首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A multiplex PCR procedure that detects six major virulence genes, fliC, stx1, stx2, eae, rfbE, and hlyA, in Escherichia coli O157:H7 was developed. Analyses of the available sequences of the six major virulence genes and the published primers allowed us to develop the six-gene, multiplex PCR protocol that maintained the specificity of each primer pair. The resulting six bands for fliC, stx1, stx2, eae, rfbE, and hlyA were even and distinct with product sizes of 949, 655, 477, 375, 296, and 199 bp, respectively. The procedure was validated with a total of 221 E. coli strains that included 4 ATCC, 84 cattle, and 57 human E. coli O157:H7 strains as well as 76 non-O157 cattle and human E. coli strains. The results of all 221 strains were similar to the results generated by established multiplex PCR methods that involved two separate reactions to detect five virulence genes (stx1, stx2, eae, fliC, and hlyA). Specificity of the O antigen was indicated by amplification of only O157, and not O25, O26, O55, O78, O103, O111, O127, and O145 E. coli serotypes. Sensitivity tests showed that the procedure amplified genes from a fecal sample spiked with a minimum of 104 CFU/g (10 cells/reaction) of E. coli O157. After a 6-h enrichment of E. coli O157-spiked samples, a sensitivity level of 10 CFU/g was achieved.  相似文献   

2.
AIMS: Combinations of PCR primer sets were evaluated to establish a multiplex PCR method to specifically detect Escherichia coli O157:H7 genes in bovine faecal samples. METHODS AND RESULTS: A multiplex PCR method combining three primer sets for the E. coli O157:H7 genes rfbE, uidA and E. coli H7 fliC was developed and tested for sensitivity and specificity with pure cultures of 27 E. coli serotype O157 strains, 88 non-O157 E. coli strains, predominantly bovine in origin and five bacterial strains other than E. coli. The PCR method was very specific in the detection of E. coli O157:H7 and O157:H- strains, and the detection limit in seeded bovine faecal samples was <10 CFU g(-1) faeces, following an 18-h enrichment at 37 degrees C, and could be performed using crude DNA extracts as template. CONCLUSIONS: A new multiplex PCR method was developed to detect E. coli O157:H7 and O157:H-, and was shown to be highly specific and sensitive for these strains both in pure culture and in crude DNA extracts prepared from inoculated bovine faecal samples. SIGNIFICANCE AND IMPACT OF THE STUDY: This new multiplex PCR method is suitable for the rapid detection of E. coli O157:H7 and O157:H- genes in ruminant faecal samples.  相似文献   

3.
AIMS: Developing and evaluating a rapid real-time polymerase chain reaction (PCR) method for the identification of Escherichia coli O157:H7 in cattle and dairy wastewater samples produced from mozzarella cheese factories, without pre-enrichment step before DNA extraction. METHODS AND RESULTS: Wastewater samples were collected from a dairy farm producing mozzarella cheese and located in Puglia (south of Italy). Plate count and other microbial assays were performed 1 h after sampling. Wastewater samples were artificially inoculated with 10(4), 10(7) and 10(8) cells ml(-1) of E. coli O157:H7, strain EDL933. PCR protocols for stx1, stx2 and eae genes were first tested on pure DNA extracted from type strains, in order to optimize the amplification conditions and reagent concentration before real-time PCR experiments. Three specific fragments of ca 106, 150 and 200 bp corresponding to genes eae, stx1 and stx2, respectively, were obtained. Real-time PCR experiments were performed with DNA extracted from dairy and manure wastewater samples inoculated with 10(4), 10(7) and 10(8) colony-forming units (CFU) ml(-1) of E. coli O157:H7 strain EDL 933. The sensitivity limit of the assay was 10(-1) pg microl(-1) for eae, stx2 and 16SrRNA, and 1 pg microl(-1) for stx1 gene respectively. CONCLUSIONS: A real-time PCR protocol has been developed and used in order to identify potential pathogens in dairy wastewater, in which previous methods (including standard PCR) failed to work. SIGNIFICANCE AND IMPACT OF THE STUDY: Cattle and dairy wastewater samples produced from mozzarella cheese factories may harbour verocytotoxin-producing E. coli. The availability of rapid and sensitive molecular methods may be useful to monitor the persistence of verocytotoxin-producing E. coli in general and to assess the effectiveness of wastewater treatments.  相似文献   

4.
5.
以编码大肠杆菌O157抗原的rfbE基因、 编码H7抗原的fliC基因以及编码毒力因子的eaeA基因为靶基因, 选择3对引物, 建立并优化了检测大肠杆菌O157:H7的多重PCR体系, 扩增产物分别为291 bp、625 bp、368 bp, 采用30株细菌验证了该多重PCR具有特异性。PCR检测的灵敏度在DNA水平上达到91.35 pg; 在存在干扰菌鼠伤寒沙门氏菌(Salmonella?typhimurium)的情况下, 当起始污染量为1.4 CFU/mL时, 37 ℃培养6 h 即可检出。在30份肉类样品中, 有3份检出了大肠杆菌O157:H7。本研究建立的多重PCR方法可特异、灵敏地实现对大肠杆菌O157:H7的检测。  相似文献   

6.
肉类中大肠杆菌O157:H7多重PCR检测方法的建立   总被引:3,自引:0,他引:3  
以编码大肠杆菌 O157 抗原的 rfbE 基因、编码 H7 抗原的 fliC 基因以及编码毒力因子的eaeA 基因为靶基因,选择3对引物,建立并优化了检测大肠杆菌 O157:H7 的多重 PCR 体系,扩增产物分别为291 bp、625 bp,368 bp,采用30株细菌验证了该多重 PCR 具有特异性.PCR 检测的灵敏度在 DNA 水平上达到91.35 Pg;在存在干扰菌鼠伤寒沙门氏(Salmonella typhimurium)的情况下,当起始污染量为1.4 CFU/mL时,37℃培养6 h即可检出.在30份肉类样品中,有3份检出了大肠杆菌 O157:H7.本研究建立的多重 PCR 方法可特异、灵敏地实现对大肠杆菌 O157:H7 的检测.  相似文献   

7.
Direct PCR detection of Escherichia coli O157:H7   总被引:2,自引:0,他引:2  
AIMS: This paper reports a simple, rapid approach for the detection of Shiga toxin (Stx)-producing Escherichia coli (STEC). METHODS AND RESULTS: Direct PCR (DPCR) obviates the need for the recovery of cells from the sample or DNA extraction prior to PCR. Primers specific for Stx-encoding genes stx1 and stx2 were used in DPCR for the detection of E. coli O157:H7 added to environmental water samples and milk. CONCLUSIONS: PCR reactions containing one cell yielded a DPCR product. SIGNIFICANCE AND IMPACT OF THE STUDY: This should provide an improved method to assess contamination of environmental and other samples by STEC and other pathogens.  相似文献   

8.
针对大肠杆菌O157:H7(Escherichia coli O157:H7,E.coli O157:H7)传统检测方法检测周期长的问题,建立了肉类中的E.coli O157:H7的改良环介导等温扩增(LAMP)快速检测方法。以E.coli O157:H7的O157特异性抗原rfbE基因、鞭毛H7特异性抗原fliC基因序列作为靶序列,分别设计2套增加了环引物的改良LAMP引物序列,单管同时检测,通过肉眼观察白色沉淀,判断检测结果。采用36株细菌验证了该改良LAMP引物的特异性。热裂解法提取的DNA经改良LAMP体系扩增20 min,检测E.coli O157:H7的灵敏度为1.4 CFU/mL,人工污染肉中的E.coli O157:H7检出限为1.8 CFU/g。137份实样中,检测出1份E.coli O157:H7假阳性,与行业标准SNT0973-2000符合率达到99.3%。  相似文献   

9.
Listeriosis is a serious food-borne infection with mortality rates approaching 30%. Therefore, the rapid, cost-effective, and automated detection of Listeria monocytogenes throughout the food chain continues to be a major concern. Here we describe three novel quantitative real-time PCR assays for L. monocytogenes based on amplification of a target hlyA gene with SYBR Green I chemistry and hydrolysis probe (TaqMan MGB probe). In order to offer sensitive, rapid and robust tool of additional economical value the real-time PCR assays were designed and optimized to only 5 μl-reactions. All assays were evaluated by using different non-reference Listeria strains isolated from various food matrices. Results demonstrated specificity to L. monocytogenes with accurate quantification over a dynamic range of 5-6 log units with R2 higher than 0.98 and amplification efficiencies reaching above 92%. The detection and quantification limits were as low as 165 genome equivalents. Comparison of novel assays to commercially available TaqMan® Listeria monocytogenes Detection Kit and previously published studies revealed similar specificity, sensitivity and efficiency, but greater robustness and especially cost-efficiency in the view of smaller reaction volumes and continuous increase in sample throughput.  相似文献   

10.
Escherichia coli O157:H7 has been associated with water related outbreaks. It has been isolated from surface and ground waters. It is capable of survival in water for days to weeks  相似文献   

11.
This study was attempted to develop a new exponential sum model to describe the effect of temperature on growth rate (GR) of Escherichia coli O157:H7 in broth. The growth rates of E. coli O157:H7 at different storage temperatures (4, 10, 15, 20, 25, 30, and 35°C) estimated by fitting with the modified Gompertz model were used to develop secondary models such as square root model, Ratkowsky model and exponential sum model. Measures of coefficient of determination (R 2), root mean square error (RMSE) and the sum of squares due to error (SSE) were employed to compare the performances of these three secondary models. Based on these criteria, the developed exponential sum model showed the better goodness-of-fit and performance.  相似文献   

12.
Three pathogens, Riemerella anatipestifer, Escherichia coli, and Salmonella enterica, are leading causes of bacterial fibrinous pericarditis and perihepatitis in ducks in China and worldwide. It is difficult to differentiate these pathogens when obtaining a diagnosis on clinical signs and pathological changes. The aim of this research was to develop a multiplex polymerase chain reaction (m-PCR) that could discriminate R. anatipestifer, E. coli, and S. enterica rapidly in field isolates, or detect the three bacteria in clinical samples from diseased ducks. We selected the DnaB helicase (dnaB) gene of R. anatipestifer, alkaline phosphatase (phoA) gene of E. coli and invasion protein (invA) gene of S. enterica as target genes. In optimized conditions, the limitation of detection was approximately 103 colony forming units (CFU) of each of these three bacterial pathogens per PCR reaction tube. The m-PCR method showed specific amplification of respective genes from R. anatipestifer, E. coli, and S. enterica. Using the m-PCR system, bacterial strains isolated from diseased ducks in our laboratory were categorized successfully, and the pathogens could also be detected in clinical samples from diseased ducks. Therefore, the m-PCR system could distinguish the three pathogens simultaneously, for identification, routine molecular diagnosis and epidemiology, in a single reaction.  相似文献   

13.
Aims: The aim of this study was to develop and optimize a novel method that combines ethidium bromide monoazide (EMA) staining with real‐time PCR for the detection of viable Escherichia  coli O157:H7 in ground beef. EMA can penetrate dead cells and bind to intracellular DNA, preventing its amplification via PCR. Methods and Results: Samples were stained with EMA for 5 min, iced for 1 min and exposed to bright visible light for 10 min prior to DNA extraction, to allow EMA binding of the DNA from dead cells. DNA was then extracted and amplified by TaqMan® real‐time PCR to detect only viable E. coli O157:H7 cells. The primers and TaqMan® probe used in this study target the uidA gene in E. coli O157:H7. An internal amplification control (IAC), consisting of 0·25 pg of plasmid pUC19, was added in each reaction to prevent the occurrence of false‐negative results. Results showed a reproducible application of this technique to detect viable cells in both broth culture and ground beef. EMA, at a final concentration of 10 μg ml?1, was demonstrated to effectively bind DNA from 108 CFU ml?1 dead cells, and the optimized method could detect as low as 104 CFU g?1 of viable E. coli O157:H7 cells in ground beef without interference from 108 CFU g?1 of dead cells. Conclusions: EMA real‐time PCR with IAC can effectively separate dead cells from viable E. coli O157:H7 and prevent amplification of DNA in the dead cells. Significance and Impact of the Study: The EMA real‐time PCR has the potential to be a highly sensitive quantitative detection technique to assess the contamination of viable E. coli O157:H7 in ground beef and other meat or food products.  相似文献   

14.
Enterohemorrhagic Escherichia coli (EHEC) are a physiologically, immunologically and genetically diverse collection of strains that pose a serious water-borne threat to human health. Consequently, immunological and PCR assays have been developed for the rapid, sensitive detection of presumptive EHEC. However, the ability of these assays to consistently detect presumptive EHEC while excluding closely related non-EHEC strains has not been documented. We conducted a 30-month monitoring study of a major metropolitan watershed. Surface water samples were analyzed using an immunological assay for E. coli O157 (the predominant strain worldwide) and a multiplex PCR assay for the virulence genes stx(1), stx(2) and eae. The mean frequency of water samples positive for the presence of E. coli O157, stx(1) or stx(2) genes, or the eae gene was 50%, 26% and 96%, respectively. Quantitative analysis of selected enriched water samples indicated that even in samples positive for E. coli O157 cells, stx(1)/stx(2) genes, and the eae gene, the concentrations were rarely comparable. Seventeen E. coli O157 strains were isolated, however, none were EHEC. These data indicate the presence of multiple strains similar to EHEC but less pathogenic. These findings have important ramifications for the rapid detection of presumptive EHEC; namely, that current immunological or PCR assays cannot reliably identify water-borne EHEC strains.  相似文献   

15.
We present a method for instant DNA extraction fromArabidopsis thaliana based on a simple DNA extraction method (Edwards et al., 1991). A piece of rosette leaf (typically 3–5 mg) was ground in a centrifuge tube in extraction solution. Extracted DNA was suitable for PCR analysis, without centrifugation. The feasibility of this method was confirmed by testing 24 primer sets. This method requires less than 1 mg of plant tissue and is useful for genetic mapping, transgene detection, and other experiments.  相似文献   

16.

Introduction

Acquired AmpC enzymes, classified as miscellaneous extended-spectrum β-lactamase (ESBLM) enzymes according to a recently proposed β-lactamase classification, are increasing according to several publications. Simple and rapid methods for detection of ESBLM are needed for appropriate infection control. A gel-based multiplex PCR method for acquired blaAmpC detection and subtype classification has been available for several years. Here, we describe a modification of the protocol to suit real-time PCR platforms and to include novel genotypes.

Material and methods

Clinical isolates with clavulanic acid non-reversible non-susceptibility to extended-spectrum cephalosporins were subjected to combination disk testing with cefoxitin +/− cloxacillin at Malmö University Hospital. Phenotypical AmpC production was defined as cloxacillin reversible cefoxitin resistance. In this study 51 phenotypical AmpC-producing isolates, were subjected to the acquired blaAmpC real-time PCR assay. The acquired blaAmpC positive isolates were further characterized by DNA sequencing of the acquired AmpC encoding gene, Pulsed-Field Gel Electrophoresis (PFGE) and PCR-based replicon typing.

Results and discussion

The real-time PCR assay was able to detect and sub-classify all acquired blaAmpC genes described to date. The assay can be performed in less than 3 h, including pre-PCR preparations. Analysis of the isolate collection resulted in 18 of 51 phenotypical AmpC-producing isolates being positive in the acquired blaAmpC real-time multiplex PCR assay; 17 of subtype CIT and one DHA. Sequence analysis identified 16 isolates as blaCMY-2, one as blaCMY-16 and one as blaDHA-1. Detected plasmid replicon types were I1 and B/O. Two of the E. coli isolates were identical according to PFGE and the others were unrelated.  相似文献   

17.
Escherichia coli O157:H7 is an important pathogenic Bacterium that threatens human health. A convenient, sensitive and specific method for the E. coli O157:H7 detection is necessary. We developed two pairs of monoclonal antibodies through traditional hybridoma technology, one specifically against E. coli O157 antigen and the other specifically against E. coli H7 antigen. Using these two pairs of antibodies, we developed two rapid test kits to specifically detect E. coli O157 antigen and E. coli H7 antigen, respectively. The detection sensitivity for O157 positive E. coli is 1 × 103 CFU per ml and for H7 positive E. coli is 1 × 104 CFU per ml. Combining these two pairs of antibodies together, we developed a combo test strip that can specifically detect O157: H7, with a detection sensitivity of 1 × 104 CFU per ml, when two detection lines are visible to the naked eye. This is currently the only rapid detection reagent that specifically detects O157: H7 by simultaneously detecting O157 antigen and H7 antigens of E. coli. Our product has advantages of simplicity and precision, and can be a very useful on-site inspection tool for accurate and rapid detection of E. coli O157:H7 infection.  相似文献   

18.
ε-Poly-l-lysine (ε-PL)2 is widely used as an antibacterial agent because of its broad antimicrobial spectrum. However, the mechanism of ε-PL against pathogens at the molecular level has not been elucidated. This study investigated the antibacterial activity and mechanism of ε-PL against Escherichia coli O157:H7 CMCC44828. Propidium monoazide-PCR test results indicated that the threshold condition of ε-PL for complete membrane lysis of E. coli O157:H7 was 10 μg/mL (90% mortality for 5 μg/mL). Further verification of the destructive effect of ε-PL on cell structure was performed by atomic force microscopy and transmission electron microscopy. Results showed a positive correlation between reactive oxygen species (ROS) 3 levels and ε-PL concentration in E. coli O157:H7 cells. Moreover, the mortality of E. coli O157:H7 was reduced when antioxidant N-acetylcysteine was added. Results from real-time quantitative PCR (RT-qPCR) 4 indicated that the expression levels of oxidative stress genes sodA and oxyR were up-regulated 4- and 16-fold, respectively, whereas virulence genes eaeA and espA were down-regulated after ε-PL treatment. Expression of DNA damage response (SOS response) 5 regulon genes recA and lexA were also affected by ε-PL. In conclusion, the antibacterial mechanism of ε-PL against E. coli O157:H7 may be attributed to disturbance on membrane integrity, oxidative stress by ROS, and effects on various gene expressions, such as regulation of oxidative stress, SOS response, and changes in virulence.  相似文献   

19.
周杨 《微生物学通报》2017,44(8):1996-2004
【目的】评价基于环介导恒温扩增技术(LAMP)的大肠杆菌O157:H7(Escherichia coli O157:H7)快速检测试剂盒的实效性。【方法】测定快速检测试剂盒的特异性、灵敏度、重复性、保质期以及运输稳定性,并与传统方法对比检测实际样品。【结果】大肠杆菌O157:H7标准菌株样品均检测为阳性,非大肠杆菌O157:H7标准菌株样品均检测为阴性,未发现有交叉反应;试剂盒最低检验限为29 CFU;该试剂盒的特异性、灵敏度及准确度与传统方法相比具有较高的一致性;试剂盒对高菌量目标菌和阴性菌样品的检测重复率均为100%,对低菌量目标菌样品的批间检测重复率为94%。试剂盒可在4°C保存9个月以上,并且可进行变温储存72 h以上。【结论】该试剂盒特异性好,灵敏度高,重复性好,储存方便,检测结果稳定、可靠,适用于对食品中大肠杆菌O157:H7的检测需求。  相似文献   

20.
A disposable amperometric immunosensing strip was fabricated for rapid detection of Escherichia coli O157:H7. The method uses an indirect sandwich enzyme-linked immunoassay with double antibodies. Screen-printed carbon electrodes (SPCEs) were framed by commercial silver and carbon inks. For electrochemical characterization the carbon electrodes were coupled with the first E. coli O157:H7-specific antibody, E. coli O157:H7 intact cells and the second E. coli O157:H7-specific antibody conjugated with horseradish peroxidase (HRP). Hydrogen peroxide and ferrocenedicarboxylic acid (FeDC) were used as the substrate for HRP and mediator, respectively, at a potential +300 mV vs. counter/reference electrode. The response current (RC) of the immunosensing strips could be amplified significantly by 13-nm diameter Au nanoparticles (AuNPs) attached to the working electrode. The results show that the combined effects of AuNPs and FeDC enhanced RC by 13.1-fold. The SPCE immunosensing strips were used to detect E. coli O157:H7 specifically. Concentrations of E. coli O157:H7 from 10(2) to 10(7)CFU/ml could be detected. The detection limit was approximately 6CFU/strip in PBS buffer and 50CFU/strip in milk. The SPCE modified with AuNPs and FeDC has the potential for further applications and provides the basis for incorporating the method into an integrated system for rapid pathogen detection.  相似文献   