首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
There are some specifics in the presentation of coronary artery disease (CAD) in women compared with men that may cause diagnostic pitfalls. The accuracy of noninvasive diagnostic testing in women tends to be lower than that in men. Stress myocardial perfusion imaging with 99m-Tc sestamibi gated SPECT is an accurate technique for detecting CAD. Only a few studies have compared dipyridamole stress imaging according to gender. The aim of the study was to compare the diagnostic value of dipyridamole myocardial perfusion imaging with 99m-Tc sestamibi gated SPECT in detecting CAD among patients of both sexes. We studied 62 consecutive patients (38 men, 24 women) using 99m-Tc sestamibi gated SPECT and dipyridamole stress to detect CAD. All the patients also underwent coronary angiography. Overall regional sensitivity was significantly lower in women compared with men (71.4% vs. 92.7%, p=0.039). There were no significant differences for detecting CAD in individual coronary arteries, although regional sensitivity in all three vascular territories was higher in men compared to women. The lowest sensitivity in women was found in the LAD territory (66.6%). Overall regional specificity in men and women was similar and did not reach statistical significance (88.7% vs. 94.7%). Significantly lower specificity in men was found only in the RCA territory (79.1%), compared with that in women (100%). Our results confirmed that there are certain gender differences in the diagnostic performance of dipyridamole stress myocardial perfusion imaging with 99-Tc sestamibi gated SPECT which are assigned to the characteristics of the female population. However, the diagnostic accuracy is also quite high in women, which makes this technique efficient enough in detecting CAD among this population.  相似文献   

2.
The generally accepted indications for stress testing in patients with coronary artery disease include confirming the diagnosis of angina, determining the limitation of activity caused by angina, assessing prognosis in patients with known coronary artery disease, assessing perioperative risk, and evaluating responses to therapy. In patients with a clinical scenario strongly suggestive of angina, testing is not necessary to diagnose coronary artery disease. The exercise treadmill-electrocardiogram test is the oldest and most extensively used stress test and can be reliably performed in patients who are clinically stable and who have an interpretable resting electrocardiogram. The addition of myocardial imaging agents such as thallium 201, technetium Tc 99m sestamibi, and technetium Tc 99m teboroxime increases the sensitivity and specificity for detecting coronary disease. Pharmacologic agents such as dipyridamole, adenosine, and dobutamine may be used in patients who cannot exercise adequately. Myocardial ischemia can also be evaluated by echocardiography, computed tomography, or magnetic resonance imaging, especially when additional information such as left ventricular and valvular function is desired. We review the indications for the noninvasive evaluation of coronary artery disease and the rationale for selecting a diagnostic test.  相似文献   

3.

Purpose

Chronic hand and wrist pain is a common clinical issue for orthopaedic surgeons and rheumatologists. The purpose of this study was 1. To analyze the interobserver agreement of SPECT/CT, MRI, CT, bone scan and plain radiographs in patients with non-specific pain of the hand and wrist, and 2. to assess the diagnostic accuracy of these imaging methods in this selected patient population.

Materials and Methods

Thirty-two consecutive patients with non-specific pain of the hand or wrist were evaluated retrospectively. All patients had been imaged by plain radiographs, planar early-phase imaging (bone scan), late-phase imaging (SPECT/CT including bone scan and CT), and MRI. Two experienced and two inexperienced readers analyzed the images with a standardized read-out protocol. Reading criteria were lesion detection and localisation, type and etiology of the underlying pathology. Diagnostic accuracy and interobserver agreement were determined for all readers and imaging modalities.

Results

The most accurate modality for experienced readers was SPECT/CT (accuracy 77%), followed by MRI (56%). The best performing, though little accurate modality for inexperienced readers was also SPECT/CT (44%), followed by MRI and bone scan (38% each). The interobserver agreement of experienced readers was generally high in SPECT/CT concerning lesion detection (kappa 0.93, MRI 0.72), localisation (kappa 0.91, MRI 0.75) and etiology (kappa 0.85, MRI 0.74), while MRI yielded better results on typification of lesions (kappa 0.75, SPECT/CT 0.69). There was poor agreement between experienced and inexperienced readers in SPECT/CT and MRI.

Conclusions

SPECT/CT proved to be the most helpful imaging modality in patients with non-specific wrist pain. The method was found reliable, providing high interobserver agreement, being outperformed by MRI only concerning the typification of lesions. We believe it is beneficial to integrate SPECT/CT into the diagnostic imaging algorithm of chronic wrist pain.  相似文献   

4.
An important aspect of the diagnostic and prognostic work-up of patients with ischaemic cardiomyopathy is the assessment of myocardial viability. Patients with left ventricular dysfunction who have viable myocardium are the patients at highest risk because of the potential for ischaemia but at the same time benefit most from revascularisation. It is important to identify viable myocardium in these patients, and radionuclide myocardial scintigraphy is an excellent tool for this. Single-photon emission computed tomography perfusion scintigraphy (SPECT), whether using 201thallium, 99mTc-sestamibi, or 99mTc- tetrofosmin, in stress and/or rest protocols, has consistently been shown to be an effective modality for identifying myocardial viability and guiding appropriate management.Metabolic and perfusion imaging with positron emission tomography radiotracers frequently adds additional information and is a powerful tool for predicting which patients will have an improved outcome from revascularisation. New techniques in the nuclear cardiology field, such as attenuation corrected SPECT, dual isotope simultaneous acquisition (DISA) SPECT and gated FDG PET are promising and will further improve the detection of myocardial viability. Also the combination of multislice computed tomography scanners with PET opens possibilities of adding coronary calcium scoring and noninvasive coronary angiography to myocardial perfusion imaging and quantification.  相似文献   

5.
In patient with primary hyperparathyroidism, preoperative imaging first objective is to determine accurately and reliably position and anatomic localization of enlarged parathyroid gland in order to guide surgeon for gland removal and to permit minimally invasive surgery. Although subtraction planar scintigraphy is an efficient imaging to diagnose hyperfunctioning parathyroid, the lack of anatomical reference for this single imaging technique could be obviated by hybrid imaging. We compared, in 23 patients with primary hyperparathyroidism, a planar scan of neck and mediastinum associated with a cervical anterior pinhole scan to a subtraction (123I/99mTc-MIBI) SPECT scan of neck and mediastinum fused with CT. Surgical and histopathologic findings were used as the standard of truth. Subtraction SPECT/CT appeared to be more sensitive and specific than planar protocol to diagnose and to accurately localize pathologic parathyroid. Sensitivity was 76 and 56 %, specificity was 100 and 80 % for hybrid SPECT/CT and planar protocol respectively. SPECT protocol was typically more efficient to diagnose pathologic parathyroid derived from upper gland and for patient with concomitant nodular goiter.  相似文献   

6.
IntroductionIn preclinical research, the growing number of transgenic models has led to the need for renal-function studies in mice. Many efforts have been made to develop dedicated SPECT systems for rodents, but their availability is limited due to high capital costs. The aim of this work is to demonstrate the feasibility of mouse renal imaging by using an inexpensive alternative based on clinical gamma-cameras.MethodsA healthy mouse was scanned 3 h after injection of 6 mCi of Dimercaptosuccinic acid (DMSA) labeled with 99mTc by using a single-head gamma-camera in conjunction with a dedicated pinhole collimator. List-mode data were binned to emulate multiple injections of 1 mCi, 0.1 mCi and 0.01 mCi of 99mTc-DMSA and 6-min ventral and dorsal planar images were acquired and SPECT imaging (60 projection images acquired over 60 min) was performed. An optimization of the protocols in terms of injected activity, time scan, renal cortex uniformity and cortex-to-pelvis contrast was carried out.ResultsThe appropriate protocols were an injected activity of 0.6 mCi, combined with duration of scanning of 1 min for planar and 60 min for SPECT imaging. Our results were validated through the relative quantification of renal function, which showed that both kidneys contributed equally to the total function. They showed that functional structures of the mouse kidneys can be visually distinguished as easily as in human studies.ConclusionsOur findings showed the feasibility of conducting quantitative DMSA SPECT studies of anesthetized mice on clinical gamma cameras.  相似文献   

7.
Background99mTc sestamibi scanning and aspiration biopsy can predict the histopathological result of a thyroid nodule fairly accurately.ObjectiveTo determine the accuracy of 99mTc sestamibi scanning in detecting malignancy in patients with thyroid nodule confirmed by definitive histopathological report after thyroidectomy.Material and methodsA total of 69 patients with a solitary thyroid nodule were studied. In all patients, fine needle aspiration, total thyroidectomy for suspected thyroid cancer, and histological analysis of the surgical specimen were performed. There were 54 patients with a positive 99mTc sestamibi scan; of these, malignancy was confirmed by histological analysis in 25 and excluded in 29. There were 15 patients with a negative 99mTc sestamibi scan; of these, three had a final diagnosis of cancer and 12 were confirmed as cancer-free.ResultsThe diagnostic accuracy of 99mTc sestamibi scanning in detecting malignancy in thyroid nodules was determined through a statistical analysis. 99mTc sestamibi scan for thyroid cancer had a sensitivity of 89.28% and a specificity of 29.25%. The positive predictive value was 46.29% and the negative predictive value was 80%.ConclusionsWe believe that 99mTc sestamibi scan should be routinely used in all patients with a thyroid nodule and an indeterminate result on fine needle aspiration. This procedure is most useful in excluding malignancy in patients with a negative 99mTc sestamibi scan.  相似文献   

8.
《Endocrine practice》2008,14(1):28-32
ObjectiveTo examine whether surgeon-performed ultrasonography (SPU) in patients with primary hyperparathyroidism and negative preoperative sestamibi scans improves adenoma localization, increases the directed unilateral exploration rate, and reduces operative time and length of hospital stay.MethodsWe retrospectively analyzed 100 consecutive patients with primary hyperparathyroidism encountered between January 1, 2005, and March 31, 2007. Patients underwent preoperative sestamibi scanning and SPU. Minimally invasive radio-guided parathyroidectomy (MIRP) was performed on patients with positive sestamibi scans. In sestamibi scan–negative patients, unilateral exploration was performed with removal of the adenoma, which was submitted for frozen section. Accuracy, operative time, hospital length of stay, mortality, and morbidity were assessed.ResultsOf 100 patients, 79 had positive sestamibi scans and underwent MIRP. Twenty-one had negative sestamibi scans, 18 of whom underwent SPU. Parathyroid adenoma was localized in 17 (94%) of the 18 patients. Operative time and length of hospital stay were not significantly different between sestamibi scan–negative patients who underwent SPU with directed unilateral exploration and sestamibi scan–positive patients who underwent MIRP (operative time: 46 minutes vs 38 minutes, respectively; length of hospital stay: 17.8 hours vs 16.1 hours, respectively). Operative time and length of hospital stay were significantly shorter in sestamibi scan–negative patients who underwent SPU with directed unilateral exploration and in patients who underwent MIRP than in historical controls who underwent 4-gland exploration (P < .01 for both outcomes). No morbidity or mortality was documented.ConclusionSPU localizes 94% of adenomas in sestamibi scan–negative patients, which allows for directed unilateral exploration and results in operative time and length of hospital stay not significantly different from patients undergoing MIRP. (Endocr Pract. 2008;14:28-32)  相似文献   

9.
IntroductionSingle photon emission computed tomography combined with a low dose computed tomography (SPECT/CT), is a hybrid imaging integrating functional and anatomical data. The purpose of our study was to evaluate the contribution of the SPECT/CT over traditional planar imaging of patients with differentiated thyroid carcinoma (DTC).MethodsPost-therapy iodine 131 (131I) whole-body scan followed by cervico-thoracic SPECT/CT, were performed in 100 patients with DTC.ResultsAmong these 100 patients followed for a predominantly papillary DTC, planar imaging and SPECT/CT, were perfectly concordant in 70% of patients and discordant in the remaining 30%. The use of fusion imaging SPECT/CT compared to conventional planar imaging allowed us to correct our therapeutic approach in 27% (27/100 patients), according to the protocols of therapeutic management of our institute.ConclusionSPECT/CT is a hybrid imaging modality which provides better identification and more correct anatomic localization of the foci of radioiodine uptake with impact on therapeutic management.  相似文献   

10.
Cardiac positron emission tomography (PET) is yet considered as a reference imaging technique but remains poorly used in clinical practice. At the present time, the advantages of cardiac PET investigations are far to be evident, when compared with conventional tomoscintigraphy (SPECT), except for perfusion imaging in the obese and for viability assessment in case of very severe cardiac dysfunction. However, this situation might quickly move because of an enhanced availability of PET imaging, dramatic technical progresses and promising new tracers. In particular, the last-generation PET-cameras allow reaching spatial resolutions and detection sensitivities, which are now spectacularly higher than those from conventional SPECT imaging. In addition, the list mode recording allows the subsequent images reconstruction to be synchronized to cardiac cycle but also to respiratory cycle; and the quantifications of myocardial perfusion flow and of coronary flow reserve are now available in clinical routine. Furthermore, new tracers labelled with fluorine-18 are under development, especially for perfusion investigations, and kinetics properties of these new tracers are dramatically enhanced when compared with current perfusion SPECT tracers.  相似文献   

11.
Small cell lung cancer (SCC) has the most rapid growth rate of the four cell types and metastasizes early. Present imaging modalities for staging include chest x-ray, CT, MRI and bone scans. In this preliminary study, we assessed the clinical role of 99mTc-monoclonal antibody (MOAB) scintigraphy in five patients with histologically proven SCC. Each patient was infused with 20–30 mCi of 99mTc labeled Fab fragment of MOAB (NR-LU-10, NeoRx, Seattle, Wash.). Total body simultaneous anterior and posterior images were obtained 14–16 h post injection. SPECT images of the chest were obtained through a 360 ° rotation of the gamma camera and recorded on a 62 × 64 × 16 matrix. Images (1.2cm thick) were generated in transaxial, sagittal and coronal views.Fourteen of fifteen chest lesions detected by CT were confirmed by 99mTc MOAB scintigraphy. Scintigraphy detected one additional chest lesion not seen by CT. Scintigraphy failed to detect a brain lesion (2 cm), a chest lesion, and two adrenal lesions, all of which were seen by CT. In one patient with multiple (more than 10) lesions in the liver, both scintigraphy and CT detected all lesions. Three spine lesions seen on 99mTc MDP scan and positive for metastasis on MRI concentrated 99mTc MOAB, but two rib lesions seen on 99mTc MDP bone scan did not concentrate 99mTc MOAB. It is concluded from these preliminary results that the potential usefulness of 99mTc MOAB scintigraphy as a complementary imaging modality in the staging of small cell lung cancer should be investigated further.  相似文献   

12.
《Endocrine practice》2019,25(1):16-22
Objective: To evaluate the relationship between various biochemical parameters in patients with primary hyperparathyroidism (PHPT) with positive and negative technetium-99 sestamibi (Tc) parathyroid scans performed with single-photon emission computed tomography/computed tomography (SPECT/CT).Methods: This retrospective analysis was used to develop a logistic probability model. It included 218 patients with PHPT. The main outcome measures were serum total calcium, ionized calcium, intact parathyroid hormone (PTH), albumin, alkaline phosphatase, phosphate, 25-hydroxy vitamin D, 1,25-dihydroxy vitamin D, 24-h urinary calcium levels, and parathyroid adenoma weight.Results: Individually, using cut-off levels of 6.0 mg/dL for ionized calcium, 3.0 mg/dL for phosphate, and 90 pg/mL for intact PTH, we found that 91.3% (P = .005), 70.7% (P = .004) and 87.90% (P = .023) of the patients had a positive Tc scan with their corresponding strengths of associations in the parentheses. Similar significant associations were sustained in multivariate setting for serum ionized calcium (P = .015), phosphate (P = .016), and intact PTH (P = .028). A logistic probability model was designed to predict the probability of being positive for Tc scan given a set of covariates.Conclusion: There are significant associations between the levels of serum ionized calcium, phosphate, intact PTH, and Tc scan positivity. Further studies with larger patient populations are needed.Abbreviations: BMI = body mass index; CT = computed tomography; CV = coefficient variation; DXA = dual-energy x-ray absorptiometry; MRI = magnetic resonance imaging; PHPT = primary hyperparathyroidism; PPV = positive predictive value; PTH = parathyroid hormone; SPECT = single-photon emission computed tomography; Tc = technetium-99 sestamibi  相似文献   

13.
Objectives To measure the effectiveness and cost effectiveness of providing care in a chest pain observation unit compared with routine care for patients with acute, undifferentiated chest pain.Design Cluster randomised controlled trial, with 442 days randomised to the chest pain observation unit or routine care, and cost effectiveness analysis from a health service costing perspective.Setting The emergency department at the Northern General Hospital, Sheffield, United Kingdom.Participants 972 patients with acute, undifferentiated chest pain (479 attending on days when care was delivered in the chest pain observation unit, 493 on days of routine care) followed up until six months after initial attendance.Main outcome measures The proportion of participants admitted to hospital, the proportion with acute coronary syndrome sent home inappropriately, major adverse cardiac events over six months, health utility, hospital reattendance and readmission, and costs per patient to the health service.Results Use of a chest pain observation unit reduced the proportion of patients admitted from 54% to 37% (difference 17%, odds ratio 0.50, 95% confidence interval 0.39 to 0.65, P < 0.001) and the proportion discharged with acute coronary syndrome from 14% to 6% (8%, -7% to 23%, P = 0.264). Rates of cardiac event were unchanged. Care in the chest pain observation unit was associated with improved health utility during follow up (0.0137 quality adjusted life years gained, 95% confidence interval 0.0030 to 0.0254, P = 0.022) and a saving of £78 per patient (-£56 to £210, P = 0.252).Conclusions Care in a chest pain observation unit can improve outcomes and may reduce costs to the health service. It seems to be more effective and more cost effective than routine care.  相似文献   

14.
Cold tolerance in plants is an ecologically important trait that has been under intensive study for basic and applied reasons. Determining the fitness benefits and costs of cold tolerance has previously been difficult because cold tolerance is normally an induced trait that is not expressed in warm environments. The recent creation of transgenic plants constitutively expressing cold tolerance genes enables the investigation of the fitness consequences of cold tolerance in multiple temperature environments. We studied three genes from the CBF (C-repeat/dehydration responsive element binding factor) cold tolerance pathway, CBF1, 2 and 3, in Arabidopsis thaliana to test for benefits and costs of constitutive cold tolerance. We used multiple insertion lines for each transgene and grew the lines in cold and control conditions. Costs of cold tolerance, as determined by fruit number, varied by individual transgene. CBF2 and 3 overexpressers showed costs of cold tolerance, and no fitness benefits, in both environments. CBF1 overexpressing plants showed no fitness cost of cold tolerance in the control environment and showed a marginal fitness benefit in the cold environment. These results suggest that constitutive expression of traits that are normally induced in response to environmental stress will not always lead to costs in the absence of that stress, and that the ecological risks of CBF transgene escape should be assessed prior to their use in commercial agriculture.  相似文献   

15.
The feasibility of blood-pool pinhole ECG gated SPECT was investigated in healthy mice to assess right and left ventricular function analysis. Anaesthetized (isoflurane 1-1.5%) adult CD1 mice (n=11) were analyzed after intravenous administration of 0.2 ml of 550 MBq of (99m)Tc human albumin. For blood-pool gated SPECT imaging, 48 ventral step and shoot projections with eight time bins per RR over 180 degrees with 64x64 word images were acquired with a small animal gamma camera equipped with a pinhole collimator of 12 cm in focal length and 1.5 mm in diameter. For appropriate segmentation of right and left ventricular volumes, a 4D Fourier analysis was performed after reconstruction and reorientation of blood-pool images with a voxel size of 0.55x0.55x0.55 mm(3). Average right and left ejection fractions were respectively 52+/-4.7% and 65+/-5.2%. Right end diastolic and end systolic volumes were significantly higher compared with the corresponding left ventricular volumes (P<0.0001 each). A linear correlation between right and left stroke volumes (r=0.9, P<0.0001) was obtained and right and left cardiac outputs were not significantly different 14.2+/-1.9 and 14.1+/-2 ml/min, respectively. To cite this article: C. Goetz et al., C. R. Biologies 331 (2008).  相似文献   

16.

Background  

Parkinson's disease (PD) is the second most common neurodegenerative disorder. One of the most widely used techniques to diagnose PD is a Single Photon Emission Computer Tomography (SPECT) scan to visualise the integrity of the dopaminergic pathways in the brain. Despite this there remains some discussion on the value of SPECT in the differential diagnosis of PD. We did a meta-analysis of all the existing literature on the diagnostic accuracy of both pre- and post-synaptic SPECT imaging in the differential diagnosis of PD.  相似文献   

17.
目的:探讨用单光子发射型计算机断层(single photon emission computedtomography,SPECT)心肌灌注显像,评估心肌梗死(AMI)经冠脉介入治疗(PCI)后的心肌灌注疗效。方法:采用99mTc-tetrofosmin(P53)SPECT心肌灌注显像对54例行PCI治疗的AMI患者评估心肌灌注情况,并追踪记录6个月内心脏事件发生率。结果:SPECT显示无复流组22例,有复流组32例,两组心肌梗死患者近期预后差异有统计学意义(P<0.05)。无复流组不良事件发生率较有复流组有增加趋势;另外,急诊PCI组的预后明显好于择期PCI组,差异有统计学意义(P<0.05)。结论:SPECT心肌灌注显像可对AMI患者梗死相关血管(IRA)再通治疗疗效进行可靠的无创性评价。  相似文献   

18.
BackgroundAbnormal cardiac uptake of 123I-metaiodobenzylguanidine (123I-MIBG) is a diagnostic marker of Lewy body diseases (LBDs), e.g., Parkinson’s disease (PD) and dementia with Lewy bodies (DLB). Planar imaging is generally used to assess cardiac sympathetic dysfunction in 123I-MIBG scintigraphy; however, its clinical utility requires further improvement. We hypothesized that the co-registration of single-photon emission tomography (SPECT) and computed tomography (CT) images would improve the diagnostic accuracy of 123I-MIBG cardiac scintigraphy for LBDs. This study sought to evaluate the effects of SPECT/CT imaging on 123I-MIBG cardiac scintigraphy for diagnosing LBDs.MethodsWe retrospectively investigated data of 54 patients (consecutive 18 patients in each PD, DLB, and idiopathic normal pressure hydrocephalus [iNPH] groups) who underwent 123I-MIBG cardiac scintigraphy (planar and SPECT/CT) because of suspected LBDs at the Tohoku University hospital from June 2012 to June 2015. We compared the diagnostic accuracies of the conventional planar 123I-MIBG method and SPECT/CT methods (manual and semi-automatic).ResultsIn the conventional planar analysis, 123I-MIBG uptake decreased only in the DLB group compared with the iNPH group. In contrast, the SPECT/CT analysis revealed significantly lower 123I-MIBG uptake in both the PD and DLB groups compared with the iNPH group. Furthermore, a receiver operating characteristic analysis revealed that both the manual and semi-automatic SPECT/CT methods were superior to the conventional planar method in differentiating the 3 disorders.ConclusionsSPECT/CT 123I-MIBG cardiac scintigraphy can detect mild cardiac sympathetic dysfunction in LDBs. Our results suggest that the SPECT/CT technique improves diagnostic accuracy for LBDs.  相似文献   

19.
Myocardial perfusion SPECT is a routine for the assessment of patients with coronary artery disease (CAD). However, attenuation artifacts may decrease the specificity of the test. These artifacts can be corrected with an attenuation correction. We prospectively included 70 patients who underwent myocardial perfusion SPECT with (IRAC) and without (IRNC) attenuation correction using transmission CT imaging integrated in the acquisition system in patients with low prevalence of CAD. Automatic quantitative analysis with summed stress score (SSS) and rest (SRS) and summed difference score (SDS) was used as interpretation criteria. The results showed a specificity of 80% for IRAC and 56% for IRNC, a positive predictive value of 40% for IRAC and 23% for IRNC, without any significant change in sensitivity. An unpaired t-test showed no significant difference between the overall population and one where an artifact was corrected for heart rate and breath rate during the acquisition effort, the body mass index, chest and abdomen circumferences, and the ratio of these two parameters. Attenuation correction significantly improves the specificity of myocardial scintigraphy with no significant difference in sensitivity. The majority of corrections were for artifacts from the inferior wall in men. There is no correlation between the anthropomorphic and physiological parameters and the occurrence of an artifact of attenuation corrected with CT data.  相似文献   

20.
Treadmill stress testing is used in assessing the condition of patients with known or suspected heart disease. We did a prospective study to clarify physician ordering and integration of the test. Ordering criteria were always complied with, although most tests were ordered for evaluation of atypical chest pain and only a few for high risk patients with known cardiac dysfunction, indicating a misplaced emphasis on the diagnostic capabilities of the test. Tests in patients with atypical chest pain and stress-induced ischemic changes were always integrated, but in 30 percent of patients with atypical pain and no stress-induced electrocardiographic changes, the tests were not used in patient management. This was often due to the misconception that negative findings on a stress test excluded coronary disease. Physicians should be alerted to this misplaced emphasis and misconception.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号