共查询到20条相似文献,搜索用时 15 毫秒
1.
Zhao YY Cheng XL Liu R Ho CC Wei F Yan SH Lin RC Zhang Y Sun WJ 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(21):1945-1953
Rapid resolution liquid chromatography/tandem multi-stage mass spectrometry (RRLC-MS(n)) and rapid resolution liquid chromatography/tandem mass spectrometry (RRLC/MS/MS) methods were developed for the identification and quantification of ergosterol and its metabolites from rat plasma, urine and faeces. Two metabolites (ERG1 and ERG2) were identified by RRLC/MS(n). The concentrations of the ergosterol were determined by RRLC/MS/MS. The separation was performed on an Agilent Zorbax SB-C18 with the mobile phase consisting of methanol and water (containing 0.1% formic acid). The detection was carried out by means of atmospheric pressure chemical ionization mass spectrometry in positive ion mode with multiple reaction monitoring (MRM). Linear calibration curves were obtained in the concentration range of 7-2000, 6-2000 and 8-7500 ng/mL for plasma, urine and faecal homogenate, respectively. The intra- and inter-day precision values (RSD) were below 10%. The method was applied to the pharmacokinetic properties and elimination pathway of ergosterol in rats. 相似文献
2.
Gu Y Wang G Fawcett JP 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2004,801(2):285-288
Astragaloside IV (AGS-IV) is an active constituent of Radix Astragali used in many Traditional Chinese Medicines. This paper describes a sensitive and specific assay for the quantitation of AGS-IV in rat plasma. After solid phase extraction (SPE), samples were analyzed by liquid chromatography electrospray ionization mass spectrometry using a reversed-phase C18 column. The assay was linear in the range 1-500 ng/ml with a limit of detection of 0.5 ng/ml. The recovery was 92.5% and within-day and between-day precision were 3.7-6.0 and 2.8-9.8%, respectively. The assay was applied to a pharmacokinetic study in rat after a single oral dose. The drug was rapidly absorbed and subsequently eliminated according to a biphasic concentration-time curve. 相似文献
3.
Feng S Hu P Jiang J 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(11-12):763-768
Higenamine is an active ingredient of Aconite root in Chinese herbal medicine and might be used as a new agent for a pharmaceutical stress test and was approved to undergo clinical pharmacokinetic study. Therefore, there exists a need to establish a sensitive and rapid method for the determination of higenamine in human plasma and urine. This paper described a sensitive and rapid method based on liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) for the determination of higenamine in human plasma and urine. Solid-phase extraction (SPE) was used to isolate the compounds from biological matrices followed by injection of the extracts onto an Atlantis dC18 column with isocratic elution. The mobile phase was 0.05% formic acid in water-methanol (40:60, v/v). The mass spectrometry was carried out using positive electrospray ionization (ESI) and data acquisition was carried out in the multiple reaction monitoring (MRM) mode. The method was fully validated over the concentration range of 0.100-50.0 ng/mL and 1.00-500 ng/mL in plasma and urine, respectively. The lower limits of quantification (LLOQs) were 0.100 and 1.00 ng/mL in plasma and urine, respectively. Inter- and intra-batch precision was less than 15% and the accuracy was within 85-115% for both plasma and urine. Extraction recovery was 82.1% and 56.6% in plasma and urine, respectively. Selectivity, matrix effects and stability were also validated in human plasma and urine. The method was applied to the pharmacokinetic study of higenamine hydrochloride in Chinese healthy subjects. 相似文献
4.
Determination of tamsulosin in dog plasma by liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry 总被引:2,自引:0,他引:2
Qi M Wang P Liu L 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2004,805(1):7-11
A rapid, sensitive and accurate liquid chromatographic-tandem mass spectrometric method is described for the determination of tamsulosin in dog plasma. Tamsulosin was extracted from plasma using a mixture of hexane-ethyl acetate (2:1, v/v) and separated on a C18 column interfaced with a triple quadrupole tandem mass spectrometer. The mobile phase consisting of a mixture of methanol, water and formic acid (80:20:1, v/v/v) was delivered at a flow rate of 0.5 ml/min. Atmospheric pressure chemical ionization (APCI) source was operated in positive ion mode. Selected reaction monitoring (SRM) mode using the transitions of m/z 409-->m/z 228 and m/z 256-->m/z 166.9 were used to quantify tamsulosin and the internal standard, respectively. The linearity was obtained over the concentration range of 0.1-50.0 ng/ml for tamsulosin and the lower limit of quantitation was 0.1 ng/ml. For each level of QC samples, inter- and intra-run precision was less than 5.0 and 4.0% (relative standard deviation (R.S.D.)), respectively, and accuracy was within +/-0.3% (relative error (R.E.)). This method was successfully applied to pharmacokinetic study of a tamsulosin formulation product after oral administration to beagle dogs. 相似文献
5.
Determination of glimepiride in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry 总被引:2,自引:0,他引:2
Salem II Idrees J Al Tamimi JI 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2004,799(1):103-109
A sensitive and specific high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS-MS) method has been developed at our center for the determination of glimepiride in human plasma. After the addition of the internal standard, plasma samples were extracted by liquid-liquid extraction technique using diethyl ether. The compounds were separated on a prepacked C18 column using a mixture of acetonitrile, methanol and ammonium acetate buffer as mobile phase. A Finnigan LCQDUO ion trap mass spectrometer connected to an Alliance Waters HPLC was used to develop and validate the method. The analytical method was validated according to the FDA bioanalytical method validation guidance. The results were within the accepted criteria as stated in the aforementioned guidance. The method was proved to be sensitive and specific by testing six different plasma batches. Linearity was established for the range of concentrations 5.0-500.0 ng/ml with a coefficient of determination (r2) of 0.9998. Accuracy for glimepiride ranged from 100.58 to 104.48% at low, mid and high levels. The intra-day precision was better than 12.24%. The lower limit of quantitation (LLOQ) was identifiable and reproducible at 5.0 ng/ml with a precision of 7.96%. The proposed method enables the unambiguous identification and quantitation of glimepiride for pharmacokinetic, bioavailability or bioequivalence studies. 相似文献
6.
Liu A Liu F Xu Y Xu F Hu W Guo Q 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2008,867(1):144-148
A simple and sensitive HPLC/MS/MS method was developed and evaluated to determine the concentration of ritodrine (RTD) in human plasma. Liquid-liquid extraction with ethyl acetate was employed as the sample preparation method. The structural analogue salbutamol was selected as the internal standard (IS). The liquid chromatography was performed on a Hanbon Sci. & Tech. Lichrospher CN (150 mm x 4.6 mm, i.d., 5 microm) column (Hanbon, China) at 20 degrees C. A mixture of 0.03% acetic acid and methanol (50:50, v/v) was used as isocratic mobile phase to give the retention time 3.60 min for ritodrine and 2.94 min for salbutamol. Selected reaction monitoring (SRM) in positive ionization mode was employed for mass detection. The calibration functions were linear over the concentration range 0.39-100 ng mL(-1). The intra- and inter-day precision of the method were less than 15%. The lower limit of quantification was 0.39 ng mL(-1). The method had been found to be suitable for application to a pharmacokinetic study after oral administration of 20mg ritodrine hydrochloride tablet to 18 healthy female volunteers. The half-life is 2.54+/-0.67 h. 相似文献
7.
Lutz Brutigam Gregor Vetter Irmgard Tegeder Georg Heinkele Gerd Geisslinger 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2001,761(2)
Methods for the determination of celecoxib in human plasma and rat microdialysis samples using liquid chromatography tandem mass spectrometry are described. Celecoxib and an internal standard were extracted from plasma by solid-phase extraction with C18 cartridges. Thereafter compounds were separated on a short narrow bore RP C18 column (30×2 mm). Microdialysis samples did not require extraction and were injected directly using a narrow bore RP C18 column (70×2 mm). The detection was by a PE Sciex API 3000 mass spectrometer equipped with a turbo ion spray interface. The compounds were detected in the negative ion mode using the mass transitions m/z 380→316 and m/z 366→302 for celecoxib and internal standard, respectively. The assay was validated for human plasma over a concentration range of 0.25–250 ng/ml using 0.2 ml of sample. The assay for microdialysis samples (50 μl) was validated over a concentration range of 0.5–20 ng/ml. The method was utilised to determine pharmacokinetics of celecoxib in human plasma and in rat spinal cord perfusate. 相似文献
8.
Geraldine Dowling Pasquale Gallo Liam Regan 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2009,877(5-6):541-546
A rapid method has been developed to analyse for firocoxib (FIRO) residue in bovine milk. Milk samples were extracted with acetonitrile and sample extracts were purified on Evolute? ABN solid phase extraction cartridges. Aliquots were analysed by rapid resolution liquid chromatography tandem mass spectrometry (RRLC–MS/MS). The method was validated in bovine milk, according to the criteria defined in Commission Decision 2002/657/EC. The decision limit (CCα) was 1.18 ng/mL and for the detection capability a (CCβ) value of 2.02 ng/mL was obtained. The measurement uncertainty of the method was 27%. Fortifying bovine milk samples (n = 18) in three separate assays, show the accuracy of the method to be between 96 and 105%. The precision of the method, expressed as RSD values for the within-lab reproducibility at the three levels of fortification (5, 7.5 and 10 ng/mL) was less than 11% respectively. 相似文献
9.
Zhu YR Jia YY Jiang L Wang C Ding LK Yang J Li L Zhao PX Liu WX Yi-Ding Wang L Wen AD 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(23):2189-2193
A sensitive method using liquid chromatography with tandem mass spectrometric detection (LC-MS/MS) was developed and validated for the analysis of antihistamine drug azatadine in human plasma. Loratadine was used as internal standard (IS). Analytes were extracted from human plasma by liquid/liquid extraction using ethyl acetate. The organic phase was reduced to dryness under a stream of nitrogen at 30 °C and the residue was reconstituted with the mobile phase. 5 μL of the resulting solution was injected onto the LC-MS/MS system. A 4.6 mm × 150 mm, I.D. 5 μm, Agilent TC-C(18) column was used to perform the chromatographic analysis. The mobile phase consisted of ammonium formate buffer 0.010 M (adjusted to pH 4.3 with 1M formic acid)/acetonitrile (20:80, v/v) The chromatographic run time was 5 min per injection and flow rate was 0.6 mL/min. The retention time was 2.4 and 4.4 min for azatadine and IS, respectively. The tandem mass spectrometric detection mode was achieved with electrospray ionization (ESI) iron source and the multiple reaction monitoring (MRM) (291.3 → 248.2m/z for azatadine, 383.3 → 337.3m/z for IS) was operated in positive ion modes. The low limit of quantitation (LLOQ) was 0.05 ng/mL. The intra-day and inter-day precision of the quality control (QC) samples was 8.93-11.57% relative standard deviation (RSD). The inter-day accuracy of the QC samples was 96.83-105.07% of the nominal values. 相似文献
10.
Weng W Xu H Huang J Wang G Shen T Zhang J 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2005,816(1-2):315-320
A sensitive and specific high-performance liquid chromatography (HPLC)-electrospray ionization tandem mass spectrometry (MS-MS) was developed for the determination of bulleyaconitine A (BLA) in human plasma. BLA and internal standard (I.S.) ketoconazole were extracted from the plasma by a liquid-liquid extraction. The supernatant was evaporated to complete dryness and reconstituted with acetonitrile containing 0.1% acetic acid before injecting into an ODS MS column. The gradient mobile phase was composed of a mixture of acetonitrile (containing 0.1% acetic acid, v/v) and 0.1% acetic acid aqueous solution eluted at 0.3 ml/min. BLA and I.S. were determined by multiple reaction monitoring using precursor-->product ion combinations at m/z 644.6-->584.3 and 531.2-->81.6, respectively. Linearity was established for the concentration range of 0.12-6 ng/ml. The recoveries of BLA ranged from 96.93 to 113.9% and the R.S.D. was within 20%. The method is rapid and applicable to the pharmacokinetic studies of BLA in human. 相似文献
11.
Wei G Xiao S Liu C 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,845(1):169-173
A rapid, sensitive and accurate liquid chromatographic-tandem mass spectrometric method is described for the determination of metolazone in human blood. Metolazone was extracted from blood using ethyl acetate and separated on a C18 column interfaced with a triple quadrupole tandem mass spectrometer. The mobile phase consisting of a mixture of acetonitrile, 10 mmol/l ammonium acetate and formic acid (60:40:0.1, v/v/v) was delivered at a flow rate of 0.5 ml/min. Electrospray ionization (ESI) source was operated in positive ion mode. Selected reaction monitoring (SRM) mode using the transitions of m/z 366-->m/z 259 and m/z 321-->m/z 275 were used to quantify metolazone and the lorazepam (internal standard), respectively. The linearity was obtained over the concentration range of 0.5-500 ng/ml for metolazone and the lower limit of quantitation (LLOQ) was 0.5 ng/ml. For each level of QC samples, inter- and intra-run precision was less than 8.07 and 3.56% (relative standard deviation (RSD)), respectively, and the bias was within +/-4.0%. This method was successfully applied to the pharmacokinetic study of metolazone formulation after oral administration to humans. 相似文献
12.
He X Batchelor TT Grossman S Supko JG;New Approaches to Brain Tumor Therapy 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2004,799(2):281-291
Procarbazine is a cytotoxic chemotherapeutic agent used in the treatment of lymphomas and brain tumors. Its pharmacokinetic behavior remains poorly understood even though more than 30 years have elapsed since the drug was approved for clinical use. To characterize the pharmacokinetics of procarbazine in brain cancer patients during a phase I trial, a method for determining the drug in human plasma by reversed-phase high-performance liquid chromatography (HPLC) with electrospray ionization mass spectrometry (ESI-MS) was developed and thoroughly validated. Plasma samples were prepared for analysis by precipitating proteins with trichloroacetic acid and washing the protein-free supernatant with methyl tert-butyl ether to remove excess acid. The solution was separated on a Luna C-18 analytical column using methanol-25 mM ammonium acetate buffer, pH 5.1 (22:78, v/v) as the mobile phase at 1.0 ml/min. A single-quadrupole mass spectrometer with an electrospray interface was operated in the selected-ion monitoring mode to detect the [M+H](+) ions at m/z 222.2 for procarbazine and at m/z 192.1 for the internal standard (3-dimethylamino-2-methylpropiophenone). Procarbazine and the internal standard eluted as sharp, symmetrical peaks with retention times (mean+/-S.D.) of 6.3+/-0.1 and 9.9+/-0.3 min, respectively. Calibration curves of procarbazine hydrochloride in human plasma at concentrations ranging from 0.5 to 50 ng/ml exhibited excellent linearity. The mean absolute recovery of the drug from plasma was 102.9+/-1.0%. Using a sample volume of 150 microl, procarbazine was determined at the 0.5 ng/ml (1.9 nM) lower limit of quantitation with a mean accuracy of 105.2% and an interday precision of 3.60% R.S.D. on 11 different days over 5 weeks. During this same time interval, the between-day accuracy for determining quality control solutions of the drug in plasma at concentrations of 2.0, 15 and 40 ng/ml ranged from 97.5 to 98.2% (mean+/-S.D., 97.9+/-0.4%) and the precision was 3.8-6.2% (mean+/-S.D., 5.1+/-1.2%). Stability characteristics of the drug were thoroughly evaluated to establish appropriate conditions to process, store and prepare clinical specimens for chromatographic analysis without inducing significant chemical degradation. The sensitivity achieved with this assay permitted the plasma concentration-time profile of the parent drug to be accurately defined following oral administration of standard doses to brain cancer patients. 相似文献
13.
Luca Ferrari Daniela ReamiMarco Michi 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(29):2974-2982
A sensitive, selective and quantitative method for the simultaneous determination of casopitant, a potent and selective antagonist of the human Neurokinin 1 (NK-1) receptor, and its three major metabolites M12, M13 and M31 was developed and validated in dog and rat plasma. Acetonitrile containing stable labeled internal standards for the four analytes was used to precipitate proteins in plasma. Chromatographic separation was obtained using a reversed phase column with multiple reaction monitoring turboionspray positive ion detection. The lower and upper limits of quantification for casopitant and its metabolites were 15 and 15,000 ng/mL, using a 50 μL of dog or rat plasma aliquot, respectively. The inter-day precision (relative standard deviation) and accuracy (relative error) in dog plasma, derived from the analysis of validation samples at 5 concentrations, ranged from 4.1% to 10.0% and −10.8% to 8.7%, respectively, for casopitant and its 3 major metabolites. The intra-day precision (relative standard deviation) and accuracy (relative error) in rat plasma, derived from the analysis of validation samples at 5 concentrations, ranged from 3.9% to 6.6% and −9.6% to 8.3%, respectively, for casopitant and its three metabolites. All analytes were found to be stable in analytical solutions for at least 43 days at 4 °C, in dog and rat plasma at room temperature for at least 24 h, at the storage temperature of −20 °C for at least 6 months, and following the action of three freeze–thaw cycles from −20 °C to room temperature. All analytes were also found to be stable in processed extracts at 4 °C for at least 72 h. This assay proved to be accurate, precise, fast and was used to support long-term toxicology studies in dog and rat. 相似文献
14.
Zou Y Chen X Song B Zhong D 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,852(1-2):122-127
A rapid and sensitive liquid chromatographic/tandem mass spectrometric method for determination of misoprostol acid, the active metabolite of misoprostol, was developed and validated. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a C(18) column. An API 4000 tandem mass spectrometer equipped with Turbo IonSpray ionization source was used as detector and was operated in the negative ion mode. Multiple reaction monitoring using the precursor to product ion combinations of m/z 367-249 and 296-269 was performed to quantify misoprostol acid and the internal standard hydrochlorothiazide, respectively. The method was linear in the concentration range of 10.0-3000 pg mL(-1) using 200 microL plasma. The lower limit of quantification was 10.0 pg mL(-1). The intra- and inter-day relative standard deviation over the entire concentration range was less than 8.3%. Accuracy determined at three concentrations (25.0, 200 and 2700 pg mL(-1) for misoprostol acid) ranged from -0.5 to 1.2% in terms of relative error. Each plasma sample was chromatographed within 3.5 min. The method was successfully used in a pharmacokinetic study of misoprostol in human plasma after an oral administration of 0.6 mg misoprostol. 相似文献
15.
Cai S Huo T Feng W Chen L Qin F Li F 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2008,868(1-2):83-87
A selective, rapid and sensitive ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) method was developed for the quantitative determination of mitiglinide in human plasma. With nateglinide as internal standard, sample pretreatment involved a one-step extraction with diethyl ether of 0.2 mL plasma. The separation was performed on an ACQUITY UPLCtrade mark BEH C(18) column (50 mm x 2.1 mm, i.d., 1.7 microm) with the mobile phase consisting of methanol and 10 mmol/L ammonium acetate (65:35, v/v) at a flow rate of 0.25 mL/min. The detection was carried out by means of electrospray ionization mass spectrometry in positive ion mode with multiple reaction monitoring (MRM). Linear calibration curves were obtained in the concentration range of 1.080-5400 ng/mL, with a lower limit of quantification of 1.080 ng/mL. The intra- and inter-day precision (RSD) values were below 15% and accuracy (RE) was from -3.5% to 7.3% at all QC levels. The method was fully validated and successfully applied to a clinical pharmacokinetic study of mitiglinide in 10 healthy volunteers following oral administration. 相似文献
16.
Wang R Wang G Hao H Xie H Zhang J Wu F 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2006,831(1-2):36-41
Atractylenolide III is a major active component in Atractylodes macrocephala. This paper describes a simple, rapid, specific and sensitive method for the quantification of atractylenolide III in rat plasma using a liquid-liquid extraction procedure followed by liquid chromatography mass spectrometric (LC-MS) analysis. A Kromasil 3.5 microm C(18) column (150 mm x 2.00 mm) was used as the analytical column. Linear detection responses were obtained for atractylenolide III concentration ranging from 5 to 500 ng L(-1). The precision and accuracy data, based on intra-day and inter-day variations over 5 days were within 10.29%. The lower limit of quantitation for atractylenolide III was 5 ng mL(-1), using 0.1 mL plasma for extraction and its recoveries were greater than 85% at the low, medium and high concentrations. The method has been successfully applied to a pharmacokinetic study in rats after an oral administration of atractylenolide III with a dose of 20.0 mg kg(-1). With the lower limits of quantification at 5 ng mL(-1) for atractylenolide III, this method was proved to be sensitive enough for the pharmacokinetics study of atractylenolide III. 相似文献
17.
Helene Stenhoff sa Blomqvist Per-Olof Lagerstrm 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1999,734(2):665
An enantioselective assay of omeprazole in blood plasma using normal-phase liquid chromatography on a Chiralpak AD column and detection by mass spectrometry is described. Omeprazole is extracted by a mixture of dichloromethane and hexane and, after evaporation, redissolution and injection, separated into its enantiomers on the chiral stationary phase. Detection is made by a triple quadrupole mass spectrometer, using deuterated analogues as internal standards. The method enables determination in plasma down to 10 nmol/l (LOQ) and shows excellent consistency suited for pharmacokinetic studies in man. 相似文献
18.
Lehtonen M Storvik M Malinen H Hyytiä P Lakso M Auriola S Wong G Callaway JC 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(11-12):677-694
A simple and highly sensitive liquid chromatography/tandem mass spectrometric (LC/MS/MS) method was developed to compare endogenous cannabinoid levels in nematodes and in brains of rats and humans, with and without prior exposure to ethanol. After liquid-liquid extraction of the lipid fraction from homogenized samples, a reversed-phase sub 2 μm column was used for separating analytes with an isocratic mobile phase. Deuterated internal standards were used in the analysis, and detection was made by triple quadrupole mass spectrometer with multiple reaction monitoring (MRM). Ionization was performed with positive electrospray ionization (ESI). The nematode Caenorhabditis elegans fat-3 mutant, that lacks the necessary enzyme to produce arachidonic acid, the biologic precursor to 2-arachidonoyl glycerol and anandamide, was used as an analyte-free surrogate material for selectivity and calibration studies. The matrix effect was further investigated by in-source multiple reaction monitoring (IS-MRM) and standard addition studies. Selectivity studies demonstrated that the method was free from matrix effects. Good accuracy and precision were obtained for concentrations within the calibration range of 0.4-70 nM and 40-11,000 nM for monitored N-acylethanolamides (NAEs) and acyl glycerols, respectively. 相似文献
19.
Zhan Y Chen X Zhong D 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(30):3353-3359
Quantitative analysis of peptides in biological matrices remains a challenging task. This is due to the low dosage and the complexity of both the matrix and the analytical characteristics of peptides. SS-20 is a tetrapeptide compound developed for the treatment of Parkinson's disease. To investigate the pharmacokinetics of SS-20, a sensitive and rapid liquid chromatography coupled with mass spectrometry method was developed and validated. An aliquot of 50 μL plasma sample was extracted via solid phase extraction. The extracts were separated using a hydrophilic interaction liquid chromatography column, and were then detected with a triple quadrupole mass spectrometer using electrospray ionization in positive-ion mode and selected reaction monitoring. The use of a deuterium-labeled internal standard provided acceptable accuracy, precision, and matrix effect. The lower limit of quantification was 0.30 ng/mL. The linear range of the method was from 0.30 to 1000 ng/mL. The intraday and interday precisions were lower than 10.2% in terms of relative standard deviation, and the accuracy was within ±2.1% in terms of relative error. The validated LC-MS/MS method was successfully applied to a pharmacokinetic study of SS-20 following an intravenous or subcutaneous injection administration of 1.0mg/kg to Sprague-Dawley rats. 相似文献
20.
Baughman TM Wright WL Hutton KA 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,852(1-2):505-511
A hydrophilic interaction chromatography (HILIC)/mass spectrometric assay was developed for the determination of zanamivir, a neuraminidase inhibitor used to treat influenza, in rat and monkey plasma. An organic solvent with hydrophilic properties, methanol, was used to precipitate proteins in plasma to assure the highly polar zanamivir of staying in solution. Chromatographic separation was obtained using a HILIC silica column with multiple reaction monitoring turboionspray positive ion detection. The stable label of zanamivir, [(13)C(1)(15)N(2)] GR121167C, was used as the internal standard. The assay was validated for the determination of zanamivir in rat and monkey plasma. The lower and upper limits of quantitation were 2 and 10000 ng/mL, using 0.05 mL plasma aliquot, respectively. The signal to noise ratio of a typical 2 ng/mL was approximately 5:1. The inter-day precision (relative standard deviation) and accuracy (relative error) in rat plasma, derived from the analysis of validation samples at 5 concentrations, ranged from 6 to 10% and -6.5 to 0.2%, respectively. The inter-day precision (relative standard deviation) and accuracy (relative error) in monkey plasma, derived from the analysis of validation samples at five concentrations, ranged from 2 to 8% and -2.3 to 2.1%, respectively. Zanamivir was found to be stable for at least 5 days at approximately -80 degrees C and at room temperature in plasma. This assay incorporates a simple protein precipitation with methanol and hydrophilic interaction chromatography which is sensitive, accurate, precise, and is being used to support oral formulation and toxicokinetic studies in rat and monkey, respectively. 相似文献