首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The application of 4-iodophenol as a signal enhancer for luminol-based immunodot and Western blotting assays was investigated. Immunodetection of biotin-bovine serum albumin (BSA) using a rat anti-biotin antibody for immunodot binding and goat anti-biotin peroxidase conjugate for Western blotting assays was employed to demonstrate the signal enhancement attainable with 4-iodophenol. The addition of 4-iodophenol at a final working concentration of 52.2 microM to a light-emitting substrate, luminol, resulted in 3-fold and 10-fold signal enhancements for Western blotting and immunodot binding detection of biotin-BSA, respectively.  相似文献   

2.
A variety of luminol-based substrates and either an autoradiographic film or a charge-coupled device (CCD) imaging system were used for chemiluminescence detection of c-type cytochromes. The Pierce Femto peroxidase substrate was at least 10 times more sensitive when using film than the highly cited 3,3('),5,5(')-tetramethylbenzidine (benzidine derivative) staining method and 50 times more sensitive when using a CCD imaging system. Film or CCD imaging result in highly sensitive and quantitative signals. The quantitative detection of c-type cytochromes from single colonies or from less than 1ml of a bacterial culture is possible.  相似文献   

3.
Western blotting is a powerful and widely used method, but limitations in detection sensitivity and specificity, and dependence upon high quality antibodies to detect targeted proteins, are hurdles to overcome. The in situ proximity ligation assay, based on dual antibody recognition and powerful localized signal amplification, offers increased detection sensitivity and specificity, along with an ability to identify complex targets such as phosphorylated or interacting proteins. Here we have applied the in situ proximity ligation assay mechanism in Western blotting. This combination allowed the use of isothermal rolling circle amplification of DNA molecules formed in target-specific ligation reaction, for 16-fold or greater increase in detection sensitivity. The increased specificity because of dual antibody recognition ensured highly selective assays, detecting the specific band when combinations of two cross-reactive antitubulin antibodies were used (i.e. both producing distinct nonspecific bands in traditional Western blotting). We also demonstrated detection of phosphorylated platelet-derived growth factor receptor β by proximity ligation with one antibody directed against the receptor and another directed against the phosphorylated tyrosine residue. This avoided the need for stripping and re-probing the membrane or aligning two separate traditional blots. We demonstrate that the high-performance in situ proximity ligation-based Western blotting described herein is compatible with detection via enhanced chemiluminescence and fluorescence detection systems, and can thus be readily employed in any laboratory.  相似文献   

4.
The adaptation and improvement of serological assays for the detection of plant viruses has steadily developed. A filter paper immunobinding assay, Western blotting and the double sandwich ELISA were compared for the detection and quantification of wheat streak mosaic virus. ELISA was a more quantitative assay, but the filter paper immunobinding assay and Western blotting were more conservative of antiserum when only a few assays were required and could be run in a shorter period of time.  相似文献   

5.
A streamlined protocol is described that allows high sensitivity antigen detection by Western blotting in a single day. The choice of membrane blotting matrix, as well as blocking reagents, has been optimized in order to allow rapid development of the blot with chemiluminescent reagents. The entire process, from gel to blot to a permanent, hard copy image on x-ray film, can be accomplished within six hours.  相似文献   

6.
Improved chemiluminescent western blotting procedure.   总被引:3,自引:0,他引:3  
A chemiluminescent Western blotting procedure and its application in assays for human transferrin and human immunodeficiency virus-I antibodies are described. The procedure is based on a chemiluminescent substrate, adamantyl 1,2-dioxetane aryl phosphate and alkaline phosphatase-labeled detection antibodies. Different membranes (polyvinylidene fluoride, nitrocellulose, nylon) and a proprietary membrane treatment agent (Nitro-Block) have been studied. This sensitive blotting procedure utilizing AMPPD, a polyclonal rabbit anti-transferrin:goat anti-rabbit IgG-alkaline phosphatase detection complex, and a PVDF membrane blocked with Nitro-Block permits the detection of 125 pg (1.6 fmol) of human transferrin. A novel 1,2-dioxetane substrate, CSPD, has also been evaluated.  相似文献   

7.
Simple Western is a new technology that allows for the separation, blotting, and detection of proteins similar to a traditional Western except in a capillary format. Traditionally, identity assays for biological products are performed using either an enzyme-linked immunosorbent assay (ELISA) or a manual dot blot Western. Both techniques are usually very tedious, labor-intensive, and complicated for multivalent vaccines, and they can be difficult to transfer to other laboratories. An advantage this capillary Western technique has over the traditional manual dot blot Western method is the speed and the automation of electrophoresis separation, blotting, and detection steps performed in 96 capillaries. This article describes details of the development of an automated identity assay for a 15-valent pneumococcal conjugate vaccine, PCV15–CRM197, using capillary Western technology.  相似文献   

8.
Sensitive fluorescent detection of protein on nylon membranes   总被引:2,自引:0,他引:2  
Detection of antigen immobilized on membranes, as in Western transfers and dot enzyme linked immunosorbent assays (ELISAs), often employ antibody-enzyme conjugates and chemiluminescent or precipitated colored reaction products. Although chemiluminescent markers are sensitive, they are time-consuming because of their required exposure to X-ray film and the presence of background artifacts sometimes limits their use. This report demonstrates that direct fluorescent detection technique using nylon membranes that has higher sensitivity than chemiluminescent methods is easier to perform and has a uniform, low background. An alkaline phosphatase conjugated antibody was compared with antibody conjugated to a fluorescent phycobiliprotein (allophycocyanin) for sensitivity in both Western transfers and dot ELISA assays using mouse IgG as the membrane-bound antigen. Direct fluorescent detection of antigen-antibody complexes on positively charged nylon membrane provided better sensitivity and lower background than similar conditions using enzyme amplification and chemiluminescent detection on either nylon or PVDF membranes. Processing time was reduced by the elimination of steps associated with substrate incubation, washing and X-ray film exposures required for chemiluminescence detection. These data support the view that direct fluorescent detection can represent a significant improvement in assay sensitivity and reduction in time compared with more traditional chemiluminescent detection techniques employed in the conduct of Western transfers and dot ELISA studies.  相似文献   

9.
A chemiluminescent reaction based on the deprotection of a phosphorylated phenyl dioxetane by alkaline phosphatase has recently been described (Schaap, A.P., 1988, J. Biolumin. Chemilumin. 2, 253). Light output is enhanced by intermolecular energy transfer to a micelle-solubilized fluorophore. This system is applied here to the detection of DNA probes on Southern blots. Enzyme solution assays which give an indication of sensitivity show that using this substrate 100 fg (0.7 amol) alkaline phosphatase can be detected on a luminescence plate reader (200 ms reading time). In a model Southern blotting system 180 fg HindIII digested lambda DNA was detected on film with homologous biotinylated DNA and a streptavidin-alkaline phosphatase complex. The single copy genes mos and raf-1, representing targets of 4.2 and 2.4 pg target DNA respectively, have also been detected in Southern-blotted human genomic DNA. A delay in reaching a plateau level of light output which is dependent on pH is observed but signal continues for at least 7 days. Typically, 12-h exposures to X-ray film were performed but once a steady-state light output had been achieved this time could be reduced to 2 h by preflashing film. This detection system represents a sensitive nonradioactive method, which is applicable not only to Southern blots but also to Northern and Western blots and any assay in which alkaline phosphatase is the label.  相似文献   

10.
目的:对抗体进行改进,降低传统蛋白质免疫印迹方法的检出限。方法:在传统蛋白质免疫印迹方法的基础上,将一抗和二抗分别与纳米金和氧化石墨烯结合,以提高其对痕量样本的检测灵敏度,降低检测限。结果:优化后的方法对β-淀粉样蛋白的检测限从原来的432 pg/mL降低至16 pg/mL,为原来的1/27。结论:改进后的蛋白质免疫印迹新方法性能稳定,重复性好,可用于生物样本中痕量被检测物的测定。  相似文献   

11.
12.
Myositis is a common clinical syndrome in advanced stages of AIDS. Trachipleistophora hominis (phylum Microspora) has been detected in several cases of painful, immobilising myositis in AIDS patients. Enzyme linked immunosorbent assays (ELISAs) and Western blotting of protein profiles separated by SDS PAGE were used to determine whether this species could be detected and differentiated by serology. Sixteen microsporidia, including several species known to infect man and species infecting fish, crustaceans and a mosquito, were used as antigen. Each species had a unique profile of SDS PAGE-separated proteins. In Western blots, mouse antiserum, raised to T. hominis and selected for its high ELISA specificity, bound to antigens ranging from less than 25 kDa to greater than 250 kDa with major bands at 39-44 kDa and 98-150 kDa on T. hominis protein profiles. The serum also recognised some high molecular weight antigens in the profiles of Vavraia culicis, Heterosporis anguillarum, and three species of Pleistophora but none in the remaining genera examined. It was concluded that ELISA and Western blotting could be used to detect and differentiate T. hominis in muscle biopsy tissue from patients with myositis. However, sera from T. hominis-infected patients in the terminal stages of AIDS would not be useful for detection of infections because of a sharp decline in antibody level.  相似文献   

13.
An intestinal protozoan parasite, Cryptosporidium parvum, is a major cause of waterborne gastrointestinal disease worldwide. Detection of Cryptosporidium oocysts in potable water is a high priority for the water treatment industry to reduce potential outbreaks among the consumer populace. Anti-Cryptosporidium oocyst polyclonal and monoclonal antibodies were tested as capture and detection reagents for use in a fiber optic biosensor assay for the detection of Cryptosporidium oocysts. Antibodies were validated using enzyme-linked immunosorbent assays, flow cytometry, Western blotting and fluorescent microscopy. Oocysts could be detected at a concentration of 105 oocysts/ml when the polyclonal antibodies were used as the capture and detection reagents. When oocysts were boiled prior to detection, a ten-fold increase in sensitivity was achieved using the polyclonal antibody. Western blotting and immunofluorescence revealed that both the monoclonal and polyclonal antibodies recognize a large (>300 kDa) molecular weight mucin-like antigen present on the surface of the oocyst wall. The polyclonal antibody also reacted with a small (105 kDa) molecular weight antigen that was present in boiled samples of oocysts. Preliminary steps to design an in-line biosensor assay system have shown that oocysts would have to be concentrated from water samples and heat treated to allow detection by a biosensor assay.  相似文献   

14.
旨在建立一种检测口蹄疫病毒非结构蛋白抗体的敏感、特异的ELISA方法。克隆、表达了口蹄疫病毒非结构蛋白3AB基因,原核表达的重组蛋白经亲和层析法纯化及Western blotting鉴定后作为包被抗原,建立检测口蹄疫病毒非结构蛋白抗体的3AB间接ELISA方法,通过与商品化试剂盒3ABC-ELISA的比对试验对其进行评价。结果显示,重组蛋白3AB以包涵体形式表达;能与口蹄疫病毒感染血清发生特异性反应,而不能与疫苗免疫动物血清发生反应;在检测田间样品时,与3ABC-ELISA具有同样的特异性和敏感性 (P>  相似文献   

15.
Human plasma membrane-associated sialidase (Neu3) is one of several sialidases that hydrolyze sialic acids in the terminal position of the carbohydrate groups of glycolipids and glycoproteins. Neu3 is mainly localized in plasma membranes and plays crucial roles in the regulation of cell surface functions. In this study, we investigated the effects and molecular mechanisms of Neu3 on cell invasion and migration in vivo and in vitro. Initially, we found that the levels of Neu3 expression were higher in prostate cancer tissues and cell lines than in normal prostate tissues based on RT-PCR and Western blotting analyses. We then applied a Neu3 siRNA approach to block Neu3 signaling using PC-3M cells as model cells. Transwell invasion assays and wound assays showed significantly decreased invasion and migration potential in the Neu3 siRNA-transfected cells. RT-PCR and Western blotting analyses revealed that Neu3 knockdown decreased the expressions of the matrix metalloproteinases MMP-2 and MMP-9. In vivo, mice injected with PC-3M cell tumors were evaluated by SPECT/CT to determine the presence of bone metastases. Mice treated with attenuated Salmonella carrying the Neu3 siRNA developed fewer bone metastases than mice treated with attenuated Salmonella carrying a control Scramble siRNA, attenuated Salmonella alone or PBS. The results for bone metastasis detection by pathology were consistent with the data obtained by SPECT/CT. Tumor blocks were evaluated by histochemical, RT-PCR and Western blotting analyses. The results revealed decreased expressions of MMP-2 and MMP-9 at the mRNA and protein levels. Taken together, the present findings suggest that Neu3 is a promising molecular target for the prevention of prostate cancer metastasis.  相似文献   

16.
We have designed and constructed an inexpensive imaging system based on charge coupled device (CCD) technology and utilized it to demonstrate the sensitivity and rapid detection possible with Lumigen® chemiluminescent reagents. We also report the development of two new chemiluminescent reagents, Lumi-Phos® Plus and Lumigen PS. Lumi-Phos Plus is an ehanced formulation for the rapid detection of alkaline phosphatase on membranes and in solution. It provides excellent images in blotting applications with exposures of under a minute. Lumigen PS represents a new generation of peroxidase detection reagents. The wide dynamic range with excellent linearity, higher signal and lower background than other chemiluminescent reagents make Lumigen PS of unsurpassed value in enzyme-linked immunoassays and nuclic acid probe assays using HRP conjugates.  相似文献   

17.
In this study we investigated the relationship between thymidylate synthase (TS) protein expression, evaluated by Western blotting analysis and by immunohistochemistry (IHC), and growth rate in human colon xenograft tumors in nude mice. Human colon cancer cell lines were used to induce xenograft tumors and the tumor mass growth rate was calculated by measuring tumor size variations over time. TS 106 monoclonal antibody was used for both Western blotting and IHC TS detection. Tumor cell growth fraction was measured by Ki67/MIB1 immunolabeling and tumor cell growth rate by evaluating the mean nucleolar size in silver-stained sections. TS Western blotting values were related to tumor mass growth rate (p<0.001) and cell growth rate (p=0.002) but not to cell growth fraction (p=0.676). The degree of the IHC staining showed only a trend to be associated with TS protein expression measured on Western blotting, and was not related either to tumor mass growth or cell proliferation rate. Tumor xenografts were also characterized for TS promoter tandem repeat and p53 status. No relationship was observed between these variables and TS expression evaluated by both Western blotting and IHC analysis. Our results demonstrate that TS expression evaluated by Western blotting analysis is directly related to the tumor mass growth rate and question the use of the IHC approach to obtain precise quantitative information on TS expression in tumor samples.  相似文献   

18.
Western blotting is a commonly used technique in biological research. A major problem with Western blotting is not the method itself, but the use of poor quality antibodies as well as the use of different experimental conditions that affect the linearity and sensitivity of the Western blot. Investigation of some conditions that are commonly used and often modified in Western blotting, as well as some commercial antibodies, showed that published articles often fail to report critical parameters needed to reproduce the results. These parameters include the amount of protein loaded, the blocking solution and conditions used, the amount of primary and secondary antibodies used, the antibody incubation solutions, the detection method and the quantification method utilized. In the present study, comparison of ubiquitinated proteins in rat heart and liver samples showed different results depending on the antibody utilized. Validation of five commercial ubiquitin antibodies using purified ubiquitinated proteins, ubiquitin chains and free ubiquitin showed that these antibodies differ in their ability to detect free ubiquitin or ubiquitinated proteins. Investigating proteins modified with interferon-stimulated gene 15 (ISG15) in young and old rat hearts using six commercially available antibodies showed that most antibodies gave different semi-quantitative results, suggesting large variability among antibodies. Evidence showing the importance of the Western blot buffer and the concentration of antibody used is presented. Hence there is a critical need for comprehensive reporting of experimental conditions to improve the accuracy and reproducibility of Western blot analysis. A Western blotting minimal reporting standard (WBMRS) is suggested to improve the reproducibility of Western blot analysis.  相似文献   

19.
Normal sera contain a large number of naturally occurring autoantibodies which can mask important disease-associated ones. Western blotting has evolved as the most important tool to demonstrate autoantibodies in autoimmune diseases, because of its ability to simultaneous screening for a wide spectrum of different antigens. In previous studies we have shown the diagnostic potential of the analysis of autoantibodies in autoimmune diseases by means of multivariate statistics and artificial neural networks. However, the Western blotting procedure remains very time-consuming and is also limited in sensitivity. Therefore, we used an on-chip approach for the analysis of autoantibodies. This ProteinChip system uses ProteinChip arrays and SELDI-TOF MS (surface-enhanced laser desorption/ionization-time of flight mass spectrometry) technology for capturing, detection, and analysis of proteins without labelling or without the need of chemical modification. The microscale design of the arrays allows the analysis of very small quantities of proteins. In the present study, we used arrays with biologically activated surfaces that permit antibody capture studies. Protein-A-Chips were incubated with sera of patients (n = 12). After washing, the chips were incubated with a complex solution of autoantigens and subsequently washed again. If the Protein-A bound autoantibodies recognized their antigens, these proteins could be separated by their molecular masses and were to be detected by mass spectrometry. Previous studies using monoclonal antibodies have demonstrated that the detection limit is in the attomole level. Furthermore, all sera were analyzed by conventional Western blotting for direct comparison. In the present study, we have shown complex on-chip antibody-antigen reactions. At higher molecular weights (> 30 kDa) the detection sensitivity of this on-chip method was comparable to conventional Western blotting. At lower molecular mass, the Western blot technique is easily exceeded by the on-chip method. Considering that this on-chip procedure is quite easy to use, is much less time-consuming than Western blotting, and is much more sensitive at least in the low molecular weight range, the SELDI-TOF technology is a very promising approach for the screening of autoantibodies in autoimmune diseases. Due to its versatility, this on-chip technology could allow the large-scale screening for complex autoantibody distributions for diagnostic purposes and early detection of autoimmune diseases might be possible.  相似文献   

20.
建立一种新的基于链霉素沉淀的PrPSc的Western blot检测方法,用终浓度为60 mmol/L的链霉素处理蛋白酶K消化的PrPSc贮存液,通过离心沉淀PrPSc,用Western blot对PrPSc的链霉素富集效果进行检测.结果显示,链霉索能够与PrPSc结合形成高分子量复合物,但不影响糖基化形式.此外,基于链霉素沉淀的Western blot,无论是在低浓度或是大容积的条件下,均可显著地提高对PrPSc检测的敏感性.基于链霉素沉淀的Western blot试验是一种敏感、特异、快速及灵活的检测方法,有潜力用于脑组织、外周组织及体液中低水平的PrPSc的检测.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号