首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A sensitive method has been developed for the determination of hydroxyurea in plasma and peritoneal fluid using reversed-phase high-performance liquid chromatography (HPLC) with electrochemical detection. Plasma or peritoneal fluid samples were treated with acetonitrile to precipitate proteins then injected to the HPLC. A C18 analytical column was used to separate hydroxyurea from interfering substances in the biological matrix. The mobile phase, consisting of 0.2 M sodium perchlorate–methanol (95:5, v/v) adjusted to pH 5.0, was delivered isocratically at a flow-rate of 1 ml/min and hydroxyurea was detected using a glassy-carbon electrode operating at an applied potential of +800 mV. Hydroxyurea eluted with a retention time of 3 min. The cycle time for analysis is short and the assay precision is acceptable (C.V. plasma=1.4–3.9%, C.V. peritoneal fluid=2.1–9.7%). The method has been validated and is linear from 25 to 400 ng/ml in plasma and 5 to 30 ng/ml in peritoneal fluid. The method has been shown to be applicable for pharmacokinetic studies.  相似文献   

2.
A simple and sensitive method for quantitation of HSR-609 (I) in human plasma and urine was developed using HPLC with the fluorescence labelling reagent 4-(N,N-dimethylaminosulfonyl)-7-N-piperazino-2,1,3-benzoxadiazole (DBD-PZ). Compound I was extracted from human plasma and urine, and derivatized by reaction with DBD-PZ in the presence of Mukaiyama reagent A, an equimolar solution of 2,2′-dipyridyl disulfide (DPDS) and triphenylphosphine (TPP) in acetonitrile. The reaction mixture was cleaned up by liquid-liquid extraction following the derivatization. The conjugate was analyzed by ion-pair HPLC with fluorometric detection. The quantitation limits for I were 0.5 ng/ml in plasma and 5 ng/ml in urine. Using this method, plasma concentration and urinary excretion of I were studied after oral administration of I to human volunteers.  相似文献   

3.
A sensitive and specific high-performance liquid chromatographic–tandem mass spectrometric (HPLC–MS–MS) method was developed for the determination of 3-hydroxypropylmercapturic acid (3-HPMA) in human urine. Samples were extracted using ENV+ cartridges and then injected onto a C8 Superspher Select B column with acetonitrile and formic acid as eluent (5:95, v/v). N-Acetylcysteine was used as internal standard for HPLC–MS–MS. Linearity was given in the tested range of 50–5000 ng/ml urine. The limit of quantification was 50 ng/ml. Precision, as C.V., in the tested range of 50–5000 ng/ml was 1.47–6.04%. Accuracy ranged from 87 to 114%. 3-HPMA was stable in human urine at 37°C for 24 h. The method was able to quantify 3-HPMA in urine of non-smokers and smokers.  相似文献   

4.
An HPLC method was developed for the determination of a new oxazolidinone, DA-7867 (I), in human plasma and urine and in rat tissue homogenates. To 100 microl of biological sample, 300 microl acetonitrile and 50 microl methanol containing 10 microg/ml DA-7858 (the internal standard) were added. After vortex-mixing and centrifugation, the supernatant was evaporated under a gentle stream of nitrogen. The residue was reconstituted in 100 microl of the mobile phase and a 50-microl aliquot was injected directly onto the reversed-phase (C(18)) column. The mobile phase, 20 mM KH2PO4:acetonitrile (75:25, v/v) was run at a flow rate of 1.5 ml/min and the column effluent was monitored by a UV detector set at 300 nm. The retention times of I and DA-7858 were approximately 6.5 and 8.7 min, respectively. The detection limits of I in human plasma and urine and in rat tissue homogenates were 20, 20, and 50 ng/ml, respectively.  相似文献   

5.
High-performance liquid chromatographic methods were developed for the determination of azosemide and its metabolite, M1, in human plasma and urine and rabbit blood and tissue homogenates. The methods involved deproteinization of the biological samples: 2.5 volumes of acetonitrile were used for the determination of azosemide and 1 volume of saturated Ba(OH)2 and ZnSO4 for that of M1. A 50-μl aliquot of the supernatant was injected onto a C18 reversed-phase column in each instance. The mobile phases employed were 0.03 M phosphoric acid—acetonitrile (50:40, v/v) for azosemide and 0.03 M phosphoric acid/0.2 M acetic acid—acetonitrile (83:17, v/v) for M1. The flow-rate was 1.5 ml/min in both instances. The column effluent was monitored by ultraviolet detection at 240 and 236 nm for azosemide and M1, respectively. The retention times for azosemide and M1 were 6.0 and 8.3 min, respectively. The detection limits for both azosemide and M1 in both human plasma and urine were 50 ng/ml. The coefficients of variation of the assay were generally low (below 11.0%) for plasma, urine, blood and tissue homogenates. No interferences from endogenous substances or other diuretics tested were observed.  相似文献   

6.
This paper describes two different procedures for extraction of ochratoxin A (OTA) from urine samples: one using acidic chloroform-methanol mixture, followed by solid-phase extraction (SPE) clean-up and the other using commercial Chem Elut columns and a chloroform-formic acid mixture. The recovery of OTA using the procedure with silica gel columns was 82% with a R.S.D. < 8.4% and the detection and quantitation limits were 0.5 and 1.5 ng OTA/ml, respectively. The recovery of OTA in the second procedure with urine samples purified only on commercial Chem Elut columns was 95% with R.S.D. < 4.0%, and detection and quantitation limits 0.3 and 0.9 ng/ml, respectively. Both procedures of OTA extraction effectively eliminate interfering substances and give reliable and repeatable results. However, the procedure with Chem Elut columns gave higher recovery and lower detection and quantitation limits. It was successfully applied in determining OTA in human urine samples.  相似文献   

7.
Automated procedures for the determination of CGP 33 101 in plasma and the simultaneous determination of CGP 33 101 and its carboxylic acid metabolite, CGP 47 292, in urine are described. Plasma was diluted with water and urine with a pH 2 buffer prior to extraction. The compounds were automatically extracted on reversed-phase extraction columns and injected onto an HPLC system by the automatic sample preparation with extraction columns (ASPEC) automate. A Supelcosil LC-18 (5 μm) column was used for chromatography. The mobile phase was a mixture of an aqueous solution of potassium dihydrogen phosphate, acetonitrile and methanol for the assay in plasma, and of an aqueous solution of tetrabutylammonium hydrogen sulfate, tripotassium phosphate and phosphoric acid and of acetonitrile for the assay in urine. The compounds were detected at 230 nm. The limit of quantitation was 0.11 μml/l (25 ng/mol) for the assay of CGP 33 101 in plasma, 11 μmol/l (2.5 μg/ml) for its assay in urine and 21 μmol/l (5 μg/ml) for the assay of CGP 47 292 in urine.  相似文献   

8.
The on-line combination of high-performance liquid chromatography with mass spectrometry (HPLC–MS) has become a powerful tool for trace analysis thanks to the developments in interface techniques. However, non-volatile salts such as ion-pairing reagents are considered to be incompatible with HPLC–MS systems; they cause drops in analyte signals because of contamination of mass analyzers and also because of blocking of the capillary transferring ions from atmospheric pressure to the vacuum manifold. In this work, a new type of ion-pairing reagent, di-n-butylammonium acetate (DBA), was evaluated for use in HPLC–MS. DBA did not cause these problems to HPLC–MS systems; a possible explanation might be that DBA decomposed to volatile compounds under APCI conditions. In addition, DBA was very useful for obtaining sharp peaks, which resulted in high sensitivity. With this ion-pairing reagent, we developed a procedure for the measurement of five (including internal standard) anticoagulant rodenticides in whole blood and urine samples by SIM detection of [M−H] ions. Calibration range, recoveries and precision of the method were examined; detection limits as low as 1–5 ng/ml blood sample or 0.5–2.5 ng/ml urine sample were achieved.  相似文献   

9.
A method for the simultaneous determination of de(N-methyl)-N-ethyl-8,9-anhydroerythromycin A 6,9-hemiacetal (EM523, I) and its three metabolites in human plasma and urine has been developed using high-performance liquid chromatography (HPLC) with chemiluminescence (CL) detection. Plasma and urine samples spiked with erythromycin as an internal standard were extracted with a mixture of dichloromethane and diethyl ether under alkaline conditions. The ortanic layer was evaporated under a stream of nitrogen gas. The reconstituted sample was injected into an HPLC apparatus and separated on an ODS column using a gradient elution method. The elute was reacted on-line with a mixture of tris(2,2′-bipyridine) ruthenium(II) and peroxodisulfate, and the generated CL intensity was detected. Optimization of the CL reaction conditions resulted in a sensitive and stable CL intensity for the determination of I and its metabolites. The recovery of each compound from human plasma and urine, and the sensitivity, linearity, accuracy and precision of the method were satisfactory. The lower limits of quantitation for each compound using 0.2 ml of plasma and 0.1 ml of urine were 1 and 00 ng/ml, respectively. This method has been used for the determination of I in samples from clinical trials.  相似文献   

10.
Ebrotidine is a new H2-receptor antagonist with powerful antisecretory activity, demonstrated gastroprotection and the ability to inhibit protease and lipase activities of Helicobacter pylori. As a tool in the clinical pharmacokinetic study of ebrotidine, an analytical method for the simultaneous determination of ebrotidine an its metabolites in human urine was developed. An ion-pair reversed-phase HPLC separation using 1-hexanesulfonic acid and acetonitrile as mobile phase with gradient elution was optimized. In addition, several procedures of preconcentration and clean-up were tested, including solid-phase and liquid—liquid extraction, the mixture dichloromethane—2-propanol (9:1, v/v) at pH 11 being the most efficient. The quality parameters of the whole analytical method were established, the calibration curves were linear over the range studied (1–200 μg/ml) and the reproducibility of the method was high (inter-day R.S.D. values lower than 4.4%).The limits of detection were between 26 and 110 ng/ml of urine for ebrotidine and its metabolites. The method was applied to the analysis of urine collected from two volunteers during 96 h following oral administration of ebrotidine at a dose of 400 mg.  相似文献   

11.
A high-performance liquid chromatographic method was developed for the determination of a chemoprotective agent, 2-(allylthio)pyrazine (I), in human plasma and urine, and in rat blood and tissue homogenate using diazepam as an internal standard. The sample preparation was simple; 2.5 volumes of acetonitrile were added to the biological sample to deproteinize it. A 50–100 μl aliquot of the supernatant was injected onto a C18 reversed-phase column. The mobile phase employed was acetonitrile–water (55:45, v/v), and it was run at a flow-rate of 1.5 ml/min. The column effluent was monitored using an ultraviolet detector at 330 nm. The retention times for I and the internal standard were 4.0 and 5.1 min, respectively. The detection limits of I in human plasma and urine, and in rat tissue homogenate (including blood) were 20, 20 and 50 ng/ml, respectively. The coefficients of variation of the assay (within-day and between-day) were generally low (below 6.1%) in a concentration range from 0.02 to 10 μg/ml for human plasma and urine, and for rat tissue homogenate. No interferences from endogenous substances were found.  相似文献   

12.
A high-performance liquid chromatographic method was developed for the determination of a new proton pump inhibitor, YH1885 (I), in human plasma and urine, and rat blood and tissue homogenate using fenticonazole as an internal standard. The sample preparation was simple: a 2.5 volume of acetonitrile was added to the biological sample to deproteinize it. A 50-μl aliquot of the supernatant was injected onto a C8 reversed-phase column. The mobile phase employed was methanol-0.005 M tetrabutylammonium dihydrogenphosphate (77:23, v/v), and it was run at a flow-rate of 1.0 ml/min. The column effluent was monitored using an ultraviolet detector at 270 nm. The retention times for I and the internal standard were 9.0 and 10.3 min, respectively. The detection limits for I in human plasma and urine, and in rat tissue homogenate (including blood) were 50, 100 and 100 ng/ml, respectively. The coefficients of variation of the assay (within-day and between-day) were generally low (below 8.84%) for human plasma and urine, and for rat tissue homogenate. No interferences from endogenous substances were found.  相似文献   

13.
The simultaneous isolation and determination of mitoxantrone (Novantrone ®) and its two known metabolites (the mono- and dicarboxylic metabolites) were carried out using a high-performance liquid chromatographic (HPLC) system equipped with an automatic pre-column-switching system that permits drug analysis by direct injection of biological samples. Plasma or urine samples were injected directly on to an enrichment pre-column flushed with methanol-water (5:95, v/v) as the mobile phase. The maximum amount of endogenous water-soluble components was removed from biological samples within 9 min. Drugs specifically adsorbed on the pre-column were back-flushed on to an analytical column (Nucleosil C18, 250x4.6 mm I.D.) with 1.6 M ammonium formate buffer (pH 4.0) (2.5% formic acid) containing 20% acetonitrile. Detection was effected at 655 nm. Chromatographic analysis was performed within 12 min. The detection limit of the method was about 4 ng/ml for urine and 10 ng/ml for plasma samples. The precision ranged from 3 to 11% depending on the amount of compound studied. This technique was applied to the monitoring of mitoxantrone in plasma and to the quantification of the unchanged compound and its two metabolites in urine from patients receiving 14 mg/m2 of mitoxantrone by intravenous infusion for 10 min.  相似文献   

14.
A rapid method is described for the identification and determination of amphetamine and methamphetamine in human urine samples by liquid chromatography with UV-Vis detection. The samples were transferred onto a C18 solid-phase extraction column and chromatographed on a Hypersil ODS RP C18, 5 μm (250 × 4 mm I.D.) with an acetonitrile-water elution gradient containing propylamine. Under these conditions, the amines are eluted with a short retention time. The procedure has been applied to the determination of amphetamine and methamphetamine in the range 0.3–4.0 μg/ml in spiked urine samples. The detection limits at 280 nm were 4 and 2 ng/ml for amphetamine and methamphetamine, respectively. The intra-day and inter-day precision and accuracy of the method were studied.  相似文献   

15.
A fully automated semi-microbore high performance liquid chromatographic (HPLC) method with column-switching using UV detection was developed for the determination of glimepiride from human plasma samples. Plasma sample (900 microl) was deproteinated and extracted with ethanol and acetonitrile. The extract (70 microl) was directly injected into a Capcell Pak MF Ph-1 pre-column where the primary separation occurred to remove proteins and retain drugs using a mixture of acetonitrile and 10mM phosphate buffer (pH 2.18) (20:80, v/v). The analytes were transferred from the pre-column to an intermediate column using a switching valve and then subsequently separated on an analytical column and monitored with UV detection at 228 nm. Glimepiride was eluted with retention time 34.9 min without interference of endogenous substance from plasma. The limit of quantification (LOQ) was 10 ng/ml for glimepiride. The calibration curves were linear over the concentration range of 10-400 ng/ml (r(2) = 0.9997). Moreover, inter- and intra-day precisions of the method were less than 15% and accuracies were higher than 99%. The developed method was successfully applied for the quantification of glimepiride in human plasma and was used to support a human pharmacokinetic study following a single oral administration of 2 mg glimepiride.  相似文献   

16.
Chemically modified phosphorothioate oligodeoxynucleotides (ODNs) have become critical tools for research in the fields of gene expression and experimental therapeutics. Bioanalytical assays were developed that utilized fast anion-exchange high-performance liquid chromatography (HPLC) and capillary gel electrophoresis (CGE) for the determination of 20-mer ODNs in biological fluids (plasma and urine) and tissues. A 20 mer ODN in the antisense orientation directed against DNA methyltransferase (denoted as MT-AS) was studied as the model ODN. The anion-exchange HPLC method employed a short column packed with non-porous polymer support and a ternary gradient elution with 2 M lithium bromide containing 30% formamide. Analysis of the MT-AS is accomplished within 5 min with a detection limit of approximately 3 ng on-column at 267 nm. For plasma and urine, samples were diluted with Nonidet P-40 in 0.9% NaCl and directly injected onto the column, resulting in 100% recovery. For tissue homogenates, a protein kinase K digestion and phenol–chloroform extraction were used, with an average recovery of about 50%. Since the HPLC assay cannot provide one-base separation, biological samples were also processed by an anion-exchange solid-phase extraction and a CGE method to characterize MT-AS and its catabolites of 15–20-mer, species most relevant to biological activity. One base separation, under an electric field of 400 V/cm at room temperature, was achieved for a mixture of 15–20-mer with about 50 pg injected. Assay validation studies revealed that the combined HPLC–CGE methods are accurate, reproducible and specific for the determination of MT-AS and its catabolites in biological fluids and tissue homogenates, and can be used for the pharmacokinetic characterization of MT-AS.  相似文献   

17.
A novel high-performance liquid chromatography (HPLC) assay for the estimation of formoterol in urine samples was developed and validated. A solid phase extraction (SPE) using Oasis HLB was optimised to isolate formoterol from a urine matrix followed by HPLC with UV detection. This extraction procedure concentrated the final analyte forty times so that UV detection can be used to determine even a low concentration of formoterol in urine samples. The urinary assay was performed in accordance with FDA and ICH regulations for the validation of bioanalytical samples. The samples were injected onto a C18 Spherisorb (250 mm x 4.6 mm x 5 microm) analytical column maintained at 30 degrees C. The mobile phase consisted of 5 mM of potassium dihydrogen orthophosphate buffer (adjusted to pH 3 with ortho phosphoric acid):acetonitrile (ACN) (70:30, v/v), and the formoterol peak was detected at wavelength 214 nm. The extraction recovery of formoterol from the urine sample was >95%. The calibration curve was linear (r2=0.99) over formoterol concentrations ranging from 1.5 to 25 ng/mL (n=6). The method had an accuracy of >92% and intra and inter-day precision CV% of <3.9% and <2.2%, respectively, at three different concentrations low, medium and high (10, 15, 20 ng/mL). The limit of quantification (LOQ) for formoterol was found to be 1.50 ng/mL. The accuracy and precision at the LOQ level were 95% and %CV <3.7% (n=10), respectively. The method reported is simple, reliable, precise, and accurate and has the capacity to be used for determination of formoterol in urine samples.  相似文献   

18.
Introduction – Biflavones of Hypericum perforatum L. are bioactive compounds used in the treatment of inflammation and depression. Determination of amentoflavone and biapigenin from blood is challenging owing to their similar structures and low concentrations. Objective – To develop a rapid, sensitive and accurate method based on liquid‐phase extraction followed by high‐performance liquid chromatography and electrospray ionisation mass spectrometry (HPLC‐ESI‐MS) for quantification of biflavones in human plasma. Methodology – After extraction from blood, the analytes were subjected to HPLC with an XTerra® MS C18 column and a binary mobile phase consisting of 2% formic acid in water and acetonitrile under isocratic elution conditions, with ESI‐MS detection in the negative ion mode and multiple reaction monitoring (MRM). Results – Both calibration curves showed good linearity within the concentration range 1–500 ng/mL. Limits of detection (S/N = 3) were 0.1 ng for pure substances and the limits of quantitation (S/N = 5) were 1.0 ng/mL from analyte‐spiked serum. The grand mean recovery was 90% from several subsamples of each biflavone. The imprecision (RSD) of peak areas was between 5% (intraday) and 10% (interday) for high concentrations (250 ng/mL) and between 10% (intraday) and 15% (interday) for low concentrations (1 ng/mL). Inaccuracy of the mean was less than 20% at the lower limit of quantitation. Conclusion – The developed and validated method for determination of biflavones from human plasma was effectively applied to pharmacokinetic studies of 13 probands and preliminary results indicate biphasic concentration–time curves. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

19.
Tea polyphenols are strong antioxidants and are believed to have beneficial health effects. However, the blood and tissue levels of these compounds are not well characterized because of a lack of suitable analytical methods for the biological resolution of these compounds. Previously, we developed methods for the analysis of three green tea catechins. Now we report an improved method for the measurement of the levels of the different catechins and theaflavins in biological fluids and tissues. The method includes digestion of the plasma, urine, or tissue samples with beta-d-glucuronidase and sulfatase, followed by extraction with ethyl acetate and subsequent separation by reversed-phase high-performance liquid chromatography (HPLC). The polyphenols are identified on the basis of their retention times, spectral analysis, and electrochemical behavior across an array of electrodes. In a single HPLC run, it is possible to determine the major catechins and theaflavins as well as some of the catechin metabolites. The detection limits for catechins and theaflavins are from 5 to 10 ng/ml of saliva, plasma, or urine.  相似文献   

20.
We present a method for determining two cephalosporins (cefoperazone and ceftiofur) in plasma by on-line solid-phase extraction (SPE)-capillary zone electrophoresis (CZE) with a T-split interface. Using this interface, a part of the SPE elution plug containing the cephalosporins is injected while the rest of the sample is flushed to waste. SPE was carried out using a C(18) micro-precolumn and the cephalosporins presented good retention properties with breakthrough volumes above 1 ml. Using a desorption volume of 426 nl of acetonitrile, recoveries were 75 and 90%, for cefoperazone and ceftiofur, respectively. The resulting elution volume was about 1.8 microl. A deproteinization step was included prior to SPE for the analysis of plasma samples with recoveries of 90 and 57% for cefoperazone and ceftiofur, respectively. With UV detection at 254 nm, linear relationships between the injected concentration and peak area was measured between 10 and 500 ng ml(-1) for standards, and 200 and 1500 ng ml(-1) for plasma samples. Intra-day (n=5) and inter-day (n=5) peak area repeatability were lower than 12% RSD. The detection limits obtained for spiked plasma (100 ng ml(-1) cefoperazone and ceftiofur) are sufficient for applying the method to pharmacokinetic studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号