首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Liquid phase microextraction by back extraction (LPME-BE) combined with high performance liquid chromatography (HPLC)-fluorescence detection was developed for the determination of tramadol in human plasma. Tramadol was extracted from 2 mL of basic sample solution (donor phase) with pH 11.5 through a micro liter-size organic solvent phase (100 microL n-octane) for 25 min and finally into a 3.5 microL acidic aqueous acceptor microdrop with pH 2.5 suspended in the organic phase from the tip of a HPLC microsyringe needle for 15 min with the stirring rate of 1250 rpm. After extraction for a period of time, the microdrop was taken back into the syringe and injected into HPLC. Effected the experimental parameters such as the nature of the extracting solvent and its volume, sample temperature, stirring rate, volume of the acceptor phase, pH and extraction time on LPME-BE efficiency was investigated. At the optimized condition, enrichment factor of 366 and detection limit (LOD) of 0.12 microg L(-1) were obtained. The calibration curve was linear (r=0.999) in the concentration range of 0.3-130 microg L(-1). Within-day relative standard deviation RSD (S/N=3) and between-day RSD were 3.16% and 6.29%, respectively. The method was successfully applied to determine the concentration of tramadol in the plasma and urine samples and satisfactory results were obtained.  相似文献   

2.
Supported liquid membrane (SLM) technique for sample work-up and enrichment was used for determination of tricyclic antidepressant drugs in urine by high-performance liquid chromatography (HPLC) with UV detection. The studied antidepressant drugs were amitriptyline, opipramol, noxiptyline and additionally diethazine was used as possible internal standard. Alkaline phosphoric buffer with urine sample, as the donor solution, was passed over the liquid membrane into which investigated substances were extracted. On the other side of the membrane, analyzed compounds were trapped due to creating non-extractable form in acidic acceptor solution. Enriched and cleaned up drugs were then injected into a HPLC system with ultraviolet detection to analyze of their concentration in acceptor solution. Optimum extraction efficiency was determined by changing acceptor and donor solutions pH, application of different flow rates of donor solution and by using different solvents in the membrane. Also, donor solution volume, extraction time and concentration of analytes were varied to check the linearity of extraction process. The highest extraction efficiency: 43% for opipramol, 56% for noxiptyline, 43% for amitriptyline and 42% for diethazine (R.S.D. values were <6% and n=3) was achieved when 0.05 M phosphate buffer pH 4.0 and 9.5 were used as donor and acceptor solutions, respectively, n-undecane with 5% tri-n-octylphosphine oxide (TOPO) was used as liquid membrane. Limit of quantification (LOQ) for tricyclic antidepressants after enrichment of 100ml of urine sample was about 1 ng/ml.  相似文献   

3.
In the present work, the applicability of hollow fiber-based liquid phase microextraction (HF-LPME) was evaluated for the extraction and preconcentration of valerenic acid prior to its determination by reversed-phase HPLC/UV. The target drug was extracted from 5.0 mL of aqueous solution with pH 3.5 into an organic extracting solvent (dihexyl ether) impregnated in the pores of a hollow fiber and finally back extracted into 10 μ L of aqueous solution with pH 9.5 located inside the lumen of the hollow fiber. In order to obtain high extraction efficiency, the parameters affecting the HF-LPME, including pH of the donor and acceptor phases, type of organic phase, ionic strength, the volume ratio of donor to acceptor phase, stirring rate and extraction time were studied and optimized. Under the optimized conditions, enrichment factor up to 446 was achieved and the relative standard deviation (RSD) of the method was 4.36% (n = 9). The linear range was 7.5-850 μg L?1 with correlation coefficient (r2=0.999), detection limits was 2.5 μg L?1 and the LOQ was 7.5 μg L?1. The proposed method was evaluated by extraction and determination of valerenic acid in some Iranian wild species of Valerianaceae.  相似文献   

4.
In this paper, three phase-hollow fiber-based liquid phase microextraction (HF-LPME) combined with a HPLC procedure using diode array (DAD) and fluorescence detection (FLD) has been developed for the determination of four widely used sulfonamides: sulfadiazine, sulfamerazine, sulfamethazine, sulfamethoxazole and their main metabolites, the corresponding N(4)-acetyl derivatives: N(4)-acetyl-sulfadiazine, N(4)-acetyl-sulfamerazine, N(4)-acetyl-sulfamethazine, N(4)-acetyl-sulfamethoxazole. A Q3/2 Accurel KM polypropylene hollow fiber supporting 1-octanol was used between a 2 M Na(2)SO(4) aqueous solution (pH 4) as a donor phase and aqueous solution (pH 12) as an acceptor phase. The procedure allows very low detection and quantitation limits of 0.3-33 ng L(-1) and 0.9-100 ng L(-1), respectively. The proposed method was applied to the determination of the analytes in environmental water samples (surface, tap and wastewater).  相似文献   

5.
This work deals with the extraction and back-extraction of a recombinant cutinase using AOT reversed micelles in isooctane. The effect of pH, ionic strength, AOT concentration and temperature on the extraction and back-extraction of the cutinase was investigated. High extraction (97%) of the cutinase was achieved at pH 7.0 with a 50 mM Tris-HCl buffer solution containing 100 mM KCl, but a low activity was detected in the reversed micellar phase. At pH 9.0, cutinase was extracted (75%) to the reversed micelles with higher activity. Cutinase was recovered (50%) from a reversed micellar phase (100 mM AOT/isooctane) into a 50 mM Tris-HCl buffered solution at pH 9.0 with 100 mM KCl, and 20°C. Protein and cutinase activity global yields of 38 and 45%, respectively, were obtained for the global process, extraction and back-extraction steps, using low ionic strength, pH 9.0, 100 mM AOT and 20°C.Maria das Graças Carneiro da Cunha acknowledges a Ph.D. fellowship from Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) and Centro de Pesquisas Aggeu Magalhães, Brasil. This work was partly financed by the BRIDGE Programme (Contract BIOT-CT91-0274(DTEE)).  相似文献   

6.
Two-phase liquid-liquid extraction experiments were undertaken to study the enantioselective transport of the chiral N-protected α-amino acid derivatives from an aqueous buffer solution into an organic phase employing highly lipophilic carbamoylated quinine as chiral selector and phase transfer carrier, respectively. The chiral separation, derived from enantioselective ion-pair formation and differential solubility in the aqueous and organic phases of diastereomeric associates thus formed has been shown to be primarily dependent on the structure of the selectand, the nature of the organic solvent, the molar ratio of a given chiral selector to selectand in the two phases, and the pH of the aqueous phase. Extracted enantiomers were recovered by back-extraction using a relatively polar acidic medium in which the selector is barely insoluble. Thus, the enantiomeric purity of N-(3,5-dinitrobenzoyl)-leucine exceeded 95% enantiomeric excess with 70% overall yield with a single extraction and back-extraction step. Chirality 9:268–273, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

7.
A high-performance liquid chromatographic method using liquid-liquid extraction was developed for the determination of 1-(3-fluoro-4-hydroxy-5-mercaptomethyl-tetrahydrofuran-2-yl)-5-methyl-1H-pyrimidine-2,4-dione (l-FMAUS; I) in rat plasma and urine. A 100 microl aliquot of distilled water containing l-cysteine (100 mg/ml) was added to a 100 microl aliquot of biological sample. l-Cysteine was employed to protect binding between the 5'-thiol of I and protein in the biological sample. After vortex-mixing for 30s and adding a 50 microl aliquot of the mobile phase containing the internal standard (10 microg/ml of 3-aminophenyl sulfone), 1 ml of ethyl acetate was used for extraction. After vortex-mixing, centrifugation, and evaporating the ethyl acetate, the residue was reconstituted with a 100 microl aliquot of the mobile phase. A 50 microl aliquot was injected onto a C(18) reversed-phase column. The mobile phases, 50 mM KH(2)PO(4) (pH = 2.5):acetonitrile (85:15, v/v) for rat plasma and 50 mM KH(2)PO(4) (pH 2.5):acetonitrile:methanol (85:10:5, v/v/v) for urine samples, were run at a flow-rate of 1.2 ml/min. The column effluent was monitored by an ultraviolet detector set at 265 nm. The retention times for I and the internal standard were approximately 9.7 and 12.5 min, respectively, in plasma samples and the corresponding values in urine samples were 16.8 and 14.9 min. The quantitation limits of I in rat plasma and urine were 0.1 and 0.5 microg/ml, respectively.  相似文献   

8.
The behaviour of weak basic analytes in liquid-phase microextraction (LPME) and the optimisation of parameters in whole blood are described. Benzodiazepines and non-benzodiazepine drugs were chosen as model substances. Liquid-phase microextraction based on disposable polypropylene hollow fibres was used in the three-phase extraction of five weak bases from whole blood. The sample work up with the liquid-phase microextraction technique can be impeded by low recovery due to incomplete trapping in the acceptor phase of weakly basic drugs and the complexity of the whole blood matrix. Different parameters related to this problem were experimentally studied. Additionally the stability of the analytes was examined because of low pH in the acceptor phase. The investigation resulted in optimised LPME conditions for the extraction of weak bases from whole blood. The parameters limiting the recovery were evaluated.  相似文献   

9.
A supported liquid membrane technique was used for the extraction and enrichment of propofol in a spiked sample of urine. An acidic solution of propofol and thymol as an internal standard was passed over the membrane and after enrichment the acceptor solution was analyzed by LC with an electrochemical detector. The acceptor and donor pH, flow-rate, and volume of donor and different membrane solvents were varied to optimize the extraction efficiency. The detection limit for 100 ml of a spiked urine sample was 10 ppt of propofol.  相似文献   

10.
Tri-n-octylamine (TOA) is an effective extractant for the recovery of succinic acid from fermentation broth. The recovery of succinic acid from organic phase depends on the operating variables such as temperature, pH, volume of aqueous phase, and use of displacer. In thermal recovery of succinic acid, 34% of succinic acid was recovered at 90°C. More than 90% of succinic acid was back-extracted by pH-swing. Efficiency of back-extraction was increased 23% as increasing volume of aqueous phase. Use of oleic acid as a displacer increased efficiency of back-extraction to 76%. Aqueous phase volume and concentration of oleic acid were controlled simultaneously to increase the efficiency of back-extraction and percent recovery of succinic acid reached to 90.  相似文献   

11.
In this study, electromembrane extraction (EME) combined with cyclodextrin (CD)‐modified capillary electrophoresis (CE) was applied for the extraction, separation, and quantification of propranolol (PRO) enantiomers from biological samples. The PRO enantiomers were extracted from aqueous donor solutions, through a supported liquid membrane (SLM) consisting of 2‐nitrophenyl octyl ether (NPOE) impregnated on the wall of the hollow fiber, and into a 20‐μL acidic aqueous acceptor solution into the lumen of hollow fiber. Important parameters affecting EME efficiency such as extraction voltage, extraction time, pH of the donor and acceptor solutions were optimized using a Box‐Behnken design (BBD). Then, under these optimized conditions, the acceptor solution was analyzed using an optimized CD‐modified CE. Several types of CD were evaluated and best results were obtained using a fused‐silica capillary with ammonium acetate (80 mM, pH 2.5) containing 8 mM hydroxypropyl‐β‐CD as a chiral selector, applied voltage of 18 kV, and temperature of 20°C. The relative recoveries were obtained in the range of 78–95%. Finally, the performance of the present method was evaluated for the extraction and determination of PRO enantiomers in real biological samples. Chirality 26:260–267, 2014. © 2014 Wiley Periodicals, Inc.  相似文献   

12.
The back-extraction of proteins encapsulated in AOT reverse micelles was performed by adding a counterionic surfactant, either TOMAC or DTAB. This novel backward transfer method gave higher backward extraction yields compared to the conventional method with high salt and high pH of the aqueous stripping solution. The protein activity was maintained in the resulting aqueous phase, which in this case had a near neutral pH and low salt concentration. A sharp decrease of the water content was observed in the organic phase corresponding to protein back-extraction using TOMAC. The backward transfer mechanism was postulated to be caused by electrostatic interaction between oppositely charged surfactant molecules, which lead to the collapse of the reverse micelles. The back-extraction process with TOMAC was found to be very fast; more than 100 times faster than back-extraction with the conventional method, and as much as 3 times faster than forward extraction. The formation of 1:1 complexes of AOT and TOMAC in the solvent phase was observed, and these hydrophobic complexes could be efficiently removed from the solvent using adsorption onto Montmorillonite in order for the organic solvent to be reused. A second cationic surfactant, DTAB, confirmed the general applicability of counterionic surfactants for the backward transfer of proteins.  相似文献   

13.
Sensitive and selective determination of valproic acid in plasma by high-performance liquid chromatography (HPLC) is usually achieved with pre-column derivatization. In the present work, the derivatization is omitted due to using a simple but highly selective plasma extraction procedure and an optimized chromatographic condition. Valproic acid and the internal standard octanoic acid were extracted from plasma samples with n-hexane under acidic condition followed by back-extraction into diluted triethylamine. Chromatography was performed on a CN column (250 x 4.6 mm, 5 microm) under isocratic elution with acetonitrile-40 mM aqueous sodium dihydrogen phosphate (30:70, v/v), pH 3.5. Detection was made at 210 nm and analyses were run at a flow-rate of 1 ml/min. The method was specific and sensitive with a quantification limit of 1.25 microg/ml and a detection limit of 0.1 microg/ml in plasma. The mean absolute recovery for valproic acid using the present plasma extraction procedure was 75.8%. The intra- and inter-day coefficient of variation and percent error values of the assay method were all in acceptable range. Calibration curves were linear (r>0.999) from 1.25 to 320 microg/ml in plasma.  相似文献   

14.
15.
The application of supported liquid membrane (SLM) extraction for the enrichment of short peptides is presented. The extraction efficiency is dependent on the pH of donor phase and salt concentration in acceptor phase. Moreover, the extraction efficiency is also influenced by the peptide amino-acid sequence and hydrophobicity.  相似文献   

16.
A simple, sensitive, and inexpensive singe-drop microextraction (SDME) followed by gas chromatography and flame-ionization detection (GC-FID) was developed for determination of nicotine, anabasine, and cotinine in human urine and saliva samples. The target compounds were extracted from alkaline aqueous sample solution into an organic acceptor drop suspended on the tip of a 25-μL GC microsyringe in the aqueous sample solution. This microsyringe was also used for direct injection after extraction. Under optimized experimental conditions, calibration plots were found to be linear in the range of 0.5–25.0, 0.5–65.0, and 0.5–45.0 mg L?1 for nicotine, anabasines and cotinine, respectively. The method detection limit values were in the range of 0.33–0.45 mg L?1. Intra-day and inter-day precisions for peak area ratios were in the range of 1.3–9.2% and 2.0–7.0%, respectively. The proposed procedure was successfully applied to the determination of analytes in spiked urine and saliva samples with satisfactory results. The mean relative recoveries of spiked water samples ranged over 71.2–111.0%, with relative standard deviations varying from 2.3% to 10.0%.  相似文献   

17.
An assay was developed to determine concentrations of modafinil (dl-2-[(diphenylmethyl)sulfinyl]acetamide; Provigil) and its two major circulating metabolites, modafinil acid and modafinil sulfone, in human plasma. The assay utilized liquid-liquid extraction of the analytes and an internal standard, (phenylthio)acetic acid, from plasma into a mixture of hexane-dichloromethane-glacial acetic acid (55:45:2, v/v). The analytes were resolved isocratically on a narrow-bore phenyl column at a mobile phase flow-rate of 0.3 ml/min and were monitored by UV detection at 235 nm. The method reported herein reduces the required sample volume of previously reported methods from 1.00 to 0.200 ml of plasma while lowering the limit of quantification (LOQ). The linear range of the assay was from 0.100 to 20.0 microg/ml for each of the three compounds.  相似文献   

18.
A simple method for the quantification of tipranavir, the first non-peptidic HIV protease inhibitor, was developed and validated. Quinoxaline, as internal standard, was added to 50 microl of plasma before a liquid-liquid extraction by 600 microl of protein precipitation solution. The extracts were diluted before being injected in the chromatographic system. Chromatographic separation was made on a C18 column using potassium phosphate buffer (pH 3.2) and acetonitrile with gradient. Detection was performed by an UV detector at 260 nm. Relative error at three control quality concentrations ranged from -1.81 to 1.72%. Intra-day (CV%) and inter-day (CV%) precision ranged from 0.94 to 2.55% and from 3.07 to 4.24%, respectively. LOQ and LOD were 0.090 microg/ml and 0.035 microg/ml, respectively. Mean recovery was 87.1%+/-2.4%. Calibration curve was linear up to 180 microg/ml. Concentration range when optimized (0.703-180 microg/ml) proved to be adequate to measure tipranavir concentration in HIV-1-positive patients, therefore this method could be suitable for therapeutic drug monitoring of this drug.  相似文献   

19.
A method based on hollow fiber supported liquid membrane extraction coupled with a gas chromatograph equipped with flame ionization detector (GC-FID) was developed for the determination of six short-chain fatty acids including acetic acid, propionic acid, i-butyric acid, n-butyric acid, i-valeric acid and n-valeric acid in serum. Hollow fiber supported liquid membrane extraction was employed for preconcentration and clean-up of the samples. The fatty acids were extracted from the acidic donor (diluted serum) into a liquid membrane formed in the wall of the hollow fiber with 10% tri-n-octylphoshphine oxide (TOPO) in di-n-hexyl ether, and then extracted back into a basic acceptor solution filled in the lumen of the hollow fiber. After being acidified with HCl, the acceptor was directly analyzed by GC-FID. The acceptor concentration, donor pH, membrane liquid and extracting time were optimized giving an enrichment factor up to 155 times. The good linearity (r(2)>0.980), reasonable recovery (87.2-121%), and satisfactory intra-assay (8.2-11.5%) and inter-assay (6.1-11.6%) precision illustrated the good performance of the present method. Limits of detection (LOD) ranged from 0.04 to 0.24 microM and limits of quantification (LOQ) varied from 0.13 to 0.80 microM.  相似文献   

20.
A simple, sensitive and reproducible HPLC method is presented for the simultaneous determination of mycophenolic acid (MPA) and its metabolites phenolic MPA-glucuronide (MPAG) and acyl glucuronide (AcMPAG) in human plasma. Sample purification requires protein precipitation with 0.1 M phosphoric acid/acetonitrile in the presence of Epilan D as an internal standard (IS). Separation was performed by reversed-phase HPLC, using a Zorbax SB-C18 column, 32% acetonitrile and a 40 mM phosphoric acid buffer at pH 3.0 as mobile phase; column temperature was 50 degrees C, flow rate 1.4 ml/min, and measurement by UV detection was at 215 nm (run time 12 min). The method requires only 50 microl plasma. Detection limits were 0.1 microg/ml for MPA and AcMPAG, and 2.0 microg/ml for MPAG, respectively. Mean absolute recovery of all three analytes was >95%. This analytical method for the determination of MPA and its metabolites is a reliable and convenient procedure that meets the criteria for application in routine clinical drug monitoring and pharmacokinetic studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号