首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Ketamine-anesthetized Sprague-Dawley rats were exposed to far-field 700-MHz continuous-wave radiofrequency radiation (RFR) in both E and H orientations. Irradiation was conducted at whole-body average specific absorption rates (SARs) of 9.2 and 13.0 W/kg (E and H, respectively) that resulted in approximately equivalent colonic specific heating rates (SHRs). Exposures were performed to repeatedly increase colonic temperature by 1 degree C (38.5 to 39.5 degrees C). Tympanic, tail, left and right subcutaneous (toward and away from RFR source), and colonic temperatures, arterial blood pressure, and respiratory rate were continuously recorded. In spite of equivalent colonic SHRs and the reduced E-orientation average SAR, the right subcutaneous, tympanic, and tail SARs, SHRs and absolute temperature increases were significantly greater in E than in H orientation. The cooling rate at all monitoring sites was also significantly greater in E than in H orientation. Heart rate and mean arterial blood pressure significantly increased during irradiation; however, changes between orientations were not different. Respiratory rate significantly increased during irradiation in H, but not in E orientation. These results indicate that during resonant frequency irradiation, differences occur in the pattern of heat deposition between E- and H-orientation exposure. When compared with previous investigations performed at supraresonant frequencies, the lower level of cardiovascular change in this study was probably related to the lower periphery-to-core thermal gradient.  相似文献   

2.
The purpose of this study was to determine the effects of exposure orientation relative to electric and magnetic fields (E and H fields) on the thermal, cardiovascular, and respiratory changes in ketamine-anesthetized rats exposed to far-field, continuous-wave, 9.3-GHz radiofrequency radiation (RFR). Irradiation (specific absorption rate = 12.5 W/kg in both orientations; power levels of 79 and 59 mW/cm2 in E and H orientations, respectively) was conducted to produce 1 degree C colonic temperature changes (38.5 to 39.5 degrees C). During experimentation, arterial blood pressure and respiratory rate, colonic (Tc) tympanic (Tt) left and right subcutaneous (Tsl & Tsr) (sides toward and away from RFR source), and tail temperatures (Tta) were continuously recorded. The Tsr change during E-orientation exposure was considerably less than the Tc change; the Tt and Tsr (H-orientation) changes approximated the Tc increase; and the Tsl and Tta changes (both orientations) were considerably greater than the Tc increase. The Tt and Tsl increases were virtually equal under the two exposure conditions; however, the Tsr increase was significantly greater during H-orientation irradiation, and the Tta increase was significantly greater during E-orientation exposure. Heart rate and mean arterial pressure increased significantly during irradiation; however the cardiovascular responses were not affected by exposure orientation. The latter findings at 9.3 GHz contrast with the marked cardiovascular response differences between E- and H-orientation exposure noted during previous studies at 0.7 to 2.45 GHz.  相似文献   

3.
Summary Ketamine-anesthetized Sprague-Dawley rats were exposed in H orientation to far-field 9.3-GHz continuous-wave (CW) and pulsed (2 µs, 500 pps) radiofrequency radiation (RFR) at average power densities of 30 and 60 mW/cm2 (whole-body average specific absorption rates of 9.3 and 18.6 W/kg, respectively). Irradiation was conducted to cyclicly increase colonic temperature from 38.5 to 39.5° C. Colonic, tympanic, and subcutaneous temperatures, ECG, blood pressure, and respiratory rate were continuously recorded during experimentation. At both power densities, the subcutaneous and tympanic temperature increases significantly exceeded the colonic temperature increase. At both exposure levels, heart rate increased significantly during irradiation and returned to baseline when exposure was discontinued. Blood pressure and respiratory rate did not significantly change during irradiation. There were no significant differences between the effects of CW and pulsed RFR exposure. The levels of subcutaneous heating and heart rate change were greater, and the times required to achieve and to recover from a 1° C colonic temperature increase were longer than in previous studies conducted at 2.8 GHz. Results of these studies indicate that the carrier frequency used during irradiation markedly affects the pattern of heat distribution and the physiological responses of RF-irradiated animals.  相似文献   

4.
Ketamine-anesthetized Sprague-Dawley rats were exposed to far-field 1200-MHz continuous wave radiofrequency radiation in both E and H orientations (long axis of animal parallel to electric or magnetic field, respectively). Power densities were used that resulted in equivalent whole-body specific absorption rates of approximately 8 W/kg in both orientations (20 mW/cm2 for E and 45 mW/cm2 for H). Exposure was conducted to repeatedly increase colonic temperature from 38.5 to 39.5 degrees C in both orientations in the same animal. Irradiation in E orientation resulted in greater colonic, tympanic, left subcutaneous (side toward antenna), and tail heating. The results indicated a more uniform distribution of heat than that which occurred in previous experiments of 2450-MHz irradiation in E and H orientation. A lack of significant differences in blood pressure and heart rate responses between exposures in the two orientations in this study suggest that greater peripheral heating, as was seen in the earlier study of 2450 MHz, is necessary for these differences to occur.  相似文献   

5.
Relatively large thermal gradients may exist during exposure of an animal to microwaves (MWs), particularly at high frequencies. Differences in thermal gradients within the body may lead to noticeable differences in the magnitude of cardiovascular changes resulting from MW exposure. This study compares the thermal distribution and cardiovascular effects of exposure to a single MW frequency with effects of simultaneous exposure to two frequencies. Ketamine-anesthetized male Sprague-Dawley rats (n = 58) were exposed individually to one of three conditions: 1-GHz, 10-GHz, or combined 1- and 10-GHz MWs at an equivalent whole-body specific absorption rate of 12 W/kg. The continuous-wave irradiation was conducted under far-field conditions with animals in E orientation (left lateral exposure, long axis parallel to the electric field) or in H orientation (left lateral exposure, long axis perpendicular to the electric field). Irradiation was started when colonic temperature was 37.5 degrees C and was continued until lethal temperatures were attained. Colonic, tympanic, left and right subcutaneous, and tail temperatures, and arterial blood pressure, heart rate, and respiratory rate were continuously recorded. In both E and H orientations, survival time (i.e., time from colonic temperature of 37.5 degrees C until death) was lowest in animals exposed at 1-GHz, intermediate in those exposed at 1- and 10-GHz combined, and greatest in the 10-GHz group (most differences statistically significant). At all sites (with the exception of right subcutaneous), temperature values in the 1- and 10-GHz combined group were between those of the single-frequency exposure groups in both E and H orientations. During irradiation, arterial blood pressure initially increased and then decreased until death. Heart rate increased throughout the exposure period. The general, overall patterns of these changes were similar in all groups. The results indicate that no unusual physiological responses occur during multi-frequency MW exposure, when compared with results of single-frequency exposure. Bioelectromagnetics 21:159-166, 2000. Published 2000 Wiley-Liss, Inc.  相似文献   

6.
Cardiovascular and thermal responses in rats during 94 GHz irradiation   总被引:1,自引:0,他引:1  
We investigated the thermal distribution and cardiovascular effects produced by sustained exposure of rats to 94 GHz radio-frequency electromagnetic radiation (RFR). Sixteen ketamine-anesthetized Sprague-Dawley rats were exposed individually at a power density of 75 mW/cm2 under far-field conditions in E orientation. Irradiation began when colonic temperature was 37 degrees C and continued until death. Large, immediate increases in subcutaneous temperature on the irradiated side were accompanied by more moderate, delayed increases in colonic temperature. These body-temperature responses were similar to previous results obtained during 35 GHz RFR exposure. During irradiation, arterial blood pressure initially increased and then precipitously decreased until death. The heart rate increased throughout the exposure period. When comparing the results of these 94 GHz exposures with those in previous studies of lower RFR frequencies, it appears that the patterns of heart-rate and blood-pressure changes that occur before death are similar. We conclude that exposure to 94 GHz RFR produces extreme peripheral heating without similar levels of core heating and that this pattern of heat deposition is sufficient to produce circulatory failure and subsequent death.  相似文献   

7.
Summary To compare the effects of ketamine anesthesia and mild restraint on microwave-induced thermal and cardiovascular changes, sixteen Fischer 344 rats were irradiated in two states:1) unanesthetized, restrained, and2) ketamine-anesthetized (150 mg/kg, I.M.). Individual animals were exposed in H orientation to far-field continuous-wave 2.8-GHz microwaves. Irradiation was conducted at a power density of 60 mW/cm2 (whole-body average specific absorption rate of 14.4 W/kg) to cyclicly increase colonic temperature from 38.5 to 39.5° C. Colonic and subcutaneous temperatures, aortic blood pressure, and heart rate were continuously monitored. The time required for colonic temperature to increase 1° C was significantly longer in the anesthetized state; however, the time to return to baseline was similar under both conditions. Heart rate and blood pressure significantly increased during irradiation in the unanesthetized state, but remained virtually unchanged in the anesthetized state. The subcutaneous temperature increase during exposure was significantly greater in the anesthetized state. The differences in responses of anesthetized and mildly restrained animals should be considered when conducting experiments on thermoregulatory responses to microwave irradiation.  相似文献   

8.
The present study was performed to determine if any heart rate or blood pressure changes occur during intermittent exposure to radiofrequency radiation (RFR), and to determine if parasympathetic blockade due to atropine has any effect on these changes or on thermal responses. Anesthetized rats were exposed to 2.8 GHz pulsed RFR at an average power level of 60 mW/cm2 (average specific absorption rate, 14 W/kg). During an initial exposure period to raise colonic temperature to 39.5 degrees C, heart rate decreased significantly. This thermal bradycardia is similar to that reported by other investigators during environmental heat exposure. Intermittent exposure to radiation, which was designed to result in 1 degree C colonic temperature changes, did not significantly affect heart rate or mean arterial blood pressure, before or after atropine administration. The time courses of these 1 degree C temperature changes were not altered significantly by atropine. Following administration of atropine, the thermal bradycardia during the initial heating period was still evident. Thus, factors other than vagal activity are responsible for the phenomenon. It is possible that the bradycardia is a consequence of a general reduction in metabolism, which occurs also during environmental heat exposure.  相似文献   

9.
Anesthetized rats were exposed to 5.6-GHz continuous wave radiofrequency radiation at an average power density of 60 mW/cm2 (average specific absorption rate 12 W/kg). Exposure was performed to raise colonic temperature from 38.5 to 39.5 degrees C. Following acute administration of chlorpromazine, body temperature exhibited a faster return to baseline temperature when exposure was discontinued. When exposure was initiated at 38.5 degrees C and continued until lethal temperatures resulted, chlorpromazine-treated animals exhibited significantly shorter survival times than saline-treated animals. Thus, although chlorpromazine enhanced thermo-regulatory efficiency at colonic temperatures below 39.5 degrees C, the drug caused increased susceptibility to terminal radiofrequency radiation exposure. The present results, when compared to previous studies of irradiation at 2.8 GHz, indicate that the effects of chlorpromazine on thermal responses to RFR during intermittent and terminal exposure are similar at both 2.8 and 5.6 GHz.  相似文献   

10.
The purpose of this study was to determine whether chronic, low-level exposure of mammary-tumor-prone mice to 2450 MHz radiofrequency radiation (RFR) promotes an earlier onset (decreased latency), a greater total incidence, or a faster growth rate of mammary tumors. One hundred C3H/HeJ mice were exposed in circularly polarized waveguides (CWG) for 18 months (20 h/day, 7 days/wk) to continuous-wave, 2450 MHz RFR at a whole body average specific absorption rate (SAR) of 0.3 W/kg; 100 mice were sham exposed. Before exposure, SARs were determined calorimetrically; during experimentation, SARs were monitored by differential power measurement. All animals were visually inspected twice daily and were removed from the CWG cages for a weekly inspection, palpation, and weighing. From the time of detection, tumor size was measured weekly. Animals that died spontaneously, became moribund, or were killed after 18 months of exposure were completely necropsied; tissues were fixed and subjected to histopathological evaluations. Results showed no significant difference in weight profiles between sham-irradiated and irradiated mice. Concerning mammary carcinomas, there was no significant difference between groups with respect to palpated tumor incidence (sham = 52%; irradiated = 44%), latency to tumor onset (sham = 62.3 ± 1.2 wk; irradiated = 64.0 ± 1.6 wk), and rate of tumor growth. In general, histopathological examination revealed no significant differences in numbers of malignant, metastatic, or benign neoplasms between the two groups; a significantly greater incidence of alveolar-bronchiolar adenoma in the sham-irradiated mice was the only exception. In addition, survival analysis showed no significant difference in cumulative percent survival between sham and irradiated animals. Thus, results indicate that under the conditions of this study, long-term, low-level exposure of mammary-tumor-prone mice to 2450 MHz RFR did not affect mammary tumor incidence, latency to tumor onset, tumor growth rate, or animal longevity when compared with sham-irradiated controls. Bioelectromagnetics 19:20–31, 1998. © 1998 Wiley-Liss, Inc.  相似文献   

11.
Radiofrequency radiation (RFR) causes heating, which can lead to detrimental biological effects. To characterize the effects of RFR exposure on body temperature in relation to animal size and pregnancy, a series of short‐term toxicity studies was conducted in a unique RFR exposure system. Young and old B6C3F1 mice and young, old, and pregnant Harlan Sprague‐Dawley rats were exposed to Global System for Mobile Communication (GSM) or Code Division Multiple Access (CDMA) RFR (rats = 900 MHz, mice = 1,900 MHz) at specific absorption rates (SARs) up to 12 W/kg for approximately 9 h a day for 5 days. In general, fewer and less severe increases in body temperature were observed in young than in older rats. SAR‐dependent increases in subcutaneous body temperatures were observed at exposures ≥6 W/kg in both modulations. Exposures of ≥10 W/kg GSM or CDMA RFR induced excessive increases in body temperature, leading to mortality. There was also a significant increase in the number of resorptions in pregnant rats at 12 W/kg GSM RFR. In mice, only sporadic increases in body temperature were observed regardless of sex or age when exposed to GSM or CDMA RFR up to 12 W/kg. These results identified SARs at which measurable RFR‐mediated thermal effects occur, and were used in the selection of exposures for subsequent toxicology and carcinogenicity studies. Bioelectromagnetics. 39:190–199, 2018. © 2018 The Authors. Bioelectromagnetics Published by Wiley Periodicals, Inc.  相似文献   

12.
These experiments were designed to investigate the effects of sub-resonant microwave (MW) exposure (350 MHz, E orientation, average power density 38 mW/cm2, average whole-body specific absorption rate 13.2 W/kg) on selected physiological parameters. The increase in peripheral body temperature during 350 MHz exposure was greater than that in earlier experiments performed at 700 MHz (resonance). Heart rate and mean arterial blood pressure were significantly elevated during a 1 °C increase in colonic temperature due to 350 MHz exposure; respiratory rate showed no significant change. The results are consistent with other investigators' reports comparing sub-resonance exposures with those at resonance and above. Bioelectromagnetics 18:335–338, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

13.
Effects of intermittent exposure to 5.6-GHz radiofrequency radiation (RFR) on heart rate, blood pressure, and respiratory rate were examined in anesthetized rats. During exposure to 60 mW/cm2 which resulted in a 1 degree C change in colonic temperature, heart rate increased; the values returned to control levels after exposure was discontinued. No changes in mean arterial blood pressure or in respiratory rate were observed. Exposure to 30 mW/cm2 caused no significant changes in heart rate, blood pressure, or respiratory rate. The data indicate that heart rate changes during exposure to 5.6-GHz RFR are related to the average power density applied, and thus to the rate of change in temperature, and not simply to the absolute change in temperature.  相似文献   

14.
1. Whole-body exposure of animals to radiofrequency radiation (RFR) can cause an increase in body temperature. 2. Responses to heating, whether due to RFR or to more conventional means, include changes in heart rate and blood pressure. 3. Although cardiovascular responses to various types of heating are similar, differences in the magnitude of changes may result from different thermal gradients within the body. 4. This review compares the effects of RFR and conventional environmental heating on heart rate and blood pressure.  相似文献   

15.
16.
This study investigated the effects of intermittent exposure (15 min on, 15 min off for 1, 2, 3, or 4 h, at a specific absorption rate of 2 W/kg) to enhanced data rates for global system for mobile communication evolution-modulated radiofrequency radiation (RFR) at 900- and 1,800-MHz frequencies on the viability of the Hepatocarcinoma cells (Hep G2). Hep G2 cell proliferation was measured by a colorimetric assay based on the cleavage of the tetrazolium salt WST-1 by mitochondrial dehydrogenases in viable cells. Cell injury was evaluated by analyzing the levels of lactate dehydrogenase (LDH) and glucose released from lysed cells into the culture medium. Morphological observation of the nuclei was carried out by 4′,6-diamidino-2-phenylindole (DAPI) staining using fluorescence microscopy. In addition, TUNEL assay was performed to confirm apoptotic cell death. It was observed that cell viability, correlated with the LDH and glucose levels, changed according to the frequency and duration of RFR exposure. Four-hour exposure produced more pronounced effects than the other exposure durations. 1,800-MHz RFR had a larger impact on cell viability and Hep G2 injury than the RFR at 900 MHz. Morphological observations also supported the biochemical results indicating that most of the cells showed irregular nuclei pattern determined by using the DAPI staining, as well as TUNEL assay which shows DNA damage especially in the cells after 4 h of exposure to 1,800-MHz RFR. Our results indicate that the applications of 900- and 1,800-MHz (2 W/kg) RFR cause to decrease in the proliferation of the Hep G2 cells after 4 h of exposure. Further studies will be conducted on other frequency bands of RFR and longer duration of exposure.  相似文献   

17.
The effects of CO2 (100 ppm) bathing were investigated. It was found that the chest blood flow, chest sweat rate and tympanic temperature were significantly greater during the immersion in CO2 bathing than in freshwater bathing (P<0.05). Thus, CO2 bathing at 100 ppm could produce cutaneous vasodilatation in the immersed skin, affecting thermoregulation.  相似文献   

18.
Alekseev  S. I.  Ziskin  M. C.  Fesenko  E. E. 《Biophysics》2011,56(3):525-528
The possibility of using thermocouples for artifact-free measurement of skin temperature during millimeter-wave exposure was studied. The distributions of the specific absorption rate (SAR) in the human skin were calculated for different orientations of the thermocouple relative to the E vector of the electromagnetic field. It was shown that, at the parallel orientation of the thermocouple relative to the E-field, SAR significantly increased about the tip of the thermocouple, which could lead to overheating. At the perpendicular orientation of the thermocouple, SAR distortions were insignificant. The data obtained confirm that the skin temperature can be measured with a thermocouple during exposure, provided that the thermocouple is perpendicular to the E-field. For accurate determination of SAR from the initial rate of temperature rise, the kinetics measured with the thermocouple must be fitted with the bio-heat transfer equation.  相似文献   

19.
This study was undertaken to determine the effects of 2,450-MHz microwave irradiation on thermoregulation, metabolism, and cardiovascular function of rats. Young adult male animals (430 g) were exposed for 30 min to 2,450-MHz microwaves in a cavity at absorbed dose rates of 0, 4.5, 6.5, or 11.1 mW/G. For animals of the size used in this study, these dose rates represent absorption of energy at the rate of 27.7, 40.1, and 68.2 cal/min, respectively. For a period of 5 h following exposure, measurements were made of colonic temperature, skin temperature, oxygen consumption, carbon dioxide production, respiratory quotient, and heart rate. Rats that received 27.7 cal/min for 30 min exhibited an initial transient increase in colonic and skin temperatures but no alterations in other functions. The group irradiated at 40.1 cal/min had greater elevations in colonic and skin temperatures immediately after exposure, followed by overcompensation and lower than normal colonic temperatures for about 3 h. The metabolic rate was depressed in this group for 3 h. Bradycardia developed within 20 min after exposure and persisted for about 3 h. The group of rats that received 68.2 cal/min for 30 min had responses similar to those of the 40.1 cal/min group, but the changes were more severe and lasted longer. In addition, a number of transient abnormalities were noted in the ECG tracings of rats that had received the highest dose, including irregular rhythms and incomplete heart block. The physiological changes observed in this study can be attributed to the heating induced by irradiation.  相似文献   

20.
Effects of various physical and chemical treatments of Colorado potato beetle [Leptinotarsa decemlineata (Coleoptera: Chrysomelidae)] eggs on parasitization and development of the egg parasitoid Edovum puttleri (Hymenoptera: Eulophidae) were investigated. UV irradiation did not affect host acceptance but reduced host suitability for UV exposure times 90 min. Susceptibility of host eggs to UV irradiation varied with host age; eggs were most vulnerable to damage from irradiation at 12, 18, and 24 h post-oviposition. The rate of parasitization also was influenced by host age. Percent parasitization was greatest in freshly laid eggs and 24–30 h old eggs. Seventy-seven percent of host eggs frozen at –20 °C (5 min) were parasitized by E. puttleri, but extended exposure of eggs to –20 °C reduced both acceptance and suitability. Host eggs that had been washed with hexane (removal of kairomone and sticky layer) also were parasitized. After 5 min of washing, application of kairomone significantly increased the rate of parasitism (from 74.7% to 88.2%), but with longer periods of washing, kairomone application had no significant effect on percent parasitism. Thus, the sticky material(s) coating the egg did not appear to be essential for parasitization to occur. Our results provide effective methods and times for treating Colorado potato beetle eggs to maximize parasitization and development of E. puttleri.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号