首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Methods for the measurement of gentamicin concentration in several bovine tissues were developed and validated. A novel liquid chromatographic (LC) technique employed trifluoroacetic acid in the mobile phase so that all gentamicin components co-eluted. Analytes were ionized by positive-ion pneumatically assisted electrospray and detected by selected reaction monitoring (SRM) with an LC-tandem mass spectrometer (LC/MS/MS). Calibration of plasma and urine samples was based on tobramycin internal standard. Calibration of milk and kidney samples was based on external standard, due to variability of tobramycin response in these matrices. The extraction technique employed treatment with aqueous trichloroacetic acid to both precipitate protein and liberate gentamicin from the matrix. Milk samples had to be defatted by centrifugation prior to extraction. Urine samples were further cleaned up with C-18 solid phase extraction (SPE). These methods were validated for use in several residue depletion studies (reported elsewhere) to monitor the depletion of gentamicin in tissues under various dosing conditions. The plasma method was calibrated from 1 to 5000 ng/mL in two ranges, with a limit of quantitation (LOQ) in the low range calculated at 3.3 ng/mL. The milk method was calibrated from 2.5 to 2500 ng/mL with an LOQ calculated at 4.5 ng/mL. The urine method was designed for use at low levels, and was calibrated from 1 to 100 ng/mL with an LOQ of 3.8 ng/mL. The kidney method was primarily designed for analysis of small samples (approximately 100mg). This method was calibrated from 10 to 50,000 ng/g with an LOQ of 26 ng/g.  相似文献   

2.
Valproyl taurinamides are a novel group of compounds that possess anticonvulsant activity. In this study a gas chromatographic micromethod was developed for the quantification of selected valproyl taurinamides and some of their metabolites in biological samples. Valproyl taurinamide (VTD), N-methyl valproyl taurinamide (M-VTD), N,N-dimethyl valproyl taurinamide (DM-VTD) and N-isopropyl valproyl taurinamide (I-VTD) were analyzed in mouse and dog plasma and in dog urine using gas chromatography. Flame ionization detection and mass spectrometric detection were compared. The plasma samples were prepared by solid-phase extraction using C(18) cartridges. The urine samples were prepared by liquid-liquid extraction. The sample volume used was 100 microl of dog plasma, 50 microl of mouse plasma and 20 microl of dog or mouse urine. The quantification range of the method was 1.5-50 mg/l in dog plasma (VTD only), 2.5-250 mg/l in mouse plasma (0.7-90 pmol injected) and 0.04-2 mg/ml in dog urine (VTD only). The inter-day precision in plasma and urine samples was around 10% for all quantified concentrations except LOQ (15-20%). The accuracy for all four compounds was between 90 and 110% within the entire concentration range. The developed method was suitable for quantification of a series of CNS-active valproyl taurineamide derivatives in biological samples at relevant in vivo concentrations.  相似文献   

3.
A method is described for the determination of the antiarrhythmic drug lorcainide hydrochloride and its three main metabolites in plasma, urine, faeces and tissues from man and animals. The procedure involves the extraction of the parent drug, its metabolites and the internal standard from the biological materials at different alkaline pH values, back-extraction into sulphuric acid and re-extraction into the organic phase (heptane—isoamyl alcohol). After silylation of the different phenolic and the N-dealkylated metabolites, analyses were carried out by automated gas—liquid chromatography with electron-capture detection. The method has a sensitivity limit of 5 ng for lorcainide, and 10–20 ng for the various metabolites, per millilitre of plasma.The method was applied to urine, faeces, plasma and tissue samples from man and animals. It was also suitable for automatic sample analysis.  相似文献   

4.
A method based on liquid-liquid-liquid microextraction combined with corona discharge ion mobility spectrometry was developed for the analysis of amantadine in human urine and plasma samples. Amantadine was extracted from alkaline aqueous sample as donor phase through a thin phase of organic solvent (n-dodecane) filling the pores of the hollow fiber wall and then back extracted into the organic acceptor phase (methanol) located in the lumen of the hollow fiber. All variables affecting the extraction of analyte including acceptor organic solvent type, concentration of NaOH in donor phase, ionic strength of the sample and extraction time were studied. The linear range was 20-1000 and 5-250 ng/mL for plasma and urine, respectively (r(2)≥0.990). The limits of detection were calculated to be 7.2 and 1.6 ng/mL for plasma and urine, respectively. The relative standard deviation was lower than 8.2% for both urine and plasma samples. The enrichment factors were between 45 and 54. The method was successfully applied for the analysis of amantadine in urine and plasma samples.  相似文献   

5.
Astragaloside IV is a novel cardioprotective agent extracted from the Chinese medical herb Astragalus membranaceus (Fisch) Bge. This agent is being developed for treatment for cardiovascular disease. Further development of Astragaloside IV will require detailed pharmacokinetic studies in preclinical animal models. Therefore, we established a sensitive and accurate high performance liquid chromatography (HPLC) coupled with tandem mass spectrometry (LC/MS/MS) quantitative detection method for measurement of Astragaloside IV levels in plasma, urine as well as other biological samples including bile fluid, feces and various tissues. Extraction of Astragaloside IV from plasma and other biological samples was performed by Waters OASIS(trade mark) solid phase extraction column by washing with water and eluting with methanol, respectively. An aliquot of extracted residues was injected into LC/MS/MS system with separation by a Cosmosil C18 5 microm, 150 mm x 2.0 mm) column. Acetonitrile:water containing 5 microM NaAc (40:60, v/v) was used as a mobile phase. The eluted compounds were detected by tandem mass spectrometry. The average extraction recoveries were greater than 89% for Astragaloside IV and digoxin from plasma, while extraction recovery of Astragaloside IV and digoxin from tissues, bile fluid, urine and fece ranged from 61 to 85%, respectively. Good linearity (R2>0.9999) was observed throughout the range of 10-5000 ng/ml in 0.5 ml rat plasma and 5-5000 ng/ml in 0.5 ml dog plasma. In addition, good linearity (R2>0.9999) was also observed in urine, bile fluid, feces samples and various tissue samples. The overall accuracy of this method was 93-110% for both rat plasma and dog plasma. Intra-assay and inter-assay variabilities were less than 15.03% in plasma. The lowest quantitation limit of Astragaloside IV was 10 ng/ml in 0.5 ml rat plasma and 5 ng/ml in 0.5 ml dog plasma, respectively. Practical utility of this new LC/MS/MS method was confirmed in pilot pharmacokinetic studies in both rats and dogs following intravenous administration.  相似文献   

6.
F J Ehlert  H I Yamamura 《Life sciences》1984,34(24):2347-2355
The influence of cinnarizine, flunarizine and lidoflazine on [3H]nitrendipine binding in the cerebral cortex, heart and longitudinal muscle of the ileum was investigated. When assays were run in Ca++ free Tris/HCl buffer on extensively washed tissue homogenates, cinnarizine, flunarizine and lidoflazine were approximately equipotent inhibitors of [3H] nitrendipine binding in the heart and cerebral cortex, with Ki values of approximately 10(-6) M. In contrast, the compounds were 4 to 100 times more potent in the ileum with the rank order of potency being: lidoflazine greater than flunarizine greater than cinnarizine. The same rank order of potency was observed in the ileum when assays were run in the presence of 1 mM Ca++, although all three drugs were somewhat less potent. Similarly, Ca++ inhibited the binding of the cinnarizine-like drugs in the cerebral cortex and heart as well, with all drugs being less potent than that observed in the ileum under similar assay conditions.  相似文献   

7.
A sensitive and specific analytical method was developed for determination of Ro 19–6327 (Lazabemide) in human plasma and urine samples to provide pharmacokinetic data from clinical trials. The new method employs a simple liquid-liquid extraction to isolate the drug from biological samples. The extract is reacted to form the trifluoroacetyl derivative of Ro 19–6327 and then analyzed by gas chromatography-negative chemical ionization mass spectrometry (GC-NCIMS). The lower limit of quantitation of the assay is 0.05 ng/ml for plasma and 5.0 ng/ml for urine, based on 1-ml aliquots. No interferences from anticoagulants, collection devices, or endogenous constituents of plasma and urine were observed. Recovery (64.3%), inter-assay precision (<8% R.S.D.), and accuracy (>85%) of the method were considered acceptable. The assay proved reliable enough to be automated for unattended sample analysis of approximately 50 samples daily. In an additional series of tests, Ro 19–6327 was shown to be stable under conditions that might be encountered during the analysis of samples from clinical trials.  相似文献   

8.
In this study, a novel method is described for the determination of tramadol in biological fluids using molecularly imprinted solid-phase extraction (MISPE) as the sample clean-up technique combined with high-performance liquid chromatography (HPLC). The water-compatible molecularly imprinted polymers (MIPs) were prepared using methacrylic acid as functional monomer, ethylene glycol dimethacrylate as cross-linker, chloroform as porogen and tramadol as template molecule. The novel imprinted polymer was used as a solid-phase extraction (SPE) sorbent for the extraction of tramadol from human plasma and urine. Various parameters affecting the extraction efficiency of the polymer have been evaluated. The optimal conditions for the MIP cartridges were studied. The MIP selectivity was evaluated by checking several substances with similar molecular structures to that of tramadol. The limit of detection (LOD) and limit of quantification (LOQ) for tramadol in urine samples were 1.2 and 3.5 μg L−1, respectively. These limits for tramadol in plasma samples were 3.0 and 8.5 μg L−1, respectively. The recoveries for plasma and urine samples were higher than 91%.  相似文献   

9.
A simple and sensitive high-performance liquid chromatograhic (HPLC) method for the determination of (+)-(S)-sotalol and (−)-(R)-sotalol in biological fluids was established. Following extraction with isopropyl alcohol from biological samples on a Sep-Pak C18 cartridge, the eluent was derivatized with 2,3,4,6-tetra-O-acetyl-β-d-glucopyranosol isothiocyanate (GITC). The diastereoisomeric derivatives are resolved by HPLC with UV detection at 225 nm. Calibration was linear from 0.022 to 4.41 μg/ml in human plasma and from 0.22 to 88.2 μg/ml in human urine for both (+)-(S)- and (−)-(R)-sotalol. The lower limit of determination was 0.022 μg/ml for plasma and 0.22 μg/ml for urine. The within-day and day-to-day coefficients of variation were less than 7.5% for each enantiomer at 0.09 and 1.8 μg/ml in plasma and at 0.44 and 4.4 μg/ml in urine. The method is also applicable to other biological specimens such as rat, mouse and rabbit plasma.  相似文献   

10.
Alkylphenols, 4-nonylphenol (NP) and 4-tert-octylphenol (OP), in human urine and plasma samples were analyzed using stir bar sorptive extraction (SBSE) in combination with thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS). The method involved correction by stable isotopically labeled surrogate standards, 4-(1-methyl)octylphenol-d5 (m-OP-d5) and deuterium 4-tert-octylphenol (OP-d). A biological sample was extracted for 60 min at room temperature (25 degrees C) using a stir bar coated with a 500 microm thick polydimethylsiloxane (PDMS) layer. Then, the stir bar was analyzed by TD-GC-MS in the selected ion monitoring (SIM) mode without any derivatization step. The average recoveries in human urine and plasma samples spiked with NP and OP at levels of 0.5 and 10 ng ml-1 were between 95.8 and 99.8% with correction using the added surrogate standards. The limits of quantitation were 0.2 ng ml-1 for NP and 0.02 ng ml-1 for OP. We measured the background levels of NP and OP in five human urine and three human plasma samples from healthy volunteers. NP and OP were not detected in all human urine samples (N.D. < 0.2 ng ml-1 for NP, and N.D. < 0.02 ng ml-1 for OP). However, 0.2-0.3 ng ml-1 for NP and 0.1-0.2 ng ml-1 for OP in human plasma samples were observed by this method.  相似文献   

11.
A solid-phase extraction (SPE) method for sample clean-up followed by a reversed-phase HPLC procedure for the assay of alinastina (pINN) in biological fluids is reported. The effects of the sample pH, composition of the washing and elution solvents and the nature of the SPE cartridge on recovery were evaluated. The selectivity of SPE was examined using spiked rat urine and plasma samples and the CH and PH cartridges gave rise to the cleanest extracts. The recoveries obtained in spiked rat urine and plasma samples were 91.2±2.7 and 99.9±2.8%, respectively. The proposed SPE method coupled off-line with a reserved-phase HPLC system with fluorimetric detection was applied to the quantitation of alinastine in real rat urine samples. The analytical method was also applied and validated for the determination of alinastine in dog plasma. The recovery from spiked dog plasma samples using the PH cartridge was around 65%. The within-day and between-day precisions were 7 and 12%, respectively. The detection and quantitation limits in dog plasma were 0.024 and 0.078 μg/ml, respectively.  相似文献   

12.
A sensitive and specific method using reversed-phase liquid chromatography coupled with electrospray ionization-mass spectrometry (LC-ESI-MS) has been developed for the quantitative determination of flunitrazepam (F) and its metabolites 7-aminoflunitrazepam (7-AF), N-desmethylflunitrazepam (N-DMF) and 3-hydroxyflunitrazepam (3-OHF) in biological fluids. After the addition of deuterium labelled standards of F,7-AF and N-DMF, the drugs were isolated from urine or plasma by automated solid-phase extraction, then chromatographed in an isocratic elution mode with a salt-free eluent. The quantification was performed using selected ion monitoring of protonated molecular ions (M+H(+)). Experiments were carried out to improve the extraction recovery (81-100%) and the sensitivity (limit of detection 0.025 ng/ml for F and 7-AF, 0.040 ng/ml for N-DMF and 0.200 ng/ml for 3-OHF). The method was applied to the determination of F and metabolites in drug addicts including withdrawal urine samples and in one date-rape plasma and urine sample.  相似文献   

13.
A specific assay method for radiolabelled digoxin and its known apolar metabolites in plasma, urine and saliva was developed. The assay permits the delineation of the pharmacokinetics of digoxin and its metabolites after single-dose administration of the drug to humans. Column chromatographic and solvent extraction procedures were used for the separation of apolar and polar compounds. Thin-layer chromatography was applied for the individual and specific assessment of digoxin and its apolar metabolites. Apolar and polar standards were used for quantitative assessments of all the procedures used. Accuracy and precision of the assay developed were evaluated in plasma, urine and saliva using biological samples spiked with known amounts of standards and by measuring replicates of biological samples obtained from pharmacokinetic studies with digoxin administration to humans.  相似文献   

14.
A gas chromatography-mass spectrometry (GC-MS) method was developed for the quantitative analysis of free amino acids as their propyl chloroformate derivatives in biological fluids. Derivatization with propyl chloroformate is carried out directly in the biological samples without prior protein precipitation or solid-phase extraction of the amino acids, thereby allowing automation of the entire procedure, including addition of reagents, extraction and injection into the GC-MS. The total analysis time was 30 min and 30 amino acids could be reliably quantified using 19 stable isotope-labeled amino acids as internal standards. Limits of detection (LOD) and lower limits of quantification (LLOQ) were in the range of 0.03-12 microM and 0.3-30 microM, respectively. The method was validated using a certified amino acid standard and reference plasma, and its applicability to different biological fluids was shown. Intra-day precision for the analysis of human urine, blood plasma, and cell culture medium was 2.0-8.8%, 0.9-8.3%, and 2.0-14.3%, respectively, while the inter-day precision for human urine was 1.5-14.1%.  相似文献   

15.
A HPLC method with improved sensitivity for the determination of ochratoxins (OT) A, B and alpha in plasma and milk was developed. Plasma analysis involved a simple liquid-liquid extraction with chloroform; while for milk, an additional immunoaffinity clean-up step was necessary. The method showed a good linearity (r(2)>0.999). The limit of quantification (LOQ) of OTA was 5 and 200 ng/l for milk and plasma, respectively. Average recovery was 89% in both matrices, except for OTalpha in milk that was only 18% due to poor immunoaffinity binding. OT remained stable in -20 degrees C stored samples; OTA concentration in plasma and milk did not change after 8 and 18 months of storage, respectively. The developed method has been applied to contaminated plasma and milk samples obtained from dairy ewes fed with ochratoxin-contaminated feed.  相似文献   

16.
Nalmefene and naltrexone are used to block the effects of narcotics and alcohol. In the present work, for the first time a microextraction technique was presented to reduce matrix interferences and improve detection limits of the drugs in urine and plasma samples. Electromembrane extraction (EME) followed by high performance liquid chromatography (HPLC) coupled with ultraviolet (UV) detection was optimized and validated for quantification of nalmefene and naltrexone from biological fluids. The membrane consists 85% of 2-nitrophenyl octyl ether (NPOE) and 15% di-(2-ethylhexyl) phosphate (DEHP) immobilized in the pores of a hollow fiber. A 100 V electrical field was applied to make the analytes migrate from sample solution with pH 2.0, through the supported liquid membrane (SLM) into an acidic acceptor solution with pH 1.0 which was located inside the lumen of hollow fiber. Extraction recoveries in the range of 54% and 75% were obtained in different biological matrices which resulted in preconcentration factors in the range of 109-149 and satisfactory repeatability (2.0相似文献   

17.
A column-switching HPLC method using an internal-surface phenylboronic acid precolumn for the selective extraction of β-blockers from biological fluids has been developed. Filtered urine and plasma samples (50 μl) were injected onto the precolumn equilibrated with methanol-0.05 M disodium hydrogenphosphate (5:95, v/v). After the precolumn had been washed breifly, the selectively retained β-blockers were eluted with methol-0.05 M phosphate buffer (pH 2.0) and transferred to a reversed-phase analytical column, on which they were then separated. Even after exposure to at least 160 injections of non-treated urine and plasma samples, the retention efficiency of the precolumn was maintained with no increase in back pressure. Quantitative recoveries and good reproducibility were demonstrated with pindolol.  相似文献   

18.
A new molecularly imprinted polymer (MIP) material was synthesized selective for verapamil and utilized for on-line metabolic screening of this common calcium antagonist in biological samples. Since some metabolites of verapamil have also shown pharmacological properties, a selective and sensitive sample preparation approach that provides a metabolic profile in biologically relevant samples is important. The MIP material was coupled on-line to a restricted access material (RAM) precolumn. The multidimensional nature of this set-up removed large matrix interferents such as proteins from the sample, while the selectivity of the MIP enabled further cleanup of the smaller analytes. The selectivity and extraction efficiency of the MIP for verapamil and its metabolites was evaluated in various biological matrices, such as cell cultures and urine. The experimental set-up with the developed method enabled the direct injection of biological samples for the selective isolation, preconcentration, identification and analysis of verapamil and its phase I metabolites by LC-MS(n). This multidimensional approach provided much qualitative information about the metabolic profile of verapamil in various biological matrices. An analytical method was developed for the quantification of verapamil and gallopamil in urine, plasma and cell culture. Acceptable linearity (R(2)=0.9996, 0.9982 and 0.9762) with an average injection repeatability (n=3) of 10, 25 and 15% R.S.D. was determined for urine, plasma and cell culture, respectively. This is the first application of the procedure for the selective metabolic screening of verapamil in biological samples.  相似文献   

19.
A method was developed for screening human biological samples for poisonous anions using capillary electrophoresis (CE) employing indirect UV detection. The run buffer consisted of 2.25 mM pyromellitic acid, 1.6 mM triethanolamine, 0.75 mM hexamethonium hydroxide and 6.5mM NaOH at pH 7.7. Biological samples were pretreated using solid phase extraction. The method was applied to the analysis of human blood, plasma, urine, and intestinal contents. Twenty-nine different anions were detectable at aqueous concentrations of 1 part per million (ppm) with a typical analysis time less than 20 min. Intraday migration time R.S.D. and peak area R.S.D. for blood samples were less than 1.1% and 6.3%, respectively. Interday migration time R.S.D. for plasma samples ranged from 7.5% to 10.4%. The new method produced efficient separations of various target anions extracted from complex biological matrices.  相似文献   

20.
Aplidine (dehydrodidemnin B) is a new marine-derived depsipeptide with a powerful cytotoxic activity, which is under early clinical investigation in Europe and in the US. In order to investigate the pharmacokinetic properties of this novel drug, an HPLC–tandem mass spectrometry method was developed for the determination of aplidine in biological samples. Didemnin B, a hydroxy analogue, was used as internal standard. After protein precipitation with acetonitrile and extraction with chloroform, aplidine was chromatographed with a RP octadecylsilica column using a water–acetonitrile linear gradient in the presence of formic acid at the flow-rate of 500 μl/min. The method was linear over a 5–100 ng/ml range (LOD=0.5 ng/ml) in plasma and over a 1.25–125 ng/ml range (LOD=0.2 ng/ml) in urine with precision and accuracy below 14.0%. The intra- and inter-day precision and accuracy were below 12.5%. The extraction procedure recoveries for aplidine and didemnin B were 69% and 68%, respectively in plasma and 91% and 87%, respectively in urine. Differences in linearity, LOQ, LOD and recoveries between plasma and urine samples seem to be matrix-dependent. The applicability of the method was tested by measuring aplidine in rat plasma and urine after intravenous treatment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号