首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A high-performance liquid chromatogaphic method was developed for determining the concentrations of ticarcillin (TIPC) epimers in human plasma and urine. Samples were prepared for HPLC analysis with a solid-phase extraction method and the concentrations of TIPC epimers were determined using reversed-phase HPLC. The mobile phase was a mixture of 0.005 M phosphate buffer (pH 7.0) and methanol (12:1, v/v) with a flow-rate of 1.0 ml/min. TIPC epimers were detected at 254 nm. Baseline separation of the two epimers was observed for both plasma and urine samples with a detection limit of ca. 1 μg/ml with a S/N ratio of 3. No peaks interfering with either of the TIPC epimers were observed on the HPLC chromatograms for blank plasma and urine. The recovery was more than 80% for both plasma and urine samples. C.V. values for intra- and inter-day variabilities were 0.9–2.1 and 1.1–6.4%, respectively, at concentrations ranging between 5 and 200 μg/ml. The present method was used to determine the concentrations of TIPC epimers in plasma and urine following intravenous injection of TIPC to a human volunteer. It was found that both epimers were actively secreted into urine and that the secretion of TIPC was not stereoselective. Plasma protein binding was also measured, which revealed stereoselective binding of TIPC in human plasma.  相似文献   

2.
A new high-performance liquid chromatographic method with column switching has been developed for the simultaneous determination of metampicillin and its metabolite ampicillin in biological fluids. The plasma, urine and bile samples were injected onto a precolumn packed with LiChrosorb RP-8 (25–40 μm) after simple dilution with an internal standard solution in 0.05 M phosphate buffer (pH 7.0). The polar plasma components were washed out using 0.05 M phosphate buffer (pH 7.0). After valve switching, the concentrated drugs were eluted in the back-flush mode and separated by an Ultracarb 5 ODS-30 column with a gradient system of acetonitrile-0.02 M phosphate buffer (pH 7.0) as the mobile phase. The method showed excellent precision, accuracy and speed with a detection limit of 0.1 μg/ml. The total analysis time per sample was less than 40 min and the coefficients of variation for intra- and inter-assay were less than 5.1%. This method has been successfully applied to plasma, urine and bile samples from rats after intravenous injection of metampicillin.  相似文献   

3.
A method for the simultaneous direct determination of salicylate (SA), its labile, reactive metabolite, salicyl acyl glucuronide (SAG), and two other major metabolites, salicyluric acid and gentisic acid in plasma and urine is described. Isocratic reversed-phase high performance liquid chromatography (HPLC) employed a 15-cm C18 column using methanol-acetonitrile-25 mM acetic acid as the mobile phase, resulting in HPLC analysis time of less than 20 min. Ultraviolet detection at 310 nm permitted analysis of SAG in plasma, but did not provide sensitivity for measurement of salicyl phenol glucuronide. Plasma or urine samples are stabilized immediately upon collection by adjustment of pH to 3–4 to prevent degradation of the labile acyl glucuronide metabolite. Plasma is then deproteinated with acetonitrile, dried and reconstituted for injection, whereas urine samples are simply diluted prior to injection on HPLC. m-Hydroxybenzoic acid served as the internal standard. Recoveries from plasma were greater than 85% for all four compounds over a range of 0.2–20 μg/ml and linearity was observed from 0.1–200 μg/ml and 5–2000 μg/ml for SA in plasma and urine, respectively. The method was validated to 0.2 μg/ml, thus allowing accurate measurement of SA, and three major metabolites in plasma and urine of subjects and small animals administered salicylates. The method is unique by allowing quantitation of reactive SAG in plasma at levels well below 1% that of the parent compound, SA, as is observed in patients administered salicylates.  相似文献   

4.
This study investigated a means of quantifying urinary myoglobin using a novel reverse-phase high-performance liquid chromatography (RP–HPLC) method that is an alternative measure of exercise-induced muscle damage. It also investigated the effect of storage and alkalization on urinary myoglobin stability issues. An RP–HPLC method was validated by precision and repeatability experiments. Myoglobin stability was determined through spiked urine samples stored at various temperatures over an 8-week period using alkalization and dilution in a pH 7.0 buffer. The method was validated with urine collected from mixed martial arts fighters during a competition and training session. The method produced linearity from 5 to 1000 μg/ml (R2 = 0.997), intra- and inter-assay coefficients of variation from 0.32 to 2.94%, and a lower detection limit of 0.2 μg/ml in the final dilution and 2 μg/ml in the original urine sample. Recovery ranged from 96.4 to 102.5%, myoglobin remained stable at 4 °C when diluted in a pH 7.0 buffer after 20 h, and a significant increase (P < 0.01) and an identifiable peak were observed following a mixed martial arts contest and training session. Storage length and conditions had significant effects (P < 0.05) on stability. The method's simplicity and noninvasive nature means it can be used as an alternative muscle damage assay following exercise and trauma.  相似文献   

5.
A rapid, sensitive and specific high-performance liquid chromatographic (HPLC) assay was developed for the determination of amdinocillin (formerly mecillinam) in human plasma and urine. The assay is performed by direct injection of a plasma protein-free supernatant or a dilution of urine. A 10-μm μBondapak phenyl column with an eluting solvent of water—methanol—1 M phosphate buffer, pH 7 (70:30:0.5) was used, with UV detection of the effluent at 220 nm. Azidocillin potassium salt [potassium-6-(d-(-)-α-azidophenyacetamido)-penicillanate] was used as the internal standard and quantitation was based on peak height ratio of amdinocillin to that of the internal standard. The assay has a recovery of 74.4 ± 6.3% (S.D.) in the concentration ranges of 0.1–20 μg per 0.2 ml of plasma with a limit of detection equivalent to 0.5 μg/ml plasma. The urine assay was validated over a concentration range of 0.025–5 mg/ml of urine, and has a limit of detection of 0.025 mg/ml (25 μg/ml) using a 0.1-ml urine specimen per assay.The assay was applied to the determination of plasma and urine concentrations of amdinocillin following intravenous administration of a 10 mg/kg dose of amdinocillin to two human subjects. The HPLC and microbiological assays were shown to correlate well for these samples.  相似文献   

6.
A column-switching high-performance liquid chromatographic method has been developed for the simple and sensitive analysis of BO-2727 (I) in human plasma and urine. Plasma samples were diluted with an equal volume of a stabilizer, and the mixture was directly injected onto the HPLC system. The analyte was enriched in a pre-treatment column, while endogenous components were eluted to waste. The analyte was then backflushed onto an analytical column and quantified with ultraviolet detection. Urinary concentrations were determined in a similar way except that the enriched analyte was eluted in the foreflush mode to a cation-exchange column used for chromatographic separation. The standard curves for the drug were linear in the range of 0.05–50 μg/ml in plasma and 0.5–100 μg/ml in urine. The limits of quantification for plasma and urine were found to be 0.05 μg/ml and 0.5 μg/ml, respectively. This method was used to support Phase I clinical pharmacokinetic studies.  相似文献   

7.
Automated procedures for the determination of CGP 33 101 in plasma and the simultaneous determination of CGP 33 101 and its carboxylic acid metabolite, CGP 47 292, in urine are described. Plasma was diluted with water and urine with a pH 2 buffer prior to extraction. The compounds were automatically extracted on reversed-phase extraction columns and injected onto an HPLC system by the automatic sample preparation with extraction columns (ASPEC) automate. A Supelcosil LC-18 (5 μm) column was used for chromatography. The mobile phase was a mixture of an aqueous solution of potassium dihydrogen phosphate, acetonitrile and methanol for the assay in plasma, and of an aqueous solution of tetrabutylammonium hydrogen sulfate, tripotassium phosphate and phosphoric acid and of acetonitrile for the assay in urine. The compounds were detected at 230 nm. The limit of quantitation was 0.11 μml/l (25 ng/mol) for the assay of CGP 33 101 in plasma, 11 μmol/l (2.5 μg/ml) for its assay in urine and 21 μmol/l (5 μg/ml) for the assay of CGP 47 292 in urine.  相似文献   

8.
A column-switching, reversed-phase high-performance liquid chromatographic (HPLC) method for the determination of a new carbapenem antibiotic assay using ultraviolet detection has been developed for a new carbapenem antibiotic L-749,345 in human plasma and urine. A plasma sample is centrifuged and then injected onto an extraction column using 25 mM phosphate buffer, pH 6.5. After 3 min, using a column-switching valve, the analyte is back-flushed with 10.5% methanol–phosphate buffer for 3 min onto a Hypersil 5 μm C18 BDS 100×4.6 mm analytical column and then detected by absorbance at 300 nm. The sample preparation and HPLC conditions for the urine assay are similar, except for a longer analytical column 150×4.6 mm. The plasma assay is specific and linear from 0.125 to 50 μg/ml; the urine assay is linear from 1.25 to 100 μg/ml.  相似文献   

9.
A simple and sensitive high-performance liquid chromatograhic (HPLC) method for the determination of (+)-(S)-sotalol and (−)-(R)-sotalol in biological fluids was established. Following extraction with isopropyl alcohol from biological samples on a Sep-Pak C18 cartridge, the eluent was derivatized with 2,3,4,6-tetra-O-acetyl-β-d-glucopyranosol isothiocyanate (GITC). The diastereoisomeric derivatives are resolved by HPLC with UV detection at 225 nm. Calibration was linear from 0.022 to 4.41 μg/ml in human plasma and from 0.22 to 88.2 μg/ml in human urine for both (+)-(S)- and (−)-(R)-sotalol. The lower limit of determination was 0.022 μg/ml for plasma and 0.22 μg/ml for urine. The within-day and day-to-day coefficients of variation were less than 7.5% for each enantiomer at 0.09 and 1.8 μg/ml in plasma and at 0.44 and 4.4 μg/ml in urine. The method is also applicable to other biological specimens such as rat, mouse and rabbit plasma.  相似文献   

10.
A high-performance liquid chromatographic (HPLC) method with ultraviolet (UV) absorbance was developed for the analysis of piperacillin-tazobactam (tazocillin), in plasma and urine. The detection was performed at 218 nm for tazobactam and 222 nm for piperacillin. The procedure for assay of these two compounds in plasma and of piperacillin in urine involves the addition of an internal standard (ceftazidime for tazobactam and benzylpenicillin for piperacillin) followed by a treatment of the samples with acetonitrile and chloroform. To quantify tazobactam in urine, diluted samples were analysed using a column-switching technique without internal standard. The HPLC column, LiChrosorb RP-select B, was equilibrated with an eluent mixture composed of acetonitrile-ammonium acetate (pH 5). The proposed technique is reproducible, selective, and reliable. The method has been validated, and stability tests under various conditions have been performed. Linear detector responses were observed for the calibration curve standards in the ranges 5–60 μg/ml for tazobactam, and 1–100 μg/ml for piperacillin and spans what is currently though to be the clinically relevant range for tazocillin concentrations in body fluids. The limit of quantification was 3 μg/ml for tazobactam and 0.5 μg/ml for piperacillin in plasma and urine. Extraction recoveries from plasma proved to be more than 85%. Precision, expressed as C.V., was in the range 0.4–18%.  相似文献   

11.
We have developed and validated a sensitive and selective assay for the quantification of paclitaxel and its metabolites 6α,3′-p-dihydroxypaclitaxel, 3′-p-hydroxypaclitaxel and 6α-hydroxypaclitaxel in plasma, tissue, urine and faeces specimens of mice. Tissue and faeces were homogenized (approximately 0.1–0.2 g/ml) in bovine serum albumin (40 g/I) in water, and urine was diluted (1:5, v/v) in blank human plasma. Sample pretreatment involved liquid-liquid extraction of 200–1000 μl of sample with diethyl ether followed by automated solid-phase extraction using cyano Bond Elut column. 2′-Methylpaclitaxel was used as internal standard. The overall recovery of the sample pretreatment procedure ranged from 76 ot 85%. In plasma, the lower limit of detection (LOD) and the lower limit of quantitation (LLQ) are 15 and 25 ng/ml, respectively, using 200 μl of sample. In tissues, faeces and urine the LLQs are 25–100 ng/g, 125 ng/g and 25 ng/ml, respectively, using 1000 μl (faeces: 200 μl) of homogenized or diluted sample. The concentrations in the various biological matrices, for validation procedures spiked with known amounts of the test compounds, are read from calibration curves constructed in blank human plasma in the range 25–100 000 ng/ml for paclitaxel and 25–500 ng/ml for the metabolites. The accuracy and precision of the assay fall within the generally accepted criteria for bio-analytical assays.  相似文献   

12.
A fast, simple, and cost-effective HPLC method for the quantitation of the antiviral drug ganciclovir is described. The serum samples are extracted with perchloric acid and neutralized with potassium phosphate buffer, and urine samples are diluted with distilled water. A reversed-phase column with isocratic elution by 15 mM potassium phosphate buffer (pH 2.5) containing 0.25% acetonitrile is used to separate ganciclovir; quantitation is by UV absorbance at 254 nm. Total turnaround time is 22 min; more than 3000 samples can be run on a single column without loss of peak quality. The limit of quantitation is 0.05 μg/ml. Recoveries varied from 91 to 10% with coefficients of variation ranging from 0.387 to 7.95%.  相似文献   

13.
A method for the quantitative determination of iothalamate (IOT) in rat urine, plasma and tubular fluid by capillary zone electrophoresis (CE) has been developed and validated. Samples of urine and tubular fluids were diluted with water and samples of plasma were deproteinized with two volumes of acetonitrile containing the internal standard, p-aminobenzoic acid (PABA). A BioFocus 2000 system (Bio-Rad, Hercules, CA, USA) was used. The UV detector was set at 254 nm. The samples were loaded into uncoated fused-silica capillary (40 cm×50 μm) by pressure injection. A borate buffer [20 mM, pH 12 (pH adjusted with 1.0 M NaOH)] was used as the electrophoretic buffer. The typical analytical conditions were: voltage, 22 kV; injection, 9 psi×s; capillary and carousel temperatures were 20°C and 18°C respectively. The linear relationship was observed between time-corrected peak area of IOT in water and urine or the corrected peak area ratio of IOT to PABA in plasma and the nominal concentration of IOT with correlation coefficient greater than 0.999. The intra- and inter-day coefficients of variation (CV) were less than 8%. The concentration of IOT in plasma, urine and tubular fluid determined by CE can be used for estimation of whole kidney and single nephron clearances.  相似文献   

14.
A rapid, sensitive and specific normal-phase (adsorption) high-performance liquid chromatographic (HPLC) assay was developed for the determination of 1-(2-aminoethyl)-3-(2,6-dichlorophenyl)thiourea [I] in plasma and urine. The assay involves the extraction of the compound into methylene chloride from plasma or urine buffered to pH 10, and the HPLC analysis of the residue dissolved in methylene chloride—methanol—heptane (85:10:5). A 10-μm silica gel column was used with methylene chloride—methanol—heptane—ammonium hydroxide (85:10:5:0.1) as the eluting solvent. The effluent was monitored at 254 nm and quantitation was based on the peak height vs. concentration technique. The assay has a recovery of 64.5 ± 4.5% (S.D.) from plasma and 96.0 ± 6.3% (S.D.) from urine in the concentration range of 0.1–2 μg per ml and 2–40 μg per 0.1 ml of plasma and urine, respectively, with a limit of detection of 0.05–0.1 μg [I] per ml of plasma using a 1-ml specimen and 0.1 μg per ml urine using a 0.1-ml specimen, respectively. The assay was applied to the determination of plasma levels and urinary excretion of the compound [I] in dog following the oral administration of 28.8 mg of [I] · maleate per kg body weight.The HPLC assay was also used to determine the stability of [I] and for the measurement of a potential degradation product, clonidine [II] [2-(2,6-dichlorophenylamino)-2-imidazoline] in pooled human plasma stored at ?17°C, and pooled human urine stored at ?17°C and ?90°C, respectively.  相似文献   

15.
Direct injection high-performance liquid chromatographic (HPLC) methods with column switching and UV detection were developed for the rapid and accurate determination of S-1090 in human plasma and urine. An internal-surface reversed-phase pre-column and a C18 analytical column were used for the plasma assay. Two pre-columns packed with cyano and phenyl materials and a C18 analytical column were used for the urine assay. The calibration curves for plasma and urine assays were linear in the ranges 0.09–9 μg/ml and 0.5–100 μg/ml of S-1090, respectively. The relative standard deviations for plasma and urine assays were less than 6% with low relative errors. The established HPLC methods were demonstrated to be useful for clinical pharmacokinetic studies after oral administration of S-1090.  相似文献   

16.
For the identification of drug abuse, a simple and rapid method which allows us to distinguish enantiomers of methamphetamine (MA) and its metabolites amphetamine (AP) and p-hydroxymethamphetamine (p-OHMA) in human urine was explored by coupling direct HPLC and HPLC-thermospray-mass spectrometry (HPLC-TSP-MS) both of which employ a β-cyclodextrin phenylcarbamate-bonded silica column. HPLC analysis was performed after the solid-phase extraction from the urine sample with Bond Elut SCX, and d- and l-enantiomers of MA, AP and p-OHMA could be separated well. The proposed conditions are as follows: eluent, acetonitrile-methanol-50 mM potassium phosphate buffer (pH 6.0) (10:30:60, v/v) flow-rate, 1.0 ml/min temperature, 25°C. The linear calibration curves were obtained for d- and l- MA and AP in the concentration range from 0.2 to 20 μg/ml; the relative standard deviation for d- and l-AP and d- and, l-MA ranged from 1.67 to 2.35% at 2 μg/ml and the detection limits were 50 ng/ml for d- and l-AP and d-MA and 100 ng/ml for l-MA. For the verification of the direct HPLC identification, HPLC-TSP-MS was also carried out under the same conditions except that acetonitrile-methanol-100 mM ammonium acetate (pH 6.0) (10:30:60, v/v) was used as an eluent. Upon applying the scan mode, 10 ng/ml for d- and l-AP and d-MA and 20 ng/ml for l-MA were the detection limits. Using the selected ion monitoring mode, 0.5 ng/ml, 0.8 ng/ml and 1 ng/ml could be detected for d- and l-AP, d-MA and l-MA, respectively.  相似文献   

17.
A high-performance liquid chromatographic (HPLC) method is described for the determination of ractopamine (LY031537) in monkey plasma and swine serum. Plasma or serum (0.5 ml) was diluted with phosphate buffer pH 7.0. Ractopamine was isolated from the plasma matrix using ion exchange on a polymeric carboxylic acid solid-phase extraction cartridge followed by partitioning with ethyl acetate. An isocratic HPLC method using electrochemical detection at +700 mV was used to separate and measure ractopamine in the purified extract in 6.5 min of run time. Standard area response was linear with respect to concentration of ractopamine over the range of 0.5 to 40 ng/ml. Validation data were collected using rhesus monkey plasma and swine serum. The method precision and accuracy were evaluated in the range 1.0 to 20 ng/ml using fortified samples of monkey plasma. The method limit of quantitation was estimated at 2 ng/ml as determined in monkey plasma.  相似文献   

18.
A micellar electrokinetic capillary chromatography (MECC) method was developed for the separation of the 3-O-glucuronides of entacapone and its (Z)-isomer, the two main urinary metabolites of entacapone in humans. Entacapone is a novel, potent inhibitor of catechol-O-methyltransferase (COMT) intended for use as an adjunct in the treatment of Parkinson’s disease. Urine samples spiked with synthetic 3-O-glucuronides were used to study the effects of running buffer pH, composition and applied voltage on separation of the closely migrating glucuronides. The 3-O-glucuronide of nitecapone, was used as internal standard. The greatest improvement in separation was achieved by increasing the running buffer ionic concentration. Changes in pH had little effect on the separation, whereas increase in sodium dodecyl sulfate (SDS) concentration slightly improved resolution. Baseline separation and good selectivity relative to urine components were achieved by using a phosphate (25 mM)–borate (50 mM)–SDS (20 mM) running buffer, pH 7.0, in a 75 μm×60/67 cm fused-silica capillary at 15 kV and a 335 nm cut-off filter in the UV detector. The limits of detection (LOD) at a signal-to-noise ratio of 3 were about 0.25 μg/ml (5.2·10 −7M) (injection 0.5 p.s.i./8 s). The linear detection range was 2–100 μg/ml (r2>0.999). Good repeatability of injection and relative migration times were obtained.  相似文献   

19.
A sensitive high-performance liquid chromatographic (HPLC) method with ultraviolet absorption detection (292 nm) was developed and validated for the determination of the new phosphodiesterase V inhibitor, DA-8159 (DA), in human plasma and urine. A single step liquid-liquid extraction procedure using ethyl ether was performed to recover DA and the internal standard (sildenafil citrate) from 1.0 ml of biological matrices combined with 200 microl of 0.1M sodium carbonate buffer. A Capcell Pak C18 UG120 column (150 mm x 4.6 mm I.D., 5 microm) was used as a stationary phase and the mobile phase consisted of 30% acetonitrile and 70% 20mM potassium phosphate buffer (pH 4.5) at a flow rate of 1.0 ml/min. The lower limit for quantification was 5 ng/ml for plasma and 10 ng/ml for urine samples. Within- and between-run accuracy and precision were < or =15 and < or =10%, respectively, in both plasma and urine samples. The recovery of DA from human plasma and urine was greater than 70%. Separate stability studies showed that DA is stable under the conditions of analysis. This validated assay was used for the pharmacokinetic analysis of DA during a phase I, rising dose study.  相似文献   

20.
A rapid and selective HPLC method has been developed for the separation and quantitation of metronidazole and its hydroxylated metabolite in human plasma, saliva and gastric juice. The assay requires a simple protein precipitation step prior to analysis and is selective, sensitive and reproducible. The limits of quantitation (0/5-ml sample) were at least 0.25 μg/ml for metronidazole and 0.20 μg/ml for its hydroxy metabolite. A Hypersil ODS 5 μm (150×4.6 mm I.D.) column was used with a mobile phase of acetonitrile-aqueous 0.05 M potassium phosphate buffer (pH 7) containing 0.1% triethylamine (10:90) delivered at a flow-rate of 1.0 ml/min.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号