首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Most deaths from ischaemic heart disease are sudden, occur outside hospital, and result from ventricular fibrillation. But defibrillators have only limited availability because of their size and weight. A miniature defibrillator has been developed. A singe low-energy shock succeeded in removing ventricular fibrillation in 73 out of 82 episodes, and a further shock was successful in seven more episodes. Primary ventricular fibrillation probably always responds to low-energy electrical shocks, which challenges the conventional view that correction of ventricular fibrillation requires high-energy direct-current shock. Thus even smaller and lighter defibrillators are possible. Furthermore low-energy shocks cause less myocardial damage.  相似文献   

2.
Early ventricular fibrillation occurs in approximately 5% of patients admitted for acute myocardial infarction. Although late ventricular fibrillation (> 48 hours postinfarction) may occur in stable patients, it occurs more commonly when severe left ventricular power failure is present. We have encountered late ventricular fibrillation in three of 42 (7%) patients treated with intraaortic balloon pumping (IABP) for profound cardiogenic shock secondary to myocardial infarction. These patients progressed to our hemodynamic Class A prior to weaning, and were thought to be stable prior to IABP removal. They were the only ones who expired after achieving Class A status. The episodes of late ventricular fibrillation occurred after the patients had been successfully weaned from IABP and were free of arrhythmias. This experience suggests that prolonged antiarrhythmic therapy may be indicated for postinfarction patients who have had ventricular dysrhythmias during IABP support.  相似文献   

3.
Barley, Hordeum vulgare L., one of the important crops in Canada, is used in malting, feed, and food industries. Disinfestation of barley using microwaves can be an alternative to chemical methods used to kill insects. A pilot-scale industrial microwave system operating at 2.45 MHz was used in this study to determine the mortality of life stages (egg, larva, pupa, and adult) of Tribolium castaneum (Herbst) (Coleoptera: Tenebrionidae). Barley samples of 50 g each at 14, 16, and 18% moisture content (MC; wet basis) were infested with various life stages of T. castaneum and exposed to microwave energy at different power levels and exposure times, and the mortality of the insects was determined. The average temperature of the 14% MC sample exposed to 28 s at 0, 200, 300, 400, and 500 W were 27.4, 42.6, 53.7, 66.9, and 73.0 degrees C, respectively, and those exposed to 56 s at 0, 200, 300, and 400 W were 27.4, 57.3, 75.5, and 91.2 degrees C, respectively. A similar range of temperature was observed for 16 and 18% MC barley. Complete mortality of all life stages of T. castaneum can be achieved at a power level of 400 W and an exposure time of 56 s or at 500 W for 28 s. Among the life stages of T. castaneum, eggs were the most susceptible to microwave energy and adults were the least susceptible. There was no significant difference in the mortality of larvae and adults at 14, 16, and 18% MC, but the mortality was significantly different for eggs and pupae at different MCs. There was a significant increase in the mortality with an increase in power level or exposure time or both. Germination capacity of the seeds was decreased with an increase in power level or exposure time or both. Quality characteristics such as alpha-amylase, diastatic power, soluble protein, viscosity, and density of the barley malt treated at 500 W for 28 s were same as the control sample, whereas the samples treated at 400 W for 56 s were significantly lower.  相似文献   

4.
Of 160 patients who survived ventricular fibrillation complicating acute ischaemic heart disease, 80 had had a clinically mild coronary attack. Most of the long-term survivors had ventricular fibrillation within 24 hours of the onset of symptoms. The longterm prognosis of the survivors was similar to that of patients whose myocardial infarction was not complicated by ventricular fibrillation. Those patients who survived ventricular fibrillation which occurred within four hours of the onset of symptoms were younger, usually had had a mild coronary attack, and had the most favourable longterm prognosis. The number of episodes of ventricular fibrillation did not affect adversely the long-term prognosis. Of those who at the time of review were eligible to work, 86% were fit to work and 68% were actually at work.  相似文献   

5.
Short-coupled idiopathic ventricular fibrillation (IVF) is a subtype of IVF in which episodes of polymorphic ventricular tachycardia or ventricular fibrillation are initiated by short-coupled premature ventricular contractions (PVCs). Our understanding of the pathophysiology is evolving, with evidence suggesting that these malignant PVCs originate from the Purkinje system. In most cases, the genetic underpinning has not been identified. Whereas the implantation of an implantable cardioverter-defibrillator is uncontroversial, the choice of pharmacological treatment is the subject of discussion. In this review, we summarize the available knowledge on pharmacological therapy in short-coupled IVF and provide our recommendations for management of patients with this syndrome.  相似文献   

6.
Implantable defibrillators are lifesavers and have improved mortality rates in patients at risk of sudden death, both in primary and secondary prevention. However, they are unable to modify the myocardial substrate, which remains susceptible to life-threatening ventricular arrhythmias. Electrical storm is a clinical entity characterized the recurrence of hemodynamically unstable ventricular tachycardia and/or ventricular fibrillation, twice or more in 24 hours, requiring electrical cardioversion or defibrillation. With the arrival of the implantable cardioverter-defibrillator, this definition was broadened, and electrical storm is now defined as the occurrence of three or more distinct episodes of ventricular tachycardia or ventricular fibrillation in 24 hours, requiring the intervention of the defibrillator (anti-tachycardia pacing or shock). Clinical presentation can be very dramatic, with multiple defibrillator shocks and hemodynamic instability. Managing its acute presentation is a challenge, and mortality is high both in the acute phase and in the long term. In large clinical trials involving patients implanted with a defibrillator both for primary and secondary prevention, electrical storm appears to be a harbinger of cardiac death, with notably high mortality soon after the event. In most cases, the storm can be interrupted by medical therapy, though transcatheter radiofrequency ablation of ventricular arrhythmias may be an effective treatment for refractory cases.This narrative literature review outlines the main clinical characteristics of electrical storm and emphasises critical points in approaching and managing this peculiar clinical entity. Finally focus is given to studies that consider transcatheter ablation therapy in cases refractory to medical treatment.  相似文献   

7.

Background

Implantable cardioverter defibrillators (ICDs) are designed to deliver shocks or antitachycardia pacing (ATP) in the event of ventricular arrhythmias. During follow-up, some ICD recipients experience the sensation of ICD discharge in the absence of an actual discharge (phantom shock). The aim of this study was to evaluate the incidence and predictors of phantom shocks in ICD recipients.

Methods

Medical records of 629 consecutive patients with ischaemic or dilated cardiomyopathy and prior ICD implantation were studied.

Results

With a median follow-up of 35 months, phantom shocks were reported by 5.1 % of ICD recipients (5.7 % in the primary prevention group and 3.7 % for the secondary prevention group; p=NS). In the combined group of primary and secondary prevention, there were no significant predictors of the occurrence of phantom shocks. However, in the primary prevention group, phantom shocks were related to a history of atrial fibrillation (p=0.03) and NYHA class <III (p=0.05). In the secondary prevention group, there were no significant predictors for phantom shocks.

Conclusion

Phantom shocks occur in approximately 5 % of all ICD recipients. In primary prevention patients, a relation with a history of atrial fibrillation and NYHA class <III were significant predictors for the occurrence of phantom shocks. In the secondary prevention patients, no significant predictors were found.  相似文献   

8.
Sustained ventricular tachycardia (VT) is an important cause of morbidity and sudden death in patients with dilated cardiomyopathy. Although ICD effectively terminate VT episodes and improve survival, shocks reduce quality of life, and episodes of VT predict increased risk of heart failure and death despite effective therapy. Patients suffering recurrent VT episodes remain a challenge. Antiarrhytmic therapy reduces VT episodes, but it is associated with serious adverse events, and disappointing efficacy. Catheter ablation has emerged as an important option to control recurrent VT, but major procedure-related complications, and even death, are still issues to concern. And even with these armamentaria, some patients still have recurrent VT episodes and ICD shocks. We report on a patient with non-ischemic dilated cardiomyopathy and recurrent ventricular tachycardia resistant to multiple antiarrhytmic agents, in whom dronedarone was effective in completely suppressing ventricular tachycardia episodes.  相似文献   

9.
The overall results over three and a half years of the treatment of ventricular fibrillation secondary to ischaemic heart disease in the Royal Sussex County Hospital were reviewed. Records of all patients who were brought to hospital by resuscitation ambulances or who were admitted to the coronary care unit from any source were analysed. Eighty-seven of the 174 patients (50%) who developed ventricular fibrillation were discharged. The survivors included 13 out of 61 patients (21%) in whom fibrillation was secondary to cardiogenic shock or severe left ventricular failure. The presence of resuscitation equipment and nursing staff trained to use it in the general wards and emergency areas ensured a uniformly high success rate throughout the hospital, similar to that achieved in the coronary care unit. Prompt defibrillation in the general wards and the accident and emergency department may improve overall survival.  相似文献   

10.
The probabilistic nature of the ventricular defibrillation threshold (DFT) remains poorly understood. We hypothesized that shock outcome is a function of the amount of myocardium in its vulnerable period (VP). The endocardial surface of five isolated, perfused swine right ventricles was mapped with 477 bipolar electrodes during ventricular fibrillation (VF). Shock parameters and VF cycle length were not significantly different in the successful (S; n = 26) and failed (F; n = 26) trials. At the instant of the shock, the number of sites with 45- to 55-ms recovery was significantly smaller in the S trials than the F trials (P < 0.04). No significant difference in the number of sites with recovery intervals outside the 45- to 55-ms range was seen in S and F shocks. Endocardial action potential showed that a recovery time of 45-55 ms corresponded to the VP spanning -15 to -60 mV in 92% of the regenerative action potentials. We conclude that the probabilistic nature of the DFT is related to the amount of myocardium in its VP.  相似文献   

11.
Energy requirements for successful antiarrhythmia shocks are arrhythmia specific. However, it remains unclear why the probability of shock success decreases with increasing arrhythmia complexity. The goal of this research was to determine whether a diminished probability of shock success results from an increased number of functional reentrant circuits in the myocardium, and if so, to identify the responsible mechanisms. To achieve this goal, we assessed shock efficacy in a bidomain defibrillation model of a 4-mm-thick slice of canine ventricles. Shocks were applied between a right ventricular cathode and a distant anode to terminate either a single scroll wave (SSW) or multiple scroll waves (MSWs). From the 160 simulations conducted, dose-response curves were constructed for shocks given to SSWs and MSWs. The shock strength that yielded a 50% probability of success (ED(50)) for SSWs was found to be 13% less than that for MSWs, which indicates that a larger number of functional reentries results in an increased defibrillation threshold. The results also demonstrate that an isoelectric window exists after both failed and successful shocks; however, shocks of strength near the ED(50) value that were given to SSWs resulted in 16.3% longer isoelectric window durations than the same shocks delivered to MSWs. Mechanistic inquiry into these findings reveals that the two main factors underlying the observed relationships are 1) smaller virtual electrode polarizations in the tissue depth, and 2) differences in preshock tissue state. As a result of these factors, intramural excitable pathways leading to delayed breakthrough on the surface were formed earlier after shocks given to MSWs compared with SSWs and thus resulted in a lower defibrillation threshold for shocks given to SSWs.  相似文献   

12.
Defibrillation testing is no longer routinely performed after automatic implantable cardioverter-defibrillator (AICD) implantation. However, certain subjects undergoing AICD implantation may be at higher risk of undersensing of ventricular arrhythmias resulting in potentially fatal outcomes. We present the case of a 30-year-old woman with hypertrophic cardiomyopathy (HCM; ‘asymmetric septal hypertophy’ morphologic variant) and prophylactic AICD who experienced an out of hospital cardiac arrest. AICD interrogation revealed undersensing as a result of intermittent high amplitude electrograms during an episode of ventricular fibrillation (VF). The subject underwent replacement and repositioning of the AICD lead along with pulse generator replacement (that utilized a different VF sensing algorithm) with appropriate sensing of VF and successful defibrillation testing. The presence of intermittent high amplitude electrograms during episodes of VF in AICDs using the AGC function should be recognized as a situation that may necessitate interventions to prevent undersensing and consequent delay in therapy.  相似文献   

13.
A previous two-dimensional (2D) ultrasound study suggested that there is relaxation of the myocardium after defibrillation. The 2D study could not measure activity occurring within the first 33 ms after the shock, a period that may be critical for discriminating between shock- and excitation-induced relaxation. The objective of our study was to determine the left ventricular (LV) geometry during the first 33 ms after defibrillation. Biphasic defibrillation shocks were delivered 5-50 s after the induction of ventricular fibrillation in each of the seven dogs. One-dimensional, short-axis ultrasound images of the LV cavity were acquired at a rate of 250 samples/s. The LV cavity diameter was computed from 32 ms before to 32 ms after the shock. Preshock and postshock percent changes in LV diameter were analyzed as a function of time with the use of regression analysis. The normalized mean pre- and postshock slopes (0.2 +/- 2.2 and 3.3 +/- 7.9% per 10 ms) were significantly different (P < 0.01). The postshock slope was positive (P < 0.005). Our results confirm that the bulk of the myocardium is relaxing immediately after defibrillation.  相似文献   

14.
摘要 目的:探讨右室Tei指数、血清醛固酮水平对慢性阻塞性肺病(COPD)患者发生房颤的预测价值。方法:根据房颤的发生情况,将200例COPD患者分为房颤发生组和无房颤发生组。比较两组的病程、COPD严重程度、血清醛固酮(ALD)水平及右室Tei指数、肺动脉压、右心室横径的差异,分析右室Tei指数和ALD预测房颤发生的ROC曲线下面积、截断值、灵敏度及特异度。结果:房颤发生组病程(8.48±1.3和7.59±1.75)、右心室横径(40.52±2.74和36.27±2.4)、血清ALD(137.64±42.77和98.61±15.39)、右室Tei指数(0.37±0.12和0.31±0.07)、COPD、肺动脉高压的严重程度与无房颤发生组比较差异都有统计学意义(P<0.05)。logistic回归分析结果显示ALD、右室Tei指数、病程、和肺动脉高压程度为影响COPD患者发生房颤的独立影响因素。右室Tei指数预测房颤发生的ROC曲线下面积AUC=0.645,截断值为0.420,灵敏度为38.0%,特异度达到93.33%;ALD预测房颤发生的ROC曲线下面积为0.792,截断值为122.72 pg/mL,灵敏度为66.0%,特异度可达到98.0%。结论:右室Tei指数和血清醛固酮水平可作为慢性阻塞性肺病患者发生房颤的预测参考指标。  相似文献   

15.
Accurately differentiating between ventricular fibrillation (VF) and ventricular tachycardia (VT) episodes is crucial in preventing potentially fatal misinterpretations. If VT is misinterpreted as VF, the patient will receive an unnecessary shock that could damage the heart; conversely, if VF is incorrectly interpreted as VT, the result will be life-threatening. In this study, a new method called semantic mining is used to characterize VT and VF episodes by extracting their significant characteristics (the frequency, damping coefficient and input signal). This newly proposed method was tested using a widely recognized database provided by the Massachusetts Institute of Technology (MIT) and achieved high detection accuracy of 96.7%. The semantic mining technique was capable of completely discriminating between normal rhythms and VT and VF episodes without any false detections and also distinguished VT and VF episodes from one another with a recognition sensitivity of 94.1% and 95.2% for VT and VF, respectively.  相似文献   

16.
The technique of selective coronary arteriography, as described originally by Sones, was employed in 255 patients. Successful catheterization of both coronary arteries was carried out in 88% of these patients, and in the last 100 examinations both coronary arteries were entered in 95 patients. Selective coronary arteriography is a useful diagnostic tool but is a potentially hazardous form of examination as we encountered four episodes of ventricular fibrillation in the present series.  相似文献   

17.
Early investigators suggested that ventricular fibrillation without heart failure in acute myocardial infarction was reliably preceded by warning arrhythmias, and that suppression of such arrhythmias with intravenous lidocaine could avoid the need for resuscitation. While the efficacy and safety of lidocaine have been substantiated, the reliability of warning arrhythmias as predictors for primary ventricular fibrillation has not. We present data showing that the risk of primary ventricular fibrillation is most dependent on the patient''s age and the interval since the onset of his symptoms, rather than on the presence of warning arrhythmias. We have estimated that lidocaine prophylaxis would have to be given to about 12 patients in the highest risk group (patients under age 50 and within six hours of the onset of symptoms), compared to about 400 patients in the lowest risk group (patients above age 70 and more than 24 hours since the onset of symptoms), to prevent one episode of primary ventricular fibrillation in each group. We propose that these risk stratifications, as adapted to the conditions in specific hospitals, provide the most rational approach to lidocaine prophylaxis of primary ventricular fibrillation.  相似文献   

18.
During ventricular fibrillation (VF) only 39% of the variation in action potential duration (APD) is accounted for by the previous diastolic interval [DI((n-1))], i.e., restitution, and the previous APD [APD((n-1))], i.e., memory. We tested the hypothesis that a characteristic of the AP upstroke, the maximum rate of depolarization (V(max)), also helps account for its APD. A floating microelectrode was used to make transmembrane recordings at 16,000 samples/s from the anterior left ventricular wall during four 20-s episodes of VF in each of six pigs. V(max), time from V(max) to 60% repolarization (APD(60)), and DI were calculated throughout all episodes. Stepwise linear regression was used to determine how well each APD(60) (APD(60n)) was predicted by V(max) of that AP, the four previous DIs (n-1, n - 2, n - 3, n - 4), and the three previous APD(60)s (n-1, n - 2, n - 3). V(max) entered in the regression equation significantly more often (86% of VF episodes) than either APD((n-1)) (47% of episodes) or DI((n-1)) (58% of episodes). When these three variables entered first or second, their coefficients were almost always positive, consistent with a longer APD associated with 1) a larger V(max), 2) a longer APD((n-1)), and 3) a longer DI((n-1)). R(2) of the regression for all entered variables was 0.51 +/- 0.01 (mean +/- SD). During the first 20 s of VF in swine, V(max) is a more important determinant of APD than the previous DI (restitution) or the previous APD (memory). All variables together account for only one-half of APD variation during VF.  相似文献   

19.

Objective

Quantitative ventricular fibrillation (VF) waveform analysis is a potentially powerful tool to optimize defibrillation. However, whether combining VF features with additional attributes that related to the previous shock could enhance the prediction performance for subsequent shocks is still uncertain.

Methods

A total of 528 defibrillation shocks from 199 patients experienced out-of-hospital cardiac arrest were analyzed in this study. VF waveform was quantified using amplitude spectrum area (AMSA) from defibrillator''s ECG recordings prior to each shock. Combinations of AMSA with previous shock index (PSI) or/and change of AMSA (ΔAMSA) between successive shocks were exercised through a training dataset including 255shocks from 99patientswith neural networks. Performance of the combination methods were compared with AMSA based single feature prediction by area under receiver operating characteristic curve(AUC), sensitivity, positive predictive value (PPV), negative predictive value (NPV) and prediction accuracy (PA) through a validation dataset that was consisted of 273 shocks from 100patients.

Results

A total of61 (61.0%) patients required subsequent shocks (N = 173) in the validation dataset. Combining AMSA with PSI and ΔAMSA obtained highest AUC (0.904 vs. 0.819, p<0.001) among different combination approaches for subsequent shocks. Sensitivity (76.5% vs. 35.3%, p<0.001), NPV (90.2% vs. 76.9%, p = 0.007) and PA (86.1% vs. 74.0%, p = 0.005)were greatly improved compared with AMSA based single feature prediction with a threshold of 90% specificity.

Conclusion

In this retrospective study, combining AMSA with previous shock information using neural networks greatly improves prediction performance of defibrillation outcome for subsequent shocks.  相似文献   

20.
R. W. Dhurandhar  S. J. Teasdale  W. A. Mahon 《CMAJ》1971,105(2):161-165,173
Nine patients who had recurrent ventricular fibrillation following acute myocardial infarction or angina were given bretylium tosylate in a dose of 5 mg./kg. intramuscularly every eight hours after other measures had proved ineffective. Provided the patients were not in shock or in heart failure, there was a considerable reduction in the episodes of ventricular fibrillation.A second group of nine patients who developed recurrent ventricular fibrillation following open heart surgery were given bretylium intravenously, which controlled the arrhythmia in every instance.Bretylium did not completely abolish ventricular premature beats but the latter did not initiate ventricular fibrillation even when they occurred on the T wave.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号