首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
d-Serine is an endogenous modulator of N-methyl-d-aspartate (NMDA) receptors. Plasma concentrations of d-serine and the ratio of d-serine to total serine may be used as clinically-translatable biomarkers in NMDA receptor-related disease. We developed a highly sensitive and specific method using high performance liquid chromatography tandem mass spectrometry (LC/MS/MS) for the simultaneous determination of the d- and l-isomers of serine in human plasma. Since d- and l-serine are endogenous components, phosphate buffered saline was used as the surrogate matrix. d- and l-serine in human plasma and PBS were treated by cationic exchange solid phase extraction. d-Serine (m/z 106.1 > 60.0), l-serine (m/z 106.1 > 60.1) and dl-serine-d3 (m/z 109.1 > 63.0) were detected using a multiple reaction monitoring. The enantiomer separation of d- and l-serine was successfully achieved without any derivatization step using tandemly-arranged and ice-cold CROWNPAK CR-I(+) columns with an isocratic mobile phase comprised of 0.3% trifluoroacetic acid in 10% acetonitrile. The standard curves were linear throughout the calibration range with 0.01–10 μg/mL (d-serine) and 0.1–100 μg/mL (l-serine), respectively. Intra-day and inter-day precision and accuracy of the quality control samples were within relative standard deviations of less than 15%. The endogenous concentrations of d- and l-serine in human plasma were 0.124–0.199 and 7.97–13.1 μg/mL, respectively.  相似文献   

2.
A microbore LC-MS/MS method is developed and validated for the quantification of the anti-epileptic drug oxcarbazepine (OXC) and its active metabolite 10,11-dihydro-10-hydroxycarbamazepine (MHD) in rat brain microdialysates, together with the internal standard for microdialysis probe calibration, 2-methyl-5H-dibenz(b,f)azepine-5-carboxamide (m-CBZ). The benefits of gradient versus isocratic separation are shown, next to the improved sensitivity resulting from the addition of 0.1% formic acid to the mobile phase. The coupling of microdialysis with ESI-MS requires sample desalting for which column switching was applied. Using weighed regression to calculate the calibration curves (1-1000 ng/mL), the assay was validated in terms of linearity, accuracy and precision, yielding a sensitive (limit of quantification is 1 ng/mL) and selective method for quantification of OXC, MHD and m-CBZ. By applying this method, we were able to determine the extracellular concentrations of OXC and MHD during at least 4h after intraperitoneal (i.p.) administration of 10 mg/kg OXC.  相似文献   

3.
Sensitive assay for determining plasma tenofovir concentrations by LC/MS/MS   总被引:1,自引:0,他引:1  
An LC/MS/MS assay for the determination of tenofovir (TNF) was developed and validated for use with the EDTA anticoagulated human plasma matrix. Heparin-treated plasma and serum matrices were also validated. After addition of adefovir as an internal standard, trifluoroacetic acid was used to produce a protein-free extract. Chromatographic separation was achieved with a Polar-RP Synergi, 2.0 mm x 150 mm, reversed-phase analytical column. The mobile phase was 3% acetonitrile/1% acetic acid, aq. Detection of TNF and the internal standard was achieved by ESI MS/MS in the positive ion mode using 288/176 and 274/162 transitions, respectively. The method was linear from 10 to 750 ng/ml with a minimum quantifiable limit of 10 ng/ml when 250 microl aliquots were analyzed. The usefulness of this LC/MS/MS method to routinely monitor plasma concentrations of TNF was demonstrated along with its ability to assist in the performance of pharmacokinetic studies.  相似文献   

4.
A liquid chromatography-mass spectrometry (LC/MS) assay method was developed for the quantification of PSC 833 in rat plasma, using amiodarone as internal standard (IS). Separation was achieved using a C(8) 3.5 microm (2.1 mm x 50 mm) column heated to 60 degrees C with a mobile phase consisting of acetonitrile-ammonium hydroxide 0.2% (90:10 v/v) pumped at a rate of 0.2 mL/min. Detection was accomplished by mass spectrometer using selected ion monitoring (SIM) in positive mode. An excellent linear relationship was present between peak height ratios and rat plasma concentrations of PSC 833 ranging from 10 to 5000 ng/mL (R(2)>0.99). Intra-day and inter-day coefficients of variation (CV%) were less than 15%, and mean error was less than 10% for the concentrations above the limit of quantification. The validated limit of quantification of the assay was 10 ng/mL based on 0.1 mL rat plasma. The method limit of detection, based on an average signal-to-noise (S/N) ratio of 3, was found to be 2.5 ng/mL. The assay was capable of measuring the plasma concentrations of PSC 833 in rats injected with a single dose of 5 mg/kg of the drug. PSC 833 and IS eluted within 4 min, free of interfering peaks. The method was found to be fast, sensitive, and specific for the quantification of PSC 833 in rat plasma.  相似文献   

5.
N-methyl-D-aspartate (NMDA) receptors, whose activation requires glycine site stimulation, play crucial roles in various physiological and pathological conditions in the brain. We investigated the regulatory roles of potential endogenous glycine site agonists, glycine and d-serine, in excitotoxic and ischemic cell death in the cerebral cortex. Cytotoxicity of NMDA on rat cerebrocortical slice cultures was potentiated by addition of glycine or d-serine. In contrast, cell death induced by oxygen/glucose deprivation (OGD) was not affected by exogenous glycine or d-serine, although blockade of NMDA receptors by MK-801 abolished cell death. In addition, higher concentrations of 2,7-dichlorokynurenic acid (DCKA), a competitive glycine site antagonist, were required to suppress OGD-induced cell death than those to suppress NMDA cytotoxicity. We also found that OGD triggered a robust increase in extracellular glycine. A glycine transporter blocker ALX 5407 increased the extracellular level of glycine, and the protective effect of DCKA against NMDA cytotoxicity was diminished in the presence of ALX 5407. Sensitivity of NMDA cytotoxicity to DCKA was also diminished by l-serine that increased the extracellular level of d-serine. These results indicate that both glycine and d-serine can act as endogenous ligands for NMDA receptor glycine site in the cerebral cortex, and that endogenous glycine may saturate the glycine site under ischemic conditions. The present findings are important for the interpretation of the mechanisms of NMDA and OGD cytotoxicity.  相似文献   

6.
d-Serine is a co-agonist of N-methyl-d-aspartate (NMDA) receptors. It has been implicated in the etiology of schizophrenia and has shown efficacy as an adjuvant to reduce positive and negative symptoms of schizophrenia. In addition, d-serine can modulate cognition in animals when administered alone. However, the neurochemical effects of exogenous d-serine on extra- and intra-cellular d-serine brain levels are poorly understood. In this study, we used both high performance liquid chromatography (HPLC) and enzyme-based microelectrode biosensors to quantify d-serine in the rat brain. We demonstrated levels of 2.3-2.8μM in the extracellular medium, 4μM in plasma and 188pmol/mg in brain tissue samples. An intraperitoneal (i.p.) d-serine injection (1g/kg) produced a slow increase in extracellular d-serine concentration in the cortex despite a surge in d-serine up to 13mM in the plasma, indicating poor diffusion through the blood-brain barrier. Using the respective volume fractions of blood, extracellular and intracellular spaces published in the literature, we estimated that d-serine intracellular stores represented more than 99% of total d-serine. These intracellular stores almost doubled 3h after d-serine administration. Overall, our data indicate that d-serine administration increases brain extra- and intra-cellular concentrations despite weak diffusion through the blood-brain barrier. These results pave the way for a better understanding of the neurochemical mechanisms by which d-serine administration modulates cognition.  相似文献   

7.
Proteolytic fragments of type II collagen, a major component of joint tissue, have recently been identified as biomarkers for osteoarthritis, a progressive disease associated with cartilage degeneration. A liquid chromatography/tandem mass spectrometry (MS/MS) assay that utilizes online immunoaffinity chromatography and column switching was developed in our laboratory for the neoepitope of type II collagen (NET2C). During method development, peptide collision-induced dissociation (CID) was found to be a significant source of assay variation, which exceeded 10% CV, despite the fact that a stable-isotope-labeled (SIL) internal standard was used to minimize imprecision. This phenomenon was studied in detail using peptides and associated SIL internal standards of varying lengths and amino acid compositions. Variability in peptide CID necessitated the monitoring of multiple MS/MS transitions to obtain acceptable assay precision. The assay was subsequently validated to measure NET2C concentrations in rat urine over the range of 0.1 to 10 ng/mL. The interday accuracy and precision ranged from 3.9 to 13.1 (%CV) and 10.7 to 5.3 (%RE), respectively, across the range of validated concentrations. A specific application of the assay is presented in which the role of estrogen deficiency in the development and progression of osteoarthritis was investigated. In this study, the effect of estrogen on lowering NET2C concentrations in urine in ovariectomized rats was demonstrated.  相似文献   

8.
A UPLC-MS/MS assay was developed and validated for simultaneous quantification of acetylcholine (ACh), histamine (HA), tele-methylhistamine (t-mHA), and tele-methylimidazolacetic acid (t-MIAA) in rat cerebrospinal fluid (CSF). The biological stability of ACh in rat CSF was investigated. Following fit-for-purpose validation, the method was applied to monitor the drug-induced changes in ACh, HA, t-mHA, and t-MIAA in rat CSF following administration of donepezil or prucalopride. The quantitative method utilizes hydrophilic interaction chromatography (HILIC) Core-Shell HPLC column technology and a UPLC system to achieve separation with detection by positive ESI LC-MS/MS. This UPLC-MS/MS method does not require extraction or derivatization, utilizes a stable isotopically labeled internal standard (IS) for each analyte, and allows for rapid throughput with a 4 min run time. Without an acetylcholinesterase (AChE) inhibitor present, ACh was found to have 1.9±0.4 min in vitro half life in rat CSF. Stability studies and processing modification, including the use of AChE inhibitor eserine, extended this half life to more than 60 min. The UPLC-MS/MS method, including stabilization procedure, was validated over a linear concentration range of 0.025-5 ng/mL for ACh and 0.05-10 ng/mL for HA, t-mHA, and t-MIAA. The intra-run precision and accuracy for all analytes were 1.9-12.3% CV and -10.2 to 9.4% RE, respectively, while inter-run precision and accuracy were 4.0-16.0% CV and -5.3 to 13.4% RE, respectively. By using this developed and validated method, donepezil caused increases in ACh levels at 0.5, 1, 2, and 4h post dose as compared to the corresponding vehicle group, while prucalopride produced approximately 1.6- and 3.1-fold increases in the concentrations of ACh and t-mHA at 1h post dose, respectively, compared to the vehicle control. Overall, this methodology enables investigations into the use of CSF ACh and HA as biomarkers in the study of these neurotransmitter systems and related drug discovery efforts.  相似文献   

9.
Ammonia neurotoxicity is associated with overactivation of N-methyl-d-aspartate (NMDA) receptors leading to enhanced nitric oxide and cyclic GMP synthesis and to accumulation of reactive oxygen and nitrogen species. Ammonia is detoxified in the brain via synthesis of glutamine, which if accumulated in excess contributes to astrocytic swelling, mitochondrial dysfunction and cerebral edema. This study was aimed at testing the hypothesis that the activity of the NMDA/NO/cGMP pathway is controlled by the ammonia-induced production of Gln in the brain. Ammonium chloride (final concentration 5 mM), infused for 40 min to the rat striatum via a microdialysis probe, caused a significant increase in Gln (by 40%), NO oxidation products (nitrite+nitrate = NOx) (by 35%) and cGMP (by 50%) concentration in the microdialysate. A Gln synthetase inhibitor, methionine sulfoximine (MSO, 5 mM), added directly to the microdialysate, completely prevented ammonia-mediated production of Gln, and paradoxically, it increased ammonia-mediated production of NOx and cGMP by 230% and 250%, respectively. Of note, MSO given alone significantly reduced basal Gln concentration in the rat striatum, had no effect on the basal NOx concentration, and attenuated basal concentration of cGMP in the microdialysate by 50%. The results of the present study suggest that Gln, at physiological concentrations, may ameliorate excessive activation of the NO–cGMP pathway by neurotoxic concentrations of ammonia. However, in view of potential direct interference of MSO with the pathway, exogenously added Gln and less toxic modulators of Gln content and/or transport will have to be employed in further studies on the underlying mechanisms. Special issue article in honor of Dr. Frode Fonnum. Wojciech Hilgier and Michal Węgrzynowicz contributed equally to this work.  相似文献   

10.
A robust and validated liquid-liquid extraction LC-MS/MS method was developed for population pharmacokinetic analysis and therapeutic drug monitoring of risperidone and the enantiomers of its major active metabolite (+)-and (-)9-hydroxyrisperidone in pediatric patients. The method was rapid, sensitive and used a low sample amount (200 microL), which is very desirable for the pediatric population. The assay was validated from 0.2 to 50 ng/mL in plasma for all analytes. LLOQ for all analytes was 0.2 ng/mL. The extracts were analyzed by normal phase LC-MS/MS. The sample run time was 8 min. Intra- and interday precision for all analytes was < or =6%; method accuracy was between 89 and 99%. Additional experiments were performed to analyze matrix effects and identify a proper internal standard for each analyte. The validated method was used to study risperidone and its enantiomer metabolites in plasma as part of a population pharmacokinetic study in pediatric patients with pervasive developmental disorder (PDD).  相似文献   

11.
A new liquid chromatography assay with isocratic elution and tandem mass spectrometry detection (LC-MS/MS) using an electrospray ionization interface in the multiple reaction monitoring mode was developed and validated for ertapenem determination in microdialysate samples. Linearity was demonstrated between 10ngmL(-1) (lower limit of quantification, LLoQ) and 160ngmL(-1). The precision (CV%) and accuracy (bias%) in microdialysates at the LLoQ were respectively 2.2% and 17.3% within-day and 10.6% and 2.7% between-days. Ertapenem was stable for 1 month at -20 degrees C and -80 degrees C but unstable at +4 degrees C. This new LC-MS/MS assay is simple, rapid and more sensitive than previously described assays.  相似文献   

12.
3-Nitrotyrosine (3NT) is used as a biomarker of nitrative pathology caused by peroxynitrite (PN), myeloperoxidase (MPO)-, and/or eosinophil peroxidase (EPO)-dependent nitrite oxidation. 3NT measurements in biological materials are usually based on either antibody staining, HPLC detection, or GC detection methodologies. In this report, a procedure is described for the measurement of 3NT and tyrosine (TYR) by LC-MS/MS that is simple, direct, and sensitive. Though highly specialized in its use as an assay, LC-MS/MS technology is available in many research centers in academia and industry. The critical assay for 3NT was linear below 100 ng/ml and the limit of detection was below 100 pg/ml. Regarding protein digested samples, we found that MRM was most selective with 133.1 m/z as the daughter ion. In comparison, LC-ECD was 100 times less sensitive. Basal levels of 3NT in extracted digests of rat brain homogenate were easily detected by LC-MS/MS, but were below detection by LC-ECD. The LC-MS/MS assay was used to detect 3NT in rat brain homogenate that was filtered through a 180 micron nylon mesh. Three fractions were collected and examined by phase contrast microscopy. The mass ratio (3NT/TYR) of 3NT in fractions of large vessel enrichment, microvessel enrichment, and vessel depletion was 0.6 ng/mg, 1.2 ng/mg, and 0.2 ng/mg, respectively. Ultimately, we found that the basal 3NT/TYR mass ratio as determined by LC-MS/MS was six times greater in microvessel-enriched brain tissue vs. tissue devoid of microvessels.  相似文献   

13.
Currently available radioimmunoassay methods for estradiol in serum lack sufficient sensitivity and precision to monitor estradiol levels in patients placed on third generation aromatase inhibitors. We recently validated a gas chromatography/tandem mass spectrometry assay (GC/MS/MS) for estradiol and determined estrogen levels in normal post-menopausal women and in women with breast cancer before and during administration of aromatase inhibitors. Validation of the GC/MS/MS assay in human plasma and human serum included determination of assay sensitivity (<0.63 pg/ml), precision (all CVs less than 17.8%), recovery (98-103%), and linearity of recovery (R=0.998). Levels of estradiol were lower when assayed by GC/MS/MS compared to RIA under all conditions (7.26+/-4.82 pg/ml versus 11.9+12.0 pg/ml in normal post-menopausal women; 5.88+/-3.43 pg/ml versus 13.8+/-7.5 pg/ml in breast cancer patients prior to treatment; and<0.63 pg/ml versus 5.8+/-4.1 pg/ml during aromatase inhibitor therapy). Fifty-five women treated either with atamestane/toremiphene or letrozole/placebo were monitored for estradiol levels at 4, 8 and 12 weeks of therapy. The mean levels of estradiol during aromatase inhibitor therapy was 5.8+/-4.1 pg/ml as measured by RIA and <0.63 pg/ml by GC/MS/MS. The degree of suppression with the aromatase inhibitors as detected by RIA was 58% versus >89% by GC/MS. These results suggest that most RIA methods detect cross-reacting estrogen metabolites and yield higher measured levels than GC/MS/MS. Several pharmacological and clinical considerations suggest that GC/MS/MS should become the preferred method for monitoring aromatase inhibitor therapy.  相似文献   

14.
Fungal infections occur in immunocompromised patients. Azole antifungal agents are used for the prophylaxis and treatment of these infections. The interest in therapeutic drug monitoring azole agents has increased over the last few years. Inter- and intra-patient variability of pharmacokinetics, drug–drug interactions, serum concentration related toxicity and success of therapy has stressed the need of frequently therapeutic drug monitoring of the drugs, belonging to the group of azoles. Therefore a simple, rapid and flexible method of analysis is required. This method is based on the precipitation of proteins in human serum with LC/MS/MS detection. Validation was performed according to the guidelines for bioanalytical method validation of the food and drug administration agency. The four most used azole drugs can be detected in human serum within the clinical relevant serum levels with good accuracy and reproducibility at the limit of quantification. Intra- and inter-day validation demonstrated good accuracy and reproducibility. A rapid, sensitive and flexible LC/MS/MS method has been developed and validated to measure voriconazole (VRZ), fluconazole (FLZ), itraconazole (ITZ) and posaconazole (PSZ) in human serum. This new method is suitable for clinical pharmacokinetic studies and routine monitoring in daily practice.  相似文献   

15.
Oxytocin (OT) is a neuropeptide with an extremely low endogenous level (low pg/ml) in human plasma. It is very challenging to develop a highly sensitive assay to measure endogenous OT, including radioimmunoassay (RIA) and enzyme-linked immunosorbent assay (ELISA). Electrospray ionization (ESI) liquid chromatography–tandem mass spectrometry (LC–MS/MS) can provide high-throughput and selective methods for quantification of peptides in biological samples. A novel and highly sensitive two-dimensional LC–MS/MS (2D-LC–MS/MS) assay combining solid-phase extraction (SPE) has been developed and validated for the determination of endogenous OT in both human and rat plasma. The lower limit of quantification (LLOQ) was 1.00 pg/ml for human and 50.0 pg/ml for rat. Human plasma diluted with water (1:6, v/v) was successfully optimized as a surrogate matrix for human to prepare standard curves without endogenous interference. The extraction efficiency and absolute recovery were above 65.8% using the HLB SPE procedure, and matrix effects were lower than 12%. The method was validated in the range of 1.00–250 pg/ml for human plasma and 50.0–10,000 pg/ml for rat plasma with precision less than 12.7% and accuracy less than 7%.  相似文献   

16.
d-Serine administration has been shown to be effective for the treatment of schizophrenia symptoms. However, d-serine must be administered at high doses to observe clinical effects. This is due in large part to d-serine undergoing oxidation by d-amino acid oxidase (DAAO) before it reaches the brain. Consequently, coadministration of d-serine with a DAAO inhibitor has been suggested as a way to lower the dose of d-serine required to treat schizophrenia. During the characterization of DAAO inhibitors as potential drugs, inhibitors are evaluated in rodents for their ability to increase plasma d-serine levels after oral coadministration. Current high-performance liquid chromatography (HPLC)-based methodologies to measure d-serine in plasma are time-consuming and are not amenable to concomitant analysis of multiple samples. We report the characterization of a 96-well format assay to monitor d-serine in plasma that greatly expedites analysis time. The assay involves the use of strong cation exchange solid phase extraction (SPE) to isolate d-serine from plasma followed by quantitation of d-serine using the DAAO-catalyzed reaction. Plasma d-serine determination using this assay could also be used as pharmacodynamic marker and as biomarker.  相似文献   

17.
A sensitive, stereoselective assay using solid phase extraction and LC-MS-MS was developed and validated for the analysis of (R)- and (S)-bupropion and its major metabolite (R,R)- and (S,S)-hydroxybupropion in human plasma and urine. Plasma or glucuronidase-hydrolyzed urine was acidified, then extracted using a Waters Oasis MCX solid phase 96-well plate. HPLC separation used an alpha(1)-acid glycoprotein column, a gradient mobile phase of methanol and aqueous ammonium formate, and analytes were detected by electrospray ionization and multiple reaction monitoring with an API 4000 Qtrap. The assay was linear in plasma from 0.5 to 200 ng/ml and 2.5 to 1000 ng/ml in each bupropion and hydroxybupropion enantiomer, respectively. The assay was linear in urine from 5 to 2000 ng/ml and 25 to 10,000 ng/ml in each bupropion and hydroxybupropion enantiomer, respectively. Intra- and inter-day accuracy was >98% and intra- and inter-day coefficients of variations were less than 10% for all analytes and concentrations. The assay was applied to a subject dosed with racemic bupropion. The predominant enantiomers in both urine and plasma were (R)-bupropion and (R,R)-hydroxybupropion. This is the first LC-MS/MS assay to analyze the enantiomers of both bupropion and hydroxybupropion in plasma and urine.  相似文献   

18.
Fipronil is an insecticide extensively used to treat pets, which has been identified as a potential thyroid disruptor in the rat. In this species, fipronil is mainly metabolized to fipronil sulfone and plasma concentrations of fipronil sulfone can be at least 20-fold higher than those of fipronil. Investigations of fipronil and fipronil sulfone exposure in blood remain sparse because of the lack of convenient and suitable analytical methods. We have developed and validated an LC/UV/MS/MS method to quantify both fipronil and fipronil sulfone within a wide range of concentrations in rat plasma. The double detection UV and MS coupled on-line enabled the concentrations to be measured over a 3 Log range (2.5–2500 ng/mL). The volume of sample required for the extraction by solid phase extraction was reduced to 75 μL with a recovery higher than 70%. The two-detection method agreement, evaluated with a Bland–Altman plot, was good for concentrations between 50 and 150 ng/mL. The method was applied to monitor plasma concentrations following a commonly used dosage regimen for the toxicological evaluation of fipronil in rats.  相似文献   

19.
A robust and simple method for absolute quantification of a novel bidirectional immunomodulatory drug candidate, cyclic thymic hexapeptide (cTP6), in rhesus monkey plasma was developed and validated by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Plasma proteins were precipitated by adding four volumes of acetonitrile. Peptides in the supernatant were separated by liquid chromatography on an Agilent Zorbax Eclipse Plus-C18 chromatographic column with gradient elution using 0.1% formic acid in water (mobile phase A) and 0.1% formic acid in methanol (mobile phase B) at 0.2 mL/min. The analytes were identified by triple quadrupole mass spectrometry in positive ion-mode. The assay was linear over a concentration range of 10-5000 ng/mL for cTP6, with a lower limit of quantification (LLOQ) of 10 ng/mL. Intra- and inter-day precision of the assay at three concentrations were 1.51-7.70% with accuracy of 95.1-104.2%. The average recovery of cTP6 for three concentration levels was 59.6-64.0%. No significant matrix effect was observed. Peptide cTP6 was detected in plasma of live rhesus monkeys up to 6-8h after intra-muscular injection. The half-life was 2.24-2.95 h. The result revealed a nonlinear pharmacokinetic response to increasing doses of cTP6 (100, 200, 500 μg/kg). For the multiple dose study of cTP6, the drug did not accumulate during daily administration at 100 μg/kg for 7 consecutive days in rhesus monkeys.  相似文献   

20.
Ultrafiltration of human plasma in combination with LC-MS/MS has been increasingly used in the quantitative analysis of the free fraction of drug candidates for PK/efficacy assessment. In addition to controlling the pre-incubation and centrifugation temperatures, some important factors that must be investigated and addressed include: (1) possible nonspecific binding, (2) possible impact of freeze/thaw cycles of plasma samples and extended storage of plasma samples at room temperature on the analyte recovery prior to ultrafiltration, and (3) identification of the appropriate assay dynamic range to avoid unnecessary dilutions. These factors were explored in the development and validation of a robust LC-MS/MS assay for the quantitative analysis of unbound vadimezan (ASA404) in human plasma. First, to mimic human physiological conditions, all plasma samples were incubated at ~37°C for a minimum of 30 min after thawing and prior to centrifugation to obtain the ultrafiltrate. Second, by passing the calibration standards and QC samples in plasma ultrafiltrate through the ultrafiltration membrane, the observed non-specific binding of the analyte due to the membrane was corrected. Third, the effects of multiple freeze/thaw cycles and/or storage at room temperature for various periods (4, 8, 16 and 24h) were evaluated to determine the impact on analyte concentrations in the ultrafiltrate from the plasma QC samples. Fourth, the appropriate dynamic range was established to accommodate the expected incurred sample free analyte concentrations. The validated assay has a dynamic range of 30.0-30,000 ng/ml for ASA404 in human plasma ultrafiltrate using a sample volume of 30 μl. Quality control pools containing the analyte were prepared at concentrations of 30.0-22,500 ng/ml to cover the assay calibration range. The intra-assay and inter-assay precision and accuracy were ≤ 15% (CV) and within ± 15% (bias) of the nominal values, respectively, for all measured QC concentrations, including the LLOQ. Freeze/thaw for up to three cycles of the plasma samples and/or the extended human plasma sample exposure to room temperature for up to 24h were confirmed to have no impact on the assay results for the free analyte. The validated method was successfully implemented to support clinical studies for the compound.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏