首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
目的:探讨数字化导航技术在人工全膝关节置换术中应用的可行性及初步临床应用。方法:对我院2013年6月至2014年6月行单侧全膝关节置换术的80例患者,按照抽签法随机分为数字化导航组40例及传统手术组40例,导航组术前设计个性化定制导航模板,术中应用导航模板截骨,传统组应用厂家器械截骨。分别测量两组患者手术前后的髋-膝-踝角、冠状面股骨和胫骨截骨面与机械轴夹角、矢状面股骨和胫骨截骨面与外旋和后倾夹角,记录每一例患者手术时间及术中出血量并进行对比。结果:数字化导航组患者的手术时间及术中出血量均少于传统手术组,差异具有统计学意义(P0.05)。与传统手术组比较,数字化导航组术后冠状面FFC角及FTC角平均偏差角度较小,差异具有统计学意义(P0.05)。与传统手术组比较,数字化导航组术后矢状面LFC角及LTC角平均偏差角度较小,差异具有统计学意义(P0.05)。结论:数字化导航技术在人工膝关节置换术中具有快速、个性化及精确性高等优点,值得临床推广应用。  相似文献   

2.

Background

Thirty thousand knee replacements are performed annually in the UK. There is uncertainty as to the best surgical approach to the knee joint for knee arthroplasty. We planned a randomised controlled trial to compare a standard medial parapatellar arthrotomy with sub-vastus arthrotomy for patients undergoing primary total knee arthroplasty in terms of short and long term knee function.

Methods

Patients undergoing primary total knee arthroplasty at the local NHS Trust are to be recruited into the study. Patients are to be randomised into either the subvastus or medial parapatellar approache to knee arthroplasty. The primary outcome measures will be the American Knee Society and WOMAC Scores. The secondary outcome measures will be patient based measures of EuroQol and SF-36. All outcomes will be measured pre-operatively, 1, 6, 12 and 52 weeks post-operatively. We will also review pain intensity using a pain and analgesia diary. Ease of surgical exposure and complications will also be analysed.

Discussion

Evidence is lacking concerning the best surgical approach to the knee joint for patients undergoing primary total knee replacement. This pragmatic randomised trial tests the hypothesis that the sub-vastus approach is significantly superior to the standard medial parapatellar approach in terms of short and long term knee function.  相似文献   

3.
BACKGROUND: The management of soft tissue balance during surgery is essential for the success of total knee arthroplasty (TKA) but remains difficult, leaving it much to the surgeon's feel. Previous assessments for soft tissue balance have been performed under unphysiological joint conditions, with patellar eversion and without the prosthesis only at extension and 90 deg of flexion. We therefore developed a new tensor for TKA procedures, enabling soft tissue balance assessment throughout the range of motion while reproducing postoperative joint alignment with the patellofemoral (PF) joint reduced and the tibiofemoral joint aligned. Our purpose in the present study was to clarify joint gap kinematics using the tensor with the CT-free computer assisted navigation system. METHOD OF APPROACH: Joint gap kinematics, defined as joint gap change during knee motion, was evaluated during 30 consecutive, primary posterior-stabilized (PS) TKA with the navigation system in 30 osteoarthritic patients. Measurements were performed using a newly developed tensor, which enabled the measurement of the joint gap throughout the range of motion, including the joint conditions relevant after TKA with PF joint reduced and trial femoral component in place. Joint gap was assessed by the tensor at full extension, 5 deg, 10 deg, 15 deg, 30 deg, 45 deg, 60 deg, 90 deg, and 135 deg of flexion with the patella both everted and reduced. The navigation system was used to obtain the accuracy of implantations and to measure an accurate flexion angle of the knee during the intraoperative joint gap measurement. RESULTS: Results showed that the joint gap varied depending on the knee flexion angle. Joint gap showed an accelerated decrease during full knee extension. With the PF joint everted, the joint gap increased throughout knee flexion. In contrast, the joint gap with the PF joint reduced increased with knee flexion but decreased after 60 deg of flexion. CONCLUSIONS: We clarified the characteristics of joint gap kinematics in PS TKA under physiological and reproducible joint conditions. Our findings can provide useful information for prosthetic design and selection and allow evaluation of surgical technique throughout the range of knee motion that may lead to consistent clinical outcomes after TKA.  相似文献   

4.
Component mal-alignment in total knee arthroplasty has been associated with increased revision rates and poor clinical outcomes. A significant source of variability in traditional, jig-based total knee arthroplasty is the performance of the surgeon. The purpose of this study was to determine the most sensitive steps in the femoral and tibia arthroplasty procedures. A computational model of the total knee arthroplasty procedure was created, and Monte Carlo simulations were performed that included surgeon variability in each step of the procedure. The proportion of well-aligned components from the model agrees with clinical literature in most planes. When components must be aligned within ±3° in all planes, component alignment was most sensitive to the accuracy of identifying the lateral epicondyle for the femoral component, and to the precision of the transverse plane alignment of the extramedullary guide for the tibial component. This model can be used as a tool for evaluating different procedural approaches or sources of variability to improve the quality of the total knee arthroplasty procedure.  相似文献   

5.
Few in-vitro studies have investigated changes in kinematics caused by total knee replacement (TKR) implantation. The advent of surgical navigation systems allows implant position to be measured accurately and the effects of alteration of TKR position and alignment investigated. A test rig and protocol were developed to compare the kinematics of TKR-implanted knees for different femoral component positions. The TKR was implanted and the component positions documented using a navigation system. The quadriceps was tensed and the knees were flexed and extended manually. Torques and drawer forces were applied to the tibia during knee flexion–extension, while recording the kinematics with the navigation system. The implant was removed and replaced on an intramedullary fixation that allowed proximal–distal, and internal–external rotation of the femoral component without conducting a repeated arthrotomy on the knee. The implant was repositioned using the navigation system to reproduce the previously achieved normally navigated position and the kinematics were recorded again. The recorded kinematics of the knee were not significantly different between both normal implantation and intramedullary remounting for tibial internal–external rotation, varus–valgus angulation, or posterior drawer, at any angle of knee flexion examined. Anterior drawer was increased approximately 2.5 mm across the range 20–35° knee flexion (p<0.05), but was otherwise not significantly different. This method of navigating implant components and of moving them within the closed knee (thus avoiding artefactual effects of repeated soft tissue manipulations) can now be used to quantify the effect on kinematics of alteration of the position of the femoral component.  相似文献   

6.
In order to determine whether there is a genetic component to hip or knee joint failure due to idiopathic osteoarthritis (OA), we invited patients (probands) undergoing hip or knee arthroplasty for management of idiopathic OA to provide detailed family histories regarding the prevalence of idiopathic OA requiring joint replacement in their siblings. We also invited their spouses to provide detailed family histories about their siblings to serve as a control group. In the probands, we confirmed the diagnosis of idiopathic OA using American College of Rheumatology criteria. The cohorts included the siblings of 635 probands undergoing total hip replacement, the siblings of 486 probands undergoing total knee replacement, and the siblings of 787 spouses. We compared the prevalence of arthroplasty for idiopathic OA among the siblings of the probands with that among the siblings of the spouses, and we used logistic regression to identify independent risk factors for hip and knee arthroplasty in the siblings. Familial aggregation for hip arthroplasty, but not for knee arthroplasty, was observed after controlling for age and sex, suggesting a genetic contribution to end-stage hip OA but not to end-stage knee OA. We conclude that attempts to identify genes that predispose to idiopathic OA resulting in joint failure are more likely to be successful in patients with hip OA than in those with knee OA.  相似文献   

7.
In order to determine whether there is a genetic component to hip or knee joint failure due to idiopathic osteoarthritis (OA), we invited patients (probands) undergoing hip or knee arthroplasty for management of idiopathic OA to provide detailed family histories regarding the prevalence of idiopathic OA requiring joint replacement in their siblings. We also invited their spouses to provide detailed family histories about their siblings to serve as a control group. In the probands, we confirmed the diagnosis of idiopathic OA using American College of Rheumatology criteria. The cohorts included the siblings of 635 probands undergoing total hip replacement, the siblings of 486 probands undergoing total knee replacement, and the siblings of 787 spouses. We compared the prevalence of arthroplasty for idiopathic OA among the siblings of the probands with that among the siblings of the spouses, and we used logistic regression to identify independent risk factors for hip and knee arthroplasty in the siblings. Familial aggregation for hip arthroplasty, but not for knee arthroplasty, was observed after controlling for age and sex, suggesting a genetic contribution to end-stage hip OA but not to end-stage knee OA. We conclude that attempts to identify genes that predispose to idiopathic OA resulting in joint failure are more likely to be successful in patients with hip OA than in those with knee OA.  相似文献   

8.
Ligament balancing in total knee arthroplasty may have an important influence on joint stability and prosthesis lifetime. In order to provide quantitative information and assistance during ligament balancing, a device that intraoperatively measures knee joint forces and moments was developed. Its performance and surgical advantages were evaluated on six cadaver specimens mounted on a knee joint loading apparatus allowing unconstrained knee motion as well as compression and varus-valgus loading. Four different experiments were performed on each specimen. (1) Knee joints were axially loaded. Comparison between applied and measured compressive forces demonstrated the accuracy and reliability of in situ measurements (1.8N). (2) Assessment of knee stability based on condyle contact forces or varus-valgus moments were compared to the current surgical method (difference of varus-valgus loads causing condyle lift-off). The force-based approach was equivalent to the surgical method while the moment-based, which is considered optimal, showed a tendency of lateral imbalance. (3) To estimate the importance of keeping the patella in its anatomical position during imbalance assessment, the effect of patellar eversion on the mediolateral distribution of tibiofemoral contact forces was measured. One fourth of the contact force induced by the patellar load was shifted to the lateral compartment. (4) The effect of minor and major medial collateral ligament releases was biomechanically quantified. On average, the medial contact force was reduced by 20% and 46%, respectively. Large variation among specimens reflected the difficulty of ligament release and the need for intraoperative force monitoring. This series of experiments thus demonstrated the device's potential to improve ligament balancing and survivorship of total knee arthroplasty.  相似文献   

9.
全膝关节置换术治疗骨关节炎   总被引:1,自引:0,他引:1  
目的 探讨人工全膝关节置换术治疗骨关节病的临床疗效。方法 对31例人工全膝关节置换术进行临床分析和总结,并应用HSS膝关节评分系统进行分析。结果 手术优良率为93.6%,患者术后在疼痛、功能及关节活动度等方面都有明显改善。结论 全膝关节置换术是治疗骨关节病的有效方法。  相似文献   

10.
抗凝药物有助于预防全髋关节置换术和全膝关节置换术后深静脉血栓形成,临床上最常使用的传统抗凝药物如低分子肝素、华法林等可以起到很好的预防效果。目前有一类新的口服抗凝药物已经用于临床,为关节置换术后患者带来了一种更方便、安全和有效预防血栓的治疗选择。本篇综述主要针对传统抗凝药物低分子肝素及维生素K拮抗剂,直接凝血酶抑制剂达比加群,以及选择性Xa因子抑制剂利伐沙班和阿哌沙班,对迄今为止传统抗凝药物在全髋关节置换术和全膝关节置换术患者中的临床使用经验、优缺点、以及新型口服抗凝药物最新临床用药进展进行综述,为关节置换术后患者预防深静脉血栓提供用药参考。  相似文献   

11.
OBJECTIVE--To determine the prevalence of knee problems in people aged 55 years and over and identify those who should be considered for knee arthroplasty. DESIGN--Postal survey; questionnaires were sent to a multistage stratified probability sample of residents of North Yorkshire Health Authority aged 55 and over. SETTING--A health district with a population of 210,000 aged 55 and over. RESULTS--An initial four page postal questionnaire produced an 86% response rate among 18,827 eligible patients. A subsequent detailed questionnaire sent to 1277 patients with knee problems (with a response rate of 78%) then determined the prevalence of severe pain and severe disability. Pain and disability consistent with the need to consider arthroplasty was found in 20.4/1000 (95% confidence interval 18.0 to 23.1); of these, 4.1 (2.7 to 5.8)/1000 had extreme disability. Age and sex specific rates in men who might benefit from arthroplasty were, in those aged 55-64, 12.9 (8.4 to 19.0)/1000; aged 65-74, 12.1 (7.4 to 18.4)/1000; aged 75 and over, 20.3 (12.9 to 30.5)/1000. In women aged 55-64 the rates were 12.9 (8.6 to 18.7)/1000; aged 65-74, 19.6 (13.9 to 26.7)/1000; aged 75 years and over, 42.6 (34.3 to 52.4)/1000. CONCLUSIONS--Total knee replacement has until recently been considered unreliable and often seen as a last resort for many with severe knee problems. Advances in prosthesis design and surgical and anaesthetic techniques have transformed this procedure into a reliable option with a potential for reducing disability and dependency in a large number of people in the community. Understandably, the prevalence pool of those who may benefit is large; health authorities and, increasingly, general practitioners should consider purchasing more total knee replacement surgery to offer real choice to those in need.  相似文献   

12.
The aim of this study was to evaluate the impact of total hip or knee arthroplasty upon quality of life in elderly patients. The study was carried out at the Clinic for Orthopaedic Surgery Lovran on 74 total hip arthroplasty and 70 total knee arthroplasty patients. All patients had completed the Medical Outcomes Study 36-Item Short Form in the week having preceded their surgery and then again postoperatively, 2 years after. The data obtained were statistically processed at the level of physical function, role limitations due to physical problems, role limitations due to emotional problems, social function, mental health, energy or vitality, pain and general health perception, and change in health. The primary total hip arthroplasty patients showed significant improvement at all levels measured. Similarly, the primary total knee arthroplasty patients expressed significant improvement according to all the parameters but the mental health assessment. Comparison of outcomes between the two assessment groups of patients resulted in slightly superior quality of life outcomes in total hip arthroplasty patients. It can be concluded that total hip or knee arthroplasty significantly enhances the health related quality of life in elderly patients.  相似文献   

13.

Background

The underuse of total joint arthroplasty in appropriate candidates is more than 3 times greater among women than among men. When surveyed, physicians report that the patient''s sex has no effect on their decision-making; however, what occurs in clinical practice may be different. The purpose of our study was to determine whether patients'' sex affects physicians'' decisions to refer a patient for, or to perform, total knee arthroplasty.

Methods

Seventy-one physicians (38 family physicians and 33 orthopedic surgeons) in Ontario performed blinded assessments of 2 standardized patients (1 man and 1 woman) with moderate knee osteoarthritis who differed only by sex. The standardized patients recorded the physicians'' final recommendations about total knee arthroplasty. Four surgeons did not consent to the inclusion of their data. After detecting an overall main effect, we tested for an interaction with physician type (family physician v. orthopedic surgeon). We used a binary logistic regression analysis with a generalized estimating equation approach to assess the effect of patients'' sex on physicians'' recommendations for total knee arthroplasty.

Results

In total, 42% of physicians recommended total knee arthroplasty to the male but not the female standardized patient, and 8% of physicians recommended total knee arthroplasty to the female but not the male standardized patient (odds ratio [OR] 4.2, 95% confidence interval [CI] 2.4–7.3, p < 0.001; risk ratio [RR] 2.1, 95% CI 1.5–2.8, p < 0.001). The odds of an orthopedic surgeon recommending total knee arthroplasty to a male patient was 22 times (95% CI 6.4–76.0, p < 0.001) that for a female patient. The odds of a family physician recommending total knee arthroplasty to a male patient was 2 times (95% CI 1.04–4.71, p = 0.04) that for a female patient.

Interpretation

Physicians were more likely to recommend total knee arthroplasty to a male patient than to a female patient, suggesting that gender bias may contribute to the sex-based disparity in the rates of use of total knee arthroplasty.Disparity in the use of medical or surgical interventions based on patient characteristics, such as sex, ethnic background or socioeconomic status, is an important health care issue.1 Women are less likely than men to receive lipid-lowering medication after a myocardial infarction,2 receive kidney dialysis,3 be admitted to an intensive care unit,4 or undergo cardiac catheterization,5 renal transplantation6 or total joint arthroplasty.7 Although women''s preferences for surgery or the information needed to make an informed decision may differ from men and explain sex-based differences in care,8,9 subtle or overt gender bias may inappropriately influence physicians'' clinical decision-making.2,5,7 A more pronounced gender bias might be expected when the clinical decision involves an elective surgical procedure such as total joint arthroplasty.Total hip and knee arthroplasty is the definitive treatment for relieving pain and restoring function in people with moderate to severe osteoarthritis for whom medical therapy has failed.10 Although age-adjusted rates of total joint arthroplasty are higher among women than among men,11 based on a population-based epidemiologic survey, underuse of arthroplasty is 3 times greater in women.7 In prior opinion surveys, more than 93% of referring physicians and orthopedic surgeons have reported that patients'' sex has no effect on their decision to refer a patient for, or perform, total knee arthroplasty.12,13 However, there may be a difference between what is reported in a survey and what occurs in clinical practice. The purpose of our study was to determine whether physicians would provide the same recommendation about total knee arthroplasty to a male and a female standardized patient presenting to their offices with identical clinical scenarios that differed only by sex.  相似文献   

14.
人工单髁关节置换在治疗单间室骨关节炎已经有超过30年的历史,尽管早期的报告不尽如人意,但目前是可靠并安全的治疗关节炎的方法。单髁置换术的成功关键在于合适的患者的选择、细致的手术技术和避免对畸形的过度矫正。本文对人工单髁置换手术的发展历史作了简单回顾,然后分别对膝关节内、外侧单髁置换术患者的选择、手术要点、临床疗效、失败原因作一综述,并对其未来研究进行展望。  相似文献   

15.
J. Chaoui  E. Stindel  C. Hamitouche 《IRBM》2012,33(5-6):277-280
This study concerns the general problem of the treatment of shoulder degenerative or traumatic lesions, based on total or partial joint replacement (shoulder arthroplasty). With baby boomers, increasingly complaining of shoulder pain, the number of shoulder arthroplasties increased by 15% each year. This surgical procedure is very difficult and limited to the expert centers. The two main challenges for this surgery are the minimal surgical incision and the limited access to the operated structures. Moreover, the success of such procedure is related to optimal prosthesis positioning. So far, the existing optimization and guiding systems are now very limited, which is no longer acceptable. Some mechanical systems may enhance the prosthetic components orientation but do not ensure an implant positioning taking into account the bone stock because it is not visible during the surgery. Only the preoperative evaluation on CT images could enhance the final gesture. To meet strong demand and meet the limitations of current solutions, we propose innovative approaches to build a navigation system easy to use and fully automatic for shoulder surgery.  相似文献   

16.
Using a three-dimensional (3D) modality to image patients' knees before and after total knee arthroplasty (TKA) allows researchers and clinicians to evaluate causes of pain after TKA, differences in implant design, and changes in the articular geometry as a result of surgery. Computed tomography (CT) has not been fully utilized to date for evaluating the knee after TKA due to metal artifacts obscuring part of the image. We describe an accurate, validated protocol, which has been implemented in vivo, that improves visibility of the patellofemoral joint, matches implant models automatically in 3D, segments preoperative bone semi-automatically, detects and sets coordinate systems automatically, determines the six degrees of freedom of knee pose and geometry, and allows for multiple other measurements that are clinically relevant. Subjects are imaged at 0° and 30° knee flexion, while pushing on a custom-made knee rig to provide partial loadbearing. With some modifications, the protocol can be adopted by any group with access to a CT scanner and image analysis software, allowing for the investigation of numerous clinical and biomechanical questions.  相似文献   

17.
The method of retransfusion of drainage blood as known from the literature was investigated in a prospectiv study regarding effectivness and rate of side effects. 200 patients who underwent total hip and knee arthroplasty were investigated concerning hemoglobin, hematocrit, amount and quality of the retransfused drainage blood, the amount of autologous and homologous transfusions as well as complications and costs. 100 of these patients were selected as the control group. The amount of the retransfused drainage blood after hip arthroplasty amounted an average of 387 +/- 194 ml and after knee arthroplasty 595 +/- 250 ml. The retransfused blood had an average hemoglobin of 5,2 +/- 0,9mmol/l with a hematocrit of 0,24 0,05. No complications directly associated to the retransfusion were found. The need of transfusion was reduced for patients with knee arthroplasty about 30% and for hip arthroplasty about 25%. The retransfusion of unwashed drainage blood is a sufficient method to reduce perioperative homologous blood transfusion in patients with arthroplasty of hip and knee. Substantial complications were not observed, so that this method seems to be save enough for clinical usage. The method is easy to handle and usable without special technical devices. The autologous retransfusion of drainage blood can contribute to lower costs in patients treatement.  相似文献   

18.
Accuracy of an image-free cup navigation system--an anatomical study]   总被引:2,自引:0,他引:2  
The position of the acetabular cup is of decisive importance for the function of a total hip replacement (THR). Using the conventional surgical technique, correct placement of the cup often fails due to a lack of information about pelvic tilt. With CT-based and fluoroscopically-assisted navigation procedures the accuracy of implantation has been significantly improved. However, additional radiation exposure, high cost and the increased time requirement have hampered the acceptance of these techniques. The present anatomical study evaluates the accuracy of an alternative procedure--image-free navigation. This method requires little extra effort, does not substantially delay surgery, and needs no additional imaging. Press-fit cups were implanted in 10 human cadaveric hips with the help of the image-free navigation system, and the position of the cups was checked intraoperatively with a CT-based navigation system and postoperatively by computed tomography. All cups were implanted within the targeted safe zone with an average inclination of 44 degrees (range 40 degrees-48 degrees, SABW 2.7 degrees) and an average anteversion of 18 degrees (range 12-24 degrees, SABW 4.1 degrees). Analysis of accuracy of the image-free navigation software revealed only a small, clinically tolerable deviation in cup anteversion and cup inclination in comparison with the CT-based navigation system and the post operative CT scans. The evaluated image-free navigation system appears to be a practicable and reliable alternative to the computer-assisted implantation of acetabular cups in total hip arthroplasty.  相似文献   

19.
Little is known about the mechanics of in vivo loading on total wrist prostheses where many studies have looked at the mechanics of other types of arthroplasty such as for the hip and the knee which has contributed to the overall success of these types of procedures. Currently surgeons would prefer to carry out arthrodesis on the wrist rather than consider arthroplasty as clinical data have shown that the outcome of total wrist arthroplasty is poorer than compared to the hip and knee. More research is needed on the loading mechanisms of the implants in order to enhance the design of future generation implants. This study looks at the load transfer characteristics of the Universal 2 implant using a finite element model of a virtually implanted prosthesis during gripping. The results showed that the loading on the implant is higher on the dorsal and ulnar aspect than on the volar and radial aspect of the implant. The whole load is transmitted through the radius and none through the ulna.  相似文献   

20.
摘要 目的:比较单踝关节置换术(UKA)和全膝关节置换术(TKA)治疗老年膝内侧间室骨关节炎的疗效。方法:选取2020年1月~2022年6月本院收治的100例老年膝内侧间室骨关节炎患者为研究对象,随机(随机数字表法)分为UKA组(n=50)和TKA组(n=50),采取相应手术方法治疗。比较两组手术相关指标、美国特种外科医院(HSS)膝关节功能评分、膝关节屈伸活动度(ROM)、疼痛视觉模拟评分法(VAS)、健康调查12条简表(SF-12)评分及假体情况。结果:与TKA组相比,UKA组切口长度更短,术中出血量及术后引流量更少,手术时间、下地行走时间及住院时间更短,组间比较差异均有统计学意义(P<0.05)。UKA组术后2周、3个月及6个月时HSS评分均明显高于TKA组(P<0.05)。UKA组术后2周、3个月ROM均明显高于TKA组(P<0.05)。UKA组术后3个月VAS评分明显低于TKA组(P<0.05)。两组SF-12评分中生理及心理维度评分在术后6个月后均明显提高(P<0.05);但组间比较差异均无统计学意义(P>0.05)。两组均无假体翻修病例。结论:UKA相比于TKA具有创伤更小、患者术后恢复更快、膝关节功能恢复更好的优势。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号