首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Patients suffering from chronic obstructive pulmonary diseases, frequently exhibit expiratory airflow limitation. We propose a mathematical model describing the mechanical behavior of the ventilated respiratory system. This model has to simulate applied positive end-expiratory pressure (PEEP) effects during expiration, a process used by clinicians to improve airflow. The proposed model consists of a nonlinear two-compartment system. One of the compartments represents the collapsible airways and mimics its dynamic compression, the other represents the lung and chest wall compartment. For all clinical conditions tested (n=16), the mathematical model simulates the removal of expiratory airflow limitation at PEEP lower than 70–80% of intrinsic end-expiratory pressure (PEEPi), i.e. the end-expiratory alveolar pressure (PAet) without PEEP. It also shows the presence of an optimal PEEP. The optimal PEEP contributes to decrease PAet from 7.4 ± 0.9 (SD) to 5.4 ± 0.9 hPa (p < 0.0001; mild flow limitation) and from 11.8 ± 1.1 to 7.8 ± 0.7 hPa (p < 0.0001; severe flow limitation). Resistance of the collapsible compartment is decreased from 53 ± 7 to 8.2 ± 5.9 hPa.L–1.s (p < 0.0001; mild flow limitation) and from 80 ± 11 to 6.9 ± 5.4 hPa.L–1.s (p < 0.0001; severe flow limitation). This simplistic mathematical model gives a plausible explanation of the expiratory airflow limitation removal with PEEP and a rationale to the practice of PEEP application to airflow limited patients.  相似文献   

2.
Positive end-expiratory pressure (PEEP) has generally been withheld from the treatment of patients with chronic airflow obstruction (CAO), in view of the risk of hyperinflation and lack of documented benefit. We studied 10 mechanically ventilated patients with exacerbated CAO and air trapping to determine the impact of PEEP on lung mechanics, alveolar pressure, and the work of breathing. PEEP levels of 5 and 10 cmH2O were applied to patients whose end-expiratory alveolar pressures were documented to be positive when breathing against ambient pressure (the auto-PEEP effect). All patients were studied under two conditions: every breath machine assisted (AMV) and every breath machine controlled (paralyzed, CMV). PEEP improved expiratory resistance without substantially increasing peak static pressure. Inspiratory resistance remained unchanged. The difference between the end-expiratory values of alveolar and central airway pressure narrowed as PEEP increased. Adding PEEP improved the effective triggering sensitivity of the ventilator, diminished ventilatory drive, and reduced the mechanical work of breathing during the machine-assisted ventilatory cycle. Our results indicate that low levels of PEEP may improve lung mechanics and reduce the effort required of mechanically ventilated patients with severe airflow obstruction, without substantially increasing the hazards of hyperinflation.  相似文献   

3.
Humans produce exhaled breath particles (EBPs) during various breath activities, such as normal breathing, coughing, talking, and sneezing. Airborne transmission risk exists when EBPs have attached pathogens. Until recently, few investigations had evaluated the size and concentration distributions of EBPs from mechanically ventilated patients with different ventilation mode settings. This study thus broke new ground by not only evaluating the size concentration distributions of EBPs in mechanically ventilated patients, but also investigating the relationship between EBP level and positive expiratory end airway pressure (PEEP), tidal volume, and pneumonia. This investigation recruited mechanically ventilated patients, with and without pneumonia, aged 20 years old and above, from the respiratory intensive care unit of a medical center. Concentration distributions of EBPs from mechanically ventilated patients were analyzed with an optical particle analyzer. This study finds that EBP concentrations from mechanically ventilated patients during normal breathing were in the range 0.47–2,554.04 particles/breath (0.001–4.644 particles/mL). EBP concentrations did not differ significantly between the volume control and pressure control modes of the ventilation settings in the mechanically ventilated patients. The patient EBPs were sized below 5 µm, and 80% of them ranged from 0.3 to 1.0 µm. The EBPs concentrations in patients with high PEEP (> 5 cmH2O) clearly exceeded those in patients with low PEEP (≤ 5 cmH2O). Additionally, a significant negative association existed between pneumonia duration and EBPs concentration. However, tidal volume was not related to EBPs concentration.  相似文献   

4.
The application of positive end expiratory pressure (PEEP) in mechanically ventilated (MV) patients with acute respiratory distress syndrome (ARDS) decreases cardiac output (CO). Accurate measurement of CO is highly invasive and is not ideal for all MV critically ill patients. However, the link between the PEEP used in MV, and CO provides an opportunity to assess CO via MV therapy and other existing measurements, creating a CO measure without further invasiveness.  相似文献   

5.
The accuracy and clinical utility of preload indexes as bedside indicators of fluid responsiveness in patients after cardiac surgery is controversial. This study evaluates whether respiratory changes (Delta) in the preejection period (PEP; DeltaPEP) predict fluid responsiveness in mechanically ventilated patients. Sixteen postcoronary artery bypass surgery patients, deeply sedated under mechanical ventilation, were enrolled. PEP was defined as the time interval between the beginning of the Q wave on the electrocardiogram and the upstroke of the radial arterial pressure. DeltaPEP (%) was defined as the difference between expiratory and inspiratory PEP measured over one respiratory cycle. We also measured cardiac output, stroke volume index, right atrial pressure, pulmonary arterial occlusion pressure, respiratory change in pulse pressure, systolic pressure variation, and the Deltadown component of SPV. Data were measured without positive end-expiratory pressure (PEEP) and after application of a PEEP of 10 cmH2O (PEEP10). When PEEP10 induced a decrease of >15% in mean arterial pressure value, then measurements were re-performed before and after volume expansion. Volume loading was done in eight patients. Right atrial pressure and pulmonary arterial occlusion pressure before volume expansion did not correlate with the change in stroke volume index after the fluid challenge. Systolic pressure variation, DeltaPEP, Deltadown, and change in pulse pressure before volume expansion correlated with stroke volume index change after fluid challenge (r2 = 0.52, 0.57, 0.68, and 0.83, respectively). In deeply sedated, mechanically ventilated patients after cardiac surgery, DeltaPEP, a new method, can be used to predict fluid responsiveness and hemodynamic response to PEEP10.  相似文献   

6.
On-line monitoring of intrinsic PEEP in ventilator-dependent patients.   总被引:2,自引:0,他引:2  
Measurement of the intrinsic positive end-expiratory pressure (PEEP(i)) is important in planning the management of ventilated patients. Here, a new recursive least squares method for on-line monitoring of PEEP(i) is proposed for mechanically ventilated patients. The procedure is based on the first-order model of respiratory mechanics applied to experimental measurements obtained from eight ventilator-dependent patients ventilated with four different ventilatory modes. The model PEEP(i) (PEEP(i,mod)) was recursively constructed on an inspiration-by-inspiration basis. The results were compared with two well-established techniques to assess PEEP(i): end-expiratory occlusion to measure static PEEP(i) (PEEP(i, st)) and change in airway pressure preceding the onset of inspiratory airflow to measure dynamic PEEP(i) (PEEP(i,dyn)). PEEP(i, mod) was significantly correlated with both PEEP(i,dyn) (r = 0.77) and PEEP(i,st) (r = 0.90). PEEP(i,mod) (5.6 +/- 3.4 cmH(2)O) was systematically >PEEP(i,dyn) and PEEP(i,st) (2.7 +/- 1.9 and 8.1 +/- 5.5 cmH(2)O, respectively), in all the models without external PEEP. Focusing on the five patients with chronic obstructive pulmonary disease, PEEP(i,mod) was significantly correlated with PEEP(i,st) (r = 0.71), whereas PEEP(i,dyn) (r = 0.22) was not. When PEEP was set 5 cmH(2)O above PEEP(i,st), all the methods correctly estimated total PEEP, i.e., 11.8 +/- 5.3, 12.5 +/- 5.0, and 12.0 +/- 4.7 cmH(2)O for PEEP(i,mod), PEEP(i,st), and PEEP(i,dyn), respectively, and were highly correlated (0.97-0.99). We interpreted PEEP(i,mod) as the lower bound of PEEP(i,st) and concluded that our method is suitable for on-line monitoring of PEEP(i) in mechanically ventilated patients.  相似文献   

7.
Effects of airway pressure on bronchial blood flow   总被引:2,自引:0,他引:2  
We studied the effects of increased airway pressure caused by increasing levels of positive end-expiratory pressure (PEEP) on bronchial arterial pressure-flow relationships. In eight alpha-chloralose-anesthetized mechanically ventilated sheep (23-27 kg), the common bronchial artery, the bronchial branch of the bronchoesophageal artery, was cannulated and perfused with a pump. The control bronchial blood flow (avg 12 +/- 1 ml/min or 0.48 ml X min-1 X kg-1) was set to maintain mean bronchial arterial pressure equal to systemic blood pressure. Pressure-flow curves of the bronchial circulation were measured by making step changes in bronchial blood flow, and changes in these curves were analyzed with measurements of the pressure at zero flow and the slope of the linearized curve. The zero-flow pressure represents the effective downstream pressure, and the slope represents the resistance through the bronchial vasculature. At a constant bronchial arterial pressure of 100 mmHg, an 8 mmHg increase in mean airway pressure caused a 40% reduction in bronchial blood flow. Under constant flow conditions, increases in mean airway pressure with the application of PEEP caused substantial increases in bronchial arterial pressure, averaging 4.6 mmHg for every millimeters of mercury increase in mean airway pressure. However, bronchial arterial pressure at zero flow increased approximately one-for-one with increases in mean airway pressure. Thus the acute sensitivity of the bronchial artery to changes in mean airway pressure results primarily from changes in bronchovascular resistance and not downstream pressure.  相似文献   

8.
Lung mechanics and morphometry were assessed in two groups of nine normal open-chest rabbits mechanically ventilated (MV) for 3-4 h at zero end-expiratory pressure (ZEEP) with physiological tidal volumes (Vt; 11 ml/kg) and high (group A) or low (group B) inflation flow (44 and 6.1 ml x kg(-1) x s(-1), respectively). Relative to initial MV on positive end-expiratory pressure (PEEP; 2.3 cmH(2)O), MV on ZEEP increased quasi-static elastance and airway and viscoelastic resistance more in group A (+251, +393, and +225%, respectively) than in group B (+180, +247, and +183%, respectively), with no change in viscoelastic time constant. After restoration of PEEP, quasi-static elastance and viscoelastic resistance returned to control, whereas airway resistance, still relative to initial values, remained elevated more in group A (+86%) than in group B (+33%). In contrast, prolonged high-flow MV on PEEP had no effect on lung mechanics of seven open-chest rabbits (group C). Gas exchange on PEEP was equally preserved in all groups, and the lung wet-to-dry ratios were normal. Relative to group C, both groups A and B had an increased percentage of abnormal alveolar-bronchiolar attachments and number of polymorphonuclear leukocytes in alveolar septa, the latter being significantly larger in group A than in group B. Thus prolonged MV on ZEEP with cyclic opening-closing of peripheral airways causes alveolar-bronchiolar uncoupling and parenchymal inflammation with concurrent, persistent increase in airway resistance, which are worsened by high-inflation flow.  相似文献   

9.

Background

For mechanically ventilated patients with acute respiratory distress syndrome (ARDS), suboptimal PEEP levels can cause ventilator induced lung injury (VILI). In particular, high PEEP and high peak inspiratory pressures (PIP) can cause over distension of alveoli that is associated with VILI. However, PEEP must also be sufficient to maintain recruitment in ARDS lungs. A lung model that accurately and precisely predicts the outcome of an increase in PEEP may allow dangerous high PIP to be avoided, and reduce the incidence of VILI.

Methods and results

Sixteen pressure-flow data sets were collected from nine mechanically ventilated ARDs patients that underwent one or more recruitment manoeuvres. A nonlinear autoregressive (NARX) model was identified on one or more adjacent PEEP steps, and extrapolated to predict PIP at 2, 4, and 6 cmH2O PEEP horizons. The analysis considered whether the predicted and measured PIP exceeded a threshold of 40 cmH2O. A direct comparison of the method was made using the first order model of pulmonary mechanics (FOM(I)). Additionally, a further, more clinically appropriate method for the FOM was tested, in which the FOM was trained on a single PEEP prior to prediction (FOM(II)). The NARX model exhibited very high sensitivity (> 0.96) in all cases, and a high specificity (> 0.88). While both FOM methods had a high specificity (> 0.96), the sensitivity was much lower, with a mean of 0.68 for FOM(I), and 0.82 for FOM(II).

Conclusions

Clinically, false negatives are more harmful than false positives, as a high PIP may result in distension and VILI. Thus, the NARX model may be more effective than the FOM in allowing clinicians to reduce the risk of applying a PEEP that results in dangerously high airway pressures.
  相似文献   

10.
To assess the determinants of bronchopleural fistula (BPF) flow, we used a surgically created BPF to study 15 anesthetized intubated mechanically ventilated New Zealand White rabbits. Mean airway pressure and intrathoracic pressure were evaluated independently. Mean airway pressure was varied (8, 10, or 12 cmH2O) by independent manipulations of either peak inspiratory pressure, positive end-expiratory pressure, or inspiratory time. Intrathoracic pressure was varied from 0 to -40 cmH2O. BPF flow varied directly with mean airway pressure (P less than 0.001). However, at constant mean airway pressure, BPF flow was not influenced independently by changes in peak inspiratory pressure, positive end-expiratory pressure, or inspiratory time. Resistance of the BPF increased as intrathoracic pressure became more negative. Despite increased resistance, BPF flow also increased. BPF resistance was constant over the range of mean airway (P less than 0.01) pressures investigated. Our data document the influence of mean airway pressure and intrathoracic pressure on BPF flow and suggest that manipulations which reduce transpulmonary pressure will decrease BPF flow.  相似文献   

11.
Regional expiratory flow limitation studied with Technegas in asthma.   总被引:1,自引:0,他引:1  
Regional expiratory flow limitation (EFL) may occur during tidal breathing without being detected by measurements of flow at the mouth. We tested this hypothesis by using Technegas to reveal sites of EFL. A first study (study 1) was undertaken to determine whether deposition of Technegas during tidal breathing reveals the occurrence of regional EFL in induced bronchoconstriction. Time-activity curves of Technegas inhaled during 12 tidal breaths were measured in four asthmatic subjects at control conditions and after exposure to inhaled methacholine at a dose sufficient to abolish expiratory flow reserve near functional residual capacity. A second study (study 2) was conducted in seven asthmatic subjects at control and after three increasing doses of methacholine to compare the pattern of Technegas deposition in the lung with the occurrence of EFL. The latter was assessed at the mouth by comparing tidal with forced expiratory flow or with the flow generated on application of a negative pressure. Study 1 documented enhanced and spotty deposition of Technegas in the central lung regions with increasing radioactivity during tidal expiration. This is consistent with increased impaction of Technegas on the airway wall downstream from the flow-limiting segment. Study 2 showed that both methods based on analysis of flow at the mouth failed to detect EFL at the time spotty deposition of Technegas occurred. We conclude that regional EFL occurs asynchronously across the lung and that methods based on mouth flow measurements are insensitive to it.  相似文献   

12.
Lung mechanics and morphometry of 10 normal open-chest rabbits (group A), mechanically ventilated (MV) with physiological tidal volumes (8-12 ml/kg), at zero end-expiratory pressure (ZEEP), for 3-4 h, were compared with those of five rabbits (group B) after 3-4 h of MV with a positive end-expiratory pressure (PEEP) of 2.3 cmH(2)O. Relative to initial MV on PEEP, MV on ZEEP caused a progressive increase in quasi-static elastance (+36%) and airway (Rint; +71%) and viscoelastic resistance (+29%), with no change in the viscoelastic time constant. After restoration of PEEP, quasi-static elastance and viscoelastic resistance returned to control levels, whereas Rint remained elevated (+22%). On PEEP, MV had no effect on lung mechanics. Gas exchange on PEEP was equally preserved in groups A and B, and the lung wet-to-dry ratios were normal. Both groups had normal alveolar morphology, whereas only group A had injured respiratory and membranous bronchioles. In conclusion, prolonged MV on ZEEP induces histological evidence of peripheral airway injury with a concurrent increase in Rint, which persists after restoration of normal end-expiratory volumes. This is probably due to cyclic opening and closing of peripheral airways on ZEEP.  相似文献   

13.

Background

Baroreflex allows to reduce sudden rises or falls of arterial pressure through parallel RR interval fluctuations induced by autonomic nervous system. During spontaneous breathing, the application of positive end-expiratory pressure (PEEP) may affect the autonomic nervous system, as suggested by changes in baroreflex efficiency and RR variability. During mechanical ventilation, some patients have stable cardiorespiratory phase difference and high-frequency amplitude of RR variability (HF-RR amplitude) over time and others do not. Our first hypothesis was that a steady pattern could be associated with reduced baroreflex sensitivity and HF-RR amplitude, reflecting a blunted autonomic nervous function. Our second hypothesis was that PEEP, widely used in critical care patients, could affect their autonomic function, promoting both steady pattern and reduced baroreflex sensitivity.

Methods

We tested the effect of increasing PEEP from 5 to 10 cm H2O on the breathing variability of arterial pressure and RR intervals, and on the baroreflex. Invasive arterial pressure, ECG and ventilatory flow were recorded in 23 mechanically ventilated patients during 15 minutes for both PEEP levels. HF amplitude of RR and systolic blood pressure (SBP) time series and HF phase differences between RR, SBP and ventilatory signals were continuously computed by complex demodulation. Cross-spectral analysis was used to assess the coherence and gain functions between RR and SBP, yielding baroreflex-sensitivity indices.

Results

At PEEP 10, the 12 patients with a stable pattern had lower baroreflex gain and HF-RR amplitude of variability than the 11 other patients. Increasing PEEP was generally associated with a decreased baroreflex gain and a greater stability of HF-RR amplitude and cardiorespiratory phase difference. Four patients who exhibited a variable pattern at PEEP 5 became stable at PEEP 10. At PEEP 10, a stable pattern was associated with higher organ failure score and catecholamine dosage.

Conclusions

During mechanical ventilation, stable HF-RR amplitude and cardiorespiratory phase difference over time reflect a blunted autonomic nervous function which might worsen as PEEP increases.  相似文献   

14.
With the use of the technique of rapid airway occlusion during constant flow inflation, respiratory mechanics were studied in eight anesthetized paralyzed supine normal humans during zero (ZEEP) and positive end-expiratory pressure (PEEP) ventilation. PEEP increased the end-expiratory lung volume by 0.49 liter. The changes in transpulmonary and esophageal pressure after flow interruption were analyzed in terms of a seven-parameter "viscoelastic" model. This allowed assessment of static lung and chest wall elastance (Est,L and Est,W), partitioning of overall resistance into airway interrupter (Rint,L) and tissue resistances (delta RL and delta RW), and computation of lung and chest wall "viscoelastic constants." With increasing flow, Rint,L increased, whereas delta RL and delta RW decreased, as predicted by the model. Est,L, Est,W, and Rint,L decreased significantly with PEEP because of increased lung volume, whereas delta R and viscoelastic constants of lung and chest wall were independent of PEEP. The results indicate that PEEP caused a significant decrease in Rint,L, Est,L, and Est,W, whereas the dynamic tissue behavior, as reflected by delta RL and delta RW, did not change.  相似文献   

15.
This report describes the pulmonary vascular response of infant lamb lung to abrupt cessation of positive end-expiratory pressure (PEEP) during volume-regulated continuous positive-pressure breathing (CPPB). In an intact, endobronchially ventilated preparation, the increase in left lung blood flow (QL) after abrupt cessation of 11 Torr left lung PEEP was found to be gradual, although peak airway pressure (Pmax) fell promptly from 36 to 14 Torr; 49% of the increase in QL occurred greater than 10 s after cessation of PEEP. Recruitment of zone I vasculature that had been created by balloon occlusion of the left pulmonary artery was found to occur promptly after balloon deflation. Isolated neonatal lamb lungs, perfused at constant flow rate, showed similar persistent elevation of pulmonary vascular resistance after cessation of 15 Torr PEEP, although Pmax fell abruptly from 39 to 12 Torr. This hysteresis was eliminated by calcium channel blockade with verapamil, and the magnitude of the change in pulmonary arterial pressure after either application or cessation of PEEP was reduced (25 and 26%, respectively). These observations suggest that, during CPPB, lung stretch alters neonatal pulmonary vascular tone or, by causing calcium channel-dependent lung volume hysteresis, modulates pulmonary vascular resistance. This interaction exaggerates the effect of airway pressure changes on pulmonary vascular resistance during mechanical ventilation.  相似文献   

16.
OBJECTIVE--To assess oesophageal Doppler ultrasonography as a convenient means of optimising positive end expiratory pressure for maximal delivery of oxygen to tissues. DESIGN--Measurements of blood flow, arterial oxygen saturation, and cardiac output by thermodilution (when available) at baseline and at 20-30 minutes after each incremental increase (2.5-5.0 cm H2O) in positive and expiratory pressure to a maximum of 20.0 cm H2O. If the cardiac output fell by more than 15% measurements were repeated after stepwise decreases in positive end expiratory pressure. No other manoeuvre such as endotracheal suction or changing ventilator settings, drug or fluid dosage, or the patient''s position was performed for at least one hour before the start of the study or during it. SETTING--Intensive care unit. PARTICIPANTS--10 Patients being mechanically ventilated for acute respiratory failure who had stable haemodynamic and blood gas values and required a fractional inspired oxygen concentration of greater than or equal to 0.45. They were assessed on a total of 11 occasions. INTERVENTIONS--Incremental increases in positive end expiratory pressure followed when indicated by stepwise decreases. END POINT--The positive end expiratory pressure providing maximal delivery of oxygen to tissues. MEASUREMENTS and MAIN RESULTS--Arterial oxygen saturation increased with positive end expiratory pressure in all patients by an average of 6.1%. In nine of the 11 studies, however, cardiac output fell by 15% to 30% after the second increment. On the two other occasions cardiac output and oxygen delivery rose by up to 54%. Positive end expiratory pressure was decreased on seven occasions; there was considerable individual variation in the time taken for cardiac output to rise and arterial oxygen saturation to fall. In six patients good agreement was seen between the results from Doppler ultrasonography and thermodilution, the mean of the differences being -0.3% with narrow limits of agreement (-14.4% to 13.9%). CONCLUSIONS--Oesophageal Doppler ultrasonography is a rapid, safe, and reliable technique for optimising positive end expiratory pressure to obtain maximal delivery of oxygen to tissues. The results show the need to consider haemodynamic consequences when altering positive end expiratory pressure.  相似文献   

17.
Excessive mechanical ventilation results in changes in lung tissue mechanics. We hypothesized that changes in tissue properties might be related to changes in the extracellular matrix component proteoglycans (PGs). The effect of different ventilation regimens on lung tissue mechanics and PGs was examined in an in vivo rat model. Animals were anesthetized, tracheostomized, and ventilated at a tidal volume of 8 (VT(8)), 20, or 30 (VT(30)) ml/kg, positive end-expiratory pressure of 0 (PEEP(0)) or 1.5 (PEEP(1.5)) cmH(2)O, and frequency of 1.5 Hz for 2 h. The constant-phase model was used to derive airway resistance, tissue elastance, and tissue damping. After physiological measurements, one lung was frozen for immunohistochemistry and the other was reserved for PG extraction and Western blotting. After 2 h of mechanical ventilation, tissue elastance and damping were significantly increased in rats ventilated at VT(30)PEEP(0) compared with control rats (ventilated at VT(8)PEEP(1.5)). Versican, basement membrane heparan sulfate PG, and biglycan were all increased in rat lungs ventilated at VT(30)PEEP(0) compared with control rats. At VT(30)PEEP(0), heparan sulfate PG and versican staining became prominent in the alveolar wall and airspace; biglycan was mostly localized in the airway wall. These data demonstrate that alterations in lung tissue mechanics with excessive mechanical ventilation are accompanied by changes in all classes of extracellular matrix PG.  相似文献   

18.
Frequency-dependent characteristics of lung resistance (RL) and elastance (EL) are sensitive to different patterns of airway obstruction. We used an enhanced ventilator waveform (EVW) to measure inspiratory RL and EL spectra in ventilated patients during thoracic surgery. The EVW delivers an inspiratory flow waveform with enhanced spectral excitation from 0.156 to 8.1 Hz. Estimates of the coefficients in a trigonometric approximation of the EVW flow and transpulmonary pressure inspirations yielded inspiratory RL and EL spectra. We applied the EVW in a group with mild obstruction undergoing various thoracoscopic procedures (n = 6), and another group with severe chronic obstructive pulmonary disease undergoing lung volume reduction surgery (n = 8). Measurements were made at positive end-expiratory pressure (PEEP) of 0, 3, and 6 cmH(2)O. Inspiratory RL was similar in both groups despite marked differences in spirometry. The chronic obstructive pulmonary disease patients demonstrated a pronounced frequency-dependent increase in inspiratory EL consistent with severe heterogeneous peripheral airway obstruction. PEEP appears to have beneficial effects by reducing peripheral airway resistance. Lung volume reduction surgery resulted in increased inspiratory RL and EL at all frequencies and PEEPs, possibly due to loss of diseased lung tissue, pulmonary edema, increased mechanical heterogeneity, and/or an improvement in airway tethering.  相似文献   

19.
We examined the effect of high-frequency oscillatory ventilation (HFOV) on tracheal smooth muscle tension and upper airway resistance in anesthetized dogs. The animals were ventilated via a low tracheostomy by HFOV or conventional intermittent positive pressure ventilation (IPPV) with and without added positive end-expiratory pressure (PEEP). The transverse muscle tension of the trachea above the tracheostomy was measured and found to be lower during HFOV when compared with IPPV or IPPV with PEEP. When both vagi were cooled to 8 degrees C to interrupt afferent traffic from the lungs, there was no longer any difference between the modes of ventilation. In a second series of experiments, the airflow resistance of the upper airway above the tracheostomy was measured (Ruaw). During HFOV, Ruaw was significantly lower than during either IPPV or IPPV with PEEP. We conclude that HFOV induces a relaxation of tracheal smooth muscle and a reduction of upper airway resistance through a vagally mediated mechanism.  相似文献   

20.
The classic four-zone model of lung blood flow distribution has been questioned. We asked whether the effect of positive end-expiratory pressure (PEEP) is different between the prone and supine position for lung tissue in the same zonal condition. Anesthetized and mechanically ventilated prone (n = 6) and supine (n = 5) sheep were studied at 0, 10, and 20 cm H2O PEEP. Perfusion was measured with intravenous infusion of radiolabeled 15-microm microspheres. The right lung was dried at total lung capacity and diced into pieces (approximately 1.5 cm3), keeping track of the spatial location of each piece. Radioactivity per unit weight was determined and normalized to the mean value for each condition and animal. In the supine posture, perfusion to nondependent lung regions decreased with little relative perfusion in nondependent horizontal lung planes at 10 and 20 cm H2O PEEP. In the prone position, the effect of PEEP was markedly different with substantial perfusion remaining in nondependent lung regions and even increasing in these regions with 20 cm H2O PEEP. Vertical blood flow gradients in zone II lung were large in supine, but surprisingly absent in prone, animals. Isogravitational perfusion heterogeneity was smaller in prone than in supine animals at all PEEP levels. Redistribution of pulmonary perfusion by PEEP ventilation in supine was largely as predicted by the zonal model in marked contrast to the findings in prone. The differences between postures in blood flow distribution within zone II strongly indicate that factors in addition to pulmonary arterial, venous, and alveolar pressure play important roles in determining perfusion distribution in the in situ lung. We suggest that regional variation in lung volume through the effect on vascular resistance is one such factor and that chest wall conformation and thoracic contents determine regional lung volume.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号