1.
BACKGROUND: The main concern in the long run of total hip replacements is aseptic loosening of the prosthesis. Optimization of the biomechanics of the hip joint is necessary for optimization of long-term success. A widely implementable tool to predict biomechanical consequences of preoperatively planned reconstructions still has to be developed. A potentially useful model to this purpose has been developed previously. The aim of this study is to quantify the association between the estimated hip joint contact force by this biomechanical model and RSA-measured wear rates in a clinical setting. METHODS: Thirty-one patients with a total hip replacement were measured with RSA, the gold standard for clinical wear measurements. The reference examination was done within 1 week of the operation and the follow-up examinations were done at 1, 2 and 5 years. Conventional pelvic X-rays were taken on the same day. The contact stress distribution in the hip joint was determined by the computer program HIPSTRESS. The procedure for the determination of the hip joint contact stress distribution is based on the mathematical model of the resultant hip force in the one-legged stance and the mathematical model of the contact stress distribution. The model for the force requires as input data, several geometrical parameters of the hip and the body weight, while the model for stress requires as input data, the magnitude and direction of the resultant hip force. The stress distribution is presented by the peak stress-the maximal value of stress on the weight-bearing area (p(max)) and also by the peak stress calculated with respect to the body weight (p(max)/W(B)) which gives the effect of hip geometry. Visualization of the relations between predicted values by the model and the wear at different points in the follow-up was done using scatterplots. Correlations were expressed as Pearson r values. RESULTS: The predicted p(max) and wear were clearly correlated in the first year post-operatively (r = 0.58, p = 0.002), while this correlation is weaker after 2 years (r = 0.19, p = 0.337) and 5 years (r = 0.24, p = 0.235). The wear values at 1, 2 and 5 years post-operatively correlate with each other in the way that is expected considering the wear velocity curve of the whole group. The correlation between the predicted p(max) values of two observers who were blinded for each other's results was very good (r = 0.93, p < 0.001). CONCLUSION: We conclude that the biomechanical model used in this paper provides a scientific foundation for the development of a new way of constructing preoperative biomechanical plans for total hip replacements.  相似文献   

2.
It was shown in several clinical studies that static one-legged stance may be a relevant body position to describe the loads acting at the hip. However, the stress distribution averaged during movement may better describe hip load than hip contact stress distribution in the static body position. Using data on the resultant hip force during walking taken from the measurements of Bergmann (2001), spatial distribution of contact stress over the articular surface was calculated by the HIPSTRESS method and compared with the stress distribution in one-legged stance. It is shown, that the shape of the contact stress distribution during one-legged stance closely resembled the averaged contact stress distribution during the walking cycle (Pearson's correlation coefficient R2 equals; .986; p < .001). This finding presents a link between the hypothesis that the averaged contact stress distribution during a walking cycle is crucial for cartilage development and the results of clinical studies in which the calculated distribution of contact stress in one-legged stance was successfully used to predict the clinical status of the hip.  相似文献   

3.
Abstract

The biomechanical parameters of the hip joint articular surface were analysed in 141 adult hips after Legg-Calve Perthes Disease, and 114 contralateral unaffected hips (controls), by using HIPSTRESS mathematical models. Geometrical parameters, assessed from anteroposterior and axial radiograms, were used as input to models for resultant hip force and contact hip stress. Results confirm previous indications that head enlargement after the Legg-Calve-Perthes Disease compensates the values of hip stress. Furthermore, it was found that an increased risk for coxarthritis development after the disease is secondary to concomitant hip dysplasia, with considerable and statistically significantly lower centre-edge angle and unfavourable distribution of stress.  相似文献   

4.
The main goal of this work was to develop an approached model to study dynamic behavior and prediction of the stress distribution in an in vitro Charnley cemented hip arthroplasty. An alternative version of the described pseudo-dynamic procedure is proposed by using the time integration Newmark algorithm. An internal restoring force vector is numerically calculated from the displacement, velocity, and acceleration vectors. A numerical model of hip replacement was developed to analyze the deformation of a dynamically stressed structure for all time steps. The experimental measurement of resulting internal forces generated in the structure (internal restoring force vector) is the second fundamental step of the pseudo-dynamic procedure. These data (as a feedback) are used by the time integration algorithm, which allows updating of the structure's shape for the next displacement, velocity, and acceleration vectors. In the field of Biomechanics, the potentialities of this method contribute to the determination of a dynamically equivalent in vitro stress field of a cemented hip prosthesis; implant fitted in patients with a normal mobility or practice sports. Consequences of the stress distribution in the implant zone that underwent cyclic fatigue loads were also discussed by using a finite element model. Application of this method in Biomechanics appears as a useful tool in the approximate stress field characterization of the peak stress state. Results show a peak value around two times the static situation, more for making possible the prediction of future damage and a programed clinical examination in patients using hip prosthesis.  相似文献   

5.
A dynamic nonlinear finite element model was developed to study juxtarticular stresses in the splinted rabbit knee, an established laboratory model for creating osteoarthrosis due to impulsive loading. Plane strain finite element results were validated by comparison with corresponding experimental data. Parametric effects studied included the input tibial displacement speed, the local bone density distribution, and the modulus of cartilage and subchondral bone. While the computed resultant contact force magnitude was sensitive to a number of model parameters, the stress patterns, when normalized to a given resultant force magnitude, were not. Despite comparable force peaks, the finite element results showed approximately six-fold higher effective strain rate levels for a severely impulsive loading protocol known to induce rapid osteoarthrosis, versus those for a mildly impulsive loading protocol not usually associated with cartilage damage. A propensity for elevated shear in the deep cartilage layer near the contact periphery, observed in nearly all computed stress distributions, is consistent with previous experimental findings of fissuring at that level in the impulsively loaded rabbit knee.  相似文献   

6.
This paper deals with the mechanical and electromyographic evaluation of the mechanism generating and transmitting the resultant leg extension force by maximal isometric contraction in two directions, the knee and hip joint being kept at 90 degrees. The two directions were a) from the center of gravity of the body to the ankle joint and b) from a point near the knee to the ankle. Six male subjects in a supine position exerted a maximal leg extension force of 47-112 kg for a) and 51-73 kg for b). These values were close to the smaller values of two forces estimated at the knee and at the hip from maximal isometric forces at the corresponding joint of the same joint angle. It was thus suggested that the joint limiting the resultant leg extension force was the knee for a) and the hip for b). The single joint muscles exhibited almost maximal activities when they concerned the joint which limited the resultant leg extension force. The double joint muscles were often contracted only moderately during the maximal isometric leg extension, indicating a different role of double joint muscles even at the maximal force production at a particular joint.  相似文献   

7.
A non-linear two-dimensional finite element model was used to study phenomena of stress redistribution in the natural adult hip resulting from parametric material property variations in the juxtarticular regions of the femoral head. Despite the geometrical simplifications employed, the intra-articular contact stresses (computed using the FEAP program) were found to be in reasonable qualitative agreement with previous in vitro data for the case of a normal hip. Generalized sclerotic changes in the subchondral plate, as reflected either in apparent modulus increases or in plate thickening, were found to have only minor effects on the computed contact stress distribution, although stress levels within the plate itself were markedly influenced. Localized subchondral plate sclerosis, by contrast, led to marked stress elevations in the cartilage immediately overlying the stiffened bone. Cartilage modulus increases caused increased load uptake for a given imposed deformation, but involved stress distribution increases which were very nearly linearly proportional to the increases in resultant load magnitude. Friction coefficient elevations had no noticeable effects on normal contact stress or upon overall load transmission, but involved complex, possibly slip-related, changes in intra-articular and cartilaginous shear stresses.  相似文献   

8.
A new method of computing the wear factor for total hip prostheses is presented. In the conventional method, only the resultant contact force and the track drawn by the point of its application are considered so that the product of the instantaneous force and sliding increment is integrated over one motion cycle. In the present, improved, method the contact pressure distribution is discretized by a large number of smaller normal forces, and the contribution of each is summed. This is important because the relative motion and contact pressure vary strongly with location, and because the transverse pressure component is substantial. Hence, the present surface integral represents the large contact surface better than the conventional line integral. A prerequisite for the surface integral was the method of computing the relative motion correctly anywhere on the contact surface, developed and published earlier by the present authors. For the pressure discretization, the contact surface was divided into nearly equal-sized surface elements. The contact pressure was modelled with ellipsoidal, paraboloidal and sinusoidal distributions. Two load cases were studied, double-peak and static. When an ellipsoidal contact pressure distribution extending over a hemisphere was discretized by 1000 element forces, the computed wear factor for double-peak load in a biaxial hip wear simulator was 30% lower than in the conventional resultant force case. The present method can be later developed further to involve the temporal variation of size and location of the contact surface.  相似文献   

9.
The mathematical models and the corresponding computer program for determination of the hip joint contact force, the contact stress distribution, and the size of the weight bearing area from a standard anteroposterior radiograph are described. The described method can be applied in clinical practice to predict an optimal stress distribution after different operative interventions in the hip joint and to analyze the short and long term outcome of the treatment of various pathological conditions in the hip. A group of dysplastic hips and a group of normal hips were examined, with respect to the peak contact stress normalized by the body weight, and with respect to the functional angle of the weight bearing area. It is shown that both these parameters can be used in the assessment of hip dysplasia.  相似文献   

10.
In order to increase the lifetime of the total hip endoprosthesis, it is necessary to understand mechanisms leading to its failure. In this work, we address volumetric wear of the artificial cup, in particular the effect of its inclination with respect to the vertical. Volumetric wear was calculated by using mathematical models for resultant hip force, contact stress and penetration of the prosthesis head into the cup. Relevance of the dependence of volumetric wear on inclination of the cup (its abduction angle ?A) was assessed by the results of 95 hips with implanted endoprosthesis. Geometrical parameters obtained from standard antero-posterior radiographs were taken as input data. Volumetric wear decreases with increasing cup abduction angle ?A. The correlation within the population of 95 hips was statistically significant (P = 0.006). Large cup abduction angle minimises predicted volumetric wear but may increase the risk for dislocation of the artificial head from the cup in the one-legged stance. Cup abduction angle and direction of the resultant hip force may compensate each other to achieve optimal position of the cup with respect to wear and dislocation in the one-legged stance for a particular patient.  相似文献   

11.

The mathematical models and the corresponding computer program for determination of the hip joint contact force, the contact stress distribution, and the size of the weight bearing area from a standard anteroposterior radiograph are described. The described method can be applied in clinical practice to predict an optimal stress distribution after different operative interventions in the hip joint and to analyze the short and long term outcome of the treatment of various pathological conditions in the hip. A group of dysplastic hips and a group of normal hips were examined, with respect to the peak contact stress normalized by the body weight, and with respect to the functional angle of the weight bearing area. It is shown that both these parameters can be used in the assessment of hip dysplasia.  相似文献   

12.
We have developed a mathematical model to calculate the contact stress distribution in total hip arthroplasty (THA) prosthesis between the articulating surfaces. The model uses the clearance between bearing surfaces as well as the inclination and thickness of the Ultra High Molecular Weight Poly-Ethylene (UHMWPE) cup to achieve this. We have used this mathematical model to contrast the maximal force during normal gait and during jogging. This is based on the assumption that the contact stress is proportional to the radial deformation of the cup. The results show that the magnitude of the maximal contact stress remains constant for inclination values in the range of [0-35 degrees ] and increase significantly with the cup clearance and liner thickness for inclination values in the range of [35-65 degrees ]. A major use for this model would be the calculation of spatial contact stress distribution during normal gait or jogging for different couples of bearing surfaces.  相似文献   

13.
The aim of the present study was to analyze the net joint moment distribution, joint forces and kinematics during cycling to exhaustion. Right pedal forces and lower limb kinematics of ten cyclists were measured throughout a fatigue cycling test at 100% of POMAX. The absolute net joint moments, resultant force and kinematics were calculated for the hip, knee and ankle joint through inverse dynamics. The contribution of each joint to the total net joint moments was computed. Decreased pedaling cadence was observed followed by a decreased ankle moment contribution to the total joint moments in the end of the test. The total absolute joint moment, and the hip and knee moments has also increased with fatigue. Resultant force was increased, while kinematics has changed in the end of the test for hip, knee and ankle joints. Reduced ankle contribution to the total absolute joint moment combined with higher ankle force and changes in kinematics has indicated a different mechanical function for this joint. Kinetics and kinematics changes observed at hip and knee joint was expected due to their function as power sources. Kinematics changes would be explained as an attempt to overcome decreased contractile properties of muscles during fatigue.  相似文献   

14.

Background

Sit-to-stand movements are a necessary part of daily life, and excessive mechanical stress on the articular cartilage has been reported to encourage the progression of osteoarthritis. Although a change in hip joint angle at seat-off may affect hip joint contact force during a sit-to-stand movement, the effect is unclear. This study aimed to examine the effect of the hip joint angle at seat-off on the hip joint contact force during a sit-to-stand movement by using a computer simulation.

Methods

A musculoskeletal model was created for the computer simulation, and eight muscles were attached to each lower limb. Various sit-to-stand movements were generated using parameters (e.g., seat height and time from seat-off to standing posture) reported by previous studies. The hip joint contact force for each sit-to-stand movement was calculated. Furthermore, the effect of the hip joint angle at seat-off on the hip joint contact force during the sit-to-stand movement was examined. In this study, as the changes to the musculoskeletal model parameters affect the hip joint contact force, a sensitivity analysis was conducted.

Results and conclusions

The hip joint contact force during the sit-to-stand movement increased approximately linearly as the hip flexion angle at the seat-off increased. Moreover, the normal sit-to-stand movement and the sit-to-stand movement yielding a minimum hip joint contact force were approximately equivalent. The effect of the changes to the musculoskeletal model parameters on the main findings of this study was minimal. Thus, the main findings are robust and may help prevent the progression of hip osteoarthritis by decreasing mechanical stress, which will be explored in future studies.
  相似文献   

15.
In this study, a three-dimensional finite element model of the human anterior cruciate ligament (ACL) was developed and simulations of passive knee flexion were performed. The geometrical model of the ACL was built from experimental measurements performed on a cadaveric knee specimen which was also subjected to kinematics tests. These experiments were used to enforce the particular boundary conditions used in the numerical model. A previously developed transversely isotropic hyperelastic material model was implemented and the ability to pre-stress the ligament was also included. The model exhibited the key characteristics of connective soft tissues: anisotropy, nonlinear behaviour, large strains, very high compliance for compressive or bending loading along the collagen fibres and incompressibility. Simulations of passive knee flexion were performed, with and without pre-stressing the ACL. The resultant force generated by the ACL was monitored and the results compared to existing experimental data. The stress distribution within the ligament was also assessed. When the ACL was pre-stressed, there was a good correlation between the predicted and experimental resultant forces reported in the literature over the entire flexion-extension range. The stress distribution in the pre-stressed and stress-free ACL were similar, although the magnitudes in the pre-stressed ACL were higher, particularly at low flexion angles.  相似文献   

16.
A practical and easy-to-use analysis technique that can study the patient's hip joint contact force/pressure distribution would be useful to assess the effect of abnormal biomechanical conditions and anatomical deformities on joint contact stress for treatment planning purpose. This technique can also help to establish the normative database on hip joint contact pressure distribution in men and women in different age groups. Twelve anatomic parameters and seven biomechanical parameters of the hip joint in a normal population (41 females, 15 males) were calculated. The inter-parameter correlations were investigated. The pressure distribution in the hip joint was calculated using a three-dimensional discrete element analysis (DEA) technique. The 3D contact geometry of the hip joint was estimated from a 2D radiograph by assuming that the femoral head and the acetabular surface were spherical in shape. The head-trochanter ratio (HT), femoral head radius, pelvic height, the joint contact area, the normalized peak contact pressure, abductor force, and the joint contact force were significantly different between men and women. The normalized peak contact pressure was correlated both with acetabular coverage and head-trochanter ratio. Change of abductor force direction within normal variation did not affect the joint peak contact pressure. However, in simulated dysplastic conditions when the CE angle is small or negative, abductor muscle direction becomes very sensitive in joint contact pressure estimation. The models and the results presented can be used as the reference base in computer simulation for preoperative planning in pelvic or femoral osteotomy.  相似文献   

17.
The effects of shear forces externally applied to the skin surface on the underlying tissues have been investigated. An analysis of the internal stresses and strains was conducted using a simplified model incorporating elasticity theory. Skin blood flow was measured using laser Doppler flowmetry while variable shear forces over a range of 0–250g were applied to the skin surface. The theoretical model predicts that the application of surface shear forces alters the internal stress distribution and makes the shear and compressive components of stresses increase ahead of the surface force application point. The force resulting from concomitant application of shear and normal force determines the internal maximum stress and strain. Theoretically, the shear force should have the same effects on the underlying tissues as normal force. The experimental investigations revealed that the skin blood flow decreased roughly linearly with the increase of shear forces. When a shear force equal to the normal force was applied, the flux decreased by 45%, nearly equal to the increasing magnitude (41%) of resultant of normal and shear forces.  相似文献   

18.
A three-dimensional musculoskeletal model of the lower limb was developed to study the influence of biarticular muscles on the muscle force distribution and joint loads during walking. A complete walking cycle was recorded for 9 healthy subjects using the standard optoelectronic motion tracking system. Ground contact forces were also measured using a 6-axes force plate. Inverse dynamics was used to compute net joint reactions (forces and torques) in the lower limb. A static optimization method was then used to estimate muscle forces. Two different approaches were used: in the first one named global method, the biarticular muscles exerted a torque on the two joints they spanned at the same time, and in the second one called joint-by-joint method, these biarticular muscles were divided into two mono-articular muscles with geometrical (insertion, origin, via points) and physiological properties remained unchanged. The hip joint load during the gait cycle was then calculated taking into account the effect of muscle contractions. The two approaches resulted in different muscle force repartition: the biarticular muscles were favoured over any set of single-joint muscles with the same physiological function when using the global method. While the two approaches yielded only little difference in the resultant hip load, the examination of muscle power showed that biarticular muscles could produce positive work at one joint and negative work at the other, transferring energy between body segments and thus decreasing the metabolic cost of movement.  相似文献   

19.
To facilitate the assessment of hip injury risk in frontal motor-vehicle crashes, an injury risk curve that relates peak force transmitted to the hip to the probability of hip fracture was developed by using survival analysis to fit a lognormal distribution to a recently published dataset of hip fracture forces. This distribution was parameterized to account for the effect of subject stature, which was the only subject characteristic found to significantly affect hip fracture force (X2(1)=6.03, p=0.014). The distribution was further parameterized to account for the effects of hip flexion and abduction from a standard driving posture on hip fracture force using relationships between mean hip fracture force and hip flexion/abduction reported in the literature. The resulting parametric distribution was used to define relationships between force applied to the hip and the risk of hip fracture for the statures associated with the small female, midsize male, and large male crash-test dummies, thus allowing these dummies to assess hip fracture/dislocation risk in frontal crashes, provided that such dummies are sufficiently biofidelic. For the midsize male crash test dummy, a 50% risk of hip fracture was associated with a force of 6.00 kN. For the small female and large male dummies, a 50% risk of hip fracture was associated with forces of 4.46 and 6.73 kN, respectively.  相似文献   

20.
The objective of this study was to construct a three-dimensional (3D) finite element model of the hip. The images of the hip were obtained from Chinese visible human dataset. The hip model includes acetabular bone, cartilage, labrum, and bone. The cartilage of femoral head was constructed using the AutoCAD and Solidworks software. The hip model was imported into ABAQUS analysis system. The contact surface of the hip joint was meshed. To verify the model, the single leg peak force was loaded, and contact area of the cartilage and labrum of the hip and pressure distribution in these structures were observed. The constructed 3D hip model reflected the real hip anatomy. Further, this model reflected biomechanical behavior similar to previous studies. In conclusion, this 3D finite element hip model avoids the disadvantages of other construction methods, such as imprecision of cartilage construction and the absence of labrum. Further, it provides basic data critical for accurately modeling normal and abnormal loads, and the effects of abnormal loads on the hip.  相似文献   