首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Flush-mounted hot film anemometer accuracy in pulsatile flow   总被引:2,自引:0,他引:2  
The accuracy of a flush-mounted hot film anemometer probe for wall shear stress measurements in physiological pulsatile flows was evaluated in fully developed pulsatile flow in a rigid straight tube. Measured wall shear stress waveform based on steady flow anemometer probe calibrations were compared to theoretical wall shear stress waveforms based on well-established theory and measured flow rate waveforms. The measured and theoretical waveforms were in close agreement during systole (average deviation of 14 percent at peak systole). As expected, agreement was poor during diastole because of flow reversal and diminished frequency response at low shear rate.  相似文献   

2.
Partial expiratory flow-volume (PEFV) curves in infants are generated by applying a compressive pressure over the chest wall with an inflatable jacket. This study addresses two issues: pressure transmission to and across the chest wall and whether flow limitation can be identified. Eleven infants sedated with chloral hydrate were studied. Pressure transmission to the chest wall, measured with neonatal blood pressure cuffs placed on the infant's body surface, was 72 +/- 4% of jacket pressure during compression maneuvers. The pressure transmission to the air spaces, determined by measuring airway pressure during a compression maneuver against an occluded airway, was 56 +/- 6% of jacket pressure. A significant amount of the applied pressure is therefore lost across both the jacket and chest wall. Rapid pressure oscillations (RPO) were superimposed on static jacket pressures while expiratory flow was measured. Absence of associated oscillations of flow measured at the mouth was taken to indicate that flow was independent of driving pressure and therefore limited. Flow limitation was demonstrable with the RPO technique in all infants for jacket pressures greater than 50 cmH2O; however, it was evident at jacket pressures less than 30 cmH2O jacket pressure in four infants with obstructive airway disease. The RPO technique is a useful adjunct to the compression maneuver utilized to generate PEFV curves in infants because it facilitates the recognition of expiratory flow limitation.  相似文献   

3.
The study of steady and unsteady oscillatory static fluid pressures acting on the internal wall of a collapsible tube is essential for investigation of the complicated behavior observed when a flow is conveyed inside a tube. To examine the validity of two one-dimensional nonsteady theoretical flow models, this paper presents basic experimental observations of flow separation and reattachment and measured data on the static pressure distributions of the flow in a quasi-two-dimensional channel with a throat, together with information on the corresponding shape of the wall deflection and motion. For combinations of moderate Reynolds numbers and angles of the divergent segment of the channel, a smooth flow is separated from the wall downstream of the minimum cross section and reattached to the wall farther downstream. The measured data are compared with numerical results calculated by the two flow models.  相似文献   

4.
This study examines the effect of aneurysmal wall elasticity on the structure of flow within an elastic aneurysm during pulsatile flow. We visualized flow structure in a model of an elastic saccular aneurysm located at the bifurcation of the anterior cerebral artery and extending to the anterior communicating artery, and measured changes in the diameter of the aneurysm wall during pulsatile flow using particle imaging velocimetry (PIV). We similarly measured these features during steady flow by PIV and found that dilation of the aneurysmal wall absorbed the dynamic energy within the aneurysm. Accordingly, aneurysm wall elasticity functions as a biocompatible reaction that relieves wall shear stress acting on the vascular wall during pulsatile flow, and should thus inhibit the development and rupture of an aneurysm.  相似文献   

5.
Pulsatile flow development past a caged ball valve in a model human aorta was studied using laser Doppler anemometry. Velocity profiles measured in the ascending aorta and in the mid-arch region were strongly influenced by the geometry of the valve at the root of the aorta. Velocity profiles distal to the valve were asymmetric with jet-like flow in the peripheral region having larger velocity magnitudes towards the left lateral wall. In early diastole, a streamwise vortex motion was observed throughout the model aorta with fluid moving towards the downstream direction along the left lateral wall and reversed flow along the right lateral wall. With the caged ball valve at the root of the aorta, no reversed flow was observed along the inner wall of curvature in the mid-arch region.  相似文献   

6.
Human sperm motility response to three mechanical stimuli, gravity, fluid flow shear and rigid boundaries, was measured in a tube of 310 X 400 microns calibre. Data were gathered by cine recordings at various focussing levels d across the tube and analysed with a computerized image analysis system. The most influential stimulus was the tube wall near (more than 'at') which the swimmers tended to accumulate, leaving the fluid beyond 100 microns from the wall (d = 100) vacant of motile spermatozoa. The boundary effect was evident as soon as the spermatozoa could be viewed after loading, and accumulation, measured as frequency, as a function of d did not change with time t. This response was not significantly altered by the addition of laminar flow with a centre line velocity of about 400 microns/sec. In flow shear, spermatozoa aligned positively (in the flow direction) at the wall but negatively by about 30 microns from the wall where the velocity gradient (= shear rate) was about 3.5 sec-1. The response to gravity was relatively weak with 11 spermatozoa positive (swimming downwards) for each 9 negative. Neither the boundary effect nor the 'rheotaxic' effect were influenced by gravity as there was no statistical difference in orientation or distribution patterns between vertically and horizontally flowing suspensions. It is suggested that the boundary effect cannot be ignored in in-vitro manipulations, particularly when spermatozoa are observed or extracted. Its importance in vivo lies in the degree to which the tubes transporting motile spermatozoa seem to have mechanisms for reversing the wall accumulation tendency.  相似文献   

7.
The pulsatile flow in an anatomically realistic compliant human carotid bifurcation was simulated numerically. Pressure and mass flow waveforms in the carotid arteries were obtained from an individual subject using non-invasive techniques. The geometry of the computational model was reconstructed from magnetic resonance angiograms. Maps of time-average wall shear stress, contours of velocity in the flow field as well as wall movement and tensile stress on the arterial wall are all presented. Inconsistent with previous findings from idealised geometry models, flow in the carotid sinus is dominated by a strong helical flow accompanied by a single secondary vortex motion. This type of flow is induced primarily by the asymmetry and curvature of the in vivo geometry. Flow simulations have been carried out under the rigid wall assumption and for the compliant wall, respectively. Comparison of the results demonstrates the quantitative influence of the vessel wall motion. Generally there is a reduction in the magnitude of wall shear stress, with its degree depending on location and phase of the cardiac cycle. The region of slow or reversed flow was greater, in both spatial and temporal terms in the compliant model, but the global characteristics of the flow and stress patterns remain unchanged. The analysis of mechanical stresses on the vessel surface shows a complicated stress field. Stress concentration occurs at both the anterior and posterior aspects of the proximal internal bulb. These are also regions of low wall shear stress. The comparison of computed and measured wall movement generally shows good agreement.  相似文献   

8.
T Yamaguchi  S Hanai 《Biorheology》1988,25(1-2):31-36
An electrochemical surface shear stress measurement was applied to a model of very thin unilateral arterial stenosis (height of 1/8 of the model pipe diameter with very smooth surface). Three dimensional wall shear stress distribution was measured under steady flow field from a relatively low Reynolds number, Re = 270, to a high Reynolds number, Re = 1200. There was a characteristic high and low wall shear distribution pattern around the stenosis. There were also remarkable high shear stress areas on the opposite wall and both side walls of the stenosis. It was clearly shown that three dimensional structure of the flow field, hence, the wall shear stress distribution, is affected by a minimal change on the arterial wall.  相似文献   

9.
A microscopic velocimetry technique for evaluating the flow field over cultured endothelial cells was developed. Flow around a cell model scaled up by a factor of 100 was visualized by using an optical microscope and was quantified by using particle-tracking velocimetry. Wall shear stress on the model surface was determined from a two-dimensional velocity field interpolated from measured velocity vectors. Accuracy of the velocimetry was verified by measuring the flow over a sinusoidal cell model that had a wall shear stress profile analytically determined with linear perturbation theory. Comparison of the experimental results with the analytical solution revealed that the total error of the measured wall shear stress was 6 percent.  相似文献   

10.
Steady flow measurements were carried out in a rigid three-dimensional model of the human carotid artery bifurcation at a Reynolds number of 640 and a flow division ratio of 50/50. Both axial and secondary velocities were measured with a laser-Doppler anemometer. In the bulb opposite to the flow divider a zone with negative axial velocities was found with a maximal diameter of about 60% of the local diameter of the branch and a cross-sectional extent of about 25% of the local cross-sectional area. In the bulb the maximum axial velocity shifted towards the divider wall and at the end of the bulb an axial velocity plateau arose near the non-divider wall. Halfway through the bulb, secondary flow showed a vortex through which fluid flowed towards the divider wall near the bifurcation plane and back towards the non-divider wall near the upper walls.  相似文献   

11.
The compliance of the vessel wall affects hemodynamic parameters which may alter the permeability of the vessel wall. Based on experimental measurements, the present study established a finite element (FE) model in the proximal elastic vessel segments of epicardial right coronary arterial (RCA) tree obtained from computed tomography. The motion of elastic vessel wall was measured by an impedance catheter and the inlet boundary condition was measured by an ultrasound flow probe. The Galerkin FE method was used to solve the Navier–Stokes and Continuity equations, where the convective term in the Navier–Stokes equation was changed in the arbitrary Lagrangian–Eulerian (ALE) framework to incorporate the motion due to vessel compliance. Various hemodynamic parameters (e.g., wall shear stress—WSS, WSS spatial gradient—WSSG, oscillatory shear index—OSI) were analyzed in the model. The motion due to vessel compliance affects the time-averaged WSSG more strongly than WSS at bifurcations. The decrease of WSSG at flow divider in elastic bifurcations, as compared to rigid bifurcations, implies that the vessel compliance decreases the permeability of vessel wall and may be atheroprotective. The model can be used to predict coronary flow pattern in subject-specific anatomy as determined by noninvasive imaging.  相似文献   

12.
T Yamaguchi  S Hanai 《Biorheology》1987,24(6):753-762
An electrochemical surface shear stress measurement was applied to a model of unilateral arterial stenosis. The unilateral stenosis model was made up of a removable stenosis plug, in an electrochemical shear stress measurement test section with 100 cathodes. Three dimensional wall shear stress distribution was measured under steady flow field. At a relatively low Reynolds number, Re = 270, there was a characteristic high and low wall shear distribution pattern downstream of the unilateral stenosis. There were also remarkable high shear stress areas on the opposite wall up- and downstream, and both side walls of the stenosis upstream. It was clearly shown that detailed three dimensional structure of the flow field must be studied in order to correlate it to pathological findings.  相似文献   

13.
Laser Doppler anemometry experiments and finite element simulations of steady flow in a three dimensional model of the carotid bifurcation were performed to investigate the influence of non-Newtonian properties of blood on the velocity distribution. The axial velocity distribution was measured for two fluids: a non-Newtonian blood analog fluid and a Newtonian reference fluid. Striking differences between the measured flow fields were found. The axial velocity field of the non-Newtonian fluid was flattened, had lower velocity gradients at the divider wall, and higher velocity gradients at the non-divider wall. The flow separation, as found with the Newtonian fluid, was absent. In the computations, the shear thinning behavior of the analog blood fluid was incorporated through the Carreau-Yasuda model. The viscoelastic properties of the fluid were not included. A comparison between the experimental and numerical results showed good agreement, both for the Newtonian and the non-Newtonian fluid. Since only shear thinning was included, this seems to be the dominant non-Newtonian property of the blood analog fluid under steady flow conditions.  相似文献   

14.
Rigid and compliant casts of a human aortic bifurcation were subjected to physiologically realistic pulsatile fluid flows. At a number of sites near the wall in the approximate median plane of the bifurcation of these models, fluid velocity was measured with a laser Doppler velocimeter, and wall motion (in the case of the compliant cast) was determined with a Reticon linescan camera. The velocity and wall motion data were combined to estimate the instantaneous shear rates at the cast wall. Analysis showed that at the outer walls the cast compliance reduced shear rates, while at the walls of the flow divider the shear rate was increased.  相似文献   

15.
The effects of intra-arterial administration of substance P upon intestinal blood flow, oxygen consumption, intestinal motor activity, and distribution of blood flow to the compartments of the gut wall were measured in anesthetized dogs. Blood flow to the segment of distal ileum was measured with an electromagnetic blood flow meter and A-VO2 was measured spectrophotometrically. Oxygen uptake was calculated as the product of A-VO2 and total blood flow. The clearance of 86Rb was measured to estimate the density of the perfused intestinal capillaries. Changes in blood flow distribution were estimated from the distribution of radiolabeled microspheres. Motor activity was monitored from changes in intraluminal pressure. Substance P induced a dose-related increase in intestinal blood flow, oxygen consumption, and intestinal motor activity. A significant increase in 86Rb clearance and increase in blood flow to the muscles was also observed. The results of these studies indicate that substance P relaxes intestinal arterioles and precapillary sphincters thereby inducing intestinal hyperemia and increased oxygen consumption. These changes, at least in part, might be due to the increased intestinal motility with enhanced metabolic demands of the muscularis for oxygen.  相似文献   

16.
An important number of surgical procedures for creation of vascular access (VA) in haemodialysis patients still results in non-adequate increase in blood flow (non-maturation). The rise in blood flow in arteriovenous shunts depends on vascular remodelling. Computational tools to predict the outcome of VA surgery would be important in this clinical context. The aim of our investigation was then to develop a 0D/1D computational model of arm vasculature able to simulate vessel wall remodelling and related changes in blood flow. We assumed that blood vessel remodelling is driven by peak wall shear stress. The model was calibrated with previously reported values of radial artery diameter and blood flow after end-to-end distal fistula creation. Good agreement was obtained between predicted changes in VA flow and in arterial diameter after surgery and corresponding measured values. The use of this computational model may allow accurate vascular surgery planning and ameliorate VA surgery outcomes.  相似文献   

17.
Concentration polarization of atherogenic lipids in the arterial system   总被引:2,自引:0,他引:2  
Nomenclature c, Normalized LDL concentration (C*/C0); C0, incoming (bulk) LDL concentration (gr/cm3); Cw, LDL concentration on the luminal surface (gr/cm3); ,wC time average value of LDL concentration on the luminal surface (gr/cm3); D, diffusion coef-ficient of LDL (cm2/s); Q, blood flow rate (mL/s); 0R, average internal radius of the artery (cm); Re, Reynolds number (002/Run); Sc, Schmidt number (/Dn); t, normalized time (00*/tuR); u, normalized axial velocity (0*/uu); 0u, time a…  相似文献   

18.
A simplified in vitro model of the spinal canal, based on in vivo magnetic resonance imaging, was used to examine the hydrodynamics of the human spinal cord and subarachnoid space with syringomyelia. In vivo magnetic resonance imaging (MRI) measurements of subarachnoid (SAS) geometry and cerebrospinal fluid velocity were acquired in a patient with syringomyelia and used to aid in the in vitro model design and experiment. The in vitro model contained a fluid-filled coaxial elastic tube to represent a syrinx. A computer controlled pulsatile pump was used to subject the in vitro model to a CSF flow waveform representative of that measured in vivo. Fluid velocity was measured at three axial locations within the in vitro model using the same MRI scanner as the patient study. Pressure and syrinx wall motion measurements were conducted external to the MR scanner using the same model and flow input. Transducers measured unsteady pressure both in the SAS and intra-syrinx at four axial locations in the model A laser Doppler vibrometer recorded the syrinx wall motion at 18 axial locations and three polar positions. Results indicated that the peak-to-peak amplitude of the SAS flow waveform in vivo was approximately tenfold that of the syrinx and in phase (SAS approximately 5.2 +/- 0.6 ml/s, syrinx approximately 0.5 +/- 0.3 ml/s). The in vitro flow waveform approximated the in vivo peak-to-peak magnitude (SAS approximately 4.6 +/- 0.2 ml/s, syrinx approximately 0.4 +/- 0.3 ml/s). Peak-to-peak in vitro pressure variation in both the SAS and syrinx was approximately 6 mm Hg. Syrinx pressure waveform lead the SAS pressure waveform by approximately 40 ms. Syrinx pressure was found to be less than the SAS for approximately 200 ms during the 860-ms flow cycle. Unsteady pulse wave velocity in the syrinx was computed to be a maximum of approximately 25 m/s. LDV measurements indicated that spinal cord wall motion was nonaxisymmetric with a maximum displacement of approximately 140 microm, which is below the resolution limit of MRI. Agreement between in vivo and in vitro MR measurements demonstrates that the hydrodynamics in the fluid filled coaxial elastic tube system are similar to those present in a single patient with syringomyelia. The presented in vitro study of spinal cord wall motion, and complex unsteady pressure and flow environment within the syrinx and SAS, provides insight into the complex biomechanical forces present in syringomyelia.  相似文献   

19.
Numerical analysis of flow phenomena and wall shear stresses in the human carotid artery bifurcation has been carried out using a three-dimensional geometrical model. The primary aim of this study is the detailed discussion of non-Newtonian flow velocity and wall shear stress during the pulse cycle. A comparison of non-Newtonian and Newtonian results is also presented. The applied non-Newtonian behavior of blood is based on measured dynamic viscosity. In the foreground of discussion are the flow characteristics in the carotid sinus. The investigation shows complex flow patterns especially in the carotid sinus where flow separation occurs at the outer wall throughout the systolic deceleration phase. The changing sign of the velocity near the outer sinus wall results in oscillating shear stress during the pulse cycle. At the outer wall of the sinus at maximum diameter level the shear stress ranges from -1.92 N/m2 to 1.22 N/m2 with a time-averaged value of 0.04 N/m2. At the inner wall of the sinus at maximum diameter level the shear stress range is from 1.16 N/m2 to 4.18 N/m2 with a mean of 1.97 N/m2. The comparison of non-Newtonian and Newtonian results indicates unchanged flow phenomena and rather minor differences in the basic flow characteristics.  相似文献   

20.
The three dimensionally curved aortic arch is modeled as a portion of a helical pipe. Pulsatile blood flow therein is calculated assuming helical symmetry and an experimentally measured pressure pulse. Appropriate values for the Womersley and Reynolds numbers are taken from allometric scaling relations for a variety of body masses. The flow structure is discussed with particular reference to the wall shear, which is believed to be important in the inhibition of atheroma. It is found that nonplanar curvature limits the severity of flow separation at the inner bend, and reduces spatial variation of wall shear.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号