首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Background

For the development of specialized training protocols for robot assisted gait training, it is important to understand how the use of exoskeletons alters locomotor task demands, and how the nature and magnitude of these changes depend on training parameters. Therefore, the present study assessed the combined effects of gait speed and body weight support (BWS) on muscle activity, and compared these between treadmill walking and walking in the Lokomat exoskeleton.

Methods

Ten healthy participants walked on a treadmill and in the Lokomat, with varying levels of BWS (0% and 50% of the participants’ body weight) and gait speed (0.8, 1.8, and 2.8 km/h), while temporal step characteristics and muscle activity from Erector Spinae, Gluteus Medius, Vastus Lateralis, Biceps Femoris, Gastrocnemius Medialis, and Tibialis Anterior muscles were recorded.

Results

The temporal structure of the stepping pattern was altered when participants walked in the Lokomat or when BWS was provided (i.e. the relative duration of the double support phase was reduced, and the single support phase prolonged), but these differences normalized as gait speed increased. Alternations in muscle activity were characterized by complex interactions between walking conditions and training parameters: Differences between treadmill walking and walking in the exoskeleton were most prominent at low gait speeds, and speed effects were attenuated when BWS was provided.

Conclusion

Walking in the Lokomat exoskeleton without movement guidance alters the temporal step regulation and the neuromuscular control of walking, although the nature and magnitude of these effects depend on complex interactions with gait speed and BWS. If normative neuromuscular control of gait is targeted during training, it is recommended that very low speeds and high levels of BWS should be avoided when possible.  相似文献   

2.
Robotic-assistive exoskeletons can enable frequent repetitive movements without the presence of a full-time therapist; however, human-machine interaction and the capacity of powered exoskeletons to attenuate shoulder muscle and joint loading is poorly understood. This study aimed to quantify shoulder muscle and joint force during assisted activities of daily living using a powered robotic upper limb exoskeleton (ArmeoPower, Hocoma). Six healthy male subjects performed abduction, flexion, horizontal flexion, reaching and nose touching activities. These tasks were repeated under two conditions: (i) the exoskeleton compensating only for its own weight, and (ii) the exoskeleton providing full upper limb gravity compensation (i.e., weightlessness). Muscle EMG, joint kinematics and joint torques were simultaneously recorded, and shoulder muscle and joint forces calculated using personalized musculoskeletal models of each subject’s upper limb. The exoskeleton reduced peak joint torques, muscle forces and joint loading by up to 74.8% (0.113 Nm/kg), 88.8% (5.8%BW) and 68.4% (75.6%BW), respectively, with the degree of load attenuation strongly task dependent. The peak compressive, anterior and superior glenohumeral joint force during assisted nose touching was 36.4% (24.6%BW), 72.4% (13.1%BW) and 85.0% (17.2%BW) lower than that during unassisted nose touching, respectively. The present study showed that upper limb weight compensation using an assistive exoskeleton may increase glenohumeral joint stability, since deltoid muscle force, which is the primary contributor to superior glenohumeral joint shear, is attenuated; however, prominent exoskeleton interaction moments are required to position and control the upper limb in space, even under full gravity compensation conditions. The modeling framework and results may be useful in planning targeted upper limb robotic rehabilitation tasks.  相似文献   

3.
Evidence is emerging on how whole-body powered exoskeleton (EXO) use impacts users in basic occupational work scenarios, yet our understanding of how users learn to use this complex technology is limited. We explored how novice users adapted to using an EXO during gait. Six novices and five experienced users completed the study. Novices completed an initial training/familiarization gait session, followed by three subsequent gait sessions using the EXO, while experienced users completed one gait session with the EXO. Spatiotemporal gait measures, pelvis and lower limb joint kinematics, muscle activities, EXO torques, and human-EXO interaction forces were measured. Adaptations among novices were most pronounced in spatiotemporal gait measures, followed by joint kinematics, with smaller changes evident in muscle activity and EXO joint torques. Compared to the experienced users, novices exhibited a shorter step length and walked with significantly greater anterior pelvic tilt and less hip extension. Novices also used lower joint torques from the EXO at the hip and knee, and they had greater biceps femoris activity. Overall, our results may suggest that novices exhibited clear progress in learning, but they had not yet adopted motor strategies similar to those of experienced users after the three sessions. We suggest potential future directions to enhance motor adaptations to powered EXO in terms of both training protocols and human-EXO interfaces.  相似文献   

4.
Robot-aided gait therapy offers a promising approach towards improving gait function in individuals with neurological disorders such as stroke or spinal cord injury. However, incorporation of appropriate control strategies is essential for actively engaging the patient in the therapeutic process. Although several control algorithms (such as assist-as-needed and error augmentation) have been proposed to improve active patient participation, we hypothesize that the therapeutic benefits of these control algorithms can be greatly enhanced if combined with a motor learning task to facilitate neural reorganization and motor recovery. Here, we describe an active robotic training approach (patient-cooperative robotic gait training combined with a motor learning task) using the Lokomat and pilot-tested whether this approach can enhance active patient participation during training. Six neurologically intact adults and three chronic stroke survivors participated in this pilot feasibility study. Participants walked in a Lokomat while simultaneously performing a foot target-tracking task that necessitated greater hip and knee flexion during the swing phase of the gait. We computed the changes in tracking error as a measure of motor performance and changes in muscle activation as a measure of active subject participation. Repeated practice of the motor-learning task resulted in significant reductions in target-tracking error in all subjects. Muscle activation was also significantly higher during active robotic training compared to simply walking in the robot. The data from stroke participants also showed a trend similar to neurologically intact participants. These findings provide a proof-of-concept demonstration that combining robotic gait training with a motor learning task enhances active participation.  相似文献   

5.
Abstract

Purpose/aim of the study: An increase of hip abductor muscle strength contributes to the increase in gait speed. It is known that the rate of force development (RFD), an indicator of muscle strength, is increased by the combined use of low-intensity neuromuscular electrical stimulation (NMES) to the glutaeus medius (GM) and low-load resistance training (RT). However, it is unclear whether low-intensity neuromuscular electrical stimulation of the glutaeus medius during walking also increases the rate of force development. The aim of this study was to clarify whether NMES to the GM during gait modulates the RFD of the hip abductor muscles in healthy adults.

Materials and methods: Twenty-two healthy adults randomly received both gait with sub-motor threshold NMES and gait with sham NMES conditions. The RFD was assessed at pre- and post-intervention. A two-way repeated measures analysis of variance was used to analyse the effects of time and intervention.

Results: Gait with sub-motor threshold NMES condition significantly increased the RFD in shorter time interval (0–50 and 0–100?ms) compared to gait with sham NMES condition.

Conclusions: These findings suggest that the adding low-intensity NMES of the GM to gait is effective in increasing the RFD of the hip abductor muscles.  相似文献   

6.
The use of body weight support (BWS) systems during locomotor retraining has become routine in clinical settings. BWS alters load receptor feedback, however, and may alter the biomechanical role of the ankle plantarflexors, influencing gait. The purpose of this study was to characterize the biomechanical adaptations that occur as a result of a change in limb load (controlled indirectly through BWS) and gait speed during treadmill locomotion. Fifteen unimpaired participants underwent gait analysis with surface electromyography while walking on an instrumented dual-belt treadmill at seven different speeds (ranging from 0.4 to 1.6 m/s) and three BWS conditions (ranging from 0% to 40% BWS). While walking, spatiotemporal measures, anterior/posterior ground reaction forces, and ankle kinetics and muscle activity were measured and compared between conditions. At slower gait speeds, propulsive forces and ankle kinetics were unaffected by changing BWS; however, at gait speeds ≥approximately 0.8 m/s, an increase in BWS yielded reduced propulsive forces and diminished ankle plantarflexor moments and powers. Muscle activity remained unaltered by changing BWS across all gait speeds. The use of BWS could provide the advantage of faster walking speeds with the same push-off forces as required of a slower speed. While the use of BWS at slower speeds does not appear to detrimentally affect gait, it may be important to reduce BWS as participants progress with training, to encourage maximal push-off forces. The reduction in plantarflexor kinetics at higher speeds suggests that the use of BWS in higher functioning individuals may impair the ability to relearn walking.  相似文献   

7.
Robotic lower limb exoskeletons hold significant potential for gait assistance and rehabilitation; however, we have a limited understanding of how people adapt to walking with robotic devices. The purpose of this study was to test the hypothesis that people reduce net muscle moments about their joints when robotic assistance is provided. This reduction in muscle moment results in a total joint moment (muscle plus exoskeleton) that is the same as the moment without the robotic assistance despite potential differences in joint angles. To test this hypothesis, eight healthy subjects trained with the robotic hip exoskeleton while walking on a force-measuring treadmill. The exoskeleton provided hip flexion assistance from approximately 33% to 53% of the gait cycle. We calculated the root mean squared difference (RMSD) between the average of data from the last 15 min of the powered condition and the unpowered condition. After completing three 30-min training sessions, the hip exoskeleton provided 27% of the total peak hip flexion moment during gait. Despite this substantial contribution from the exoskeleton, subjects walked with a total hip moment pattern (muscle plus exoskeleton) that was almost identical and more similar to the unpowered condition than the hip angle pattern (hip moment RMSD 0.027, angle RMSD 0.134, p<0.001). The angle and moment RMSD were not different for the knee and ankle joints. These findings support the concept that people adopt walking patterns with similar joint moment patterns despite differences in hip joint angles for a given walking speed.  相似文献   

8.
This study investigated the lower extremity torque's active and passive features during the walk-to-run gait transition with continuously increased walking speed. Fourteen volunteers participated in the experiment. Kinematic and kinetic data were collected synchronously. Five strides leading up the gait transition were examined. Peaks of the passive (e.g., contact) and active (e.g., generalized muscle torques), along with net joint torque, and time to peak torques exhibited significant differences at the last stride before gait transition, compared to the first four strides, at the ankle, knee, and hip joints, respectively. Selected peak joint active and passive torques showed significant and opposite trends at critical events within a stride cycle: such ankle joint right after heel-contact, knee joint during weight acceptance, and both hip and knee joints right before toe-off. The magnitude and the corresponding time to active and passive peak torque changed in a nonlinear pattern before the transition from walk to run. The lower extremity segment-interaction during gait transition appeared to be an active reorganization exemplified by the interaction between the lower extremity's active and passive torque components.  相似文献   

9.
ObjectivesKinetic patterns of the lower extremity joints have been shown to be influenced by modification of the location of the center of pressure (CoP) of the foot. The accepted theory is that a shifted location of the CoP alters the distance between the ground reaction force and the center of the joint, thereby modifying torques during gait. Various footwear designs have been reported to significantly alter the magnitude of sagittal joint torques during gait. However, the relationship between the CoP and the kinetic patterns in the sagittal plane has not been examined. The aim of this study was to evaluate the association between the sagittal location of the CoP and gait patterns during gait in healthy men.MethodsA foot-worn biomechanical device which allows controlled manipulation of the CoP location was utilized. Fourteen healthy men underwent successive gait analysis with the device set to convey three different sagittal locations of the CoP: neutral, anterior offset and posterior offset.ResultsCoP translation in the sagittal plane (i.e., from posterior to anterior) significantly related with an ankle dorsiflexion torque and a knee extension torque shift throughout the stance phase. Likewise, an anterior translation of the CoP significantly reduced the extension torque at the hip during pre-swing.ConclusionsThe study results confirm a direct correlation between sagittal offset of the CoP and the magnitude of joint torques throughout the lower extremity.  相似文献   

10.
Muscle activities of the lower limb during level and uphill running   总被引:2,自引:1,他引:1  
This study aimed to compare the muscle activities of the lower limb during overground level running (LR) and uphill running (UR) by using a musculoskeletal model. Six male distance runners ran at three running speeds (slow: 3.3 m/s; medium: 4.2 m/s; and high: 5.0 m/s) on a level runway and a slope of 9.1% grade in which force platforms were mounted. A musculoskeletal leg model and optimization were used to estimate the muscle activation and muscle torque from the joint torque of the lower limb calculated by the inverse dynamics approach. At high speed, the activation and muscle torque of the muscle groups surrounding the hip joints, such as the hamstrings and iliopsoas, during the recovery phase were significantly greater during UR than during LR. At all the running speeds, the knee extension torque by the vasti during the support phase was significantly smaller during UR. Further, the hip flexion and knee extension torques by the rectus femoris during UR were significantly greater than those during LR at all the speeds; this would play a role in compensating for the decrease in the knee extension torque by the vasti and in maintaining the trunk in a forward-leaning position. These results revealed that the activation and muscle torque of the hip extensors and flexors were augmented during UR at the high speed.  相似文献   

11.
Repetitive task training is an effective form of rehabilitation for people suffering from debilitating injuries of stroke. We present the design and working concept of a robotic gait trainer (RGT), an ankle rehabilitation device for assisting stroke patients during gait. Structurally based on a tripod mechanism, the device is a parallel robot that incorporates two pneumatically powered, double-acting, compliant, spring over muscle actuators as actuation links which move the ankle in dorsiflex ion/plantarflexion and inversion/eversion. A unique feature in the tripod design is that the human anatomy is part of the robot, the first fixed link being the patient's leg. The kinematics and workspace of the tripod device have been analyzed determining its range of motion. Experimental gait data from an able-bodied person wearing the working RGT prototype are presented.  相似文献   

12.
Robotic locomotor training devices have gained popularity in recent years, yet little has been reported regarding contact forces experienced by the subject performing automated locomotor training, particularly in animal models of neurological injury. The purpose of this study was to develop a means for acquiring contact forces between a robotic device and a rodent model of spinal cord injury through instrumentation of a robotic gait training device (the rat stepper) with miniature force/torque sensors. Sensors were placed at each interface between the robot arm and animal's hindlimb and underneath the stepping surface of both hindpaws (four sensors total). Twenty four female, Sprague-Dawley rats received mid-thoracic spinal cord transections as neonates and were included in the study. Of these 24 animals, training began for 18 animals at 21 days of age and continued for four weeks at five min/day, five days/week. The remaining six animals were untrained. Animal-robot contact forces were acquired for trained animals weekly and untrained animals every two weeks while stepping in the robotic device with both 60 and 90% of their body weight supported (BWS). Animals that received training significantly increased the number of weight supported steps over the four week training period. Analysis of raw contact forces revealed significant increases in forward swing and ground reaction forces during this time, and multiple aspects of animal-robot contact forces were significantly correlated with weight bearing stepping. However, when contact forces were normalized to animal body weight, these increasing trends were no longer present. Comparison of trained and untrained animals revealed significant differences in normalized ground reaction forces (both horizontal and vertical) and normalized forward swing force. Finally, both forward swing and ground reaction forces were significantly reduced at 90% BWS when compared to the 60% condition. These results suggest that measurement of animal-robot contact forces using the instrumented rat stepper can provide a sensitive and reliable measure of hindlimb locomotor strength and control of flexor and extensor muscle activity in neurologically impaired animals. Additionally, these measures may be useful as a means to quantify training intensity or dose-related functional outcomes of automated training.  相似文献   

13.
The aim of this study was to explore the electromyographic, kinetic and kinematic patterns during a partially restricted sit-to-stand task in subjects with and without Parkinson’s disease (PD). If the trunk is partially restricted, different behavior of torques and muscle activities could be found and it can serve as a reference of the deterioration in the motor performance of subjects with PD. Fifteen subjects participated in this study and electromyography (EMG) activity of the tibialis anterior (TA), soleus (SO), vastus medialis oblique (VMO), biceps femoris (BF) and erector spinae (ES) were recorded and biomechanical variables were calculated during four phases of the movement. Subjects with PD showed more flexion at the ankle, knee and hip joints and increased knee and hip joint torques in comparison to healthy subjects in the final position. However, these joint torques can be explained by the differences in kinematic data. Also, the hip, knee and ankle joint torques were not different in the acceleration phase of movement. The use of a partially restricted sit-to-stand task in PD subjects with moderate involvement leads to the generation of joint torques similar to healthy subjects. This may have important implications for rehabilitation training in PD subjects.  相似文献   

14.
Hip loading affects the development of hip osteoarthritis, bone remodelling and osseointegration of implants. In this study, we analyzed the effect of subject-specific modelling of hip geometry and hip joint centre (HJC) location on the quantification of hip joint moments, muscle moments and hip contact forces during gait, using musculoskeletal modelling, inverse dynamic analysis and static optimization. For 10 subjects, hip joint moments, muscle moments and hip loading in terms of magnitude and orientation were quantified using three different model types, each including a different amount of subject-specific detail: (1) a generic scaled musculoskeletal model, (2) a generic scaled musculoskeletal model with subject-specific hip geometry (femoral anteversion, neck-length and neck-shaft angle) and (3) a generic scaled musculoskeletal model with subject-specific hip geometry including HJC location. Subject-specific geometry and HJC location were derived from CT. Significant differences were found between the three model types in HJC location, hip flexion–extension moment and inclination angle of the total contact force in the frontal plane. No model agreement was found between the three model types for the calculation of contact forces in terms of magnitude and orientations, and muscle moments. Therefore, we suggest that personalized models with individualized hip joint geometry and HJC location should be used for the quantification of hip loading. For biomechanical analyses aiming to understand modified hip joint loading, and planning hip surgery in patients with osteoarthritis, the amount of subject-specific detail, related to bone geometry and joint centre location in the musculoskeletal models used, needs to be considered.  相似文献   

15.
Hip loading affects bone remodeling and implant fixation. In this study, we have analyzed the effect of subject-specific modeling of hip geometry on muscle activation patterns and hip contact forces during gait, using musculoskeletal modeling, inverse dynamic analysis and static optimization. We first used sensitivity analysis to analyze the effect of isolated changes in femoral neck-length (NL) and neck-shaft angle (NSA) on calculated muscle activations and hip contact force during the stance phase of gait. A deformable generic musculoskeletal model was adjusted incrementally to adopt a physiological range of NL and NSA. In a second similar analysis, we adjusted hip geometry to the measurements from digitized radiographs of 20 subjects with primary hip osteoarthrosis. Finally, we studied the effect of hip abductor weakness on muscle activation patterns and hip contact force. This analysis showed that differences in NL (41-74 mm) and NSA (113-140 degrees ) affect the muscle activation of the hip abductors during stance phase and hence hip contact force by up to three times body weight. In conclusion, the results from both the sensitivity and subject-specific analysis showed that at the moment of peak contact force, altered NSA has only a minor effect on the loading configuration of the hip. Increased NL, however, results in an increase of the three hip contact-force components and a reduced vertical loading. The results of these analyses are essential to understand modified hip joint loading, and for planning hip surgery for patients with osteoarthrosis.  相似文献   

16.
摘要 目的:探讨达芬奇机器人与腹腔镜手术治疗胰腺癌的近期疗效比较及对血清C-反应蛋白(CRP)、降钙素原(PCT)及肿瘤标志物的影响。方法:选择2019年1月至2020年1月在我院接受治疗的61例胰腺癌患者,根据手术方法分为机器人组(n=26)和腹腔镜组(n=35)。腹腔镜组给予腹腔镜手术治疗,机器人组给予达芬奇机器人辅助治疗。比较两组围术期情况、CRP 、PCT、糖类抗原19-9(CA19-9)、糖类抗原125(CA125)、术后恢复情况及并发症发生情况。结果:机器人组禁食时间及排气时间显著低于腹腔镜组,差异显著(P<0.05);治疗前,两组血清CA19-9、CA125水平无明显差异;治疗后,两组血清CA19-9、CA125水平治疗后较治疗前均显著下降差异显著(P<0.05);两组治疗后血清CA19-9、CA125水平比较无显著差异(P>0.05);治疗前,两组CRP、PCT水平无明显差异;治疗后,两组CRP、PCT明显升高,且机器人组低于腹腔镜组差异显著(P<0.05);机器人组和腹腔镜组术后下床活动时间、拔尿管时间、术后住院时间比较无显著差异;机器人组术后重症监护时间显著低于腹腔镜组,差异显著(P<0.05);两组患者治疗期间并发症总发生率分别为4.44%、6.67%,无显著差异(P>0.05)。结论:达芬奇机器人辅助能够显著提高胰腺癌手术质量,且对血清CRP 、PCT的影响较小,且对肿瘤标志物的影响与腹腔镜手术较为接近,为患者提供机器人微创治疗是未来临床的必然发展趋势。  相似文献   

17.
Simulating realistic musculoskeletal dynamics is critical to understanding neural control of muscle activity evoked in sensorimotor feedback responses that have inherent neural transmission delays. Thus, the initial mechanical response of muscles to perturbations in the absence of any change in muscle activity determines which corrective neural responses are required to stabilize body posture. Muscle short-range stiffness, a history-dependent property of muscle that causes a rapid and transient rise in muscle force upon stretch, likely affects musculoskeletal dynamics in the initial mechanical response to perturbations. Here we identified the contributions of short-range stiffness to joint torques and angles in the initial mechanical response to support surface translations using dynamic simulation. We developed a dynamic model of muscle short-range stiffness to augment a Hill-type muscle model. Our simulations show that short-range stiffness can provide stability against external perturbations during the neuromechanical response delay. Assuming constant muscle activation during the initial mechanical response, including muscle short-range stiffness was necessary to account for the rapid rise in experimental sagittal plane knee and hip joint torques that occurs simultaneously with very small changes in joint angles and reduced root mean square errors between simulated and experimental torques by 56% and 47%, respectively. Moreover, forward simulations lacking short-range stiffness produced unreasonably large joint angle changes during the initial response. Using muscle models accounting for short-range stiffness along with other aspects of history-dependent muscle dynamics may be important to advance our ability to simulate inherently unstable human movements based on principles of neural control and biomechanics.  相似文献   

18.
Lower extremity muscle strength training is a focus of rehabilitation following total hip arthroplasty (THA). Strength of the hip abductor muscle group is a predictor of overall function following THA. The purpose of this study was to investigate the effects of hip abductor strengthening following rehabilitation on joint contact forces (JCFs) in the lower extremity and low back during a high demand step down task. Five THA patients performed lower extremity maximum isometric strength tests and a stair descent task. Patient-specific musculoskeletal models were created in OpenSim and maximum isometric strength parameters were scaled to reproduce measured pre-operative joint torques. A pre-operative forward dynamic simulation of each patient performing the stair descent was constructed using their corresponding patient-specific model to predict JCFs at the ankle, knee, hip, and low back. The hip abductor muscles were strengthened with clinically supported increases (0–30%) above pre-operative values in a probabilistic framework to predict the effects on peak JCFs (99% confidence bounds). Simulated hip abductor strengthening resulted in lower peak JCFs relative to pre-operative for all five patients at the hip (18.9–23.8 ± 16.5%) and knee (20.5–23.8 ± 11.2%). Four of the five patients had reductions at the ankle (7.1–8.5 ± 11.3%) and low back (3.5–7.0 ± 5.3%) with one patient demonstrating no change. The reduction in JCF at the hip joint and at joints other than the hip with hip abductor strengthening demonstrates the dynamic and mechanical interdependencies of the knee, hip and spine that can be targeted in early THA rehabilitation to improve overall patient function.  相似文献   

19.
A variety of musculoskeletal models are applied in different modelling environments for estimating muscle forces during gait. Influence of different modelling assumptions and approaches on model outputs are still not fully understood, while direct comparisons of standard approaches have been rarely undertaken. This study seeks to compare joint kinematics, joint kinetics and estimated muscle forces of two standard approaches offered in two different modelling environments (AnyBody, OpenSim). It is hypothesised that distinctive differences exist for individual muscles, while summing up synergists show general agreement. Experimental data of 10 healthy participants (28 ± 5 years, 1.72 ± 0.08 m, 69 ± 12 kg) was used for a standard static optimisation muscle force estimation routine in AnyBody and OpenSim while using two gait-specific musculoskeletal models. Statistical parameter mapping paired t-test was used to compare joint angle, moment and muscle force waveforms in Matlab. Results showed differences especially in sagittal ankle and hip angles as well as sagittal knee moments. Differences were also found for some of the muscles, especially of the triceps surae group and the biceps femoris short head, which occur as a result of different anthropometric and anatomical definitions (mass and inertia of segments, muscle properties) and scaling procedures (static vs. dynamic). Understanding these differences and their cause is crucial to operate such modelling environments in a clinical setting. Future research should focus on alternatives to classical generic musculoskeletal models (e.g. implementation of functional calibration tasks), while using experimental data reflecting normal and pathological gait to gain a better understanding of variations and divergent behaviour between approaches.  相似文献   

20.
Femoroacetabular impingement syndrome (FAIS) consists of abnormal hip joint morphology and pain during activities of daily living. Abnormal gait mechanics and potentially abnormal muscle forces within FAI patients leads to articular cartilage damage. Therefore, there is a necessity to understand the effects of FAI on hip joint muscle forces during gait and the link between muscle forces, patient reported outcomes (PRO) and articular cartilage health. The purposes of this study were to assess: (1) hip muscle forces between FAI patients and healthy controls and (2) the associations between hip muscle forces with PRO and cartilage composition (T/T2 mapping) within FAI patients. Musculoskeletal simulations were used to estimate peak muscle forces during the stance phase of gait in 24 FAI patients and 24 healthy controls. Compared to controls, FAI patients ambulated with lower vasti (30% body-weight, p = 0.01) and higher sartorius (4.0% body-weight, p < 0.01) forces. Within FAI patients, lower peak gluteus medius, gluteus minimus, sartorius and iliopsoas forces were associated with worse hip joint pain and function (R = 0.43–0.70, p = 0–0.04), while lower muscle forces were associated with increased T and T2 values (i.e. altered cartilage composition) within the hip joint cartilage (R = −0.44 to −0.58, p = 0.006–0.05). Although FAI patients demonstrate abnormal muscle forces, it is unknown whether or not these altered muscle force patterns are associated with pain avoidance or weak musculature. Further investigation is required in order to better understand the effects of FAI on hip joint muscle forces and the associations with hip joint cartilage degeneration.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号