《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2001,760(1):91-95
A high-performance liquid chromatographic method for the determination of ofloxacin in human plasma and urine was developed. The method involved deproteinisation of the sample with perchloric acid and analysis of the supernatant using a reversed-phase C18 column and fluorescence detection at an excitation wavelength of 290 nm and an emission wavelength of 460 nm. The assay was linear from 0.5 to 10.0 μg/ml. The relative standard deviation of intra- and inter-day assays was lower than 5%. The average recovery of ofloxacin from plasma was 93%. The method was evaluated in samples from healthy subjects whose drug levels were already measured by microbiological assay. 相似文献
2.
A.K. Hemanth Kumar Geetha Ramachandran 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2009,877(11-12):1205-1208
A high performance liquid chromatographic method for determination of moxifloxacin in human plasma was developed. The method involved deproteinisation of the sample with perchloric acid and analysis of the supernatant using a reversed-phase C18 column (150 mm) and fluorescence detection at an excitation wavelength of 290 nm and an emission wavelength of 460 nm. The assay was specific for moxifloxacin and linear from 0.125 to 10.0 μg/ml. The relative standard deviation of intra- and inter-day assays was lower than 10%. The average recovery of moxifloxacin from plasma was 101%. Due to its simplicity, the assay can be used for pharmacokinetic studies of moxifloxacin. 相似文献
3.
Ramachandran G Kumar AK Swaminathan S Venkatesan P Kumaraswami V Greenblatt DJ 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2006,835(1-2):131-135
A simple and rapid high performance liquid chromatographic method for determination of efavirenz in human plasma was developed. The method involved extraction of sample with ethyl acetate and analysis using a reversed-phase C(18) column (150 mm) with UV detection. The assay was linear from 0.0625 to 10.0 microg/ml. The method was specific for efavirenz estimation and the drug was stable in plasma up to one month at -20 degrees C. The average recovery of efavirenz from plasma was 101%. Due to its simplicity, the assay can be used for pharmacokinetic studies and therapeutic drug monitoring of efavirenz. 相似文献
4.
Mitsuhiro Ishida Kayoko Kobayashi Norio Awata Fumio Sakamoto 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1999,727(1-2)
A simple and reproducible method for the analysis of ampicillin in human serum was developed. Serum samples were extracted using solid-phase extraction disk cartridges containing a sorbent of styrene divinyl/benzene. Extracts were separated by reversed-phase C18 high-performance liquid chromatography with UV detection at 220 nm. The mobile phase consisted of acetonitrile–10 mM NaH2PO4 (6.5:93.5, v/v). Using this extraction procedure, recovery from serum was 98.4±5.6%. The quantitation limit was 0.19 μg/ml using 0.5 ml of serum. The calibration curves from 0.19 to 9.41 μg/ml were linear with correlation coefficients of 0.999. This method is suitable for therapeutic drug monitoring of ampicillin (ABPC) after oral administration of lenampicillin hydrochloride. 相似文献
5.
6.
Ramachandran G Hemanthkumar AK Kumaraswami V Swaminathan S 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2006,843(2):339-344
We describe a simple, fast, isocratic, reversed-phase high performance liquid chromatographic method for simultaneous determination of plasma zidovudine and nevirapine with UV detection at 260 nm. The method involves liquid-liquid extraction with ethyl acetate and using 3-isobutyl 1-methyl xanthine as internal standard. The system requires a C(18) column (150 mm x 4.6 mm I.D.) and a mobile phase composed of potassium dihydrogen phosphate (15 mM; pH 7.5) and acetonitrile in the ratio of 80:20 (v/v). The assay was linear from 0.025 to 10.0 microg/ml for zidovudine and 0.05 to 10.0 microg/ml for nevirapine. The intra- and inter-day variations were less than 10% for both the drugs. The method was specific and sensitive enough to allow quantification of zidovudine and nevirapine in concentrations observed clinically. The average recoveries of zidovudine and nevirapine from plasma were 95 and 94%, respectively. The method was applied to a pharmacokinetic study in HIV-infected patients who were receiving antiretroviral treatment with zidovudine and nevirapine containing regimens. The method spans the blood concentration range of clinical interest. Due to its simplicity, the assay can be used for pharmacokinetic studies and therapeutic drug monitoring in patients taking a combination treatment of zidovudine and nevirapine. 相似文献
7.
Madhu B. Garg Stephen P. Ackland 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2000,748(2):171
Several methods for quantification of docetaxel have been described mainly using HPLC. We have developed a new isocratic HPLC method that is as sensitive and simpler than previous methods, and applicable to use in clinical pharmacokinetic analysis. Plasma samples are spiked with paclitaxel as internal standard and extracted manually on activated cyanopropyl end-capped solid-phase extraction columns followed by isocratic reversed-phase HPLC and UV detection at 227 nm. Using this system, the retention times for docetaxel and paclitaxel are 8.5 min and 10.5 min, respectively, with good resolution and without any interference from endogenous plasma constituents or docetaxel metabolites at these retention times. The total run time needed is only 13 min. The lower limit of quantification is 5 ng/ml using 1 ml of plasma. The validated quantitation range of the method is 5–1000 ng/ml with RSDs≤10%, but plasma concentrations up to 5000 ng/ml can be accurately measured using smaller aliquots. This method is also suitable for the determination of docetaxel in urine samples under the same conditions. The method has been used to assess the pharmacokinetics of docetaxel during a phase I/II study of docetaxel in combination with epirubicin and cyclophosphamide in patients with advanced cancer. 相似文献
8.
A method is presented for the precolumn derivatization and subsequent high-pressure liquid chromatographic separation of 3-methylhistidine from urine and plasma. The solvent system is 10 mm sodium phosphate (pH 7.5) and acetonitrile. The elution can be performed isocratically and requires less than 10 min. Both fluorescent and ultraviolet detection may be utilized. This method is at least 103 times more sensitive than conventional ion-exchange chromatography using ninhydrin. 3-Methylhistidine determinations performed on plasma and urine samples from normal volunteers correlated well with published literature values. 相似文献
9.
Kumar AK Sudha V Srinivasan R Ramachandran G 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(30):3663-3667
A high performance liquid chromatographic method for determination of moxifloxacin in human saliva was developed. The method involved deproteinisation of the sample with perchloric acid and analysis of the supernatant using a reversed-phase C18 column (150 mm) and fluorescence detection at an excitation wavelength of 290 nm and an emission wavelength of 460 nm. The assay was specific for moxifloxacin and linear from 0.25 to 10.0 μg/ml. The relative standard deviation of intra- and inter-day assays was lower than 10%. The average recovery of moxifloxacin from saliva was 101%. Due to its simplicity, the assay can be used for pharmacokinetic studies of moxifloxacin. 相似文献
10.
Diane T. Holland Kristin A. Godfredsen Theodore Page James D. Connor 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1998,707(1-2)
A simple reversed-phase high-performance liquid chromatography (HPLC) method for the simultaneous determination of caffeine and paraxanthine in human serum is described. Serum proteins are precipitated with perchloric acid and the resulting supernatant neutralized for direct injection onto an HPLC column. The method uses a phosphate–methanol mobile phase (85:15, v/v) at pH 4.9 with a flow-rate of 1.75 ml/min and quantitation is by UV absorbance at 274 nm. Elution times are approximately 18 min for caffeine and 8 min for paraxanthine. Theobromine and theophylline have elution times of 5.4 and 9.4 min and do not interfere in the assay. The intra-assay and between-assay means for precision and accuracy for both drugs are: 4.5% C.V. and 3.3% deviation. The sensitivity of the method is 50 ng/ml for each drug. 相似文献
11.
Bauer S Mwinyi J Stoeckle A Gerloff T Roots I 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2005,818(2):257-262
A high performance liquid chromatography (HPLC) method for the estimation of pravastatin in human plasma and urine samples has been developed. The preparation of the samples was performed by automated solid phase extraction using clonazepam as internal standard. The compounds were separated by isocratic reversed-phase HPLC (C(18)) and detected at 239 nm. The method was linear up to concentrations of 200 ng/ml in plasma and 2000 ng/ml in urine. The intra-assay variability for pravastatin in plasma ranged from 0.9% to 3.5% and from 2.5% to 5.3% in urine. The inter-assay variability ranged from 9.1% to 10.2% in plasma and from 3.9% to 7.5% in urine. The validated limits of quantification were 1.9 ng/ml for plasma and 125 ng/ml for urine estimation. These method characteristics allowed the determination of the pharmacokinetic parameters of pravastatin after administration of therapeutic doses. 相似文献
12.
A new gas-chromatographic mass-spectrometric method for the rapid determination of 11-dehydro-thromboxane B2 in urine, the major metabolite of systemic thromboxane formation, has been developed. Excellent sample clean-up was obtained in a single step by adsorption of 11-dehydro-TXB2 on phenylboronate cartridges, vigorous polar and organic washing and elution with an acidic methanol mixture. Then the pentafluorobenzylester trimethylsilylether derivative of 11-dehydro-TXB2 was formed and quantified in isotope dilution technique by negative chemical ionisation gas-chromatography tandem mass-spectrometry. The daughter fragments m/z 243/247 of the parent ion m/z 511/515 were monitored. Recovery was linear and quantitative over a wide range, accuracy was 95 + 7% and precision was 11% down to the very low pg range in biologic samples. Independent validation of this very fast extraction method with a reference method applying extensive sample purification with consecutive reversed and straight phase extraction, precolumn derivatisation, reversed phase high pressure liquid chromatography and tandem gas-chromatography mass-spectrometry gave excellent agreement of values. Values for 11-dehydro-TXB2 excretion in 8 healthy controls were 501 + 298 (range 231 to 1141) ng/g creatinin. Excretion was suppressed by aspirin, moderately elevated in heavy smokers (range 680 to 1540) and increased in patients with venous thrombosis or pulmonary embolism (2370 to 13350 ng/g creatinin). This rapid extraction method is useful for the highly specific and sensitive determination of 11-dehydro-TXB2 in large sample numbers. 相似文献
13.
Roger L. Nation Geoffrey W. Peng Win L. Chiou 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1978,146(1):121-131
A rapid high-pressure liquid chromatographic (HPLC) assay is described for the quantitative analysis of tolbutamide and its major metabolite, carboxy tolbutamide, in plasma. An aliquot (25–100 μl) of plasma was prepared for chromatography by deproteinization as follows. One volume of plasma and 2.5 volumes of acetonitrile were vortex mixed for a few seconds and then centrifuged for approx. 1 min. A 50-μl sample of the clear supernatant was injected into the chromatograph. A μBondapak C12 reversed-phase column was used with a mobile phase of acetonitrile-0.05% phosphoric acid (45:55) at a flow-rate of 1.5 ml/min. The column effluent was monitored by a variable-wavelength UV detector set at 200 nm. Tolbutamide and its metabolite had retention times of 5.75 and 3.25 min, respectively. The procedure yields reproducible results with sensitivity adequate for routine clinical monitoring of plasma levels or for single-dose pharmacokinetic studies. A number of commonly used drugs do not interfere with the method. A single plasma sample can be analyzed in approx. 9 or 10 min. 相似文献
14.
Yau WP Vathsala A Lou HX Chan E 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2004,805(1):101-112
A simple and reproducible reversed-phase ion-pair high-performance liquid chromatographic (HPLC) method using isocratic elution with UV absorbance detection is presented for the simultaneous quantitation of mycophenolic acid (MPA) and MPA-glucuronide (MPAG) in human plasma and urine. The sample preparation procedures involved simple protein precipitation for plasma and 10-fold dilution for urine. Each analytical run was completed within 15min, with MPAG and MPA being eluted at 3.8 and 11.4min, respectively. The optimized method showed good performance in terms of specificity, linearity, detection and quantitation limits, precision and accuracy. This assay was demonstrated to be applicable for clinical pharmacokinetic studies. 相似文献
15.
Xiao-jun Deng De-hua Guo Shan-zhen Zhao Li Han Yong-gang Sheng Xiong-hai Yi Yao Zhou Tao Peng 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(28):2839-2844
Utilizing a solid phase extraction column (MCT) containing mixed hydrophilic functional gel and cation exchange sorbent, a sensitive and rapid HPLC–MS/MS method for simultaneously determining the residues of melamine (MEL) and cyanuric acid (CYA) in human foodstuffs was developed. MEL and CYA in egg, pork, liver, kidney and pork, shrimp, sausage casing, honey, soybean milk, soybean powder and dairy product were extracted using acetonitrile/water, defatted with hexane and isolated using MCT solid phase extraction column. The residues were separated upon a hydrophilic interaction liquid chromatography (HILIC) column and analyzed by electrospray ionization under negative–positive switched mode on a triplequadrupole mass spectrometry. The selected reaction monitoring was performed on [M+H]+ of m/z 127.9 to provide the transition of 127 > 85 and 127 > 68 (MEL) while the [M−H]− of m/z 127.1 was selected as the precursor ion for CYA resulting in product ions m/z 85 and 42. Isotope labeled internal standard (15N3-MEL and 13C3-CYA) and matrix-matched calibration were both used to observe the recovery to be 70.0–129.6% and 70.0–128.9% with RSD of 1.4–23.3% and 1.5–21.7% for MEL and CYA, respectively (n = 6). All the LODs and LOQs of MEL and CYA were less than 39.4 and 99.1 μg kg−1, respectively, in 18 matrices, which were sensitive enough for quantitative analysis. This method has been proven effective in simultaneous determination of melamine and cyanuric acid when inspecting unknown and positive samples. 相似文献
16.
Vanessa L. Herring Julie A. Johnson 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2000,741(2)
A method is described in which low nanomolar concentrations of terbutaline in plasma can be quantitated by use of a standard isocratic high-performance liquid chromatography system with electrochemical detection. Samples were prepared for injection by solid-phase extraction and preserved from degradation by addition of glutathione. Terbutaline and internal standard metaproterenol were resolved from plasma constituents on a single C18 column by ion-pairing chromatography. The method is precise and accurate for measurement of freebase concentrations as low as 4.4 nmol/l (1 ng/ml). 相似文献
17.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1997,692(1):241-244
A micro method for determination of indomethacin in plasma was developed. Following deproteinization of plasma with acetonitrile containing internal standard (mefenamic acid), the separation of indomethacin and internal standard was achieved by high-performance liquid chromatography using a 7 μm LiChrosorb-RP18 column (250×4 mm I.D.) at 50°C. The mobile phase was 6 mM phosphoric acid–acetonitrile (50:50). The flow-rate was kept at 2.0 ml/min and the column effluent was monitored at 205 nm. The coefficients of variation of the method estimated at 0.2 and 1.0 μg/ml were 4.2 and 2.3%, and the detection limit of the drug was about 0.05 μg/ml (S/N=5). The method requires minimum pretreatment of the plasma with a small sample volume (25 μl), and is very suitable for therapeutic drug monitoring of indomethacin in premature infants with symptomatic patent ductus arteriosus. 相似文献
18.
Lin MC Kou HS Chen CC Wu SM Wu HL 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2004,810(1):169-172
A simple and sensitive liquid chromatographic method is described for the analysis of valproic acid in human plasma. The method is based on the derivatization of valproic acid extracted from acidified plasma with 2-(2-naphthoxy)ethyl 2-(piperidino)ethanesulfonate. The resulting derivative is highly responsive to a fluorimetric detector (excitation at 230 nm and emission at 350 nm), giving a low detection limit of 0.6 microM (S/N = 3, 10 microl injected). The relative standard deviations of the method for intra- and inter-day analyses (n = 5) are below 3.3 and 4.1%, respectively. Toluene was used for the extraction of valproic acid from plasma and the toluene extract obtained was subjected to subsequent derivatization without solvent replacement. The simple method was applied to the analysis of valproic acid in plasma of dosed patients using only small amount of sample (10-50 microl plasma). 相似文献
19.
Rezk NL Crutchley RD Kashuba AD 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2005,822(1-2):201-208
An accurate, sensitive and simple reverse-phase (RP) high-performance liquid chromatography (HPLC) assay for the simultaneous quantitative determination of emtricitabine and tenofovir in human blood plasma is described. Using 200 microL of plasma and BOND ELUT-C18 Varian columns, the solid phase extraction (SPE) method results in a clean baseline and high extraction efficiencies (100% for emtricitabine and 98.6% for tenofovir). An Atlantistrade mark dC-18 analytical column is used along with an 18 min linear gradient elution of phosphate buffer (pH 5.7) and methanol to provide sharp peaks for emtricitabine at 280 nm, tenofovir at 259 nm, and the internal standard 2',3'didoxyuridine (DDU) at 262 nm. The method was validated over the range of 10-10,000 ng/mL for both analytes, and is accurate (average accuracies of three different concentrations ranged from 98 to 105% for emtricitabine and 97 to 103% for tenofovir) and precise (within- and between-day precision ranged from 1.7 to 3.7% and 3.7 to 5.2%, respectively). This method is suitable for use in clinical pharmacokinetic studies and is nimble enough for therapeutic drug monitoring. 相似文献
20.
R. Lorenz P. Helmer W. Uedelhoven B. Zimmer P.C. Weber 《Prostaglandins & other lipid mediators》1989,38(2)
A new gas-chromatographic mass-spectrometric method for the rapid determination of 11-dehydro-thromboxane B2 in urine, the major metabolite of systemic thromboxane formation, has been developed. Excellent sample clean-up was obtained in a single step by adsorption of 11-dehydro-TXB2 on phenylboronate cartridges, vigorous polar and organic washing and elution with an acidic methanol mixture. Then the pentafluorobenzylester trimethylsilylether derivative of 11-dehydro-TXB2 was formed and quantified in isotope dilution technique by negative chemical ionisation gas-chromatography tandem mass-spectrometry. The daughter fragments m/z 243/247 of the parent ion m/z 511/515 were monitored. Recovery was linear and quantitative over a wide range, accuracy was 95+7% and precision was 11% down to the very low pg range in biologica samples. Independent validation of this very fast extraction method with a reference method applying extensive sample purification with consecutive reversed and straight phase extraction, precolumn derivatisation, reversed phase high pressure liquid chromatography and tandem gas-chromatography mass-spectrometry gave excellent agreement of values. Values of 11-dehydro-TXB2 excretion in 8 healthy controls were 501+298 (range 231 to 1141) ng/g creatinin. Excretion was suppressed by aspirin, moderately elevated in heavy smokers (range 680 to 1540) and increased in patients with venous thrombosis or pulmonary embolism (2370 to 13350 ng/g creatinin). This rapid extraction method is useful for the highly specific and sensitive determination of 11-dehydro-TXB2 in large sample numbers. 相似文献