首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Rhodamine 123 (R123), as a typical of P-gp substrate, was widely used to quantify P-glycoprotein (P-gp) functional efflux activity in vivo. A new, rapid and sensitive method was developed for quantifying R123 in rat plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS). R123 and Rhodamine 6G (R6G, the internal standard, IS) were extracted from aliquots of plasma with ethyl acetate and dichloromethane (4:1) as the solvent and chromatographic separation was performed using a Zorbax Eclipse Plus C18 column. The mobile phase was composed of A: ammonium formate-formic acid buffer containing 5 mM ammonium formate and 0.1% formic acid and B: methanol (A:B, 5:95, v/v). To quantify R123 and IS respectively, multiple reaction monitoring (MRM) transition of m/z 345.2→285.2 and m/z 443.3→415.2 was performed. The analysis time was 4 min in positive mode; the calibration curve was linear in the concentration range of 1-200 ng/ml. The lowest limit of quantification (LLOQ) reached 1 ng/ml. The intra and inter-day precision were less than 9.2% for the low quality control (QC) level, and 3.4% for other QC levels, respectively, while the intra and inter-day relative errors ranged between -7.4% and 9.1% for three QC concentration levels. The LC-MS/MS method proved to be simple, accurate, reliable and with a shorter running time and has been successfully applied to evaluate the functional activity of P-glycoprotein in an absorption experiment in the rat.  相似文献   

2.
22Na+ uptake measurements were conducted on the dog kidney cell line, MDCK, to determine the mechanism of ouabain-insensitive sodium transport. The radioisotope was found to be taken up into monolayer cultures via an ATP-independent, saturable process (Km = 40 mM). The presence of sodium on the opposite side of the membrane gave rise to a transstimulation of the 22Na+ flux. Studies utilizing potassium and valinomycin suggested that the transport system was insensitive to changes in the membrane potential. Replacement of chloride in the assay buffer with other anions did not decrease the rate of 22Na+ uptake at 14 mMNa+, but bicarbonate and acetate were stimulatory. Potassium and rubidium increased the rate of 22Na+ influx (Ka = 13mM with 14 mM NaCL in the medium). Lithium (Ki = 7.5mM) and amiloride (Ki = 1.7 x 10(-5) M) were competitive and partially (or mixed) competitive inhibitors, respectively. The data are consistent with a mechanism of sodium uptake that includes a carrier(s) capable of catalyzing net sodium uptake and sodium-sodium exchange.  相似文献   

3.
A high-performance liquid chromatographic method for the determination of trimetazidine dihydrochloride (TMZ) in spiked human plasma is described. The method is based on the pre-column derivatization with 9-fluorenylmethyl chloroformate (FMOC-Cl) using the fluorimetric detection technique. Fluoxetine HCl (FLX) was used as internal standard. Both, TMZ and FLX were completely derivatized after heating at 50 degrees C for 20 min in borate buffer pH 8.0. Samples were analyzed by high performance liquid chromatography (HPLC) using Zorbax-TMS column (250 mm x 4.6 mm, i.d., 5 microm) and mobile phase consist of acetonitrile, methanol and 20 mM sodium acetate pH 4.7 (44:6:50; v/v/v). Fluorescence detector (FLD) was adjusted at excitation and emission wavelengths; 265 and 311 nm, respectively. The linearity of the method was in the range of 4.5-200 ng/ml. Limits of detection (LOD) and quantification (LOQ) were 1.5 and 4.5 ng/ml, respectively. Trimetazidine recovery was 96.5+/-1.3% (n=6; RSD=2.1%).  相似文献   

4.
A rapid, robust and sensitive HPLC method for analysis of uracil (U) and dihydrouracil (UH2) in plasma was developed using solid phase extraction and ultraviolet detection. Separation was achieved with a SymmetryShield RP18 column and an Atlantis dC18 column using a 10 mM potassium phosphate buffer as mobile phase. Compounds were eluted within 15 min without interference. Recovery was 80.4 and 80.6% for U and UH2. Calibration curves were linear from 2.5 to 80 ng/mL for U and 6.75 to 200 ng/mL for UH2. The LLQ was, respectively, 2.5 ng/mL for U, and 6.75 ng/mL for UH2. Within-run and between-run precision were less than 5.94% and inaccuracy did not exceed 7.80%. The overall procedure has been applied to correlate UH2/U ratio with dihydropyrimidine dehydrogenase activity in 165 cancer patients.  相似文献   

5.
A novel determination method for josamycin (JOS) based on capillary electrophoresis-electrochemiluminescence detection has been described. In this study, platinum disk electrode (300 microm in diameter) was used as a working electrode and the conditions affecting separation and detection were investigated in detail. Under optimal condition: 40 cm separation capillary (75 microm i.d.); 1.25 V applied potential on the Pt disc of the ECL detector cell; 5 mM Ru(bpy)3(2+) and 50mM phosphate buffer (pH 7.5) in the detection cell; 12 kV separation voltage; 8s injection time; 10 kV injection voltage and 15 mM running buffer (pH 7.5), calibration curve was linear over the range from 10 ng/mL to 5.0 microg/mL with a detection limit of 3.1 ng/mL at a signal-to-noise ratio of 3. The method can be successfully applied for the determination of josamycin in rat plasma in 6 min and the extraction recoveries with spiked plasma samples were over 92%.  相似文献   

6.
A simple high-performance liquid chromatography (HPLC) method has been developed and validated for the simultaneous determination of abacavir and zidovudine (AZT) in rat plasma, amniotic fluid, fetal, and placental tissues. Extraction of abacavir, AZT, and the internal standard, azidouridine (AZDU) in amniotic fluid was carried out by protein precipitation. Extraction from plasma, fetal and placental homogenates was achieved by using a salting out technique. Chromatographic separation was performed using a C8 column (150 mm x 4.6 mm, 5 microm). The mobile phase consisted of 12% acetonitrile in 25 mM sodium phosphate buffer (adjusted to pH 7 with sodium hydroxide) for the fetus, placenta, plasma and amniotic fluid samples at a flow rate of 0.8 mL/min. The method was validated over the range from 0.05 to 50 microg/mL for both abacavir and AZT in the four biological matrices. The absolute recovery of abacavir ranged from 79 to 94%, while AZT recoveries ranged from 79 to 90% in the different biological matrices. The internal standard recovery ranged from 90 to 92%. Acceptable intra- and inter-day assay precision (<10% R.S.D.) and accuracy (<10% error) were observed over 0.05-50 microg/mL for all four matrices.  相似文献   

7.
A new, simple, and reproducible isocratic high-performance liquid chromatography (HPLC) method has been developed for the determination of free and total tyrosine and tryptophan in a protein concentrate. To determine total amino acids, the method involves alkaline hydrolysis of the proteins with sodium hydroxide at 120 degrees C for 4h in the absence of air. Best results were achieved with a SS Exil ODS column 5microm (25cmx0.46cm i.d.), with an eluent of methanol: 40mM sodium acetate buffer (adjusted to pH 4.5 with acetic acid; 20:80, v/v), a flow rate of 0.80mL/min at 26 degrees C, and with programmable fluorescence detection. Under optimum conditions excellent linearity was obtained, and the overall recovery was 90.5, and 95.9% for total tryptophan and tyrosine, respectively. The precision results showed that the relative standard deviation of the repeatability and reproducibility were < or =4.78 and < or =4.65, respectively. This method was used to quantify the cited analytes in the protein concentrate obtained during the lactic acid fermentation of shrimp waste.  相似文献   

8.
This paper describes an HPLC method for the determination of tramadol and its major active metabolite, O-desmethyltramadol (ODT), in human plasma. Sample preparation involved liquid-liquid extraction with diethyl ether-dichloromethane-butanol (5:3:2, v/v/v) and back extraction with sulphuric acid. Tramadol, ODT and the internal standard, sotalol, were separated by reversed phase HPLC using 35% acetonitrile and an aqueous solution containing 20 mM sodium phosphate buffer, 30 mM sodium dodecyl sulphate and 15 mM tetraethylammonium bromide pH 3.9. Detection was by fluorescence with excitation and emission wavelengths of 275 and 300 nm, respectively. The method was linear for tramadol (3-768 ng/ml) and ODT (1.5-384 ng/ml) with mean recoveries of 87.2% and 89.8%, respectively. Intra- and inter-day precisions were 10.34% and 8.43% for tramadol and 9.43% and 8.75% for ODT at the respective limits of quantitation (3 and 1.5 ng/ml). Accuracy for tramadol ranged from 96.2% to 105.3%. The method was applied to a pharmacokinetic study of tramadol in human volunteers.  相似文献   

9.
Capillary zone electrophoresis was optimized to quantitatively determine codeine and paracetamol via central composite factorial design. Critical parameters (concentration, buffer, pH, voltage) assessed effects on resolution, analysis time and efficiencies. Optimum separation conditions were achieved using phosphate buffer 20 mM (pH 6.8) and voltage (15 kV). The optimized procedure easily determined codeine and paracetamol with separation in less than 3 min. Calibration curves (R > 0.999) were prepared, with LODs of 13.5 and 340 ng mL(-1) for codeine and paracetamol, respectively, and a good R.S.D.% (<3%). This method was applied to determine codeine and paracetamol in pharmaceutical formulations; recoveries coincided with stated contents.  相似文献   

10.
Our goal was to quantify mitochondrial and plasma potential (Δψ(m) and Δψ(p)) based on the disposition of rhodamine 123 (R123) or tetramethylrhodamine ethyl ester (TMRE) in the medium surrounding pulmonary endothelial cells. Dyes were added to the medium, and their concentrations in extracellular medium ([R(e)]) were measured over time. R123 [R(e)] fell from 10 nM to 6.6 ± 0.1 (SE) nM over 120 min. TMRE [R(e)] fell from 20 nM to a steady state of 4.9 ± 0.4 nM after ~30 min. Protonophore or high K(+) concentration ([K(+)]), used to manipulate contributions of membrane potentials, attenuated decreases in [R(e)], and P-glycoprotein (Pgp) inhibition had the opposite effect, demonstrating the qualitative impact of these processes on [R(e)]. A kinetic model incorporating a modified Goldman-Hodgkin-Katz model was fit to [R(e)] vs. time data for R123 and TMRE, respectively, under various conditions to obtain (means ± 95% confidence intervals) Δψ(m) (-130 ± 7 and -133 ± 4 mV), Δψ(p) (-36 ± 4 and -49 ± 4 mV), and a Pgp activity parameter (K(Pgp), 25 ± 5 and 51 ± 11 μl/min). The higher membrane permeability of TMRE also allowed application of steady-state analysis to obtain Δψ(m) (-124 ± 6 mV). The consistency of kinetic parameter values obtained from R123 and TMRE data demonstrates the utility of this experimental and theoretical approach for quantifying intact cell Δψ(m) and Δψ(p.) Finally, steady-state analysis revealed that although room air- and hyperoxia-exposed (95% O(2) for 48 h) cells have equivalent resting Δψ(m), hyperoxic cell Δψ(m) was more sensitive to depolarization with protonophore, consistent with previous observations of pulmonary endothelial hyperoxia-induced mitochondrial dysfunction.  相似文献   

11.
A new, selective and sensitive high-performance liquid chromatography (HPLC) method with fluorimetric detection was developed for the determination of tianeptine (TIA) in human plasma using solid phase extraction (SPE) procedures. The method is based on the derivatization of TIA with 4-chloro-7-nitrobenzofurazan (NBD-Cl) in borate buffer of pH 8.5 to yield a yellow, fluorescent product. The HPLC separation was achieved on a Phenomenex C(18) column (250 mm x 4.6 mm) using a mobile phase of acetonitrile-10mM orthophosphoric acid (pH 2.5) (77:23, v/v) solvent system at 1 mL/min flow rate. Gabapentin (GA) was used as the internal standard. The fluorometric detector was operated at 458 nm (excitation) and 520 nm (emission). The assay was linear over the concentration range of 5-300 ng/mL. The detection limit (LOD) was found to be 2 ng/mL. The mean recovery was determined to be 88.6%. The proposed method was applied for pharmacokinetic study of 12.5mg TIA in a healthy volunteer.  相似文献   

12.
Zalcitabine (ddC), lamivudine (3TC), didanosine (ddI), stavudine (d4T), carbovir (CBV), zidovudine (AZT), tenofovir (PMPA) and its administrated form (tenofovir diisoproxyl fumarate, TDF), are nucleosides currently approved in HIV therapy. To facilitate pharmacokinetics studies, a specific reversed-phase high-performance liquid chromatography (HPLC) method was developed for their analysis in rat plasma. The method involved a quantitative recovery of these drugs from rat plasma by solid-phase extraction on Oasis HLB Waters cartridges followed by optimised HPLC separation on an Atlantis dC18 column with acetic acid-hydroxylamine buffer (ionic strength 5mM, pH 7)-acetonitrile elution gradient. Quantitation was performed by HPLC/UV at 260 nm. Linear calibration curves were obtained within a 30-10,000 ng/mL plasma concentration range. Correlation coefficients (r2) greater than 0.992 were obtained by least-squares regression and limits of quantification were in 30-90 ng/mL concentration range. Quantitative parameters (accuracy, intra-day repeatability and inter-day reproducibility) yielded satisfactory results. Finally, a new buffer, obtained with acetic acid and hydroxylamine, has been tested in HPLC/ESI-MS/MS and appears to be an efficient volatile buffer in the medium 5-7 pH range. Indeed, at pH 7 and low ionic strength (5 mM), its buffer capacity is one hundred times higher to that obtained for the usual acetic acid/ammonia buffer.  相似文献   

13.
A kinetic study of Rhodamine123 pumping by P-glycoprotein   总被引:1,自引:0,他引:1  
The MDR1 P-glycoprotein (P-gp) actively extrudes a wide variety of structurally diverse cytotoxic compounds out of the cell, is widely expressed in the epithelial cells of kidney, liver and intestine, and in the endothelial cells of brain and placenta, and plays an important role in drug resistance. We measured the accumulation of Rhodamine 123 (Rho123), a substrate of P-gp, into a drug sensitive and a drug resistant strain of the human leukemia cell line K562, as function of Rho123 concentration. With the aid of a mathematical transformation, we used the accumulation of Rho123 into the sensitive cells as a surrogate measure for the internal concentration of the probe in the resistant cells, and were thus able to measure the kinetic parameters of drug efflux pumping by P-gp. Drug pumping was half-saturated at an external Rho123 concentration of 7.2E-06+/-1.1E-06 M, and displayed a co-operative behaviour with a Hill number of 1.94+/-0.32. Verapamil could be shown to inhibit Rho123 efflux uncompetitively.  相似文献   

14.
A reverse‐phase high‐performance liquid chromatographic (RP‐HPLC) method was developed and validated for the simultaneous estimation of levodopa and carbidopa in bulk and pharmaceutical formulations. Chromatographic separation was achieved by using a C18 reverse‐phase column and a mixture of an aqueous phase (10 mM potassium dihydrogen phosphate buffer, pH 4.0) and methanol (90:10 v/v) as the mobile phase. Quantitative analysis of levodopa and carbidopa was performed using a fluorescence detector at an excitation wavelength of 280 nm and an emission wavelength of 310 nm. The method was linear between 5 and 500 ng/mL for both levodopa and carbidopa. The detection limits for levodopa and carbidopa were 0.30 and 0.60 ng/mL, respectively, whereas the quantitation limit was 0.80 ng/mL for levodopa and 1.2 ng/mL for carbidopa. The method demonstrated good and consistent recoveries (99.63–100.80% for levodopa and 98.97–100.94% for carbidopa) with low interday and intraday relative standard deviation. The validated method was successfully applied to quantify levodopa and carbidopa simultaneously in a pharmaceutical formulation. The method was found to be precise, sensitive and accurate for the simultaneous determination levodopa and carbidopa in bulk and pharmaceutical formulations. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

15.
An assay was developed to quantify norepinephrine (NE) and its metabolites (MHPG and DHPG) by high-performance liquid chromatography with electrochemical detection method (HPLC-ECD) in brain tissue and plasma of rats treated by LiCl. Separation on C(18) column was obtained by a mobile phase consisting of 4.5% methanol in buffer (0.1 M sodium acetate, 0.2 M citric acid) containing 0.2 mM ethylenediaminetetraacetic acid disodium salt (EDTA Na(2)) and 0.4 mM sodium octylsulfate, operated at a flow rate of 0.8 ml/min. A potential of +0.78 V was applied across the working and reference electrodes of the detector. The precision was in the range 2.88-4.35% for NE, 5.94-11.0% for MHPG and 1.97-4.40% for DHPG. Accuracy was 98.8-99.3% for NE, 97.4-100% for MHPG and 96.1-101% for DHPG. The limit of detection was 0.6 ng/ml for NE, 0.5 ng/ml for MHPG and 0.2 ng/ml for DHPG. The linearity is over the range 20-60 ng/ml for NE, 7-23 ng/ml for MHPG and 6-20 ng/ml for DHPG. The assay has been applied successfully to measure simultaneously cortex and plasmas concentrations of these three catecholamines in rats.  相似文献   

16.
The micellar electrokinetic chromatographic (MEKC) separation of seven bisbenzylisoquinoline alkaloids has been developed. The effects of various separating factors were studied. Optimum separation was achieved using a buffer (pH 9.2) of 20 mM sodium borate and 20 mM sodium dihydrogen phosphate buffer containing 55 mM sodium cholate; the optimum voltage and injection time were 21 kV and 0.05 min, respectively. Highest peak efficiency was obtained when the analytes were dissolved in 10 mM sodium dodecyl sulphate as sample matrix for injection. The elution order of the bisbenzylisoquinoline alkaloids was related to their lipophilicity. The resolution, run time and detection limits of the MEKC method were compared with those of an HPLC method developed previously.  相似文献   

17.
The stereoselective determination of stereoisomers in biological samples provides vital information on stereospecific metabolism and pharmacokinetic profiles of the drugs. Despite the unique advantage and the great success of normal-phase (NP) HPLC for the separations of drug stereoisomers using polysaccharide-type chiral stationary phases (CSPs), the technique is rarely applied to quantitative HPLC-MS-MS bioanalysis. This is, at least in part, due to the incompatibility between the usual mobile phase (n-hexane or n-heptane) in normal-phase HPLC and the MS ionization sources which poses a potential detonation hazard. An environmentally friendly and nonflammable alternative solvent, ethoxynonafluorobutane (ENFB), was reported previously to potentially provide an ideal solution for combining the powers of stereoselective NP chromatographic separation and MS-MS detection. In this study, a stereoselective NP-HPLC-MS-MS method was developed using ENFB to quantify a pair of Bristol Myers Squibb (BMS) proprietary drug stereoisomers and their ketone metabolite for an in vitro study, which demonstrated, for the first time, the practical applicability and utility of ENFB for bioanalysis in pharmaceutical industry. The effects of different organic modifiers and temperature, as well as the comparison between ENFB and the usual solvent, heptane, for the separation, are discussed. The resolution of the stereoisomers was achieved using 63% of 3:1 mixture of ethanol and methanol with 37% ENFB on a Chiralpak AD-H column at 50 degrees C. High sensitivity was obtained using the MS-MS detection in the positive ion atmospheric pressure chemical ionization (APCI) mode. The lower limit of quantitation (LLOQ) for the first stereoisomer and the ketone metabolite was 5 ng/mL, and was 10 ng/mL for the second isomer in the human liver microsome-potassium phosphate buffer matrix. The linear dynamic range of 5-1000 ng/mL for both isomers and 10-1000 ng/mL for the metabolite were demonstrated with R2 > or =0.997. The precision of the analysis was <5% R.S.D. at or above the nominal concentration of 80 ng/mL, and <20% R.S.D. at 8 ng/mL. The mean bias was less than 15%. Extraction recovery and acceptable matrix interference were demonstrated using one isomer and the ketone, and better than 75% recovery and less than 25% ion suppression or interference were found. The method was successfully implemented for an in vitro intrinsic metabolic clearance study.  相似文献   

18.
A reliable method has been developed for the determination of pyronaridine in human urine using amodiaquine as an internal standard. Liquid-liquid extraction was used for sample preparation. Analysis was performed on a Shimadzu LCMS-2010 in single ion monitoring positive mode using atmospheric pressure chemical ionization (APCI) as an interface. The extracted ion for pyronaridine was m/z 518.20 and for amodiaquine was m/z 356.10. Chromatography was carried out using a Gemini 5 microm C18 3.0 mmx150 mm column using 2 mM perflurooctanoic acid and acetonitrile mixture as a mobile phase delivered at a flow rate of 0.5 mL/min. The mobile phase was delivered in gradient mode. The retention times of pyronaridine and amodiaquine were 9.1 and 8.1 min respectively, with a total run time of 14 min. The assay was linear over a range of 14.3-1425 ng/mL for pyronaridine (R2>or=0.992, weighted 1/Concentration). The analysis of quality control samples for pyronaridine at 28.5, 285, 684 and 1140 ng/mL demonstrated excellent precision with relative standard deviation of 5.1, 2.3, 3.9 and 9.2%, respectively (n=5). Recoveries at concentrations of 28.5, 285, 684 and 1140 ng/mL were all greater than 85%.This LC-MS method for the determination of pyronaridine in human urine has excellent specifications for sensitivity, reproducibility and accuracy and can reliably quantitate concentrations of pyronaridine in urine as low as 14.3 ng/mL. The method will be used to quantify pyronaridine in human urine for pharmacokinetic and drug safety studies.  相似文献   

19.
A simple, rapid and validated high performance liquid chromatography method with UV detection for the quantification of an opioid agonist, fentanyl (FEN), in rat plasma was developed. The assay procedure involved chromatographic separation using a ZIC-HILIC SeQUANT column (250 mm × 4.6 mm, i.d., 5 μm) and a mobile phase of acetonitrile and acetate buffer (pH 3.4, 20mM) of ratio (=65:35, v/v) at a flow rate of 1.2 mL/min and detection wavelength of 201 nm. Plasma sample (100 μL) pretreatment was based on simple deprotienization by acetonitrile spiked with clonidine as an internal standard (I.S.) of 20 ng/mL followed by extraction with tert-butyl methyl ether and centrifugation. The organic layer was evaporated under N(2) gas and reconstituted with 100 μL of acetate buffer (pH 3.4, 20mM), and 50-μL portions of reconstituted sample were injected onto the column. Sample analysis including sample pretreatment was achieved within 35 min. Calibration curve was linear (r ≥ 0.998) from 5 to 100 ng/mL. Both intra- and inter-day assay precisions that are presented through RSD were lower than 12.6% for intra-day and lower than 12.0% for inter-day assessment. Limit of detection was 0.8 ng/mL at S/N of 3. This method was omitting the use of expensive solid phase extraction and time consuming liquid extraction procedures. Moreover, the present method was successfully applied to study pharmacokinetic parameters of FEN after intraperitoneal administration to male Wistar rat. Pharmacokinetic parameters estimated by using moment analysis were T(1/2) 198.3 ± 44.7 min, T(max) 28.3 ± 2.9 min and AUC(0-180) 15.6 ± 2.9(× 10(2))ngmin/mL.  相似文献   

20.
Resistance to chemotherapeutic agents in neoplastic cells is often mediated by expression of P-glycoprotein, which functions as a drug- efflux pump for a broad range of substrates. We have used a combination of patch clamp and video-imaging techniques to examine the expression and drug-efflux function of P-glycoprotein and to determine the possible correlation with swelling-activated chloride channels in drug- sensitive and -resistant cell lines. Two pairs of cell lines were used in these experiments: (a) control NIH-3T3 cells and a corresponding MDR1-transfectant; and (b) control 8226 myeloma cells and a derivative cell line selected for resistance to chemotherapeutic agents. Control cells lacked detectable P-glycoprotein expression based on Western blotting, immunofluorescence staining with a specific monoclonal antibody, and a functional assay of rhodamine-123 (R123) efflux. Resistant cells expressed P-glycoprotein at high levels and rapidly exported R123. During whole-cell recording using either hyperosmotic pipette solution or hypoosmotic Ringer solution, cell swelling was accompanied by Cl- channel opening in all four cell lines. The rates of induction, biophysical properties and magnitudes of Cl conductance (gCl) were indistinguishable between control and corresponding multidrug-resistant cells: gCl reached 0.96 +/- 0.31 (n = 14) and 0.83 +/- 0.31 nS/pF (mean +/- SD; n = 31) in NIH-3T3 and NIH-3T3/MDR cells, respectively; and 0.31 +/- 0.20 (n = 9) and 0.37 +/- 0.22 nS/pF (n = 7) in 8226 and 8226/Dox40 cells, respectively. gCl exhibited moderate outward rectification in symmetrical Cl- solutions, with a rectification ratio of 1.4 at +/- 50 mV. Cl- channels slowly closed during strong depolarization beyond +60 mV. Using video-imaging techniques with SPQ as a fluorescent probe, we monitored Cl(-)-channel opening in intact drug-sensitive and -resistant cells. gCl, measured either with whole-cell recording or SPQ imaging, was blocked by DIDS (voltage-dependent Kd < 50 microM at +40 mV), NPPB (Kd approximately 30 microM), and tamoxifen (complete and irreversible block approximately 10 microM). None of these blockers inhibited R123 efflux. NPPB accelerated R123 efflux, an effect that was mimicked by CCP, a mitochondrial uncoupler. In contrast, verapamil selectively blocked R123 efflux (Kd = 0.3 to 0.5 microM); 10 microM left gCl unaltered. Induction of gCl was not affected by vincristine or doxorubicin in the pipette solution. Moreover, the rate of R123 efflux did not change during cell swelling. We conclude that P-glycoprotein and swelling- activated chloride channels function independently and are separable by expression and by pharmacological sensitivities.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号