首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Previous studies have shown that, in the stress-shielded patellar tendon, the mechanical properties of the tendon were dramatically reduced and TGF-beta was over-expressed in tendon fibroblasts. In the present study, therefore, we tested two supportive hypotheses using 40 rabbits: One was that an application of TGF-beta1 might significantly increase the tensile strength and the tangent modulus of the stress-shielded patellar tendon. The other one was that an administration of anti-TGF-beta1 antibody might significantly reduce the mechanical properties of the stress-shielded patellar tendon. In the results, an application of 4-ng TGF-beta1 significantly increased the tangent modulus of the stress-shielded patellar tendon at 3 weeks (p = 0.019), compared with the sham treatment. Concerning the tensile strength, the 4-ng TGF-beta1 application increased the average value, but a statistical significance was not reached. An application of 50-microg anti-TGF-beta1 antibody significantly reduced the tangent modulus and the tensile strength of the stress-shielded patellar tendon at 3 weeks (p = 0.0068 and p = 0.0355), compared with the sham treatment. Because the stress-shielding treatment used in this study dramatically reduces the tangent modulus and the tensile strength of the patellar tendon, the present study suggested that an administration of TGF-beta1 weakly but significantly inhibited the reduction of the mechanical properties of the stress-shielded patellar tendon, and that inactivation of TGF-beta1 with its antibody significantly enhanced the reduction of the mechanical properties that occurs in the stress-shielded patellar tendon. These results suggested that TGF-beta1 plays an important role in remodeling of the stress-shielded patellar tendon.  相似文献   

2.
Mechanical properties of collagen fascicles from the rabbit patellar tendon   总被引:1,自引:0,他引:1  
Tensile and viscoelastic properties of collagen fascicles of approximately 300 microns in diameter, which were obtained from rabbit patellar tendons, were studied using a newly designed micro-tensile tester. Their cross-sectional areas were determined with a video dimension analyzer combined with a CCD camera and a low magnification microscope. There were no statistically significant differences in tensile properties among the fascicles obtained from six medial-to-lateral locations of the patellar tendon. Tangent modulus, tensile strength, and strain at failure of the fascicles determined at about 1.5 percent/s strain rate were 216 +/- 68 MPa, 17.2 +/- 4.1 MPa, and 10.9 +/- 1.6 percent (mean +/- S.D.), respectively. These properties were much different from those of bulk patellar tendons; for example, the tensile strength and strain at failure of these fascicles were 42 percent and 179 percent of those of bulk tendons, respectively. Tangent modulus and tensile strength of collagen fascicles determined at 1 percent/s strain rate were 35 percent larger than those at 0.01 percent/s. The strain at failure was independent of strain rate. Relaxation tests showed that the reduction of stress was approximately 25 percent at 300 seconds. These stress relaxation behavior and strain rate effects of collagen fascicles differed greatly from those of bulk tendons. The differences in tensile and viscoelastic properties between fascicles and bulk tendons may be attributable to ground substances, mechanical interaction between fascicles, and the difference of crimp structure of collagen fibrils.  相似文献   

3.
Effects of cyclic stress on the mechanical properties of collagen fascicles were studied by in vitro tissue culture experiments. Collagen fascicles (approximately 300 microns in diameter) obtained from the rabbit patellar tendon were applied cyclic load at 4 Hz for one hour per day during culture period for one or two weeks, and then their mechanical properties were determined using a micro-tensile tester. There was a statistically significant correlation between tensile strength and applied peak stress in the range of 0 to 5 MPa, and the relation was expressed by a quadratic function. The maximum strength (19.4 MPa) was obtained at the applied peak stress of 1.8 MPa. The tensile strength of fascicles were within a range of control values, if they were cultured under peak stresses between 1.1 and 2.6 MPa. Similar results were also observed in the tangent modulus, which was maintained at control level under applied peak stresses between 0.9 and 2.8 MPa. The stress of 0.9 to 1.1 MPa is equivalent to approximately 40% of the in vivo peak stress which is developed in the intact rabbit patellar tendon by running, whereas that of 2.6 to 2.8 MPa corresponds to approximately 120% of the in vivo peak stress. Therefore, the fascicles cultured under applied peak stresses of lower than 40% and higher than 120% of the in vivo peak stress do not keep the original strength and modulus. These results indicate that the mechanical properties of cultured collagen fascicles strongly depend upon the magnitude of the stress applied during culture, which are similar to our previous results observed in stress-shielded and overstressed patellar tendons in vivo.  相似文献   

4.
We previously found that interleukin (IL)-1beta is over-expressed in the fibroblasts of the stress-shielded patellar tendon using a stress-shielding model [Uchida, H., Tohyama, H., Nagashima, K., Ohba, Y., Matsumoto, H., Toyama, Y., Yasuda, K., 2005. Stress deprivation simultaneously induces over-expression of interleukin-1beta, tumor necrosis factor-alpha, and transforming growth factor-beta in fibroblasts and mechanical deterioration of the tissue in the patellar tendon. Journal of Biomechanics 38(4), 791-798.]. Therefore, IL-1beta may play a role in tendon deterioration in response to stress deprivation. This study was conducted to clarify the effects of local administration of interleukin-1 receptor antagonist (IL-1ra) on the mechanical properties of the stress-shielded patellar tendon as well as the tendon fascicles harvested from it. Twenty-six mature rabbits were equally divided into Groups IL-1ra and PBS after the right patellar tendon underwent the stress-shielding treatment, which completely released the patellar tendon from tension by stretching the flexible wire installed between the patella and the tibial tubercle. In Group IL-1ra, IL-1ra was injected between the patellar tendon and the infra-patellar fat pad. In Group PBS, phosphate-buffered saline was injected in the same manner as IL-1ra. All rabbits were evaluated at 3 weeks after the stress-shielding procedure. The tangent modulus and the tensile strength of the patellar tendons were significantly greater in Group IL-1ra than in Group PBS, while there was no significant difference in the strain at failure between Groups IL-1ra and PBS. Concerning the mechanical properties of the fascicles harvested from the patellar tendon, however, we could not detect any significant differences in the tangent modulus, tensile strength, or strain at failure between Groups IL-1ra and PBS. The present study suggested that IL-1 plays an important role in the deterioration of the mechanical properties of the patellar tendon in response to stress shielding and that IL-1 does not affect the fascicles themselves.  相似文献   

5.
Growth-related changes in the mechanical properties of collagen fascicles (approximately 300 microm in diameter) were studied using patellar tendons obtained from skeletally immature 1 and 2 months old and matured 6 months old rabbits. Tensile properties were determined using a specially designed micro-tensile tester. In each age group, there were no significant differences in the properties among cross-sectional locations in the tendon. Tangent modulus and tensile strength significantly increased with age; the rates of their increases between 1 and 2 months were higher than those between 2 and 6 months. The tangent modulus and tensile strength were positively correlated with the body weight of animals. However, growth-related changes in the mechanical properties were different between collagen fascicles and bulk patellar tendons, which may be attributable to such non-collagenous components as ground substances and also to mechanical interactions between collagen fascicles.  相似文献   

6.
The objectives of this study were to determine the longitudinal and transverse material properties of the human medial collateral ligament (MCL) and to evaluate the ability of three existing constitutive models to describe the material behavior of MCL. Uniaxial test specimens were punched from ten human cadaveric MCLs and tensile tested along and transverse to the collagen fiber direction. Using load and optical strain analysis information, the tangent modulus, tensile strength and ultimate strain were determined. The material coefficients for each constitutive model were determined using nonlinear regression. All specimens failed within the substance of the tissue. Specimens tested along the collagen fiber direction exhibited the typical nonlinear behavior reported for ligaments. This behavior was absent from the stress-strain curves of the transverse specimens. The average tensile strength, ultimate strain, and tangent modulus for the longitudinal specimens was 38.6 +/- 4.8 MPa, 17.1 +/- 1.5 percent, and 332.2 +/- 58.3 MPa, respectively. The average tensile strength, ultimate strain, and tangent modulus for the transverse specimens was 1.7 +/- 0.5 MPa, 11.7 +/- 0.9 percent, and 11.0 +/- 3.6 MPa, respectively. All three constitutive models described the longitudinal behavior of the ligament equally well. However, the ability of the models to describe the transverse behavior of the ligament varied.  相似文献   

7.
To test the hypothesis that stress deprivation induces over-expression of cytokines in the patellar tendon, 40 rats were divided into the following two groups. In the stress-shielded group, we slackened the patellar tendon in the right knee by drawing the patella toward the tibial tubercle with flexible wires. In the control group, we performed a sham operation on the right knee. Animals were killed at 2 or 6 weeks for immunohistological evaluation and biomechanical examination. For IL-1beta, TNF-alpha and TGF-beta, the ratio of positively stained specimens to total specimens was significantly higher in the stress-shielded tendons than in the control tendons. The elastic modulus of the stress-shielded tendon was significantly lower than that of the control tendon, while the cross-sectional area of the stress-shielded tendon was significantly greater than that of the control tendon. Therefore, the present study indicated that stress shielding induced the over-expression of IL-1beta, TNF-alpha and TGF-beta in patellar tendon fibroblasts with mechanical deterioration of the tendon. Regarding clinical relevance, the present study suggests a possible application of an anti-IL-1beta or anti-TNF-alpha strategy for reducing the mechanical deterioration of tendons and ligaments in response to stress deprivation, although this study did not directly show that over-expression of IL-1beta or TNF-alpha in response to stress deprivation was the causation of mechanical deterioration of tendons.  相似文献   

8.
Central third of patellar tendon (PT) is used as an autograft for anterior cruciate ligament (ACL) reconstruction. Previous studies investigated temporal changes in material properties of healing tissues in PT after resection of the central third. However, no study has been performed on effects of stress shielding (SS) and restressing (RS) on the properties of healing tissues. The present study hypothesised that SS adversely affects the mechanical integrity of healing tissues, which is recovered by subsequent RS. An entire rectangular defect was created in the central third of rabbit PT. Operated PTs were subjected to either SS or no stress shielding (NSS). A subgroup of stress-shielded PTs was followed by the resumption of normal loading, namely RS. Tensile properties of tissues regenerated in the defect and residual tendons were evaluated. Regenerated tissues of SS for 3 weeks resulted in significantly lower strength than NSS, which was recovered to NSS level by 3 weeks of RS. Strength of residual tissues in RS reversed SS effects, leading to the strength at NSS level after 12 weeks. However, tangent modulus of residual tissues in RS was still significantly lower than that of NSS at 12 weeks. Therefore, SS induces detrimental effects on the mechanical integrity of healing PTs, and the response to RS was different between regenerate and residual tissues, the latter of which took longer period to reach NSS level.  相似文献   

9.
In-vitro tissue culture experiments were performed to study the effects of static stress on the mechanical properties of collagen fascicles obtained from the rabbit patellar tendon. After collagen fascicles having the diameter of approximately 300 microm were cultured for 1 and 2 wk under static stress between 0 and 3 MPa, their mechanical properties and crimp morphology were determined using a micro-tensile tester and a light microscope, respectively. The tensile strength and tangent modulus of the fascicles were significantly decreased by culture under no load compared to control fascicles. A statistically significant correlation, which was described by a quadratic curve, was observed between applied stress and tensile strength. The maximum tensile strength (16.7 MPa) was obtained at the applied stress of 1.2 MPa; the strength was within a range of control values. There was a similar correlation between applied stress and tangent modulus, and the modulus was maintained at control level under 1.3 MPa stress. The stress of 1.2 to 1.3 MPa is equivalent to approximately 50 percent of the peak stress developed in the intact rabbit patellar tendon by running. Strain at failure of cultured collagen fascicles was negatively correlated with applied stress, and that at 1.2 to 1.3 MPa stress was almost the same as the control value. Crimp morphology in the fascicles cultured under about 1.2 MPa stress was similar to that in control fascicles. These results indicate that cultured collagen fascicles change the mechanical properties and structure in response to static tensile stress. In addition, their mechanical properties and structure are maintained at control level if the static stress of 50 percent of in-vivo peak stress is applied.  相似文献   

10.
Effects of the overstressing induced by the harvest of grafts from the patellar tendon on the mechanical properties and morphometry of remaining tendon were studied using a rabbit model. The width of the patellar tendon was reduced by one-fourth or one-half equally removing the medial and lateral portions; by this surgery, the cross-sectional area was decreased by 25 or 50 percent from the original area. After all the rabbits were allowed unrestricted activities in cages for 3 to 12 weeks, their patellar tendons were harvested for mechanical and histological studies. The one-fourth removal induced no significant changes in the mechanical properties, but significantly increased the cross-sectional area. In the case of one-half removal, tensile strength and tangent modulus did not change in some tendons, although the cross-sectional area increased significantly. In the other central half tendons, mechanical strength decreased markedly, while the cross-sectional area increased; hypercellular areas and breakage of collagen bundles were observed in these tendons. These results indicate that the patellar tendon has an ability of functionally adapting to overstressing by changing the cross-sectional area, while keeping the mechanical properties unchanged, if the extent of overstressing is less than 30 percent.  相似文献   

11.
The effects of frequency or duration of cyclic stress on the mechanical properties of collagen fascicles were studied by means of in vitro tissue culture experiments. Collagen fascicles of approximately 300 microm in diameter were obtained from rabbit patellar tendons. During culture, cyclic stress having the peak stress of approximately 2 MPa was applied to the fascicles at 1 Hz for 1 hour/day (1 Hz-1 h group), at 1 Hz for 4 hours/day (1 Hz-4 h group), or at 4 Hz for 1 hour/day (4 Hz-1 h group). The frequency of 4 Hz and the duration of 1 hour/day are considered to be similar to those of the in vivo stress applied to fascicles in the intact rabbit patellar tendon. After culture for 1 or 2 weeks, the mechanical properties of the fascicles were determined using a microtensile tester, and were compared to the properties of non-cultured, fresh fascicles (control group) and the fascicles cultured under no load condition (non-loaded group). The tangent modulus and tensile strength of fascicles in the 4 Hz-1 h group were similar to those in the control group; however, the fascicles of the 1 Hz-1 h and 1 Hz-4 h groups had significantly lower values than those of the control group. There was no significant difference in the tensile strength between the 1 Hz-1 h and non-loaded groups, although the strength in the 1 Hz-4 h group was significantly higher than that of the non-loaded group. It was concluded that the frequency and duration of cyclic stress significantly affect the mechanical properties of cultured collagen fascicles. If we apply cyclic stress having the frequency and duration which are experienced in vivo, the biomechanical properties are maintained at control, normal level. Lower frequencies or less cycles of applied force induce adverse effects.  相似文献   

12.
In order to provide insight into the mechanical response of the collagen fascicle structures in tendon, a series of constant strain rate and constant displacement, stress relaxation mechanical tests were performed on sequentially sectioned human patellar tendon specimens (protocol 1) and specimens with both small (approximately 1 mm2) and large (approximately 20 mm2) cross-sectional areas (protocol 2). These data described the stress relaxation and constant strain rate tensile responses as a function of cross-sectional area and water content. The experimental data suggested that small portions of tendon exhibit a higher tensile modulus, a slower rate of relaxation and a lower amount of relaxation in comparison to larger specimens from the same location in the same tendon. The decrease in relaxation response and the increase in tensile modulus with decreasing cross-sectional area was nonlinear. These data suggest that there may be structures other than the subfascicle, such as the epitenon and other connective tissue components, which influence the tensile and stress relaxation responses in tendon.  相似文献   

13.
A tissue-cultured tendon matrix infiltrated with cultured fibroblasts can be regarded as an ideal tissue-engineered tendon model. To clarify the role of TGF-beta in a tissue-cultured tendon matrix during ex vivo cellular infiltration, the present ex vivo study was conducted to test the following hypothesis that antibody neutralization of TGF-beta enhances weakening of the collagen fascicles of the patellar tendon matrix in response to ex vivo fibroblast infiltration. In skeletally mature female rabbits, fibroblasts were isolated from the right patellar tendons using an explant culture technique, and the left patellar tendons underwent multiple freeze/thaw treatment with liquid nitrogen to obtain an acellular tendon matrix. Each acellular tendon was placed in a collagen gel containing cultured fibroblasts and then incubated with or without anti-TGF-beta1 antibody for 6 weeks. We found that antibody neutralization of TGF-beta enhanced the decrease in the tensile strength and tensile modulus of the collagen fascicles of the patellar tendon matrix in response to ex vivo fibroblast infiltration. The present study indicates a possibility that TGF-beta may have a role in suppressing the material deterioration of the fascicles in the tendon during ex vivo cellular infiltration.  相似文献   

14.
We studied birefringence as an indicator of collagen fiber orientation in the diaphysis of the equine third metacarpal bone. We had previously shown that tissue from the lateral cortex of this bone is stronger monotonically, but less fatigue resistant, than tissue from the medial and dorsal regions. To learn whether collagen fiber orientation might play a role in this regional specialization, we tested three hypotheses using the same specimens: (1) collagen fiber orientation is regionally dependent; (2) remodeling changes collagen fiber orientation; (3) longitudinal collagen fibers correlate positively with modulus and monotonic bending strength and negatively with flexural fatigue life. Beams (N=36) cut parallel to the long axes of six pairs of bones had been tested to determine elastic modulus (N=36), and fatigue life (N=24) or monotonic strength (N=12) in four-point bending. Subsequently, histologic cross-sections were prepared, and porosity, active remodeling and past remodeling were quantified. Birefringence was measured as an indicator of transverse collagen orientation using plane-polarized light (PPL), and again using circularly polarized light (CPL). The CPL measurement was less variable than the PPL measurement. Both birefringence measures indicated that collagen was more longitudinally oriented in the lateral cortex than in the other two cortices. Longitudinally disposed collagen correlated with greater modulus and monotonic strength, but did not correlate with fatigue life. Remodeling was associated with more transverse collagen. Neither measure of birefringence was significantly correlated with porosity. It was concluded that, in the equine cannon bone, longitudinal collagen fiber orientation is regionally variable, contributes to increased modulus and strength but not fatigue life, and is reduced by osteonal remodeling.  相似文献   

15.
Mechanical properties and collagen structure of excisional wounds left open are compared with wounds closed by clips. In both wound models, collagen fiber diameter increases with time post-wounding and is related to tensile strength. Clipped wounds show a higher ultimate tensile strength and tangent modulus compared with open wounds. In clipped wounds, newly deposited collagen appears as a biaxially oriented network as observed in normal skin. In open wounds a delay in the organization of the collagen network is observed and parallel wavy-shaped ribbons of collagen fibers are deposited. At long term, the high extensibility observed in open wounds may be due to the sliding of ribbons of collagen fibers past each other.  相似文献   

16.
In a detailed study mechanical properties of tendons, muscles, nerves, blood-vessels and skin of just slaughtered pigs have been investigated in nearly stationary stress tests. Tensile tests have produced tensile strength, ultimate stress and their appropriate strains, Young's modulus and the work up to fatigue of samples. In hysteresis tests the deformation work has been determined as a function of numbers of stress cycles. The hysteresis decrease with the number of stress cycles and approaches asymptotically to cero. By preconditioning of tendons, nerves and blood-vessels to steady state significant differences of strain at tensile strength and of Young's modulus have been established. Moreover for nerves the tests have revealed significant deviations of tensile strength. Bruise tests have been carried out with muscle tissue. For the described setup the limit force can be specified, at which pathological changes appear. Subsequently conducted histological investigations have demonstrated this. In dynamical bruise tests there appeared no pathological changes in muscle tissue in spite of higher transmitted energy.  相似文献   

17.
Li LP  Herzog W 《Biorheology》2004,41(3-4):181-194
The relative importance of fluid-dependent and fluid-independent transient mechanical behavior in articular cartilage was examined for tensile and unconfined compression testing using a fibril reinforced model. The collagen matrix of articular cartilage was modeled as viscoelastic using a quasi-linear viscoelastic formulation with strain-dependent elastic modulus, while the proteoglycan matrix was considered as linearly elastic. The collagen viscoelastic properties were obtained by fitting experimental data from a tensile test. These properties were used to investigate unconfined compression testing, and the sensitivity of the properties was also explored. It was predicted that the stress relaxation observed in tensile tests was not caused by fluid pressurization at the macroscopic level. A multi-step tensile stress relaxation test could be approximated using a hereditary integral in which the elastic fibrillar modulus was taken to be a linear function of the fibrillar strain. Applying the same formulation to the radial fibers in unconfined compression, stress relaxation could not be simulated if fluid pressurization were absent. Collagen viscoelasticity was found to slightly weaken fluid pressurization in unconfined compression, and this effect was relatively more significant at moderate strain rates. Therefore, collagen viscoelasticity appears to play an import role in articular cartilage in tensile testing, while fluid pressurization dominates the transient mechanical behavior in compression. Collagen viscoelasticity plays a minor role in the mechanical response of cartilage in unconfined compression if significant fluid flow is present.  相似文献   

18.
The linear organization of collagen fibers in tendons results in optimal stiffness and strength at low strains under tensile load. However, this organization makes repairing ruptured or lacerated tendons extremely difficult. Current suturing techniques to join split ends of tendons, while providing sufficient mechanical strength to prevent gapping, are inadequate to carry normal loads. Immobilization protocols necessary to restore tendon congruity result in scar formation at the repair site and peripheral adhesions that limit excursion. These problems are reviewed to emphasize the need for novel approaches to tendon repair, one of which is the development of biomimetic tendons. The objective of the empirical work described here was to produce biologically-based, biocompatible tendon replacements with appropriate mechanical properties to enable immediate mobilization following surgical repair. Nor-dihydroguaiaretic acid (NDGA), a di-catechol from creosote bush, caused a dose dependent increase in the material properties of reconstituted collagen fibers, achieving a 100-fold increase in strength and stiffness over untreated fibers. The maximum tensile strength of the optimized NDGA treated fibers averaged 90 MPa; the elastic modulus of these fibers averaged 580 MPa. These properties were independent of strain rates ranging from 0.60 to 600 mm/min. Fatigue tests established that neither strength nor stiffness were affected after 80 k cycles at 5% strain. Treated fibers were not cytotoxic to tendon fibroblasts. Fibroblasts attached and proliferated on NDGA treated collagen normally. NDGA-fibers did not elicit a foreign body response nor did they stimulate an immune reaction during six weeks in vivo. The fibers survived 6 weeks with little evidence of fragmentation or degradation. The polymerization scheme described here produces a fiber-reinforced NDGA-polymer with mechanical properties approaching an elastic solid. The strength, stiffness and fatigue properties of the NDGA-treated fibers are comparable to those of tendon. These fibers are biocompatible with tendon fibroblasts and elicit little rejection or antigenic response in vivo. These results indicate that NDGA polymerization may provide a viable approach for producing collagenous materials that can be used to bridge gaps in ruptured or lacerated tendons. The tendon-like properties of the NDGA-fiber would allow early mobilization after surgical repair. We predict that timely loading of parted tendons joined by this novel biomaterial will enhance mechanically driven production of neo-tendon by the colonizing fibroblasts and result in superior repair and rapid return to normal properties.  相似文献   

19.
Force-elongation responses of the human abdominal wall in the linea alba region were determined by tensile tests in which the linea alba was seen to exhibit a nonlinear elastic, anisotropic behavior as is frequently observed in soft biological tissues. In addition, the geometry of the abdominal wall was determined, based on MRI data. The geometry can be specified by principal radii of curvature in longitudinal of approximately 470 mm and in the transverse direction of about 200 mm. The determined radii agree with values found in other studies. Mechanical stresses, deformations and abdominal pressures for load cases above 6% elongation can be related using Laplace's formula and our constitutive and geometrical findings. Results from uni- and biaxial tensile tests can thus be compared using this model. Calculations confirm that abdominal pressures of approximately 20 kPa correspond to related biaxial forces of about 3.4N/mm in the transverse and 1.5 N/mm in the longitudinal direction. Young's moduli can be calculated with respect to the uniaxial as well as the biaxial loading. At these physiological loadings, a compliance ratio of about 2:1 between the longitudinal and transversal directions is found. Young's moduli of about 50 kPa occur in transversal direction and of about 20 kPa in longitudinal direction at transverse and longitudinal strains both in the order of 6%. These findings coincide with results from other investigations in which the properties of the abdominal wall have been examined.  相似文献   

20.
Characterization of the elastic properties of a tendon could enhance the diagnosis and treatment of tendon injuries. The purpose of this study was to examine the correlation between the shear elastic modulus on the patellar tendon captured from a Supersonic Shear Imaging (SSI) and the tangent traction modulus computed from a Material testing system (MTS) on 8 fresh patellar pig tendons (Experiment I). Test–retest reliability of the shear elastic modulus captured from the SSI was established in Experiment II on 22 patellar tendons of 11 healthy human subjects using the SSI. Spearman Correlation coefficients for the shear elastic modulus and tangent traction modulus ranged from 0.82 to 1.00 (all p<0.05) on the 8 tendons. The intra and inter-operator reliabilities were 0.98 (95% CI: 0.93–0.99) and 0.97 (95% CI: 0.93–0.98) respectively. The results from this study demonstrate that the shear elastic modulus of the patellar tendon measured by the SSI is related to the tangent traction modulus quantified by the MTS. The SSI shows good intra and inter-operator repeatability. Therefore, the present study shows that SSI can be used to assess elastic properties of a tendon.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号