首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple and sensitive high-performance liquid chromatographic (HPLC) method was developed for the determination of SCH 27899, an everninomycin antibiotic, in rat plasma. The method involved plasma protein precipation with acetonitrile, followed by reversed-phase HPLC analysis using a polymeric column and a mobile phase containing acetonitrile and ammonium phosphate, pH 7.8. The linear relationship between detector response and concentration was demonstrated with a correlation coefficient of larger than 0.996 at concentrations ranging from 0.2 to 100 μg/ml. The results showed that the HPLC method was accurate (bias ≤6%) and precise (coefficient of variation, C.V.≤6%). The limit of quantitation was 0.2 μg/ml with a C.V. of 2.6% and bias of 5%. SCH 27899 was stable in rat plasma at −20°C for at least 40 days. The HPLC method has been utilized for the determination of SCH 27899 in plasma samples from rats following single intravenous administration (3 mg/kg).  相似文献   

2.
An HPLC system using a simple liquid-liquid extraction and HPLC with UV detection has been validated to determine tramadol concentration in human plasma. The method developed was selective and linear for concentrations ranging from 10 to 2000 ng/ml with average recovery of 98.63%. The limit of quantitation (LOQ) was 10 ng/ml and the percentage recovery of the internal standard phenacetin was 76.51%. The intra-day accuracy ranged from 87.55 to 105.99% and the inter-day accuracy, 93.44 to 98.43% for tramadol. Good precision (5.32 and 6.67% for intra- and inter-day, respectively) was obtained at LOQ. The method has been applied to determine tramadol concentrations in human plasma samples for a pharmacokinetic study.  相似文献   

3.
A simple and sensitive column-switching HPLC method has been developed for the simultaneous determination of NK-104 (HMG–CoA reductase inhibitor) and its lactone in human and dog plasma. Plasma sample was extracted with methyl tert-butyl ether and then the extract was subjected to methylation with diazomethane to prevent the mutual conversion between NK-104 and its lactone. The extract was injected into the column-switching HPLC system. The calibration curves of NK-104 and NK-104 lactone were linear over the ranges 0.5 to 100 ng/ml for human plasma samples and 0.5 to 500 ng/ml for dog plasma, respectively. The intra-day and inter-day C.V. values of these analytes were less than 13.3%. The intra-day and inter-day accuracies of these analytes were between −14.0 and 6.5%. The proposed method has been applied to plasma samples obtained after oral administration of a single 2 mg dose of NK-104 to volunteers.  相似文献   

4.
An HPLC system using solid-phase extraction and HPLC with UV detection has been validated in order to determine tramadol and o-desmethyltramadol (M1) concentrations in human plasma. The method developed was selective and linear for concentrations ranging from 50 to 3500 ng/ml (tramadol) and 50 to 500 ng/ml (M1) with mean recoveries of 94.36±12.53% and 93.52±7.88%, respectively. Limit of quantitation (LOQ) was 50 ng/ml. For tramadol, the intra-day accuracy ranged from 95.48 to 114.64% and the inter-day accuracy, 97.21 to 103.24%. Good precision (0.51 and 18.32% for intra- and inter-day, respectively) was obtained at LOQ. The system has been applied to determine tramadol concentrations in human plasma samples for a pharmacokinetic study.  相似文献   

5.
An improved HPLC method using a silica gel column with fluorescence detection (excitation at 300 nm and emission at 365 nm) was developed for the determination of sulpiride concentrations in plasma. Analysis of sulpiride in plasma samples was simplified by a one-step liquid–liquid extraction after alkaline treatment of only 1 ml of plasma. The low limit of quantitation was 20 ng/ml with a coefficient of variation of less than 20%. A linear range was found from 20 to 1500 ng/ml. This HPLC method was validated with the precision for inter-day and intra-day runs being 0.36–8.01% and 0.29–5.25%, respectively, and the accuracy (standard deviation of mean, SD) for inter-day and intra-day runs being −1.58 to 5.02% and −2.14 to 5.21%, respectively. Bioequivalence of the two products was evaluated in 12 normal healthy male volunteers in a single-dose, two-period, two-sequence, two-treatment cross-over study. Sulpiride plasma concentrations were analyzed with this validated HPLC method. Results demonstrated that the two tablet formulations of sulpiride appear to be bioequivalent.  相似文献   

6.
BAY 43-9006 is a selective Raf-1 kinase inhibitor with antitumor activity against a variety of human cancers. A highly sensitive HPLC method for determination of BAY 43-9006 in small volumes of serum (30 microl) was developed. Sample preparation involved a liquid-liquid extraction procedure with tolnaftate as internal standard followed by linear gradient elution at a reversed phase C18 column and UV detection. The method was selective and the calibration curves were linear over the concentration range of 80-2000 ng/ml. The intra-day accuracy ranged from 99.9 to 107.6% and the inter-day accuracy from 94.6 to 115%. The lower limit of quantitation (LOQ) was 80 ng/ml with an accuracy of 105.8%. Thus, this method has been validated and can be applied for the drug monitoring or pharmacokinetic studies of BAY 43-9006 in small volumes of serum samples.  相似文献   

7.
An improved HPLC method was developed for the determination of sildenafil concentrations in plasma. Analysis of sildenafil in plasma samples was simplified by utilizing a one-step liquid-liquid extraction after alkaline treatment of only 1 ml of plasma. The lower limit of quantitation was 10 ng/ml with a coefficient of variation of less than 20%. A linear range was found to exist from 10 to 1000 ng/ml. This HPLC method was validated with precisions (coefficient of variation, C.V.) for inter- and intra-day runs of 0.41-11.15% and 0.36-8.05%, respectively, and accuracies (the relative error of the mean, REM) for inter- and intra-day runs of -8.72-6.81% and 0.41-11.15%, respectively. A bioavailability study of sildenafil was performed on one normal healthy male volunteer by analyzing sildenafil plasma concentrations with this validated HPLC method. Results demonstrated that this HPLC method is appropriate for applications to bioavailability studies of sildenafil. In addition, an example of the influence of the co-administration of grapefruit juice on sildenafil pharmacokinetics in a healthy volunteer is presented.  相似文献   

8.
A method based on LC-MS-MS is described for the determination of methyldopa in human plasma using dopa-phenyl-D3 as the internal standard. The method has a chromatographic run time of 5.5 min and was linear in the range of 20-5000 ng/ml. The limit of quantitation was 20 ng/ml, the intra-day precisions were 7.3, 5.4 and 4.3% and the intra-day accuracies were -8.0, -1.3 and -2.0% for 30, 600 and 3000 ng/ml, respectively. The inter-day precisions were 7.7, 0.5 and 0.7% and the inter-day accuracies were 0.2, -1.1 and -2.3%, respectively, for the above concentrations. This method was employed in a bioequivalence study of two tablet formulations of methyldopa.  相似文献   

9.
A rapid and sensitive high performance liquid chromatography (HPLC) method with fluorescence detection has been developed for the determination of sumatriptan in human plasma. The procedure involved a liquid-liquid extraction of sumatriptan and terazosin (internal standard) from human plasma with ethyl acetate. Chromatography was performed by isocratic reverse phase separation on a C18 column. Fluorescence detection was achieved with an excitation wavelength of 225 nm and an emission wavelength of 350 nm. The standard curve was linear over a working range of 1-100 ng/ml and gave an average correlation coefficient of 0.9997 during validation. The limit of quantitation (LOQ) of this method was 1 ng/ml. The absolute recovery was 92.6% for sumatriptan and 95.6% for the internal standard. The inter-day and intra-day precision and accuracy were between 0.8-3.3 and 1.1-6.3%, respectively. This method is simple, sensitive and suitable for pharmacokinetics or bioequivalence studies.  相似文献   

10.
SCH 56592 is a novel triazole antifungal agent that is active both orally and intravenously in animal models of infection. This compound is in Phase II-III clinical trials for the treatment of systemic fungal infections. SCH 56592 is a single enantiomer with four stereogenic centers; therefore, it was necessary to evaluate the possible chiral inversion of this drug candidate in animals and humans. Thus, chiral high-performance liquid chromatographic (HPLC) methods have been developed to separate SCH 56592 from its diastereomers and to evaluate its chiral inversion in rats, dogs, cynomolgus monkeys, and humans. Chiral HPLC analysis involved the use of a Chiralcel OD column set at 39 degrees C with a mobile phase of hexane-ethanol-diethylamine and a fluorescence detector set at an excitation wavelength of 270 nm and an emission wavelength of 390 nm. Plasma or serum samples were subjected to solid phase extraction on a C(2) cartridge followed by HPLC analysis. The method was sensitive with a limit of quantitation of 0.1 microg/ml in dog serum. The linearity was satisfactory, as shown by correlations of >0.997 and by visual examination of the calibration curves. The precision and accuracy were satisfactory, as indicated by coefficients of variation (CV) ranging from 1.1 to 12.1% and bias values ranging from -11.0 to 9.0%. Chiral HPLC analysis indicated that SCH 56592 was not subjected to chiral inversion in rats, dogs, cynomolgus monkeys, and humans.  相似文献   

11.
A simple, specific and sensitive high-performance liquid chromatographic (HPLC) method was developed for the determination of rifabutin in human plasma. Rifabutin and sulindac (internal standard) are extracted from human plasma using a C8 Bond Elut extraction column. Methanol (1 ml) is used to elute the compounds. The methanol is dried down under nitrogen and reconstituted in 250 μl of mobile phase. Separation is achieved by HPLC on a Zorbax Rx C8 column with a mobile phase composed of 0.05 M potassium dihydrogen phosphate and 0.05 M sodium acetate at pH 4.0-acetonitrile (53:47, v/v). Detection is by ultraviolet absorbance at 275 nm. The retention times of rifabutin and internal standard were approximately 10.8 and 6.9 min, respectively. The assay is linear over the concentration range of 5–600 ng/ml. The quantitation limit was 5 ng/ml. Both intra-day and inter-day accuracy and precision data showed good reproducibility.  相似文献   

12.
A sensitive and specific high performance liquid chromatographic method for quantitation of topiramate in human serum was developed using HPLC with fluorescence labeling reagent. Topiramate was extracted from human serum by dichloromethane and derivatized by reaction with 9-fluorenylmethyl chloroformate (FMOC-Cl) in the presence of borate buffer. Analysis was performed on a CN column with sodium phosphate buffer (pH 2.2) containing 1 ml/l triethylamine and methanol (52:48 (v/v)) as mobile phase. Amantadine was used as internal standard. The standard curve was linear over the range 20-5000 ng/ml of topiramate in human serum. The mean intra-day precision was from 10.5% (low concentration) to 1.2% (high concentration) and the within-day precision from 1.5 to 12.5% determined on spiked samples. The accuracy of the method was 96.5-107.5% (intra-day) and 98.4-105% (inter-day). The limit of quantification was 20 ng/ml of serum. This method was used in a bioequivalence study after administration of 2 x 25 mg topiramate in 24 healthy volunteers.  相似文献   

13.
A rapid, sensitive and robust sample preparation procedure for the quantitative determination of indinavir in human cerebrospinal fluid (CSF) and plasma is described. Indinavir and the internal standard were isolated from CSF or plasma samples by cation-exchange solid-phase extraction with SCX cartridges, while the chromatographic separation was adopted from a previous method, using a cyano column connected by a switching valve to a C18 column. UV detection was set at 210 nm. The standard curve was linear over the concentration range of 2 to 2000 ng/ml in CSF and 5 to 2000 ng/ml in plasma. The intra-day coefficients of variation at all concentration levels were ≤5.9%. The inter-day consistency was assessed by running QC samples during each daily run. The coefficients of variation for quality control samples in both matrixes were ≤6.1%. The method has been utilized to support clinical pharmacokinetic studies.  相似文献   

14.
A sensitive high-performance liquid chromatographic (HPLC) method was developed for the determination of a benzonaphthazepine antipsychotic agent, SCH 39166, and its active metabolite, SCH 40853. The HPLC method required a single-step organic extraction at alkali pH followed by HPLC analysis utilizing a CN column with UV detection at 205 nm. The limit of quantitation was 1 ng/ml for SCH 39166 and 0.5 ng/ml for SCH 40853. The HPLC method was cross-validated with a previously reported GC method by the analysis of 73 plasma samples spiked with various concentrations of SCH 39166 and SCH 40853. The correlation coefficient was 0.9969 for SCH 39166 and 0.9984 for SCH 40853. Both GC and HPLC methods were used for the determination of plasma concentrations and yielded similar pharmacokinetic parameters for SCH 39166 and SCH 40853 in man following oral administration of SCH 39166 (100 mg).  相似文献   

15.
A method for determining concentration levels of ganaxolone in rat, monkey, dog and human plasma was validated in the range of 5–1500 ng/ml using a 200-μl plasma sample volume. This validation report describes the linearity, specificity, sensitivity, reproducibility, accuracy, recovery and stability of the analytical method. The inter-day C.V. ranged from 0.5 to 9.2%, intra-day C.V. from 0.7 to 8.8% and intra-day accuracy (mean absolute percentage difference) ranged from 0.0 to 14.0% for rat, monkey, dog and human plasma. The method was used for the routine analysis of ganaxolone in rat, monkey, dog and human plasma and summary of the pharmacokinetic data are presented.  相似文献   

16.
A new method was developed for determination of itopride in human serum by reversed phase high-performance liquid chromatography (HPLC) with fluorescence detection (excitation at 291 nm and emission at 342 nm). The method employed one-step extraction of itopride from serum matrix with a mixture of tert-butyl methyl ether and dichloromethane (70:30, v/v) using etoricoxib as an internal standard. Chromatographic separation was obtained within 12.0 min using a reverse phase YMC-Pack AM ODS column (250 mm x 4.6 mm, 5 microm) and an isocratic mobile phase constituting of a mixture of 0.05% tri-fluoro acetic acid in water and acetonitrile (75:25, v/v) flowing at a flow rate of 1.0 ml/min. The method was linear in the range of 14.0 ng/ml to 1000.0 ng/ml. The lower limit of quantitation (LLOQ) was 14.0 ng/ml. Average recovery of itopride and the internal standard from the biological matrix was more than 66.04 and 64.57%, respectively. The inter-day accuracy of the drug containing serum samples was more than 97.81% with a precision of 2.31-3.68%. The intra-day accuracy was 96.91% or more with a precision of 5.17-9.50%. Serum samples containing itopride were stable for 180.0 days at -70+/-5 degrees C and for 24.0 h at ambient temperature (25+/-5 degrees C). The method was successfully applied to the bioequivalence study of itopride in healthy, male human subjects.  相似文献   

17.
A reversed-phased liquid chromatography with tandem mass spectrometry (LC-MS/MS) method was developed and validated for quantitation of the total and unbound RO4929097, a γ-secretase inhibitor targeting Notch signaling, in human plasma. Sample preparation involved a liquid-liquid extraction with ethyl acetate. Chromatographic separation was achieved on a Waters X-Terra? MS C(18) column with an isocratic mobile phase consisting of methanol/0.45% formic acid in water (60:40, v/v) running at a flow rate of 0.2 ml/min for 6 min. The lower limits of quantitation (LLOQs) were 5 ng/ml for the total RO4929097 in plasma and 0.5 ng/ml for the unbound drug in phosphate buffer solution (PBS). Calibration curves were linear over RO4929097 concentration range of 5-2000 ng/ml in plasma for the total drug and 0.5-200 ng/ml in PBS for the unbound drug. The intra-day and inter-day accuracy and precision were within the generally accepted criteria for bioanalytical method (<15%). The method has been successfully employed to characterize the total and unbound plasma pharmacokinetics of RO4929097 after its oral administration in cancer patients.  相似文献   

18.
A solid-phase extraction (SPE) procedure was developed for the quantification of nalbuphine in a small volume (500 μl) of human plasma with subsequent assay by high-performance liquid chromatography (HPLC) and electrochemical detection using 6-monoacetylmorphine as internal standard. Plasma was extracted using Bond Elute certified extraction columns (LCR: 10 ml, 130 mg) after conditioning with methanol and 0.2 M Tris buffer (pH 8). Elution was performed with a CH2Cl2-isopropanol-NH4OH (79:20:, v/v). The organic phase was evaporated to dryness and resuspended in HPLC mobile phase containing 2% isopropanol. Linearity was assessed over the 5–100 ng/ml concentration range and a straight line passing through the origin was obtained. Experiments with spiked plasma samples resulted in recoveries of 95±5.4% and 98±6.2% for nalbuphine and 6-monoacetylmorphine, respectively. The optimal pH conditions for the SPE were found at pH 8. The intra-day coefficients of variation (C.V.) for 5, 40, and 100 ng/ml were 5.3, 3.0 and 2.3% (n=8) and the inter-day C.V.s were 7.7, 3.2 and 3.5% (n=10), respectively. The detection limit for 500 μl plasma sample was 0.02 ng/ml and the limit of quantification 0.1 ng/ml (C.V.=12.4%). The ease of the proposed method of analysis, as well as its high accuracy and sensitivity allow its application to pharmacokinetic studies. A preliminary kinetic profile of nalbuphine after rectal administration in a pediatric patient is presented.  相似文献   

19.
An HPLC assay was developed using three methods of plasma sample preparation in order to quantitate curcumin, the main constituent in the herbal dietary supplement turmeric. Each method involves simple and rapid processing of samples (either an ethyl acetate or chloroform extraction) with resulting different quantitation limits for curcumin. The assay was developed in an effort to quantify extremely low curcumin plasma concentrations observed in preliminary in vivo studies. The most sensitive assay can reliably detect concentrations down to 2.5 ng/ml. Plasma quantitation was precise and accurate based on both intra- and inter-day validations as indicated by low values for coefficients of variation and bias, respectively (< or =15%). The analytical validation was reproducible between different analysts. The resulting analytical method couples desired sensitivity with the ease of an isocratic system.  相似文献   

20.
A simple, specific and sensitive high-performance liquid chromatographic (HPLC) method was developed for the determination of rifampin in human plasma. Rifampin and sulindac (internal standard) are extracted from human plasma using a C2 Bond Elut extraction column. A 100-μl volume of 0.1 M HCl is added to the plasma before extraction to increase the retenction of the compounds on the extraction column. Methanol (1 ml) is used to elute the compounds and 0.5 ml of 3 mg/ml ascorbic acid in water is added to the final eluate to reduce the oxidation of rifampin. Separation is achieved by reversed-phase chromatography on a Zorbax Rx C8 column with a mobile phase composed of 0.05 M potassium dihydrogen phosphate-acetonitrile (55:45, v/v). Detection is by ultraviolet absorbance at 340 nm. The retention times of rifampin and internal standard are approximately 4.4 and 7.8 min, respectively. The assay is linear in concentration ranges of 50 to 35 000 ng/ml. The quantitation limit is 50 ng/ml. Both intra-day and inter-day accuracy and precision data showed good reproducibility.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号