共查询到20条相似文献,搜索用时 15 毫秒
1.
Bunch DR Heideloff C Ritchie JC Wang S 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(31):3255-3258
Busulfan is used in myeloablative preparation regimens for hematopoietic bone marrow transplantation. Due to its narrow therapeutic range therapeutic drug monitoring of busulfan is recommended. In this study a fast and simple method for measuring busulfan in serum or plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed utilizing turbulent flow online extraction technology. Serum or plasma was mixed with acetonitrile containing d(8)-busulfan. After centrifugation the supernatant was injected onto a turbulent flow preparatory column then transferred to a C18 analytical column monitored by a tandem mass spectrometer set at positive electrospray ionization. The analytical cycle time was 4.0min. The method was linear from 0.15 to 41.90μmol/L with an accuracy of 87.9-103.0%. Inter- and intra-assay CVs across four concentration levels were 2.1-7.8%. No significant carryover or ion suppression was observed. No interference was observed from commercial control materials containing more than 100 compounds. Comparison with a well established LC-MS/MS method using patient specimens (n=45) showed a mean bias 1.3% with Deming regression of slope 1.02, intercept -0.02μmol/L, and a linear correlation coefficient 0.9883. The LC-MS/MS method coupled with turbulent flow online sample cleaning technology described here offers reliable busulfan quantitation in serum or plasma with minimum manual sample preparation and was fully validated for clinical use. 相似文献
2.
Superiority of gas chromatography/tandem mass spectrometry assay (GC/MS/MS) for estradiol for monitoring of aromatase inhibitor therapy 总被引:5,自引:0,他引:5
Santen RJ Demers L Ohorodnik S Settlage J Langecker P Blanchett D Goss PE Wang S 《Steroids》2007,72(8):666-671
Currently available radioimmunoassay methods for estradiol in serum lack sufficient sensitivity and precision to monitor estradiol levels in patients placed on third generation aromatase inhibitors. We recently validated a gas chromatography/tandem mass spectrometry assay (GC/MS/MS) for estradiol and determined estrogen levels in normal post-menopausal women and in women with breast cancer before and during administration of aromatase inhibitors. Validation of the GC/MS/MS assay in human plasma and human serum included determination of assay sensitivity (<0.63 pg/ml), precision (all CVs less than 17.8%), recovery (98-103%), and linearity of recovery (R=0.998). Levels of estradiol were lower when assayed by GC/MS/MS compared to RIA under all conditions (7.26+/-4.82 pg/ml versus 11.9+12.0 pg/ml in normal post-menopausal women; 5.88+/-3.43 pg/ml versus 13.8+/-7.5 pg/ml in breast cancer patients prior to treatment; and<0.63 pg/ml versus 5.8+/-4.1 pg/ml during aromatase inhibitor therapy). Fifty-five women treated either with atamestane/toremiphene or letrozole/placebo were monitored for estradiol levels at 4, 8 and 12 weeks of therapy. The mean levels of estradiol during aromatase inhibitor therapy was 5.8+/-4.1 pg/ml as measured by RIA and <0.63 pg/ml by GC/MS/MS. The degree of suppression with the aromatase inhibitors as detected by RIA was 58% versus >89% by GC/MS. These results suggest that most RIA methods detect cross-reacting estrogen metabolites and yield higher measured levels than GC/MS/MS. Several pharmacological and clinical considerations suggest that GC/MS/MS should become the preferred method for monitoring aromatase inhibitor therapy. 相似文献
3.
Grace PB Taylor JI Botting NP Fryatt T Oldfield MF Bingham SA 《Analytical biochemistry》2003,315(1):114-121
Phytoestrogens (isoflavones and lignans) are of increasing interest due to their potential to prevent certain types of complex diseases. However, epidemiological evidence is needed on the levels of phytoestrogens and their metabolites in foods and biological fluids in relation to risk of these diseases. We report an assay for phytoestrogens which is sensitive, accurate, and uses low volumes of sample. Suitable for epidemiological studies, the assay consists of a simple sample preparation procedure and has been developed for the analysis of five isoflavones (daidzein, O-desmethylangolensin, equol, genistein, and glycitein) and two lignans (enterodiol and enterolactone), which requires only 200 microl of urine and utilizes one solid-phase extraction stage for sample preparation prior to derivatization for GC/MS analysis. Limits of detection were in the region 1.2 ng/ml (enterodiol) to 5.3ng/ml (enterolactone) and the method performed well in the UK Government's Food Standards Agency-sponsored quality assurance scheme for phytoestrogens. For the first time, average levels of all the above phytoestrogens were measured in samples of urine collected from a free living population sample of women. Results show a large range in both the amount and the type of phytoestrogens excreted. 相似文献
4.
Determination of sitagliptinin human plasma using protein precipitation and tandem mass spectrometry
Wei Zeng Yang XuMarvin Constanzer Eric J. Woolf 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(21):1817-1823
A simple offline LC–MS/MS method for the quantification of sitagliptin in human plasma is described. Samples are prepared using protein precipitation. Filtration of the supernatants through a Hybrid-SPE-PPT plate was found to be necessary to reduce ionization suppression caused by co-elution of phospholipids with sitagliptin. The sitagliptin and its stable isotope labeled internal standard (IS) were chromatographed under hydrophilic interaction chromatography conditions on a Waters Atlantis HILIC Silica column (2.1 mm × 50 mm, 3 μm) using a mobile phase of ACN/H2O (80/20, v/v) containing 10 mM NH4Ac (pH 4.7). The sample drying after protein precipitation due to high organic content in the sample is not necessary, because HILIC column was used. The analytes were detected with a tandem mass spectrometer employing a turbo ion spray (TIS) interface in positive ionization mode. The multiple reaction monitoring (MRM) transitions were m/z 408 → 235 for sitagliptin and m/z 412 → 239 for IS. The lower limit of quantitation (LLOQ) for this method is 1 ng/mL when 100 μL of plasma is processed. The linear calibration range is 1–1000 ng/mL for sitagliptin. Intra-day precision and accuracy were assessed based on the analysis of six sets of calibration standards prepared in six lots of human control plasma. Intra-day precision (RSD%, n = 6) ranged from 1.2% to 6.1% and the intra-day accuracy ranged from 97.6% to 103% of nominal values. 相似文献
5.
6.
Pascal Mottier Eric Gremaud Philippe A Guy Robert J Turesky 《Analytical biochemistry》2002,301(1):128-135
Two mass spectrometric methods were established for the quantitative analyses of alpha-tocopherol (TH) and its oxidation product alpha-tocopherolquinone (TQ) in human plasma. Both methods make use of isotopically labeled internal standards of different levels of deuteration (d3-TH and d6-TQ). Plasma (100 microl) was saponified in the presence of a mixture of antioxidants, and then TH and TQ were extracted with hexane. With the GC-MS method, the analytes were first converted into O-trimethylsilyl derivatives before analysis in the selective ion monitoring mode. The derivatization procedure led to the quantitative conversion of TQ into the O-trimethylsilyl derivative of tocopherolhydroquinone, giving rise to a more stable molecule with less fragmentation than for TQ. The increased stability of the molecule resulted in an enhanced contribution of the base peak to the total observed ions and therefore an increased sensitivity of the base peak for quantification. With the liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, TH and TQ were detected by multiple reaction monitoring after positive electrospray ionization. The GC-MS and LC-MS/MS methods showed nearly the same accuracy (>95%) and the same within-day precisions, with less than 5 and 10% for TH and TQ, respectively. The between-day precision and the limit of quantification for TQ in plasma were better by LC-MS/MS (4%; 3 nM) than by GC-MS (21%; 10 nM). Analysis and method validation were carried out with plasma samples obtained from a male volunteer pre- and postexercise. Both techniques showed that the ratio of TQ/TH was elevated by 35% immediately after exercise and had returned to basal levels when measured 24 h later. 相似文献
7.
Quantification of protein calibrants by amino acid analysis using isotope dilution mass spectrometry
This work demonstrates that amino acid analysis based on isotope dilution mass spectrometry (IDMS) can be applied to quantify proteins having different complexities and natures. Five proteins and one decapeptide were selected for the study: C-reactive protein (CRP), beta-2-microglobulin (B2 M), cystatine C (CysC), human serum albumin (HSA), Ara h1, and angiotensin I. The quantification was based on the determination of four amino acids, proline (Pro), isoleucine (Ile), valine (Val), and phenylalanine (Phe) within a working range between 5 and 100 pmol/injection of each amino acid, after 60 min digestion with HCl at 150 °C. The amino acids were selected taking into account their abundance in the protein sequence and to include the more difficult to break peptide bonds. Quantification of the protein amounts calculated from each amino acid is consistent, indicating that the method is working reliably. This consistency points to a complete hydrolysis of the proteins. The trueness of the method was proven when dry mass determination after dialysis was applied to HSA and CRP and the results were compared to those from amino acid analysis. Traceability to SI was assured by extensive characterisation of the amino acid calibrants by nuclear magnetic resonance, neutron activation analysis, and Karl Fischer titration. 相似文献
8.
Yu J Han KS Lee G Paik MJ Kim KR 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(31):3249-3254
The enantioseparation of pranoprofen after its addition in racemic form into equine plasma and urine was conducted by chiral liquid chromatography-tandem mass spectrometry in selected reaction monitoring mode. The methods for the assay of both enantiomers were linear (r≥0.9943) in the low range from 0.001 to 0.1μg/mL and high range from 0.01 to 1.0μg/mL with good precision (% RSD≤5.6) and accuracy (% RE=-5.3 to 1.9). When racemic pranoprofen was orally administered to four horses at a single dose of 3.1mg/kg, the median plasma concentrations of (R)-pranoprofen were lower than the levels of (S)-pranoprofen from start to finish. In contrast, the urinary level of (R)-pranoprofen was 2.5 fold higher than (S)-pranoprofen level for the first 6h, followed by its rapid decrease down below (S)-pranoprofen concentration. Monitoring of the R/S ratios in equine urine may be useful for the prevention of false positive in horse doping test. 相似文献
9.
Biomolecular interaction analysis mass spectrometry (BIA/MS) is a two-dimensional analytical technique that quantitatively and qualitatively detects analytes of interests. In the first dimension, surface plasmon resonance (SPR) is utilized for detection of biomolecules in their native environment. Because SPR detection is non-destructive, analyte(s) retained on the SPR-active sensor surface can be analyzed in a second dimension using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. The qualitative nature of the MALDI-TOF MS analysis complements the quantitative character of SPR sensing and overcomes the shortcomings of the SPR detection stemming from the inability to differentiate and characterize multi-protein complexes and non-specific binding. In this work, the benefit of performing MS analysis following SPR sensing is established. Retrieval and detection of four markers present in biological fluids (cystatin C, beta-2-microglobulin, urinary protein 1 and retinol binding protein) was explored to demonstrate the effectiveness of BIA/MS in simultaneous detection of clinically related biomarkers and delineation of non-specific binding. Furthermore, the BIA/MS limit of detection at very low SPR responses was investigated. Finally, detection of in-vivo assembled protein complexes was achieved for the first time using BIA/MS. 相似文献
10.
Kłys M Rojek S Bolechała F 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2005,825(1):38-46
A typical use of hair analysis in forensic toxicology is the documentation of previous drug administration. This is illustrated in a suicidal death of a 58-year-old epileptic patient who was treated with oxcarbazepine and probably with levomepromazine. The toxicological analysis carried out by HPLC/APCI/MS included also the hair (6 cm length) besides postmortem blood. The method was validated for levomepromazine, oxcarbazepine (OXCBZ) and its two metabolites, 10-hydroxycarbazepine (CBZ-10OH) and trans-diol-carbazepine (CBZ-diOH) in various biological matrices. The analysis of the postmortem blood indicated oxcarbazepine and its two main metabolites were present at therapeutic concentrations; levomepromazine was detected at a fatal concentration. In three 2-cm segments of hair, oxcarbazepine and its two metabolites were detected; however, levomepromazine was not detected in this specimen. As a result of complex chemical-toxicological investigation it was confirmed the information that the decedent. was an epileptic patient and was treated with oxcarbazepine for at least 6 months before death. In addition, he took a toxic dose of levomepromazine in order to commit suicide. The analysis revealed differences between the concentration levels of oxcarbazepine and its active metabolite CBZ-10OH in postmortem specimens and hair, suggesting different mechanisms of penetration of metabolites and their precursors into this matrix. 相似文献
11.
Avery LB Parsons TL Meyers DJ Hubbard WC 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(31):3217-3224
A combined UPLC-tandem mass spectrometric (UPLC-MS/MS) technique has been validated for quantitation of protein free efavirenz (EFV) as well as total concentrations of EFV in human blood and seminal plasma. The analytical method possesses capabilities for concentration measurements of EFV ranging from 0.5 to 10,000ng/ml with an accuracy (%dev) of -5.2-8.0% and precision (%CV) of <8%. Standard curves were linear with coefficients of variation (r(2)) >0.98. The method employs a racemic fluorinated analog of EFV (F-EFV) as the internal standard. EFV and F-EFV were eluted from a reverse-phase UPLC column via gradient elution with detection via negative ion multiple reaction monitoring (MRM). EFV and F-EFV, respectively, were detected via the following MRM transitions: m/z 314.0>244.1 and m/z 298.0>227.9. The time required for the analysis of each sample was 8.0min. The analytical technique is capable of a reliable detection limit of ~15-20fmol of EFV injected on column. 相似文献
12.
《Bioscience, biotechnology, and biochemistry》2013,77(11):2218-2221
Glyphosate and glufosinate are non-selective herbicides that have been extensively used worldwide. Their ionic and water-soluble characteristics often make it difficult to analyze them, especially in food components. A method was developed in this study for the simultaneous analysis of glyphosate, glufosinate, and three metabolic products in beer, barley tea, and their ingredients (malt and corn). The analytical samples were extracted with H2O, purified with a strong anion-exchange solid-phase extraction (SPE) cartridge, and then analyzed by liquid chromatography tandem mass spectrometry (LC-MS/MS) with an anion-exchange high-performance liquid chromatography (HPLC) column. This method enabled a rapid and sensitive analysis [limit of quantification (LOQ) = 10 µg/kg] of the herbicides to be achieved. 相似文献
13.
The exogenous introduction of a molecular species mixture of bovine cortex phosphatidylserine (BC-PS) has been claimed to improve memory function in subjects suffering from age-associated memory impairment and dementia. However, it has been also reported that oral administration of another molecular species mixture of transphosphatidylated-soybean phosphatidylserine (T-Soy-PS) showed a little effect in older individuals with memory complaints. In this study, a new type of mixture of transphosphatidylated-fish liver phosphatidylserine (T-FL-PS) species, as well as intact molecular species of the two commercial products of T-Soy-PS made in the United States and Europe, were characterized by mass spectrometry and tandem mass spectrometry, and molecular species of various transphosphatidylated PSs, including T-FL-PS, T-Soy-PS and transphosphatidylated-squid skin phosphatidylserine (T-SS-PS) were then compared with those of BC-PS for the first time. The results show that (i) the presence of a relatively high content of docosahexaenoic acid (DHA)-containing species (more than 45%) is remarkable in T-FL-PS, (ii) DHA-ether PS species are found only in T-FL-PS, especially the species (about 17%) made from marine fish liver, rather than BC-PS and T-SS-PS, and (iii) DHA species present in both T-FL-PS and T-SS-PS are significantly enriched, compared with those in BC-PS (about 10%) and T-Soy-PS (no DHA species). We conclude that mixtures of T-FL-PS and T-SS-PS species are considered to be qualified alternatives of BC-PS supplement used as brain nutrients. It is expected that intact structural information on molecular species in current and potential transphosphatidylated PS products provided here will be useful in the further study and development of therapeutic roles of the phospholipid at molecular species level. 相似文献
14.
The GlnK and GlnB proteins are members of the pII signal transduction protein family, which is essential in nitrogen regulation due to this protein family's ability to sense internal cellular ammonium levels and control cellular response. The role of GlnK in nitrogen regulation has been studied in a variety of bacteria but previously has been uncharacterized in the purple nonsulfur anoxygenic phototropic bacterium Rhodopseudomonas palustris. R. palustris has tremendous metabolic versatility in its modes of energy generation and carbon metabolism, and it employs a sensitive nitrogen-ammonium regulation system that may vary from that of other commonly studied bacteria. In R. palustris, there are three annotated forms of pII proteins: GlnK1, GlnK2, and GlnB. Here we describe, for the first time, the characterization of GlnK1, GlnK2, and GlnB modifications as a response to nitrogen availability, thereby providing information about how this bacterium regulates the AmtB ammonium transporter and glutamine synthetase, which controls the rate of glutamate to glutamine conversion. Using a strategy of creating C-terminally tagged GlnK and GlnB proteins followed by tandem affinity purification in combination with top-down mass spectrometry, four isoforms of the GlnK2 and GlnB proteins and two isoforms of the GlnK1 protein were characterized at high resolution and mass accuracy. Wild-type or endogenous expression of all three proteins was also examined under normal ammonium conditions and ammonium starvation to ensure that the tagging and affinity purification methods employed did not alter the natural state of the proteins. All three proteins were found to undergo uridylylation under ammonium starvation conditions, presumably to regulate the AmtB ammonium transporter and glutamine synthetase. Under high-ammonium conditions, the GlnK1, GlnK2, and GlnB proteins are unmodified. This experimental protocol involving high-resolution mass spectrometry measurements of intact proteins provides a powerful method of examining the posttranslational modifications that play a crucial role in both the regulation of the AmtB ammonium transporter and glutamine synthetase within R. palustris. 相似文献
15.
Interassay variation of antibody-based routine tests hampers comparability of measurement results for growth hormone (GH) between different laboratories and decision making in clinical practice. Here it is demonstrated that quantification of GH by isotope dilution mass spectrometry (IDMS) constitutes a way to obtain precise and reliable results that can be referred to in evaluation of performance of commercial test kits. With the IDMS method developed, tryptic cleavage products YSFLQNPQTSLCFSESIPTPSNR (T6) and LEDGSPR (T12) of GH are quantified by liquid chromatography tandem mass spectrometry (LC-MS/MS) using isotopically labeled forms of the peptides as internal standards. The GH cleavage fragments are obtained by whole serum tryptic proteolysis and then extracted from the resulting mixture by semipreparative reversed-phase LC followed by strong cation exchange chromatography. Analysis of blank serum spiked with recombinant 22-kDa GH at different concentration levels would result in a mean recovery of 101.6%, a standard deviation (SD) of 2.5%, a combined uncertainty (uc) of 3.0%, and a limit of quantification (LOQ) of 1.7 μg/L when quantifying T6 as a GH-derived fragment, whereas recovery = 100.7%, SD = 2.4%, uc = 2.5%, and LOQ = 2.7 μg/L were found with T12. The potential to acquisition of reference values is exemplified by application to serum materials used in a recent quality assessment exercise for routine laboratories. 相似文献
16.
《Bioscience, biotechnology, and biochemistry》2013,77(8):2184-2190
A sensitive and simple liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed for the detection of alginate oligosaccharides (AOs) in mouse plasma and urine after oral administration. In an AO mixture, dimer, trimer, and tetramer were detected by LC-MS/MS equipped with an anion-exchange column with extremely high sensitivity. By this method, we detected certain levels of AOs in samples prepared from mouse plasma and urine after a single oral administration of the AO mixture. Based on a calibration curve made with an AO trimer peak area as a standard, the maximum plasma and urine concentrations of AOs were estimated to be 24.5 μg/ml at 5 min and 425.5 μg/ml at 30 min, respectively. These results suggest that the LC-MS/MS method is well suited to pharmacokinetic analysis of AOs in an in vivo system, and that some of orally administered AOs, at least from dimer to tetramer, are absorbed by digestive organs promptly, and that unaltered, these oligomers were excreted into an urine after a single oral administration to a mouse. 相似文献
17.
Shiori Nakazawa Joomi Ahn Noritaka Hashii Kenji Hirose Nana Kawasaki 《Biochimica et Biophysica Acta - Proteins and Proteomics》2013,1834(6):1210-1214
Human insulin and insulin lispro (lispro), a rapid-acting insulin analog, have identical primary structures, except for the transposition of a pair of amino acids. This mutation results in alterations in their higher order structures, with lispro dissociating more easily than human insulin. In our previous study performed using hydrogen/deuterium exchange mass spectrometry (HDX/MS), differences were observed in the rates and levels of deuteration among insulin analog products, which were found to be related to their self-association stability. In this study, we carried out peptide mapping of deuterated human insulin and lispro to determine the regions responsible for these deuteration differences and to elucidate the type of structural changes that affect their HDX reactivity. We identified A3–6 and B22–24 as the 2 regions that showed distinct differences in the number of deuterium atoms incorporated between human insulin and lispro. These regions contain residues that are thought to participate in hexamerization and dimerization, respectively. We also determined that over time, the differences in deuteration levels decreased in A3–6, whereas they increased in B22–24, suggesting a difference in the dynamics between these 2 regions. This article is part of a Special Issue entitled: Mass spectrometry in structural biology. 相似文献
18.
Guo J Yang EC Desouza L Diehl G Rodrigues MJ Romaschin AD Colgan TJ Siu KW 《Proteomics》2005,5(7):1953-1966
Surface-enhanced laser desorption/ionization-mass spectrometry (SELDI-MS) has conventionally been practiced on linear time of flight (TOF) which has low mass accuracy and resolution. Here we demonstrate in an examination of both malignant and nonmalignant endometrial tissue homogenates that high mass accuracy and resolution in the MS stage are crucial. Using a commercially available quadrupole/TOF (QqTOF), we were able to resolve two potential cancer markers, subsequently identified off-line as chaperonin 10 and calgranulin A, that differ by 8 Da in mass. Two off-line protein identification protocols were developed: the first was based on size-exclusion chromatography (SEC), sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), protein extraction, trypsin digestion, and matrix-assisted laser desorption/ionization-tandem MS (MALDI-MS/MS); the second on SEC and shotgun nano-liquid chromatography (nanoLC)-MS/MS. Analyses on a cohort of 44 endometrial homogenates showed 22 out of 23 nonmalignant samples had nondetectable to very low abundance of chaperonin 10 and calgranulin A; 17 of the 21 malignant samples had detectable to abundant levels of both proteins. Immunohistochemical staining of a tissue microarray of 32 samples showed that approximately half of malignant endometrial tissues exhibited positive staining for calgranulin A in the malignant epithelium, while 9 out of 10 benign tissues exhibited negative epithelial staining. In addition, macrophages/granulocytes in malignant as well as nonmalignant tissues showed positive staining. No immunostaining occurred in stroma or myometrium. Calgranulin A, in combination with chaperonin 10 and other proteins, may eventually constitute a panel of markers to permit diagnosis and screening of endometrial cancer. 相似文献
19.
Janković M 《Comparative biochemistry and physiology. Toxicology & pharmacology : CBP》2002,133(3):369-374
A preparation of polyclonal antibodies to human placental calcium-dependent, carbohydrate-binding glycoprotein, previously identified as wheat germ agglutinin-immunoreactive protein, was applied as the ligand in an immunoaffinity procedure. Following electrophoretic separation of purified material, the specific 66-kDa antigen band was excised and subjected to in-gel protein cleavage. Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) analysis of the tryptic digest yielded 42 isotopically resolved peptide fragments from mass 860 to 2,690. Empirical data from MALDI-MS were analyzed by computer assistance using ProteoMetrics PROFOUND software. Protein candidates reported in the specified identification database search are discussed in relation to the biochemical characteristics of the protein analyzed and its possible antigenic relatedness to wheat germ agglutinin. We speculate that a fibulin-like member of the epidermal growth factor-repeat protein family might be selected as a positive match. 相似文献
20.
《Bioscience, biotechnology, and biochemistry》2013,77(8):1506-1510
β-Glucuronidase and sulfatase are the major deconjugating enzymes used in the cleavage of the glucuronate and sulfate moieties, respectively, from certain conjugated food factors including polyphenols. In the present study, we found that compounds having the same molecular weights as catechins were present in Helix pomatia- and/or Abalone entrails-derived β-glucuronidase and sulfatase by liquid chromatography tandem mass spectrometry (LC-MS/MS) with multiple reaction monitoring methods. On the other hand, the same molecular weights as catechins were undetectable in Escherichia coli-derived β-glucuronidase and Aerobacter aerogenes-derived sulfatase. By high performance liquid chromatography, enzyme-derived catechins were not detected because of approximately 1,000-fold lower sensitivity as compared to LC-MS/MS. These results suggest that the catechins in these enzymes might be attributed to the diets of the organisms as the enzyme sources. 相似文献