1.
W. S. Remkes R. S. Hermanides M. W. Kennedy E. Fabris E. Kaplan J. P. Ottervanger A. W. J. van ’t Hof E. Kedhi 《Netherlands heart journal》2017,25(11):611-617
Background
Recent evidence has raised concerns regarding the safety of the everolimus-eluting bioresorbable vascular scaffold (E-BVS) (Absorb, Abbott Vascular, Santa Clara, CA, USA). Following these data, the use of this device has diminished in the Netherlands; however, daily practice data are limited. Therefore we studied the incidence of safety and efficacy outcomes with this device in daily clinical practice in a single large tertiary centre in the Netherlands.Methods
All E?BVS treated patients were included in this analysis. The primary endpoint was target lesion failure (TLF), a composite of cardiac death, target vessel non-fatal myocardial infarction (TV-MI) and clinically-driven target lesion revascularisation (TLR). The secondary endpoint was the incidence of definite scaffold thrombosis.Results
Between October 2013 and January 2017, 105 patients were treated with 147 E?BVS. This population contained 42 (40%) patients with diabetes mellitus and 43 (40.9%) undergoing treatment for acute coronary syndrome, and thus represents a high-risk patient cohort. Mean follow-up was 19.8 months. Intravascular imaging guidance during scaffold implantation was used in 64/105 (43.5%) patients. The primary endpoint (TLF) occurred in 3 (2.9%) patients. All-cause mortality and cardiac mortality occurred in 2 (2%) and 0 (0%) patients respectively. TV-MI occurred in 2 patients (1.9%): both were periprocedural and not related to the BVS implantation. TLR occurred in 1 patient (1.0%) during follow-up. No definite scaffold thrombosis occurred during follow-up.Conclusion
This single-centre study examining the real-world experience of E?BVS implantation in a high-risk population shows excellent procedural safety and long-term clinical outcomes.2.
R. Rozemeijer M. Voskuil J. P. Greving M. L. Bots P. A. Doevendans P. R. Stella 《Netherlands heart journal》2018,26(5):242-251
Background
Dual antiplatelet therapy (DAPT) remains the cornerstone therapy in the prevention of ischaemic events following drug-eluting stent (DES) implantation. Mandatory duration of DAPT after DES however, is a matter of debate. We aimed to evaluate safety and efficacy of short-term (up to 6 months) versus long-term (12 months) DAPT after DES implantation.Methods
We searched PubMed, EMBASE, Cochrane databases, and international meetings for randomised clinical trials (RCTs) comparing short with long DAPT. We performed a systematic review and meta-analysis of major trials with primary outcomes: all-cause death, myocardial infarction, definite or probable stent thrombosis, stroke, and major bleeding event.Results
Nine RCTs with a total number of 19,099 patients were pooled in the present meta-analysis. When compared with long DAPT, short DAPT was associated with a significant reduction in major bleeding events (0.62% vs. 1.10%, risk ratio (RR) 0.58, 95% confidence interval (CI) 0.39 to 0.86, p?<?0.007, I2?=?21%), whereas all-cause death (1.65% vs. 1.84%, RR 0.90, 95% CI 0.73 to 1.11, p?=?0.34, I2?=?0%), myocardial infarction (1.91% vs. 1.68%, RR 1.14, 95% CI 0.92 to 1.40, p?=?0.23, I2?=?0%), definite or probable stent thrombosis (0.62% vs. 0.47%, RR 1.25, 95% CI 0.84 to 1.86, p?=?0.27, I2?=?0%), and stroke (0.60% vs. 0.67%, RR 0.91, 95% CI 0.63 to 1.31, p?=?0.61, I2?=?0%) were similar.Conclusions
Short DAPT following DES implantation results in a significant reduction of major bleeding events with no apparent increase in all-cause death, myocardial infarction, stent thrombosis, or stroke. Future dedicated trials should investigate the optimal strategies for patient-tailored DAPT in various subgroups.3.
A. J. J. IJsselmuiden E. M. Zwaan R. M. Oemrawsingh M. J. Bom F. J. W. M. Dankers M. J. de Boer C. Camaro R. J. M. van Geuns J. Daemen D. J. van der Heijden J. W. Jukema A. O. Kraaijeveld M. Meuwissen B. E. Schölzel G. Pundziute P. van der Harst J. van Ramshorst M. T. Dirksen C. Zivelonghi P. Agostoni J. A. S. van der Heyden J. J. Wykrzykowska M. J. Scholte H. M. Nef M. J. M. Kofflard N. van Royen M. Alings E. Kedhi 《Netherlands heart journal》2018,26(10):473-483
Introduction
Optical coherence tomography (OCT) enables detailed imaging of the coronary wall, lumen and intracoronary implanted devices. Responding to the lack of specific appropriate use criteria (AUC) for this technique, we conducted a literature review and a procedure for appropriate use criteria.Methods
Twenty-one of all 184 members of the Dutch Working Group on Interventional Cardiology agreed to evaluate 49 pre-specified cases. During a meeting, factual indications were established whereupon members individually rated indications on a 9-point scale, with the opportunity to substantiate their scoring.Results
Twenty-six indications were rated ‘Appropriate’, eighteen indications ‘May be appropriate’, and five ‘Rarely appropriate’. Use of OCT was unanimously considered ‘Appropriate’ in stent thrombosis, and ‘Appropriate’ for guidance in PCI, especially in distal left main coronary artery and proximal left anterior descending coronary artery, unexplained angiographic abnormalities, and use of bioresorbable vascular scaffold (BVS). OCT was considered ‘Rarely Appropriate’ on top of fractional flow reserve (FFR) for treatment indication, assessment of strut coverage, bypass anastomoses or assessment of proximal left main coronary artery.Conclusions
The use of OCT in stent thrombosis is unanimously considered ‘Appropriate’ by these experts. Varying degrees of consensus exists on the appropriate use of OCT in other settings.4.
5.
P. W. A. Janssen D. M. F. Claassens L. M. Willemsen T. O. Bergmeijer P. Klein J. M. ten Berg 《Netherlands heart journal》2017,25(9):482-489
Background
International guidelines do not provide uniform recommendations regarding the use of antiplatelet treatment in the perioperative period in patients undergoing coronary artery bypass grafting (CABG).Methods
A questionnaire was sent to all 16 cardiothoracic centres in the Netherlands to determine which antiplatelet treatment is used in the perioperative setting. Furthermore, a single-centre prospective observational cohort study was performed which included all patients undergoing isolated CABG in July 2014.Results
Eleven centres responded to the survey. Acetylsalicylic acid monotherapy was discontinued before surgery in 6 centres. In patients with an acute coronary syndrome receiving dual antiplatelet therapy (DAPT), most centres discontinued the P2Y12 inhibitor preoperatively. DAPT was restarted after surgery in 4 centres. However, 6 centres continued DAPT in patients who had undergone coronary stenting within one month of surgery. In patients with coronary stents, variation in the management of antiplatelet therapy increased in proportion to the interval between stenting and surgery. A total of 70 patients were included in the registry. Acetylsalicylic acid monotherapy was discontinued in 51% of patients and restarted in all patients. P2Y12 inhibitor treatment was discontinued before surgery in 70% of patients and re-initiated after CABG in 29%.Conclusions
Major differences were observed in the preoperative and postoperative management of antiplatelet treatment between different Dutch cardiothoracic centres and within a single centre. Part of this variation is probably due to lack of evidence and differences between the current guidelines; however, many of the strategies were not in accordance with any of these guidelines.6.
Marta Michalczuk Beata Urban Tadeusz Porowski Anna Wasilewska Alina Bakunowicz-Łazarczyk 《Metabolomics : Official journal of the Metabolomic Society》2018,14(6):82
Introduction
Citrate is an old metabolite which is best known for the role in the Krebs cycle. Citrate is widely used in many branches of medicine. In ophthalmology citrate is considered as a therapeutic agent and an useful diagnostic tool—biomarker.Objectives
To summarize the published literature on citrate usage in the leading causes of blindness and highlight the new possibilities for this old metabolite.Methods
We conducted a systematic search of the scientific literature about citrate usage in ophthalmology up to January 2018. The reference lists of identified articles were searched for providing in-depth information.Results
This systematic review included 30 articles. The role of citrate in the leading causes of blindness is presented.Conclusions
Citrate might help inhibit cataract progression, in case of questions confirm glaucoma diagnosis or improve cornea repair treatment as adjuvant agent (therapy of ulcerating cornea after alkali injury, crosslinking procedure). However, the knowledge about possible citrate usage in ophthalmology is not widely known. Promoting recent scientific knowledge about citrate usage in ophthalmology may not only benefit of medical improvement but may also limit economic costs caused by leading causes of blindness. Further studies on citrate usage in ophthalmology should continuously be the field of scientific interest.7.
Haoran Hu Peipei Zhao Jiayu Liu Qinfei Ke Changqing Zhang Yaping Guo Hao Ding 《Journal of nanobiotechnology》2018,16(1):98
Background
Fabrication of porous scaffolds with great biocompatibility and osteoinductivity to promote bone defect healing has attracted extensive attention.Methods
In a previous study, novel lanthanum phosphate (LaPO4)/chitosan (CS) scaffolds were prepared by distributing 40- to 60-nm LaPO4 nanoparticles throughout plate-like CS films.Results
Interconnected three dimensional (3D) macropores within the scaffolds increased the scaffold osteoconductivity, thereby promoting cell adhesion and bone tissue in-growth. The LaPO4/CS scaffolds showed no obvious toxicity and accelerated bone generation in a rat cranial defect model. Notably, the element La in the scaffolds was found to promote osteogenic differentiation of bone marrow mesenchymal stem cells (BMSCs) through the Wnt/β-catenin signalling pathway and induced high expression of the osteogenesis-related genes alkaline phosphatase, osteocalcin and Collagen I (Col-I). Moreover, the LaPO4/CS scaffolds enhanced bone regeneration and collagen fibre deposition in rat critical-sized calvarial defect sites.Conclusion
The novel LaPO4/CS scaffolds provide an admirable and promising platform for the repair of bone defects.8.
Yonghua Bi Jindong Li Zepeng Yu Jianzhuang Ren Gang Wu Xinwei Han 《BMC pulmonary medicine》2018,18(1):182
Background
Metallic large Y stent placement has been used mainly for airway disease around the main carina. However, few studies have reported this treatment for bronchial disease around the primary right carina.Methods
Twenty-eight patients were treated by small y stent. All stents were custom-designed and placed under fluoroscopic guidance. Clinical and imaging data were analyzed retrospectively.Results
Thirty-one stents were successfully inserted in 28 patients. Twenty-five patients succeed at the first attempt (89.3%), and 3 patients needed a second attempt. Twelve complications occurred in 10 patients (35.7%). Stent restenosis and sputum retention were the most common complications. Five patients underwent successful stent removal due to complications or cure efficacy. During follow up, 17 patients died of tumors and one died of myocardial infarction. The 1-, 3-, and 5-year survival rates were 49.3, 19.6 and 19.6%, respectively.Conclusions
Metallic small y stent placement is technically feasible, effective and safe for bronchial disease around the primary right carina.9.
N. Cesbron A.-L. Royer Y. Guitton A. Sydor B. Le Bizec G. Dervilly-Pinel 《Metabolomics : Official journal of the Metabolomic Society》2017,13(8):99
Introduction
Collecting feces is easy. It offers direct outcome to endogenous and microbial metabolites.Objectives
In a context of lack of consensus about fecal sample preparation, especially in animal species, we developed a robust protocol allowing untargeted LC-HRMS fingerprinting.Methods
The conditions of extraction (quantity, preparation, solvents, dilutions) were investigated in bovine feces.Results
A rapid and simple protocol involving feces extraction with methanol (1/3, M/V) followed by centrifugation and a step filtration (10 kDa) was developed.Conclusion
The workflow generated repeatable and informative fingerprints for robust metabolome characterization.10.
J. Elias I. M. van Dongen R. P. Kraak R. Y. G. Tijssen B. E. P. M. Claessen J. G. P. Tijssen R. J. de Winter J. J Piek J. J. Wykrzykowska J. P. S. Henriques 《Netherlands heart journal》2017,25(7-8):429-438
Aims
Mid- and long-term safety and efficacy of the Absorb bioresorbable vascular scaffold (BVS) have been studied in randomised trials; however, most were not individually powered for clinical endpoints. We performed a weighted meta-analysis comparing mid- and long-term outcomes in patients treated with the BVS compared with the Xience metallic stent.Methods and results
Randomised trials comparing the BVS and Xience were identified by searching MEDLINE, EMBASE and conference abstracts. Seven trials were included (BVS n = 3258, Xience n = 2319) with follow-up between 1–3 years. The primary outcome of target lesion failure occurred more frequently in BVS compared with Xience [OR 1.34; 95% CI 1.11–1.62, p = 0.003]. Overall definite or probable device thrombosis occurred more frequently with the BVS [OR 2.86; 95% CI 1.88–4.36, p < 0.001] and this extended beyond 1 year of follow-up [OR 4.13; 95% CI 1.99–8.57, p < 0.001]. Clinically indicated or ischaemia driven target lesion revascularisation [OR 1.43; 95% CI 1.11–1.83, p = 0.005] and myocardial infarction (all MI) [OR 1.64; 95% CI 1.20–2.23, p = 0.002] were more frequently seen in the BVS compared with Xience. Rates of target vessel failure [OR 1.15; 95% CI 0.91–1.46, p = 0.25] and cardiac death [OR 0.91; 95% CI 0.57–1.46, p = 0.71] were not significantly different between BVS and Xience.Conclusion
This meta-analysis shows a higher rate of target lesion failure and an almost threefold higher rate of device thrombosis in BVS compared with Xience, which extends beyond the first year. Device thrombosis did not lead to an overall increased (cardiac) mortality.11.
Yu Chen Yan Xiong Wentao Jiang Fei Yan Meng Guo Qingyuan Wang Yubo Fan 《Biomedical engineering online》2015,14(Z1):S16
Background
The changes of hemodynamics and drug concentration distribution caused by the implantation of drug eluting stents (DESs) in curved vessels have significant effects on In-Stent Restenosis.Methods
A 3D virtual stent with 90°curvature was modelled and the distribution of wall shear stress (WSS) and drug concentration in this model were numerically studied at Reynolds numbers of 200, 400, 600, 800.Results
The results showed that (1) the intensity of secondary flow at the 45° cross-section was stronger than that at the 90° cross-section; (2) As the Reynolds number increases, the WSS decreases. When the Reynolds number reaches 600, the low-WSS region only accounts for 3% of the total area. (3) The effects of Reynolds number on drug concentration in the vascular wall decreases in proportionally and then the blood velocity increased 4 times, the drug concentration in the vascular wall decreased by about 30%. (4) The size of the high drug concentration region is inversely proportional to the Reynolds number. As the blood velocity increases, the drug concentration in the DES decreases, especially at the outer bend.Conclusions
It is beneficial for the patient to decrease vigorous activities and keep calm at the beginning of the stent implantation, because a substantial amount of the drug is released in the first two months of stent implantation, thus a calm status is conducive to drug release and absorption; Subsequently, appropriate exercise which increases the blood velocity is helpful in decreasing regions of low-WSS.12.
Background
Adverse events from Melody valve implantation may be catastrophic. To date a role for three dimensional rotational angiography of the aortic root (3DRAA) during Melody valve implantation has not been established.Objectives
To describe the role of 3DRAA in the assessment of Melody valve candidacy and to demonstrate that it may improve outcomes.Methods
All patients who underwent cardiac catheterisation for Melody valve implantation and 3DRAA between August 2013 and February 2015 were reviewed.Results
31 patients had 3DRAA with balloon sizing. Ten were deemed not Melody candidates (5 coronary compression, 2 aortic root distortion with cusp flattening, 2 RVOT was too large, and 1 had complex branch stenosis and a short landing zone). Of the 21 patients who were Melody candidates, 12 had conduits, 6 prosthetic valves and 3 native RVOTs. In patients with conduits, the technique of stenting the conduit prior to dilation was used after measuring the distance between the conduit and the coronary arteries on 3DRAA. In the Melody patients, we had 100% procedural success and no serious adverse events (coronary compression, tears, stent fracture or endocarditis).Conclusion
As a tool for case selection, 3DRAA may facilitate higher procedural success and decreased risk of serious adverse events. Furthermore, 3D rotational angiography allows stenting of the conduit prior to dilation, which may prevent tears and possibly endocarditis.13.
Meghan E. Hall Nima Khadem Mohtaram Stephanie M. Willerth 《Journal of biological engineering》2017,11(1):38
Background
Human induced pluripotent stem cells (hiPSCs) can form any tissue found in the body, making them attractive for regenerative medicine applications. Seeding hiPSC aggregates into biomaterial scaffolds can control their differentiation into specific tissue types. Here we develop and analyze a mathematical model of hiPSC aggregate behavior when seeded on melt electrospun scaffolds with defined topography.Results
We used ordinary differential equations to model the different cellular populations (stem, progenitor, differentiated) present in our scaffolds based on experimental results and published literature. Our model successfully captures qualitative features of the cellular dynamics observed experimentally. We determined the optimal parameter sets to maximize specific cellular populations experimentally, showing that a physiologic oxygen level (~?5%) increases the number of neural progenitors and differentiated neurons compared to atmospheric oxygen levels (~?21%) and a scaffold porosity of ~?63% maximizes aggregate size.Conclusions
Our mathematical model determined the key factors controlling hiPSC behavior on melt electrospun scaffolds, enabling optimization of experimental parameters.14.
Rachel A. Spicer Christoph Steinbeck 《Metabolomics : Official journal of the Metabolomic Society》2018,14(1):16
Introduction
Data sharing is being increasingly required by journals and has been heralded as a solution to the ‘replication crisis’.Objectives
(i) Review data sharing policies of journals publishing the most metabolomics papers associated with open data and (ii) compare these journals’ policies to those that publish the most metabolomics papers.Methods
A PubMed search was used to identify metabolomics papers. Metabolomics data repositories were manually searched for linked publications.Results
Journals that support data sharing are not necessarily those with the most papers associated to open metabolomics data.Conclusion
Further efforts are required to improve data sharing in metabolomics.15.
Introduction
Untargeted metabolomics is a powerful tool for biological discoveries. To analyze the complex raw data, significant advances in computational approaches have been made, yet it is not clear how exhaustive and reliable the data analysis results are.Objectives
Assessment of the quality of raw data processing in untargeted metabolomics.Methods
Five published untargeted metabolomics studies, were reanalyzed.Results
Omissions of at least 50 relevant compounds from the original results as well as examples of representative mistakes were reported for each study.Conclusion
Incomplete raw data processing shows unexplored potential of current and legacy data.16.
Background
In recent years the visualization of biomagnetic measurement data by so-called pseudo current density maps or Hosaka-Cohen (HC) transformations became popular.Methods
The physical basis of these intuitive maps is clarified by means of analytically solvable problems.Results
Examples in magnetocardiography, magnetoencephalography and magnetoneurography demonstrate the usefulness of this method.Conclusion
Hardware realizations of the HC-transformation and some similar transformations are discussed which could advantageously support cross-platform comparability of biomagnetic measurements.17.
Renato de Souza Pinto Lemgruber Kaspar Valgepea Mark P. Hodson Ryan Tappel Sean D. Simpson Michael Köpke Lars K. Nielsen Esteban Marcellin 《Metabolomics : Official journal of the Metabolomic Society》2018,14(3):35
Introduction
Quantification of tetrahydrofolates (THFs), important metabolites in the Wood–Ljungdahl pathway (WLP) of acetogens, is challenging given their sensitivity to oxygen.Objective
To develop a simple anaerobic protocol to enable reliable THFs quantification from bioreactors.Methods
Anaerobic cultures were mixed with anaerobic acetonitrile for extraction. Targeted LC–MS/MS was used for quantification.Results
Tetrahydrofolates can only be quantified if sampled anaerobically. THF levels showed a strong correlation to acetyl-CoA, the end product of the WLP.Conclusion
Our method is useful for relative quantification of THFs across different growth conditions. Absolute quantification of THFs requires the use of labelled standards.18.
Jamie V. de Seymour Stephanie Tu Xiaoling He Hua Zhang Ting-Li Han Philip N. Baker Karolina Sulek 《Metabolomics : Official journal of the Metabolomic Society》2018,14(6):79
Introduction
Intrahepatic cholestasis of pregnancy (ICP) is a common maternal liver disease; development can result in devastating consequences, including sudden fetal death and stillbirth. Currently, recognition of ICP only occurs following onset of clinical symptoms.Objective
Investigate the maternal hair metabolome for predictive biomarkers of ICP.Methods
The maternal hair metabolome (gestational age of sampling between 17 and 41 weeks) of 38 Chinese women with ICP and 46 pregnant controls was analysed using gas chromatography–mass spectrometry.Results
Of 105 metabolites detected in hair, none were significantly associated with ICP.Conclusion
Hair samples represent accumulative environmental exposure over time. Samples collected at the onset of ICP did not reveal any metabolic shifts, suggesting rapid development of the disease.19.
S. Goreczny T. Moszura P. Dryzek M. Lukaszewski A. Krawczuk J. Moll G. J. Morgan 《Netherlands heart journal》2017,25(2):91-99
Introduction
Three-dimensional rotational angiography (3DRA) has been used in the guidance of various transcatheter therapies including percutaneous pulmonary valve implantation (PPVI). The most recently available 3D image fusion software (VesselNavigator, Philips) extends this technology to use pre-registered computed tomography or magnetic resonance imaging datasets, promising reductions in contrast and radiation exposure along with shorter procedural times.Methods
In this retrospective review, patients were assigned to three groups according to the mode of imaging guidance: two-dimensional angiography (2DA), 3DRA and VesselNavigator (VN) assisted valve implantation. Patient characteristics and catheterisation data were reviewed with a focus on contrast and radiation exposure, fluoroscopy, and procedural times.Results
Between July 2012 and June 2016, 21 patients underwent PPVI: 8 with 2D guidance, 6 patients with 3DRA and most recently 7 patients with VN assistance. Patents in the VN group received significantly less absolute and weight indexed contrast when compared with those with 2DA or 3DRA guided PPVI. Patients in the 2DA group received a significantly higher total dose area product radiation dose and air kerma in comparison with patients with 3DRA and VN guided intervention. Application of VN resulted in the shortest fluoroscopy time, although not statistically significant, and a significantly shorter study time when compared with 2DA.Conclusions
Utilisation of pre-intervention image manipulation with VesselNavigator for 3D guidance of PPVI results in a reduction in contrast and radiation exposure and study time as compared with traditional 2D guidance, and contrast usage as compared with 3DRA.20.
Ferran Casbas Pinto Srinivarao Ravipati David A. Barrett T. Charles Hodgman 《Metabolomics : Official journal of the Metabolomic Society》2017,13(7):81