首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The Micromass Platform LCZ mass detector parameters were optimized for simultaneous recording of the protonated (CsA∼H+), sodium adduct (CsA∼Na+) and potassium adduct (CsA∼K+) of cyclosporin A eluted from a Symmetry Shield RP8 column. The optimized procedure allows a precise analysis of CsA in whole blood or serum without removal of salts prior to analysis. The ratio of the three forms of CsA varied depending on the assay condition and the types of specimens being analyzed. The summation of three ionic forms of CsA detected by LC–ESI-MS is a reliable and simple method to assess CsA concentration in the blood.  相似文献   

2.
Quantitative analysis of two opioid peptides, DSLET [(d-Ser2)Leu-enkephalin-Thr6] and Met-enkephalin-Arg-Gly-Leu, was performed using microbore liquid chromatography interfaced to electrospray ionization tandem mass spectrometry. Validation of the methodology was demonstrated for each peptide in plasma. Quantitative analyses were performed through the use of a deuterium labelled peptide analog as an internal standard. Linearity was observed for the analysis of DSLET (5–1000 ng/ml) and Met-enkephalin-Arg-Gly-Leu (1–1000 ng/ml) in plasma with a limit of detection of 0.25 ng/ml for Met-enkephalin-Arg-Gly-Leu and 1.0 ng/ml for DSLET. In general, the observed concentrations showed good reproducibility with coefficients of variation of within 15%. In the concentration range studied, only 0.5 ml of plasma was required for optimal detection of Met-enkephalin-Arg-Gly-Leu and 0.25 ml for DSLET. Application of this method was demonstrated by studying the disposition of DSLET in a rat. DSLET administered to a rat exhibited a short half-life and a high clearance value.  相似文献   

3.
A sensitive and specific assay of imidapril and its active metabolite, imidaprilat, in human plasma has been developed. This method is based on rapid isolation and high-performance liquid chromatography (HPLC)–electrospray ionization (ESI)-tandem mass spectrometry (MS–MS). Imidapril and imidaprilat were isolated from human plasma using OASIS HLB (solid-phase extraction cartridge), after deproteinization. The eluent from the cartridge was evaporated to dryness, and the residue was reconstituted in mobile phase and injected into the HPLC–ESI-MS–MS system. Each compound was separated on a semi-micro ODS column in acetonitrile–0.05% (v/v) formic acid (1:3, v/v). The selected ion monitoring using precursor→product ion combinations of m/z 406→234 and 378→206, was used for determination of imidapril and imidaprilat, respectively. The linearity was confirmed in the concentration range of 0.2 to 50 ng/ml in human plasma, and the precision of this assay, expressed as a relative standard deviation, was less than 13.2% over the entire concentration range with adequate assay accuracy. The HPLC–ESI-MS–MS method correlates well with the radioimmunoassay method, therefore, it is useful for the determination of imidapril and imidaprilat with sufficient sensitivity and specificity in clinical studies.  相似文献   

4.
We describe a novel high performance liquid chromatography–electrospray ionization mass spectrometry (HPLC–ESI-MS) method for the simultaneous quantification of enzymatic immature (dihydroxylysinonorleucine DHLNL, hydroxylysinonorleucine HLNL) and mature (pyridinoline PYD, deoxypyridinoline DPD) collagen crosslinks in connective tissues. The crosslinks were separated on a C18 Atlantis® T3 reversed-phase column with heptafluorobutyric acid (HFBA) as volatile ion-pairing reagent in an acetonitrile–water mobile phase. Detection was carried out by electrospray ionization mass spectrometry in a positive ion mode with selected ion recording (SIR). This method is more sensitive and selective than ion exchange chromatography with post-column ninhydrin detection which is the reference method used for the simultaneous quantification of collagen enzymatic divalent and trivalent crosslinks. The intra and inter-day precision errors were less than 3.4 and 7.7%, respectively for DHLNL, 3.5 and 5.9%, respectively for HLNL, 4.0 and 5.2%, respectively for PYD, 8.2 and 10.7%, respectively for DPD. This novel technique should be useful to quantify simultaneously DHLNL, HLNL, PYD and DPD in connective tissues and to evaluate the maturation of collagen by determination of the ratio between immature and mature enzymatic crosslinks.  相似文献   

5.
Trichloroethylene (TCE), a major occupational and environmental pollutant, has been recently associated with aberrant epigenetic changes in experimental animals and cultured cells. TCE is known to cause severe hepatotoxicity; however, the association between epigenetic alterations and TCE-induced hepatotoxicity are not yet well explored. DNA methylation, catalyzed by enzymes known as DNA methyltransferases (DNMT), is a major epigenetic modification that plays a critical role in regulating many cellular processes. In this study, we analyzed the TCE-induced effect on global DNA methylation and DNMT enzymatic activity in human hepatic L-02 cells. A sensitive and quantitative method combined with liquid chromatography and electrospray ionization tandem mass spectrometry (LC–ESI-MS/MS) was validated and utilized for assessing the altered DNA methylation in TCE-induced L-02 cells. Quantification was accomplished in multiple reaction monitoring (MRM) mode by monitoring a transition pair of m/z 242.1 (molecular ion)/126.3 (fragment ion) for 5-mdC and m/z 268.1/152.3 for dG. The correlation coefficient of calibration curves between 5-mdC and dG was higher than 0.9990. The intra-day and inter-day relative standard derivation values (RSD) were on the range of 0.53–7.09% and 0.40–2.83%, respectively. We found that TCE exposure was able to significantly decrease the DNA methylation and inhibit DNMT activity in L-02 cells. Our results not only reveal the association between TCE exposure and epigenetic alterations, but also provide an alternative mass spectrometry-based method for rapid and accurate assessment of chemical-induced altered DNA methylation in mammal cells.  相似文献   

6.
In order to discriminate selegiline (SG) use from methamphetamine (MA) use, the urinary metabolites of SG users have been investigated using high-performance liquid chromatography (HPLC)–electrospray ionization mass spectrometry (HPLC–ESI–MS). Selegiline-N-oxide (SGO), a specific metabolite of SG, was for the first time detected in the urine, in addition to other metabolites MA, amphetamine (AP) and desmethylselegiline (DM-SG). A combination of a Sep-pak C18 cartridge for the solid-phase extraction, a semi-micro SCX column (1.5 mm I.D.×150 mm) for HPLC separation and ESI–MS for detection provided a simple and sensitive procedure for the simultaneous determination of these analytes. Acetonitrile–10 mM ammonium formate buffer adjusted to pH 3.0 (70:30, v/v) at a flow-rate of 0.1 ml/min was found to be the most effective mobile phase. Linear calibration curves were obtained over the concentration range from 0.5 to 100 ng/ml for all the analytes by monitoring each protonated molecular ion in the selected ion monitoring (SIM) mode. The detection limits ranged from 0.1 to 0.5 ng/ml. Upon applying the scan mode, 10–20 ng/ml were the detection limits. Quantitative investigation utilizing this revealed that SGO was about three times more abundant (47 ng/ml, 79 ng/ml) than DM-SG in two SG users’ urine samples tested here. This newly-detected, specific metabolite SGO was found to be an effective indicator for SG administration.  相似文献   

7.
Lysophosphatidic acid (LPA) is a lipid mediator with multiple biological functions. A highly selective and sensitive liquid chromatography–tandem mass spectrometry (LC/MS/MS) method was developed for the determination of LPAs (16:0 LPA, 18:0 LPA, 18:1 LPA, 20:4 LPA) in rat brain cryosections. After partitioning the LPAs from other lipophilic material present in the tissue with a liquid–liquid extraction, a reversed-phase column and ion pair technique was used for separating analytes with a gradient elution. An internal standard (17:0 LPA) was included in the analysis. Detection and quantification of the LPAs were carried out with a triple quadrupole mass spectrometer using negative electrospray ionization (ESI) and multiple reaction monitoring (MRM). The artificial formation of LPAs from lysophosphatidylcholines during the sample preparation procedure and instrumentation was carefully studied during the method development. The method was validated; acceptable selectivity, accuracy, precision, recovery, and stability were obtained for concentrations within the calibration curve range of 0.02–1.0 μM for LPAs. The quantification limit of the assay was 54 fmol injected into column for each LPAs. The method was applied to comparative studies of LPA levels in rat brain cryosections after the various chemical pre-treatments of the sections.  相似文献   

8.
Thyrotropin-releasing hormone (TRH) is involved in a wide range of biological responses. It has a central role in the endocrine system and regulates several neurobiological activities. In the present study, a rapid, sensitive and selective liquid chromatography–mass spectrometry method for the identification and quantification of TRH has been developed. The methodology takes advantage of the specificity of the selected-ion monitoring acquisition mode with a limit of detection of 1 fmol. Furthermore, the MS/MS fragmentation pattern of TRH has been investigated to develop a selected reaction monitoring (SRM) method that allows the detection of a specific b2 product ion at m/z 249.1, corresponding to the N-terminus dipeptide pyroglutamic acid–histidine. The method has been tested on rat hypothalami to evaluate its suitability for the detection within very complex biological samples.  相似文献   

9.
We first detected glutathionyl hemoglobin (Hb) β-chain in hemodialysis patients and healthy subjects using electrospray ionization liquid chromatography–mass spectrometry. The ratio of glutathionyl Hb β-chain to total β-chain was markedly increased in the hemodialysis patients as compared with healthy subjects. Glutathionyl Hb will be used as a new clinical marker of oxidative stress.  相似文献   

10.
The drug combination rifampicin and clarithromycin is used in regimens for infections caused by Mycobacteria. Rifampicin is a CYP3A4 inducer while clarithromycin is known to inhibit CYP3A4. During combined therapy rifampicin concentrations may increase and clarithromycin concentrations may decrease. Therefore a simple, rapid and easy method for the measurement of the blood concentrations of these drugs and their main metabolites (14-hydroxyclarithromycin and 25-desacetylrifampicin) is developed to evaluate the effect of the drug interaction. The method is based on the precipitation of proteins in human serum with precipitation reagent containing the internal standard (cyanoimipramine) and subsequently high-performance liquid chromatography (HPLC) analysis and tandem mass spectrometry (MS/MS) detection in an electron positive mode. The method validation included selectivity, linearity, accuracy, precision, dilution integrity, recovery and stability according to the “Guidance for Industry – Bioanalytical Method Validation” of the FDA. The calibration curves were linear in the range of 0.10–10.0 mg/L for clarithromycin and 14-hydroxyclarithromycin and 0.20–5.0 mg/L for rifampicin and 25-desacetylrifampicin, with within-run and between-run precisions (CVs) in the range of 0% to ?10%. The components in human plasma are stable after freeze–thaw (three cycles), in the autosampler (3 days), in the refrigerator (3 days) and at room temperature (clarithromycin and 14-hydroxyclarithromycin: 3 days; rifampicin and 25-desacetylrifampicin: 1 day). The developed rapid and fully validated liquid chromatography–tandem mass spectrometry (LC/MS/MS) method is suitable for the determination of clarithromycin, 14-hydroxyclarithromycin, rifampicin and 25-desacetylrifampicin in human plasma.  相似文献   

11.
Fermentation broth and biomass from three strains of Botryodiplodia theobromae were characterized by high performance liquid chromatography–electrospray tandem mass spectrometry (HPLC–ESI–MS/MS) method, in order to quantify different phytohormones and to identify amino acid conjugates of jasmonic acid (JA) present in fermentation broths. A liquid–liquid extraction with ethyl acetate was used as sample preparation. The separation was carried out on a C18 reversed-phase HPLC column followed by analysis via ESI–MS/MS. The multiple reaction monitoring mode was used for quantitative measurement. For the first time, indole-3-acetic acid, indole-3-propionic acid, indole-3-butyric acid and JA were identified and quantified in the ethyl acetate extracts from the biomass, after the separation of mycelium from supernatant. The fermentation broths showed significantly higher levels of JA in relation to the other phytohormones. This is the first report of the presence of gibberellic acid, abscisic acid, salicylic acid and the cytokinins zeatin, and zeatin riboside in fermentation broths of Botryodiplodia sp. The presence of JA-serine and JA-threonine conjugates in fermentation broth was confirmed using HPLC-ESI tandem mass spectrometry in negative ionization mode, while the occurrence of JA-glycine and JA-isoleucine conjugates was evidenced with the same technique but with positive ionization. The results demonstrated that the used HPLC–ESI–MS/MS method was effective for analysing phytohormones in fermentation samples.  相似文献   

12.
A rapid and sensitive liquid chromatography–electrospray ionization tandem mass spectrometry method (LC–ESI-MS/MS) was developed and validated for the determination of goserelin in rabbit plasma. Various parameters affecting plasma sample preparation, LC separation, and MS/MS detection were investigated, and optimized conditions were identified. Acidified plasma samples were applied to Oasis® HLB solid-phase extraction (SPE) cartridges. Extracted samples were evaporated under a stream of nitrogen and then reconstituted with 100 μL mobile phase A. The separation was achieved on a Capcell-Pak C18 (2.0 mm × 150 mm, 5 μm, AQ type) column with a gradient elution of solvent A (0.05% acetic acid in deionized water/acetonitrile = 85/15; v/v) and solvent B (acetonitrile) at a flow rate of 250 μL/min. The LC–MS/MS system was equipped with an electrospray ion source operating in positive ion mode. Multiple-reaction monitoring (MRM) of the precursor–product ion transitions consisted of m/z 635.7 → m/z 607.5 for goserelin and m/z 424.0 → m/z 292.1 for cephapirin (internal standard). The proposed method was validated by assessing specificity, linearity, limit of quantification (LOQ), intra- and inter-day precision and accuracy, recovery, and stability. Linear calibration curves were obtained in the concentration range of 0.1–20 ng/mL (the correlation coefficients were above 0.99). The LOQ of the method was 0.1 ng/mL. Results obtained from the validation study of goserelin showed good accuracy and precision at concentrations of 0.1, 1, 5, 10, and 20 ng/mL. The validated method was successfully applied to a pharmacokinetic study of goserelin after a single subcutaneous injection of 3.6 mg of goserelin in healthy white rabbits.  相似文献   

13.
A rapid, selective and highly sensitive high performance liquid chromatography–tandem mass spectrometry method (LC–MS/MS) was developed and validated for the determination and pharmacokinetic investigation of eptifibatide in human plasma. Eptifibatide and the internal standard (IS), EPM-05, were extracted from plasma samples using solid phase extraction. Chromatographic separation was performed on a C18 column at a flow rate of 0.5 mL/min. Detection of eptifibatide and the IS was achieved by tandem mass spectrometry with an electrospray ionization (ESI) interface in positive ion mode. Traditional multiple reaction monitoring (MRM) using the transition of m/z 832.6 → m/z 646.4 and m/z 931.6 → m/z 159.4 was performed to quantify eptifibatide and the IS, respectively. The calibration curves were linear over the range of 1–1000 ng/mL with the lower limit of quantitation validated at 1 ng/mL. The intra- and inter-day precisions were within 13.3%, while the accuracy was within ±7.6% of nominal values. The validated LC–MS/MS method was successfully applied for the evaluation of pharmacokinetic parameters of eptifibatide after intravenous (i.v.) administration of a 45 μg/kg bolus of eptifibatide to 8 healthy volunteers.  相似文献   

14.
Liquid chromatography–thermospray mass spectrometry (LC–TSP-MS) using isotope dilution was investigated for quantitative analysis of cortisol, cortisone, prednisolone and prednisone in human plasma. Complete separation attained by a LiChroCART Supersupher reversed-phase column and elution with 0.05 M ammonium formate–tetrahydrofuran–methanol (180:53:17, v/v/v) resulted in a significantly large isotope effect of the deuterium-labeled analogs on the HPLC behavior and caused difficulty in quantification. Reduction of the isotope effect on the retention times using 0.05 M ammonium formate–acetonitrile (65:35, v/v) permitted accurate quantification of cortisol and cortisone by the isotope dilution LC–TSP-MS, although separation between cortisol and prednisone was incomplete.  相似文献   

15.
A rapid, highly sensitive method for the determination of morphine and its metabolites morphine-3-glucuronide (M3G), morphine-6-glucuronide (M6G) and normorphine has been developed using high-performance liquid chromatography–electrospray mass spectrometry, with the deuterated analogues as internal standards. The analytes were extracted automatically using end-capped C2 solid-phase extraction cartridges. Baseline separation of morphine, M3G and M6G was achieved on a LiChrospher 100 RP-18 end-capped analytical column (125×3 mm I.D., 5 μm particle size) with water–acetonitrile–tetrahydrofuran–formic acid (100:1:1:0.1, v/v) as the mobile phase. Morphine and normorphine coeluate and were separated mass spectrometrically. The mass spectrometer was operated in the selected-ion monitoring mode using m/z 272 for normorphine, m/z 286 for morphine, m/z 462 for morphine-6-glucuronide. Due to an interfering peak, M3G was measured by tandem mass spectrometry in the daughter-ion mode. The limits of quantitation achieved with this method were 1.3 pmol/ml for morphine, 1.5 pmol/ml for normorphine, 1.0 pmol/ml for M6G and 5.4 pmol/ml for M3G in serum or cerebrospinal fluid. The limits of quantitation achieved in urine were 10 pmol/ml for morphine, 20 pmol/ml for normorphine and M6G and 50 pmol/ml for M3G using a sample size of 100 μl. The method described was successfully applied to the determination of morphine and its metabolites in human serum, cerebrospinal fluid and urine in pharmacokinetic and drug interaction studies.  相似文献   

16.
A kinetic study of atosiban was conducted following repeated intravenous administration in Wistar rats. Sample analysis was performed using liquid chromatography–tandem mass spectrometry (LC–MS/MS) following full validation of an in-house method. Eptifibatide, a cyclic peptide, was used as an internal standard (IS). The analyte and internal standard were extracted using solid phase extraction (SPE) method. Chromatographic separation was carried out using an ACE C18 5 μm 50 mm × 4.6 mm column with gradient elution. Mass spectrometric detection was performed using TSQ Quantum ultra AM. The lower limit of quantification was 0.01 μg/ml when 100 μl rat plasma was used. Plasma concentrations of atosiban were measured at 0 (pre-dose), 2, 15, 30, 45, 60, 120 min at the dosage levels of 0.125 mg/kg (low dose), 0.250 mg/kg (mid dose), and 0.500 mg/kg (high dose), respectively. Atosiban plasma concentration measured at Day 1 showed mean peak atosiban concentration (Cmax) 0.40, 0.57, 1.95 μg/ml for low, mid and high dose treated animals and mean peak concentration on Day 28 was 0.41, 0.88, 1.31 μg/ml on Day 28 for low, mid and high dose treated animals.  相似文献   

17.
A rapid, specific and sensitive liquid chromatography–electrospray ionization-tandem mass spectrometry method was developed and validated for determination of cymipristone in human plasma. Mifepristone was used as the internal standard (IS). Plasma samples were deproteinized using methanol. The compounds were separated on a ZORBAX SB C18 column (50 mm × 2.1 mm i.d., dp 1.8 μm) with gradient elution at a flow-rate of 0.3 ml/min. The mobile phase consisted of 10 mM ammonium acetate and acetonitrile. The detection was performed on a triple-quadruple tandem mass spectrometer by selective reaction monitoring (SRM) mode via electrospray ionization. Target ions were monitored at [M+H]+ m/z 498  416 and 430  372 in positive electrospray ionization (ESI) mode for cymipristone and IS, respectively. Linearity was established for the range of concentrations 0.5–100 ng/ml with a coefficient correlation (r) of 0.9996. The lower limit of quantification (LLOQ) was identifiable and reproducible at 0.5 ng/ml. The validated method was successfully applied to study the pharmacokinetics of cymipristone in healthy Chinese female subjects.  相似文献   

18.
A sensitive and specific method for determination of the residues of 50 anabolic hormones in muscle (pork, beef, shrimp), milk and pig liver was developed. Analytes were separated and acquired by liquid chromatography coupled with an electrospray ionization tandem mass spectrometer (LC–ESI–MS/MS). Target compounds were simultaneously extracted with methanol after enzyme hydrolysis, and purified using a graphitized carbon-black solid-phase extraction (SPE) and followed by NH2 SPE cartridge. Limits of quantification were 0.04–2.0 μg kg?1; average recoveries were 76.9–121.3%; and the relative standard deviation was 2.4–21.2%. This method has been successfully applied in real samples.  相似文献   

19.
Perchlorate can competitively inhibit iodide uptake by the thyroid gland (TG) via the sodium/iodide symporter, consequently reducing the production of thyroid hormones (THs). Until recently, the effects of perchlorate on TH homeostasis are being examined through measurement of serum levels of TH, by immunoassay (IA)-based methods. IA methods are fast, but for TH analysis, they are compromised by the lack of adequate specificity. Therefore, selective and sensitive methods for the analysis of THs in TG are needed, for assessment of the effects of perchlorate on TH homeostasis. In this study, we developed a method for the analysis of six THs: l-thyroxine (T4), 3,3′,5-triiodo-l-thyronine (T3), 3,3′,5′-triiodo-l-thyronine (rT3), 3,5-diiodo-l-thyronine (3,5-T2), 3,3′-diiodo-l-thyronine (3,3′-T2), and 3-iodo-l-thyronine (3-T1) in TG, using liquid chromatography (LC)–tandem mass spectrometry (MS/MS). TGs used in this study were from rats that had been placed on either iodide-deficient diet or iodide-sufficient diet, and that had either been provided with perchlorate in drinking water (10 mg/kg/day) or control water. TGs were extracted by pronase digestion and then analyzed by LC–MS/MS. The instrumental calibration range for each TH ranged from 1 to 200 ng/ml and showed a high linearity (r > 0.99). The method quantification limits (LOQs) were determined to be 0.25 ng/mg TG for 3-T1; 0.33 ng/mg TG for 3,3′- and 3,5-T2; and 0.52 ng/mg TG for rT3, T3, and T4. Rats were placed on an iodide-deficient or -sufficient diet for 2.5 months, and for the last 2 weeks of that period were provided either perchlorate (10 mg/kg/day) in drinking water or control water. Iodide deficiency and perchlorate administration both reduced TG stores of rT3, T3, and T4. In iodide-deficient rats, perchlorate exacerbated the reduction in levels of THs in TG. With the advances in analytical methodology, the use of LC–MS/MS for measurement of hormone levels in TG will allow more comprehensive evaluations of the hypothalamic-pituitary–thyroid axis.  相似文献   

20.
A rapid and selective high performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS) method for simultaneous determination of isoniazid (INH), rifampicin (RFP) and levofloxacin (LVX) in mouse tissues and plasma has been developed and validated, using gatifloxacin as the internal standard (I.S.). The compounds and I.S. were extracted from tissue homogenate and plasma by a protein precipitation procedure with methanol. The HPLC separation of the analytes was performed on a Welch materials C4 column (250 mm × 4.6 mm, 5.0 μm, USA) at 25 °C, using a gradient elution program with the initial mobile phase constituting of 0.05% formic acid and methanol (93:7, v/v) at a flow-rate of 1.0 ml/min. For all the three analytes, the recoveries varied between 83.3% and 98.8% in tissues and between 75.5% and 90.8% in plasma, the accuracies ranged from 91.7% to 112.0% in tissues and from 94.6% to 108.8% in plasma, and the intra- and inter-day precisions were less than 13.3% in tissues and less than 8.2% in plsama. Calibration ranges for INH were 0.11–5.42 μg/g in tissues and 0.18–9.04 μg/ml in plasma, for RFP were 0.12–1200 μg/g in tissues and 4.0–200 μg/ml in plasma, and for LVX were 0.13–26.2 μg/g in tissues and 0.09–4.53 μg/ml in plasma. The lower limits of quantification (LLOQs) for INH, RFP and LVX in mouse tissues were 0.11, 0.12 and 0.13 μg/g and for those in mouse plasma were 18.1, 20.0 and 21.8 ng/ml, respectively. The limits of detection (LODs) for INH, RFP and LVX in mouse tissues were 0.04, 0.05 and 0.05 μg/g and for those in mouse plasma were 5.5, 6.0 and 6.6 ng/ml, respectively. The established method was successfully applied to simultaneous determination of isoniazid, rifampicin and levofloxacin in mouse plasma and different mouse tissues.  相似文献   