Recent studies have demonstrated that continuous countercurrent tangential chromatography (CCTC) can effectively purify monoclonal antibodies from clarified cell culture fluid. CCTC has the potential to overcome many of the limitations of conventional packed bed protein A chromatography. This paper explores the optimization of CCTC in terms of product yield, impurity removal, overall productivity, and buffer usage. Modeling was based on data from bench‐scale process development and CCTC experiments for protein A capture of two clarified Chinese Hamster Ovary cell culture feedstocks containing monoclonal antibodies provided by industrial partners. The impact of resin binding capacity and kinetics, as well as staging strategy and buffer recycling, was assessed. It was found that optimal staging in the binding step provides better yield and increases overall system productivity by 8–16%. Utilization of higher number of stages in the wash and elution steps can lead to significant decreases in buffer usage (~40% reduction) as well as increased removal of impurities (~2 log greater removal). Further reductions in buffer usage can be obtained by recycling of buffer in the wash and regeneration steps (~35%). Preliminary results with smaller particle size resins show that the productivity of the CCTC system can be increased by 2.5‐fold up to 190 g of mAb/L of resin/hr due to the reduction in mass transfer limitations in the binding step. These results provide a solid framework for designing and optimizing CCTC technology for capture applications. © 2016 American Institute of Chemical Engineers Biotechnol. Prog., 32:430–439, 2016  相似文献   

2.
There is growing interest within the biopharmaceutical industry to improve manufacturing efficiency through process intensification, with the goal of generating more product in less time with smaller equipment. In monoclonal antibody (mAb) purification, a unit operation that can benefit from intensification is anion exchange (AEX) polishing chromatography. Single-pass tangential flow filtration (SPTFF) technology offers an opportunity for process intensification by reducing intermediate pool volumes and increasing product concentration without recirculation. This study evaluated the performance of an AEX resin, both in terms of host cell protein (HCP) purification and viral clearance, following concentration of a mAb feed using SPTFF. Results show that preconcentration of AEX feed material improved isotherm conditions for HCP binding, resulting in a fourfold increase in resin mAb loading at the target HCP clearance level. Excellent clearance of minute virus of mouse and xenotropic murine virus was maintained at this higher load level. The increased mAb loading enabled by SPTFF preconcentration effectively reduced AEX column volume and buffer requirements, shrinking the overall size of the polishing step. In addition, the suitability of SPTFF for extended processing time operation was demonstrated, indicating that this approach can be implemented for continuous biomanufacturing. The combination of SPTFF concentration and AEX chromatography for an intensified mAb polishing step which improves both manufacturing flexibility and process productivity is supported.  相似文献   

3.
Protein A chromatography is widely employed for the capture and purification of monoclonal antibodies (mAbs). Because of the high cost of protein A resins, there is a significant economic driving force to seek new downstream processing strategies. Membrane chromatography has emerged as a promising alternative to conventional resin based column chromatography. However, to date, the application has been limited to mostly ion exchange flow through (FT) mode. Recently, significant advances in Natrix hydrogel membrane has resulted in increased dynamic binding capacities for proteins, which makes membrane chromatography much more attractive for bind/elute operations. The dominantly advective mass transport property of the hydrogel membrane has also enabled Natrix membrane to be run at faster volumetric flow rates with high dynamic binding capacities. In this work, the potential of using Natrix weak cation exchange membrane as a mAb capture step is assessed. A series of cycle studies was also performed in the pilot scale device (> 30 cycles) with good reproducibility in terms of yield and product purities, suggesting potential for improved manufacturing flexibility and productivity. In addition, anion exchange (AEX) hydrogel membranes were also evaluated with multiple mAb programs in FT mode. Significantly higher binding capacity for impurities (support mAb loads up to 10Kg/L) and 40X faster processing speed were observed compared with traditional AEX column chromatography. A proposed protein A free mAb purification process platform could meet the demand of a downstream purification process with high purity, yield, and throughput. © 2015 American Institute of Chemical Engineers Biotechnol. Prog., 31:974–982, 2015  相似文献   

4.
This paper presents a systems approach to evaluating the potential of integrated continuous bioprocessing for monoclonal antibody (mAb) manufacture across a product's lifecycle from preclinical to commercial manufacture. The economic, operational, and environmental feasibility of alternative continuous manufacturing strategies were evaluated holistically using a prototype UCL decisional tool that integrated process economics, discrete‐event simulation, environmental impact analysis, operational risk analysis, and multiattribute decision‐making. The case study focused on comparing whole bioprocesses that used either batch, continuous or a hybrid combination of batch and continuous technologies for cell culture, capture chromatography, and polishing chromatography steps. The cost of goods per gram (COG/g), E‐factor, and operational risk scores of each strategy were established across a matrix of scenarios with differing combinations of clinical development phase and company portfolio size. The tool outputs predict that the optimal strategy for early phase production and small/medium‐sized companies is the integrated continuous strategy (alternating tangential flow filtration (ATF) perfusion, continuous capture, continuous polishing). However, the top ranking strategy changes for commercial production and companies with large portfolios to the hybrid strategy with fed‐batch culture, continuous capture and batch polishing from a COG/g perspective. The multiattribute decision‐making analysis highlighted that if the operational feasibility was considered more important than the economic benefits, the hybrid strategy would be preferred for all company scales. Further considerations outside the scope of this work include the process development costs required to adopt continuous processing. © 2017 The Authors Biotechnology Progress published by Wiley Periodicals, Inc. on behalf of American Institute of Chemical Engineers Biotechnol. Prog., 33:854–866, 2017  相似文献   

5.
Prepacked chromatography columns and cassette filtration units offer many advantages in bioprocessing. These include reduced labor costs and processing times, ease of storage, and enhanced process flexibility. Rectangular formats are particularly attractive as they can be easily stacked and multiplexed together for continuous processing. Cylindrical chromatography beds have dominated bioprocessing even though their bed support and pressure-flow performance vary with bed dimensions. This work presents the performance of novel, rhombohedral chromatography devices with internally supported beds. They are compatible with existing chromatography workstations and can be packed with any standard commercial resin. The devices offer pressure-flow characteristics independent of container-volume, simple multiplexing, and separation performance comparable to cylindrical columns. Their bi-planar, internal bed support allows mechanically less-rigid resins to be used at up to four times higher maximal linear velocities, and productivities approaching 200 g/L/h for affinity resins, compared to the 20 g/L/h typical of many column-based devices. Three 5 L devices should allow processing of up to 3 kg of monoclonal antibody per hour.  相似文献   

6.
An important consideration for integrated continuous biomanufacturing is that the downstream chromatography steps integrated with the bioreactor should maintain a low bioburden state throughout the entire duration of the operation. One potential strategy to achieve this is to start bioburden-free and functionally close the chromatography system. While chromatography skids themselves can be rendered bioburden-free, limitations exist in applying these methods to chromatography columns. The small column sizes used in continuous multicolumn chromatography enable gamma irradiation of disposable columns to render them bioburden-free. However, this approach has not been widely implemented, likely because gamma irradiation can negatively impact resin performance. Here, several protective mobile-phase modifiers were screened and shown to help chromatography resins retain naïve-like performance. Gamma irradiated columns were then integrated into perfusion bioreactors for continuous capture. Successful integrated continuous capture downstream of perfusion bioreactors for greater than 40 days using protein A, custom affinity, and non-affinity capture resins for multiple biologic modalities is demonstrated in development and commercial settings. No indications of time-based performance decline or bioburden growth have been observed. This strategy enables bioburden-free integrated continuous biomanufacturing operations and could allow full process closure and decreased environmental control requirements for facilities; thus, permitting simultaneous multi-product operations in a ballroom arrangement.  相似文献   

7.
Compared to traditional chromatography using resins in packed-bed columns, membrane chromatography is a relatively new and immature bioseparation technology based on the integration of membrane filtration and liquid chromatography into a single-stage operation. Over the past decades, advances in membrane chemistry have yielded novel membrane devices with high binding capacities and improved mass transfer properties, significantly increasing the bioprocessing efficiency for purification of biomolecules. Due to the disposable nature, low buffer consumption, and reduced equipment costs, membrane chromatography can significantly reduce downstream bioprocessing costs. In this review, we discuss technological merits and disadvantages associated with membrane chromatography as well as recent bioseparation applications with a particular attention on purification of large biomolecules.  相似文献   

8.
Ongoing efforts in the biopharmaceutical industry to enhance productivity and reduce manufacturing costs include development of intensified, linked, and/or continuous processes. One approach to improve productivity and process economics of the polishing step (i.e., anion exchange chromatography) is to preconcentrate the product intermediate using a single-pass tangential flow filtration step before loading on the resin. This intensification of the polishing step consequently leads to changes in product intermediate concentration for subsequent virus filtration operations, potentially impacting filter performance and methods for evaluating viral clearance. The filtrate flux performance of a virus filtration operation was evaluated with monoclonal antibody (mAb) solutions of varying concentrations. These data were used to evaluate the effect on filter sizing for a hypothetical mAb perfusion process. The optimum mAb concentration to minimize the area of the virus filter was a function of the filtration step duration and reflected the competing effects of increasing concentration and decreasing volumetric flux on the membrane productivity. mAb solutions at high and low concentrations were used to evaluate viral clearance with extended filtration times (e.g., 24–72 h) simulating continuous processing conditions. Modifications to more traditional filtration viral clearance study methods were required to avoid experimental artifacts associated with the extended filtration time. No virus passage through the filter was observed under these conditions, similar to previous results for batch processes. These data demonstrate the feasibility of obtaining effective virus removal even when mAb concentration and filtrations times are increased by up to an order of magnitude from current common practices.  相似文献   

9.
Truly continuous biomanufacturing processes enable an uninterrupted feed stream throughout the whole production without the need for holding tanks. We have utilized microporous anion and cation exchangers into which only salts, but not proteins, can penetrate into the pores for desalting of protein solutions, while diafiltration or dilution is usually employed for feed adjustments. Anion exchange and cation exchange chromatography columns were connected in series to remove both anions and cations. To increase operation performance, a continuous process was developed comprised of four columns. Continuous mode was achieved by staggered cycle operation, where one set of columns, consisting of one anion exchange and one cation exchange column, was loaded during the regeneration of the second set. Refolding, desalting and subsequent ion exchange capturing with a scFv as the model protein was demonstrated. The refolding solution was successfully desalted resulting in a consistent conductivity below 0.5 mS/cm from initial values of 10 to 11 mS/cm. With continuous operation process time could be reduced by 39% while productivity was increased to 163% compared to batch operation. Desalting of the protein solution resulted in up to 7‐fold higher binding capacities in the subsequent ion exchange capture step with conventional protein binding resins.  相似文献   

10.
A continuous integrated bioprocess available from the earliest stages of process development allows for an easier, more efficient and faster development and characterization of an integrated process as well as production of small-scale drug candidates. The process presented in this article is a proof-of-concept of a continuous end-to-end monoclonal antibody production platform at a very small scale based on a 200 ml alternating tangential flow filtration perfusion bioreactor, integrated with the purification process with a model-based design and control. The downstream process, consisting of a periodic twin-column protein A capture, a virus inactivation, a CEX column and an AEX column, was compactly implemented in a single chromatography system, with a purification time of less than 4 hr. Monoclonal antibodies were produced for 17 days in a high cell density perfusion culture of CHO cells with titers up to 1.0 mg/ml. A digital twin of the downstream process was created by modelling all the chromatography steps. These models were used for real-time decision making by the implementation of control strategies to automatize and optimize the operation of the process. A consistent glycosylation pattern of the purified product was ensured by the steady state operation of the process. Regarding the removal of impurities, at least a 4-log reduction in the HCP levels was achieved. The recovery yield was up to 60%, and a maximum productivity of 0.8 mg/ml/day of purified product was obtained.  相似文献   

11.
Many manufacturers of biopharmaceuticals are moving from batch to continuous processing. While this approach offers advantages over batch processing, demonstration of viral clearance for continuous processes is challenging. Fluctuating output from a continuous process chromatography column results in a nonhomogeneous load for the subsequent column and must be considered when designing viral clearance studies. One approach to clearance studies is to downscale the connected unit operations and introduce virus by in-line spiking. This is challenging to be implemented at the contract research organization performing the clearance study given the complexity of systems and level of expertise required. Alternately, each unit operation could be evaluated in traditional batch mode but the spiking and loading conditions be modified to mimic the variance introduced by the transition between two connected columns. Using a standard chromatography system, we evaluated a flow-through anion exchange chromatography step in a monoclonal antibody (mAb) manufacturing process using five different methods to introduce the virus to the column. Our data show that whether the virus or the mAbs were introduced in concentrated peaks, or as a homogeneous batch, the clearance of mouse minute virus was similar. This study introduces an alternative way to evaluate viral clearance in a continuous process and demonstrates the robustness of anion exchange chromatography unit operating in continuous processing.  相似文献   

12.
Affordability of biopharmaceuticals continues to be a challenge, particularly in developing economies. This has fuelled advancements in manufacturing that can offer higher productivity and better economics without sacrificing product quality in the form of an integrated continuous manufacturing platform. While platform processes for monoclonal antibodies have existed for more than a decade, development of an integrated continuous manufacturing process for bacterial proteins has received relatively scant attention. In this study, we propose an end‐to‐end integrated continuous downstream process (from inclusion bodies to unformulated drug substance) for a therapeutic protein expressed in Escherichia coli as inclusion body. The final process consisted of a continuous refolding in a coiled flow inverter reactor directly coupled to a three‐column periodic counter‐current chromatography for capture of the product followed by a three‐column con‐current chromatography for polishing. The continuous bioprocessing train was run uninterrupted for 26 h to demonstrate its capability and the resulting output was analyzed for the various critical quality attributes, namely product purity (>99%), high molecular weight impurities (<0.5%), host cell proteins (<100 ppm), and host cell DNA (<10 ppb). All attributes were found to be consistent over the period of operation. The developed assembly offers smaller facility footprint, higher productivity, fewer hold steps, and significantly higher equipment and resin utilization. The complexities of process integration in the context of continuous processing have been highlighted. We hope that the study presented here will promote development of highly efficient, universal, end‐to‐end, fully continuous platforms for manufacturing of biotherapeutics. © 2016 American Institute of Chemical Engineers Biotechnol. Prog., 33:998–1009, 2017  相似文献   

13.
Membrane chromatography possesses numerous advantages such as operation at high flow rates, low back pressure, ease of handling and scale up, which make the membrane adsorber process a viable alternative to conventional packed column chromatography. A purification process for the isolation of human recombinant basic fibroblast growth factor (FGF‐2) based on membrane chromatography was investigated using devices with different flow configurations. In the first process, the FGF‐2 capture step was performed with an axial flow device, while the alternative method achieved direct capture of FGF‐2 from unclarified cell lysate with a tangential flow device. In both processes, FGF‐2 purities exceeded 82% and the purified cytokine displayed high biological activity. Binding capacity (BC) from fermentation broth of the axial flow device was 28 mg/mL. This was 50% higher than the BC obtained with the tangential flow device under particle‐free supernatant conditions (18 mg/mL) and 150% higher compared to the BC achieved with unclarified cell lysate (11 mg/mL). While membrane chromatography in tangential flow mode omits clarification and thus reduces the number of stages in the downstream process, it displays lower peak resolution and leads to a lower overall process yield.  相似文献   

14.
Viral contamination is an inherent risk during the manufacture of biopharmaceuticals. As such, biopharmaceutical companies must demonstrate the viral clearance efficacy of their downstream process steps prior to clinical trials and commercial approval. This is accomplished through expensive and logistically challenging spiking studies, which utilize live mammalian viruses. These hurdles deter companies from analyzing viral clearance during process development and characterization. We utilized a noninfectious minute virus of mice-mock virus particle (MVM-MVP) as a surrogate spiking agent during small scale viral filtration (VF) and anion exchange chromatography (AEX) studies. For VF experiments, in-process mAb material was spiked and processed through Asahi Kasei P15, P20, P35, and BioEX nanofilters. Across each filter type, flux decay profiles and log reduction values (LRVs) were nearly identical for either particle. For AEX experiments, loads were conditioned with various amounts of sodium chloride (9, 20, 23, and 41 mS/cm), spiked with either particle and processed through a Q-SFF packed column. LRV results met our expectations of predicting MVM removal.  相似文献   

15.
Continuous bioprocessing holds the potential to improve product consistency, accelerate productivity, and lower cost of production. However, switching a bioprocess from traditional batch to continuous mode requires surmounting business and regulatory challenges. A key regulatory requirement for all biopharmaceuticals is virus safety, which is assured through a combination of testing and virus clearance through purification unit operations. For continuous processing, unit operations such as capture chromatography have aspects that could be impacted by a change to continuous multicolumn operation, for example, do they clear viruses as well as a traditional batch single column. In this study we evaluate how modifying chromatographic parameters including the linear velocity and resin capacity utilization could impact virus clearance in the context of moving from a single column to multicolumn operation. A Design of Experiment (DoE) approach was taken with two model monoclonal antibodies (mAbs) and two bacteriophages used as mammalian virus surrogates. The DoE enabled the identification of best and worst-case scenario for virus clearance overall. Using these best and worst-case conditions, virus clearance was tested in single column and multicolumn modes and found to be similar as measured by Log Reduction Values (LRV). The parameters identified as impactful for viral clearance in single column mode were predictive of multicolumn modes. Thus, these results support the hypothesis that the viral clearance capabilities of a multicolumn continuous Protein A system may be evaluated using an appropriately scaled-down single mode column and equipment.  相似文献   

16.
A new integrated continuous biomanufacturing platform for continuous production of antibodies at fixed cell volumes and cell concentrations for extended periods with immediate capture is presented. Upstream antibody production has reached technological maturity, however, the bottleneck for continuous biomanufacturing remains the efficient and cost-effective capture of therapeutic antibodies in an initial chromatography step. In this study, the first successful attempt at using one-column continuous chromatography (OCC) for the continuous capture of therapeutic antibodies produced through alternating tangential flow perfusion is presented. By performing upstream media optimizations, the upstream perfusion rate was reduced to one vessel volume per day (vv/d), increasing antibody titer and reducing the volume of perfusate. In addition, process improvements were performed to increase productivity by 80% over previously reported values. In addition, a real-time method for evaluating column performance to make column switching decisions was developed. This improved productivity coupled with the use of a single-column improved process monitoring and control in OCC compared to multi-column systems. This approach is the first report on using a single column for the implementation of an integrated continuous biomanufacturing platform and offers a cost-effective and flexible platform process for the manufacture of therapeutic proteins.  相似文献   

17.
An efficient and consistent method of monoclonal antibody (mAb) purification can improve process productivity and product consistency. Although protein A chromatography removes most host‐cell proteins (HCPs), mAb aggregates and the remaining HCPs are challenging to remove in a typical bind‐and‐elute cation‐exchange chromatography (CEX) polishing step. A variant of the bind‐and‐elute mode is the displacement mode, which allows strongly binding impurities to be preferentially retained and significantly improves resin utilization. Improved resin utilization renders displacement chromatography particularly suitable in continuous chromatography operations. In this study we demonstrate and exploit sample displacement between a mAb and impurities present at low prevalence (0.002%–1.4%) using different multicolumn designs and recycling. Aggregate displacement depends on the residence time, sample concentration, and solution environment, the latter by enhancing the differences between the binding affinities of the product and the impurities. Displacement among the mAb and low‐prevalence HCPs resulted in an effectively bimodal‐like distribution of HCPs along the length of a multi‐column system, with the mAb separating the relatively more basic group of HCPs from those that are more acidic. Our findings demonstrate that displacement of low‐prevalence impurities along multiple CEX columns allows for selective separation of mAb aggregates and HCPs that persist through protein A chromatography.  相似文献   

18.
Downstream processing of mAb charge variants is difficult owing to their similar molecular structures and surface charge properties. This study aimed to apply a novel twin‐column continuous chromatography (called N‐rich mode) to separate and enrich acidic variants of an IgG1 mAb. Besides, a comparison study with traditional scaled‐up batch‐mode cation exchange (CEX) chromatography was conducted. For the N‐rich process, two 3.93 mL columns were used, and the buffer system, flow rate and elution gradient slope were optimized. The results showed that 1.33 mg acidic variants with nearly 100% purity could be attained after a 22‐cycle accumulation. The yield was 86.21% with the productivity of 7.82 mg/L/h. On the other hand, for the batch CEX process, 4.15 mL column was first used to optimize the separation conditions, and then a scaled‐up column of 88.20 mL was used to separate 1.19 mg acidic variants with the purity of nearly 100%. The yield was 59.18% with the productivity of 7.78 mg/L/h. By comparing between the N‐rich and scaled‐up CEX processes, the results indicated that the N‐rich method displays a remarkable advantage on the product yield, i.e. 1.46‐fold increment without the loss of productivity and purity. Generally, twin‐column N‐rich continuous chromatography displays a high potential to enrich minor compounds with a higher yield, more flexibility and lower resin cost.  相似文献   

19.
The clearance of host cell proteins (HCPs) is of crucial importance in biomanufacturing, given their diversity in composition, structure, abundance, and occasional structural homology with the product. The current approach to HCP clearance in the manufacturing of monoclonal antibodies (mAbs) relies on product capture with Protein A followed by removal of residual HCPs in flow-through mode using ion exchange or mixed-mode chromatography. Recent studies have highlighted the presence of “problematic HCP” species, which are either difficult to remove (Group I), can degrade the mAb product (Group II), or trigger immunogenic reactions (Group III). To improve the clearance of these species, we developed a family of synthetic peptides that target HCPs and exhibit low binding to IgG product. In this study, these peptides were conjugated onto chromatographic resins and evaluated in terms of HCP clearance and mAb yield, using an industrial mAb-producing CHO harvest as model supernatant. To gather detailed knowledge on the binding of individual HCPs, the unbound fractions were subjected to shotgun proteomic analysis by mass spectrometry. It was found that these peptide ligands exhibit superior HCP binding capability compared to those of the benchmark commercial resins commonly used in mAb purification. In addition, some peptide-based resins resulted in much lower losses of product yield compared to these commercial supports. The proteomic analysis showed effective capture of many “problematic HCPs” by the peptide ligands, especially some that are weakly bound by commercial media. Collectively, these results indicate that these peptides show great promise toward the development of next-generation adsorbents for safer and cost-effective manufacturing of biologics.  相似文献   

20.
The preparation of plasmid DNA at large scale constitutes a pressing problem in bioseparation. This paper describes a first investigation of displacement chromatography as a means to separate plasmid DNA (4.7 kb) from E. coli lipopolysaccharides and protein (holo transferrin), respectively. Displacement chromatography has advantages in this regard, since the substance mixture is resolved into rectangular zones of the individual components rather than into peaks. Thus a higher total concentration can be maintained in the pooled product fractions. Hydroxyapatite (type I and II) and anion exchange stationary phases were included in the experiments. In addition to a conventional anion exchange column packed with porous particles, the recently introduced continuous bed UNOTM anion exchange column was investigated. No DNA purification was possible with either hydroxyapatite material. Conventional particle based columns in general were not suited to the separation of any two substances varying considerably in molecular mass, e.g. plasmid DNA and standard protein. Presumably, the direct competition for the binding sites, which is essential in displacement chromatography, was restricted by the size dependency of the accessible stationary phase surface area in this case. Better results were obtained with the continuous bed column, in which the adsorptive surface coincides with the walls of the flow through pores. As a result the accessible surface does not vary as much with the size of the interacting molecules as for the conventional stationary phase materials. Sharper transitions were also observed between substance zones recovered from the UNOTM column. The steric mass action model was used to aid method development in case of the anion exchange approach. While further research in obviously necessary, displacement chromatography on continuous bed columns has been shown to be capable of separating plasmid DNA from typical impurities. This revised version was published online in July 2006 with corrections to the Cover Date.  相似文献   