首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We describe optimized procedures for colorimetrically-detected DNA sequencing with direct blotting electrophoresis. One-step protocols for Sequenase and Klenow enzyme are given. The clapping technique has been adapted to allow convenient casting of very thin gels with an optimal lower gel (transfer) surface. This gives very sharp band patterns, enabling more than 350 bases from a single loading to be read with confidence. The crucial points for direct blotting electrophoresis are discussed. Background problems resulting from unspecific binding of streptavidin to the nylon membranes have been eliminated by the use of high concentrations of SDS in the incubation buffer; and using a single large glass tube for all incubation and washing steps is a very convenient and effective development protocol. Automation of the colorimetric development process is described.  相似文献   

2.
Direct blotting electrophoresis, a method designed to be of general application for the separation and electroblotting of macromolecules, has been adapted to produce protein blots suitable for subsequent processing by standard techniques such as dye staining or immunological detection. After their separation in a very short gel the protein bands are electrophoresed out of the gel onto an immobilizing matrix. The matrix which is moved across the bottom of the gel by a conveyor belt binds these proteins with high affinity. Once the protein samples have been loaded onto the gel and electrophoresis has been started, no further intervention is needed until the blot is completed. The total expenditure of time for such a direct blot is less than 4 h for a mixture of proteins in the molecular weight range of 14-70 kDa. The staining sensitivity of directly blotted proteins is about 200 ng protein per band as revealed by India ink staining.  相似文献   

3.
This study presents a mathematical approach that allows one to determine the shortest electrophoresis time and migration path length required for DNA sequencing. The calculation was applied to the capillary electrophoresis of a DNA sequencing separation and showed that acceptable resolution could be obtained using a shorter path length than anticipated.  相似文献   

4.
High speed DNA sequencing by capillary electrophoresis.   总被引:3,自引:4,他引:3       下载免费PDF全文
A major challenge of the Human Genome Initiative is the development of a rapid, accurate, and efficient DNA sequencing technology. A major limitation of current technology is the relatively long time required to perform the gel electrophoretic separations of DNA fragments produced in the sequencing reactions. We demonstrate here that it is possible to increase the speed of sequence analysis by over an order of magnitude by performing the electrophoresis and detection in ultra thin capillary gels. An instrument which utilizes these high speed separations to simultaneously analyze many samples will constitute a second generation automated DNA sequencer suitable for large-scale sequence analysis.  相似文献   

5.
Electrophoretic separation of oligonucleotides in denaturing polyacrylamide gels is primarily a function of length-dependent mobility. The 3' terminal nucleotide sequence of the oligonucleotide is a significant, secondary determinant of mobility and separation. Oligomers with 3'-ddT migrate more slowly than expected on the basis of length alone, and thus are better separated from the preceding, shorter oligomers in the sequencing ladder. Oligomers with 3'-ddC are relatively faster than expected, and are therefore less separated. At the 3' penultimate position, -dC- increases and -dT- reduces separation. Purines at the 3' terminal or penultimate positions of oligonucleotides affect separation less than the pyrimidines. These results suggest specific interactions among neighboring nucleotides with important effects on the conformation of oligonucleotides during electrophoresis. These interactions are compared to compression artifacts, which represent more extreme anomalies of length-dependent separation of oligonucleotides. Knowledge of base-specific effects on electrophoretic behavior of DNA oligomers supplements the usual information available for determination of sequences; additionally it provides an avenue to thermodynamic and hydrodynamic investigations of DNA structure.  相似文献   

6.
Rapid DNA sequencing by horizontal ultrathin gel electrophoresis.   总被引:3,自引:3,他引:3       下载免费PDF全文
A horizontal polyacrylamide gel electrophoresis apparatus has been developed that decreases the time required to separate the DNA fragments produced in enzymatic sequencing reactions. The configuration of this apparatus and the use of circulating coolant directly under the glass plates result in heat exchange that is approximately nine times more efficient than passive thermal transfer methods commonly used. Bubble-free gels as thin as 25 microns can be routinely cast on this device. The application to these ultrathin gels of electric fields up to 250 volts/cm permits the rapid separation of multiple DNA sequencing reactions in parallel. When used in conjunction with 32P-based autoradiography, the DNA bands appear substantially sharper than those obtained in conventional electrophoresis. This increased sharpness permits shorter autoradiographic exposure times and longer sequence reads.  相似文献   

7.
8.
Eukaryotic DNA Topoisomerase II (Topo II) has been studied using high-resolution two-dimensional polyacrylamide electrophoresis (2D-PAGE) and immunodetection of resolved proteins using specific antisera (Western blotting). Traditional methods of 2D-PAGE failed to resolve Topo II and neither nonequilibrium nor equilibrium pH gradients allowed Topo II to enter the first dimension gel. Exhaustive nuclease digestion and alternate protein solubilization strategies also produced negative results. We have developed altered first dimension pH gradient profiles and employed a more aggressive protein solubilization procedure which resulted in the resolution of Topo II. The 170-kDa polypeptide focuses with an apparent isoelectric point of approximately 6.5.  相似文献   

9.
Multiwavelength detection of laser induced fluorescence for dideoxynucleotide DNA sequencing with four different fluorophores and separation by capillary gel electrophoresis is described. A cryogenically cooled, low readout noise, 2-dimensional charge-coupled device is used as a detector for the on-line, on-column recording of emission spectra. The detection system has no moving parts and provides wavelength selectivity on a single detector device. The detection limit of fluorescently labeled oligonucleotides meets the high sensitivity requirements for capillary DNA sequencing largely due to the efficient operation of the CCD detector with a 94% duty cycle. Using the condition number as a selectivity criterion, multiwavelength detection provides better analytical selectivity than detection with four bandpass filters. Monte Carlo studies and analytical estimates show that base assignment errors are reduced with peak identification based on entire emission spectra. High-speed separation of sequencing samples and the treatment of the 2-dimensional electropherogram data is presented. Comparing the DNA sequence of a sample separated by slab gel electrophoresis with sequence from capillary gel electrophoresis and multiwavelength detection we find no significant difference in the amount of error attributable to the instrumentation.  相似文献   

10.
The progress of antisense DNA therapy demands development of reliable and convenient methods for sequencing short single-stranded oligonucleotides. A method of phosphorothioate antisense DNA sequencing analysis using UV detection coupled to capillary electrophoresis (CE) has been developed based on a modified chain termination sequencing method. The proposed method reduces the sequencing cost since it uses affordable CE-UV instrumentation and requires no labeling with minimal sample processing before analysis. Cycle sequencing with ThermoSequenase generates quantities of sequencing products that are readily detectable by UV. Discrimination of undesired components from sequencing products in the reaction mixture, previously accomplished by fluorescent or radioactive labeling, is now achieved by bringing concentrations of undesired components below the UV detection range which yields a 'clean', well defined sequence. UV detection coupled with CE offers additional conveniences for sequencing since it can be accomplished with commercially available CE-UV equipment and is readily amenable to automation.  相似文献   

11.
Practical DNA sequencing in a rugged capillary array electrophoresis system coupled directly to 96-well microtiter plates is demonstrated. A CCD detector was used to monitor all capillaries simultaneously with laser-induced fluorescence at 1.75 frames per second. The reconstructed electropherograms show good signal-to-noise ratios and resolution for the entire capillary array. The system used standard dye labeling and image splitting to obtain fluorescence intensities in two wavelength regions to allow calling up to 410 bases for the DNA sequence. The use of a replaceable poly(ethylene oxide) matrix and a protective poly(vinylpyrrolidone) coating allows high separation speed and short turnaround time for high throughput DNA sequencing. Critical evaluation of the system performance over repeated runs with base calling is presented.  相似文献   

12.
Capillary gel electrophoresis has been demonstrated for the separation and detection of DNA sequencing samples. Enzymatic dideoxy nucleotide chain termination was employed, using fluorescently tagged oligonucleotide primers and laser based on-column detection (limit of detection is 6,000 molecules per peak). Capillary gel separations were shown to be three times faster, with better resolution (2.4 x), and higher separation efficiency (5.4 x) than a conventional automated slab gel DNA sequencing instrument. Agreement of measured values for velocity, resolution and separation efficiency with theory, predicts further improvements will result from increased electric field strengths (higher voltages and shorter capillaries). Advantages of capillary gel electrophoresis for automatic DNA sequencing instruments and for genomic sequencing are discussed.  相似文献   

13.
A new technique for the detection of 32P-postlabelled DNA adducts separated by capillary electrophoresis was developed. By direct transfer from the capillary outlet to a positively charged moving filter paper, eluted radioactive peaks can be quantified using a phosphor imaging detector. With this method it is possible to separate DNA adducts from different carcinogens after 32P-postlabelling of the modified and unmodified nucleotides with high sensitivity approaching 1 adduct per 109 nucleotides.  相似文献   

14.
A new technique for the detection of 32P-postlabelled DNA adducts separated by capillary electrophoresis was developed. By direct transfer from the capillary outlet to a positively charged moving filter paper, eluted radioactive peaks can be quantified using a phosphor imaging detector. With this method it is possible to separate DNA adducts from different carcinogens after 32P-postlabelling of the modified and unmodified nucleotides with high sensitivity approaching 1 adduct per 109 nucleotides.  相似文献   

15.
DNA sequencing by capillary electrophoresis has been reviewed with an emphasis on progress during the last four years. The effects of sample purification, composition of sieving matrices, electric field strength, temperature, wall coating and DNA labeling on the DNA sequencing performance are discussed. Multicapillary array instrumentation is compared with one-capillary systems. Integrated systems that perform the whole DNA sequencing operation online starting from the DNA amplification through base calling and data processing are discussed.  相似文献   

16.
17.
The use of transposons offers the possibility of a directed approach to DNA sequencing, where a target DNA up to about 6kb in length can be sequenced quickly and with minimal redundancy. Transposons are mobile DNA elements which can be inserted in a reasonably random fashion into the target DNA. An important part of this process is the location of the transposon insertions (known as mapping) and the selection of a sensible subset of transposons to use as priming sites for sequencing reactions. This paper presents a probabilistic method of scoring selected subsets of transposons and a graph-theoretic algorithm for selection of a subset of maximal score.  相似文献   

18.
A simple system has been designed enabling ultrasensitive on-line detection of fluorescently labelled macromolecules, e.g. nucleic acids, proteins and peptides during electrophoretic separations in gels. An important application is the automated DNA sequence determination without radioactivity. Drying of gels, film exposure and handling are not necessary. A sulphydryl containing M13 sequencing primer has been synthesised and end-labelled in a reaction with fluorescein iodoacetamide. This is then used in the dideoxy reactions. In particular no moving parts or complicated software are required for data collection and analysis. Compared to our first automated device detection sensitivity has been improved by a factor of thirty to about 3 X 10(-18) mol per band. The resolution has increased to about 400 bases in 5 hours, with the possibility to read up to about 500 bases when they are properly labelled. Gels shorter than 20 cm may be used for resolution of about 300 bases. The single gel system may be upgraded for simultaneous running and reading of six or ten sequencing samples.  相似文献   

19.
A specific segment of mitochondrial DNA from 18 people was examined by two methods of direct DNA sequencing. This segment includes a small noncoding region (V) shown before by restriction analysis to exhibit length polymorphism. All 11 of the human mtDNAs previously reported to have a deletion in this region proved to lack one of the two adjacent copies of a 9-base-pair sequence normally present in human mtDNAs. Phylogenetic analysis suggests that this deletion occurred only once during the evolution of modern types of human mtDNA and that it will be a valuable anthropological marker for peoples of East Asian origin. The one human mtDNA reported to have an addition in region V differs from the wild type by two mutations in the first copy of the 9-base-pair sequence: one transition and an addition of four cytosines, thereby producing a run of 11 cytosines. One of the direct DNA sequencing methods uses a single oligonucleotide primer to facilitate dideoxy sequencing from purified mtDNA templates. The second, more successful, method first amplifies this mtDNA segment enzymatically with two flanking primers (the "polymerase chain reaction") and then uses a third primer for DNA sequencing. This latter method, which works on the DNA extracted from small amounts of blood as well as on purified mtDNA, is shown to be a rapid means of defining sequence variants without purifying and cloning the same DNA segment from many individuals.  相似文献   

20.
We examined the effect of an electric field strength gradient on DNA sequencing efficiency using capillary array electrophoresis. Several types of gradients were applied to DNA sequencing and tested in terms of read length and accuracy. Our original method improved the accuracy of DNA sequencing for longer fragments at high temperature.  相似文献   