首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 400 毫秒
1.

Background

Organic electrochemical transistors (OECT) have been used as various types of biosensors with very high sensitivity. The OECTs show advantages of easy fabrication, low operational voltage, excellent flexibility and biocompatibility.

Methods

OECT arrays based on poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) were fabricated in poly(ethylene glycol) (PEG) microwells by physical delamination.

Results

The OECTs show fast response time, stable channel current and excellent transistor characteristics. The PEG microwells can be used to trap cells on top of the OECTs, which will be important for the application of the OECT arrays as cell-based biosensors.

General significance

This technique provides a feasible way for high-throughput cell analysis based on transistor arrays. This article is part of a Special Issue entitled Organic Bioelectronics—Novel Applications in Biomedicine.  相似文献   

2.
Organic electrochemical transistors (OECTs) based on poly(3,4-ethylenedioxythiophene):poly(styrene sulfonic acid) (PEDOT:PSS) with different gate electrodes, including graphite, Au and Pt electrode, etc., have been used as dopamine sensor for the first time. The sensitivity of the OECT to dopamine depends on its gate electrode and operation voltage. We find that the device with a Pt gate electrode characterized at the gate voltage of 0.6 V shows the highest sensitivity. The detection limit of the device to dopamine is lower than 5 nM, which is one order of magnitude better than a conventional electrochemical measurement with the same Pt electrode. It is expected that OECT is a good candidate for low cost and highly sensitive biosensor for the detection of dopamine.  相似文献   

3.
Poly(3,4‐ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) is widely used as hole injection/extraction material in organic optoelectronics. However, there still exist drawbacks for PEDOT:PSS such as low work function (WF), poor structural and electrical homogeneity. To solve these problems, methylnaphthalene sulfonate formaldehyde condensate (MNSF) is applied, which has excellent dispersion property, branched chemical structure, and low cost, as dispersant and dopant instead of linear PSS to prepare PEDOT:MNSF. The hole injection/extraction capability of PEDOT:MNSF is systematically studied in organic optoelectronic devices. PEDOT:MNSF‐1:6 exhibits unexpected high device performance with a maxima current efficiency of 33.4 cd A?1 in blue phosphorescent organic light‐emitting diode and a power conversion efficiency of 13.1% in CH3NH3PbIx Cl3?x ‐based inverted perovskite solar cell, respectively. Compared with PEDOT:PSS, the relatively higher efficiency of PEDOT:MNSF‐1:6 is attributed mainly to its higher WF of 5.29 eV, structural and electrical homogeneity. Our research displays a promising future of MNSF as a cheap and widely available alternative of PSS. Moreover, a clear map is provided for the design of dopant for PEDOT considering the structure of dopant.  相似文献   

4.
Zhao H  Ju H 《Analytical biochemistry》2006,350(1):138-144
A bilayer of the polyelectrolytes poly(dimethyldiallylammonium chloride) (PDDA) and poly(sodium 4-styrenesulfonate) (PSS) was formed on a 3-mercapto-1-propanesulfonic-acid-modified Au electrode. Subsequently, multiwall carbon nanotubes (MWCNTs) wrapped by positively charged PDDA were assembled layer-by-layer with negatively charged glucose oxidase (GOx) onto the PSS-terminated bilayer. Electrochemical impedance spectroscopy and atomic force microscopy were adopted to monitor the regular growth of the PDDA-MWCNTs/GOx bilayers. Using GOx as a model enzyme, the assembled multilayer membranes showed some striking features such as the adsorbed form of GOx on individual MWCNT, uniformity, good stability, and electrocatalytic activity toward oxygen reduction. Based on the consumption of dissolved oxygen during the oxidation process of glucose catalyzed by the immobilized GOx, a sensitive amperometric biosensor was developed for the detection of glucose up to 5.0 mM with a detection limit of 58 microM. The sensitivity increased with increasing sensing layers up to five bilayers. Ascorbic acid and uric acid did not cause any interference due to the use of a low operating potential. The present method showed high reproducibility for the fabrication of carbon-nanotubes-based amperometric biosensors.  相似文献   

5.
Poly(3,4‐ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) has been is applied as hole transport material in organic electronic devices for more than 20 years. However, the redundant sulfonic acid group of PEDOT:PSS has often been overlooked. Herein, PEDOT:PSS‐DA is prepared via a facile doping of PEDOT:PSS with dopamine hydrochloride (DA·HCl) which reacts with the redundant sulfonic acid of PSS. The PEDOT:PSS‐DA film exhibits enhanced work function and conductivity compared to those of PEDOT:PSS. PEDOT:PSS‐DA‐based devices show a power conversion efficiency of 16.55% which is the highest in organic solar cells (OSCs) with (poly[(2,6‐(4,8‐bis(5‐(2‐ethylhexyl)‐4‐fluorothiophen‐2‐yl)benzo[1,2‐b:4,5‐b′]dithio‐phene))‐co‐(1,3‐di(5‐thiophene‐2‐yl)‐5,7‐bis(2‐ethylhexyl)‐benzo[1,2‐c:4,5‐c′]dithiophene‐4,8‐dione))] (PM6):(2,2′‐((2Z,2′Z)‐((12,13‐bis(2‐ethylhexyl)‐3,9‐diundecyl‐12,13‐dihydro‐[1,2,5]thiadiazolo[3,4‐e]thieno[2′′,3′:4′,5′]thieno[2′,3′:4,5]pyrrolo[3,2‐g]thieno[2′,3′:4,5]thieno[3,2‐b]indole‐2,10‐diyl)bis(methanylylidene))bis(5,6‐difluoro‐3‐oxo‐2,3‐dihydro‐1H‐indene‐2,1‐diylidene))dimalononitrile) (Y6) as the active layer. Furthermore, PEDOT:PSS‐DA also exhibits enhanced performance in three other donor/acceptor systems, exhibiting high compatibility in OSCs. This work demonstrates that doping PEDOT:PSS with various amino derivatives is a potentially efficient strategy to enhance the performance of PEDOT:PSS in organic electronic devices.  相似文献   

6.
Highly efficient organic–inorganic hybrid solar cells of Si‐poly(3,4‐ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) have been demonstrated by simultaneous structural, electrical, and interfacial engineering with low processing temperature. Si substrate has been sculpted into hierarchical structure to reduce light reflection loss and increase interfacial junction area at the same time. Regarding the electrical optimization, highly conductive organic PEDOT:PSS layer has been formulated with low sheet resistance. It is argued that the sheet resistance, rather than conductivity, is the primary parameter for the high efficiency hybrid cells, which leads to the optimization of thickness, i.e., thick enough to have low sheet resistance but transparent enough to pass the incident sunlight. Finally, siloxane oligomers have been inserted into top/bottom interfaces by contact‐printing at room ambient, which suppresses carrier recombination at interfaces and reduces contact resistance at bottom electrode. Contrary to high‐temperature doping (for the formation of front surface or back surface fields), wet solution processes or vacuum‐based deposition, the contact‐printing can be done at room ambient to reduce carrier recombination at the interfaces. The high efficiency obtained with low processing temperature can make this type of cells be a possible candidate for post‐Si photovoltaics.  相似文献   

7.
Gold nanoparticles stabilized by amino-terminated ionic liquid (Au-IL) have been in situ noncovalently deposited on poly(sodium 4-styrene-sulfonate) (PSS)-functionalized multiwalled carbon nanotubes (MWCNTs) to form a MWCNTs/PSS/Au-IL nanocomposite. PSS can interact with MWCNTs through hydrophobic interaction. Amino-terminated ionic liquid was applied to reduce aqueous HAuCl(4), and the resulting gold nanoparticles were attached to the PSS-functionalized MWCNTs simultaneously. Most gold nanoparticles dispersed well on the functionalized MWCNTs. Transmission electron microscopy, Raman and X-ray photoelectron spectroscopy were used to confirm the composition and structure of the nanocomposites. The resulting MWCNTs/PSS/Au-IL composite exhibits good electrocatalysis toward oxygen and hydrogen peroxide reduction. And good biocompatibility with glucose oxidase was also demonstrated due to its good biocatalysis toward glucose substrate, which offered a friendly environment for the immobilization of biomolecules. Such bionanocomposite provides us potential applications in fabrication of biosensors. The resulting biosensor exhibits good response to glucose with a low detection limit 25 microM. It also has excellent reproducibility, satisfied operational stability and good storage stability.  相似文献   

8.
A prerequisite for exploiting sensing devices based on semiconductor nanowires is ultra-sensitive and selective direct electrical detection of biological and chemical species. Here, we constructed a transducer based on copolymer of poly(3,4,-ethylenedioxythiophene) (PEDOT) and carboxylic group functionalised PEDOT single nanowire in between gold electrodes, followed by covalent attachment of amino-modified probe oligonucleotide. The target ODNs specific to Homo sapiens Breast and ovarian cancer cells were detected at femtomolar concentration and incorporation of negative controls (non-complementary ODN) were clearly discriminated by the sensor. The ex situ measurements were performed by using two terminal device setup and the changes in the interface of the nanowire associated with the association or dissociation of ODNs were measured as change in resistance. In addition, in situ measurements were performed by utilizing scanning ion conductance microscopy to measure the change in resistance of probe modified nanowire upon addition of different concentration of target ODNs in presence of relevant buffer. The constructed, nano sensor showed highly sensitive concentration dependent resistance change.  相似文献   

9.
Properties of hole transporting layers (HTLs) and back electrode are very critical to the stability of inverted bulk heterojunction organic photovoltaic (OPV) modules. Here, various deposition methods for back electrodes and materials of HTLs are examined by applying to inverted organic solar cells with a structure of indium tin oxide/ZnO/photoactive layer/poly(3,4‐ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS)/Ag. The experiment is performed on encapsulated modules with flexible barrier films under accelerated conditions. The OPV modules with screen‐printed Ag electrodes are shown to be electrically unstable with a reduction of the current density under damp heat condition at 85 °C/85% RH. Optical images for the active layer/PEDOT:PSS interface reveal that a reaction between the solvent from the Ag electrode and the underlying layers is the major cause for the degradation. In comparison with materials of the HTLs, the PEDOT:PSS layer shows low stability compared to the MoO3 layer under the accelerated conditions. Unusual chemical changes in the PEDOT:PSS film are observed through X‐ray photoelectron spectroscopy and this is further addressed by correlating the stability of the OPV devices.  相似文献   

10.
A biosensor platform based on polyamic acid (PAA) is reported for oriented immobilization of biomolecules. PAA, a functionalized conducting polymer substrate that provides electrochemical detection and control of biospecific binding, was used to covalently attach biomolecules, resulting in a significant improvement in the detection sensitivity. The biosensor sensing elements comprise a layer of PAA antibody (or antigen) composite self-assembled onto gold (Au) electrode via N-hydroxysuccinimide (NHS) and 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC) linking. The modified PAA was characterized by Fourier transform infrared (FTIR), (1)H nuclear magnetic resonance (NMR), and electrochemical techniques. Cyclic voltammetry and impedance spectroscopy experiments conducted on electrodeposited PAA on Au electrode using ferricyanide produced a measurable decrease in the diffusion coefficient compared with the bare electrode, indicating some retardation of electron transfer within the bulk material of the PAA. Thereafter, the modified PAA surface was used to immobilize antibodies and then to detect inducible nitric oxide synthase and mouse immunoglobulin G (IgG) using enzyme-linked immunosorbent assay (ELISA), surface plasmon resonance (SPR), and amperometric techniques. ELISA results indicated a significant amplified signal by the modified PAA, whereas the SPR and amperometric biosensors produced significant responses as the concentration of the antigen was increased. Detection limits of 3.1×10(-3)ng/ml and 2.7×10(-1)ng/ml were obtained for SPR and amperometric biosensors, respectively.  相似文献   

11.
Barriers to charge transfer at electrode‐semiconductor contacts are ubiquitous and limit the applicability of organic semiconductors in electronic devices. Molecular or ionic doping near contacts can alleviate charge injection or extraction problems by enabling charge tunneling through contact barriers, but the soft nature of organic materials allows for small molecule dopants to diffuse and migrate, degrading the performance of the device and limiting effective interfacial doping. Here, it is demonstrated that contact doping in organic electronics is possible through ionic polymer dopants, which resist diffusion or migration due to their large size. Sub‐monolayer deposition of non‐conjugated strong polyelectrolytes, e.g., sulfonated poly(sulfone)s, at the anode‐semiconductor interface of organic photovoltaics enables efficient hole extraction at the anode. The performance of contact‐doped organic photo­voltaics nearly matches the performance of devices composed of traditional hole transport layers such as poly(3,4‐ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS). The degree of sulfonation of the dopant polymer and the thickness of the ionic dopant layer is shown to be critical for optimizing doping and the efficiency of the device.  相似文献   

12.
Polyaniline (PAni) has been used frequently for the construction of biosensors. However, a prime limitation is its instability at basic or neutral pH because of the loss of its electrochemical activity and conductivity. In this study, three available sulfonated polyanions: Nafion, poly(vinyl sulfonate) (PVS), and poly(styrene sulfonate) (PSS) serving as the counterion and providing an acidic microenvironment to stabilize PAni, are used to fabricate a sensor for ammonium ion detection. Nafion used to be a common ion-sensitive membrane due to its high proton conductivity. However, its high cost and limited solubility has constrained its uses. PVS and PSS are water-soluble polymers, easily incorporating with PAni to form the composites. Surface analysis by electron spectroscopy for chemical analysis (ESCA) and scanning electron microscope (SEM), and the electrochromic property for the PAni composites provided the convenient tools to characterize the electrode fabrication. On the aspect of sensing the ammonium ions, the modified electrodes exhibited electroactivity of PAni in ammonium ion detection and also showed the linear dependence of reduction current on the ammonium ion concentration. The pH effect on the sensing response was also evaluated and found insignificant to the response (ranging from pH 6.9-7.6). For increasing the stability of the electrodes, the diazo-resin (DAR) was introduced to the coat on the outmost layer and then cured by UV irradiation, giving the covalent network between the layers of polyelectrolytes. The PSS-doped PAni electrode was found to perform detection sensitivity in the linear range of 0-100mM of ammonium ion concentration.  相似文献   

13.
Abstract

Early detection of tuberculosis (TB) reduces the interval between infection and the beginning of treatment. However, commercially available tests cannot discriminate between BCG-vaccinated healthy persons and patients. Also, they are not suitable to be used for immunocompromised persons. In recent years, biosensors have attracted great attention due to their simple utility, accessibility, and real-time outputs. These sensors are increasingly being considered as pioneering tools for point-of-care diagnostics in communities with a high burden of TB and limited accessibility to reference laboratories. Among other types of biosensors, the electrochemical sensors have the advantages of low-cost operation, fast processing, simultaneous multi-analyte analyzing, operating with turbid samples, comparable sensitivity and readily available miniaturization. Electrochemical biosensors are sub-divided into several categories including: amperometric, impedimetric, potentiometric, and conductometric biosensors. The biorecognition element in electrochemical biosensors is usually based on antibodies (immunosensors), DNAs or PNAs (genosensors), and aptamers (aptasensors). In either case, whether an interaction of the antigen–antibody/aptamer or the hybridization of probe with target mycobacterial DNA is detected, a change in the electrical current occurs that is recorded and displayed as a plot. Therefore, impedimetric-based methods evaluate resistance to electron transfer toward an electrode by a Nyquist plot and amperometric/voltammetric-based methods weigh the electrical current by means of cyclic voltammetry, square wave voltammetry, and differential pulse voltammetry. Electrochemical biosensors provide a promising scope for the new era of diagnostics. As a consequence, they can improve detection of Mycobacterium tuberculosis traces even in attomolar scales.  相似文献   

14.
Microscopic characterization of charge carriers in solar cells is useful for high‐performance cell fabrication because the formation and accumulation of charges in cells greatly affect the device performance. Electron spin resonance (ESR) is suitable for such characterization because it can directly observe charge carriers with spins in these cells. In this work, the ESR method is applied to organic thin‐film solar cells to investigate charge formation in such devices. Heterojunction cells of indium tin oxide (ITO)/poly(3,4‐ethylenedioxythiophene):poly(4‐styrenesulfonate) (PEDOT:PSS)/pentacene/C60/bathocuproine (BCP)/Al are investigated. Clear ESR signals are observed by inserting a typical PEDOT:PSS hole buffer layer. From analysis of the dependence of the ESR characteristics on the external magnetic field direction, the bias voltage, and the duration of solar‐simulated irradiation, the charges (mobile holes) in pentacene layers are successfully identified and it can be deduced that these holes are formed at the PEDOT:PSS/pentacene interface during device fabrication. This ESR analysis provides useful knowledge for understanding device operation and improving device performance at the microscopic level.  相似文献   

15.
A new dicarbazole derivative functionalised by an N-hydroxysuccinimide group has been synthesised and electrochemically characterised. Upon oxidative electropolymerisation of this monomer in organic electrolytes, electroactive poly(dicarbazole) films were formed on platinum electrodes. The subsequent chemical grafting of tyrosinase on the poly(dicarbazole) film was easily performed by immersion in an enzymatic aqueous solution. The amperometric response of the resulting biosensors to catechol has been studied at -0.2 V vs. saturated calomel electrode (SCE). Since the reduction of quinone generates radicals which may induce electrode fouling, thionine, a phenothiazine dye, was covalently bound to the poly(dicarbazole) backbone as it mediates the reduction of quinoid products and therefore induces an enhancement of the performance of the tyrosinase-based biosensor.  相似文献   

16.

Background

Organic electrochemical transistors (OECTs), which are becoming more and more promising devices for applications in bioelectronics and nanomedicine, are proposed here as ideally suitable for sensing and real time monitoring of liposome-based structures. This is quite relevant since, currently, the techniques used to investigate liposomal structures, their stability in different environments as well as drug loading and delivery mechanisms, operate basically off-line and/or with pre-prepared sampling.

Methods

OECTs, based on the PEDOT:PSS conductive polymer, have been employed as sensors of liposome-based nanoparticles in electrolyte solutions to assess sensitivity and monitoring capabilities based on ion-to-electron amplified transduction.

Results

We demonstrate that OECTs are very efficient, reliable and sensitive devices for detecting liposome-based nanoparticles on a wide dynamic range down to 10− 5 mg/ml (with a lowest detection limit, assessed in real-time monitoring, of 10− 7 mg/ml), thus matching the needs of typical drug loading/drug delivery conditions. They are hence particularly well suited for real-time monitoring of liposomes in solution. Furthermore, OECTs are shown to sense and discriminate successive injection of different liposomes, so that they could be good candidates in quality-control assays or in the pharmaceutical industry.

General significance

Drug loading and delivery by liposome-based structures is a fast growing and very promising field that will strongly benefit from real-time, highly sensitive and low cost monitoring of their dynamics in different pharma and biomedical environments, with a particular reference to the pharmaceutical and production processes, where a major issue is monitoring and measuring the formation and concentration of liposomes and the relative drug load. The demonstrated ability to sense and monitor complex bio-structures, such as liposomes, paves the way for very promising developments in biosensing and nanomedicine. This article is part of a Special Issue entitled Organic Bioelectronics—Novel Applications in Biomedicine.  相似文献   

17.
In an effort to create a paintable/printable thermoelectric material, comprised exclusively of organic components, polyaniline (PANi), graphene, and double‐walled nanotube (DWNT) are alternately deposited from aqueous solutions using the layer‐by‐layer assembly technique. Graphene and DWNT are stabilized with an intrinsically conductive polymer, poly(3,4‐ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS). An 80 quadlayer thin film (≈1 μm thick), comprised of a PANi/graphene‐PEDOT:PSS/PANi/DWNT‐PEDOT:PSS repeating sequence, exhibits unprecedented electrical conductivity (σ ≈ 1.9 × 105 S m?1) and Seebeck coefficient (S ≈ 120 μV K?1) for a completely organic material. These two values yield a thermoelectric power factor (PF = S 2 σ ?1) of 2710 μW m?1 K?2, which is the highest value ever reported for a completely organic material and among the highest for any material measured at room temperature. These outstanding properties are attributed to the highly ordered structure in the multilayer assembly. This water‐based thermoelectric nanocomposite is competitive with the best inorganic semiconductors (e.g., bismuth telluride) at room temperature and can be applied as a coating to any flexible surface (e.g., fibers in clothing). For the first time, there is a real opportunity to harness waste heat from unconventional sources, such as body heat, to power devices in an environmentally‐friendly way.  相似文献   

18.

Background

An exciting direction in nanomedicine would be to analyze how living cells respond to conducting polymers. Their application for tissue regeneration may advance the performance of drug eluting stents by addressing the delayed stent re-endothelialization and late stent thrombosis.

Methods

The suitability of poly (3, 4-ethylenedioxythiophene) (PEDOT) thin films for stents to promote cell adhesion and proliferation is tested in correlation with doping and physicochemical properties. PEDOT doped either with poly (styrenesulfonate) (PSS) or tosylate anion (TOS) was used for films' fabrication by spin coating and vapor phase polymerization respectively. PEGylation of PEDOT: TOS for reduced immunogenicity and biofunctionalization of PEDOT: PSS with RGD peptides for induced cell proliferation was further applied. Atomic Force Microscopy and Spectroscopic Ellipsometry were implemented for nanotopographical, structural, optical and conductivity measurements in parallel with wettability and protein adsorption studies. Direct and extract testing of cell viability and proliferation of L929 fibroblasts on PEDOT samples by MTT assay in line with SEM studies follow.

Results

All PEDOT thin films are cytocompatible and promote human serum albumin adsorption. PEDOT:TOS films were found superior regarding cell adhesion as compared to controls. Their nanotopography and hydrophilicity are significant factors that influence cytocompatibility. PEGylation of PEDOT:TOS increases their conductivity and hydrophilicity with similar results on cell viability with bare PEDOT:TOS. The biofunctionalized PEDOT:PSS thin films show enhanced cell proliferation.

Conclusions

The application of PEDOT polymers has evolved as a new perspective to advance stents.

General significance

In this work, nanomedicine involving nanotools and novel nanomaterials merges with bioelectronics to stimulate tissue regeneration for cardiovascular implants. This article is part of a Special Issue entitled Organic Bioelectronics — Novel Applications in Biomedicine.  相似文献   

19.
A solution‐processed neutral hole transport layer is developed by in situ formation of MoO3 in aqueous PEDOT:PSS dispersion (MoO3‐PEDOT:PSS). This MoO3‐PEDOT:PSS composite film takes advantage of both the highly conductive PEDOT:PSS and the ambient conditions stability of MoO3; consequently it possesses a smooth surface and considerably reduced hygroscopicity. The resulting bulk heterojunction polymer solar cells (BHJ PSC) based on poly[2,3‐bis‐(3‐octyloxyphenyl)quinoxaline‐5,8‐diyl‐alt‐thiophene‐2,5‐diyl] (TQ1):[6,6]‐phenyl‐C71‐butyric acid methyl ester (PC70BM) blends using MoO3‐PEDOT:PSS composite film as hole transport layer (HTL) show considerable improvement in power conversion efficiency (PCE), from 5.5% to 6.4%, compared with the reference pristine PEDOT:PSS‐based device. More importantly, the device with MoO3‐PEDOT:PSS HTL shows considerably improved stability, with the PCE remaining at 80% of its original value when stored in ambient air in the dark for 10 days. In comparison, the reference solar cell with PEDOT:PSS layer shows complete failure within 10 days. This MoO3‐PEDOT:PSS implies the potential for low‐cost roll‐to‐roll fabrication of high‐efficiency polymer solar cells with long‐term stability at ambient conditions.  相似文献   

20.
The prototype of an amperometric glucose biosensor was realized by thermal inkjet printing using biological and electronic water-based inks, containing a glucose oxidase (GOD) from Aspergillus niger and the conducting polymer blend poly(3,4-ethylenedioxythiophene/polystyrene sulfonic acid) (PEDOT/PSS), respectively. The biosensor was fabricated microdepositing PEDOT/PSS and GOD, in sequence, on ITO-glass, by a commercial inkjet printer, with the help of a commercial software. High density microdots matrices were so-realized, with a calculated resolution of about 221 x 221 dpi (dot per inch). By means of a rapid and easy assay it was demonstrated that no activity loss occurred upon the printing of GOD, despite of the use of a thermal printhead. The device was encapsulated in a semipermeable membrane of cellulose acetate, applied by dip-coating, in order to prevent dissolution of the enzyme and/or PEDOT/PSS in water. The preliminary response of the electrode was measured in an aqueous glucose solution in the presence of ferrocenemethanol (FeMeOH) as a mediator, and resulted linear up to 60 mM in glucose. The best sensitivity value achieved was 6.43 microAM(-1) cm(-2) (447 nAM(-1) U(-1) cm(-2)). The characteristics of the device, and the possible performance improvements have been analyzed and discussed. The reported findings indicate that inkjet printing could be a viable instrument for the easy construction of a working biosensor via direct digital design using biological and conductive polymer based inks. Such an approach may be seen as an example of "biopolytronics".  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号