首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 9 毫秒
1.
A rapid, rugged and fully automated method has been developed for the determination of tamoxifen and its major metabolites in plasma. The system is based upon an in-line extraction process combined with column switching to a coupled analytical column. The plasma sample is deproteinated by the addition of acetonitrile before injection onto a semi-permeable surface (SPS) cyano guard column (1.0 × 0.46 cm I.D.). After washing the guard column briefly with water, the sample is eluted with a mobile phase composed of 35% acetonitrile in 20 mM potassium phosphate buffer (pH 3). The eluent is directed through a cyano analytical column (25 × 0.46 cm I.D.) and a photochemical reactor where the analytes are converted to highly fluorescent phenanthrene derivatives. Tamoxifen, 4-hydroxytamoxifen, N-desdimethyltamoxifen, N-desmethyltamoxifen and tamoxifen-ol are eluted in that order at a flow-rate of 1.0 ml/min. The method has been validated for use in a clinical study utilizing tamoxifen in the treatment of recurrent cerebral astrocytomas.  相似文献   

2.
A fully automated narrowbore high-performance liquid chromatography method with column switching was developed for the simultaneous determination of sildenafil and its active metabolite UK-103,320 in human plasma samples without pre-purification. Diluted plasma sample (100 μl) was directly introduced onto a Capcell Pak MF Ph-1 column (20×4 mm I.D.) where primary separation occurred to remove proteins and concentrate target substances using 15% acetonitrile in 20 mM phosphate solution (pH 7). The drug molecules eluted from the MF Ph-1 column were focused in an intermediate column (35×2 mm I.D.) by a valve switching step. The substances enriched in the intermediate column were eluted and separated on a phenyl-hexyl column (100×2 mm I.D.) using 36% acetonitrile in 10 mM phosphate solution (pH 4.5) when the valve status was switched back. The method showed excellent sensitivity (detection limit of 10 ng/ml), good precision (RSD≤2.3%) and accuracy (bias: ±2.0%) and speed (total analysis time 17 min). The response was linear (r2≥0.999) over the concentration range 10–1000 ng/ml.  相似文献   

3.
A high-performance liquid chromatographic method was developed for the quantification of doxorubicin derived from PEGylated liposomal doxorubicin (Doxil) and its major metabolite in human plasma. This method utilizes Triton X-100 to disperse the liposome, followed by a protein precipitation step with 5-sulfosalicylic acid. Analytes in the resultant supernatant are separated on a Discovery RP amide C(16) column (250 x 3 mm I.D., 5 microm) using an isocratic elution with a mobile phase consisting of 0.05 M sodium acetate (pH 4.0) and acetonitrile (72:28). The retention times for doxorubicin and the internal standard daunorubicin were 4.8 and 10.1 min, respectively. The column eluate was monitored by UV-visible detection at 487 nm. The determination of doxorubicin was found to be linear in the range of 1.0 ng/mL to 25 microg/mL, with intra-day and inter-day coefficients of variation and percent error < or =10%. The recovery of doxorubicin from plasma was >69.3%, with a liposomal dispersion efficiency of >95.7%. Our analytical method for free and PEGylated doxorubicin in human plasma is rapid, avoids organic extractions, and maintains sensitivity for the parent compound and its major metabolite, doxorubicinol.  相似文献   

4.
Gemcitabine (dFdC) is a pyrimidine antimetabolite with broad spectrum activity against tumors. In this paper, a normal-phase high-performance liquid chromatographic method was developed for the determination of the parent drug (dFdC) and its metabolite (dFdU) in human plasma. The described sample preparation procedure for determination of dFdC and dFdU is rapid, sensitive, reproducible and simple. The linear regression equations obtained by least square regression method, were area under the curve=0.0371 concentration (ng ml(-1))+192.53 and 1.05.10(-4) concentration (ng ml(-1))-1.2693 for dFdC and dFdU, respectively. The assay for dFdC and dFdU described in the present report has been applied to plasma samples from a bladder cancer patient.  相似文献   

5.
6.
A simple and sensitive high-performance liquid chromatographic method for the simultaneous assay of amiodarone and desethylarniodarone in plasma, urine and tissues has been developed. The method for plasma samples and tissue samples after homogenizing with 50% ethanol, involves deproteinization with acetonitrile containing the internal standard followed by centrifugation and direct injection of the supernatant into the liquid chromatograph. The method for urine specimens includes extraction with a diisopropyl ether—acetonitrile (95:5, v/v) mixture at pH 7.0 using disposable Clin-Elut 1003 columns, followed by evaporation of the eluate, reconstitution of the residue in methanol—acetonitrile (1:2, v/v) mixture and injection into the chromatograph. Separation was obtained using a Radial-Pak C18 column operating in combination with a radial compression separation unit and a methanol–25% ammonia (99.3:0.7, v/v) mobile phase. A wavelength of 242 nm was used to monitor amiodarone, desethylamiodarone and the internal standard. The influence of the ammonia concentration in the mobile phase on the capacity factors of amiodarone, desethylamiodarone and two other potential metabolites, monoiodoamiodarone (L6355) and desiodoamiodarone (L3937) were investigated. Endogenous substances or a variety of drugs concomitantly used in amiodarone therapy did not interfere with the assay.The limit of sensitivity of the assay was 0.025 μg/ml with a precision of ± 17%. The inter- and intra-day coefficient of variation for replicate analyses of spiked plasma samples was less than 6%. This method has been demonstrated to be suitable for pharmacokinetic and metabolism studies of amiodarone in man.  相似文献   

7.
A sensitive and specific high-performance liquid chromatographic method for determination of the 2-chloroprocaine, local anesthetic of ester type, and its major metabolite 2-chloroaminobenzoic acid, has been developed and validated. A single-step extraction procedure is employed followed by high-performance liquid chromatographic separation using reversed-phase column and analysis using variable length UV detection. Lidocaine was used as internal standard for 2-chloroprocaine measurement and p-aminobenzoic acid was used as internal standard for 2-chloroaminobenzoic acid analysis. The analysis of spiked plasma demonstrated good accuracy and precision of the method with limit of detection 0.1 μg/ml for 2-chloroprocaine and 0.5 μg/ml for 2-chloroaminobenzoic acid. The method has been used for pharmacokinetic studies in laboratory animals.  相似文献   

8.
A rapid and sensitive high-performance liquid chromatographic method is described for the quantitative analysis of dipotassium clorazepate (CZP) and its major metabolite nordiazepam (ND) in fresh human and dog plasma. The method consists of two separate selective ND extractions from a plasma sample without and with conversion of all the CZP to ND. For quantitation, diazepam (DZP) is used as the internal standard. The chromatographic phase utilized in a reversed-phase Hibar® EC-RT analytical column prepacked with LiChrosolv RP-18 with a solvent system consisting of acetonitrile-0.05 M sodium acetate buffer, pH 5.0 (45:55). The UV absorbance is monitored at 225 nm using a variable-wave-length detector. The mean assay coefficient of variation over a concentration range of 20–400 ng per ml of plasma is less than 3% for the within-day precision. Recoveries of ND, DZP and CZP (as ND) are essentially quantitative at all levels investigated. The calibration curves of ND are rectilinear (r2 = 0.99) from the lower limit of sensitivity (2 ng/ml) to at least 2000 ng/ml in plasma. Applicability of the method to CZP and ND disposition studies in the anaesthetized mongrel dog is illustrated. When the two separate selective nordiazepam extractions from plasma cannot be performed immediately after blood sampling, an extrapolation kinetic method is suggested for the estimation of CZP concentration. In all previous in vivo studies, CZP has been determined only with gas-liquid chromatographic methods.  相似文献   

9.
It has been suggested that GTS-21 can improve the learning deficits and inhibit the neuro-degeneration in patients with Alzheimer's disease. This paper describes a reversed-phase high-performance liquid chromatographic assay with visible detection at 405 nm for determination of GTS-21 and its metabolite, 4-hydroxy-GTS-21 in rat plasma. The method uses solid-phase extraction with a Bond Elut C18 column. A quantitation limit of 1.0 ng/ml was achieved using 0.5 ml of rat plasma. In the validation study, the coefficients of variation and the relative errors of each compound were less than 10%. Also freeze-thaw and storage stability were confirmed. This method has proved to be applicable to the pharmacokinetic study of GTS-21 in rats.  相似文献   

10.
A rapid, selective, sensitive and reproducible HPLC with recutive electrochemical detection for quantitatvie determination of artemether (ART) and its plasma metabolite, dihydroartemisinin (DHA: and β isomers) in plasma is described. The procedure involved the extraction of ART, DHA and the internal standard, artemisinin (ARN) with dichloromethane-tert.-methylbutyl ether (1:1, v/v) or n-butyl chloride-ethyl acetate (9:1, v/v). Chromatographic separation was performed with a mobile phase of acetonitrile-water (20:80, v/v) containing 0.1 M acetic acid pH 5.0, running through a μBondapak CN column. The method was capable of separating the two isomeric forms of DHA (, β). The retention times of -DHA, β-DHA, ARN and ART were 4.6, 5.9, 7.9 and 9.6 min, respectively. Validation of the assay method was performed using both extraction systems. The two extraction systems produced comparable recoveries of the various analytes. The average recoveries of ART, DHA and ARN over the concentration range 80–640 ng/ml were 86–93%. The coefficients of variation were below 10% for all three drugs (ART, -DHA, ARN). The minimum detectable concentrations for ART and -DHA in spiked plasma samples were 5 and 3 ng/ml, respectively. The method was found to be suitable for use in clinical pharmacokinetic study.  相似文献   

11.
We report a quantitative assay of 5-fluorouracil (FU) and its metabolite, 5-fluorodihydrouracil (FDHU) in human urine by used a column-switching high-performance liquid chromatographic method. The analyses were carried out using a molecular exclusion column for sample purification, and a cation-exchange column for separation. Each sample required only 40 min to analyze, and required no preparation other than filtration. Linearity was verified up to 1000 nmol/ml (r>0.993). The recovery of FU was 96–101%; recovery of FDHU was 96–105%. The imprecision (RSD) for FU (10–100 nmol/ml) was <1.5%, same-day (n=5), and <1.8%, day-to-day (n=5). The imprecision (RSD) for FDHU (10–100 nmol/ml) was <3.2%, same-day (n=5), and <4.0%, day-to-day (n=5). The detection limits were, respectively, 0.1 nmol/ml. We measured FU and FDHU in urine of seven cancer patients after oral administration of FU. The cumulative quantity ratio of the FDHU and FU (FDHU/FU) excreted in their urine within 120 min after FU administration was a constant value in all seven patients. Based on these results, we believe that our method provides a useful tool for evaluating FU metabolism.  相似文献   

12.
A high-performance liquid chromatography (HPLC) procedure for the simultaneous determination of quinapril and its active metabolite quinaprilat in human plasma samples is described. A one-step solid-phase extraction (SPE) with C18 cartridges was coupled with a reversed-phase HPLC system. The system requires two mobile phases composed of tetrabutyl ammonium hydrogensulfate (10 mM adjusted to pH 7)-acetonitrile (62:38, v/v) for quinapril, and (25:75, v/v) for quinaprilat elution through a C18 Symmetry column and detection at a wavelength of 215 nm. Calibration curves were linear over the ranges 20 to 1,000 ng/ml for quinaprilat and 10 to 500 for quinapril. The limits of quantification were 20 and 10 ng/ml for quinaprilat and quinapril, respectively. Extraction recoveries were higher than 90% for quinapril and 80% for quinaprilat. This method has been successfully applied to a bioequivalence study of quinapril in healthy subjects.  相似文献   

13.
The simultaneous determination of methadone (Mtd) enantiomers and its major metabolite, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), in human urine and serum by enantioselective HPLC using a new Cyclobond I-2000 RSP column is described. After alkaline extraction from urine or serum with estazolam as an internal standard, Mtd enantiomers and its metabolite (EDDP) are separated on the previous column with reversed-mobile phase and detected at 210 nm. Peak resolutions are about 2.0 for Mtd enantiomers. The relative standard deviations (R.S.D.) of Mtd and EDDP standards are between 0.5 and 4.5%. Most drugs of abuse are shown not to interfere with this technique. The method has been applied to study levels of each Mtd enantiomer and of its racemic metabolite in urine and serum of patients under maintenance treatment for opiate dependence. In urine, R-(−)-Mtd levels are always higher (about 2±0.5-fold_ than those of S-(+)-Mtd and in most cases, metabolite concentrations are greater than those of global Mtd enantiomers. However, the R-(−) enantiomer levels of residual drug in serum of some patients were lower than those of its antipode. This method is suitable for pharmacokinetic and toxicological studies of Mtd enantiomers and its major metabolite in biological fluids.  相似文献   

14.
Extensive modification of an existing high-performance liquid chromatography assay for acebutolol and its major metabolite has markedly improved chromatographic stability eliminating the previous need for frequent adjustment of the eluent composition to accommodate continuous loss of column retention. The eluents now used and avoidance of the requirement for elevated column temperature may be significant factors in the ability to maintain column life over 8 months of continuous use with little decrease in retention As a result of the improved chromatographic stability full advantage can now be taken of automatic injection devices for the unattended processing of large numbers of samples. A significant modification of the work-up of blood samples has improved precision of the assay in whole blood. Nevertheless, it is recommended that plasma samples rather than whole blood be analyzed, since the plasma assay is faster and still more precise.  相似文献   

15.
An automated method, based on column-switching reversed-phase high-performance liquid chromatography, has been developed for the determination of a major metabolite of tipredane in rat urine. Samples are injected directly onto a cyanopropyl extraction column. The portion of eluate containing the metabolite is switched, via an injection loop, onto an octadecylsilane analytical column. The limit of quantification of the method was 25 ng/ml for a 20 μl injection volume of urine. The intra-assay precision (0.7–4.8%) and accuracy (94–105%), and the inter-assay precision (2.7–12.6%) and accuracy (94–105%), were acceptable. The analyte was found to be stable in rat urine when stored at room temperature for six days, in a freezer at or below −20°C for twelve weeks, and when the samples were subjected to two freeze–thaw cycles. No significant interference was observed from tipredane and its major human metabolites, or urine constituents in male and female rats. The method was successfully used to analyse samples from a long-term toxicology study.  相似文献   

16.
A novel, highly sensitive method was developed for simultaneous determination of tramadol and its main active metabolite O-demethyltramadol (ODMT) in rat plasma. The method involves a single-step extraction procedure and a specific determination by high-performance liquid chromatography with electrochemical detection, using an ethoxy analogue of tramadol (L-233) as internal standard. The dual-electrode detector was operated in the oxidation-screening mode. Absolute recoveries of tramadol and ODMT were about 80%. Calibration curves were linear over a concentration range of 10–1000 ng/ml for ODMT and 10–10 000 ng/ml for tramadol with intra- and inter-day coefficients of variation not exceeding 10% and 15%, respectively. The limit of quantification for tramadol and ODMT was lower than 15 ng/ml and 10 ng/ml using 100 μl of plasma, respectively. The described method allows an adequate characterization of the plasma vs. time profiles for both compounds.  相似文献   

17.
A simple and selective assay for the determination of the alkylating cyclophosphamide metabolite phosphoramide mustard (PM) in plasma was developed and validated. PM was determined after derivatisation by high-performance liquid chromatography (HPLC) with ultraviolet detection at 276 nm. Sample pre-treatment consisted of derivatisation of PM with diethyldithiocarbamate (DDTC) at 70°C for 10 min, followed by extraction with acetonitrile in the presence of 0.7 M sodium chloride. Phase separation occurred due to the high salt content of the aqueous phase. The HPLC system consisted of a C8 column with acetonitrile–0.025 M potassium phosphate buffer, pH 8.0, (32:68, v/v) as the mobile phase. The entire sample handling procedure, from collection at the clinical ward until analysis in the laboratory, was optimised and validated. Calibration curves were linear from 50 to 10 000 ng/ml. The lower limit of quantification and the limit of detection (using a signal-to-noise ratio of 3) were 50 and 40 ng/ml, respectively, using 500 μl of plasma. Within-day and between-day precisions were below 11% over the entire concentration range and the accuracies were between 100 and 106%. PM was found to be stable at −30°C for at least 10 weeks both in plasma and as a DDTC-derivative in a dry sample. A pharmacokinetic pilot study in two patients receiving 1000 mg/m2 CP in a 1-h infusion demonstrated the applicability of the assay.  相似文献   

18.
Methods are described for the fluorometric determination of plasma adenosine concentrations, using HPLC. Plasma obtained from blood of dogs treated with erythro-(2-hydroxy-3-nonyl)adenine hydrochloride and dipyridamole was deproteinized with perchloric acid and the neutralized sample was put sequentially onto a SepPak C18 and boronic acid affinity column. Subsequently, adenosine in the final elution was converted to 1,N6-ethenoadenosine and was quantitated by HPLC with a fluorescence detector. The percentage recovery of adenosine added to the deproteinized plasma was nearly 100%. In the adenosine deaminase treated plasma, the increase in adenosine concentration of even 4 nM can be accurately determined. The control renal venous plasma concentrations of adenosine in anesthetized dogs were 19.9 +/- 1.9 nM, a significantly higher value than the corresponding arterial concentrations (12.7 +/- 1.1 nM), thereby suggesting the renal release of adenosine. This release was markedly enhanced following the removal of the renal arterial occlusion. Thus, taken together with the in vivo results, the present method is sensitive, hence most useful for the determination of plasma adenosine concentrations.  相似文献   

19.
A rapid, sensitive and specific high-performance liquid chromatographic (HPLC) assay was developed for the determination of estramustine and its 17-keto metabolite in plasma. The assay involves extraction of the compounds into hexane from plasma buffered to pH 9.0, the residue obtained by evaporation of the hexane extract is dissolved in the mobile phase hexane—ethanol (92.5:7.5) with HPLC analysis performed on a 5-μm silica gel column using a fluorescence detector with excitation at 195 nm and emission at wavelengths greater than 250 nm. The overall recoveries and limits of sensitivity for estramustine and the 17-keto metabolite are 74.7% and 40 ng/ml of plasma and 85.1% and 50 ng/ml of plasma, respectively. The method was used to obtain plasma concentration—time profiles in three subjects with prostatic cancer following oral administration of a single 7 mg/kg dose of estramustine phosphate.  相似文献   

20.
A highly sensitive and selective high-performance liquid chromatographic assay has been developed for the separation and quantitation of tolmetin and its major metabolite in human biological fluids, viz. plasma, urine and synovial fluid. Analysis of plasma and synovial fluid required only 0.5 ml of the sample. The sample was washed with diethyl ether and extracted with diethyl ether—chloroform (2:1). The extracted compounds were injected onto a reversed-phase column (RP-2) and absorbance was measured at 313 nm. The standard curves in plasma were found to be linear for both tolmetin and the metabolite at concentrations from 0.04 to 10.0 μg/ml. Urine samples (0.5 ml) were diluted (1:1) with methanol containing the internal standard and were directly injected onto the reversed-phase (RP-2) column. Standard curves of tolmetin and metabolite in urine were linear in the range 5–300 μg/ml. Serum and synovial fluid concentrations of tolmetin and its metabolite in patients receiving multiple doses of tolmetin sodium were determined using the assay procedure.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏