首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Different tendons are designed to withstand different mechanical loads in their individual environments. Variable physiologic loading ranges and correspondingly different injury thresholds lead to tendon heterogeneity. Also, tendon heterogeneity is evident when examining how different tendons regulate their response to changes in mechanical loading (over- and under-loading). The response of tendons to changes in mechanical loading plays an important role in the induction and progression of tendinosis which is tendon degeneration without inflammation. Tendon overuse injury is likely related to abnormal mechanical loading that deviates from normal mechanical loading in magnitude, frequency, duration and/or direction. Mechanical loading that results in tendon overuse injury can initiate a repair process but, after failed initial repair, non-resolving chronic attempted repair appears to lead to a "smoldering" fibrogenesis. Contributions of regulatory components, including minor components in the "nerve-mast cell-myofibroblast axis", are key features in the development and progression of tendinosis. Hormonal and genetic factors may also influence risk for tendinosis. Further understanding of how tendinosis induction is related to mechanical use/overuse, how tendinosis progression is related to abnormal regulation of attempted repair, and how induction and/or progression are modulated by other risk factors may lead to interventions that mitigate risk and enhance functional repair.  相似文献   

2.
Achilles tendon injuries affect both athletes and the general population, and their incidence is rising. In particular, the Achilles tendon is subject to dynamic loading at or near failure loads during activity, and fatigue induced damage is likely a contributing factor to ultimate tendon failure. Unfortunately, little is known about how injured Achilles tendons respond mechanically and structurally to fatigue loading during healing. Knowledge of these properties remains critical to best evaluate tendon damage induction and the ability of the tendon to maintain mechanical properties with repeated loading. Thus, this study investigated the mechanical and structural changes in healing mouse Achilles tendons during fatigue loading. Twenty four mice received bilateral full thickness, partial width excisional injuries to their Achilles tendons (IACUC approved) and twelve tendons from six uninjured mice were used as controls. Tendons were fatigue loaded to assess mechanical and structural properties simultaneously after 0, 1, 3, and 6 weeks of healing using an integrated polarized light system. Results showed that the number of cycles to failure decreased dramatically (37-fold, p<0.005) due to injury, but increased throughout healing, ultimately recovering after 6 weeks. The tangent stiffness, hysteresis, and dynamic modulus did not improve with healing (p<0.005). Linear regression analysis was used to determine relationships between mechanical and structural properties. Of tendon structural properties, the apparent birefringence was able to best predict dynamic modulus (R2=0.88–0.92) throughout healing and fatigue life. This study reinforces the concept that fatigue loading is a sensitive metric to assess tendon healing and demonstrates potential structural metrics to predict mechanical properties.  相似文献   

3.
Several investigators have recently used fiberoptic cables to measure tendon forces in situ. The technique may be subject to significant error due to cable migration and differences in the loading rates used for calibration and those experienced during measurement. This in vitro study examined the impact of these potential sources of error on transducer accuracy. A fiberoptic cable was passed perpendicular to the fibers of four Achilles tendons in the mediolateral direction and each specimen was cyclically loaded to 1000 N. The influence of loading rate on transducer output was investigated by comparing results from tests conducted at 20, 200 and 1000 N/s. The effect of cable migration was examined by comparing the outputs obtained after displacing the cable one tendon width medially and laterally along its path in the tendon and then repeating the 200 N/s testing protocol. It was possible to obtain nonlinear specimen-specific relationships between the fiberoptic output and tendon force. Differences in loading rate resulted in root-mean-square (RMS) errors not larger than 17% maximum load. Hysteresis effects caused RMS errors smaller than 5% maximum load. Cable migration errors were less than 27%. The total RMS error due to the combined effects of loading rate difference and cable movement was less than 32%. Fiberoptic measurement of tendon force is attractive due to its low cost, easy implementation and comparable accuracy relative to other implantable force transducers. Although additional factors such as cable placement, edge artifacts due where the transducer exits the skin and non-uniform loading may also influence fiberoptic output, careful control of loading rate and transducer movement during calibration is imperative if maximum accuracy is to be achieved.  相似文献   

4.
《Journal of biomechanics》2014,47(16):3813-3819
Acoustoelastic (AE) ultrasound image analysis is a promising non-invasive approach that uses load-dependent echo intensity changes to characterize stiffness of tendinous tissue. The purpose of this study was to investigate whether AE can detect localized changes in tendon stiffness due to partial and full-thickness tendon tears. Ovine infraspinatus tendons with different levels of damage (Intact, 33%, 66% and full thickness cuts initiated on the articular and bursal sides) were cyclically loaded in a mechanical testing system while cine ultrasound images were recorded. The load-induced changes in echo intensity on the bursal and articular side of the tendon were determined. Consistent with AE theory, the undamaged tendons exhibited an increase in echo intensity with tendon loading, reflecting the strain-stiffening behavior of the tissue. In the intact condition, the articular region demonstrated a significantly greater increase in echo intensity during loading than the bursal region. Cuts initiated on the bursal side resulted in a progressive decrease in echo intensity of the adjacent tissue, likely reflecting the reduced load transmission through that region. However, image intensity information was less sensitive for identifying load transmission changes that result from partial thickness cuts initiated on the articular side. We conclude that AE approaches may be useful to quantitatively assess load-dependent changes in tendon stiffness, and that disruption of AE behavior may be indicative of substantial tendon damage.  相似文献   

5.
Measurements of in-vitro carpal kinematics of the wrist provide valuable biomechanical data. Tendon loading is often applied during cadaver experiments to simulate natural stabilizing joint compression in the wrist joint. The purpose of this study was to investigate the effect of tendon loading on carpal kinematics in-vitro.A cyclic movement was imposed on 7 cadaveric forearms while the carpal kinematics were acquired by a 4-dimensional rotational X-ray imaging system. The extensor- and flexor tendons were loaded with constant force springs of 50 N, respectively. The measurements were repeated without a load on the tendons. The effect of loading on the kinematics was tested statistically by using a linear mixed model.During flexion and extension, the proximal carpal bones were more extended with tendon loading. The lunate was on the average 2.0° (p=0.012) more extended. With tendon loading the distal carpal bones were more ulnary deviated at each angle of wrist motion. The capitate was on the average 2.4° (p=0.004) more ulnary deviated.During radioulnar deviation, the proximal carpal bones were more radially deviated with the lunate 0.7° more into radial deviation with tendon loading (p<0.001). Conversely, the bones of distal row were more flexed and supinated with the capitate 1.5° more into flexion (p=0.025) and 1.0° more into supination (p=0.011).In conclusion, the application of a constant load onto the flexor and extensor tendons in cadaver experiments has a small but statistically significant effect on the carpal kinematics during flexion–extension and radioulnar deviation.  相似文献   

6.
The aim of this project was to see whether the tendon would show creep during long-term dynamic loading (here referred to as dynamic creep). Pig tendons were loaded by a material-testing machine with a human Achilles tendon force profile (1.37 Hz, 3% strain, 1,600 cycles), which was obtained in an earlier in vivo experiment during running. All the pig tendons showed some dynamic creep during cyclic loading (between 0.23 +/- 0.15 and 0.42 +/- 0.21%, means +/- SD). The pig tendon data were used as an input of a model to predict dynamic creep in the human Achilles tendon during running of a marathon and to evaluate whether there might consequently be an influence on group Ia afferent-mediated length and velocity feedback from muscle spindles. The predicted dynamic creep in the Achilles tendon was considered to be too small to have a significant influence on the length and velocity feedback from soleus during running. In spite of the characteristic nonlinear viscoelastic behavior of tendons, our results demonstrate that these properties have a minor effect on the ability of tendons to act as predictable, stable, and elastic force transmitters during long-term cyclic loading.  相似文献   

7.
Factors influencing the output of an implantable force transducer   总被引:1,自引:0,他引:1  
The objective of this study was to evaluate the performance of the Arthroscopically Implantable Force Probe (AIFP; MicroStrain, Burlington VT) for measuring force in a patellar tendon graft. Transducer drift, reproducibility of output due to the number of loading cycles and device location, and sensitivity to the tendon cross-sectional area were investigated. The AIFP was initialized, and then implanted into five human patellar tendon grafts three times; twice within the same location and once in a different location. The tendons were cyclically loaded in uniaxial tension for 500 cycles in each insertion site. The AIFP was then removed from the tendon and the baseline output was remeasured. It was determined that transducer drift was negligible. The relationship between the tensile load applied to the graft and AIFP output was quadratic and specimen dependent. The cyclic load response of the tendon-AIFP interface demonstrated a 24.9% decrease over the first 20 loading cycles, and subsequent cycling yielded relatively reproducible output. The output of the transducer varied when it was removed from the tendon and then reimplanted in the same location (range 3.7-109. 4% error), as well as in the second location (range 1.5-202.8% error). No correlation was observed between the cross-sectional area of the tendon and transducer output. This study concludes that implantable force probes should be used with caution and calibrated without removing the transducer from the graft.  相似文献   

8.
Tendon tissue engineering approaches are challenged by a limited understanding of the role mechanical loading plays in normal tendon development. We propose that the increased loading that developing postnatal tendons experience with the onset of locomotor behavior impacts tendon formation. The objective of this study was to assess the onset of spontaneous weight-bearing locomotion in postnatal day (P) 1, 5, and 10 rats, and characterize the relationship between locomotion and the mechanical development of weight-bearing and non-weight-bearing tendons. Movement was video recorded and scored to determine non-weight-bearing, partial weight-bearing, and full weight-bearing locomotor behavior at P1, P5, and P10. Achilles tendons, as weight-bearing tendons, and tail tendons, as non-weight-bearing tendons, were mechanically evaluated. We observed a significant increase in locomotor behavior in P10 rats, compared to P1 and P5. We also found corresponding significant differences in the maximum force, stiffness, displacement at maximum force, and cross-sectional area in Achilles tendons, as a function of postnatal age. However, the maximum stress, strain at maximum stress, and elastic modulus remained constant. Tail tendons of P10 rats had significantly higher maximum force, maximum stress, elastic modulus, and stiffness compared to P5. Our results suggest that the onset of locomotor behavior may be providing the mechanical cues regulating postnatal tendon growth, and their mechanical development may proceed differently in weight-bearing and non-weight-bearing tendons. Further analysis of how this loading affects developing tendons in vivo may inform future engineering approaches aiming to apply such mechanical cues to regulate engineered tendon formation in vitro.  相似文献   

9.
Proteoglycans (PG) and their associated glycosaminoglycan (GAG) side chains are known to play a key role in the bearing of compressive loads in cartilage and other skeletal connective tissues. In tendons and connective tissues that are primarily loaded in tension, the influence of proteoglycans on mechanical behavior is debated due to conflicting experimental evidence that alternately supports or controverts a functional role of proteoglycans in bearing tensile load. In this study we sought to better reconcile these conflicting data by investigating the possibility that GAG content is differentially related to tensile tendon mechanics depending upon the anatomical subregion one considers. To test this hypothesis, we quantified the mechanical consequences of proteoglycan disruption within specific tendon anatomical subregions using an optical–mechanical measurement approach.Achilles tendons from adult mice were treated with chondroitinase ABC to obtain two groups consisting of native tendons and GAG-depleted tendons. All the tendons were mechanically tested and imaged with high-resolution digital video in order to optically quantify tendon strains. Tendon surface strains were locally analyzed in three main subregions: the central midsubstance, and the proximal and distal midsubstance near the muscle and bone insertions, respectively. Upon GAG digestion, the tendon midsubstance softened appreciably near the bone insertion, while elastic modulus in the central and proximal thirds was unchanged. Thus the contribution of PGs to tensile tendon mechanics is not straightforward and points to a heterogeneous and complex structure–function relationship in tendon. This study further highlights the importance of performing local strain analysis with regard to tensile tendon mechanics.  相似文献   

10.
Mechanobiology of tendon   总被引:9,自引:0,他引:9  
Tendons are able to respond to mechanical forces by altering their structure, composition, and mechanical properties--a process called tissue mechanical adaptation. The fact that mechanical adaptation is effected by cells in tendons is clearly understood; however, how cells sense mechanical forces and convert them into biochemical signals that ultimately lead to tendon adaptive physiological or pathological changes is not well understood. Mechanobiology is an interdisciplinary study that can enhance our understanding of mechanotransduction mechanisms at the tissue, cellular, and molecular levels. The purpose of this article is to provide an overview of tendon mechanobiology. The discussion begins with the mechanical forces acting on tendons in vivo, tendon structure and composition, and its mechanical properties. Then the tendon's response to exercise, disuse, and overuse are presented, followed by a discussion of tendon healing and the role of mechanical loading and fibroblast contraction in tissue healing. Next, mechanobiological responses of tendon fibroblasts to repetitive mechanical loading conditions are presented, and major cellular mechanotransduction mechanisms are briefly reviewed. Finally, future research directions in tendon mechanobiology research are discussed.  相似文献   

11.
Tendon-to-bone healing following acute injury is generally poor and often fails to restore normal tendon biomechanical properties. In recent years, the murine patellar tendon (PT) has become an important model system for studying tendon healing and repair due to its genetic tractability and accessible location within the knee. However, the mechanical properties of native murine PT, specifically the regional differences in tissue strains during loading, and the biomechanical outcomes of natural PT-to-bone healing have not been well characterized. Thus, in this study, we analyzed the global biomechanical properties and regional strain patterns of both normal and naturally healing murine PT at three time points (2, 5, and 8 weeks) following acute surgical rupture of the tibial enthesis. Normal murine PT exhibited distinct regional variations in tissue strain, with the insertion region experiencing approximately 2.5 times greater strain than the midsubstance at failure (10.80±2.52% vs. 4.11±1.40%; mean±SEM). Injured tendons showed reduced structural (ultimate load and linear stiffness) and material (ultimate stress and linear modulus) properties compared to both normal and contralateral sham-operated tendons at all healing time points. Injured tendons also displayed increased local strain in the insertion region compared to contralateral shams at both physiologic and failure load levels. 93.3% of injured tendons failed at the tibial insertion, compared to only 60% and 66.7% of normal and sham tendons, respectively. These results indicate that 8 weeks of natural tendon-to-bone healing does not restore normal biomechanical function to the murine PT following injury.  相似文献   

12.
Damage accumulation underlies tendinopathy. Animal models of overuse injuries do not typically control loads applied to the tendon. Our in vivo model in the rat patellar tendon allows direct control of the loading applied to the tendon. Despite this advantage, natural variation among tendons results in different amounts of damage induced by the same loading protocol. Our objectives were to (1) assess changes in the initial mechanical parameters (hysteresis, stiffness of the loading and unloading load-displacement curves, and elongation) after fatigue loading to identify parameters that are indicative of the induced damage, and (2) evaluate the relationships between these identified initial damage indices with the stiffness 7 day after loading. Left patellar tendons of adult, female retired breeder, Sprague-Dawley rats (n = 68) were fatigue loaded per our previously published in vivo fatigue loading protocol. To induce a range of damage, fatigue loading consisted of either 5, 100, 500 or 7200 cycles that ranged from 1 N to 40 N. Diagnostic tests were applied before and immediately after fatigue loading, and after 45 min of recovery to deduce recoverable and non-recoverable changes in initial damage indices. Relationships between these initial damage indices and the 7-day stiffness (at sacrifice) were determined. Day-0 hysteresis, loading and unloading stiffness exhibited cycle-dependent changes. Initial hysteresis loss correlated with the 7-day stiffness. k-means cluster analysis demonstrated a relationship between 7-day stiffness and day-0 hysteresis and unloading stiffness. This analysis also separated samples that exhibited low from high damage in response to both high or low number of cycles; a key delineation for interpretation of the biological response in future studies. Identifying initial parameters that reflect the induced damage is critical since the ability of the tendon to repair depends on the damage induced and the number of applied loading cycles.  相似文献   

13.
Evaluations of tendon mechanical behavior based on biochemical and structural arrangement have implications for designing tendon specific treatment modalities or replacement strategies. In addition to the well studied type I collagen, other important constituents of tendon are the small proteoglycans (PGs). PGs have been shown to vary in concentration within differently loaded areas of tendon, implicating them in specific tendon function. This study measured the mechanical properties of multiple tendon tissues from normal mice and from mice with knock-outs of the PGs decorin or biglycan. Tail tendon fascicles, patellar tendons (PT), and flexor digitorum longus tendons (FDL), three tissues representing different in vivo loading environments, were characterized from the three groups of mice. It was hypothesized that the absence of decorin or biglycan would have individual effects on each type of tendon tissue. Surprisingly, no change in mechanical properties was observed for the tail tendon fascicles due to the PG knockouts. The loss of decorin affected the PT causing an increase in modulus and stress relaxation, but had little effect on the FDL. Conversely, the loss of biglycan did not significantly affect the PT, but caused a reduction in both the maximum stress and modulus of the FDL. These results give mechanical support to previous biochemical data that tendons likely are uniquely tailored to their specific location and function. Variances such as those presented here need to be further characterized and taken into account when designing therapies or replacements for any one particular tendon.  相似文献   

14.
A precise analysis of the mechanical response of collagen fibrils in tendon tissue is critical to understanding the ultrastructural mechanisms that underlie collagen fibril interactions (load transfer), and ultimately tendon structure–function. This study reports a novel experimental approach combining macroscopic mechanical loading of tendon with a morphometric ultrascale assessment of longitudinal and cross-sectional collagen fibril deformations. An atomic force microscope was used to characterize diameters and periodic banding (D-period) of individual type-I collagen fibrils within murine Achilles tendons that were loaded to 0%, 5%, or 10% macroscopic nominal strain, respectively. D-period banding of the collagen fibrils increased with increasing tendon strain (2.1% increase at 10% applied tendon strain, p < 0.05), while fibril diameter decreased (8% reduction, p < 0.05). No statistically significant differences between 0% and 5% applied strain were observed, indicating that the onset of fibril (D-period) straining lagged macroscopically applied tendon strains by at least 5%. This confirms previous reports of delayed onset of collagen fibril stretching and the role of collagen fibril kinematics in supporting physiological tendon loads. Fibril strains within the tissue were relatively tightly distributed in unloaded and highly strained tendons, but were more broadly distributed at 5% applied strain, indicating progressive recruitment of collagen fibrils. Using these techniques we also confirmed that collagen fibrils thin appreciably at higher levels of macroscopic tendon strain. Finally, in contrast to prevalent tendon structure–function concepts data revealed that loading of the collagen network is fairly homogenous, with no apparent predisposition for loading of collagen fibrils according to their diameter.  相似文献   

15.
《Journal of biomechanics》2014,47(16):3794-3798
Tendons are able to transmit high loads efficiently due to their finely optimized hierarchical collagen structure. Two mechanisms by which tendons respond to load are collagen fibril sliding and deformation (stretch). Although many studies have demonstrated that regional variations in tendon structure, composition, and organization contribute to the full tendon׳s mechanical response, the location-dependent response to loading at the fibril level has not been investigated. In addition, the instantaneous response of fibrils to loading, which is clinically relevant for repetitive stretch or fatigue injuries, has also not been studied. Therefore, the purpose of this study was to quantify the instantaneous response of collagen fibrils throughout a mechanical loading protocol, both in the insertion site and in the midsubstance of the mouse supraspinatus tendon. Utilizing a novel atomic force microscopy-based imaging technique, tendons at various strain levels were directly visualized and analyzed for changes in fibril d-period with increasing tendon strain. At the insertion site, d-period significantly increased from 0% to 1% tendon strain, increased again from 3% to 5% strain, and decreased after 5% strain. At the midsubstance, d-period increased from 0% to 1% strain and then decreased after 7% strain. In addition, fibril d-period heterogeneity (fibril sliding) was present, primarily at 3% strain with a large majority occurring in the tendon midsubstance. This study builds upon previous work by adding information on the instantaneous and regional-dependent fibrillar response to mechanical loading and presents data proposing that collagen fibril sliding and stretch are directly related to tissue organization and function.  相似文献   

16.
The effect of loading rate on specimen calibration was investigated for an implantable force sensor of the two-point loading variety. This variety of sensor incorporates a strain gage to measure the compressive load applied to the sensor due to tensile loading in a soft tissue specimen. The Achilles tendon in each of four human cadaveric lower extremities was instrumented with a force sensor and then loaded in tension using a materials testing machine. Each specimen was tensile tested at three different displacement rates, 0.25, 2.5 and 12.7 cm s(-1), corresponding with mean loading rates of 33.8, 513.2, and 2838.6 N s(-1), respectively. A calibration curve relating the force sensor signal and applied tendon tension was generated for each specimen/ displacement rate combination. For each specimen, calibration curves were compared by calculating an RMS error for the entire data set (eRMS = 1.6% of the full load value) and a coefficient of determination, R2, of a curve fit through all of the data (R2 = 99.6%). Over the range of rates tested, no measurable change in sensor sensitivity due to loading rate was observed. Hysteresis for all displacement rates was on the order of 2.4%.  相似文献   

17.
In many muscles, the tendinous structures include both an extramuscular free tendon as well as a sheet-like aponeurosis. In both free tendons and aponeuroses the collagen fascicles are oriented primarily longitudinally, along the muscle's line of action. It is generally assumed that this axis represents the direction of loading for these structures. This assumption is well founded for free tendons, but aponeuroses undergo a more complex loading regime. Unlike free tendons, aponeuroses surround a substantial portion of the muscle belly and are therefore loaded both parallel (longitudinal) and perpendicular (transverse) to a muscle's line of action when contracting muscles bulge to maintain a constant volume. Given this biaxial loading pattern, it is critical to understand the mechanical properties of aponeuroses in both the longitudinal and transverse directions. In this study, we use uniaxial testing of isolated tissue samples from the aponeurosis of the lateral gastrocnemius of wild turkeys to determine mechanical properties of samples loaded longitudinally (along the muscle's line of action) and transversely (orthogonal to the line of action). We find that the aponeurosis has a significantly higher Young's modulus in the longitudinal than in the transverse direction. Our results also show that aponeuroses can behave as efficient springs in both the longitudinal and transverse directions, losing little energy to hysteresis. We also test the failure properties of aponeuroses to quantify the likely safety factor with which these structures operate during muscular force production. These results provide an essential foundation for understanding the mechanical function of aponeuroses as biaxially loaded biological springs.  相似文献   

18.
Tendons in different locations function in unique, and at times complex, invivo loading environments. Specifically, some tendons are subjected to compression, shear and/or torsion in addition to tensile loading, which play an important role in regulating tendon properties. To date, there have been few studies evaluating tendon mechanics when loaded in compression and shear, which are particularly relevant for understanding tendon regions that experience such non-tensile loading during normal physiologic function. The objective of this study was to evaluate mechanical responses of different regions of bovine deep digital flexor tendons (DDFT) under compressive and shear loading, and correlate structural characteristics to functional mechanical properties. Distal and proximal regions of DDFT were evaluated in a custom-made loading system via three-step incremental stress-relaxation tests. A two-relaxation-time solid linear model was used to describe the viscoelastic response. Results showed large differences in the elastic behavior between regions: distal region stresses were 4–5 times larger than proximal region stresses during compression and 2–3 times larger during shear. Surprisingly, the viscous (i.e., relaxation) behavior was not different between regions for either compression or shear. Histological analysis showed that collagen and proteoglycan in the distal region distributed differently from the proximal region. Results demonstrate mechanical differences between two regions of DDFT under compression and shear loading, which are attributed to variations of composition and microstructural organization. These findings deepen our understanding of structure–function relationships of tendon, particularly for tissues adapted to supporting combinations of tension, compression, and shear in physiological loading environments.  相似文献   

19.
Tendons can function as springs and thereby preserve energy during cyclic loading. They might also have damping properties, which, hypothetically, could reduce risk of microinjuries due to fatigue at sites of local stress concentration within the tendon. At mechanical testing, damping will appear as hysteresis. How is damping influenced by training or disuse? Does training decrease hysteresis, thereby making the tendon a better spring, or increase hysteresis and thus improve damping? Seventy-eight female 10-wk-old Sprague-Dawley rats were randomized to three groups. Two groups had botulinum toxin injected into the calf muscles to unload the left Achilles tendon through muscle paralysis. One of these groups was given doxycycline, as a systemic matrix metalloproteinase inhibitor. The third group served as loaded controls. The Achilles tendons were harvested after 1 or 6 wk for biomechanical testing. An increase with time was seen in tendon dry weight, wet weight, water content, transverse area, length, stiffness, force at failure, and energy uptake in all three groups (P < 0.001 for each parameter). Disuse had no effect on these parameters. Creep was decreased with time in all groups. The only significant effect of disuse was on hysteresis (P = 0.004) and creep (P = 0.007), which both decreased with disuse compared with control, and on modulus, which was increased (P = 0.008). Normalized glycosaminoglycan content was unaffected by time and disuse. No effect of doxycycline was observed. The results suggest that in growing animals, the tendons continue to grow regardless of mechanical loading history, whereas maintenance of damping properties requires mechanical stimulation.  相似文献   

20.
Identification of functional programmable mechanical stimulation (PMS) on tendon not only provides the insight of the tendon homeostasis under physical/pathological condition, but also guides a better engineering strategy for tendon regeneration. The aims of the study are to design a bioreactor system with PMS to mimic the in vivo loading conditions, and to define the impact of different cyclic tensile strain on tendon. Rabbit Achilles tendons were loaded in the bioreactor with/without cyclic tensile loading (0.25 Hz for 8 h/day, 0–9% for 6 days). Tendons without loading lost its structure integrity as evidenced by disorientated collagen fiber, increased type III collagen expression, and increased cell apoptosis. Tendons with 3% of cyclic tensile loading had moderate matrix deterioration and elevated expression levels of MMP‐1, 3, and 12, whilst exceeded loading regime of 9% caused massive rupture of collagen bundle. However, 6% of cyclic tensile strain was able to maintain the structural integrity and cellular function. Our data indicated that an optimal PMS is required to maintain the tendon homeostasis and there is only a narrow range of tensile strain that can induce the anabolic action. The clinical impact of this study is that optimized eccentric training program is needed to achieve maximum beneficial effects on chronic tendinopathy management. Biotechnol. Bioeng. 2013; 110: 1495–1507. © 2012 Wiley Periodicals, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号