstrated. Since cardiac papillary fibroelastomas are associated with a risk of thromboembolic events, the patient underwent complete tumour excision by a simple shave excision (figure 2).  相似文献   

2.
To examine the value of the combined approach of transthoracic and transesophageal 2D-echocardiography in diagnosis of heart tumors this study was performed on 30 patients (11 males, 19 females, age 15 to 82 years) with atrial (n = 17) and pericardial (n = 13) tumors. Echocardiography was performed using an electronic sector scanner (Varian 3400 R) and a 2.25 MHz transducer for the transthoracic approach and a 3.5 MHz transducer at the tip of a 9 mm gastroscope for examination from the esophagus. In 9 of 11 patients with atrial myxoma diagnosis was established by transthoracic echocardiography, whereas in 2 cases with reduced image quality at the conventional approach the tumor was identified by the transesophageal technique. In one of 5 patients with atrial thrombi acoustic properties and mobility could be better judged by transesophageal echocardiography. In 7 of 13 cases with pericardial tumors diagnosis was established by transthoracic echocardiography, whereas in 6 cases diagnosis was achieved by the transesophageal approach only. Thus, transesophageal echocardiography is suggested a decisive additional tool in diagnosis of heart tumors.  相似文献   

3.
We report a case of a 52-year-old patient with dilated cardiomyopathy who presented with worsening heart failure. Two-dimensional transthoracic echocardiography and real-time three dimensional transthoracic echocardiography showed severe dilated cardiac chambers, impaired ejection fraction and a mobile right atrial thrombus 2.6 × 1.0 cm in size, traversing the right atrial cavity during the whole cardiac cycle. After one week therapeutic anticoagulation, echocardiography confirmed no evidence of residual thrombus.  相似文献   

4.
Prosthetic heart valve (PHV) dysfunction remains difficult to recognise correctly by two-dimensional (2D) transthoracic and transoesophageal echocardiography (TTE/TEE). ECG-triggered multidetector-row computed tomography (MDCT), 18-fluorine-fluorodesoxyglucose positron emission tomography including low-dose CT (FDG-PET) and three-dimensional transoesophageal echocardiography (3D-TEE) may have additional value. This paper reviews the role of these novel imaging tools in the field of PHV obstruction and endocarditis.For acquired PHV obstruction, MDCT is of additional value in mechanical PHVs to differentiate pannus from thrombus as well as to dynamically study leaflet motion and opening/closing angles. For biological PHV obstruction, additional imaging is not beneficial as it does not change patient management. When performed on top of 2D-TTE/TEE, MDCT has additional value for the detection of both vegetations and pseudoaneurysms/abscesses in PHV endocarditis. FDG-PET has no complementary value for the detection of vegetations; however, it appears more sensitive in the early detection of pseudoaneurysms/abscesses. Furthermore, FDG-PET enables the detection of metastatic and primary extra-cardiac infections. Evidence for the additional value of 3D-TEE is scarce.As clinical implications are major, clinicians should have a low threshold to perform additional MDCT in acquired mechanical PHV obstruction. For suspected PHV endocarditis, both FDG-PET and MDCT have complementary value.  相似文献   

5.
Objective. To determine the influence of transoesophageal echocardiography (TEE) on therapy and prognosis in patients with cryptogenic transient ischaemic attack (TIA) or ischaemic stroke under the age of 50 years. Methods and results. We evaluated all patients aged 50 and under who were referred to our university hospital for cryptogenic TIA or ischaemic stroke during the period 1 January 1996 to 31 December 2004. All patients underwent both transthoracic echocardiography (TTE) and TEE. Patients with known pre-existent heart disease, such as atrial fibrillation, were excluded. Eighty-three patients with TIA (22) and ischaemic stroke (61) were enrolled. Mean age was 39±8 years (range 18 to 50). In 30% of the patients TEE detected one or more potential cardioembolic source, compared with 10% for TTE (p=0.003). Standard treatment (aspirin 38 mg daily) was changed in 7% of the patients due to the TEE findings. Complete followup was obtained in 93% with an average of 5±3 years. Twelve recurrences occurred; two out of six patients (33%) with therapy change and ten out of 71 (14%) of the patients without therapy change had a recurrent TIA or ischaemic Stroke. Conclusion. In patients with cryptogenic TIA or ischaemic stroke, TEE is superior to TTE in the detection of a potential cardiac source of embolism. However, findings obtained by TEE only influence the already initiated treatment in a small percentage of patients. The recurrence rate both in the group with and without therapy change is high. (Neth Heart J 2009;17:373–7.)  相似文献   

6.
An 81 year old woman, diagnosed with rheumatic mitral valve disease and atrial fibrillation ten years previous, was admitted due to a right carotid transient ischemic attack and a acute coronary syndrome. No ST elevation was noted in the region supplied by the anterior descending artery coronary (troponin T increased and anterolateral negative waves T). In recent years years, she had maintained with (anticoagulants) an INR of 2.5-3.5; however, in the previous month the INR had dropped to 1.8. The transthoracic echocardiography showed an anterolateral hypokinesis and a globular hyperechoic mass of 2 x 4 cm which appeared to be a free floating thrombus in the dilated left atrium. This occasionally caused occlusion of the mitral valve, which itself had a severe rheumatic stenosis of approximately 1 cm2. Due to the high risk of occlusion of the mitral valve and systemic embolisms, the mitral valve replacement and thrombectomy was recommend to the patient. The patient refused this treatment and subsequently died 5 days later. This case emphasizes the importance of a suitable level of anticoagulation (INR between 2,5 and 3,5) in patients with mitral stenosis and chronic atrial fibrillation. These cases have a the high risk of thromboembolism, and urgent surgery is mandatory when a free floating left atrial thrombus is observed.  相似文献   

7.

Objectives

Atrioventricular block (AVB) is a infrequent and serious complication after percutaneous ASD closure. In this study, we report on the incidence of AVB associated with intraoperative device closure of the ASD with transthoracic minimal invasion, and the outcomes of this complication in our center.

Methods

Between May 2006 and January 2011, a total of 213 secundum-type ASD patients were accepted in our hospital for intraoperative and transthoracic device closure with a domestic occluder. All patients were assessed by real-time transthoracic echocardiography (TTE) and electrocardiograph (ECG).

Results

All patients were occluded successfully under this approach. Immediate postprocedure third-degree AVB was observed in two patients. Since heart rates were in the range of about 50 to 55 beats per minute, no intervention was needed except for close observation for one patient. Another patient who recovered sinus rhythm intermittently during the operation was fitted with a temporary pacemaker. Approximately one week following glucocorticoid treatment, the AVB resolved spontaneously in these two patients. Mobitz type II AVB occurred in three patients during the procedure. Two patients developed post-operative cardiac arrest and were rescued successfully with cardiopulmonary resuscitation. One other patient changed to Mobitz type I AVB after three days. During the follow-up period, which ranged from six months to five years, no further occurrence of AVB was found.

Conclusions

Intraoperative and transthoracic device closure of secundum ASDs with domestic occluder resulted in excellent closure rate. AVB is an infrequent but serious complication during and after device closure of a secundum ASD. AVB is a complication that warrants greater attention and long-term follow-up.  相似文献   

8.
In vitro studies with the transprosthetic drainage system (TDS) have revealed a reduction in intrafemoral pressure in cemented total hip prosthesis. The aim of the present study was to establish whether the incidence of fat embolic syndrome (FES) is also reduced. Ten patients underwent standardized cemented total hip replacement using TDS under standardized general anaesthesia. The usual peri-operative monitoring measures were extended to include cardiopulmonary monitoring (pulmonary artery catheter, intra-arterial blood pressure) and two-dimensional transoesophageal echocardiography. Previous studies had reported an increased risk for fat embolic syndrome with conventional, and even with vacuum cementing techniques. Our recorded cardiopulmonary data and the data provided by two-dimensional transoesophageal echocardiography show a significant reduction in pulmonary embolism with TDS. This technique can be recommended in particular for high-risk patients (osteoporosis, elderly patients) and the implantation of long femoral stems. On the basis of the clinical data, a new femoral stem allowing the use of the TDS technique is being developed.  相似文献   

9.
Although aortography is well known as the “gold standard” for the diagnosis of coarctation of aorta (CoA), the method is invasive, expensive and not readily accepted by some patients. Ultrasound diagnosis for CoA is non-invasive, inexpensive, readily accepted by every patient, and can be repeated as frequently as necessary. The purpose of this presentation is to evaluate the applicability of transthoracic echocardiography for the diagnosis of CoA. The echocardiographic appearances of 53 patients with CoA who had undergone surgery during a 5-year period from January 2008 to October 2012 were analyzed retrospectively, and the results were compared with findings at surgery. Fifty-three patients with CoA include six with isolated CoA and 47 of CoA associated with other cardiac anomalies. Of the 53 operated patients, 48 were correctly diagnosed preoperatively by echocardiography, while two were misdiagnosed as interrupted aortic arch and the diagnosis were missed in three other patients. Thus the diagnostic accuracy rate was 90.6%, and the misdiagnosis rate was 9.4%. Preoperative echocardiographic evaluation offers very satisfactory anatomic assessment in most patients with CoA. It makes preoperative angiography unnecessary. Thus transthoracic echocardiography should be the first-line method for the diagnosis of coarctation of the aorta.  相似文献   

10.
目的:比较对比增强经颅多普勒超声与经胸壁超声心动图、经食管超声心动图对心房右→左分流患者的鉴别诊断价值。方法:回顾性分析2014年9月至2018年11月哈尔滨医科大学附属第一医院经手术证实的41例心房右→左分流患者对比增强经颅多普勒超声及经胸壁超声心动图的检查所见及诊断结果,并回顾性分析其中29例患者对比增强经颅多普勒超声、经胸壁超声心动图及经食管超声心动图的检查所见及诊断结果。结果:在经手术证实的41例心房右→左分流患者中,对比增强经颅多普勒超声检查阳性结果 41例,阴性结果 0例,诊断准确性为100%;经胸壁超声心动图检查阳性结果 20例,阴性结果 21例,诊断准确性为48.8%。其中,同时进行对比增强经颅多普勒超声、经胸壁超声心动图及经食管超声心动图检查的29例患者中,经胸壁超声心动图阳性结果 12例,阴性结果 17例,诊断准确性为41.4%;经食管超声心动图检查阳性结果 24例,阴性结果 5例,诊断准确性为82.8%。结论:对比增强经颅多普勒超声可提高心房右→左分流的诊断准确率,其与经胸壁超声心动图及经食管超声心动图结合应用可提高心房右→左分流的鉴别诊断能力。  相似文献   

11.
目的:探讨经胸超声心动图引导下行房间隔缺损封堵术治疗先天性房间隔缺损(Atrial septal defect,ASD)的临床疗效。方法:比较先天性ASD患者行超声心动图组(49例)或介入组(53例),患者的疗效及心脏功能的变化。结果:超声心动图组并发症发生率显著低于介入组(P0.05);术后4周,两组患者的心率、舒张期室间隔厚度(Interventricular septal thickness,IVST)、左室后壁厚度(Left ventricular posterior wall thickness,LVPWT)、左心室心肌重量(Left ventricular mass,LVM)和左心室心肌重量指数(Left ventricular mass index,LVMI)明显降低(P0.05),左心室射血分数(Left ventricular ejection fraction,LVEF)和左心室高峰充盈率(Left ventricular peak filling rate,LVPFR)均显著升高(P0.05),其余指标则无明显变化(P0.05);但术后1周超声心动图组的LVEF、IVST和LVMI即显著高于术前(P0.05)。结论:胸超声心动图引导下行ASD封堵术与X线介入封堵术疗效相当,但前者可能对ASD患者的心脏功能的改善更为显著。  相似文献   

12.
Valve replacement in patients with mitral valve regurgitation is indicated when symptoms occur or left ventricular function becomes impaired. Using different surgical techniques, mitral valve reconstruction has lead to earlier interventions with good clinical results. In order to determine the possibility of a mitral valve reconstruction, echocardiographic parameters are necessary. With transoesophageal echocardiography a segmental analysis of the entire mitral valve can be performed; mitral valve motion abnormalities and severity and direction of the regurgitation jet can be judged. From this analysis clues for underlying pathology can be derived as well as the eligibility of a successful mitral valve reconstruction. This article focuses on transoesophageal examination with segmental analysis in patients with mitral valve regurgitation.  相似文献   

13.
In a 62-year-old man with permanent atrial fibrillation and recurrent stroke, a large right atrial thrombus attached to a permanent pacemaker lead was incidentally identified by transesophageal echocardiography. Surgical treatment, recommended because of the large dimensions of the mass, was refused by the patient, and thrombus was successfully dissolved by anticoagulant treatment. Pathogenesis of pacemaker lead thrombosis, clinical implications, diagnostic and therapeutic options are discussed.  相似文献   

14.
殷闯  王英  兰春伟  尉娜  谭军 《蛇志》2017,(2):131-132
目的探讨心脏磁共振成像技术在不明原因缺血性脑卒中患者病因筛查中的应用价值。方法选取2014年9月~2015年2月在我院诊治的不明原因缺血性脑卒中患者53例为研究对象,均行心脏MRI和经胸超声心动图检查,并对检查出卵圆孔未闭(PFO)的患者进行分析。结果 53例不明原因缺血性脑卒中患者中,心脏MRI检查诊断合并PFO为27例(50.94%),经胸超声动图(TTE)检查诊断合并PFO为7例(13.21%),差异有统计学意义(P0.001)。结论心脏MRI对PFO的检出率较高,可作为不明原因缺血性脑卒中患者病因筛查的有效手段。  相似文献   

15.
The aim of the present study was to test the validity of the transthoracic electrical bioimpedance method PhysioFlow® to measure stroke volume in patients with chronic anemia. Stroke volume index (SVI), as well as cardiac index (CI) obtained by transthoracic electrical bioimpedance method and doppler echocardiography were compared in healthy subjects (n = 25) and patients with chronic anemia (i.e. mainly with sickle cell anemia; n = 32), at rest. While doppler echocardiography was able to detect difference in SVI between the two populations, the Physioflow® failed to detect any difference. Bland & Altman analyses have demonstrated no interchangeability between the two methods to assess CI and SVI in anemic patients and healthy subjects. While doppler echocardiography displayed a good concordance for SVI results with those obtained in the literature for anemic patients, the Physioflow® did not. Finally, in contrast to doppler echocardiography: 1) the CI obtained with the Physioflow® was not correlated with the hemoglobin level and 2) the stroke volume determined by the Physioflow® was highly influenced by body surface area. In conclusion, our findings indicate that the Physioflow® device is inaccurate for the measurement of SVI and CI in patients with chronic anemia and has a poor accuracy for the measurement of these parameters in African healthy subjects.  相似文献   

16.
Cardiac tumours may display diverse symptoms through potential involvement of any structure of the heart. We describe a case of a highly malignant thymoma with involvement of different cardiac structures with important haemodynamic compromise. With the high sensitivity of transthoracic echocardiography for detection of intracardiac masses, computed tomography and magnetic resonance add essential structural preoperative information on the tumour and surrounding tissue as vessels, pleura, lung and mediastinum.  相似文献   

17.
31 years lady with complete atrioventricular canal defect, large primum atrial septal defect (ASD), inlet ventricular septal defect (VSD) and Eisenmenger syndrome, presented with atrial flutter and complete heart block. She was not suitable for corrective cardiac surgery and not yet indicated for heart-lung transplantation. She was advised single chamber permanent pacemaker and eventually Micra VR transcatheter leadless pacemaker was finalised for her. Transcatheter leadless pacemaker was deployed in her RV septum despite some unforeseen technical problems. This patient had intrahepatic interruption of IVC with Azygous continuation draining into SVC but this altered venovascular course was detected only fluoroscopically midway during the pacemaker implantation procedure and this was not detected in the preprocedural transthoracic echocardiography. This abnormal venous course was clearly demonstrated in the cardiac CT which was performed only after completion of the pacemaker implantation procedure in this patient. The technical challenges encountered mainly were mostly during the manipulation of the 27F delivery catheter of Micra through this altered cardiovascular anatomy via transfemoral approach and also due to the presence of septal defects. Thus, transcatheter leadless permanent pacemaker was implanted successfully through transfemoral access in this complex congenital heart disease with interrupted IVC and azygous continuation. Besides transthoracic echocardiography, it may be better to perform transesophageal echocardiography or even preferably radiological imaging like cardiac CT or MRI prior to transcatheter leadless pacemaker implantation in patients with complex congenital heart disease to understand the cardiovascular anatomy and plan the procedure.  相似文献   

18.
A 28-year-old male presenting with atrial fibrillation (AF) underwent successful electrical cardioversion to restore sinus rhythm. He had no prior history of AF or other cardiac disease. However, transthoracic echocardiography (TTE), performed to exclude structural abnormalities as a cause of AF, demonstrated a large mass in the left atrium (LA). For further analysis the patient was referred to our centre, and echocardiography, multislice detector computed tomography (MDCT) and cardiovascular magnetic resonance imaging (CMR) were performed for further noninvasive diagnostic work-up.  相似文献   

19.
The survival of patients with a head-and-neck squamous cell carcinoma is determined by loco-regional recurrence and second primary carcinomas. As a complement to histopathology, molecular changes of tumour marginal and tumour distant tissue may confirm curative surgical tumour extirpation. We tested telomerase activity with PCR-ELISA kits.20 tumour margin biopsies were chosen by the surgeon from 20 patients. In addition, 3 tissue samples were taken from each of 20 additional patients, one from the carcinoma centre, the tumour margin and one distant from the tumour. 50% of the carcinoma centres were telomerase-positive. Thirteen of the 40 tumour margin samples showed increased telomerase levels, and in 3 of these residual carcinoma was histopathologically detected. Six of the 20 tumour distant tissues revealed increased telomerase levels. Telomerase positivity in carcinoma-free tumour margins correlated with a good prognosis. Confirmation of the results in a larger patient group is needed.  相似文献   

20.
M K Kapral  F L Silver 《CMAJ》1999,161(8):989-996
OBJECTIVE: To develop guidelines for the use of echocardiography in the investigation of patients with stroke. OPTIONS: (1) Routine transthoracic echocardiography (TTE); (2) routine transesophageal echocardiography (TEE); (3) routine TTE followed by TEE if the TTE findings are noncontributory; (4) selective TTE or TEE in patients with cardiac disease who would not otherwise receive anticoagulant therapy. OUTCOMES: This article reviews the available evidence on the yield of TTE and TEE in detecting cardiac sources of cerebral emboli in patients with stroke, the effectiveness of treatment for cardiac sources of emboli and the effectiveness of screening echocardiography for secondary stroke prevention. EVIDENCE: MEDLINE was searched for relevant articles published from January 1966 to April 1998; also reviewed were additional articles identified from the bibliographies and citations obtained from experts. BENEFITS, HARMS AND COSTS: Echocardiography can detect intracardiac masses (thrombus, vegetation or tumour) in about 4% (with TTE) to 11% (with TEE) of stroke patients. The yield is lower among patients without clinical evidence of cardiac disease by history, physical examination, electrocardiography or chest radiography (less than 2%) than among patients with clinical evidence of cardiac disease (less than 19%). The risks of echocardiography to patients are small. TTE has virtually no risks, and TEE is associated with cardiac, pulmonary and bleeding complications in 0.18%. Patients with an identified intracardiac thrombus are at increased risk for embolic events (absolute risk uncertain, range 0%-38%), and this appears to be reduced with anticoagulant therapy (absolute risk reduction uncertain). Anticoagulant therapy carries a risk of major hemorrhage of 1% to 3% per year. The overall effectiveness of echocardiography in the prevention of recurrent stroke is unknown. VALUES: The strength of evidence was evaluated using the methods of the Canadian Task Force on Preventive Health Care. RECOMMENDATIONS: There is fair evidence to recommend echocardiography in patients with stroke and clinical evidence of cardiac disease by history, physical examination, electrocardiography or chest radiography (grade B recommendation). There is insufficient evidence to recommend for or against TEE in patients with normal results of TTE (grade C recommendation). There is insufficient evidence to recommend for or against routine echocardiography in patients (including young patients) without clinical cardiac disease (grade C recommendation). Routine echocardiography is not recommended for patients with clinical cardiac disease who have independent indications for or contraindications to anticoagulant therapy (grade D recommendation). There is fair evidence to recommend anticoagulant therapy in patients with stroke and intracardiac thrombus (grade B recommendation). There is insufficient (no) evidence to recommend for or against any specific therapy for patent foramen ovale (grade C recommendation). VALIDATION: The findings of this analysis were reviewed through an iterative process by the members of the Canadian Task Force on Preventive Health Care.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏