首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
At mechanical equilibrium, articular cartilage is usually characterized as an isotropic elastic material with no interstitial fluid flow. In this study, the equilibrium properties (Young's modulus, aggregate modulus and Poisson's ratio) of bovine humeral, patellar and femoral cartilage specimens (n=26) were investigated using unconfined compression, confined compression, and indentation tests. Optical measurements of the Poisson's ratio of cartilage were also carried out. Mean values of the Young's modulus (assessed from the unconfined compression test) were 0.80+/-0.33, 0.57+/-0.17 and 0.31+/-0.18MPa and of the Poisson's ratio (assessed from the optical test) 0.15+/-0.06, 0.16+/-0.05 and 0.21+/-0.05 for humeral, patellar, and femoral cartilages, respectively. The indentation tests showed 30-79% (p<0.01) higher Young's modulus values than the unconfined compression tests. In indentation, values of the Young's modulus were independent of the indenter diameter only in the humeral cartilage. The mean values of the Poisson's ratio, obtained indirectly using the mathematical relation between the Young's modulus and the aggregate modulus in isotropic material, were 0.16+/-0.06, 0.21+/-0.05, and 0.26+/-0.08 for humeral, patellar, and femoral cartilages, respectively. We conclude that the values of the elastic parameters of the cartilage are dependent on the measurement technique in use. Based on the similar values of Poisson's ratios, as determined directly or indirectly, the equilibrium response of articular cartilage under unconfined and confined compression is satisfactorily described by the isotropic elastic model. However, values of the isotropic Young's modulus obtained from the in situ indentation tests are higher than those obtained from the in vitro unconfined or confined compression tests and may depend on the indenter size in use.  相似文献   

2.
Jet injectors employ high-velocity liquid jets that penetrate into human skin and deposit drugs in the dermal or subdermal region. Although jet injectors have been marketed for a number of years, relatively little is known about the interactions of high-speed jets with soft materials such as skin. Using polyacrylamide gels as a model system, the mechanics of jet penetration, including the dependence of jet penetration on mechanical properties, was studied. Jets employed in a typical commercial injector, (orifice diameter: 152 microm, velocity: 170-180 m/s) were used to inject fluid into polyacrylamide gels possessing Young's moduli in the range of 0.06-0.77 MPa and hardness values in the range of 4-70 H(OO). Motion analysis of jet entry into polyacrylamide gels revealed that jet penetration can be divided into three distinct events: erosion, stagnation, and dispersion. During the erosion phase, the jet removed the gel at the impact site and led to the formation of a distinct cylindrical hole. Cessation of erosion induced a period of jet stagnation ( approximately 600 micros) characterized by constant penetration depth. This stage was followed by dispersion of the liquid into the gel. The dispersion took place by crack propagation and was nearly symmetrical with the exception of injections into 10% acrylamide (Young's modulus of 0.06 MPa). The penetration depth of the jets as well as the rate of erosion decreased with increasing Young's modulus. The mechanics of jet penetration into polyacrylamide gels provides an important tool for understanding jet injection into skin.  相似文献   

3.
The micropipette aspiration (MA) experiment remains a quite widely used micromanipulation technique for quantifying the elastic modulus of cells and, less frequently, of other biological samples. However, moduli estimations derived from MA experiments are only valid if the probed sample is non-adherent to the rigid substrate. This study extends this standard formulation by taking into account the influence of the sample adhesion. Using a finite element analysis of the sample aspiration into the micropipette, we derived a new expression of the aspirated length for linear elastic materials. Our results establish that (i) below a critical value, the thickness h of the probed sample must be considered to get an accurate value of its Young's modulus (ii) this critical value depends both on the Poisson's ratio and on the sample adhesivity. Additionally, we propose a novel method which allows the computation of the intrinsic Young's modulus of the adherent probed sample from its measured apparent elasticity modulus. Thanks to the set of computational graphs we derived from our theoretical analysis, we successfully validate this method by experiments performed on polyacrylamide gels. Interestingly, the original procedure we proposed allows a simultaneous quantification of the Young's modulus and of the Poisson's ratio of the adherent gel. Thus, our revisited analysis of MA experiments extends the application domain of this technique, while contributing to decrease the dispersion of elastic modulus values obtained by this method.  相似文献   

4.
5.
The Hopkinson bar stress technique and a universal testing machine (Instron 1125) have been used to investigate the dynamic and static mechanical properties of cortical bone taken from a human femur respectively. We found that the average dynamic Young's modulus value (Ed = 19.9 GPa) to be 23% higher than the average static Young's modulus value (Ed = 16.2 GPa). Furthermore, the Poisson's ratio did not exhibit any significant variation for the two different types of loading. No difference was observed between the values of the dynamic Young's modulus in tension and those found in compression. A comparison was made of the results of this study with those found by other researchers using different techniques, such as ultrasonics, and it was found that they agree well with most of the results of previous studies. Finally, the viscosity for cortical bone found in this study correlates with viscosity reported by Tennyson et al. [Expl Mech. 12, 502-507 (1972)] for ten days post mortem age specimens.  相似文献   

6.
The biomechanical functions of articular cartilage are governed largely by the composition and density of its specialized extracellular matrix. Relationships between matrix density and functional indices such as mechanical properties or interstitial solute diffusivities have been previously explored. However, direct correlations between mechanical properties and solute transport parameters have received less attention, despite potential application of this information for cartilage functional assessment both in vivo and in vitro. The objective of this study was therefore to examine relationships among solute diffusivities, mechanical properties, and matrix density of compressed articular cartilage. Matrix density varied due to natural variation among explants and due to applied static compression. Matrix density of statically compressed cartilage explants was characterized by glycoaminoglycan (GAG) weight fraction and fluid volume fraction, while diffusion coefficients of a wide range of solutes were measured to characterize the transport environment. Explant mechanical properties were characterized by a non-linear Young's modulus (axial stress-strain ratio) and a non-linear Poisson's ratio (radial-to-axial strain ratio). Solute diffusivities were consistently correlated with Young's modulus, as well as with explant GAG weight and fluid volume fractions. Therefore, in vitro mechanical tests may provide a means of assessing transport environments in cartilage-like materials, while in vivo measurements of solute transport (for example with magnetic resonance imaging) may be a useful complement in identifying localized differences in matrix density and mechanical properties.  相似文献   

7.
Young's modulus and Poisson's ratios of 6mm-sized cubes of equine cortical bone were measured in compression using a micro-mechanical loading device. Surface displacements were determined by electronic speckle pattern-correlation interferometry. This method allows for non-destructive testing of very small samples in water. Analyses of standard materials showed that the method is accurate and precise for determining both Young's modulus and Poisson's ratio. Material properties were determined concurrently in three orthogonal anatomic directions (axial, radial and transverse). Young's modulus values were found to be anisotropic and consistent with values of equine cortical bone reported in the literature. Poisson's ratios were also found to be anisotropic, but lower than those previously reported. Poisson's ratios for the radial-transverse and transverse-radial directions were 0.15+/-0.02, for the axial-transverse and axial-radial directions 0.19+/-0.04, and for the transverse-axial and radial-axial direction 0.09+/-0.02 (mean+/-SD). Cubes located only millimetres apart had significantly different elastic properties, showing that significant spatial variation occurs in equine cortical bone.  相似文献   

8.
Different RIA systems available for measuring the concentrations of pregnancy-associated glycoproteins (PAGs) in dairy goats were compared in order to evaluate their accuracy in early pregnancy diagnosis. Plasma concentrations of PAGs were determined by 3 heterologous RIA systems with a bovine PAG standard and tracer in combination with antisera anti-ovine PAG (RIA 1), anti-caprine PAG55 + 62 (RIA 2), anti-caprine PAG55 + 59 (RIA 3), and by 2 homologous RIA systems that employed caprine PAG55 + 62 and caprine PAG55 + 59 and their specific antisera (RIAs 4 and 5, respectively). In all of the RIAs, the mean concentrations of PAGs were significantly higher (P < 0.01) in pregnant than in nonpregnant goats from Day 21 onwards after breeding. On Day 21, the accuracy rates of early pregnancy diagnoses were 56% (RIA 1), 96% (RIA 2), 99% (RIA 3), 95% (RIA 4) and 90% (RIA 5), whereas on Day 28 these rates were > 99% for RIAs 2, 3, 4 and 5. The RIAs for PAGs depend on proteins from the placenta being present in maternal plasma and require only a single sample of blood, to distinguish pregnant goats from those that fail to return to estrus for other reasons. The homologous and semi-heterologous assays are highly accurate as early as Day 21 of pregnancy.  相似文献   

9.
The tensile stiffness of tissue grown from chondrocyte culture was both measured experimentally and predicted using a composites model theory relating tissue microstructure to macroscopic material stiffness. The tissue was altered by several treatment protocols to provide a wide range of collagen fibril volume fraction (0.015-0.15). The rate of change of tissue modulus with change in collagen volume fraction predicted by the theory was within 14% of the slope of the linear fit through the experimental data, without the use of fitting parameters for the theoretical value of the slope. Use of the model to simulate cytokine mediated tissue digestion suggests that the action of IL-1beta and retinoic acid is mainly removal of proteoglycans and some removal of collagen. The model also indicates that the matrix and collagen remaining in the tissue has the same elastic properties as the untreated tissue, and is not damaged due to the alteration. Young's modulus of the collagen fibrils is predicted to be 120 MPa, a value in the range of previous studies. This value is dependent mainly on the matrix modulus and collagen fibril volume fraction and not on Poisson's ratio of either matrix or fibril. Poisson's ratio of the tissue depends primarily on the Poisson's ratio of the matrix.  相似文献   

10.
PURPOSE: In a meta-analysis of the literature we evaluated the present knowledge of the material properties of cortical and cancellous bone to answer the question whether the available data are sufficient to realize anisotropic finite element (FE)-models of the proximal femur. MATERIAL AND METHOD: All studies that met the following criteria were analyzed: Young's modulus, tensile, compressive and torsional strengths, Poisson's ratio, the shear modulus and the viscoelastic properties had to be determined experimentally. The experiments had to be carried out in a moist environment and at room temperature with freshly removed and untreated human cadaverous femurs. All material properties had to be determined in defined load directions (axial, transverse) and should have been correlated to apparent density (g/cm(3)), reflecting the individually variable and age-dependent changes of bone material properties. RESULTS: Differences in Young's modulus of cortical [cancellous] bone at a rate of between 33% (58%) (at low apparent density) and 62% (80%) (at high apparent density), are higher in the axial than in the transverse load direction. Similar results have been seen for the compressive strength of femoral bone. For the tensile and torsional strengths, Poisson's ratio and the shear modulus, only ultimate values have been found without a correlation to apparent density. For the viscoelastic behaviour of bone only data of cortical bone and in axial load direction have been described up to now. CONCLUSIONS: Anisotropic FE-models of the femur could be realized for most part with the summarized material properties of bone if characterized by apparent density and load directions. Because several mechanical properties have not been correlated to these main criteria, further experimental investigations will be necessary in future.  相似文献   

11.
Quantitative magnetic resonance imaging (MRI) is the most potential non-invasive means for revealing the structure, composition and pathology of articular cartilage. Here we hypothesize that cartilage mechanical properties as determined by the macromolecular framework and their interactions can be accessed by quantitative MRI. To test this, adjacent cartilage disk pairs (n=32) were prepared from bovine proximal humerus and patellofemoral surfaces. For one sample, the tissue Young's modulus, aggregate modulus, dynamic modulus and Poisson's ratio were determined in unconfined compression. The adjacent disk was studied at 9.4T to determine the tissue T(2) relaxation time, sensitive to the integrity of the collagen network, and T(1) relaxation time in the presence of Gd-DTPA, a technique developed for the estimation of cartilage proteoglycan (PG) content. Quantitative MRI parameters were able to explain up to 87% of the variations in certain biomechanical parameters. Correlations were further improved when data from the proximal humerus was assessed separately. MRI parameters revealed a topographical variation similar to that of mechanical parameters. Linear regression analysis revealed that Young's modulus of cartilage may be characterized more completely by combining both collagen- and PG-sensitive MRI parameters. The present results suggest that quantitative MRI can provide important information on the mechanical properties of articular cartilage. The results are encouraging with respect to functional imaging of cartilage, although in vivo applicability may be limited by the inferior resolution of clinical MRI instruments.  相似文献   

12.
The mechanical properties of cells are unique indicators of their states and functions. Though, it is difficult to recognize the degrees of mechanical properties, due to small size of the cell and broad distribution of the mechanical properties. Here, we developed a simple virtual reality system for presenting the mechanical properties of cells and their dispersion using a haptic device and a PC. This system simulates atomic force microscopy (AFM) nanoindentation experiments for floating cells in virtual environments. An operator can virtually position the AFM spherical probe over a round cell with the haptic handle on the PC monitor and feel the force interaction. The Young's modulus of mesenchymal stem cells and HEK293 cells in the floating state was measured by AFM. The distribution of the Young's modulus of these cells was broad, and the distribution complied with a log-normal pattern. To represent the mechanical properties together with the cell variance, we used log-normal distribution-dependent random number determined by the mode and variance values of the Young's modulus of these cells. The represented Young's modulus was determined for each touching event of the probe surface and the cell object, and the haptic device-generating force was calculated using a Hertz model corresponding to the indentation depth and the fixed Young's modulus value. Using this system, we can feel the mechanical properties and their dispersion in each cell type in real time. This system will help us not only recognize the degrees of mechanical properties of diverse cells but also share them with others.  相似文献   

13.
Pregnancy-associated glycoproteins (PAGs) are a large grouping of placental proteins that belong to the aspartic peptidase gene family. Although useful to detect pregnancy in ruminant species, the function of these molecules is unclear. Several PAGs expressed by trophoblast binucleate cells can enter the maternal circulation, suggesting that they could have a systemic role in altering maternal physiology. The objective of this work was to examine whether these circulating placental antigens were important in pregnancy by actively immunizing ewes against them. PAGs were purified by pepstatin-affinity chromatography and conjugated to the immunogenic protein, keyhole limpet hemocyanin (KLH). Ewes were immunized with PAG-KLH conjugate (n = 22) or with KLH alone (n = 9), and bred to intact rams. Blood samples, collected on Day 0 (day of estrus), Day 10, Days 15 to 25 and weekly throughout pregnancy, were analyzed for PAG by an ELISA. On Day 30, pregnancy was confirmed by ultrasound. Ewes immunized against PAG-KLH produced a range of reactive anti-PAG titers, whereas all immunized ewes had high anti-KLH immunoreactivity. PAGs became detectable in the anti-KLH (control) ewes at Day 21.6 ± 2.2 of pregnancy. Those ewes immunized against PAGs (n = 7), that had very low immunoreactivity toward PAGs, had measurable PAG by Day 22.9 ± 1.3, and their PAG serum profiles throughout pregnancy did not differ from the controls. Those exhibiting moderate to high anti-PAG immunoreactivity (n = 15), had significantly lower PAG concentrations than controls, with antigen not becoming detectable until Day 48.1 ± 15.6. The decrease in circulating PAG in the immunized animals did not correlate with changes in pregnancy rates, lamb number or lamb birth weight. These results suggest that while PAGs may play a role in maintaining pregnancy, their major contribution is likely to be at the fetal-maternal interface. Their actions at extra-placental sites are presumably of more secondary importance.  相似文献   

14.
Unconfined compression test has been frequently used to study the mechanical behaviors of articular cartilage, both theoretically and experimentally. It has also been used in explant and gel-cell-complex studies in tissue engineering. In biphasic and poroelastic theories, the effect of charges fixed on the proteoglycan macromolecules in articular cartilage is embodied in the apparent compressive Young's modulus and the apparent Poisson's ratio of the tissue, and the fluid pressure is considered to be the portion above the osmotic pressure. In order to understand how proteoglycan fixed charges might affect the mechanical behaviors of articular cartilage, and in order to predict the osmotic pressure and electric fields inside the tissue in this experimental configuration, it is necessary to use a model that explicitly takes into account the charged nature of the tissue and the flow of ions within its porous interstices. In this paper, we used a finite element model based on the triphasic theory to study how fixed charges in the porous-permeable soft tissue can modulate its mechanical and electrochemical responses under a step displacement in unconfined compression. The results from finite element calculations showed that: 1) A charged tissue always supports a larger load than an uncharged tissue of the same intrinsic elastic moduli. 2) The apparent Young's modulus (the ratio of the equilibrium axial stress to the axial strain) is always greater than the intrinsic Young's modulus of an uncharged tissue. 3) The apparent Poisson's ratio (the negative ratio of the lateral strain to the axial strain) is always larger than the intrinsic Poisson's ratio of an uncharged tissue. 4) Load support derives from three sources: intrinsic matrix stiffness, hydraulic pressure and osmotic pressure. Under the unconfined compression, the Donnan osmotic pressure can constitute between 13%-22% of the total load support at equilibrium. 5) During the stress-relaxation process following the initial instant of loading, the diffusion potential (due to the gradient of the fixed charge density and the associated gradient of ion concentrations) and the streaming potential (due to fluid convection) compete against each other. Within the physiological range of material parameters, the polarity of the electric potential depends on both the mechanical properties and the fixed charge density (FCD) of the tissue. For softer tissues, the diffusion effects dominate the electromechanical response, while for stiffer tissues, the streaming potential dominates this response. 6) Fixed charges do not affect the instantaneous strain field relative to the initial equilibrium state. However, there is a sudden increase in the fluid pressure above the initial equilibrium osmotic pressure. These new findings are relevant and necessary for the understanding of cartilage mechanics, cartilage biosynthesis, electromechanical signal transduction by chondrocytes, and tissue engineering.  相似文献   

15.
There is an increased need for alginate materials with both enhanced and controllable mechanical properties in the fields of food, pharmaceutical and specialty applications. In the present work, well-characterized algal polymers and mannuronan were enzymatically modified using C-5 epimerases converting mannuronic acid residues to guluronic acid in the polymer chain. Composition and sequential structure of controls and epimerized alginates were analyzed by (1)H NMR spectroscopy. Mechanical properties of Ca-alginate gels were further examined giving Young's modulus, syneresis, rupture strength, and elasticity of the gels. Both mechanical strength and elasticity of hydrogels could be improved and manipulated by epimerization. In particular, alternating sequences were found to play an important role for the final mechanical properties of alginate gels, and interestingly, a pure polyalternating sample resulted in gels with extremely high syneresis and rupture strength. In conclusion, enzymatic modification was shown to be a valuable tool in modifying the mechanical properties of alginates in a highly specific manner.  相似文献   

16.
We studied the elastic properties of bone to analyze its mechanical behavior. The basic principles of ultrasonic methods are now well established for varying isotropic media, particularly in the field of biomedical engineering. However, little progress has been made in its application to anisotropic materials. This is largely due to the complex nature of wave propagation in these media. In the present study, the theory of elastic waves is essential because it relates the elastic moduli of a material to the velocity of propagation of these waves along arbitrary directions in a solid. Transducers are generally placed in contact with the samples which are often cubes with parallel faces that are difficult to prepare. The ultrasonic method used here is original, a rough preparation of the bone is sufficient and the sample is rotated. Moreover, to analyze heterogeneity of the structure we measure velocities in different points on the sample. The aim of the present study was to determine in vitro the anisotropic elastic properties of cortical bones. For this purpose, our method allowed measurement of longitudinal and transverse velocities (C(L) and C(T)) in longitudinal (fiber direction) and the radial directions (orthogonal to the fiber direction) of compact bones. Young's modulus E and Poisson's ratio nu, were then deduced from the velocities measured considering the compact bone as transversely isotropic or orthotropic. The results are in line with those of other methods.  相似文献   

17.
The effect of immersion into salt solutions on rheological properties of gellan gels was investigated. The storage Young's modulus of gellan gels increased with time during the immersion into salt solutions. The increase of the storage Young's modulus can not be explained solely by change in the concentration of gellan. The ellipticity at 202 nm decreased by the immersion, suggesting the formation and aggregation of gellan helices. It was considered that during immersion cations penetrated into gellan gels to induce the formation and aggregation of gellan helices in gels, resulting in reinforcement of the gel network.  相似文献   

18.
The cytoskeleton is known to play an important role in the biomechanical nature and structure of cells, but its particular function in compressive characteristics has not yet been fully examined. This study focused on the contribution of the main three cytoskeletal elements to the bulk compressive stiffness (as measured by the compressive modulus), volumetric or apparent compressibility changes (as further indicated by apparent Poisson's ratio), and recovery behavior of individual chondrocytes. Before mechanical testing, cytochalasin D, acrylamide, or colchicine was used to disrupt actin microfilaments, intermediate filaments, or microtubules, respectively. Cells were subjected to a range of compressive strains and allowed to recover to equilibrium. Analysis of the video recording for each mechanical event yielded relevant compressive properties and recovery characteristics related to the specific cytoskeletal disrupting agent and as a function of applied axial strain. Inhibition of actin microfilaments had the greatest effect on bulk compressive stiffness (∼50% decrease compared to control). Meanwhile, intermediate filaments and microtubules were each found to play an integral role in either the diminution (compressibility) or retention (incompressibility) of original cell volume during compression. In addition, microtubule disruption had the largest effect on the “critical strain threshold” in cellular mechanical behavior (33% decrease compared to control), as well as the characteristic time for recovery (∼100% increase compared to control). Elucidating the role of the cytoskeleton in the compressive biomechanical behavior of single cells is an important step toward understanding the basis of mechanotransduction and the etiology of cellular disease processes.  相似文献   

19.
The aim of the study was to compare transrectal ultrasound with progesterone (P4) and pregnancy-associated glycoproteins (PAGs) as pregnancy detection methods for semidomesticated reindeer (Rangifer tarandus tarandus) in field conditions. Female reindeer (n = 195) were scanned transrectally by a 7.5-MHz linear array transducer, and blood was sampled either in December 2005 (n = 33), December 2006 (n = 92), or January 2007 (n = 70) during early or mid gestation. Plasma levels of P4 and PAGs were assessed by radioimmunoassay (RIA). Based on calving records, the sensitivity, specificity, predictive values, and the overall accuracy of the three tests were calculated. The overall calving rate calculated from the calving records was 86.2%. The overall accuracy of transrectal ultrasound was 99.5%. The sensitivity and specificity of transrectal ultrasound were 99.4% and 100%, respectively. In the plasma P4 test, the threshold level of 5.0 nmol/L gave the highest overall accuracy (94.9%). The sensitivity of the P4 test decreased from 96.4% to 81.5%, when the threshold level increased from 5.0 nmol/L to 8.0 nmol/L, while the specificity remained at 85.2% over the range of these cutoff values. The overall accuracy of the plasma PAG test decreased from 96.4% to 64.1% when the plasma PAG threshold level increased from 0.5 ng/mL to 3.5 ng/mL, whereas sensitivity decreased from 99.4% to 58.3%. Specificity increased from 77.8% to 100% when the plasma PAG threshold level reached 3.0 ng/mL. Transrectal ultrasound showed higher diagnostic values than those of plasma P4-RIA and PAG-RIA in diagnosing pregnancy of reindeer, with the advantage that diagnoses can be made in real time in field conditions.  相似文献   

20.
《Theriogenology》2010,73(9):1229-1236
The aim of the study was to compare transrectal ultrasound with progesterone (P4) and pregnancy-associated glycoproteins (PAGs) as pregnancy detection methods for semidomesticated reindeer (Rangifer tarandus tarandus) in field conditions. Female reindeer (n = 195) were scanned transrectally by a 7.5-MHz linear array transducer, and blood was sampled either in December 2005 (n = 33), December 2006 (n = 92), or January 2007 (n = 70) during early or mid gestation. Plasma levels of P4 and PAGs were assessed by radioimmunoassay (RIA). Based on calving records, the sensitivity, specificity, predictive values, and the overall accuracy of the three tests were calculated. The overall calving rate calculated from the calving records was 86.2%. The overall accuracy of transrectal ultrasound was 99.5%. The sensitivity and specificity of transrectal ultrasound were 99.4% and 100%, respectively. In the plasma P4 test, the threshold level of 5.0 nmol/L gave the highest overall accuracy (94.9%). The sensitivity of the P4 test decreased from 96.4% to 81.5%, when the threshold level increased from 5.0 nmol/L to 8.0 nmol/L, while the specificity remained at 85.2% over the range of these cutoff values. The overall accuracy of the plasma PAG test decreased from 96.4% to 64.1% when the plasma PAG threshold level increased from 0.5 ng/mL to 3.5 ng/mL, whereas sensitivity decreased from 99.4% to 58.3%. Specificity increased from 77.8% to 100% when the plasma PAG threshold level reached 3.0 ng/mL. Transrectal ultrasound showed higher diagnostic values than those of plasma P4-RIA and PAG-RIA in diagnosing pregnancy of reindeer, with the advantage that diagnoses can be made in real time in field conditions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号