共查询到20条相似文献,搜索用时 15 毫秒
1.
Sphingomyelin (SM) and phosphatidylcholine (PC) are two major phospholipids on plasma lipoproteins. Their concentration is classically measured by lipid extraction, thin-layer chromatography, and phosphate determination on separated SM or PC spots. Here, we describe two rapid, specific, and sensitive enzymatic measurements for both phospholipids. Plasma was incubated with bacterial sphingomyelinase (for SM measurement) or bacterial PC-specific phospholipase D (for PC measurement), alkaline phosphatase, choline oxidase, peroxidase, N-ethyl-N-(2-hydroxy-3-sulfopropyl)-3,5-dimethoxyaniline, and 4-aminoantipyrine for 45 min. A blue dye, with an optimal absorption at 595 nm, was generated. PC levels did not influence SM measurement and vice versa. The linear range for the SM measurement was 0.5-5 microg, and that for PC was 2.5-20 microg. The mean percentage recovery was 98.0 +/- 5.2% for SM and 96.6 +/- 3.8% for PC. The interassay coefficient of variation of the assay was 1.7 +/- 0.05% for SM and 3.1 +/- 0.13% for PC. These two new methods are amenable to automation and can be adapted for large-scale, high-throughput assays. 相似文献
2.
Zhou Y Zhang J Guo B Yu J Shi Y Wang M Zhang Y 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(30):3119-3124
A rapid and highly sensitive liquid chromatography-tandem mass spectrometric (LC-MS/MS) method for simultaneous determination of cefoperazone sodium and sulbactam sodium in human plasma was developed. The analytes and internal standard (IS), cefuroxime sodium, were extracted from human plasma via liquid-liquid extraction with ethyl acetate and separated on a Waters Xterra C18 column within 3.5 min. Quantitation was performed on a triple quadrupole mass spectrometer employing electrospray ionization technique, operating in selected reaction monitoring (SRM) and negative ion mode. The precursor to product ion transitions monitored for cefoperazone, sulbactam and IS were m/z 644.1→528.0, 232.1→140.0, and 423.0→362.0, respectively. The assay was validated in the linear range of 0.1-20 μg/mL for cefoperazone and 0.02-4 μg/mL for sulbactam. The intra- and inter-day precisions (CV%) were within 8.39% for each analyte. The recoveries were greater than 87.3% for cefoperazone and 87.2% for sulbactam. Each analyte was found to be stable during all sample storage, preparation and analytical procedures. The method was successfully applied in a pharmacokinetic study of Sulperazon injection in six hospital-acquired pneumonia (HAP) patients. 相似文献
3.
为了使膨囊嵩草(Kobresia inflata P. C. Li)这一名称成为合格发表,指定了保存其主模式的标本馆.尽管该种常常具有穗状花序和单性小穗,被归属于异穗嵩草组(Sect. Hemicarex),但与该组植物并没有密切的亲缘关系,却与黑麦嵩草(K. loliacea Wang et Tang ex P. C. Li)和根茎嵩草(K. gammiei C. B. Clarke)等更近缘,因此应该归属于疏穗嵩草亚属(Subgen. Compositae). 相似文献
4.
A decoction of the leaves and stems of Desmodium adscendens (Fabaceae), a herb occurring in Africa and South America, is used in traditional medicine. Previous phytochemical research revealed that flavonoids, soyasaponins, β-phenylethylamines, and an indol-3-alkylamine were present. Our investigations have led to the identification of D-pinitol, a carbohydrate with antihyperglycemic, hepatoprotective and anti-inflammatory effects, as a potentially active compound. In order to prepare a quantified extract to be used in in vivo experiments, an analytical method was developed and validated.A gas chromatographic method was developed. Two different derivatization methods, i.e. acetylation and trimethylsilylation, were evaluated. Trimethylsilylation yielded repeatable results and was selected. Five different sugar alcohols were evaluated in order to find a suitable internal standard. Xylitol was chosen since it did not co-elute and its structure closely resembled D-pinitol. Sonication and reflux extraction were investigated in order to obtain a quantitative extraction. This was achieved through reflux extraction during 0.5 h.The method was validated according to the ICH guidelines. The calibration model appeared to be linear, ranging from 5.13 μL/mL to 25.65 μL/mL. The method was precise with an inter-day precision lower than 1.3%. The accuracy ranged from 103.38% to 105.84%. The validated method was used for quantification of D-pinitol in lyophilized decoctions from D. adscendens administered in in vivo experiments. Typically, a D-pinitol level about 5% was measured. Additionally, different food supplements available on the market were screened. The amount D-pinitol found in these supplements ranged from 1.8 mg/capsule to 30 mg/capsule and was 2.0 mg/mL solution. 相似文献
5.
Curticapean A Muntean D Curticapean M Dogaru M Vari C 《Journal of biochemical and biophysical methods》2008,70(6):1304-1312
The optimized method for HPLC determination of tramadol and its metabolite O-desmethyl tramadol in human plasma using sotalol as internal standard has been developed and validated by a new approach. The determination by fluorescence detection was performed on re-eluted solution, obtained after liquid–liquid extraction with ethyl acetate of the three analytes from plasma. The chromatographic separation of tramadol under a gradient elution was achieved at a temperature of 15 °C with a RP-18 column, guarded by a C18 precolumn. The mobile phase was a mixed aqueous solution containing ortho-phosphoric acid, triethylamine, acetonitrile and methanol in a complex gradient mode. The quantitative determination of tramadol was performed at different successive pairs of excitation/emission wavelengths (200/300 nm, 200/295 nm, 212/305 nm) with lower limits of quantification: LLOQ = 4.078 ng/ml for tramadol, respectively LLOQ = 3.271 ng/ml for O-desmethyl tramadol. For the LLOQ limits, were calculated the values of the coefficient of variation and difference between mean and the nominal concentration. For tramadol analyte they were CV% = 5.147% and bias% = − 7.273% in the intra-days and CV% = 4.894% and bias% = 0.836% in the between-days assay, respectively for the metabolite O-desmethyl tramadol they were CV% = 11.517% and bias% = 0.337% in the intra-days and CV% = 6.41% and bias% = 3.259% in the between-days assay.
In addition, the stabilities of the analytes were verified in different conditions. Both, tramadol and its metabolite proved to be stable in plasma for four weeks, frozen at − 20 °C, but also for 48 h at 15 °C in the re-eluted solution after liquid–liquid extraction. 相似文献
6.
Jimenez M Spaliviero JA Grootenhuis AJ Verhagen J Allan CM Handelsman DJ 《Biology of reproduction》2005,72(1):78-85
Sensitive and specific measurement of FSH is critical to research in reproductive biology, and the increasing availability of transgenic mouse models has created a need for a robust, sensitive, and specific mouse (m) FSH assay. The present study evaluated a time-resolved immunofluorometric assay (IFMA) for mFSH using monoclonal antibody to human (h) FSHbeta as a capture antibody and a biotinylated polyclonal antibody to rat alpha subunit as a detection probe, with signaling amplified by europium-labeled streptavidin. The mFSH IFMA lowered the detection limit 34-fold (5 vs. 170 pg/sample) compared with standard mFSH RIA. The mFSH IFMA demonstrated parallelism of response to dilutions of castrated mouse serum and rat FSH but no cross-reactivity with hFSH and mLH or hLH, whereas the RIA demonstrated nonparallel cross-reactivity with hFSH. The IFMA has a wide analytical range, with a good precision profile for within- and between-assay reproducibility. Because the IFMA is a sandwich-type assay with strict dimer-specificity by design, the lower readings and recovery obtained were compared with the RIA when both assays used a pituitary-purified mFSH assay standard that contained isolated or fragmented subunits as well as intact dimeric FSH. When used with mouse serum sample, the mFSH IFMA demonstrated the expected increases following orchidectomy as well as markedly enhanced sensitivity to very low levels of endogenous mFSH in gonadotropin-deficient mice. Furthermore, the IFMA measured mFSH with fidelity in both intact and orchidectomized male mice without any interference from transgenic hFSH. The greatly enhanced sensitivity, specificity, and technical convenience of this mFSH IFMA will allow wider application of FSH measurements to very small blood samples in immature and mature mice as well as transgenic models. 相似文献
7.
The aim of this study was to combine matrix metalloproteinase-9 (MMP-9) protein (enzyme-linked immunosorbent assay [ELISA]) and MMP-9 activity (fluorescence resonance energy transfer [FRET] assay) data to generate units of specific activity in endogenous and p-aminophenylmercuric acetate (APMA)-activated lithium heparin plasma. The results indicate that specific activity is constant in APMA-activated plasma (mean value = 1359.4 pmol/min/μg) and approximately 12% plasma MMP-9 is endogenously active. Exogenous tissue inhibitor of metalloproteinase-1 (TIMP-1) has a greater inhibitory effect on endogenously active MMP-9 than on APMA-activated MMP-9. In conclusion, specific activity can be used as a tool to monitor MMP-9 inhibition. APMA activation affects natural enzyme inhibition, possibly by chemical modification of the C-terminal portion of the enzyme containing the TIMP-1 binding site. 相似文献
8.
Vandooren J Geurts N Martens E Van den Steen PE Jonghe SD Herdewijn P Opdenakker G 《World journal of biological chemistry》2011,2(1):14-24
AIM: To establish a novel, sensitive and high-throughput gelatinolytic assay to define new inhibitors and compare domain deletion mutants of gelatinase B/matrix metalloproteinase (MMP)-9. METHODS: Fluorogenic Dye-quenched (DQ)TM-gelatin was used as a substrate and biochemical parameters (substrate and enzyme concentrations, DMSO solvent concentrations) were optimized to establish a highthroughput assay system. Various small-sized libraries (ChemDiv, InterBioScreen and ChemBridge) of hetero-cyclic, drug-like substances were tested and compared with prototypic inhibitors. RESULTS: First, we designed a test system with gelatin as a natural substrate. Second, the assay was validated by selecting a novel pyrimidine-2,4,6-trione (barbitu- rate) inhibitor. Third, and in line with present structural data on collagenolysis, it was found that deletion of the O-glycosylated region significantly decreased gelatinolytic activity (kcat/kM ± 40% less than full-length MMP-9). CONCLUSION: The DQTM-gelatin assay is useful in high-throughput drug screening and exosite targeting. We demonstrate that flexibility between the catalytic and hemopexin domain is functionally critical for gelatinolysis. 相似文献
9.
Stephen C. Kasper Peter L. Bonate Allyn F. DeLong 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1995,669(2)
A reversed-phase high-performance liquid chromatographic assay (HPLC) was utilized for monitoring xanomeline (LY246708/NNC 11–0232) and a metabolite, desmethylxanomeline, in human plasma. Xanomeline, desmethylxanomeline and internal standard were extracted from plasma with hexane at basic pH. The organic solvent extract was evaporated to dryness with nitrogen and the dried residue was reconstituted with 0.2 M HCl-methanol (50:50, v/v). A Zorbax CN 150 × 4.6 mm I.D., 5-μm column and mobile phase consisting of 0.5% (5 ml/l) triethylamine (TEA) adjusted to pH 3.0 with concentrated orthophosphoric acid-tetrahydrofuran (THF) (70:30, v/v) produced consistent resolution of analytes from endogenous co-extracted plasma components. Column effluent was monitored at 296 nm/0.008 a.u.f.s. and the assay limit of quantification was 1.5 ng/ml. A linear response of 1.5 to 20 ng/ml was sufficient to monitor plasma drug/metabolite concentrations during clinical trials. HPLC assay validation as well as routine assay quality control (QC) samples indicated assay precision/accuracy was better than ±15%. 相似文献
10.
RD-114 virus infectivity assay by measurements of DNA polymerase activity and virus group specific antigen 总被引:4,自引:0,他引:4
J E Filbert R M McAllister M O Nicolson R V Gilden E H Lennette 《Proceedings of the Society for Experimental Biology and Medicine. Society for Experimental Biology and Medicine (New York, N.Y.)》1974,145(2):366-370
11.
Chen X Zhong D Xu H Schug B Blume H 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2002,768(2):267-275
A sensitive and specific procedure for the simultaneous determination of dihydroergotamine (DHE) and its 8'-hydroxylated metabolite (8'-OH-DHE) in human plasma was developed and validated. The analytes were extracted from plasma samples by liquid-liquid extraction, separated through a Zorbax C18 column (50x2.1 mm I.D.) and detected by tandem mass spectrometry with an electrospray ionization interface. Caroverine was used as the internal standard. The method has a lower limit of quantitation (LOQ) of 10.0 and 11.0 pg/ml for DHE and 8'-OH-DHE, respectively. The intra- and inter-run precision was measured to be below 9.1% for both DHE and 8'-OH-DHE. The inter-run accuracy was within 4% for the analytes. The overall extraction recoveries of DHE and 8'-OH-DHE were determined to be about 58 and 52% on average, respectively. The chromatographic run time was approximately 2.5 min. More than 120 samples could be assayed daily with this method, including sample preparation, data acquisition and processing. The method developed was successfully used to investigate plasma concentrations of DHE and 8'-OH-DHE in a pharmacokinetic study of volunteers who received DHE orally. 相似文献
12.
Ghosh R 《Biotechnology and bioengineering》2006,93(2):280-285
This paper discusses a membrane chromatographic immunoassay method for rapid detection and quantitative analysis of specific serum antibodies. A type of polyvinylidine fluoride (PVDF) microfiltration membrane was used in the method for its ability to reversibly and specifically bind IgG antibodies from antiserum samples by hydrophobic interaction. Using this form of selective antibody binding and enrichment an affinity membrane with antigen binding ability was obtained in-situ. This was done by passing a pulse of diluted antiserum sample through a stack of microporous PVDF membranes. The affinity membrane thus formed was challenged with a pulse of antigen solution and the amount of antigen bound was accurately determined using chromatographic methods. The antigen binding correlated well with the antibody loading on the membrane. This method is direct, rapid and accurate, does not involve any chemical reaction, and uses very few reagents. Moreover, the same membrane could be repeatedly used for sequential immunoassays on account of the reversible nature of the antibody binding. Proof of concept of this method is provided using human hemoglobin as model antigen and rabbit antiserum against human hemoglobin as the antibody source. 相似文献
13.
Qing-Yun Wu Feng Li Xiao-Yun Wang 《International journal of biological macromolecules》2009,45(4):393-398
Arginine kinase, a member of phosphagen kinase, is a key enzyme in the cellular energy metabolism of invertebrates. A series mutation of conserved amino acid residue V65 was constructed to investigate its role in AK substrate synergism, structural stability and activity. Our study revealed that mutation in this conserved site could cause pronounced loss of activity, conformational changes and distinct substrate synergism alteration. Spectroscopic experiments indicated that these mutations influenced transition from the molten globule intermediate to the native state in folding process. These results provided herein suggest that amino acid residue V65 played a relatively important role in AK substrate synergism, structural stability and activity. 相似文献
14.
目的应用假病毒中和法建立检测血清HPV16/18中和抗体滴度检测方法并进行验证。方法分别采用不同批次假病毒以及不同代次细胞对不同滴度的HPV16/18阳性血清进行多次平行检测,考察这些因素对检验结果的影响;同时通过对抗HPV16/18双价阳性血清、抗HPV16单价阳性血清和抗HPV18单价阳性血清的检测进一步评估中和抗体检测法的准确性、特异性及重复性。结果不同批次假病毒和不同代次细胞对检验结果的影响均在4倍范围内,此外该检测法的准确性、特异性、重复性均在可接受标准范围之内。结论建立的假病毒法可满足中和抗体效价检测的要求,可用于评价疫苗的免疫效果。 相似文献
15.
Kangseung Lee Se-Hui Jung Deok-Hoon Kong Byeong-Moon Hwang Eun-Taek Han Seoung-Woo Park Jae Hyo Park Young-Myeong Kim Kwon-Soo Ha 《Journal of biotechnology》2013
The development of molecular probes is a prerequisite for activity-based protein profiling. This strategy helps in characterizing the catalytic activity and function of proteins, and how these proteins and protein complexes control biological processes of interest. These probes are composed of a reactive functional group and a reporter tag. The reactive group of these substrate probes has been considered to be important to their design, while the significance of the reporter tag is relatively underestimated. In this study we compare TAMRA-cadaverine and biotin-cadaverine, two substrate probes that have different reporter tags but an identical reactive functional group. We assess the on-chip transamidating activity of two transglutaminases; transglutaminase 2 and blood coagulation factor XIII. Activity assays were more easily executed when using the direct probe TAMRA-cadaverine. However the indirect probe, biotin-cadaverine, provided a wider dynamic range, higher signal-to-noise ratio, and lower limit of detection compared to TAMRA-cadaverine. Additionally, we successfully used the on-chip activity assay using the indirect probe to determine TG2 and FXIII activities in Hela cell lysates and human plasma samples, respectively. These results demonstrate that the reporter tag of the substrate probe is critical for protocol execution, sensitivity, and dynamic range of enzyme activity assays. Furthermore, this study provides a helpful guide for development of new probes, which is necessary for the identification of potential biomarkers and therapeutic targets for treating enzyme-related diseases. 相似文献
16.
Validation of a sensitive assay for thiocoraline in mouse plasma using liquid chromatography-tandem mass spectrometry 总被引:2,自引:0,他引:2
Yin J Aviles P Lee W Ly C Guillen MJ Calvo P Manzanares I Faircloth G 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2003,794(1):89-98
A sensitive high-performance liquid chromatography-tandem mass spectrometry assay for thiocoraline, an anti-tumor depsipeptide, in mouse plasma is described. Echinomycin, a quinoxaline peptide, was used as an internal standard. Thiocoraline was recovered from the mouse plasma using protein precipitation with acetonitrile and followed by solid-phase extraction of the supernatant. The mobile phase consisted of methanol (0.1% formic acid)-water (0.1% formic acid) (90:10, v/v). The analytical column was a YMC C(18). The standard curve was linear from 0.1 to 50 ng/ml (R(2)>0.99). The lower limit of quantitation was 0.1 ng/ml. The assay was specific based on the multiple reaction monitoring transitions at m/z 1157-->215 and m/z 1101-->243 for thiocoraline and the internal standard, echinomycin, respectively. The mean intra- and inter-day assay accuracies remained below 5 and 12%, respectively, for all calibration standards and quality control (QC) samples. The intra- and inter-day assay precisions were less than 11.4 and 9.5% for all QC levels, respectively. The utility of the assay was demonstrated by a pharmacokinetic study of i.v. (bolus) thiocoraline on CD-1 mice. Thiocoraline was stable in mouse plasma in an ice-water bath for 6 h and for three freeze-thaw cycles. The reconstituted thiocoraline after extraction and drying sample process was stable in the autosampler for over 24 h. The assay was able to quantify thiocoraline in plasma up to 48 h following dose. Pharmacokinetic analysis showed that thiocoraline has distinct pharmacokinetic profiling when dosed in different formulation solutions. The assay is currently used to measure thiocoraline plasma concentrations in support of a project to develop a suitable formulation with a desirable pharmacokinetic profile. 相似文献
17.
We have developed a fibrinogen-specific sandwich enzyme-linked immunosorbent assay (ELISA) microarray assay for use in qualitatively distinguishing between blood plasma and serum samples. Three capture antibodies (49D2, HPA001900, and F8512) were evaluated in conjunction with 1D6 as the detection antibody. The data show that 49D2 and (to a lesser extent) F8512 successfully identify previously unknown plasma and serum samples based on approximately a 28-fold difference in signal intensity between the sample types. This assay has utility in rapidly identifying previously archived clinical samples with incomplete annotation in a high-throughput manner prior to proteomic analyses. 相似文献
18.
Purification of prostaglandin H synthetase and a fluorometric assay for its activity 总被引:1,自引:0,他引:1
Prostaglandin H synthetase (PGH synthetase) has been purified to homogeneity from sheep vesicular glands. The pure enzyme has a specific activity of about 40 microM of arachidonic acid consumed per minute per milligram of protein, which corresponds to a turnover number of 2800 min-1 per subunit. The purified enzyme was obtained by one-stage chromatography on DEAE-Toyopearl 650 from Tween 20-solubilized microsomes. A sensitive fluorometric assay for PGH synthetase activity using homovanillic acid (HVA) as electron donor has been proposed. It has been shown that homovanillic acid may be used as the electron donor and that in the presence of HVA the enzyme has an activity of approximately 40 microM/min/mg. 相似文献
19.
Marcotte PA Richardson PL Richardson PR Guo J Barrett LW Xu N Gunasekera A Glaser KB 《Analytical biochemistry》2004,332(1):90-99
A novel fluorescent substrate was devised for the sirtuin (SIRT) class of human protein deacetylases comprised of a peptide sequence containing a single acetyl-lysine residue, with a fluorescent group (tetramethylrhodamine-6-carboxylic acid, 6-TAMRA) near the carboxyl terminus and a nonfluorescent quenching group (QSY-7) near the amino terminus. The peptide sequence is modeled after the p53 acetylation site but is unreactive toward trypsin because all other lysine and arginine residues have been replaced by serine. However, the SIRT-deacetylated peptide is readily cleaved by trypsin, resulting in a maximal 30-fold enhancement of the 6-TAMRA fluorescence. Nicotinamide at millimolar concentrations stops the deacetylation but does not inhibit trypsin, and a microtiter plate assay of the SIRTs has been devised using the fluorescent substrate and these reagents. Using this method, the kinetics of the reaction of the cosubstrate nicotinamide adenine dinucleotide and the competitive inhibitor nicotinamide with SIRT1 and SIRT2 has been analyzed. Several nicotinamide analogs have also been tested as inhibitors and found to have much lower affinity for these enzymes than does the parent compound. 相似文献
20.
Abstract: Wildlife population models are potentially valuable for conservation planning. Validation is necessary to ensure that models are sufficiently robust for predicting management outcomes consistent with conservation objectives. Sorensen et al. (2008) produced a model of woodland caribou (Rangifer tarandus) population growth rate that was recently modified and used as a predictive tool at several scales. We computed confidence intervals and evaluated the performance of this model using novel data. Confidence intervals were wide, and results suggested that the model may have a positive bias, resulting in over-estimation of population growth rates, as well as low predictive power. Wide confidence intervals mean that current understanding of factors governing woodland caribou herd dynamics is not sufficient for wildlife managers to make reliable projections of responses to management. 相似文献