1.
A system for an automatic sample preparation procedure followed by on-line injection of the sample extract into a gas chromatography–mass spectrometry (GC–MS) system was developed for the simultaneous analysis of seven barbiturates in human urine. Sample clean-up was performed by a solid-phase extraction (SPE) on a C18 disposable cartridge. A SPE cartridge was preconditioned with methanol and 0.1 M phosphate buffer. After loading a 1.5 ml volume of a urine sample into the SPE cartridge, the cartridge was washed with 2.5 ml of methanol–water (1:9, v/v). Barbiturates were eluted with 1.0 ml of chloroform–isopropanol (3:1, v/v) from the cartridge. The eluate (1 μl) was injected into a GC–MS system. The calibration curves, using an internal standard method, demonstrated a good linearity throughout the concentration range from 0.02 to 10 μg/ml for all barbiturates extracted. The proposed method was applied to several clinical cases. The total analysis time for 20 samples was approximately 14 h.  相似文献   

2.
A system of an automatic sample preparation procedure followed by on-line injection of the sample extract into a gas chromatograph-mass spectrometer (GC–MS) was developed for the simultaneous analysis of seven barbiturates in human serum. A sample clean-up was performed by a solid-phase extraction (SPE) on a C18 disposable cartridge. A SPE cartridge was preconditioned with methanol and 0.1 M phosphate buffer. After loading 1.5 ml of a diluted serum sample into the SPE cartridge, the cartridge was washed with 2.5 ml of methanol–water (1:9, v/v). Barbiturates were eluted with 1.0 ml of chloroform–isopropanol (3:1, v/v) from the cartridge. The eluate (1 μl) was injected into the GC–MS. The calibration curves, using an internal standard method, demonstrated a good linearity throughout the concentration range from 0.1 to 10 μg ml−1 for all barbiturates extracted. The proposed method was applied to 27 clinical serum samples from three patients who were administrated secobarbital.  相似文献   

3.
The semi-automatic bioanalytical assays for olpadronate [(3-dimethylamino-1-hydroxypropylidene)bisphosphonate] involves a protein precipitation with trichloroacetic acid and a double co-precipitation with calcium phosphate for serum samples and a triple calcium co-precipitation for urine samples. These manual procedures are followed by an automated solid-phase extraction on a cation-exchange phase. The procedure is continued either directly, at high olpadronate levels in urine, or after off-line evaporation under nitrogen and reconstitution in water on the same robotic workstation. The continued automatic procedure comprehends derivatization with (9-fluorenylmethyl)chloroformate, ion-pair liquid–liquid extraction and ion-pair HPLC with fluorescence detection at 274/307 nm. The intra- and inter-day precisions for urine and serum samples are typically in the 5–8% range for different olpadronate concentrations [levels near the lower limit of quantification (LLQ) excluded]. The LLQ is 5 ng/ml olpadronate for a 2.5-ml urine sample and 10 ng/ml for a 1-ml serum sample, respectively.  相似文献   

4.
An effective method based on solid-phase extraction (SPE) and capillary electrophoresis (CE) for the determination of kanamycin in human serum was developed and validated. Off-line SPE was employed for the isolation of kanamycin from serum on a carboxypropyl-bonded phase (CBA) weak cation-exchange cartridge. A mixture of 0.2 M borate (pH 10.5)-methanol (50:50, v/v) was used as analyte eluting solvent. After pre-capillary derivatization with o-phthalaldehyde/mercaptoacetic acid reagent, the sample was analyzed by CE with a separation buffer of 30 mM borax, pH 10.0, containing 16% (v/v) methanol. A linear response over the concentration range 5-40 microgram/ml was obtained with a detection limit of 2 microgram/ml. Intra-day and inter-day precision were 6.2 and 10.3% RSD, respectively. Recoveries of approximately 90% were found. For the determination of lower levels of kanamycin (<5 microgram/ml), NH(4)OH (25%, w/v)-methanol (30:70, v/v) was used for analyte elution. After evaporation, reconstitution and derivatization, the sample was analyzed by on-line field-amplified sample stacking (FASS) CE. Good linearity in the concentration range 0.4-5 microgram/ml was obtained with a detection limit of 0.1 microgram/ml. Intra-day and inter-day RSD were 3.4 and 11.2%, respectively. Recoveries of approximately 60% were found. The method was successfully applied to the analysis of kanamycin in sera of tuberculosis patients at peak level and trough level concentrations.  相似文献   

5.
Human serum 8-hydroxy-2′-deoxyguanosine (8-OHdG) was measured by HPLC-ECD method combined with solid phase extraction (SPE) developed by our group: (our proprietary kit, named 8-OHdG Pre-treatment Kit (TANITA Corporation)). The major interfering substances and proteins in serum were removed by 8-OHdG Pre-treatment Kit. This measurement method was highly reproducible (CV = 2.2–7.1%) and demonstrated the lower detection limit for control serum sample of less than 10 pg/ml without the sample evaporation. The other hand 8-OHdG concentration in serum for healthy people was in the range of 0–70 pg/ml (25.5 ± 13.8 pg/ml, n = 37). Secondary a relationship between the HPLC-ECD and ELISA methods was investigated. ELISA method could not detect 8-OHdG concentration in serum for healthy people, because the detection limit of 130 pg/ml was higher than the normal range for healthy people. These results show our SPE method has high sensitivity and quantitative accuracy for 8-OHdG analysis.  相似文献   

6.
Two modifications of the HPLC–ED method with respect to extraction procedure used have been developed for psilocin, the active metabolite of psilocybin, in human plasma using either liquid–liquid extraction (LLE) or automated on-line solid-phase extraction (on-line SPE). Each type of the sample preparation required a different HPLC system followed by electrochemical detection at 650 to 675 mV. The limit of quantitation of both modifications was 10 ng/ml psilocin. There was no significant difference observable between the LLE and the on-line SPE in terms of method standard deviation (LLE 1.82%, on-line SPE 1.13%) and the analytical results. However, the advantages of on-line SPE in addition to different selectivity were less manual effort, smaller plasma volumes of 400 μl (LLE 2 ml) and a recovery of psilocin in human plasma of nearly 100% (LLE 88%). In contrast to a previous procedure both methods were rapid, simple and reliable and yielded high plasma recoveries. They were used successfully in the quantitation of psilocin in plasma samples obtained from healthy volunteers after p.o. administration of 0.2 mg psilocybin per kg body mass. Plasma concentration curves and pharmacokinetic parameters were calculated.  相似文献   

7.
1. Monosaccharides, amino sugars and N-acetylneuraminic acid were determined by using an original colorimetric assay procedure, based on the detection of formaldehyde released after periodate oxidation. A range of these compounds was investigated by this method and they were all found to obey Beer's law within the concentration range 0-0.6mumole/ml. 2. A simple method for the determination of 6-deoxyhexose concentration in the presence of other monosaccharides is also described. 3. The optimum pH for the release of formaldehyde from sugars by periodate oxidation was 7.0-7.5. 4. The methods described have considerable advantages over existing assay systems and their particlar value in automatic colorimetry, where the use of concentrated acids is undesirable, is discussed.  相似文献   

8.
We improved our previous analytical method to measure phthalate metabolites in urine as biomarkers for phthalate exposure by automating the solid-phase extraction (SPE) procedure and expanding the analytical capability to quantify four additional metabolites: phthalic acid, mono-3-carboxypropyl phthalate, mono-isobutyl phthalate (miBP), and monomethyl isophthalate. The method, which involves automated SPE followed by isotope dilution-high performance liquid chromatography (HPLC)-electrospray ionization (ESI)-tandem mass spectrometry (MS), allows for the quantitative measurement of 15 phthalate metabolites in urine with detection limits in the low ng/ml range. SPE automation allowed for the unattended sequential extraction of up to 100 samples at a time, and resulted in an increased sample throughput, lower solvent use, and better reproducibility than the manual SPE. Furthermore, the modified method permitted for the first time, the separation and quantification of mono-n-butyl phthalate (mBP) and its structural isomer miBP. The method was validated on spiked pooled urine samples and on pooled urine samples from persons with no known exposure to phthalates.  相似文献   

9.
A selective, accurate, and reproducible LC/MS/MS assay was developed and validated for the determination of the HIV protease inhibitor atazanavir (BMS-232632) in human peripheral blood mononuclear cells (PBMC) samples. In addition to the details of the validated LC/MS/MS method, a practical procedure is described in great detail for the preparation of large supplies of control (blank) PBMC from units of blood (each unit of blood is about 500 ml) for making the calibration standards and quality control (QC) samples. The PBMC assay design, intended for high-throughput sample analysis, is also described in some detail in regards to the composition and concentration expressions of the calibration standards and QC samples, the lysing procedure of the PBMC samples, and the final analysis/quantitation procedure. The method involved automated solid-phase extraction (SPE) of atazanavir and a stable isotope analog internal standard (I.S.) using 3M Empore C2-SD 96-well plates. A portion of the reconstituted sample residue was injected onto a YMC Basic analytical column which was connected to a triple quad mass spectrometer for analyte determination by positive-ion electrospray in the selected reaction monitoring (SRM) mode. The standard curve, which ranged from 5 to 2500 fmol per one million cells (fmol/10(6) cells), was fitted to a quadratic regression model weighted by 1/concentration. The lower limit of quantitation (LLOQ) was 5 fmol/10(6) cells. The inter- and intra-run coefficients of variation (CV) for the assay were <9% and the accuracy was 94-104%. Atazanavir was stable in PBMC for at least 24h at room temperature and for at least 129 days at -15 degrees C.  相似文献   

10.
An assay employing automated solid-phase extraction (SPE) followed by high-performance liquid chromatography with positive ion TurboIonspray tandem mass spectrometry (LC-MS-MS) was developed and validated for the quantification of rosuvastatin (Crestor) in human plasma. Rosuvastatin is a hydroxy-methyl glutaryl coenzyme A reductase inhibitor currently under development by AstraZeneca. The standard curve range in human plasma was 0.1-30 ng/ml with a lower limit of quantification (LLOQ) verified at 0.1 ng/ml. Inaccuracy was less than 8% and imprecision less than +/-15% at all concentration levels. There was no interference from endogenous substances. The analyte was stable in human plasma following three freeze/thaw cycles and for up to 6 months following storage at both -20 and -70 degrees C. The assay was successfully applied to the analysis of rosuvastatin in human plasma samples derived from clinical trials, allowing the pharmacokinetics of the compound to be determined.  相似文献   

11.
12.
An new method for the determination of polychlorinated biphenyls (PCBs) in serum samples of up to 1 ml has been developed. The procedure consisted in the solid-phase extraction (SPE) of the analytes on an Oasis cartridge and the subsequent on-line elimination of the fat by directly dropping of the eluate from the SPE cartridge on a multilayer column placed below the cartridge. This configuration allowed minimising of the sample manipulation as well as the time, solvent and sorbent consumption (i.e. complete sample preparation can be accomplished in about 1 h with only 3 ml of toluene and 300 mg of silica). The SPE plus clean-up method developed showed a satisfactory performance for the analysis of PCBs in rat serum samples providing similar recoveries (i.e. range 73-128% for most of the congeners selected) at the different spiking levels investigated (1.25, 0.50 and 0.25 ng/ml). Detection limits using a microelectron capture detector were in the range 0.01-0.30 ng/ml of serum and the relative standard deviations of the complete method better than 18% irrespective of the PCB concentration. The validated method has been applied to the evaluation for the first time of the PCB levels in serum samples of up to 1 ml from individuals of an Egyptian Vulture colony in Spain.  相似文献   

13.
A specific LC-MS/MS assay was developed for the automated determination of talinolol in human plasma, using on-line solid phase extraction system (prospekt 2) combined with atmospheric pressure chemical ionization (APCI) tandem mass spectrometry. The method involved simple precipitation of plasma proteins with perchloric acid (contained propranolol) as the internal standard (IS) and injection of the supernatant onto a C8 End Capped (10 mmx2 mm) cartridge without any evaporation step. Using the back-flush mode, the analytes were transferred onto an analytical column (XTerra C18, 50 mmx4.6 mm) for chromatographic separation and mass spectrometry detection. One of the particularities of the assay is that the SPE cartridge is used as a column switching device and not as an SPE cartridge. Therefore, the same SPE cartridge could be used more than 28 times, significantly reducing the analysis cost. APCI ionization was selected to overcome any potential matrix suppression effects because the analyte and IS co-eluted. The mean precision and accuracy in the concentration range 2.5-200 ng/mL was found to be 103% and 7.4%, respectively. The data was assessed from QC samples during the validation phase of the assay. The lower limit of quantification was 2.5 ng/mL, using a 250 microL plasma aliquot. The LC-MS/MS method provided the requisite selectivity, sensitivity, robustness accuracy and precision to assess pharmacokinetics of the compound in several hundred human plasma samples.  相似文献   

14.
We have developed and validated a sensitive and selective assay for the quantification of paclitaxel and its metabolites 6α,3′-p-dihydroxypaclitaxel, 3′-p-hydroxypaclitaxel and 6α-hydroxypaclitaxel in plasma, tissue, urine and faeces specimens of mice. Tissue and faeces were homogenized (approximately 0.1–0.2 g/ml) in bovine serum albumin (40 g/I) in water, and urine was diluted (1:5, v/v) in blank human plasma. Sample pretreatment involved liquid-liquid extraction of 200–1000 μl of sample with diethyl ether followed by automated solid-phase extraction using cyano Bond Elut column. 2′-Methylpaclitaxel was used as internal standard. The overall recovery of the sample pretreatment procedure ranged from 76 ot 85%. In plasma, the lower limit of detection (LOD) and the lower limit of quantitation (LLQ) are 15 and 25 ng/ml, respectively, using 200 μl of sample. In tissues, faeces and urine the LLQs are 25–100 ng/g, 125 ng/g and 25 ng/ml, respectively, using 1000 μl (faeces: 200 μl) of homogenized or diluted sample. The concentrations in the various biological matrices, for validation procedures spiked with known amounts of the test compounds, are read from calibration curves constructed in blank human plasma in the range 25–100 000 ng/ml for paclitaxel and 25–500 ng/ml for the metabolites. The accuracy and precision of the assay fall within the generally accepted criteria for bio-analytical assays.  相似文献   

15.
Three extraction procedures were developed for the quantitative determination of a carboxylic acid containing analyte (I) in human plasma by high-performance liquid chromatography (HPLC) with negative ion electrospray tandem mass spectrometry (MS–MS). The first procedure was based on the manual liquid–liquid extraction (LLE) of the acidified plasma samples with methyl tert.-butyl ether. The second procedure was based on the automation of the manual LLE procedure using 96-well collection plates and a robotic liquid handling system. The third approach was based on automated solid-phase extraction (SPE) using 96-well SPE plates and a robotic liquid handling system. A lower limit of quantitation of 50 pg/ml was achieved using all three extraction procedures. The total time required to prepare calibration curve standards, aliquot the standards and plasma samples, and process a total of 96 standards and samples by manual LLE was three-times longer than the time required for 96-well SPE or 96-well LLE (4 h, 50 min vs. 1 h, 43 min). Even more importantly, the time the bioanalyst physically spent on the 96-well LLE or 96-well SPE procedure was only a small fraction of the time spent on the manual LLE procedure (<10 min vs. 4 h, 10 min). It should be noted that the 96-well SPE procedure incorporated the two steps of evaporation of the eluates to dryness and subsequent reconstitution of the dried extract. The total time required for the 96-well SPE could be reduced by 50% if the eluates were injected directly, eliminating the drying and reconstitution steps, which is achievable when sensitivity is less of an issue.  相似文献   

16.
A reversed-phase high-performance liquid chromatographic assay for the simultaneous determination of phenytoin and fosphenytoin, a prodrug for phenytoin, in human plasma and plasma ultrafiltrate is described. For plasma, the method involves simple extraction of drugs with diethyl ether and evaporation of solvent, followed by injection of the reconstituted sample onto a reversed-phase C18 column. Plasma ultrafiltrate is injected directly into the HPLC column. Compounds are eluted using an ion-pair mobile phase containing 20% acetonitrile. The eluent is monitored by UV absorbance at 210 nm. The fosphenytoin standard curves are linear in the concentration range 0.4 to 400 μg/ml for plasma and 0.03 to 80 μg/ml for ultrafiltrate. Phenytoin standard curves are linear from 0.08 to 40 μg/ml for plasma and from 0.02 to 5.0 μg/ml for ultrafiltrate. No interferences with the assay procedure were found in drug-free blank plasma or plasma ultrafiltrate. Relative standard deviation for replicate plasma or ultrafiltrate samples was less than 5% at concentrations above the limit of quantitation for both within- and between-run calculations.  相似文献   

17.
The characteristics of automated on-line solid phase extraction with liquid chromatography-mass spectrometry (SPE-LC-MS) are very amenable for flexibility and throughput in therapeutic drug monitoring (TDM). We demonstrate this concept of automated, on-line SPE-LC-MS for the analysis of clozapine and metabolites (desmethylclozapine and clozapine-N-oxide) in serum. Method development, optimisation and validation are described and a comparison with previously published methods for the determination of clozapine and metabolites in serum and plasma is made. Optimisation of chromatographic and SPE conditions for increased throughput resulted in SPE-LC-MS cycle times of only about 2.2 min, demonstrating the great potential of automated on-line SPE-LC-MS for TDM. The new method is shown to be clearly favourable, in particular in terms of ease of sample handling, throughput and detection limits. Recovery is essentially quantitative. Detection limits are at about 0.15-0.3 ng ml(-1), depending on the ionisation source used. Calibration follows a quadratic model for clozapine and its N-oxide and a linear model for the desmethyl metabolite (all cases: R > 0.99). Accuracy, evaluated at three concentration levels spanning the whole therapeutic range, shows that bias is less than 10%. Precision (intra - and inter assay) ranges from about 5% R.S.D. at the high end of the therapeutic range (700-1,000 ng ml(-1)) to about 20% R.S.D. (OECD defined limit) at the lower limit of quantitation ( approximately 50 ng ml(-1)). The lower limit of quantitation is well below the low end of the therapeutic range at 350 ng ml(-1).  相似文献   

18.
A selective, accurate, and reproducible LC-MS-MS assay was developed for the determination of the HIV protease inhibitor atazanavir (BMS-232632) in human plasma samples. The method involved automated solid-phase extraction of atazanavir and a stable isotope analog internal standard (I.S.) using Oasis HLB 10 mg 96-well SPE plates. A portion of the reconstituted sample residue was injected onto a C(18) HDO analytical column which was configured with a triple quad mass spectrometer for analyte determination by positive ion electrospray. The assay was linear from 1.00 to 1,000 ng/ml with a lower limit of quantitation of 1.00 ng/ml. The inter- and intra-day coefficients of variation (C.V.) for the assay were <4%, and the accuracy was 99-102%. Atazanavir was stable in human plasma for at least 109 h at room temperature and for at least 1 year at -20 degrees C.  相似文献   

19.
A solid-phase extraction (SPE) procedure was developed for the quantification of nalbuphine in a small volume (500 μl) of human plasma with subsequent assay by high-performance liquid chromatography (HPLC) and electrochemical detection using 6-monoacetylmorphine as internal standard. Plasma was extracted using Bond Elute certified extraction columns (LCR: 10 ml, 130 mg) after conditioning with methanol and 0.2 M Tris buffer (pH 8). Elution was performed with a CH2Cl2-isopropanol-NH4OH (79:20:, v/v). The organic phase was evaporated to dryness and resuspended in HPLC mobile phase containing 2% isopropanol. Linearity was assessed over the 5–100 ng/ml concentration range and a straight line passing through the origin was obtained. Experiments with spiked plasma samples resulted in recoveries of 95±5.4% and 98±6.2% for nalbuphine and 6-monoacetylmorphine, respectively. The optimal pH conditions for the SPE were found at pH 8. The intra-day coefficients of variation (C.V.) for 5, 40, and 100 ng/ml were 5.3, 3.0 and 2.3% (n=8) and the inter-day C.V.s were 7.7, 3.2 and 3.5% (n=10), respectively. The detection limit for 500 μl plasma sample was 0.02 ng/ml and the limit of quantification 0.1 ng/ml (C.V.=12.4%). The ease of the proposed method of analysis, as well as its high accuracy and sensitivity allow its application to pharmacokinetic studies. A preliminary kinetic profile of nalbuphine after rectal administration in a pediatric patient is presented.  相似文献   

20.
The aim of this study was to develop a specific and sensitive high-performance liquid chromatographic assay for the determination of linezolid in human plasma, and bronchoalveolar lavage. The sample extraction was based on a fully automated solid-phase extraction with an OASIS HLB cartridge. The method used ultraviolet detection set at a wavelength of 254 nm and a separation with a Zorbax Eclipse XDB C8 column. The assay has been found linear over the concentration range 0.02-30 microg/ml and 0.04-30 microg/ml for linezolid, respectively, in plasma and bronchoalveolar lavage. It provided good validation data for accuracy and precision (CV <4.64% and 5.08%, accuracy in the range 96.93-102.67% and 97.33-105.67%, respectively, for intra- and inter-day). The assay will be applied to determine the penetration of linezolid in human bronchoalveolar lavage during pharmacokinetic steady-state.  相似文献   