首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Static displacements in Pacinian corpuscles (PCs) were measured using video microscopy. Mechanical stimuli of 10-40 microm steps were applied to the PC capsule surfaces using cylindrical contacts with different diameters. Displacements parallel to the stimulation axis were measured at various locations in the focal plane of the optical setup. In contrast to previous data in the literature, the displacements within the corpuscle were found to be linearly related to the indentation amplitude. Displacements decreased as a function of lamella depth, with a more negative slope close to the surface and less negative slope at deeper locations. The experimental data were compared to the predictions of a previous mechanical model, and to the results of two new models: (1) elastic semi-infinite continuum model; (2) ovoid isotropic finite-element model. Although the previous model did not specify displacement boundary conditions, it predicted the current experimental results well. On the other hand, the experimental displacements were found to be smaller than those predicted by the semi-infinite continuum and finite-element models. However, both semi-infinite continuum and finite-element models yielded close results, which show that the three-dimensional ovoid geometry of the corpuscle is not the primary factor for determining the displacements in physiological conditions. Furthermore, simulations with the finite-element model using a wide range of material properties yielded similar results. This supports the hypothesis that a homogeneous isotropic model for the PC cannot predict experimental results. The modeling analyses suggest that the experimental results are largely affected by the displacement of the incompressible interlamellar fluid and the layered structure of the corpuscle.  相似文献   

2.
Static displacements in Pacinian corpuscles (PCs) were measured using video microscopy. Mechanical stimuli of 10–40?µm steps were applied to the PC capsule surfaces using cylindrical contactors with different diameters. Displacements parallel to the stimulation axis were measured at various locations in the focal plane of the optical setup. In contrast to previous data in the literature, the displacements within the corpuscle were found to be linearly related to the indentation amplitude. Displacements decreased as a function of lamella depth, with a more negative slope close to the surface and less negative slope at deeper locations. The experimental data were compared to the predictions of a previous mechanical model, and to the results of two new models: () elastic semi-infinite continuum model; () ovoid isotropic finite-element model. Although the previous model did not specify displacement boundary conditions, it predicted the current experimental results well. On the other hand, the experimental displacements were found to be smaller than those predicted by the semi-infinite continuum and finite-element models. However, both semi-infinite continuum and finite-element models yielded close results, which show that the three-dimensional ovoid geometry of the corpuscle is not the primary factor for determining the displacements in physiological conditions. Furthermore, simulations with the finite-element model using a wide range of material properties yielded similar results. This supports the hypothesis that a homogeneous isotropic model for the PC cannot predict experimental results. The modeling analyses suggest that the experimental results are largely affected by the displacement of the incompressible interlamellar fluid and the layered structure of the corpuscle.  相似文献   

3.
目的:探讨Begg矫治器和直丝弓矫治器联合治疗安氏Ⅱ类1分类错颌畸形的临床疗效。方法:采取回顾性分析方法,调阅2010-2013年徐州矿务集团总医院安氏Ⅱ类1分类错颌畸形患者病历资料,选择病历资料完整且符合本研究要求的正畸病人病历44例进行分析,实验组22例为Begg矫治器和直丝弓矫治器联合治疗组,对照组22例为单纯直丝弓治疗组。对治疗前后的头影测量片进行扫描分析,对治疗时间及辅助支抗应用情况进行统计分析。结果:治疗完成时,Begg矫治器和直丝弓矫治器联合治疗组和单纯直丝弓治疗组的前牙覆合覆盖均减少,上切牙切缘均向远中移动,上下磨牙均伸长,前下面高度均增加,两组治疗结束后硬组织的变化无统计学差异(P0.05)。Begg矫治器和直丝弓矫治器联合治疗组与单纯直丝弓治疗组相比,治疗时间短,使用辅助支抗少,差异具有统计学意义(P0.05)。结论:Begg矫治器和直丝弓矫治器联合矫治安氏Ⅱ类1分类错颌畸形是临床上一种速度快,费用低,效果优的治疗方法。  相似文献   

4.
Delamination of the veneering composite is frequently encountered with fibre-reinforced composite (FRC) fixed dental prosthesis (FDPs). The aim of this study is to evaluate the influence of framework design on the load-bearing capacity of laboratory-made three-unit inlay-retained FRC-FDPs. Inlay-retained FRC-FDPs replacing a lower first molar were constructed. Seven framework designs were evaluated: PFC, made of particulate filler composite (PFC) without fibre-reinforcement; FRC1, one bundle of unidirectional FRC; FRC2, two bundles of unidirectional FRC; FRC3, two bundles of unidirectional FRC covered by two pieces of short unidirectional FRC placed perpendicular to the main framework; SFRC1, two bundles of unidirectional FRC covered by new experimental short random-orientated FRC (S-FRC) and veneered with 1.5 mm of PFC; SFRC2, completely made of S-FRC; SFRC3, two bundles of unidirectional FRC covered by S-FRC. Load-bearing capacity was determined for two loading conditions (n=6): central fossa loading and buccal cusp loading. FRC-FDPs with a modified framework design made of unidirectional FRC and S-FRC exhibited a significant higher load-bearing capacity (p<0.05) (927±74 N) than FRC-FDPs with a conventional framework design (609±119 N) and PFC-FDPs (702±86 N). Central fossa loading allowed significant higher load-bearing capacities than buccal cusp loading. This study revealed that all S-FRC frameworks exhibited comparable or higher load-bearing capacity in comparison to an already established improved framework design. So S-FRC seems to be a viable material for improving the framework of FRC-FDPs. Highest load-bearing capacity was observed with FRC frameworks made of a combination of unidirectional FRC and S-FRC.  相似文献   

5.
We measured relative displacement of the rib cage (RC) and abdomen (ABD) in 12 anesthetized rabbits during forced oscillations. Sinusoidal volume changes were delivered through a tracheostomy at frequencies from 0.5 to 30 Hz and measured by body plethysmography. Displacements of the RC and ABD were measured by inductive plethysmography. During oscillation at fixed tidal volume (VT = 1.3 ml/kg) the ratio ABD/RC, normalized to unity at 0.5 Hz, was 0.88 +/- 0.06 at 2 Hz and increased to 1.28 +/- 0.13 at 6 Hz (P less than 0.01). As frequency increased further ABD/RC fell sharply but between 20 and 30 Hz reached a plateau of 0.17 +/- 0.02 (P less than 0.001). Displacements of RC and ABD were nearly synchronous from 0.5 to 2 Hz, but as frequency increased ABD lagged RC progressively, reaching a phase difference of 90 degrees between 6 and 8 Hz and 180 degrees between 16 and 20 Hz. In six additional rabbits we measured chest wall displacements while varying VT from 0.5 to 3.7 ml/kg. ABD/RC was independent of VT at low frequencies (less than or equal to 6 Hz) but fell sharply with increasing VT at the higher frequencies. We interpreted these findings using a chest wall model having an RC compartment whose displacements are governed primarily by a nonlinear compliance, in parallel with an ABD compartment whose displacements are governed by a series resistance, inertance, and in addition a nonlinear compliance. The experimental findings are in large measure accounted for by such a model if the degree of nonlinearity of ABD and RC compliances are comparable.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

6.
Displacements of single one-headed myosin molecules in a sparse myosin-rod cofilament were measured from bead displacements at various angles relative to an actin filament by dual optical trapping nanometry. The sparse myosin-rod cofilaments, 5-8 micron long, were synthesized by slowly mixing one-headed myosin prepared by papain digestion with myosin rods at molar ratios of 1:400 to 1:1500, so that one to four one-headed myosin molecules were on average scattered along the cofilament. The bead displacement was approximately 10 nm at low loads ( approximately 0.5 pN) and at angles of 5-10 degrees between the actin and myosin filaments (near physiologically correct orientation). The bead displacement decreased with an increase in the angle. The bead displacement at nearly 90 degrees was approximately 0 nm. When the angle was increased to approximately 150 degrees-170 degrees, the bead displacements increased to 5 nm. A native two-headed myosin showed similar size and orientation dependence of bead displacements as a one-headed myosin.  相似文献   

7.
目的:比较氧化锆全瓷修复与金属烤瓷修复在前牙牙冠延长术后冠修复中的应用效果及安全性。方法:选取2016年7月~2018年7月我院收治的择期行前牙牙冠延长术后冠修复的患者80例(共97颗上颌牙),采用随机数字表法将患者分为两组,对照组40例(48颗患牙)采用金属烤瓷修复,观察组40例(49颗患牙)采用氧化锆全瓷修复。比较两组患者的牙体修复效果和牙周修复效果,治疗前后龈沟出血指数(sulcus bleeding index,SBI)、松动度(movable degree,MD)和菌斑指数(plaque index,PI)的变化以及不良反应的发生情况。结果:治疗后,观察组临床治疗总有效率显著高于对照组(87.76%vs.70.83%,P<0.05);观察组患者的边缘密合度、牙体折损、牙体颜色和牙龈健康状况均显著优于对照组(P<0.05);两组患者治疗后的SBI、MD和PI均较治疗前显著下降,且观察组以上指标显著低于对照组(P<0.05)。观察组患者不良反应发生率显著低于对照组(P<0.05)。结论:氧化锆全瓷修复用于前牙牙冠延长术后冠修复的临床效果显著优于金属烤瓷修复,且安全性更高。  相似文献   

8.
A treatment is presented which quantitates deformation of thin-walled, mildly tapered or untapered vessels having oval cross sections in the unstressed state. The discussion is limited to the quasi-static case and provides a basis for further work involving dynamic contributions and wall coupling. Results are presented for mathematical models and it is shown that the elastic constants and dimensions have significant and often profound effects especially during the initial transmural loading phase. Displacements of the major and minor semi-axes may be unequal and in different directions. These effects are more pronounced with greater eccentricity and with thinner walls. The resultants of extensible and inextensible strain combinations determine the displacements at the semi-axes. In unrestrained vessels, the resulting wall displacement can be predicted from a knowledge of the elastic constants and the principal dimensions, by determining the effective stresses at the semi-axes. This project was supported by Grants USPHS-HE-4885 and HE 10,330,04.  相似文献   

9.
Biomechanical investigations are yet necessary to better understand the origin of the gleno?d loosening which is the main reason for revision surgery. The aim of this study was to analyse the behaviour of cadaveric gleno?ds before and after implantation of gleno?d prostheses. For that, we developed a new experimental protocol allowing measurement of bone strains and implants displacements under various loading cases. Ten pairs of fresh cadaveric scapulae were tested. Two kinds of loads were applied on the intact gleno?d: physiological loads corresponding to a 0-180 degrees abduction and anteflexion movements, and 500N loads. The gleno?ds were then implanted with a keeled or pegged cemented polyethylene implant. The same previous 500N loads were then applied on the implanted gleno?ds. Strains were measured using six strain gages placed on precise points around the peripheral cortex of the gleno?d. Displacements of implants under loading were measured using two CCD cameras. Maximum strains were obtained between 60 degrees and 120 degrees of abduction or anteflexion. They were located at the anterior and antero-superior parts of the gleno?d during abduction and at the posterior and postero-superior parts during anteflexion. Implantation of a prosthetic component generally seemed to increase strains, but tensile strains were decreased at the postero-inferior part with the antero-inferior loading point.Some differences were observed between the implants, but they have to be confirmed by further experiments. The great number of data obtained for intact scapulae could be used for a better understanding of gleno?d behaviour and for validation of finite element models.  相似文献   

10.
生物医药领域近年来发展迅猛,多肽类药物因其生物学活性高、毒性小、生物相容性好等优势,在肿瘤治疗、细胞活性模拟、抗体检测等领域展开广泛应用,多肽的检测分析也成为研究的一大热点。传统的色谱法、溶剂沉淀法、离心超滤法和固相萃取法对多肽能够展现富集效果,但富集的效率往往不够理想。近年来,以有机框架材料为代表的纳米材料,在气体吸附、荧光、传感和催化等领域展开了广泛应用。有机框架材料凭借着独特的结构尺寸,成为了一类理想的生物吸附剂。由于其具有表面可修饰性,能够大大提高对多肽的富集效率。本文着重介绍近5年来金属-有机框架材料(metalorganic frameworks,MOFs)和共价-有机框架(covalent-organic frameworks,COFs)在多肽富集中的应用。  相似文献   

11.
In recent years metal-free ceramic systems have become increasingly popular in dental practice because of their superior aesthetics, chemical durability and biocompatibility. Recently, manufacturers have proposed new dental ceramic systems that are advertised as being suitable for posterior fixed partial dentures (FPDs). Reports indicate that some of these systems have exhibited poor clinical performance. The objective of this study was to use the viscoelastic option of the ANSYS finite element program to calculate residual stresses in an all-ceramic FPD for four ceramic-ceramic combinations. A three-dimensional finite element model of the FPD was constructed from digitized scanning data and calculations were performed for four systems: (1) IPS Empress 2, a glass-veneering material, and Empress 2 core ceramic; (2) IPS Eris a low fusing fluorapatite-containing glass-veneering ceramic, and Empress 2 core ceramic; (3) IPS Empress 2 veneer and an experimental lithium-disilicate-based core ceramic; and (4) IPS Eris and an experimental lithium-disilicate-based core ceramic. The maximum residual tensile stresses in the veneer layer for these combinations are as follows: (1) 77 MPa, (2) 108 MPa, (3) 79 MPa, and (4) 100 MPa. These stresses are relatively high compared to the flexural strengths of these materials. In all cases, the maximum residual tensile stresses in the core frameworks were well below the flexural strengths of these materials. We conclude that the high residual tensile stresses in all-ceramic FPDs with a layering ceramic may place these systems in jeopardy of failure under occlusal loading in the oral cavity.  相似文献   

12.
We describe a novel synchronous detection approach to map the transmission of mechanical stresses within the cytoplasm of an adherent cell. Using fluorescent protein-labeled mitochondria or cytoskeletal components as fiducial markers, we measured displacements and computed stresses in the cytoskeleton of a living cell plated on extracellular matrix molecules that arise in response to a small, external localized oscillatory load applied to transmembrane receptors on the apical cell surface. Induced synchronous displacements, stresses, and phase lags were found to be concentrated at sites quite remote from the localized load and were modulated by the preexisting tensile stress (prestress) in the cytoskeleton. Stresses applied at the apical surface also resulted in displacements of focal adhesion sites at the cell base. Cytoskeletal anisotropy was revealed by differential phase lags in X vs. Y directions. Displacements and stresses in the cytoskeleton of a cell plated on poly-L-lysine decayed quickly and were not concentrated at remote sites. These data indicate that mechanical forces are transferred across discrete cytoskeletal elements over long distances through the cytoplasm in the living adherent cell. mechanical forces; deformation; focal adhesion; microfilament  相似文献   

13.
The set of three pair atom–atom potentials for zirconia crystals and nano objects was developed. Besides Buckingham potential and Coulomb interaction, these force fields employ the additional functional forms: Fermi-Dirac, Inverse Gaussian or Morse potential. The developed force fields are capable to reproduce the structural, mechanical and thermodynamic properties of five zirconia phases: monoclinic, tetragonal, cubic, brookite and cotunnite with acceptable accuracy. The proposed force fields give monoclinic phase as a ground state structure and predict the correct energy ordering of the phases. The Raman and IR phonon frequencies, temperature dependencies of the thermodynamic properties of monoclinic and tetragonal zirconia are predicted in good and moderate agreement with the experimentally observed data and results of first-principles calculations. To test the transferability of proposed potentials, the zirconia-based nanosheets and nanotubes were simulated. Results of structure optimisation and calculation of the nanotubes’ strain energies are well compared with the corresponding data of the first-principles calculations.  相似文献   

14.
摘要 目的:探讨纤维桩、纳米复合树脂结合氧化锆烤瓷冠对根管治疗后后牙楔状缺损患者美学效果及牙周组织的影响。方法:选取2018年1月至2019年3月期间我院收治的103例患者作为研究对象,按修复材料的不同分为对照组(n=52,患牙62颗)和研究组(n=51,患牙63颗)。对照组给予金属桩核、金属烤瓷冠修复,研究组给予纤维桩、纳米复合树脂结合氧化锆烤瓷冠修复。修复1年后,评价两组的修复成功率和修复效果。比较两组修复前及修复后1年的牙龈指数、菌斑指数、牙周探诊深度、龈沟液量及龈沟液中碱性磷酸酶(ALP)、天门冬氨酸转氨酶(AST)水平。结果:研究组的修复成功率比对照组高(P<0.05)。研究组修复体的表面光滑率、边缘密合性、固定良好率及颜色匹配率均明显高于对照组(P<0.05)。两组治疗后牙龈指数、菌斑指数及牙周探诊深度均明显低于治疗前(P<0.05),龈沟液量及龈沟液中ALP、AST水平均明显低于治疗前(P<0.05),同时研究组治疗后牙龈指数、菌斑指数及牙周探诊深度均低于对照组(P<0.05),但两组治疗后龈沟液量及龈沟液中ALP、AST水平比较无差异(P>0.05)。结论:纤维桩、纳米复合树脂结合氧化锆烤瓷冠对根管治疗后后牙楔状缺损的修复成功率高,修复后美学效果佳,对牙周组织影响小。  相似文献   

15.
It has been suggested that existing frameworks for guiding management of invasive species in rural areas and protected areas are inadequate for dealing with invasions in urban settings. A framework for selecting appropriate goals for managing invasive species in urban areas was developed by Gaertner et al. (Landsc Urban Plan 151:1–9, 2016). This framework groups species into three management approaches (control priority, active engagement, and tolerance) depending on their real or perceived benefits and their potential to generate negative impacts. This study tests the practical application of the framework using the example of Cape Town. We assess the suitability of the framework to support decision-making for managing invasive species in urban ecosystems using a questionnaire-based survey of members of the public, and an e-mail-based survey and a workshop with invasion biology researchers and managers. Specifically, we (1) determine the differences in perceptions regarding the benefits and impacts of invasive species between the public, managers and researchers; (2) investigate how consistently managers and researchers group invasive species into the three management categories; and (3) identify, with the help of managers and researchers, issues linked to the framework and give suggestions to overcome the identified issues. We found no clear pattern in the perceptions of the public, managers and researchers regarding perceived benefits and negative impacts of invasive species. Instead, the answers were widely scattered among all groups for most of the species that were considered. However, using the framework leads to a higher consistency among managers in placing the species into management categories, compared to invasive species grouping without guidance of the framework. We conclude that decision-support frameworks can assist managers in placing invasive species into management categories. However, even more specific guidelines on the use of invasive species management frameworks in urban areas are needed.  相似文献   

16.
In this paper I examine exploratory behavior and learning in two groups of common marmosets (Callithrix jacchus jacchus), both living under laboratory conditions. The main aim of my studies was to compare behavior occurring in an experimental testing situation with home-cage behavior, and to assess conditions under which exploration is enhanced. One group of marmosets was tested individually in an experimental room away from a larger animal holding room, and a second group was observed in their own home cages, surrounded by other marmosets. Marmosets in both groups were given the opportunity to learn simple tasks, such as pressing a lever for food or jumping on to a wire grid to open a door and see a neighbouring marmoset, and were provided with sets of novel or familiar objects to encourage play and exploration. In the isolated experimental cage, marmosets which learnt a lever-pressing task showed higher general activity levels than controls; in the home cages the mere addition of novel objects resulted in enhancements in exploratory behavior (measured in terms of contacts with the objects). Although the activities associated with learning tended to decline over time, the novel objects remained a constant interest throughout the experiment. The results have implications for maintaining marmosets in captivity, especially in situations when they are housed separately.  相似文献   

17.
A land dispute following the "repossession" of territory in upstate New York by a group of Traditionalist Mohawk Indians is examined. Each side placed the dispute within the context of preexisting conflicts that served as "interpretive frameworks" for political actors. The process of change and manipulation of symbols that publicly represented these frameworks is traced. Research findings suggest that an answer for how symbols work in mobilizing groups to action can be found in the concurrence of change in symbols and meanings with continuity of interpretive framework.  相似文献   

18.
In this work, the experimental synthesized bipyridines 3,3'-Dinitro-2,2'-bipyridine (DNBPy), 3,3'-Dinitro-2,2'-bipyridine-1,1'-dioxide (DNBPyO), and (3-Nitro-2-pyridyl)(5-nitro-2-pyridyl) amine (NPyA), and a set of designed dipyridines that have similar frameworks but different linkages and substituents with NPyA were studied theoretically at the B3LYP/6-31G* level of density functional theory. The gas-phase heats of formation were predicted based on the isodesmic reactions and the condensed-phase heats of formation and heats of sublimation were estimated in the framework of the Politzer approach. The crystal densities have been computed from molecular packing. Results show that this method gives a good estimation of density in comparison with the available experimental data for DNBPy, DNBPyO, and NPyA. The predicted detonation velocities and pressures indicate that the performance of dipyridines linked with -O-, -NH-, or -CH(2)- bridges have not been improved compared with that of the directly linked dipyridines, but all derivatives have better detonation properties than DNBPy, DNBPyO, and NPyA because of the presence of more nitro groups. An analysis of the bond dissociation energies (BDEs) or the impact sensitivity (h (50)) suggests that introduction of different bridges but not substituents has little influence on thermal stability. The calculated h (50) may be more reliable than BDE for predicting stability. Four bridged bipyridines have quite good detonation performance and low sensitivity.  相似文献   

19.
Traumatic brain injury is a leading cause of disability and injury-related death. To enhance our ability to prevent such injuries, brain response can be studied using validated finite element (FE) models. In the current study, a high-resolution, anatomically accurate FE model was developed from the International Consortium for Brain Mapping brain atlas. Due to wide variation in published brain material parameters, optimal brain properties were identified using a technique called Latin hypercube sampling, which optimized material properties against three experimental cadaver tests to achieve ideal biomechanics. Additionally, falx pretension and thickness were varied in a lateral impact variation. The atlas-based brain model (ABM) was subjected to the boundary conditions from three high-rate experimental cadaver tests with different material parameter combinations. Local displacements, determined experimentally using neutral density targets, were compared to displacements predicted by the ABM at the same locations. Error between the observed and predicted displacements was quantified using CORrelation and Analysis (CORA), an objective signal rating method that evaluates the correlation of two curves. An average CORA score was computed for each variation and maximized to identify the optimal combination of parameters. The strongest relationships between CORA and material parameters were observed for the shear parameters. Using properties obtained through the described multiobjective optimization, the ABM was validated in three impact configurations and shows good agreement with experimental data. The final model developed in this study consists of optimized brain material properties and was validated in three cadaver impacts against local brain displacement data.  相似文献   

20.
《Journal of biomechanics》2014,47(16):3830-3836
The first aim of this study was to assess displacements and micro-strain induced on different grades of atrophic cortical and trabecular mandibular bone by axially loaded dental implants using finite element analysis (FEA). The second aim was to assess the micro-strain induced by different implant geometries and the levels of bone-to-implant contact (BIC) on the surrounding bone. Six mandibular bone segments demonstrating different grades of mandibular bone atrophy and various bone volume fractions (from 0.149 to 0.471) were imaged using a micro-CT device. The acquired bone STL models and implant (Brånemark, Straumann, Ankylos) were merged into a three-dimensional finite elements structure. The mean displacement value for all implants was 3.1±1.2 µm. Displacements were lower in the group with a strong BIC. The results indicated that the maximum strain values of cortical and cancellous bone increased with lower bone density. Strain distribution is the first and foremost dependent on the shape of bone and architecture of cancellous bone. The geometry of the implant, thread patterns, grade of bone atrophy and BIC all affect the displacement and micro-strain on the mandible bone. Preoperative finite element analysis could offer improved predictability in the long-term outlook of dental implant restorations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号