首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A mathematical model has been implemented for evaluation of methods for estimating breath-to-breath alveolar gas exchange during exercise in humans. This model includes a homogeneous alveolar gas exchange compartment, a dead space compartment, and tissue spaces for CO2 (alveolar and dead space). The dead space compartment includes a mixing portion surrounded by tissue and an unmixed (slug flow) portion which is partitioned between anatomical and apparatus contributions. A random sinusoidal flow pattern generates a breath-to-breath variation in pulmonary stores. The Auchincloss algorithm for estimating alveolar gas exchange (Auchincloss et al., J. Appl. Physiol. 21: 810-818, 1966) was applied to the model, and the results were compared with the simulated gas exchange. This comparison indicates that a compensation for changes in pulmonary stores must include factors for alveolar gas concentration change as well as alveolar volume change and thus implies the use of end-tidal measurements. Although this algorithm yields reasonable estimates of breath-to-breath alveolar gas exchange, it does not yield a "true" indirect measurement because of inherent error in the estimation of a homogeneous alveolar gas concentration at the end of expiration.  相似文献   

2.
Using implanted radiopaque markers, Hubmayr et al. (J. Appl. Physiol. 54: 1048-1056, 1983) and Olson et al. (J. Appl. Physiol. 57: 1710-1714, 1984) detected a variability in the volume changes of regions defined by the markers in intact and excised dog lungs, respectively. In dogs lying prone and in excised lobes, there is virtually no large-scale spatial organization of the variability. We interpret these data as evidence of an intrinsic heterogeneity of parenchymal expansion. The effect of variability of parenchymal expansion on gas mixing is calculated. From a statistical model, we infer that the variability of volume changes observed by Olson et al. is a result of an underlying variability with a larger magnitude at a smaller scale and that the variability at the smaller scale is large enough to explain the inefficiency of mixing observed in single-breath oxygen tests on excised dog lobes.  相似文献   

3.
A method is described for breath-by-breath measurement of alveolar gas exchange corrected for changes of lung gas stores. In practice, the subject inspires from a spirometer, and each expired tidal volume is collected into a rubber bag placed inside a rigid box connected to the same spirometer. During the inspiration following any given expiration the bag is emptied by a vacuum pump. A computer monitors inspiratory and expiratory tidal volumes, drives four solenoid valves allowing appropriate operation of the system, and memorizes end-tidal gas fractions as well as mixed expired gas composition analyzed by mass spectrometer. Thus all variables for calculating alveolar gas exchange, based on the theory developed by Auchincloss et al. (J. Appl. Physiol. 21: 810-818, 1966), are obtained on a single-breath basis. Mean resting and steady-state exercise gas exchange data are equal to those obtained by conventional open-circuit measurements. Breathing rates up to 30 X min-1 can be followed. The breath-to-breath variability of O2 uptake at the alveolar level is less (25-35%) than that measured at the mouth as the difference between the inspired and expired volumes, both at rest and during exercise up to 0.7 of maximum O2 consumption.  相似文献   

4.
Cardiac output (Q) was estimated in supine rest and in upright cycling at several work rates up to 200 W in five male and one female subjects. At least four repetitions of both the CO2-rebreathing plateau method (Collier, J. Appl. Physiol. 9:25-29, 1956) and the Kim et al. (J. Appl. Physiol. 21: 1338-1344, 1966) single-breath method were performed at each work rate, in a steady state of O2 consumption and heart rate. At supine rest and low work rates, estimates of Q were similar by the two methods. However, at higher work rates, the single-breath method significantly (P less than 0.05) underestimated the value obtained by CO2 rebreathing. The reason for the difference in estimates of Q by the two methods was traced to the determination of arterial partial pressure of CO2 (PaCO2) and mixed venous partial pressure of CO2 (PvCO2). The estimate of PaCO2 from the single-breath method was approximately 88.5% of the estimate from end-tidal PCO2 used with the rebreathing method (P less than 0.001). The oxygenated PvCO2 calculated from the single-breath Q averaged approximately 92.5% of the PvCO2 from CO2 rebreathing (P less than 0.0001). The difference in estimates of Q was not eliminated by using a logarithmic form of the CO2 dissociation curve with the single-breath method.  相似文献   

5.
In 1949, Fowler (J. Appl. Physiol. 2: 283-299) advocated calculation of a "dilution index" from data of the alveolar plateau of single-breath tests; the calculation provides an estimate of the dilution of resident gas in the lung that gave rise to the observed concentrations. In this communication, we show that the calculation can be applied to conventional single-breath tests where O2 is inhaled by air-breathing persons, and we illustrate the principle with vital capacity breaths of a mixture that contained a low concentration of neon. The dilution was approximately 3:1 in young subjects (20-30 yr), as if a vital capacity of 6 liters were mixed with a residual volume of 2 liters. The dilution was less, 2:1, in older subjects (56 yr) and tended to become as low as 1:1 during emptying of the closing volume. In addition to being more informative, the dilution index format allows common sense comparison of alveolar plateau levels and slopes when single-breath tests are done by various methods.  相似文献   

6.
Both interregional and intraregional mechanisms may cause changes in N2 concentration of expired gas during the phases of the single-breath O2 test (SBO2) that follow dead-space washout. To evaluate the possible importance of each mechanism, we performed the SBO2 in excised canine lungs that were first suspended in air and then immersed in stable foams that simulated the vertical gradient of pleural pressure. The lungs were deflated at constant submaximal flows. The slope of phase III diminished with increasing expiratory flow and increased with foam immersion. The onset of phase IV depended on flow, and a terminal decrease in N2 concentration (phase V) was often observed. Simultaneously measured estimates of regional flows and volumes (J. Appl. Physiol. 65: 1764-1774, 1988) were used to further interpret these results. The onset of phase IV at flows greater than quasi-static signified the onset of flow limitation of dependent regions. The onset of phase V corresponded to flow limitation of nondependent regions.  相似文献   

7.
The solubility of Freon 22 in human blood and lung tissue was determined using the chromatographic method of Wagner et al. (J. Appl. Physiol. 36: 600-605, 1974). In normal human blood, the mean Bunsen coefficient of solubility (alpha B) was 0.804 cm3 STPD.cm-3.ATA-1 at 37 degrees C. It increased with hematocrit (Hct) according to the equation alpha B = 0.274 Hct + 0.691. Tissue homogenates were prepared from macroscopically normal lung pieces obtained at thoracotomy from eight patients undergoing resection for lung carcinoma. The Bunsen solubility coefficients were 0.537 +/- 0.068 and 0.635 +/- 0.091 in washed and unwashed lung, respectively. These values can be used in the determination of both cardiac output and pulmonary tissue volume in humans by use of the rebreathing technique.  相似文献   

8.
The forced oscillation technique according to Làndsér et al. (J. Appl. Physiol. 41:101-106, 1976) was modified for use in infants. Adaptations, including a flexible tube to connect the infant to the measuring system and a bias flow to avoid rebreathing, did not influence impedance values. The linearity of the respiratory system was assessed and confirmed by 1) applying pseudo-random noise oscillations at three different amplitudes to 7 infants and 2) comparing in 12 infants impedance values obtained with pseudo-random noise and with sinusoidal oscillations at 12 and 32 Hz. Intersubject variability, averaged for all frequencies, was 6%. In 17 infants the relative error (+/- SD) between two series of five measurements within a time interval of 15 min was 0.5 +/- 5.7%. No statistically significant difference was found between impedance values before and after repositioning of the infant's head, whereas rotation resulted in a decrease in resistance and no effect on reactance. Our results indicate that the infant-adapted forced pseudo-random noise oscillation technique has the potential to give valuable information about ventilatory lung function in infants.  相似文献   

9.
Perfusion of isolated sheep lungs with homologous blood caused pulmonary hypertension and edema that was not altered by depletion of perfusate polymorphonuclear (PMN) leukocytes (D. B. Pearse et al., J. Appl. Physiol. 66: 1287-1296, 1989). The purpose of this study was to evaluate the role of resident PMN leukocytes in this injury. First, we quantified the content and activation of lung PMN leukocytes before and during perfusion of eight isolated sheep lungs with a constant flow (100 ml.kg-1.min-1) of homologous blood. From measurements of myeloperoxidase (MPO) activity, we estimated that the lungs contained 1.2 x 10(10) PMN leukocytes, which explained why the lung PMN leukocyte content, measured by MPO activity and histological techniques, did not increase significantly with perfusion, despite complete sequestration of 2.0 x 10(9) PMN leukocytes from the perfusate. MPO activities in perfusate and lymph supernatants did not increase during perfusion, suggesting that lung PMN leukocytes were not activated. Second, we perfused lungs from 6 mechlorethamine-treated and 6 hydroxyurea-treated sheep with homologous leukopenic blood and compared them with 11 normal lungs perfused similarly. Despite marked reductions in lung PMN leukocyte concentration, there were no differences in pulmonary arterial pressure, lymph flow, or reservoir weight between groups. Extravascular lung water was greater in both groups of leukopenic lungs. These results suggest that resident PMN leukocytes did not contribute to lung injury in this model.  相似文献   

10.
"Distribution of blood flow in isolated lung; relation to vascular and alveolar pressures" by J. B. West, C. T. Dollery, and A. Naimark (J Appl Physiol 19: 713-724, 1964) is a classic paper, although it has not yet been included in the Essays on the American Physiological Society Classic Papers Project (http://www.the-aps.org/publications/classics/). This is the paper that originally described the "zones of the lung." The final figure in the paper, which synthesizes the results and discussion, is now seen in most textbooks of physiology or respiratory physiology. The paper is also a model of clear, concise writing. The paper and its final figure can be used to teach or review a number of physiological concepts. These include the effects of gravity on pulmonary blood flow and pulmonary vascular resistance; recruitment and distention of pulmonary vessels; the importance of the transmural pressure on the diameter of collapsible distensible vessels; the Starling resistor; the interplay of the pulmonary artery, pulmonary vein, and alveolar pressures; and the vascular waterfall. In addition, the figure can be used to generate discovery learning and discussion of several physiological or pathophysiological effects on pulmonary vascular resistance and the distribution of pulmonary blood flow.  相似文献   

11.
Previous work by Lehnert et al. (J. Appl. Physiol. 53:483-489, 1982) has demonstrated that adequate alveolar ventilation can be maintained during apnea in anesthetized dogs by delivering a continuous stream of inspired ventilation through cannulas aimed down the main-stem bronchi. Because an asymmetric distribution of ventilation might introduce ventilation-perfusion (VA/Q) inequality, we compared gas exchange efficiency in nine anesthetized and paralyzed dogs during constant-flow ventilation (CFV) and conventional ventilation (intermittent positive-pressure ventilation, IPPV). Gas exchange was assessed using the multiple inert gas elimination technique. During CFV at 3 l X kg-1 X min-1, lung volume, retention-excretion differences (R-E*) for low- and medium-solubility gases, and the log standard deviation of blood flow (log SD Q) increased, compared with the findings during IPPV. Reducing CFV flow rate to 1 l X kg-1 X min-1 at constant lung volume improved R-E* and log SD Q, but significant VA/Q inequality compared with that at IPPV remained and arterial PCO2 rose. Comparison of IPPV and CFV at the same mean lung volume showed a similar reversible deterioration in gas exchange efficiency during CFV. We conclude that CFV causes significant VA/Q inequality which may be due to nonuniform ventilation distribution and a redistribution of pulmonary blood flow.  相似文献   

12.
The single-breath method of determining pulmonary blood flow is a simple technique involving no inert gas or special maneuvers such as rebreathing or breath holding. The use of this elegant technique has been limited, however, largely because of questions regarding its accuracy. Previous analyses of the method have indicated that large errors in the estimated blood flow could result if data reduction is not handled carefully. In addition, an uncertain amount of error is introduced, if the CO2 retained by the lung tissue while measurements are being made is not taken into account in the calculations. This paper presents a rigorous approach for estimating the pulmonary blood flow by the single-breath method, which would minimize considerably the effects of measurement errors and would also allow for possible CO2 absorption by the lung tissue. It is based on the exact solution of the underlying equations that describe the dynamics of gas exchange in the lung. The analytic solution provides insight into the difficulties involved in extracting the desired information from the experimental data.  相似文献   

13.
Low Reynolds number airflow in the pulmonary acinus and aerosol particle kinetics therein are significantly conditioned by the nature of the tidal motion of alveolar duct geometry. At least two components of the ductal structure are known to exhibit stress-strain hysteresis: smooth muscle within the alveolar entrance rings, and surfactant at the air-tissue interface. We hypothesize that the geometric hysteresis of the alveolar duct is largely determined by the interaction of the amount of smooth muscle and connective tissue in ductal rings, septal tissue properties, and surface tension-surface area characteristics of surfactant. To test this hypothesis, we have extended the well-known structural model of the alveolar duct by Wilson and Bachofen (1982, "A Model for Mechanical Structure of the Alveolar Duct," J. Appl. Physiol. 52(4), pp. 1064-1070) by adding realistic elastic and hysteretic properties of (1) the alveolar entrance ring, (2) septal tissue, and (3) surfactant. With realistic values for tissue and surface properties, we conclude that: (1) there is a significant, and underappreciated, amount of geometric hysteresis in alveolar ductal architecture; and (2) the contribution of smooth muscle and surfactant to geometric hysteresis are of opposite senses, tending toward cancellation. Quantitatively, the geometric hysteresis found experimentally by Miki et al. (1993, "Geometric Hysteresis in Pulmonary Surface-to-Volume Ratio during Tidal Breathing," J. Appl. Physiol. 75(4), pp. 1630-1636) is consistent with little or no smooth muscle tone in anesthetized rabbits in control conditions, and with substantial smooth muscle activation following methacholine challenge. The observed local hysteretic boundary motion of the acinar duct would result in irreversible acinar flow fields, which might be important mechanistic contributors to aerosol mixing and deposition deep in the lung.  相似文献   

14.
Factors both intrinsic and extrinsic to the lung may cause inhomogeneity of alveolar pressures during deflation. Wilson et al. (J. Appl. Physiol. 59: 1924-1928, 1985) predicted that any such inhomogeneity would be limited by interdependence of regional expiratory flows. To test this hypothesis and to explore how the pleural pressure gradient might affect inhomogeneity of alveolar pressures, we deflated at submaximal flows excised canine lobes that first were suspended in air and then were immersed in foams that simulated the vertical gradient of pleural pressure. Interregional inhomogeneity of regional transpulmonary pressures was measured with use of an alveolar capsule technique. Flow-dependent inhomogeneity of alveolar pressures was present, with differences in alveolar pressure quickly relaxing to a constant limiting value at each flow. Foam immersion increased inhomogeneity at a given flow. We conclude that factors intrinsic to the lung cause significant inhomogeneity of alveolar pressures at submaximal expiratory flows and that this inhomogeneity is enhanced by the extrinsic gradient of pleural pressure. These observations are consistent with the interdependence of flow proposed by Wilson et al.  相似文献   

15.
In a model of increased hydrostatic pressure pulmonary edema Parker et al. (J. Appl. Physiol.: Respirat. Environ. Exercise Physiol. 44: 267-276, 1978) demonstrated that alveolar pressure in occluded fluid-filled lung segments was determined primarily by interstitial fluid pressure. Alveolar pressure was subatmospheric at base line and rose with time as hydrostatic pressure was increased and pulmonary edema developed. To further test the hypothesis that fluid-filled alveolar pressure is determined by interstitial pressure we produced permeability pulmonary edema-constant hydrostatic pressure. After intravenous injection of oleic acid in dogs (0.01 mg/kg) the alveolar pressure rose from -6.85 +/- 0.8 to +4.60 +/- 2.28 Torr (P less than 0.001) after 1 h and +6.68 +/- 2.67 Torr (P less than 0.01) after 3 h. This rise in alveolar fluid pressure coincided with the onset of pulmonary edema. Our experiments demonstrate that during permeability pulmonary edema with constant capillary hydrostatic pressures, as with hemodynamic edema, alveolar pressure of fluid-filled segments seems to be determined by interstitial pressures.  相似文献   

16.
A model for hypoxic constriction of the pulmonary circulation   总被引:1,自引:0,他引:1  
The detailed anatomic and biodynamic data provided for the cat lung by Zhuang et al. (J. Appl. Physiol. 55: 1341-1348, 1983) allowed pressure-flow curves for the normal lung to be generated. This model has been modified to permit the stimulation of the pressure and flow distribution effects of hypoxic pulmonary vasoconstriction for a two-compartment lung and generalized to allow comparison with the experimental results from dogs (and probably other species). Hypoxic pulmonary vasoconstriction is simulated by reduction of the initial diameter of the smallest six orders of pulmonary arteries. Expressions are presented that relate the alveolar and mixed-venous O2 tensions to a graded constriction of these vessels. In addition, the diameter of the capillary sheet and the six small arteries is defined with a maximum diameter at a transmural pressure of 20 cmH2O. Pressure-flow curves are derived for any combination of alveolar and mixed-venous O2 tension, alveolar and pleural pressure, left atrial pressure, and hematocrit. The two-compartment model is solved by an iterative procedure to identify the distribution of the flow and the resulting pulmonary arterial pressure when the compartments differ by size, hypoxic constriction, or other imposed conditions. The results of the model are compared with those from a variety of experimental preparations. It is concluded that the model is useful for identifying the quantitative causes of changes in the response to hypoxic pulmonary vasoconstriction and for the exploration of the functional influence of mechanical properties of the vasculature.  相似文献   

17.
Simultaneously measured helium (He) and sulfur hexafluoride (SF6) single-breath washout was studied in 16 anesthetized paralyzed dogs ventilated with a special hydraulically operated ventilatory servo system. After equilibration of lung gas with 1% He and 1% SF6, the maneuver consisting of inspiration of a test gas-free mixture at constant rate (VI), a variable time of breath holding, and an expiration at constant rate (VE), was performed. Fractional concentrations of He and SF6, recorded against expired volume, were analyzed in terms of slope of the alveolar plateau (S) and series (Fowler) dead space (VD). In control conditions (VI = 0.5 l/s, VE = 0.1 l/s) S was about 10% of alveolar-to-inspired concentration difference per liter expirate both for He and SF6. Both SHe and SSF6 were inversely related to VI and VE, the relative changes being more pronounced with varying VE. SHe/SSF6 was higher or lower than unity depending on VI and VE. Both SHe and SSF6 decreased with increasing preinspiratory lung volume. Breath holding up to 10 s slightly decreased SHe and SSF6 while SHe/SSF6 was unchanged. The contribution of continuing gas exchange to S assessed from comparative measurements using the reversed (single breath washin) technique ranged from 6 to 23% in the various conditions. The VDHe/VDSF6 ratio was 0.84 and was little affected in the various settings. Results indicate that the substantial alveolar gas inhomogeneity in the dog lung and the mechanism accounting for S are little diffusion dependent. By exclusion sequential filling and emptying of lung units is believed to constitute the most important mechanism responsible for the sloping alveolar plateau.  相似文献   

18.
Distributions of pulmonary blood flow per unit lung volume were measured with subjects in the prone, supine, and sitting positions by means of radionuclide-computed tomography of intravenously administered 99mTc-labeled macroaggregates of human serum albumin. The blood flow was greater in the direction of gravity in all 31 subjects except one with severe mitral valve stenosis. With the subject in a sitting position, four different types of distribution were distinguished. One type had a three-zonal blood flow distribution as previously reported by West and co-workers (J. Appl. Physiol. 19: 713-724, 1964). Pulmonary arterial pressure and venous pressure estimated from this model showed reasonable agreement with pulmonary arterial pressure and capillary wedge pressure measured by Swan-Ganz catheter in 17 supine patients and in 2 sitting patients. The method makes possible noninvasive assessment of pulmonary vascular pressures.  相似文献   

19.
Modeling of respiratory system impedances in dogs   总被引:1,自引:0,他引:1  
Mechanical impedances between 4 and 64 Hz of the respiratory system in dogs have been reported (A.C. Jackson et al. J. Appl. Physiol. 57: 34-39, 1984) previously by this laboratory. It was observed that resistance (the real part of impedance) decreased slightly with frequency between 4 and 22 Hz then increased considerably with frequency above 22 Hz. In the current study, these impedance data were analyzed using nonlinear regression analysis incorporating several different lumped linear element models. The five-element model of Eyles and Pimmel (IEEE Trans. Biomed. Eng. 28: 313-317, 1981) could only fit data where resistance decreased with frequency. However, when the model was applied to these data the returned parameter estimates were not physiologically realistic. Over the entire frequency range, a significantly improved fit was obtained with the six-element model of DuBois et al. (J. Appl. Physiol. 8: 587-594, 1956), since it could follow the predominate frequency-dependent characteristic that was the increase in resistance. The resulting parameter estimates suggested that the shunt compliance represents alveolar gas compressibility, the central branch represents airways, and the peripheral branch represents lung and chest wall tissues. This six-element model could not fit, with the same set of parameter values, both the frequency-dependent decrease in Rrs and the frequency-dependent increase in resistance. A nine-element model recently proposed by Peslin et al. (J. Appl. Physiol. 39: 523-534, 1975) was capable of fitting both the frequency-dependent decrease and the frequency-dependent increase in resistance. However, the data only between 4 and 64 Hz was not sufficient to consistently determine unique values for all nine parameters.  相似文献   

20.
Pressure-volume characteristics of the lung have been thought to be due primarily to the properties of the network of alveolar septa. However, Hajji et al. (J. Appl. Physiol.: Respirat . Environ. Exercise Physiol. 47: 175-181, 1979) attributed a substantial role to the visceral pleura. Seeking a structural explanation for this result, we compared the relative amounts of collagen fibrils and elastin fibers in the visceral pleura and alveolar parenchyma using stereological measurements in five canine lobes. We found about one-fifth as much collagen and one-tenth as much elastin in the pleura as in the alveolar parenchyma. This structural result confirms the functional conclusions of Hajji et al. We argue that such a substantial structure is not needed for protection against overinflation but may have to do with stabilization of lobe shape or handling of frictional forces.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号